| 1 | Dismantling carefullyeach panel of solar water heater capacity 1000 LPD (each panel of 100 LPD = 10 Nos) including hot and cold pipe line network,collection water tank located between the bldgs at 50 Armd Regtand shifting entire panels and connected water supply tanks, hot water collection tanks on the bldg roof (double storey) and reassembling, reinstallationall as specified and dirceted by Engr-in-charge.Note: 1 Any damage caused during shifting of panels on roof shall be made good by the contractor with replacement.2All Civil work and replacement and servicingshall be measured and paid separately |
| 2 | Dismantling carefullyeach panel of solar water heater capacity 200 LPDincluding hot and cold pipe line network,collection water tank located between the bldgs at 50 Armd Regtand shifting entire panels and connected water supply tanks, hot water collection tanks on the bldg roof (double storey) and reassembling, reinstallationall as specified and dirceted by Engr-in-charge.Note: 1 Any damage caused during shifting of panels on roof shall be made good by the contractor with replacement.2All Civil work and replacement and servicingshall be measured and paid separetly |
| 3 | Descaling of the collectors and hot water tank 1000 Ltrs Cap with the chemical solvent for removing all silt/rustcomplete and making the whole system leak proof complete all as specified and directed. |
| 4 | Descaling of the collectors and hot water tank 500 Ltrs Cap with the chemical solvent for removing all silt/rustcomplete and making the whole system leak proof complete all as specified and directed. |
| 5 | Descaling of the collectors and hot water tank 200 Ltrs Cap with the chemical solvent for removing all silt/rustcomplete and making the whole system leak proof complete all as specified and directed. |
| 6 | Descaling of the collectors and hot water tank 100 Ltrs Cap with the chemical solvent for removing all silt/rustcomplete and making the whole system leak proof complete all as specified and directed. |
| 7 | Supply, fabrication and fixing feeder pillarbox of size 500x 450x500 mmmade out of MS sheet of 2.0mm thick bent to shape & size factory made with welding, bending works suitable forand including 200 Amps ratedaluminium bus bars (length of bus bar not less than 40 cm) 4No\"s ,makingholes of any size and mounted on porcelain/epoxy based post insulators of appropriate sizewith suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC 1:2:4 Type B-1 below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping complete all as specified and directed. |
| 8 | Supply and fixing in repairs Heating element ISI markedcapacity3 KW suitable for the existing appliance as approved all as specified and directed. |
| 9 | Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 6 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 10 | Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 11 | Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 12 | Taking down unserviceable PVC rigid pipe and S&F heavy duty PVC rigid MMS pipe in concealed size25mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed.Make- Anchor or equivalent in Finolex, Supreme as approved. |
| 13 | Taking down unserviceablePVC rigid pipe and S&Fheavy duty PVC rigid MMS pipe in concealed size32 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed. Make- Anchor or equivalent in Finolex, supreme as approved. |
| 14 | Taking down unserviceable PVC rigid pipe and S&F heavy duty PVC MMS rigid pipe in concealed size40 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed.Make- Anchor or equivalent in Finolex, supreme as approved. |
| 15 | Supply and fixing for solar panel 550 Watt, 24 Volthaving 5 mm thick toughned glass size 6\"x4\" all as specified and directed. |
| 16 | Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for laying of LT/HT cable and getting out in any type of soil complete all as specified and directed. |
| 17 | Returning filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed. |
| 18 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point |
| 19 | Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed. |
| 20 | M & L for dry coarse sand as cushioning to cable 8 cm before laying HT/LT cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and directed. Note : For payment purpose, only punned thickness shall be measured. |
| 21 | M&L foraluminium sheet cladding of thickness 50 micron over hot pipe of 50mm dia for insulation incl binding clamp all as specified and directed. |
| 22 | Taking down old existing unserviceable sub main wiring and S&F new sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surfaceincluding cutting and cheasing and complete all as specified and directed.Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 23 | Dismantling allelectrical/water connection from IndustrialRO capacity 500 LPH and reconnect afterreplacement of following parts |
