}

Tender For Provision Of Work Services For Ku Band And Satcom Equipment At Hq Cac At Af Stn Bamrauli, bamrauli-Uttar Pradesh

Military Engineer Services-MES has published Tender For Provision Of Work Services For Ku Band And Satcom Equipment At Hq Cac At Af Stn Bamrauli. Submission Date for this Tender is 23-04-2024. Radio Antennas Tenders in bamrauli Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42989649
Corrigendum : Tender For Provision Of Work Services For Ku Band And Satcom Equipment At Hq Cac At Af Stn Bamrauli
Open Tender
Indian
Uttar Pradesh
bamrauli
23-04-2024

Tender Details

Tender For Provision Of Work Services For Ku Band And Satcom Equipment At Hq Cac At Af Stn Bamrauli- 1 Surface Dressing Not Exceeding 15 Cm Deep And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed. 2 Excavation In Trenches , Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M In Depthfor Founddationetc And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed. 3 M&L Cement Concrete 1:4:8 Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concerete Complete All As Specified And As Directed. 4 M&Lreinforced Cement Concrete Nominal Mix 1:2:4 Typeb-1 Using 20 Mm Graded Stone Aggregateas In Foundation , Rafts Footings , Plinth Beamand Similar Other Work Complete All As Specified And As Directed. 5 Use And Waste Of Form Work To Sides Of Concrete Foundations, Footing Bases Of Columns Rafts And Raftsbeam, Rough Finished Surfaces Flat Complete All As Specified And As Directed. 6 M&L Mild Steel Tmt Bar 10Mm Dia And Over Cut To Length Bent To Shape Required Including Cranking Bending Spirally For Hooping For Column Hooking End And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clip Complete All As Specified And As Directed. 7 M&L Mild Steel Tmt Bar 5Mm Dia And Over Upto And Including 10 Mm Dia As In Stirrups, Cut To Length Bent To Shape Required Including Cranking Bending Spirally For Hooping For Column Hooking End And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clip Complete All As Specified And As Directed. 8 M&Lreinforced Cement Concrete Nominal Mix 1:2:4 Type B-1Using 20 Mm Graded Stone Aggregate As In Columns, Pillars, Piers, Post And Struts Etc Complete All As Specified And As Directed. 9 Use And Waste Of Form Works To Sides Of Pillar, Strut, Piers, Columns And Stanchions Similar Surface To Concrete Flat , Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed. 10 Returning, Filling In, Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cmas In Soft / Loose Soil Complete All As Specified And As Directed. 11 Removing Excavated Soilto A Distance Exceeding 250 M But Not Exceeding 500 M Anddepositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point Complete All As Specified And As Directed 12 M&L Treating The Backfill In Contact With Foundation At The Rate Of 7.5 Litre Of Emulsion Per Square Meter Of Vertical Surface ( Area Of The Sub Structure In Contact With Backfill To Be Measured ) Complete All As Specified And As Directed. 13 M&L Treating The Top Surface Of Filled Earth @ 5 Litres Of Emulsion Per Sqm For Floor Complete All As Specified And As Directed. 14 M&L Treating The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Meter Of Surface Area Complete All As Specified And As Directed. 15 M&L Treating The Soil Along With External Perimeter Of Building At The Rate Of 2.25 Litre Of Emulsion Per Meter Of The Perimeter Wall Complete All As Specified And As Directed. 16 M&L Cement Concrete 1:5:10 Type E-2 Using 40 Mm Graded Stone Aggregate As Infoundation And Mass Concrete Complete All As Specified And As Directed. 17 M&L For Brickwork With Sub Class B Bricks, Straightor Curved On Plan Exceeding 6M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed. 18 M&Lreinforced Cement Concrete Nominal Mix 1:2:4 Type B-1 Using 20 Mm Graded Stone Aggregate As In Beams, Cantilever, Bressummers, Lintels Over 1.50 M Span And Similar Work Complete All As Specified And Directed 19 M&L Reinforced Cement Concrete Nominal Mix 1:2:4 Type B-1 Using 20Mm Graded Aggregate In Roof Slabs Supportedwalls, Beam And Columns In Floors, Roofs, Landing, Shelves Etc Complete All As Specified And As Directed. 