}

Tender For Repair Maintenance Of Street Light Security Light Including Allied Work Under Allenby Ph Area Under Ge Utility Ambala Cantt, ambala-Haryana

Military Engineer Services-MES has published Tender For Repair Maintenance Of Street Light Security Light Including Allied Work Under Allenby Ph Area Under Ge Utility Ambala Cantt. Submission Date for this Tender is 17-04-2024. Electrical Maintenance Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42997428
Corrigendum : Tender For Repair Maintenance Of Street Light Security Light Including Allied Work Under Allenby Ph Area Under Ge Utility Ambala Cantt
Open Tender
Indian
Haryana
ambala
17-04-2024

Tender Details

Tender For Repair Maintenance Of Street Light Security Light Including Allied Work Under Allenby Ph Area Under Ge Utility Ambala Cantt; 1 Supply & Fixingin Replacement Of Integral Led Flood Light Luminaries 100 Watts Consisting Of Suitable Number Of Leds Andmounted On Mcpcb High Pressure Die Cast Aluminium Housing With Sealed Toughened Glass Cover With Secondary Optics Lens, Ip 66 Protection Suitable For Mast Light Mounting, 5700K, Led Efficiency >130 Lm / Watt And System Efficiency 110 Lm / W , 240 Volts Ac, 50 Hz, Cri>70% Operating Voltage Range 160 V-270 V, Power Factor> 0.95, Working Temperature Range -10ºc To 50ºc, Built In Surge Protection Of More Than 10 Kv , Confirm The Tests From Auth Labs :Lm79 & Lm 80, Incl Proper Fixing And Testing Of Flood Lights On 9 / 11 Mtr Long Steel Tubular Pole And Provide Facility Of Power Supply Shall Be Provide As Suitable For Maint Work Of Light Fittings Incl Make Proper Connection Of New And Existing Light Fittings Complete With Cutting , Welding , Drilling Holes, Nut Bolts, Washer Complete All As Specified & Directed. 2 All As Per Item Sr No 1 Here But For 150 Watts Led Luminaires Complete All As Specified & Directed 3 All As Per Item Sr No 1 Here But For 200 Watts Led Luminaires Complete All As Specified & Directed 4 Supply & Fixingin Replacement Ofled Street Light Fitting45 Watts Made Up Of Pressure Die Cast Aluminium Housing With High Efficiency Leds As Lighting Source And Lens Embedded Toughened Glass Having Top Opening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07 Consisting Of Suitable Number Of Leds With Sealed Toughened Glass Cover, 5700K, Led Efficiency >110 Lm / Watt And System Efficiency 110 Lm / W , 240 Volts Ac, 50 Hz, Cri>70% Operating Voltage Range 140 V-270 V, Power Factor> 0.95, Mains Current 0.270A, Working Temperature Range-10ºc To 50ºc, Built In Surge Protection Of More Than 10 Kv, Better Optics For Uniform Distrubution With Multiple Leds Not Less Than 2 Watt Each And Having Optical Grade Polycarbonate Lens With All Accessories , Suitable For Side Entry, Pole Mounting With Bracket Arm Od 40 Mm, Recommended Mounting Height With Suitable Inground Reinforcement Is 8 Mtrs, Confirm The Safety Test As Per Is 15885 Part-2 From Auth Labs :Lm79 & Lm 80, Incl Proper Fixing And Testing Of Street Lights On 9 / 11 Mtr Long Steel Tubular Poleincl Make Proper Connection Of New And Existing Light Fittings Complete With Cutting , Welding , Drilling Holes, Nut Bolts, Washer Complete All As Specified And Directed. Note :-Pvc Heavy Duty Conduit Pipe Along With 3 / 1 Run Of 1.5 / 2.5 Sqmm Pvc Insulated Unsheathed / Sheathed Copper Multistranded Conductor From Mcb Box To Streetshall Be Measured And Paidfor Separately. 5 All As Per Item Sr No 4 Here But For 70 Watts Led Luminaires Complete All As Specified And Directed. 6 All As Per Item Sr No 4 Here But For 90 Watts Led Luminaires Complete All As Specified And Directed. 7 Dismantling And Taking Down Security Light, Street Light, Hanger Light, Flood Light And High Mast Lights Of Any Type At Any Height Fittings Such Ashpsv / Hpmv / Mh / Led Light Of 48 Watt / 60 Watt / 70 / 72 Watt / 90 Watt / 120 Watt / 150 Watt / 200 Watt And 300 Watt Of Any Make Etc. Ac 230 Volts Any Wattage From Pole / Wall Roof Top / Hanger Roof Including Washing / Cleaning Of Perplex Cover Inspection For Location Of Faultand Replacing Of Defective Spare / Parts Required For Smooth Functioning, Tightening Of Electric Connection, Assembling And Reconnecting All As Per Site Requirment Complete All As Specified And Directed. Note: Defective Spare / Part Of Relevant Light Fitting Shall Be Measured And Paid Separately Under Relevant Item As Supply Only. 8 Supply Only Led Electronic Driver / Adaptor / Spdfor40-48 Watt Ledsecurity Light Fitting Of As Per Existing Makecomplete All As Specified & Directed. 9 Supply Only Led Electronic Driver / Adaptor / Spdfor60 Watt Ledsecurity Light Fitting As Per Existing Make Complete All As Specified & Directed. 10 Supply Only Led Electronic Driver / Adaptor / Spdfor70 / 72 Watt Ledsecurity Light Fitting As Per Existing Makecomplete All As Specified & Directed. 