| 24 | Supply only 40x40 membrane capacity 500LPH ISI marked to suit the existing RO as approved all as specified and directed. |
| 25 | Supply only carbon and sand media as approved all as specified and directed. |
| 26 | Supply only20\" big blue candle all as specified and directed. |
| 27 | Supply and fixing Rotational moulded polyethylene water storage tanks capacity 1000 ltrs (cylindrical vertical with closed top) three layered hoisted and fixed in position incl taking down all as specified and directed. |
| 28 | Supply and fixing Rotational moulded polyethylene water storage tanks capacity 500 ltrs (cylindrical vertical with closed top) three layered hoisted and fixed in position all as specified and directed. |
| 29 | Lagging to pipes 25mm dia used in internal water supply or plumbing all round with,40 mm thick bonded mineral wool preformed ‘SNAP ON’pipe sections of density 144Kg/cum confirming to IS 9843 incl chicken mesh and wrapping with 0.01 mm thick aluminium foil all as specified and directed. |
| 30 | Lagging to pipes 40mm dia used in internal water supply or plumbing all round with,40 mm thick bonded mineral wool preformed ‘SNAP ON’pipe sections of density 144Kg/cum confirming to IS 9843 incl chicken mesh and wrapping with 0.01 mm thick aluminium foil all as specified and directed. |
| 31 | PCC 1:2:4 type B-2(using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete |
| 32 | S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165 all as specified and directed. |
| 33 | Supplying and fixing in repairs of CPVC pipes size 25mm dia SDR 11 & Plain CPVC SDR 11 fittings in walls/ceilings or in floors complete all as specified and directed. |
| 34 | Supply and fixing brass elbow size 25mm dia all as specified and directed. |
| 35 | Supply and fixing brass TEE size 25mm dia all as specified and directed. |
| 36 | Supply and fixing brass MTA/MBTA size 25mm dia all as specified and directed. |
| 37 | Supply and fixing brass FTA/FBTA size 25mm dia all as specified and directed. |
| 38 | Supply and fixing brass ball valve size 25mm dia all as specified and directed. |
| 39 | Supply and fixing brass unionsize 25mm dia all as specified and directed. |
| 40 | Supply and fixing brassTank adoptarsize 25mm dia all as specified and directed. |
| 41 | Supplying and fixing in repairs of CPVC pipes size 32mm dia SDR 11 & Plain CPVC SDR 11 in walls/ceilings or in floors complete all as specified and directed. |
| 42 | Supply and fixing brass elbow size 32mm dia all as specified and directed. |
| 43 | Supply and fixing brass TEE size 32mm dia all as specified and directed. |
| 44 | Supply and fixing brass MTA/MBTA size 32mm dia all as specified and directed. |
| 45 | Supply and fixing brass FTA/FBTA size 32mm dia all as specified and directed. |
| 46 | Supply and fixing brass ball valve size 32mm dia all as specified and directed. |
| 47 | Supply and fixing brass unionsize 32 mm dia all as specified and directed. |
| 48 | Supply and fixing brassTank adoptarsize 32 mm dia all as specified and directed. |
| 49 | Supplying and fixing in repairs of CPVC pipes size 20mm dia SDR 11 & Plain CPVC SDR 11 fittings in walls/ceilings or in floors complete all as specified and directed. |
| 50 | Supply and fixing brass elbow size 20mm dia all as specified and directed. |
| 51 | Supply and fixing brass TEE size 20mm dia all as specified and directed. |
| 52 | Supply and fixing brass MTA/MBTA size 20mm dia all as specified and directed. |
| 53 | Supply and fixing brass FTA/FBTA size 20mm dia all as specified and directed. |
| 54 | Supply and fixing brass ball valve size 20mm dia all as specified and directed. |
| 55 | Supply and fixing brass unionsize 20mm dia all as specified and directed. |
| 56 | Supply and fixing brassTank adoptarsize 20mm dia all as specified and directed. |
| 57 | Supply and installation in repairs, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing]. Make-Hensel/L&T/Schneider |
| 58 | INCOMER: |
| 59 | Main MCCB 250A 4Pole Breaking Capacity 36KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle– 1 No. |
| 60 | Digital VAF Meter with Volt,Amp, Frequency – 1 No |
| 61 | LED Indicator Lamp R,Y,B – 3 Nos |
| 62 | CT coils 200/5A – 3 Nos |
| 63 | Control Fuse – 3 Nos |
| 64 | Copper Bus Bar 300A TPN with Colour Seleve. |
| 65 | Outgoings |
| 66 | MCCB 125A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos. |
| 67 | MCCB 100A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 2 Nos. |
| 68 | MCCB 63A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 2 Nos. |
| 69 | Onload changeover switch 200A 4 Pole-01 Nos |
| 70 | Cleaning of internal wall/floors of RCC over head reservoirs of Capacity 25000 Gallon including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste by opening wash out valvesand applying caustic soda solution and one coat of lime wash internally includingcement base white wash on complete OH tank to external wall, bottom surface, pillar and painting of raising main pipe line and delivery line by black paintand writing work with one coat of synthetic enameled paint as per colour code specifying (a) date of cleaning (b) Next due date of cleaning(c) Capacity of tank etc,complete all as specified and as directed.NOTE :All precautionery measure such as safety belt, climbing rope etc to be taken by the contractor to safeguard human life while working on overhead reservoir. |