20 Use And Waste Offormwork To Sides And Soffits Of Floors Or Roof Beam, Beam Haunching, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Also Splays Between Floors And Beams Etc, Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed. 21 Use And Waste Of Formworks To Soffits Of Suspanded Slab Such As Roof Slabs, Floor Slabs, Landing And Similar Works Not Exceeding 200 Mm Thick Horizontal Or Sloping , Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed. 22 M&L Water Proofing Treatment To Roof As Per Per ManufacturerS Instructionswith The Following Specification:-. ( A ) 15 Mm Thick Plastering In Cement Mortar 1:4 Mixed With And Including Water Proofing Compound @3% By Weight Of Cement Including Preperation Ofroof Surfaces. ( B ) Applying Evenly A Coat Of Bitumineous Primer @ 0.5 Litre Per Sqm ( C ) Applyingevenly A Coat Of Hot Blow Bitumen 85 / 25 Grade @ 1.2 Kg Per Sqm ( D ) Applying App Based Polymeric Membrane Minimum 3 Mm Thick And Minimum Weighing 3Kg / Sqmlaid On Primed Surface By Lpg Forced Torch Application With A Side & End Overlaps Of Minimum 100 Mm. ( E ) Applyingevenly A Coat Of Hot Blown Bitumen 85 / 25 Grade @ 1.2 Kg Per Sqm Over Water Proofing Membrane ( F ) Applying A Coat Of Bituminous Basedaluminium Primer @ 100 Gm / Sqm On Top Including Sealing All Joints By Thermo Fusion Complete All As Per ManufacturerS Instructions ( G ) Testing For Water Tightness By Water Ponding At Least 72 Hours 23 M&L25 Mm Thick Cement Concrete1:2:4 Type B-0Using 12.5 Mm Graded Stone Aggregate As In Levelling Course, Surface Finished Even And Fair Complete All As Specified And As Directed. 24 M&L18-20 Mm Thickmirror Polished Machine Cut Kota Stone Slab Flooringover And Including15mm Thick Cement Screed Bed In Cement Mortar 1:4 , Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified And As Directed. 25 M&L 18-20 Mm Thick Mirror Polishedmachine Cutkota Stone Slabas In Risers Of Steps, Skirting, Dado And Pillar Laid Overand Including 10 Mm Thickrendering In Cement Mortar 1:4 Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified And As Directed. 26 M&L15 Mm Thick Renderingin Cement Mortar1:6 Onbrick Work Or Concretesurfaces Of Walls, Surface Finished Even And Fair Complete All As Specified And Directed. 27 M&L15 Mm Thick Renderingin Cement Mortar1:4 Onbrick Work Or Concretesurfaces Of Walls, Surface Finished Even And Fair Complete All As Specified And Directed. 28 M&L5 Mm Thick Rendering In Cement Mortar1:3 On Ceiling , Surfacefinished Even And Fair Complete All As Specified And Directed 29 M&L Applying Three Coats Of White Wash On Ceiling Including Preparation Of Newly Plastered Surface Of Ceilingcomplete All As Specified And As Directed 30 M&L Applying Two Coats Of Oil Bound Distemper Over A Coat Ofalkali Resistant Primerover And Including 1Mm Thick Birla White Wall Care Putty Including Preperation Of Plastered Surfaces Complete All As Specified And As Directed. 31 M&Lapplyingtwo Coats Of Cement Base Paint Overone Coat Cement Wash With White Cement Including Preperation Of Plastered Surface Of Wall Complete All As Specified And As Directed. 32 M&L Powder Coated Anodised Aluminium Doors ( Thickness Of Powder Coating Not Less Than 50 Micron ) Sliding Or Hanging Type With Frame Size 101.60Mmx44.45Mmx 2.00 Mm Thick And Shutter Aluminium Anodised With Top Rail 47.62Mmx 44.45Mm X 1.50Mm And Style 47.5Mm X 44.5 Mmx1.5 Mm , Lock Rail 83.50Mmx 44.45Mm X 1.50Mm And Bottom Rail150.00 Mmx 44.50Mm X 2.50Mmincluding Necessary Aluminium Fittings Like Aluminium Butt Hinges 04 Nos , Aluminium Handles 150Mm 02 Nos, Aluminium Tower Bolts 200Mm 01No, Mortice Lock 4 Lever Ms, Hydraulic Door Closer Of Suitable Capacity 01 No, Aluminium Door Stopper 01 Nos, Jointing Cleats, Glazing Cleats, Rubber Packing , Anodised Aluminium Snap Beading, Screws Etc With Panelling In Two Parts With12mm Thick Prelaminated Partical Board With Both Side Decorative Lamination Of Approved Texture In Lower Panel And 5Mm Thick Tinted Glass In Upper Panels Including Requiredall Fittings And Fixtures Complete All As Spesified And Directed. 33 S&F Premium Sand Textured Finished Mineral Fibre Acoustical Ceiling Tiles Of Size 600Mmx600mmx16mm Thick And Placed On Galvanised Iron Grid Module Consisting Of Wall Angle Section 24Mmx24mm And Tee Section With Web Height Of 38Mm And Flange 24Mm And Cross Tee 24Mmx24mm Size With Suspension System Complete All As Per Td Drg No-Cwe / Bam / Td-34 Dated 29 Sep 2016Note :- Ceiling Tile Shall Be Of Armstrong Brand Dune Rh99 ( Bevelled / Tegular ) Or Equivalent Make As Approved. 34 Surface Excavation Not Exceeding 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soilcomplete All As Specified And As Directed. 35 Excavating In Post Holes ( Or Similar Holes ) Each Not Exc 0.5 Cum , Gettng Out In Hard / Dense Soil And Removing The Soil To A Distance Not Exceeding 50 M Complete All As Specified And As Directed. 36 M&L Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensil Strength Of 550 Mpa As In Roof Covering / Cladding To Wall Fixed With Self Tapping Screws Complete All As Specified And As Directed. 