11 Supply Only Led Electronic Driver / Adaptor / Spdfor90 Watt Ledsecurity Light Fitting As Per Existing Makecomplete All As Specified & Directed. 12 Supply Only Led Electronic Driver / Adaptor / Spdfor 100 / 120 Watt Led Flood Light Fitting As Per Existing Makecomplete All As Specified & Directed. 13 Supply Only Led Electronic Driver / Adaptor / Spdfor150 Watt Ledflood Light Fitting As Per Existing Make Complete All As Specified & Directed. 14 Supply Only Led Electronic Driver / Adaptor / Spdfor200-300 Watt Ledflood Light Fitting As Per Existing Makecomplete All As Specified & Directed. 15 Labour Only For Trimming Of Tree Branches Oh Lines Of Ht / Lt & Maintain Approaching Minimum Clearance Of 3 Mtrfrom Branches. Proper Shutdown Will Be Taken And Maintained In The Register Complete All As Specified And Directed. 16 Supply & Fixing In Replacementof Automatic Street Light Control Switch With Infrared Sensor Based Nature Switch & Voltage Monitoring System ( Vms ) . Three Phase, 25 Amps Per Phase, Mcb Rating 32 Amp, Max Load 8-12 Kw Incl Circuit Copper Wire 10 Sq.Mm.Nature Switch Operation Should Be Based On Natural Light Lux Level. Required Illuminance Level For Switching On Is = 60 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 To Max. 12 Hrs. Vms Should Have Adjustable Over & Under Voltage Trip Level And Protection Against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & Vms Along With Suitable Power Contactor ( S ) And Incoming-Outgoing Mcbs Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. The Circuit Should Also Have Provision For Manual Operation ( I.E. By-Pass Option For Both Sensor ( Ns-02 ) And Vms ) . Madel :Swadeep-02Ec-8Kw3p-Vms Complete All As Specified And Directed.Note ( I ) S S Nut Bolts, Clamp For Fixing On Poles / Wall Are To Be Included In Quoted Rates. ( Ii ) The Sensor Must Have The Warranty Of Min Of 2 Years. ( Iii ) The Test Certificate And Warranty Certificate Must Be Provided By Supplier. ( Iv ) Cost Of Marking Description On The Box Is Included In Quoted Rate. 17 Supply & Fixing In Replacementof Automatic Street Light Control Switch With Infrared Sensor Based Nature Switch & Voltage Monitoring System ( Vms ) . Single Phase, 25 Amps Per Phase, Mcb Rating 40 Amp, Max Load 5-8 Kw Incl Circuit Copper Wire 10 Sq.Mm.Nature Switch Operation Should Be Based On Natural Light Lux Level. Required Illuminance Level For Switching On Is = 60 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 To Max. 12 Hrs. Vms Should Have Adjustable Over & Under Voltage Trip Level And Protection Against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & Vms Along With Suitable Power Contactor ( S ) And Incoming-Outgoing Mcbs Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. The Circuit Should Also Have Provision For Manual Operation ( I.E. By-Pass Option For Both Sensor ( Ns-02 ) And Vms ) . Madel : Swadeep-02Ec-5Kw1p-Vms Complete All As Specified And Directed.Note ( I ) Nut Bolts, Clamp For Fixing On Poles / Wall Are To Be Included In Quoted Rates. ( Ii ) The Sensor Must Have The Warranty Of Min Of 2 Years. ( Iii ) The Test Certificate And Warranty Certificate Must Be Provided By Supplier. ( Iv ) Cost Of Marking Description On The Box Is Included In Quoted Rate. 18 Excavation In Trenches Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre In Depth For Foundation, Shafts, Man Holes, For Under Ground Cable / Erection Of Poles, Stays, Locatingfault Of Lt Cable And Stay Assembly Etc Not Exceeding 10 Square Metre On Plan And Getting Out In Any Type Of Soil Including Dressing / Trimming Of Sides And Leveling, Grading And Ramming Of Bottom Of Excavation Complete All As Specified And As Directed. 19 All As Per Ser Item No 18.00 Here In Before But Depth Exceeding 1.5 Metre And Not Exceeding 3.0 Metre Complete All As Specified & Directed. 20 Returning, Filling In, Soil, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Each Layer Complete All As Specified And Directed. 21 Removing Excavated Material / Soil To A Distance Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed. 22 Material And Labour For Sand Cushioning To Cable With A Layer Of Sand 8 Cm Thick Before Laying The Cable And 15 Cms Thick After Laying The Cable ( Punned Down To 18 Cms Depth After Laying And Stretching Of Cable ) Complete All As Specified And As Directed. 23 Supply And Lay Bricks, Common Burnt Clay, Sub Class B, Old Size, Laid In Vertical Direction To Cable As Cable Protection Complete All As Specified And As Directed. 24 All As Per Ser Item No 23.00 Here In Before But Except Bricks, All As Specified And Directed.Note:- Old Bricks Retrieved From Ser Item No 28.00 To 35.00 Here In After Shall Be Re-Used. 25 Material & Labour For Cement Concrete In Foundations, Filling And Mass Concrete Pcc As Foundation To Poles, Type D2, 1:4:8 Using 40 Mm Graded Stone Agregate As Foundations To Poles Complete All As Specified And Directed. 