| 71 | Cleaning of internal wall/floors of RCC over head reservoirs of Capacity 50000 Gallon including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste by opening wash out valvesand applying caustic soda solution and one coat of lime wash internally includingcement base white wash to complete OH tank to external wall, bottom surface, pillar and painting of raising main pipe line and delivery line by black paintand writing work with one coat of synthetic enameled paint as per colour codespecifying (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank etc,complete all as specified and as directed. |
| 72 | Cleaning of internal wall/floors of RCC over head reservoirs of Capacity 100000 Gallon including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste by opening wash out valvesand applying caustic soda solution and one coat of lime wash internally includingcement base white wash to complete OH tank to external wall, bottom surface, pillar and painting of raising main pipe line and delivery line by black paintand writing work with one coat of synthetic enameled paint as per colour code specifying (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank etc,complete all as specified and as directed. |
| 73 | Cleaning of internal wallsfor underground or semi underground sump located at Stage III and Stage IV,Pump House ofCapacity 50000 Gallons. The work also includes washing with clean water and bleaching powder including scraping with wire brush on walls and floors & removing mud and grits & deposits etc throw out properly to a distance not exceeding 50m including cement base white washing of external wall and painting of raising main pipe line and delievery line by black paint and Writing the date of cleaning and due date of cleaning on a rectangular box of size 75cm x 50cm, wriing in white in colour on black back all as specified and as directed. |
| 74 | Cleaning of internal wallsfor underground or semi underground sump located at Stage I and Stage II,Pump House ofCapacity 100000 Gallons. The work also includes washing with clean water and bleaching powder including scraping with wire brush on walls and floors & removing mud and grits & deposits etc throw out properly to a distance not exceeding 50m including cement base white washing of external wall and painting of raising main pipe line and delievery line by black paint and Writing the date of cleaning and due date of cleaning on a rectangular box of size 75cm x 50cm, wriing in white in colour on black back all as specified and as directed. |
| 75 | Cleaning of internal wallsfor underground or semi underground sump located at Stage II,Pump House ofCapacity 200000 Gallons. The work also includes washing with clean water and bleaching powder including scraping with wire brush on walls and floors & removing mud and grits & deposits etc throw out properly to a distance not exceeding 50m including cement base white washing of external wall and painting of raising main pipe line and delievery line by black paint and Writing the date of cleaning and due date of cleaning on a rectangular box of size 75cm x 50cm, wriing in white in colour on black back all as specified and as directed. |
| 76 | Chlorine testing kit compete with test tubes, solution complete all as specified and directed. |
| 77 | Testing of waterfrom the approved govtlab authority’ andtest thefollowing perameter of water :-PH range, Total solids, total hardness, Floride, Nitrites, Nitrates, Lead Arsenic, Ammonia, Chlorides, Cadmium, Cyanide, Mercury Iron, Management, Surphate, Phernolic and submission the report to Deptt or as directed.Note :-Water collected in presence of medical staff / MES staff and empty collection sample bottle will be provided by the contractor |
| 78 | Supply & fixing Aviation obstruction light for overhead water storage tank or reservoir with LED lamp 1 watt(100 Nos) complete all as specified and directed by Engr-in-charge.Make: C&S Model No. LTAL100 of C&S or equivalent in Philips/Bajaj as approved. |
| 79 | S&F in replacement for water level indicator for over head tank and underground/semi underground sump comprising sensors for 10 levels indicators and features of alarm on low and high levels with indications. The system to have alarm by pass and different indication in case of alarm by pass including connecting to the nearest system by providing 2 core copper conductor cable 1.5Sqmm etc and taking out old unserviceable water level indicator all as directed by Engr-in-Charge.Note : Make shall be approved by GE before incorporation of the work. |
| 80 | Supplying, laying, jointing, connecting testing and commissioning of communication cable 10 core 0.5 Sqmm Each PVC sheathed heavy duty LT Copper Conductor cable complete including 16 SWG GI Wire for supporting the communication cable and binding both the GI wire and communication cable at 1 mtr gap including replacement of old unserviceable communicable cable of water level sensor of under ground sump or over head reservoir etc.Note : All precautionery safety measure shall be taken by Contractor for safeguard of human life while working on overhead reservoir or underground/semi-underground sump. |
| 81 | M & L for Fabrication of distribution header of size 250 mm dia MS pipe, min length -5 mtr , dead end from both side with blind plates duly bolted including welding work to cut pieces/ pipes made to shape for taking out number of incoming / Outgoing branches flanged type as given below with suitable sluice valves incl nuts bolts, washer, welding, bending, drilling holes for bolts in any shape or size as directed inclusive of one primer coat, one under coat and finish coat of paint as per existing complete including brick work with plastering 15mm thick in 1:6 cement mortar to support the header above ground level and necessary PCC work in 1:2:4 type B1 / hard standing all around complete all asspecified and directed. (Contractor must visit the site before quoting).Note : Sluice valve shall be paid under seperate relevant items.Rate for made to flanges, Tee, Elbow fitting etcare included in the quoted rates.(a) Nos of Incoming- 01 Nos, size- 150mm outlet (b) Nos of Outcoming- 04 Nos, size- 150mm outlet(c) Nos of Outcoming- 01 Nos, size- 100mm outlet |
| 82 | Supply and fixing in replacementsluice valve size 80mmcast ironISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed . |
| 83 | Supply and fixing in replacementsluice valve size 100mmcast ironISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed . |
| 84 | Supply and fixingin replacement sluice valve size 150mmcast ironISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed . |
| 85 | Supply and fixing in replacement sluice valve size 200mmcast ironISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed . |
| 86 | Supply and fixing in replacement non return valve 150 mm dia heavy duty both ends flanged ISI marked,class PN 1.6 complete with nuts, bolts washers etc complete all as specified and directed. |
| 87 | Supply and fixing in replacementnon return valve 100 mm dia heavy duty both ends flanged ISI marked,class PN 1.6 complete with nuts, bolts washers etc complete all as specified and directed. |
| 88 | Supply only chlorination chemical highly efficient (high strength) calcium based granular(65 to 70% chlorine content) disinfectant more stable than chlorine gas/bleaching powder high stable in sealed container for water treatment stability projected shelf life of chlorination of chemical must be one year with min loss of chlorine all as per the relevant IS. The contractor has to produce manufacturers distributor test certificate and purchase voucher Lot wise from authrozied dealer/company while supply of calcium based granual for the verification of genuiness of material. No material shall be accepted without test certificate. |
| 89 | M&L for painting and writing letters \"SAVE WATER\"in Black letter size 36\"X18\" on dome of over head water RCC tank and UG Sump , writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 80 mm size on external surface of wall with white synthetic enamel paint over black background ofany capacity over head tank and UG Sump all as directed. |
| 90 | M&L for smart water levelcontroller with sensor integrated via screw terminals with on field configuration for providing the option for underground sump and overhead tank each. Indication for 5sensor reading per tank each.( 0%, 25%,50%,75%,100%) display interface with 4.3\"\" TFT LCD Screen with 32 bitmicro controller unit , fixed resolution 480x 720 pixels operating temp for device20 to 70 deg celsius. The controller must support I/O based controls over 8 bit8051 base microcontroller unit with support for buzzer/Alarm at 25% and 100% capacity to operate ON/OFF operations manual overide option to overide the controls from auto mode. The enclousre is made of ABS material for IP protection as per relevant IS, All as approved by GE. |
| 91 | M&L for SS304 Horizontal magnetic float switch with SS pipe for sensor mounting (5 Nos sensor) all as specified and directed. |
| 92 | S&F 7 core copper signal cable 1 Sqmm with weather proofrubber coating all as specified and directed. |
| 93 | Supply and fixing Glow sign board made of acrylic sheet reactangular shape having lighting arrangement of superior quality of size 5\"x2\"x8\" showing installation Nomenclature as approvedmarked all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours. |
| 94 | S&F and Fabrication of angle stand made of angle size 50x50x6mm for Glow sign board, incl jointing of Tees,incl PCC all as specified and directed. |