37 M&Lstructrual Steel Work As In Frame Work Ofangle Iron As In Vertical Post Fixed With Cleat And Connecting Plate Etc Including Necessary Welding, Drilling Etcconforming To Fe-410 W Grade E-250 Quality Complete All As Specified And As Directed. 38 M&L Structural Steel Work As In Rolled Mild Steelangle Iron Framed Work For Rooftrussesas In Main And Cross Beams Hip And Jack Rafter, Purlin Includingdistance Pieces , Cleats Or Other Connecting Plates Including Necessary Welding, Drillingas Required Complete All As Specified And As Directed. 39 M&L Broken Stone Hardcore Of Gauge Not Exceeding 63Mm, Deposited , Spread And Levelled In Layers Not Exceeding 15Cm Thick Watered And Rammed To A True Surface Complete All As Specified And As Directed. 40 M&L Cement Concrete 1:2:4 Type B-2 Using 40Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete To Post Holesor Other Similar Works Complete All As Specified And As Directed. 41 M&L Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer Including Preparation Of Steel And Iron Surfaces Over 10Cm In Width Or Girth, Not Otherwise Described Complete All As Specified And As Directed. 42 M&L Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate As In Coping, Benching, Bed Block, Cills, Filling Holes In Wall Like Including Weathering And Slightly Rounded Or Chamfered Angle And Throating As Required Includingnecessary Use And Waste Form Work. Complete All Specified And Directed. 43 M&L Applying Three Coats Of White Wash On Wall Including Preparation Of Newly Plastered Surface Of Wallcomplete All As Specified And As Directed. 44 Excavating In Post Holes ( Or Similar Holes ) Each Not Exc 0.5 Cum , Gettng Out In Soft / Loose Soil And Removing The Soil To A Distance Not Exceeding 50 M Complete All As Specified And As Directed. 45 M&L Cement Concrete1:3:6, Type C-2 Using 40 Mm Graded Stone Aggregate In Foundation And Mass Concrete Complete All As Specified And As Directed. 46 M&L Mild Steel Work As In Posts And Struts In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wireetc, Flat Iron Fillets For Securing Wire Mesh Etc Including All Necessary Drilling, Bolting Or Riveting, Etc Andother Similar Work Conforming To Fe-290 Gde E-165 Complete All As Specified And As Directed. 47 M&L Mild Steel Work As In Tie Bars With Screwed Ends, Nuts, Washers And Mild Steel Plates For Walls, Chimneys, Roofs, Arches, Etc. King Rods And Straining Bolts Confomiing Tofe-290 Gde-E-165 Complete All As Specified And As Directed. 48 M&L Mild Steel Work As In Hand Rails, Half Round Or Other Steel Section Or Core For Wooden Hand-Rail Straight Portion, Drilled And Countersunk For Balusters Running Bars, For Doors, Balusters, Nosing To Steps Including Embeding In Concrete And Screwing Etc And Similar Work Conforming To Fe-290 Gde E-165 Complete All As Specified And As Directed. 49 S&F Mild Steel Screw Bolts ( Machine Made ) 5 To 10 Mm Diameter Of Neck With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Not Exceeding 5Cm Long Complete All As Specified And As Directed. 50 Supply Only 4 Mm Dia Galvanised Steel Wire 50 Mm X 50 Mm Mesh, Chain Link Mild Steelfencing Complete All As Specified And As Directed. 51 Fixing Only Chain Link Fencing Including Line Wires, Any Mesh, Size And Type To Any Type Of Standard, Rails, Straining Bolts Etc Including Provn Of Binding Wire Complete All As Specified And As Directed. 52 M&L Applying Two Coats Of Black Japan Paint Over One Coat Of Red Oxide Primer Including Preperation Ofsteel And Iron Surfaces Over 10Cm In Width Or Girth Not Otherwise Described Complete All As Specified And As Directed. 53 M&Lreinforced Cement Concrete Design Mixm-25 Using 20 Mm Graded Stone Aggregate As In Foundation , Rafts Footing, Plinth Beam, Bases Of Column And Other Similar Work Complete All As Specified And As Directed. 54 M&Lreinforced Cement Concrete Design Mixm-25 Using 20 Mm Graded Stone Aggregate As Incolumns, Pillars, Piers, Post And Struts Etc Complete All As Specified And Directed 55 M&L Mild Steel Work As In Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc Complete, Drilled For Fixing Of Steel Sheeting Or Othercovering. Doors To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings ( Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides ) Andhanging; Also Fastening And Fixing Complete All As Specified And As Directed. 56 M&L Granite ( Of Any Type ) Tiles 20Mm Thick Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Cutting And Polishing Types Over Andincluding 15Mmthick Screed Bed Or Beddinglayer In Cement Mortar 1:6Complete All As Specified And As Directed. 