26 Material & Labour For Cement Concrete, Filling And Mass Concrete, Pcc Type C2, 1:3:6 Using 20 Mm Graded Aggregate Complete All As Specified & Directed. 27 Material & Labour For Cement Concrete As Coping To Poles, Pcc Type B1, 1:2:4 Using 20 Mm Graded Stone Agregate As Foundations To Poles A Complete All As Specified & Directed. 28 Disconnecting & Taking Out Defective Underground Cable From Trenches, Pole, Pipe, Floor, Wall Etc And Locate The Fault, Rectify The Defect And Relaying The Xlpe Cable Underground Pvc Insulated And Overall Sheathed Aluminum Conductor Heavy Duty 1100 Volts Including Connecting And Testing For Any Size Complete All As Specified & Directed. ( Excavation / Earth Work & Sand Cushioning, Bricksandjoint Shall Be Measured & Paid For Separately ) . 29 Supply, Laying, Connecting And Testing Xlpe Underground Cable Insulated, And Overall Sheathed With Aluminium Conductor Heavy Duty 1100 Volts Grade10 Sqmm 4.0 Core Including Aluminium Thimbles Laid In Trenches / On Pole / Road Crossing Or Passing Through Existing / New Pipe Under Road Crossing Clamping On Wall Etc Including Taking Out Existing U / Scable Complete All As Specified & Directed.Note : ( I ) Earth Work, Sand, Bricks Removing, Returning Filling Will Be Paid Seperately. ( Ii ) Cost Of Laying Electrical Cable Through New / Existing Pipe Under Road, Buildings, Railway Tracks, Highways Are Incl In The Quoted Rates ( Iii ) All Equiments, Machinery Or Tool If Required For Laying Electrical Cable Through New / Existing Pipes Are Provided By The Contractor Without Any Extra Cost. 30 All As Per Item Ser No 29 Here In Before But For 4 Core 16 Sqmm Complete All As Specified & Directed. 31 All As Per Item Ser No 29 Here In Before But For 3.5 Core 25 Sqmm Complete All As Specified & Directed. 32 All As Per Item Ser No 29 Here In Before But For 3.5 Core 35 Sqmm Complete All As Specified & Directed. 33 All As Per Item Ser No 29 Here In Before But For 3.5 Core 50 Sqmm Complete All As Specified & Directed. 34 All As Per Item Ser No 29 Here In Before But For 3.5 Core 70 Sqmm Complete All As Specified & Directed. 35 All As Per Item Ser No 29 Here In Before But For 3.5 Core 95 Sqmm Complete All As Specified & Directed. 36 Supply And Fixing In Replacement Of Fabrication Of Kiosk Box Made Out Of Fibre Material Complete With Tpn , Aluminium Bus And Suitable For One Number Mcb ( Sp ) Including One No Mcb ( Sp ) 6 Amps 240 Volts With Glands For Incoming & Out Going Cable Including Fixing Of Flat Iron Clamps Of Size 20X4mm On Pcc / Steel Tubular Polecomplete All As Specified & Directed.. Make: Havells / Sintex. 37 Supply And Fix In Replacement Of Mcb Sp 6-32 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 38 Supply And Fix In Replacement Of Mcb Dp 16-40 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 39 Supply And Fix In Replacement Of Mcb Tpn 32-63 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 40 Supplying And Fixing In Replacement Of 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Metre Apart Including 4Mm Suspension Wire, One Twin Core Cable Flat Or Circular Of Size 10 Sqmm 2 Core Complete All As Specified And Directed. 41 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of 1100 Volts Grade Heavy Duty, Pvc Insulated Round 3 Core 1.0 Sqmm Copper Cable Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 42 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of 1100 Volts Grade Heavy Duty, Pvc Insulated Round 3 Core 2.5 Sqmm Copper Cable Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 43 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of Single Core Pvc Unsheathed Multi Stranded Copper Cable ( Frls ) 1.5 Sqmm Nominal Cross Sectional Area 1100 Volts Conforming To Is 694 Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 44 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of Single Core Pvc Unsheathed Multi Stranded Copper Cable ( Frls ) 2.5 Sqmm Nominal Cross Sectional Area 1100 Volts Conforming To Is 694 Including Electrical Connection Suitable Size Of Lugs, Nuts And Boltscomplete All As Specified And Directed. 45 Supply And Fixing In Replacement Of Rigid Non-Metallic Pvc Conduit Of Dia 20 Mm Exclusive Of Boxes ( Junction / Terminal ) But Inclusive Of All Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc Complete All As Specified & Directed.Note: Pvc Pipe Will Be Clamped At Three Position On Pole And Cost Of Clamp, Nut, Bolts Etc Are Incl In Quoted Rates Complete All As Specified And Directed. 46 Supplying And Fixing In Replacement Oflight Gradegalvanised Mild Steel Pipe 80Mm Bore With All Fittings, Laid Under Roads, Drain, Paths, Fixed To Poles / Walls With Suitablemild Steel Clamps, Bolts, Nuts And Washerscomplete All As Specified & Directed.. Note:- Excavation & Earth Work Shall Be Measured And Paidfor Separately Under Appropriate Item Of This Schedule. 47 All As Per Item No 46 Here-In-Before But Of Size 40 Mm Bore Complete All As Specified & Directed. 48 Supply & Fixingin Replacement Of Bracket Made Out Of Gi Tubing Single Piece Not Welded, Bended At Proper Angle Of Size 40Mm Dia, Light Grade 1.5 Mtr Long Including Painting With Aluminium Paint Over One Coat Of Red Oxide Primer To The Bracket Complete All As Specified And As Directed. 49 Supply & Fixing In Replacement Of Ms Clamp Suitable For Holding Street Light Bracket On Steel / Pcc Polemade Out Of 40 Mm X6 Mm Thick Flat Iron With M.S Nuts Bolts 50 Mm Long 10 Mm Dia-3 Nos With Flat Washer 3Mm Thick -02 No For Each Includingpainting With Aluminium Paint Over One Coat Of Red Oxide Primer To The M.S Clamps Complete All As Specified & Directed. 50 Supply, Fix And Erection Of Prestressed Concrete Pole 9.0 Mtr Long In True Vertical Position 102X172 Mm At Top 102X279 Mm At Bottom Class-10 Incl Providing Black And White Strips With Synthetic Enamel Paint 30 Cm Each Alternate Upto 1.5 Mtr Including 2 Bands Of Radium Tape Of 2 Width Greeen & Red Colour Above The Coping Of Pole Starting With Black Strip Including Dismantalling And Taking Down Old Unsv Pole Complete All As Specified & Directed.. Note ( I ) Earth Work And Pcc Shall Be Measured And Paid Seperately ( Ii ) Description As Per Direction Of Engineer-In-Charge Will Be Printed On Each Pole Without Any Extra Cost. 51 Supply, Fix Anderection Of Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts And Screws As Specified Type 410 Sp-31, 09 Meter Long, Providing Synthetic Enamel Aluminium Paint Over One Coat Of Red Oxide And Black And White Strips With Synthetic Enamel Paint 30 Cm Each Alternatively Upto 1.5 Mtr Including 2 Bands Of Radium Tape Of 2 Width Greeen & Red Colour Above The Coping Of Pole Starting With Black Strip, Including Dismantalling And Taking Down Old Unsv Pole Complete All As Specified & Directed.. Note ( I ) Earth Work And Pcc Shall Be Measured And Paid Seperately ( Ii ) Description As Per Direction Of Engineer-In-Charge Will Be Printed On Each Pole Without Any Extra Cost. 52 Supply And Fix Inreplacementof Lithium Based Energy Efficient Integrated Solar Street Light Of 32 Watt” In Single Frp Body With Duly Polyurethane Coating ( Camouflage Color ) , Encases With Monocrystalline Solar Pv Panel Of 64 / 66Wp , Lithium Battery 11.1 / 12.8V, 33.0Ah With Inbuilt Bms, Ip 65, High Brightness W-Led ( 160-180Lm / Watt ) Lamp With Aluminum Reflector For Better Light Distribution , Cri >70, Color Temperature 5700°K - 6500°K, Microcontroller Based Charge Controller Cum Driver, Automatic Dimming Function ( First Four Hours At Full Brightness & Rest Of The Time At Lower Light Level With Pir Motion Sensor ) , Dusk To Dawn Operation, Suitable To Working Temperature: ( - ) 10°C To ( + ) 55°C, Weight Not More Than 16-18Kg With Adjustable Ms Clamp Suitable For Pole / Wall Mounting Etc Complete As Required. Protections: Short Circuit, Overload, Reverse Polarity And Battery Protections. Firm Should Provide Vital Parameters Test Report From Nabl Accredited Lab And Should Be Of Made In India With Ce & Rohs Compliant Including Tubular Pole 6 Mtr Height With Bottom Base Plate 200X200x12 Mm , Outdoor Dia Not Less Than 65 Mm With Heavy Duty Gi Pipe Or Steel Thickness 3Mm And Suitable Arrangement To Mount Solar Light As Directed On Pole Including Foundation Pcc 1:3:6 Type C-1Using 20Mm Graded Crushed Stone Aggregate And Erection As Per Manufacturer Drawing, Providing Synthetic Enamel Aluminium Paint Over One Coat Of Red Oxide Primer Complete All As Specified And Directed Make:- Axxon ( Axn-32W ) Or Equivalent Of Phillips / Bajaj / Wipro / Havells 53 Dismantling And Taking Down Old Unsv Lt Feeder Pillar And Supply, Installing, Testing & Commissioning In Replacement Of Outdoor Type Cubical Lt Feeder Pillar Panel Box Size 1.0Mx0.8Mx50cm With Double Door Type Cubical Panel Board Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front And Rear Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Openable By Keyshaving Chromium Plated 19 Mm Dia Fancy Lock, “U” Type Gasket Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Aluminium Bus Bar Of 200 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :-A ) Incoming Mccb100 Amps, 16 Ka 4 Pole 415 Volts Ac, -01 No. ( B ) Outgoing Mccb63 Amp, 10 Ka, 4 Pole 415 Volt Ac, -02 Nos. ( C ) Outgoing Mcb32 Amp, 10 Ka , Tpn 415 Voltac -02 Nos ( D ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( E ) Digital Ammeter Of Range 0-200 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( F ) Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( G ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 54 Dismantling And Taking Down Old Unsv Lt Feeder Pillar And Supply And Installing, Testing & Commissioningin Replacement Of Factory Fabricated Outdoor Type Feeder Pillar Board Of Size 1.0Mx0.8Mx0.50 Mtr , Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Door01 No Of Pad Lock Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coated Painting After 7-Tank Pre Treatement Control & Power Wiring With Suitable Size Of Copper Conductor Along With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb 160 Amps Tpn, 25 Ka -01 No ( B ) Mccb 40Amp Tpn 4 Pole - 04 Nos ( C ) Aluminium Busbar Of Capacity 200 Amps With Colour Coated Heat Shrinkable Sleeve And Suitable Hole For Out Going Connection - Set Of Four. ( D ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates 55 Notes For Item Sr No.53 To 54 ( I ) The Quoted Rate Shall Include Minor Items Such As Lugs, Nuts & Bolts, Washers, Top Insulators, Sleeves, Provision Of Extra Holes In Bus Bar Etc. ( Ii ) All Internal Wiring Shall Be Done With Suitable Size Of Pvc Insulated Solid Copper Conductor Frls Cable Conforming Tois-694. ( Iii ) Panel Drawing Shall Be Got Approved Before Placing Of Orderfrom Engr-In-Charge / Ge. ( Iv ) The Bus Connection For Cable From Main Bus Bar To Outgoing Mccb Will Be Connected Through Suitable Rating Bus Bar Strip Type Duly Insulated. ( V ) Cable Will Be Entered In Panles Through Gland. ( Vi ) Cost Of Marking Description And Matter On The Front Door As Specified And Directed By Engr-In-Charge Is Incl In Quoted Rate. 56 Material And Labour In Replacement Of Broken Earth Pit Of Size 300X300x300 Mm Madeof Pcc 1:2:4 Type B1 Using 20 Mm Graded Crushed Stone Aggregate, And Earth Pit Cover Made Out Of Rcc 1:2:4 Type B1, Cover Reinforced With 8 Mm Dia Tmt Bars @ 100 Mm Centre To Centre Both Ways With Handle Made Out Of 8 Mm Dia Bar, Watering Arrangement With Funnel And Wire Mesh And Including Reconnecting Of Earth Lead Of Any Type With New Nuts, Bolts And Washers As Required At Site With Testing Result Complete All As Specified & Directed.. 57 Material And Labour In Replacement Of Stay By Tightening Of Stay Wire After Untying The Conductor Spans From The Poles To Make Correct Tensions And Maintain Verticality Of Poles, Including Re-Jointing The Conductors In Position With New Binding Wire Complete All As Specified & Directed.. 58 Repairing Of Existing Unserviceable Pcc Coping Of Lt / Ht Pole By Breaking Completely And Material And Labour For Pcc 1:2:4 Type B1, ( Using 20Mm Graded Crushed Stone Aggregate ) Of Size 600X600x300mm Including Form Work And Applying Two Coats Of White Wash Complete All As Specified & Directed.. 59 Dismantling Andtaking Down Old U / S Earthing Andmaterial And Labour For Earthing Complete With Galvanized Steel Plate Earth Electrode 60Cmx60cmx6mm Thick Surrounded By Char Coal And Salt Buried Directly In Ground Vertically In Pit Of Depth Not Less Then 2.25 Mtr Below Ground Level With Top Edge Of The Earth Plate At Depth Of Not Less Than 1.5 Mtr Below Ground Level Surrounded From All Sides By Char Coal Dust And Common Salt In Alternate Layers Of 15 Cm Depth And Earth Plate Electrode Connected To Galvanised Earth Lead Wire Of 4.0 Mm Dia By Means Of Gi Nuts Bolts, Check Nuts And Washers And Connected To Earthing Test Point Drawn Through 15 Mm Bore Gi Pipe Medium Grade For Protection Of Gi Earth Lead Wire Including 20Mm Bore Gi Pipe Medium Grade For Watering Gi Funnel Pcc Earth Pit ( 1:3:6 ) Type C-2 With Ci Frame And Rcc Cover All As Shown In Electrical Plate No 3 On Ssr Part - I Including Testing Complete All As Specified And As Directed.Note : ( I ) The Quoted Rate Shall Include The Cost Of Earth Work, Gi Pipe For Watering, Gi Protection Pipe, Funnel, Wire Mesh, Rcc Cover, Etc. Complete. Rcc Cover Shall Be 50Mm Thick In 1:2:4 Type B-1 Using 8Mm Bars @10Cm C / C Both Way. ( Ii ) The Quoted Rate Shall Include The Cost Of The Earth Pit Covers To Be Conspicuously Marked Of Plate With Standgrouted In Pcc. ( Iii ) On Testing After Completion If The Desired Earth Resistance Ismore Than 2? The Earthing Will Be Redone At No Extra Cost 60 Supply And Fixing In Replacement Mccb Tpn 315 / 320 Amps, 415 Volts, 36 Ka, 4 Pole , Ics=100% Icu, Overload Adjustable Short Circuit Adjustable Type Incl Spreader Link And Complete Connection Complete All As Specified & Directed.. 61 Supply And Fixing In Replacement Mccb Tpn 200 Amps, 415 Volts, 25 Ka, 4 Pole , Ics=100% Icu, Overload Adjustable Short Circuit Adjustable Type Incl Spreader Link And Complete Connection All As Specified And Directed. 62 Supply And Fixing In Replacement Mccb Tpn 160 Amps, 415 Volts, 25 Ka, 4 Pole , Ics=100% Icu, Incl Spreader Link And Complete Connection All Asspecified And Directed. 63 Supply And Fixing In Replacement Mccb Tpn 630 Amps, 415 Volts, 36 Ka, 4 Pole , Ics=100% Icu, Incl Spreader Link And Complete Connection All As Specified And Directed. 64 Material And Labour For Detecting Of Fault In Cable Ht / Lt With Fault Locator Equipment Supplying Of Ht / Lt Electric Supply ( 11 Kv / 430 Volts ) To Make The Ht / Lt Cableserviceablewith Straight Throughjoint Of Size 70-300 Sqmm.Notes: ( A ) The Ht Fault Which Is Detected Through Cable Fault Locator Will Only Be Paid Under This Item. ( B ) Transportation Charges Of Cable Fault Locator And Dg Set Deemed To Be Included In The Quoted Rate. ( C ) Earth Fault Locator Will Be Provided By The Contractor For Even Single Ht Fault And No Delay On This Account Will Be Acceptable Otherwise Penalty Will Levied Rs 500.00 Per Hour. ( D ) Straight Through Joint , 95 To 300, Sqm, Labour Charges, Excavation And Making Joint Deemed To Be Including In Quoted Rate. 65 Supply And Fixing In Replacement Lt Line Separators 1100 V Grade Pvc Spacer To Separate Lt Conductor From Each Other 5 Line As Per Is Complete All As Specified & Directed. 66 Supply And Fixing In Replacementlt Line Separators 1100 V Grade Pvc Spacer To Separate Lt Conductor From Each Other 4 Line As Per Is Complete All As Specified & Directed. 67 Supply And Fix In Replacement Of Air Circuit Breaker, Fixed Type, Spring Operated, Manually Tpn, 4 Pole, 800 Amp, 415 Volts With Thermal Magnetic Release, ( O / L, S / C, E / F Protection & Confirming To Iec-60947-2& 3 Rated Breaking Capacity And Making Capacity 50 Ka Short Time Current Complete All As Specified & Directed. 68 Supply And Fix In Replacement Of Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled Red, With Letters, Figures And Conventional Skull And Bones In Signal White Colour And Fixed With M.S. Clamps, Bolts And Nuts Of Approved Size, For Lt, 20X15cm Size Complete All As Specified And Directed 69 Material & Labour Chemical Spray ( Dc 2.26 Contact Cleaner ) In Container Of 415 Ml / 300G For Precision Blended Multipurpose Product For Prevents Corrosion Penetrates, Lubricants, Displaces And Seals Out Moisture Release Rusted Mechanisum Cleanese Etc Complete All As Specified & Directed.. 70 Material And Labour Inreplacementofaluminium Terminals ( Thimbles ) After Cutting The Worn Out / Faulty Cable End From Lt Pillar / Panel Box Including Necessary Earth Work For Taking Out The Cable From Loop Line, Returning, Filling In And Making Cable Lead By Providing Aluminium Lugsincluding Crimping With Crimping Tools In The Existing Lt Cable 25 Sqmm 4 Core Upto 50 Sqmm Including Necessary Connectioncomplete All As Specified & Directed. 71 All As Per Item Ser No 69 Here In Before But Size Of Lt Cable 70 Sqmm 3.5 Core Upto 120 Sqmm 3.5 Core Complete All As Specified & Directed. 72 All As Per Item Ser No 69 Here In Before But Size Of Lt Cable 150 Sqmm 3.5 Core Upto 300 Sqmm 3.5 Core Complete All As Specified & Directed. 73 Material And Labour For Shifting Heavy Items / Excavation / Cleaning Areas / Cleaning Site By Providing Crane / Hydra / Excavators / Tractors / Trolley Etc As Required At Site Complete All As Specified And Directed. 74 Material & Labour For Drilling Hole Of Any Size Manually As Per Site Requirement, Drilling For Laying Pipes Under The Road For Crossing Electrical Cable Complete All As Specified & Directed. 75 Material & Labourfor Spraying Herbicide ( Round Up ) On Area To Remove Unwanted Vegitation / Grass At Various Locations Complete All As Specified & Directed. 76 Supply And Fixing In Replacement Of On Load Change Over Switch With Sheet Steel Enclosure 415 V, 4 Pole, 630 Amps Capacity Fixed On Walls / Ms Frame / Pole / Lt Panel For Electric Supply Distribution Between Main And Dg Set Incl Necessary Connection Of Cable From Lt Panels To Change Over Switches Complete All As Specified & Directed.. 77 Taking Down Old Unserviceable Indicator Lamp Any Type Any Colour And Supply And Fixing New Indicator Red / Yellow / Green Including Making Electrical Connection With Suitable Size Of Copper Lugs Duly Crimped Complete All As Specified & Directed. 78 Re-Streching Of Loose Over Head Acsr Conductor Of Any Type / Gi Wire And Repair Of The Broken Conductors Andaddingnew Length ( If Required ) In Placeof Old And Burnt Conductor Of Any Size On Existing Poles With Proper Sagging Including Winding With Winding Wire All As Specified.Old Conductor Shall Be Reused Where Required For Repairing Broken Length Of Conductor Complete All As Specified & Directed.Note:- Each Run Of Conductor Will Be Measured And Paid Seperately. 79 Supply And Fixing In Replacement Of Sensor Of Nature Switch Operation Should Be Based On Natural Light Lux Level, Required Illuminance Level For Switching On Is <30 Lux And For Switching Off >10 Lux , The Sensor Should Also Have Part Night Operation Facility Of Min 4 Hrs To Max 12 Hrscomplete All As Specified And Directed Make:- Swadeep , Model Nature Switch -02 ( Sensor ) Or Equivalent As Approved By Ge. 80 Supply And Fixing In Replacement Of Contactor Three Pole 18 Amp In Street Light Timer Box Coil Operating Voltage 230 Volt Complete All As Specified And Directed Make- Bch / L&T Or Equivalent As Approved By Ge 81 Supply And Fixing In Replacement Of Contactor Two Pole 25 / 40 Amp In Street Light Timer Box Coil Operating Voltage 230 Volt Complete All As Specified And Directed Make- L&T / Bch Or Equivalent As Approved By Ge 82 Supply And Fixing In Replacement Ofcontactor Coil ( 230V ) For Mu Series 25 / 40 Amps 2 Pole Contactorscomplete All As Specified And Directed Make- L&T ( Cat No Cs90793 ) Or Equivalent As Approved By Ge 83 Supply And Fixing In Replacement Ofcontactor Coil ( 240V ) For Freedom Series 18 Amps 3 Pole Contactorscomplete All As Specified And Directed Make- Bch, Cat No Ce15d1n-K Or Equivalent As Approved By Ge 84 Supply And Fixing In Replacement Ofvms ( Voltage Monitoring Series ) In Street Light Timer Box, Including All Salient Features Such As Selectabe Under / Over Voltage Trip Levels, Protection Against Phase Loss & Natural Loss, Protecotion Against Phase Reversal And Phase To Phase Unbalance ( 10% ) , Voltage Sensing Principle And Led Indications For Power And Fault Conditions Complate All As Specified And Directed Make- L&T, Cat No Sm500 Or Equivalent Of Gic 85 Material And Labourforaluminium Conductor Steel Reinforced ( Acsr ) Conductor Of Size Isi Marked For Lt Over Head Lines On Poles Including Stretching, Tightining Of Poles Insulator With Winding Wire Of Suitable Size With Insulator / Strechingof Acsr Conductor Including Dismantling And Taking Down Old Unserviceable Acsr Conductor Incl Cutting, Welding Complete All As Specified & Directed. 86 Material And Labour For Vibratory Compactive, Precast Cement Concrete Rubber Moulded, Coloured ( Except Grey Colour ) , Interlocking Designer Paver Blocksin Milano Shape, Comfirming To Is-15658-2006 Of 60 Mm Thickness, M-35 Grade, As In Path, Hardingstanding, Etc Laid Over And Including 25 Mm Compacted Sand Cushioning, Including 75 Mm Thick Pcc 1:4:8 Type D-2 Using 40Mm Graded Crushed Stone Aggregate Including Surface Excavationover Area N. Exc. 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil And Removing Excavated Soil Exc. 50 Mtr But N. Exc. 250 Mtr Includig Demolition Of Existing Paver Blocks, Complete All As Specified & Directed. 87 Earthing Complete With Galvanisedearth Plate Electrode 600Mm X 600Mmx 6.00Mm Thick Surrounded By Charcoal And Salt, Buried Directly In Ground Vertically In A Pit Of Depth Not Less Than 2.25M Belowground Level With Top Edge Of The Earthplate Not Less Than 1.5M Belownormal Groundlevel, Connected To 25X4 Mm Gi Strip Earth Lead By Means Of Bolts, Nuts, Checks Nut And Washers Made Out Of Galvanized Iron Or Steel, Earth Wire Protected By Galvanized Steel Pipe 40Mm Bore Medium Grade And Connected To Main Switch Or Main Control Board All As Shown In Electrical Plate No.3 Of Ssr Part-I & Including Necessary Excavation And Earth Work. The Rate Also Include Charcoal & Salt In Alternate Layers, 20Mm Bore Gi Pipe Medium Grade For Watering And 40Mm Bore Giprotection Pipe ( Light Grade ) , Funnel, Wire Mesh, Cast Iron Cover Andframe Etc, Complete, All As Specified Or Indicated And As Directed Including Testing On Completion Including Dismantalling Of Old U / S Earthing Complete All As Specified And Directed.Note : ( I ) The Quoted Rate Shall Include The Cost Of Earth Work, Gi Pipe For Watering, Gi Protection Pipe, Funnel, Wire Mesh, Rcc Cover, Etc. Complete. Rcc Cover Shall Be 50Mm Thick In 1:2:4 Type B-1 Using 8Mm Bars @10Cm C / C Both Way. ( Ii ) The Quoted Rate Shall Include The Cost Of The Earth Pit Covers To Be Conspicuously Marked Of Plate With Standgrouted In Pcc. ( Iii ) On Testing After Completion If The Desired Earth Resistanceis More Than 2?The Earthing Will Be Redone At No Extra Cost 88 Supply And Fixing In Replacement Indoor / Outdoor End Termination Joint Heat Shrinkable 1100 Volts For Xlpe Cable Of Size 3.5 / 4.0 X 10-50 Sqmm Including Complete All As Specified & Directed. 89 Supply And Fixingin Replacement Indoor / Outdoor End Termination Joint Heat Shrinkable 1100 Volts For Xlpe Cable Of Size 3.5 X 70-120 Sqmm Including Complete All As Specified & Directed. 90 Dismantling And Taking Down Old Unsv Lt Panel And Supply, Installing, Testing & Commissioning Outdoor Type Cubical Panel Board Of Size 1.2Mx1.0Mx.5M, Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front And Back Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Both Doors Incl 2 No. Of Pad Locks Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Copper Bus Bar Of 400 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb400 Amps, 50 Ka 4 Pole 415 Volts Ac, Adjustable Type, ( Incoming ) -01 No. ( B ) Mccb125 Amp, 415 Volt, 4 Pole, Breaking Capacity 25 Ka , Adjustable Type ( Outgoing ) -04 Nos. ( C ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( F ) Digital Ammeter Of Range 0-500 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( G ) Digital Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( H ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 91 Dismantling And Taking Down Old Unsv Lt Panel And Supply, Installing, Testing & Commissioning Outdoor Type Cubical Panel Board Of Size 1.2Mx1.0Mx.5M, Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform Block Type 60 Cm Above Ground Level And 30 Cm Grouting In Ground, Frame Factory Fabricated With Front And Back Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Both Doors Incl 2 No. Of Pad Locks Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Copper Bus Bar Of 400 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb315 Amps, 36 Ka 4 Pole 415 Volts Ac, Adjustable Type, ( Incoming ) -01 No. ( B ) Mccb100 Amp, 415 Volt, 4 Pole, Breaking Capacity 16 Ka , ( Outgoing ) -04 Nos. ( C ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( D ) Digital Ammeter Of Range 0-500 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( E ) Digital Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( F ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 92 Receiving / Recording Complaints Under Allenby Line Power House Of Perimeter / Security / Street Lights To Comprehensive Maintenance By Attendng Daily Complaints Including Sunday And Other Holidays For 08 Hrs And Making The Same Serviceable In All Respects Alongwith Replacement Of Any Major Part But Including Small Length Of Cable ( Not More Than 20 Mtr ) , Adhesive Tape And Other Connected Minor Accessories Shall Also Include To Visual Inspection. Quoted Rate Also Include Excavation Offaulty Cable Below The Pole And Making Seviceable With Accessories Of All Nature Like Faulty Light, Faulty Insulator, Broken Conductor & Cable Fault, Burnt Out Mcbs, Isolators, Switch Fuses, Service Cables Etc Sector `C-2`Areacomplete All As Directed To The Entire Satisfaction Of Engineer-In-Charge.Note ‘A’ :- ( I ) Any Complaint Left Unattended By The Electrician Shall Be Communicated To The Je In-Charge / Age E / M With Reason. No Charge Shall Be Paid For The Complaint Per Day Till The Complaint Is Resolved. ( Ii ) New Material / Stores Provided For Completing The Job Shall Be Measured And Paid For Separately Under Relevant Items Of Boq. ( Iii ) Contractor Shall Provide All Type Of T&P Of Lt Network, Bamboo Ladder ( 23 Feet ) With Safety Gloves To Electrician For Attending The Street Light Complaints ( Iv ) Contractor Shall Provide The Complaint Register 200 Pages – 10 No, Complaint Book With 100 Slips- 20 No. Booklets Serially Numbered In Triplicate. ( V ) Contractor Shall Provide 01 No. Experienced Electrician Having Minimum 5 Years Experience ( 01X 08 Hrs Per Day ) And 01 No. Helper Having Minimum 2 Years Experience ( 01 X 08 Hrs Per Day ) Including Sundays And Holidays To Attend The Complaints. ( Vi ) The Contractor Shall Provide Insurance Cover Of Minimum Rs 5 Lakh Per Head Under Ie Rules 2003 And Minimum Wages Act. ( Vii ) The Electrician And Helper Will Be Interview By Je E / M / Engr-In-Charge For Verification Of Experience, Character And Sound Mind And Body. ( Viii ) Cost Of Materials For Replacement Of Lights, Mcbs, Pole Junction Box, Brackets, Clamps, Insulator And Jumper Shall Be Measured And Paid Separately Under Relevant Items As Material & Labour. 93 Supply, Fixing And Testing Of Auto Day / Night On And Off Photocell.Ldr Sensor Switch 06 Amps For Lighting On And Off Photocell, Ldr Sensor Switch 6Amps For Lighting On And Off Water Proof 220Volt 50Hz, Ac Supply, Model No Quick Sense Qs-301 Complete With All Accessories Internally Pre-Wired Including Connection With 1.5Sqmm Copper Conductor From Main Supply To Sensor, Sensor To Fittings Including Taking Down Existing Complete All As Specified & Directed.. 94 Supply, Fixing And Testing Of Auto Day / Night On And Off Photocell.Ldr Sensor Switch 10 Amps For Lighting On And Off Photocell, Ldr Sensor Switch 6Amps For Lighting On And Off Water Proof 220Volt 50Hz, Ac Supply, Model No Quick Sense Qs-301 Complete With All Accessories Internally Pre-Wired Including Connection With 1.5Sqmm Copper Conductor From Main Supply To Sensor, Sensor To Fittings Including Taking Down Existing Complete All As Specified & Directed.. 95 Note:-Amount Of Credit Ofrs. 105485.00 For Retrieved Materials Is Mentioned In Schedule Of Credit Of Tender Documents In Pdff Form Which Will Be Deducted Offline While Acceptance Of Tender.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Mar-2024 AMENDMENT BOQ 10-04-2024
2 10-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
INR 46 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail