Repair / Replacement Of Worn Out Lt Panel Of Dg And Bus Bars Changeover Switch, Electric Cable And Connected Items In Tech Area At Af Stn Leh Under Ge ( Af ) Leh, Leh-Jammu And Kashmir

Military Engineer Services-MES has published Repair / Replacement Of Worn Out Lt Panel Of Dg And Bus Bars Changeover Switch, Electric Cable And Connected Items In Tech Area At Af Stn Leh Under Ge ( Af ) Leh. Submission Date for this Tender is 16-04-2024. Cushioning Supplies Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42990249
Corrigendum : Repair / Replacement Of Worn Out Lt Panel Of Dg And Bus Bars Changeover Switch, Electric Cable And Connected Items In Tech Area At Af Stn Leh Under Ge ( Af ) Leh
Open Tender
Indian
Jammu And Kashmir
Leh
16-04-2024

Tender Details

Repair / Replacement Of Worn Out Lt Panel Of Dg And Bus Bars Changeover Switch, Electric Cable And Connected Items In Tech Area At Af Stn Leh Under Ge ( Af ) Leh- 1 Material And Labourweather Proof Outdoor Bus Bar Chamber Cum Lt Panel, Made Out Of 3.12 Mm Thick Ms Sheet With Front & Rear Opening, Powder Coated, Dust & Vermin Proof, Ip-66 Protection Comprising4 Nosaluminium Strips Each Of 200 Amps, 60Cm Longhaving 10Cm Min Distance From The Body, Duly Insulated Mounted On Epoxy Insulators In Horizontal Position In Stepped Manner With 4 No’S Mounting Legs Made Out Of 40Mm X 40Mm X 6Mm Angle Iron Grouted In Pcc Block ( 30Cm Depth Below Ground Level And 60Cm Above Ground Level ) In Cement Concrete 1:3:6, Type C-2 ( Using 40Mm Grade Crushed Stone Aggregate ) , Andconnections With Size Of Aluminium Thimbles, Nuts, Bolts & Washers Including Cable Glands At Entry And Outlet Points With One Mccb Of 160 Amps 16 Ka, 4 Pole As Incomer Of The Bas Bar With Taking Down The Existing All Cables, Dressing The Cable Properly With Lugs, Nuts, Bolts Washer Etc. & Refixing The Same Including Excavation And Earth Work, Returning Filling And Removal Of Surplus Soils Complete All As Specified And Directed By Engr-In-Charge. 2 Taking Down Old Unserviceable Lt Panel And Supply, Fixing, Connecting And Commissioning Of Lt Panel, Factory Made ( Cpri Approved ) , Indoor / Outdoor Type ( Kiosk ) , Floor Mounted, Compartment Type, Dust And Vermin Proof ( Ip-55 Protection ) Suitable For 415 Volts Grade, 3 Phase, 4Wire 50Hz Ac Supply With 400 Amp Aluminium Bus Bar Tpn, Colour Coded & Sleeved, Fabricated Out Of 3.15 Mm Thick Mild Steel Crca Sheet Mounted On 50Mmx50mmx6mm Angle Iron Frame And Welded To 75Cm Long 50Mmx50mmx6mm Size Angle Iron Legs ( 04 Nos ) , Front & Rear Openable, With Front Hinged Double Door Inclusive Locking Arrangement With Provision Of Allincoming / Outgoing Cable Entries Alongwith Suitable Size Double Compression Type Cable Glands And Adopter Boxes For Incoming And Outgoing Cable & Spray Painting With Two Coats Of First Quality Super Enameled Grey Paint Over And Including A Coat Of Red Oxide Primer, Including Anti-Corrosive Treatment ( 7 Tank ) , Legs Grouted In Floor In Pcc ( 1:2:4 ) Bed Block Of Size 30Cmx30cmx60cm, Complete All As Specified And Directed, Comprising The Following :- 3 ( A ) Mccb 320 Amp, 4 Pole, 415 Volt, 50Hz, Ac, With Rupturing Capacity 25 Ka With Adjustable Thermal And Fixed Magnatic Release ( O / G ) - 01 No. ( B ) Mccb 250 Amp, 4 Pole, 415 Volt, 50Hz, Ac, With Rupturing Capacity 25 Ka With Adjustable Thermal And Fixed Magnatic Release ( O / G ) - 03 No. ( C ) Mccb 100 Amp, 4 Pole, 415 Volt, 50Hz, Ac, With Rupturing Capacity 16 Ka With Adjustable Thermal And Fixed Magnatic Release ( O / G ) - 01 No. ( D ) On Load Change Over Switch I-O-Ii , 320 Amp, 4 Pole, 415 Volt, 50 Hz - 01No. ( E ) Pre-Wired Digital Meter With Voltmeter, Ammeter, Slector Switch, Cts And Led Indication Lights- 01 Set. ( F ) Bus Bar Chamber With Electrolytic Grade Aluminum Strip With Heat Shrink Cable Sleeves With Colour Code Supported On Epoxy Resin Based Insulator 4 Strips Of Suitable Length For Current Rating 400 A. 4 Taking Down Old Unserviceable Lt Panel And Supply, Fixing, Connecting And Commissioning Of Lt Panel, Factory Made ( Cpri Approved ) , Indoor / Outdoor Type ( Kiosk ) , Floor Mounted, Compartment Type, Dust And Vermin Proof ( Ip-55 Protection ) Suitable For 415 Volts Grade, 3 Phase, 4Wire 50Hz Ac Supply With 400 Amp Aluminium Bus Bar Tpn, Colour Coded & Sleeved, Fabricated Out Of 3.15 Mm Thick Mild Steel Crca Sheet Mounted On 50Mmx50mmx6mm Angle Iron Frame And Welded To 75Cm Long 50Mmx50mmx6mm Size Angle Iron Legs ( 04 Nos ) , Front & Rear Openable, With Front Hinged Double Door Inclusive Locking Arrangement With Provision Of Allincoming / Outgoing Cable Entries Alongwith Suitable Size Double Compression Type Cable Glands And Adopter Boxes For Incoming And Outgoing Cable & Spray Painting With Two Coats Of First Quality Super Enameled Grey Paint Over And Including A Coat Of Red Oxide Primer, Including Anti-Corrosive Treatment ( 7 Tank ) , Legs Grouted In Floor In Pcc ( 1:2:4 ) Bed Block Of Size 30Cmx30cmx60cm, Complete All As Specified And Directed, Comprising The Following :- 5 ( A ) Mccb 320 Amp, 4 Pole, 415 Volt, 50Hz, Ac, With Rupturing Capacity 36 Ka With Adjustable Thermal And Fixed Magnatic Release ( O / G ) - 01 No. ( B ) Mccb 250 Amp, 4 Pole, 415 Volt, 50Hz, Ac, With Rupturing Capacity 25 Ka With Adjustable Thermal And Fixed Magnatic Release ( O / G ) - 03 No. ( C ) On Load Change Over Switch I-O-Ii , 400 Amp, 4 Pole, 415 Volt, 50 Hz - 01No. ( D ) Pre-Wired Digital Meter With Voltmeter, Ammeter, Slector Switch, Cts And Led Indication Lights- 01 Set. ( E ) Bus Bar Chamber With Electrolytic Grade Aluminum Strip With Heat Shrink Cable Sleeves With Colour Code Supported On Epoxy Resin Based Insulator 4 Strips Of Suitable Length For Current Rating 400 A. 6 S&F In Replacement Of Sheet Metal Enclosure Type Change Over Switch On Load Front Handle Four Pole 415 Volts 50 Hz 400 Amps Including Mountingarrangement On Metallic Frame Work Of Appropriate Section And Size On Walls Or Panels Complete All As Specified And As Directed.Make:- Havells / L&T / C&S 7 S&F In Replacement Of Sheet Metal Enclosure Type Change Over Switch On Load Front Handle Four Pole 415 Volts 50 Hz 320 Amps Including Mountingarrangement On Metallic Frame Work Of Appropriate Section And Size On Walls Or Panels Complete All As Specified And As Directed.Make:- Havells / L&T / C&S 8 S&F In Replacement Of Sheet Metal Enclosure Type Change Over Switch On Load Front Handle Four Pole 415 Volts 50 Hz 200 Amps Including Mountingarrangement On Metallic Frame Work Of Appropriate Section And Size On Walls Or Panels Complete All As Specified And As Directed.Make:- Havells / L&T / C&S 9 S&F Cable End Joint Kit Heat Shrinkable Type Suitable For 1.1 Kv ( Lt ) Indoor / Outdoor Type , For Cable Size 150 To 240 Sqmm And Suitable For 3 1 / 2 Or 4 Core , Complete All As Specified And Directed Make: 3M / Denson Or Equivalent 10 S&F Cable End Joint Kit Heat Shrinkable Type Suitable For 1.1 Kv ( Lt ) Indoor / Outdoor Type , For Cable Size 70 To 120 Sqmm And Suitable For 3 1 / 2 Or 4 Core , Complete All As Specified And Directed Make: 3M / Denson Or Equivalent 11 Stand Made Out Of Angle Iron And Flat Iron Of Size Required As Per Site For Fixing Of Change Overs Of Capacity 250 Amp To 400 Amps In And Includingpcc Work For Fixing Of Stand , Necessary Excavation In Ground And Other Items Required Such As Nut, Washer And Bolts As Required On Site As In Relacment , Complete All As Specified And As Ditected By Engineer-In -Charge. 12 M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode 600X600x6mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level, Connected To Galavanised Iron Strip 32X6mm As Earthing Lead By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanisediron Or Steel All As Shown In Electrical Plate No 3 Connected To Outdoor Lt Panel Or Bus Bar All As Specified Including Earth Work In Any Type Of Soil, Pcc 1:3:6 Type C1 Chamber & Rcc 1:2:4 Type B1 Cover 40Mm Thick, With 8Mm Dia Steel Deformed ( Tmt Bars ) Reinforcement At 150Mm C / C Both Ways, 20Mm Dia Gi Medium Grade Pipe For Watering , Water Funnel, Complete All As Specified And Testing On Completion. 13 Material And Labour For Cable Route Indiacator Made Out With 300 X 300 X 300 Mm Thick Pcc Blockof1:3:6 Type C1 Byusing 20Mm Gradded Aggragate Andembossing Lt And Ht Indicator Made Out With Ms / Ci Round Shaped Sheet Welded With 200 Mm Long Ms Flat Ironincluding 2 Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer To Iron Surfacesfixing At Different Cable Routes Complete All As Specified And Directed By Engr -In -Charge. 14 Excavation In Trenches For Laying Under Ground Cable, Errection Of Poles And Stays Not Exceeding 1.50M Wide And Not Exceeding 1.50M In Depth And Getting Out In For Any Type Of Soil. 15 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick. 16 Removing Surplus Soil To A Distance Not Exceeding 50M And Deposited Where Directed At A Level Not Exceeding 1.50M From The Starting Point. 17 Sand Cushioning To Under Ground Cable In Trenches / Ducts In Layers Of 8 Cm Deep Before Laying The Cable And 15 Cm Deep After Laying And Stretching The Cable. 18 Supplying And Laying, Unreinforced Precast Concrete Cable Cover Lv Type-1, Flat, Of Size 250X150x40mm, Laid Flat And Dryin Trenches Over The Cable For Protection, Length Perpendicular To The Direction Of Cable Adjacent To Each Other, Complete All As Specified And Directed. 19 Taking Out Old Unserviceable Lt Ugpvc / Xlpecable Of Any Size 1100 V Laid In Trenches / On Poles Through Gi Protection Pipe Note: Excavattion And Earthwork Shall Be Measuured And Paid For Separately Under Respective Items. 20 Supply & Laying Of Ug Cable Xlpe Insulated Armouredheavy Duty Elect Cable With Stranded Aluminiumconductor 1100 Volts Grade Cross Section Area 120 Sqmm 3.5 Core Laid In Trenches / Fixing On Panels / Walls / Poles Or Passing Through Pipe Including Connecting With Suitable Lugs, Glands, Nuts And Bolts And Testing Complete All As Specified And Directed.Note: Excavattion And Earthwork Shall Be Measuured And Paid For Separately Under Respective Items . 21 All As Per Item No 9 Here-In-Beforee But Size 95 Sqmm 3.5 Core. 22 All As Per Item No 9 Here-In-Beforee But Size 35 Sqmm 3.5 Core 23 Material And Labour Cutting Existing Road / Pcc Hard Standing / Pavement For Laying Of Under Ground Cable / Gi Tubing And Making Good To Match With The Existing Surface With Pcc 1:2:4 Type C-1 Using 20Mm Graded Stone Aggregatesincluding All Excuation And Earth Work Complete All As Specified And Directed.Note:- Only Pcc Shall Be Measured And Paid Separately. 24 M&L For Laying Gi Tubing Light Grade 50 Mm Dia For Cable Potection In Road / Floor. 25 Supply And Fix In Repairhigh Power Led Street Light Fittings Energy Saving Luminaire, With System Wattage 60 Watt With System Efficacy ( Lm / W ) Not Less Than 90 Lumens Per Watt, Total System Lumen Not Less Than 5400 Lumens, Pf Not Less Than 0.95, High Pressure Die Cast Aluminium Alloy Lm6 Housing Heat Sink For Better Heat Transmission With Epoxy Powder Coated Ip-65 Class 1 Protection, Toughened Glass / Uv Stabilized Polycarbonate Cover, Well Designed Thermal Management System Complete All As Specified And As Directed. Make: Wipro / Philips / Ge / Crompton 26 Note : Schedule Of Creditto Be Deducted On Acceptances Of Bid.Details Of Schedule Of Credit Is Given In Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 79580.0 /-
Tender Value
INR 39.79 Lakhs /-