57 M&L Point Wiring With Single Corefrlsh Pvc Sheathedmulti Stranded Copper Conductor Of Size 1.5 Sqmm Drawn Through And Including Non Metallic Rigid Pvc Conduit Medium Grade Isi Markednot Less Than 20Mm Dia With Gi Saddles Gi Screws, Rawl Plugs ( Concealed Conduit Wiring In Walls And Casing Capping On Ceiling Or Roof ) Including Tee, Junction Boxes And Provision Of3 Mm Thick Plastic Laminated Sheet Cover Of Suitable Size , Mild Steel Terminal Boxe With Brass Screwsfor Mounting Switchs, Sockets, Regulators Etc Including 1.5 Sqmm Frlsh Pvc Sheathedstrandedcopper Conductor Cable As Continuous Earth Wire And Connected To Main Earth Dolly Complete All As Specified And Directedfor One Light / Fan / Exhaust Fan Point / Bell Point Controlled By One Switch. 58 Description Same As Peritem No 57 Above But For One 3 Pin 5 Amps Socket Out Let Point On The Same Board With Other Switch Complete All As Specified And Directed . 59 Description Same As Peritem No 57Above But For 3 Pin 5 Amps Socket Out Let On Independent Boardcomplete All As Specified And As Directed . 60 Description Same As Peritem No 57 Above But For One Power Point 3 / 5 Pin 15 Amps Socket Out Letindependent Board Using 4.0 Sqmm Multi Stranded Frlsh Pvc Insulated Copper Conductor Cablewith 4.0 Sqmm Multi Stranded Frlsh Pvc Insulated Copper Conductor Cable As Earth Wire Complete, All As Specified And Directed. 61 S&F5 Amp Switch Piano, Flush Type , Single Pole One Way Complete, All As Specified And Directed . 62 S&F Socket Out Let2 In 1, 3 Pin, 5 Ampflush Type Complete, All As Specified And Directed . 63 S&F15 Amp Switch Piano, Flush Type, Single Pole One Way Complete, All As Specified And Directed . 64 S&Fsocket Outlet 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified And As Directed . 65 S&F Ceiling Rose, 3 Phasepvc Or Polycarbonate, Isolated Body Complete All As Specified And As Directed . 66 S&F Factory Made Epoxy Powder Coated Vertical Load Line Distribution Boards ( Vtpn ) 4 Ways 415 Volt Gradewith Double Doorwith Acrylic Top Cover ( Ip-43 Protection ) Fabricated From Minimum 1.6 Mm Thick Crca Sheet And Fixed Flush To Wall Suitable For Universal Mounting And Including 250 Amp Copper Bus Bar Netrual Barstandard Din Rail, Earth Bar And Cable Ties For Cable Manangement With Top And Bottom Removable Gland Plates And Knockouts Complete All As Specified And Directed.Make:- Legrand / L&T / Abb As Approved. Note:- Mcb / Mccbs Shall Be Measured And Paid Seperatly Under Respective Item. 67 S&F Mccb4 Pole, 415 V, 40 Ampwith Breaking Capacity 25 Ka Including Connection And Testing Complete All As Specified And Directed , 68 S&F Mcb Single Pole, 6-32A , 10Ka B Series Complete All As Specified And As Directed. 69 S&F Submain Wiring With Four Single Core 6.0 Sqmmfrlsh Pvc Insulatedmultistrand Copper Conductor Cable Drawn In Andincludingconcealed Rigid Non Metallic Pvc Conduit Dia Not Less Than 20 Mm , Medium Gradeisi Marked With All Fittings And Fixing Accessories And One Single Core 6.0 Sqmmfrlsh Pvc Insulated Multistrand Copper Conductor Cable As Continuous Earth Wire Complete All As Specified And As Directed.Note:- Four Run Of 6.0 Sq Mm Copper Cable, One Run Of Pvc Conduitand One Run Of 6.0 Sq Mm Copper Cable Earth Wire Shall Be Measured As One Unit. 70 M&L Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mmx600mmx6mm Thick, Buried Directlyin Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level, Connected To Galvanised Earth Lead Wire 4.0 Mm Dia ( Upto 7.5 M In Length From Earth Plate ) By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanisediron Or Steel , Filling Adequate Quantity Of Charcoldust And Common Salt All As Shown In Electrical Plate No 3 Of Ssr Part-2009, Connected To Earthing With Dbs All As Specified Including Excavation And Earth Work In Any Type Of Soil, Pcc 1:3:6 Type C-1 Using 20Mm Graded Stone Aggregate In Chamber &40Mm Thick Rcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate As In Cover Slab, Reinforced, With 8Mm Dia Tmt Bar At 150Mm C / C Both Ways, 15Mm Dia Gi Pipe Light Grade For Earth Lead Protection, 20Mm Dia Gi Medium Grade Pipe For Watering , Water Funnel Etc Complete All As Specified And Testing On Completion. 71 S&F Led Street Lightfitting 35 Watt, 230 V, 6000K New Generation Energy Saving And Environmental Friendly Long Life Made Up Of Pressure Die Cast Aluminium Housing With High Efficient Led As Lighting Source And Pc Cover Having Top Opening Seperate Driver Compartment With Ip-66 Protection And Impact Resistance Of Ik07 Roadway Luminaries With Electronic Driver Including Necessary Connection With Three Core Copper Cable Of Suitable Size Of Required Lengthincludingmounting Bracket Made Out Of40mm Dia Gi Pipe Light Grade Having Length Not Less Than 1 M With Suitable Size Of Mild Steel Clamp, Nuts, Bolts And Washers Etc Complete All As Specified And As Directed.Make:- Crompton / Philips / Bajaj / Havells As Approved. 72 S&F2zone Conventionalfire Alarm Control Panel Complying With Bs En 54 Single Loop Panel Of Capacity 6 Detector Complete All As Specified And As Directed. 73 S&Fdetectors Complying Withmultisensor Detector With Heat And Smoke Combination Above False Ceiling Complete All As Specified And As Directed. 74 S&Fdetectors Complying Withmultisensor Detector With Heat And Smoke Combination Below False Ceiling Complete All As Specified And As Directed. 75 S&F Addressable Intelligent Fault Isolator Module Complete All As Specified And As Directed. 76 S&Fmanual Call Point Break Glass Type With Alarm Led Complete All As Specified And As Directed. 77 S&F Fire Alarm Sounders / Sirens Electronic Type Horizontal Single Stage Continuous Normal Operation For At Least 50 Minutes With Sound Level 65 Db To 120 Db Measured At 1.5 Meter With Sound Output Variation Of + 5 Db For 1000 Meter Range Complete All As Specified And As Directed. 78 S&F Submain Wiring With Two Run Of1.5 Sqmm Frlsh Pvc Insulatedstranded Copper Conductor With One Run Of 1.5 Sqmm Frlsh Pvc Insulated, Stranded Copperconductor In And Including Mild Steel Conduit Dia Not Less Than 20 Mm Complete All As Specified And As Directed. 79 Supply, Installation, Commissioningand Testing Inverter Split Type Air Conditioner Of Capacity 2.0 Tr, 5 Star Rated Invertorwith Cordless Remote Control Unit And In Built Air Ioniser, Plasma Filter For Better Indoor Air Quality, Star Rated Suitable For Wall Mounted, Single Phase, 230 / 250 Volt Ac Including Cuttinghole Inexisting Wall For Fixing Indoor And Outdoor Unit And Making Good To Disturbed Surfaces With Cement Mortar 1:2 After Commissioning, Making Necessary Connections, Unplasticised20 Mm Dia Pvc Pipe Medium Grade For Draining Out Condensed Waterof Required Length As Per Site Requirementincluding Necessary Connection With 2.5 Sqmm Multistranded Copper Cable Of Suitable Length, Copper Tube With Insulation, Fixing Bracket And Other Accessories As Required At Sitecomplete All As Specified And Directed.Make:-Carrier / Daikin / Voltas / Blue Star As Approved.Note :- Installation And Commissioningis To Be Carried Outthrough Oem Orauthorised Service Centre / Dealer. 80 S&F 5 Kvavoltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type And Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5%Complete All As Specified And As Directed. 81 M&L For Sub Main Wiring With Two Single Core 4 Sqmmstranded Copper Conductor Cable Frlsh Pvc Insulated And Unsheathed Drawn In Includingconcealedpvcconduitdia Not Less Than 25 Mm With Necessary Fittings Such As Bend, Tee , Junction Etc Including4 Sqmm Frlsh Pvc Insulated Unsheathed Copper Conductor Cable As Earth Wire Complete All As Specified And As Directed.Note:- Two Run Of4 Sq Mmcopper Cable, One Run Of Pvc Conduit And One Run Of Copper Cable As Earth Wire Shall Be Measured As One Unit. 82 S& Fsinglepole And Neutral Enclouser With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb, 20 Amps 230 Vcomplete All As Specified And As Directed . 83 S&F Ac Controller For Controlling Four Ac At A Time Consisting Lcd Display, Metal Body With Wall Mountings, Temprature Sensor, Alarm System For Any Error, Auto And Manual Facility For All Ac Complete All As Specified And As Directed. 84 Supply, Laying , Jointing & Testing 95 Sqmm Cross Sectional Area , 3 Corexlpe Insulated , Screened, Pvc Bedded, Galvnised Steel Stripor Wire Armoured, Electric Powercable ( Heavy Duty ) With Aluminum Conductor, 11000 Volts Earthedconforing To Is-7098 Laidin Trenches Or Through Pipes Or In Ducts Or On Poles Complete All As Specified And As Directed. 85 Supply, Insatllation , Testing And Commissioning Of Step Down Transformer Of Capacity 100 Kva Outdoor Type Complete With Standardfitting Accessories, Ht 11 Kv, 3 Phase 4 Wire, Lt 433 Volt, 3 Phase 4 Wire With Off Load Changer On Primary Side To Carry Secondary Voltage + 7.5% With Tappings At Every 2.5 % All As Per Latest Is 1180-2014 Level 2, Copper Wound Oil Cooling With Fins Vector Group: Dyn 11, Including Initial Oil Filling Complete All As Specified And As Directedincluding The Following Accessories:- ( A ) One Cable Box Ht Side Consisting Of 03 Nos Porcelain With Brass Bushing Rod Complete With Nuts And Wahsers Suitable For Run Of 03 Core Ht Ug Cable ( B ) One Cable Box Lt Side Consisting Of 4 Nos Porcelain With Brass Bushing Rods Complete With Nuts And Washers Suitable For Runs Of 3.5 Core Lt Under Ground Cables ( C ) Oil Conservator With Filter Type Drain Valve And Oil Level Gauge ( D ) Dehydrating Breatherwith First Fill Of Dehydrating Agent ( E ) Explosion Vents ( F ) Thremometer Pocket On Tank Cover ( G ) One Number 100 Mm Dia, Dial Type Thermometer Vapour Pressure Type Having Range 0 To 120 Degree Centrigrade ( H ) Rating Plate And Terminal Marking Plate ( J ) Earthing Arrangement ( K ) Oil Drain Filter Valve ( L ) Oil Drain Valve ( M ) Lifting Hook ( N ) Oil Conservator With Filling Hole Cap ( O ) Air Release Valve Plug ( P ) Four Plate Solidcast Steeldetachable Rollers 86 M&Learthing Complete With Galvanised Steel Earth Plate Electrode 600X600x6mm Thick, Buried Directly And Preferably Vertically In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Galavanised Earth Strip 32Mmx6mm As Earthing Lead By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanisediron Or Steel All As Shown In Electrical Plate No 3 Of Ssr Part-I - 2009, Connected To Earthing Point Of Outdoor Panel Boards All As Specified Includingexcavation And Earth Work Any Type Of Soil, Pcc 1:3:6 Type C-1 Using 20Mm Graded Stone Aggregate For Chamber And 40Mm Thick Rcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate, Reinforced With 8Mm Dia Deformed ( Tmt Bars ) At 150Mm C / C Both Ways, 50Mm Dia Gi Pipe Light Grade For Ptotection, 20Mm Dia Gi Medium Grade Pipe For Watering , Funnel Etc Complete All As Specified And Testing On Completion. 87 S&F Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Outdoor Termination, Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitablefor Cross Sectional Area 95 Sqmm, 3 Corexlpe Armoured Aluminium Conductor Cable Completeall As Specified And Directed. 88 Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor , 1100 Volt Grade, Cross Sectional Area 50 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 89 Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor , 1100 Volt Grade, Cross Sectional Area 25 Sqmm 4 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 90 Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor , 1100 Volt Grade, Cross Sectional Area 10 Sqmm 4 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 91 Removing Excavated Soilto A Distancenot Exceeding 50 Manddepositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point Complete All As Specified And As Directed. 92 M&L For Natural River Sand As Cushioning Of Cables Including Spreading And Punning Downcomplete All As Specified And As Directed.Note : Punned Thickness Shall Be Measured For Payment Purpose 93 Supply And Laying Old Size Bricks Of Designation 75 For Cable Protection Complete All As Specified And As Directed. 94 Supply And Laying Un-Reinforced Precast Concrete Cable Cover Class Hv Type 1, Flat Of Size300 Mm X 180 Mm X 40 Mm Complete All As Specified And As Directed. 95 S&F Cable Path Indicator Made Of Cast Iron Plate 150 Mm Dia , 6 Mm Thick Rebated To Spot Welding With Galvanised Ironhaving 15 Mm Dia, 450 Mm Long Complete All As Specified And As Directed. 96 S&Fsheet Metal Chambersingle Door Made Of 3.15 Mm Thick Sheet Factory Madeofsize 30Cmx30cmx15 Cm To Be Inside The Existing Wall With , 4 Nos Copper Bus Bar 200 Amps Mounted On Insulator With Incommingmccb 100 Amp, 25 Kaincluding All Incomming And Out Going Connections With Lugs Of Required Size Including Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Primer On Exposed Surfaces Of Steel And Pcc 1:2:4 Type B-1 Uding 20 Mm Graded Stone Aggregate As In Fixing Etc Including Testing Complete All As Specified And As Directed. 97 Supply, Installation, Commissioning And Testing 62.5 Kva Diesel Engine Driven Generating Set, Static, Silient ( Sound Proof Enclosure ) , Water Cooled, 415 Volts , Ac, 3 Phase, 4 Wire System Of Supply, 50 Hz At Power Factor 0.8 Minimum.The Dg Set Shall Consists Of Diesel Engine Coupled To A Matching Alternator, Through Flexible Coupling And Mounted On Common Base Frame And Complete With Control Panel Standardized By Manufacturer, Fuel Tank With Mounting Arrangements And Inlet, Outlet Return Inlet Oil Arrangements, Exhaust Pipe Complete And Suitable For Conditions Prevalent At Bamrauli ( Capacity Of Engine, Alternators Shall Worked Out Taking All Derating Factors Into Consideration ) Including Pcc Foundation ( Of Suitable Size Leaving At Least 0.5M All Around For Ease Of Movement And 0.5M Height ) , Anti-Vibration Pads Complete All As Specified And Directed, Including All Feature To Comply With Latest Cpcb-Iv Guidelines And Comprising Of Followings Accessories:- 98 ( A ) Diesel Engine:- Diesel Engine 1500 Rpm, Direct Injection, 6 Cylinder, Four Stroke, Conforming To Conforming To Is:100001 / Iso3046 / Bs:649 / Bs:5514 Amended Upto Date, For Continous Running Capable Of Taking 10% Overload For One Hour In 12 Hour, Water Cooled, Naturally Turbo Charged, Capable Of Giving Adequate Bhp To Drive Alternator Capable Of Delivery 62.5 Kva At Outdoor Atmospheric Conditions Ataf Station Bamrauli , Taking All Derating Factor Into Consideration.The Engine Generally Confirm To Bs-5514, Is : 10002 : 1981 Andincluding Recd Device As Per Latest Cpcb Norms For Noise And Emission Limits And Necessary Certificate From Nal To The Effect Shall Be Submitted And Complete Ofrequiredfitting With The Following Accessories Subject To The Design Of Manufacturer :- 99 ( I ) Dynamically Balanced Fly Wheel. ( Ii ) Air Cleaner Oil Bath Type ( Iii ) Electronic Governor Class 1 A With Back Up Mechanical Governor Class 1A, Flywheel With Starter Ring ( Iv ) Dry Exhaust Manifold With Suitable Exhaust Residential Grade Silencer To Reduce The Noise Level Including Recd Device As Per Cpcb-Iv Guideline ( V ) Radiator Cooling ( Vi ) Radiator Fan With Guard ( Vii ) Vaccum Indicator ( Viii ) Fuel Filter And Fuel Houses ( Ix ) Fuel Injection Pump ( Fip ) ( X ) Fan And Water Pump Assesembly ( Xi ) Lub Oil Filter And Pump 100 ( Xii ) Electric Starting System With Battery Charging Alternator And Axial Type Started Motor Including Adequate Number Of High Capacity Maint Free Lead Acid Bty As Per Manufacturer Recommendation Including Inter Connecting Cables / Leads With Terminals Complete With Starting / Stopping Switch Voltmeter, Etc01 Set ( Xiii ) Engine Safety Shut Down System Against Lowoil Pressure And High Water Pressure ( Xiv ) Exhaust Gas Driven Turbo Charge ( Xv ) Oil Filter ( Xvi ) Lub Oil Cooler ( Xvii ) Engine Main Manual With Spare Part List ( Xviii ) Suitable Designed Acoustic Enclosure As Per Cpcb Regulations ( Xix ) Any Other Item Not Included / Specified But Is A Standard Design Of The Manufacturer. 101 ( B ) Engine Instrument Panel :- Engine Instrument Panel Shall Comprising Of Thefollowing:- ( I ) Starting On / Off Switch. ( Ii ) Water Temp Auge. ( Iii ) Hour Meter Cum Rpm Indicator ( Iv ) Lub Oil Pressure Gauge ( V ) Lub Oil Temperature Gauge ( Vi ) Battery Charging Meter ( Vii ) Safety Alarm Against High Water Temp And Lub Oil Pressure. ( Viii ) Any Other Item Not Included / Specified But Is A Standard Design Of The Manufacturer. 102 ( C ) Alternator:- Alternator Shall Be Self Excited, Self Regulated, Brush Less For 62.5 Kva Continous Operation At The Speed Of 1500Rpm At 415 Volts, 50Hz Three Phase, 4 Wire System With Advance Electronic Voltage Regulator To Ensure High Voltage Accuracy With +1% With Class H Insulation And Spdp Enclosure Directly Coupled With Engine Through Flexible Couping And Conforming To Is-4722 Complete-01 No.Note:- Alternator Shall Be Able To Deliver Output Rating At Actual Site Condition. ( D ) Mounting Arrangement:-Common Fabricated Base Frame For Engine And Alternator Made From Structural Channel, Jerk Proof Pcc 1:2:4 Mix Type B1 Foundation Including Adequate Number Of Suitable Anti-Vibration Pads All As Per Manufacture Recommendations Is Deemed To Be Included In The Unit Rate Quoted By The Contractorbottom Mounted ( Or As Per Manufactures Design ) Steel Fuel Tank Fabricated Out Of 14 Swg Ms Sheet Of Capactiy Not Less Than 12 Hrs Continous Operation Inside Canopy Withfuel Level Guage, Drain Plug Locking Arrangements Etc With And Including Gi Pipe Connections Duly Laid As Per Engineering Practice Complete All As Specifided And Directed. 103 Bypass Arrangement By Providing Separate Panel Made Out Of 3Mm Thick Crca Sheet, Outdoor Type With Connecting Copper Bus Bar Of Suitable Size From Change Over And Set Of 3 Nos Indication Lamp For R, Y And B And 2 Nos 4 Pole On Load Change Over Switch Front Handle Operated Of Capacity 160 Amp Is To Be Installed Near Amf Panel Complete All As Specified And Directed. ( I ) Hour Run Meter. ( Ii ) Any Other Item Not Included / Specified But Is A Standard Design To The Manufacturer. ( E ) Amf Control Panel:- Supply, Fabricating And Testing Of Factory Mounted Cubical Automatic Main Failure Panel With Degree Of Protection Ip-42 Conforming To Is-2147, Suitable For 62.5 Kva Capacity Dg Set, Fabricated Using 14 Gauge Crca Sheet, Powder Coated Comprising Of Suitable Rated Bus Bar, Internal Wiring With Control Fuse, Provn Of Connecting Incoming And Outgoing Leads / Bus Bar As Approved With And Including Following Accessories:- ( I ) Master Switch For Auto / Manual / Reset / Off-01 No. ( Ii ) Ammeter Digital Type, 96X96 Mm With CtS-03 Nos Aux Supply 230 Vlts, Ac, Acuracyclass 1. ( Iii ) Voltmeter Digital Type 96X96 Mm To Read 0-500 Voltssupply 230 Volts, Accuracy Class 1.0. ( Iv ) Digital Frequency Meter-01 No Aux Supply 230 Volts, Ac 104 ( V ) Push Button Start, Stop, Reset-01 No. ( Vi ) Set Of Lamp For Indicating Load A Set, Low Pressure, High Cylinder Temperature, Load On Mains, Set Fails At Start, Low Oil Presure. ( Vi ) Battery Charger Connected To Load. ( Vii ) Transformer Of Adequate Rating. ( Viii ) Ractifiers ( Ix ) Dc Ampere Meter And Voltmeter. ( X ) Fault Accept / Reset Push Button. ( Xi ) Set Of Relays And Contactor Suitable For 62.5 Kva Dg Set For Automatic Start And Automatically Shut Down Of Suitable Rating And Capacity Adjustable To 70 To 100% And 2 Nos Mccb 4 Pole, 160 Amp, 25 Ka Fixed On Main Supply And Dg Set Supply. ( Xii ) Make Of Amf Control Panel Shall Be As Per Oem Recommendations. 105 ( F ) Notes : ( I ) Pcc Foundation For Dg Set And Panel Boards Shall Deemed To Be Included In Unit Rate Quoted. Pcc Foundation Of Adequate / Required Size Extending To 1.0 Mtr All Round More Than The Size Of Dg Set, As Per Manufacturer Design. ( Ii ) Dg Set Shall Be Tested As Type Test, Routine Test As Per Is In The Presence Of Ge And Rep As Decided By The Accepting Officer. ( Iii ) The Contractor Shall Submit Qap ( Quality Assurance Programme ) With In The 15 Days From Placement Of Order For Dg Set Testing At Factory Premises. Dg Set Shall Be Dispatched After Inspection Clearance By Inspecting Officer. ( Iv ) The Contractor Shall Get The Approval Of Ge For The Make Of The Dg Set As They Plan To Procure. ( V ) Prior To Manufacturing The General Arrangement Drawing Design Details Of The Dg Setshall Be Got Approved By Ge. 106 ( G ) Testing Of Dg Set ( I ) The Dg Set Will Be Tested At Manufacturer Premises / Factory In Presence Of Authorized Representative Of Accepting Officer. ( Ii ) The Dg Set Will Be Tested On Load Of Unity Power Factor ( Pf=1 ) For The Rated Kw Rating Of The Dg Set. During Testing The Dg Set Will Be Run For A Period Of 12 Hrs Non-Stop At Full Rated Capacity On Full Load And One Hr On 10% Extra Load Above The Rated Capacity After 12 Hrs Of Continuous Run. ( Iii ) The Contractor Has To Arrange External Load For The Testing Of Dg Sets At His Own Cost. The Cost Deemed To Be Included In The Quoted Amount. ( Iv ) The Contractor Has To Arrange Pol / Diesel / Staff / Technician At His Own Cost For The Testing.The Cost Deemed To Be Included In The Quoted Amount. 107 Supply, Installation, Testing And Commissioning Factory Assembled Cpri Approved Electrical Cubical Controlfeeder Panel Board Made Outdoor Type Feeder Pillar Box Double Door Type Weather And Vermin Proof Fabricatedout Of 3.15 Mm Crcasheet Of Suitable Size, 3 Phase 4 Wire 415 V, Ac, 50Hz Complete Duly Powder Coated Complete With Locking Arrangement, Earthing Termimal With Suitable Rating Copper Bus Bar For Incoming And Outgoing MccbS Includingmeasuring Instrument Such As Volt Meter, Ammeter, Selector Switch, Cts Phase Indicator Lamp With Holder, Toggle Switches And Backelite Fuse Cut Outs Etc Including Incoming And Outgoing Cables Connections With Suitable Cable Glands And End Termination Including Grouting Of Feeder Pillar Box 60 Cm Above Ground Level By Providing 90 Cm Long Angle Iron Size 50Mmx50mmx6mm Welded On All Four Corner Embedded In Pcc 1:2:4 Type B-1 Using 20Mm Graded Upto 30Cm Depth Complete All As Specified And Directed Including Sssssupply And Fixing The Following Accessories:- 108 ( A ) High Conductivity Copper Busbar Having Set Of 4 Strips, 4 Nos Tpn Of Suitable For 200 Amps Rating , Indicating Lamp ( Ryb ) For Phase And 1 No For Neutral Mounted On Dmc Support With Heat Shrink Sleeve-1 Set. ( B ) Phase Indication Lamp, Led Type ( Set Of 3 ) -1 Set ( C ) Ammeter Anolog Type Having Measuring Range ( 0-200 ) Amps With Cts Etc Including Rotary Switchto Measureload Of Each Phase : L&T / Seimens ( D ) Volt Meter Having Measuring Range ( 0-500 ) Volt With Rotary Switch To Measure Voltage Of Phase Make : L&T / Ae ( E ) Off Load Change Over Of Capacity 200 Amp, 4 Pole, 415 Volt:01 Nos. 109 ( F ) Incomming: Mccb 4 Pole 200 Amp 415 Volt Thermaladjustable , Type With 36 Ka Breaking Capacity & Spreader Both Side As Incomming Cotrol Device :01 Nos G ) Outgoing: Mccb 4 Pole 100 Amp 415 Voltthermal Adjustable , Type With 25 Ka Breaking Capacity & Spreader Both Side As Outgoing Cotrol Device :02 Nos ( H ) Mccb 4 Pole 63 Amp 415 Voltthermal Adjustable , Type With 16 Ka Breaking Capacity & Spreader Both Side As Outgoing Control Device :01 No

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-04-2024
2 15-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-04-2024
3 20-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail