Tender For Comprehensive Repair Maintenance Of Lt Panel, Earthings, Feeder Pillar Box, Lt Ug Cables, Transformer Items And Other Connected Items At Akhnoor Under Ge (North) Akhnoor, akhnoor-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Comprehensive Repair Maintenance Of Lt Panel, Earthings, Feeder Pillar Box, Lt Ug Cables, Transformer Items And Other Connected Items At Akhnoor Under Ge (North) Akhnoor. Submission Date for this Tender is 15-04-2024. Tanks and Cylinders Tenders in akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42988455
Corrigendum : Tender For Comprehensive Repair Maintenance Of Lt Panel, Earthings, Feeder Pillar Box, Lt Ug Cables, Transformer Items And Other Connected Items At Akhnoor Under Ge (North) Akhnoor
Open Tender
Indian
Jammu And Kashmir
akhnoor
15-04-2024

Tender Details

Tender For Comprehensive Repair Maintenance Of Lt Panel, Earthings, Feeder Pillar Box, Lt Ug Cables, Transformer Items And Other Connected Items At Akhnoor Under Ge ( North ) Akhnoor- 1 Taking Down Unsv Lt Distribution Panel And Supply, Installation And Fixing Transformer Protection Panel For 400Kva Transformer Made Out Of Grp, Glass-Fiber Reinforced Polyester Smc As Per En 14598-1-Up Fr2 Material With Protection Class Ip 54 In Accordance With Iec 60529 And Color Code Ral 7032 Completely Dyed In Mass And Box Shall Be Made Out Of Insulating, Slow-Burning And Self- Extinguishing Composite ( Polyester + Glass Fiber ) Characterized With Resistance To Atmospheric Agents ( Uv ) . Protection Class Ii ( En 61140 ) When Correctly Installed On The Base And Panel Internal Size Should Be Not Less Than 590Mm X 800Mm X 250 Mm. Grp Material Shall Be Anti-Corrosive Suitable For Saline Atmosphere And Have Ambient Temperatures Of -50°C Up To +120°C, Flammability Hb 40 A, B ( En 60695-11-10 ) , V-1. Glow Wire Tested At 960°C / 3 Mm As Per En 60695-2-12. The Dimensional Stability Under Heat Is More Than 200 °C As Per Iso 75-2 Method A. The Enclosure Is Halogen- Free, Resistant To Termites. Grp Cabinet Should Withstand Minimum Di-Electric Strength Of 130Kv / Cm As Per Iec 60243-1. 2 The Panel Box Shall Be Equipped With Grp Handle Lock With Three Point Locking Mechanism And The Provision To Insert Various Type Of Locking Cylinders Provided To Avoid Unauthorized Access. Rohs Directive ( Eu ) 2015 / 863 ( Extension To Directive 2011 / 65 / Eu ) , Reach Regulation ( Ec ) No. 1907 / 2006. The Panel Stand Angie Iron Of 50Mmx50mmx5mm And 6101A Grade Aluminium Bus-Bar With Heat Shrinkable Sleeves Of Size 50Mmx10mm, Tpn. Start / Stop Push Buttons, Auto / Manual Selector Switches, Wiring Of Panel With Suitable Size Of Copper Conductor Cable, Thimbles, Etc. Suitable For Fixing The Items / Materials Mentioned At Here-In-Below, Complete All As Specified And As Directed:- Make- Hensel / L&T / Schneider 3 Incoming:-I ) . Motorised Mccb With Electrical Motor Operator 630Amp 4 P 36 Ka With Adjustable Thermal And Adjustable Magnetic Released With Spreader Links - 1 Nos ( Transformer ) Legrand Cat Part Nos. 422009 And 026144 Or Equivalent In Schneider Nsx Or Abb Tmaxaccessires For Mccbs Such As Shunt Release And Undervoltage Relay As Required. ( Ii ) Led Indicator R / Y / B - 1 Sets ( Iii ) Multi-Functional Meter ( Volt, Amp, Frequency ) With 3 Nos Ct Coils 600 / 5A-1 No ( Iv ) Control Mcb Sp 2Amp-3 Nos ( V ) Sm 500 Relay Or Equivalent In Selec / L&T - 1 Nos ( Vi ) Digital Overcurrent Relay - 1 Nos ( Vii ) Single Phasing Protection Relays - 1Nos ( Viii ) On Delay Timer - 2 Nos ( Ix ) ) 8 Pin Relay - 2 Nos ( X ) Surge Protection Device For Mains Incomer T1+T2 4Pole ( Itotal 10 / 350-50Ka ) Legrand Cat Part 412273 Or Equivalent In Schneider / Obo - 1No. 4 Taking Down Unsv Distribution Panel And Supply, Installation And Fixing Transformer Protection Panel For 250Kva Made Out Of Grp, Glass-Fiber Reinforced Polyester Smc As Per En 14598-1-Up Fr2 Material With Protection Class Ip 54 In Accordance With Iec 60529 And Color Code Ral 7032 Completely Dyed In Mass And Box Shall Be Made Out Of Insulating, Slow-Burning And Self-Extinguishing Composite ( Polyester+ Glass Fiber ) Characterized With Resistance To Atmospheric Agents ( Uv ) . Protection Class Ii ( En 61140 ) When Correctly Installed On The Base And Panel Internal Size Should Be Not Less Than 590Mm X 800Mm X 250 Mm. Grp Material Shall Be Anti- Corrosive Suitable For Saline Atmosphere And Have Ambient Temperatures Of -50°C Up To +120°C, Flammability Hb 40 A, B ( En 60695-11-10 ) , V-1. Glow Wire Tested At 960°C / 3 Mm As Per En 60695-2-12. The Dimensional Stability Under Heat Is More Than 200 °C As Per Iso 75-2 Method A. The Enclosure Is Halogen-Free, Resistant To Termites. Grp Cabinet Should Withstand Minimum Di-Electric Strength Of 130Kv / Cm As Per Iec 60243- 1. 5 The Panel Box Shall Have Shall Be Equipped With Grp Handle Lock With Three Point Locking Mechanism And The Provision To Insert Various Type Of Locking Cylinders Provided To Avoid Unauthorized Access. Rohs Directive ( Eu ) 2015 / 863 ( Extension To Directive 2011 / 65 / Eu ) , Reach Regulation ( Ec ) No. 1907 / 2006. The Panel Stand Angle Iron Of 50X50x5mm And 6101A Grade Aluminium Bus-Bar With Heat Shrinkable Sleeves Of Size 50Mmx10mm, Tpn. Start / Stop Push Buttons, Auto / Manual Selector Switches, Wiring Of Panel With Suitable Size Of Copper Conductor Cable, Thimbles, Etc.C24 Suitable For Foxing The Items / Materials Mentioned At Here-In-Below, Complete All As Specified And As Directed.Make-Hensel / L&T / Schneiderincoming:-Motorised Mccb With Electrical Motor Operator 400Amp 4 P 36 Ka With Adjustable Thermal And Adjustable Magnetic Released With Spreader Links-1 Nos ( Transformer ) Legrand Cat Part Nos. 422007 And 026144 Or Equivalent In Schneider Nsx Or Abb Tmaxaccessires For Mccbs Such As Shunt Release And Under Voltage Relay As Required. 6 Led Indicator R / Y / B-1 Setsmulti-Functional Meter ( Volt, Amp, Frequency ) With 3 Nos Ct Coils 400 / 5A-1Nocontrol Mcb Sp 2Amp-3 Nossm 500 Relay Or Equivalent In Selec / L&T-1 Nosdigital Overcurrent Relay - 1 Nossingle Phasing Protection Relays 1Noson Delay Timer-2 Nos8 Pin Relay-2 Nossurge Protection Device For Mains Incomer T1+T2 4Pole ( Itotal 10 / 350=50Ka ) Legrand Cat Part 412273 Or Equivalent In Schneider / Obo - 1No. 7 Taking Down Old / Unsv Earthing And Earthing Complete With Galvanized Steel Earth Plate Electrode 600Mm X600mm X 6.3 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Normal Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Mtr Below Normal Ground Leel, Connecting To The Galvanised Earthing Lead Strip 32X6mm Size, By Means Of Bolts, Nuts, Heck Nuts And Washers Of Galvanized Iron And Earth Lead Protected By Provision Of Gi Medium Grade Pipe 65Mm Bore Incl Provision Of Concrete Pit In Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregates With 40Mm Thick Cover Of Rcc 1:2:4 Reinforced With Xpm ( Weight Not Less Than 4 Kg / Sqm ) And Frame Of Angle Iron 25X25x6mm With Lugs 02 Nos And With 6Mm Dia Ms Bar Handle Made To Shape Gl Medium Grade 20Mm Bore Pipe For Watering Perforated At Bottom 1.75 Metre Long Placed On Top Edge Of Earth Plate, Common Salt & Charcoal Filling, Test Point Made Out Of 40Mm X 8Mm Fl With Fixing Arrangement, Funnel, Wire Mesh And Earth Work In Soft / Loose Soil, Returning Filling In And Removal Of Surplus Soil To A Distance Not Exceeding 50 Mtrs, All As Per Electrical Plate No 5 Of Ssr-1991 Part I And Connected To Earth Test Point All As Specified Or Indicated Incl Testing On Completion. 8 Excavation In Tranches Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M Deep For Foundation Of Laying Cable Including Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 9 Returning Filling In Including Spreading Watering And Well Ramming In Layers Not Exc 25 Om Complete All As Specified. 10 Removing Surplus Soil To Distance Not Exceeding 50 M And Depositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point Complete All As Specified And Directed. 11 Protection To Cable With One Layer Of Brick Laid Flat Across The Cable Using Old Size Sub Class B Bricks All As Specified And Directed. 12 Sand Cushioning To Under Ground Cable, 8 Cms Thick Before Laying The Cable And 15 Cms Thick After Laying And Stretching The Cable In Trenches Including Hand Punning And Consolidating, Punned To 18Cm Thickness, Complete All As Specified And Directed. Note : For Payment Purpose, Only Punned Thickness Shall Be Measured. 13 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor. 1100 Volt Grade, Cross Sectional Area 120 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 14 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volt Grade, Cross Sectional Area 185 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 15 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volt Grade, Cross Sectional Area 240 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 16 Supply, Fabrication And Fixing Feeder Pillar Box In Replacement X Of Size 500X 450X500 Mm Made Out Of Ms Sheet Of 2.0Mm Thick Bent To Shape & Size Factory Made With Welding, Bending Works Suitable For And Including 200 Amps Rated Aluminium Bus Bars ( Length Of Bus Bar Not Less Than 40 Cm ) 4NoS Making Holes Of Any Size And Mounted On Porcelain / Epoxy Based Post Insulators Of Appropriate Size With Suitable Size Of Nuts, Bolts And Washers Complete With Mounting Leg Of Size 40Mmx40mmx5mm And Length Of Angle Iron Not Less Than 1 Mtr, 0.5 Mtr To Be Embeded In Pcc 1:2:4 Type B-1 Below G.L And 0.5 Mtr Above Ground Including Painting Of Complete Structure With Two Coats Of Super Enamelled Synthetic Paint Over A Coat Of Red Oxide And Incoming / Out Going Cable Connections With Required Size Of Cable Lugs With Proper Crimping.Make :- L&T, Legrand, Schneider, Hensel 17 Supply And Fixing In Replacement Of Ht Feeder Pillar Box Outdoor Type Factory Made Weather And Vermin Proof Made Out From 3.15 Mm Sheet Supported With Legs All Across The Panel Made Of Angle Iron 50Mmx50mmx5mm Of Size 1.2 Mtr X1 Mtr X1 Mtr With 3 Nos Required Length Aluminium Bus Bar Of Size 40X10mm Or 400 Amps For 11 Kv, 11 Kv Post Insulator 6 Nos Duly Drilled Hole For Ht Cable Connection Including Front And Rear Side Openable With Locking Arrangement Suitable For 11 Kv Ht And Provision For Incoming And Out Going Ht Cable Connection Including Painting With Two Coats Of Smoke Gray Synthetic Enamels Paint Over A Coat Of Red Oxide Primer Complete And Providing Security Fence Xpm Jally Type Of 2 Mtr Height From Ground Level Square Type All Rounded 2.5 Mtr Length With 9Nos Angle Iron Of 25X25x5mm Of Height 2.25Mtr ( 2Mtr Above Ground 0.25 Mtr Under Ground ) Including Necessary Location Gate Of Same Xpm Jally All As Specified And Directed.Note:- Feeder Piller Box Shall Be Mounted On Brick Platform Built In Pcc Not Less Then 60 Cm Above Ground Level With Suitable Pcc Foundation Rendering 15 Mm In Cm ( 1:6 ) , Applying Two Coats Of Cement Base Paints And Xpm Jally Supported On 9 Nos Angle Iron With Concrete Base. 18 Supply And Installation In Repairs, Commissioning And Testing Polycarbonate Asta Cpri Approved Oem Made Main Lt Panel. The Panel Shall Be Made Of Modular Polycarbonate Thermoplastic Enclosures Including Mccbs And Indicator Lamps Which Shall Be Uv Resistance In Accordance With Iec 61439-1, Clause 10.2.4: The Panel Shall Be Anti-Acid & Anti Corrosive. Degree Of Protection Against Mechanical Load Shall Be Ik08 ( 5 Joule ) In Accordance With Iec 62262. The Manufacturer Of Panel Shall Submit A Copy Of Asta Cpri Test Report In Polycarbonate Only Also Share Panel Assembled By Oem, Channel Partner Or Sister Concern Assembly Will Not Be Accepted. Degree Of Ingress Protection Ip 65 In Accordance With Iec 60529. The Gasket Shall Be Internally Embedded Made Of Polyurethane. The Panels Made By Approved Manufacturers Shall Submit A Copy Of Type Test Report Of A Board Made Out Of Polycarbonate Thermoplastic Panel In Accordance With Iec 60439-1. 19 The Asta Cpri Report Shall Have Mention Of Following Tests Performed And Passed Out Satisfactorily - Temperature Rise, Dielectric Properties, Short Circuit Withstand Current - Rated Peak & Short Time Withstand Current And Rated Conditional Short Circuit Current, Effectiveness Of Protective Circuits. The Board Manufacturer Shall Submit The Copy Of Type Test Reports For Polycarbonate Thermoplastic Board Only. Test Reports Submitted Of Other Material Of Construction Like Ms, Ss Will Not Be Applicable. Each Board Shall Have Individual Routine Test Report Of The Manufacturer. The Panel Shall Pass Glow Wire Test 960 Degrees Centigrade In Accordance With 60695-2-11 [ Flame Retardant And Self-Extinguishing ) . Make-Hensel / L&T / Schneider 20 Incomer:Main Mccb 250A 4Pole Breaking Capacity 36Ka Thermal And Magnetic Released With Spreader Links & Extended Rotary Handle-1 No. Make - Legrand Code No.6690 72 / Abb / Schnieder / L&T.Digital Vaf Meter With Volt, Amp, Frequency - 1 Noled Indicator Lamp R.Y, B-3 Nosct Coils 250 / 5A-3 Nos Control Fuse-3 Nos 21 Outgoings:-Mccb 125A 4Pole Breaking Capacity 25 Ka Thermal And Magnetic Released With Spreader Links & Rotary Handle - 1 Nos. Make - Legrand Code No.4200 16 / Abb / Schnieder / L&T.Mccb 100A 4Pole Breaking Capacity 16 Ka Thermal And Magnetic Released With Spreader Links & Rotary Handle-2 Nos. Make Legrand Code No.4200 15 / Abb / Schnieder / L&T.Mccb 63A 4Pole Breaking Capacity 16 Ka Thermal And Magnetic Released With Spreader Links & Rotary Handle-1 Nos. Make - Legrand Code No.4200 13 / Abb / Schnieder / L&T. 22 Supply And Installation In Replacement, Commissioning And Testing Polycarbonate Asta Cpri Approved Oem Made Main Lt Panel. The Panel Shall Be Made Of Modular Polycarbonate Thermoplastic Enclosures Including Mccbs And Indicator Lamps Which Shall Be Uv Resistance In Accordance With Iec 61439-1, Clause 10.2.4: The Panel Shall Be Anti-Acid & Anti Corrosive. Degree Of Protection Against Mechanical Load Shall Be Ik08 ( 5 Joule ) In Accordance With Iec 62262. The Manufacturer Of Panel Shall Submit A Copy Of Asta Cpri Test Report In Polycarbonate Only Also Share Panel Assembled By Oem, Channel Partner Or Sister Concern Assembly Will Not Be Accepted. Degree Of Ingress Protection Ip 65 In Accordance With Iec 60529. The Gasket Shall Be Internally Embedded Made Of Polyurethane. 23 The Panels Made By Approved Manufacturers Shall Submit A Copy Of Type Test Report Of A Board Made Out Of Polycarbonate Thermoplastic Panel In Accordance With Iec 60439-1. The Asta Cpri Report Shall Have Mention Of Following Tests Performed And Passed Out Satisfactorily - Temperature Rise, Dielectric Properties, Short Circuit Withstand Current-Rated Peak & Short Time Withstand Current And Rated Conditional Short Circuit Current, Effectiveness Of Protective Circuits. The Board Manufacturer Shall Submit The Copy Of Type Test Reports For Polycarbonate Thermoplastic Board Only. Test Reports Submitted Of Other Material Of Construction Like Ms, Ss Will Not Be Applicable. Each Board Shall Have Individual Routine Test Report Of The Manufacturer. The Panel Shall Pass Glow Wire Test 960 Degrees Centigrade In Accordance With 60695-2-11 [ Flame Retardant And Self-Extinguishing ) . Make-Hensel / L&T / Schneider 24 Incomer :Main Mccb 160A 4Pole Breaking Capacity 25Ka Thermal And Magnetic Released With Spreader Links & Rotary Handle-1 No. Make - Legrand Code No. 4200 57 / Abb / Schneider / L&T.Digital Vaf Meter With Volt, Amp, Frequency - 1 Noled Indicator Lamp R, Y, B-3 Nosct Coils 160 / 5A-3 Noscontrol Fuse-3 Nos 25 Outgoings :Mccb 125A 4Pole Breaking Capacity 25 Ka Thermal And Magnetic Released With Spreader Links & Rotary Handle - 1 Nos. Make - Legrand Code No.4200 16 / Abb / Schneider / L&T.Mccb 100A 4Pole Breaking Capacity 16 Ka Thermal And Magnetic Released With Spreader Links & Rotary Handle-2 Nos. Make - Legrand Code No.4200 15 / Abb / Schnieder / L&T.Mccb 63A 4Pole Breaking Capacity 16 Ka Thermal And Magnetic Released With Spreader Links & Rotary Handle-2 Nos. Make- Legrand Code No.4200 13 / Abb Schnieder / L&T. 26 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor. 1100 Volt Grade, Cross Sectional Area 6 Sqmm 2 Core Including Necessary Cable Lugs. Glands, Insulation Tape Etc Complete All As Specified And As Directed. 27 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor. 1100 Volt Grade, Cross Sectional Area 10 Sqmm 2 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 28 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor. 1100 Volt Grade, Cross Sectional Area 10 Sqmm 4 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 29 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor 1100 Volt Grade, Cross Sectional Area 16 Sqmm 4 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 30 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor. 1100 Volt Grade, Cross Sectional Area 16 Sqmm 2 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 31 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor. 1100 Volt Grade, Cross Sectional Area 25 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 32 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductable 1100 Volt Grade Cross Sectional Area 35 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 33 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor. 1100 Volt Grade, Cross Sectional Area 50 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 34 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor 1100 Volt Grade, Cross Sectional Area 70 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. . 35 Taking Down Burnt Cable And Supply, Laying, Jointing And Testing Xlpe Cable Insulated, Armoured, Earthed, Heavy Duty Electric Cable With Aluminium Conductor 1100 Volt Grade, Cross Sectional Area 95 Sqmm 3.5 Core Including Necessary Cable Lugs, Glands, Insulation Tape Etc Complete All As Specified And As Directed. 36 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Size Of 400 Sqmm Ug Cable Including Complete Connection And Crimping. Make-Jaipuriya / Rastriya / Dowells. 37 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ringterminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 300 Sqmm Ug Cable Including Complete Connection And Crimping. Make: Jaipuriya / Rastriya / Dowells. 38 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 240 Sqmm Ug Cable Including Complete Connection And Crimping. Make Jaipuriya / Rastriya / Dowells 39 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 185 Sqmm Ug Cable Including Complete Connection And Crimping. Make Jaipuriya / Rastriya / Dowells 40 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 150 Sqmm Ug Cable Including Complete Connection And Crimping. Make: Jaipuriya / Rastriya / Dowells. 41 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 120 Sqmm Ug Cable Including Complete Connection And Crimping. Make: Jaipuriya / Rastriya / Dowells. 42 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 95 Sqmm Ug Cable Including Complete Connection And Crimping. Make-Jaipuriya / Rastriya / Dowells. 43 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 50 Sqmm Ug Cable Including Complete Connection And Crimping. Make- Jaipuriya / Rastriya / Dowells. 44 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 35 Sqmm Ug Cable Including Complete Connection And Crimping. Make- Jaipuriya / Rastriya / Dowells. 45 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 25 Sqmm Ug Cable Including Complete Connection And Crimping. Make Jaipuriya / Rastriya / Dowells. 46 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bimetallic Terminals Etc Of Size 16 Sqmm Ug Cable Including Complete Connection And Crimping. Make-Jaipuriya / Rastriya / Dowells. 47 Replacement Of Aluminium Cable Thimbles / Line Connector / Pin Terminal / Ring Terminal / Insulated Ring Terminal / Fork Type Terminals / Bi-Metallic Terminals Etc Of Size 10 Sqmm Ug Cable Including Complete Connection And Crimping. Make-Jaipuriya / Rastriya / Dowells. 48 Cutting / Trimming / Chopping Of Tree Branches Along The Over Head Lines Of Lt Upto 5 Mtr From Elect Line On Both Sides Of The Span And Disposing Off The Cut Trees / Branches To A Distance Of N.Exc 50M And Clearing The Site As Directed . 49 Scraping Of Old Paint From Two Pole Structure Without Removing Accessories And Preparation Of Surfaces For Repainting. Repainting The Poles With One Coat Of Alternative White And Black Straps Of 30 Cm Each Upto 1.5 Mtr Height Using Synthetic Enamel Paint. Repainting The Remaining Iron Parts I.E. Cross Arms, Supporting Angles, Xpm Jali, Clamps, Gl Bkt Etc And Steel Pole Above 1.5 Mtr Height By Applying One Coat Of Aluminium Paint Or Pcc Pole With Snowcem Of Approved Color All As Required At Site Or Directed. 50 Restringing Of Over Head Line Acsr Of Any Size And Upto 5 Wires In A Span With Gi Earth Wire Of 4 Mm Dia Of Span Length 30 To 60 M To Permissible Sag Incl Pvc Line Spacer Winding With Aluminium Conductor And Triming Of Branches Of Tree Beside The Span All As Directed. Note Cost For Line Spacer In Between Span Is Included In Quoted Rates. 51 M&L For Fixing In Replacement Of Acsr Conductor Any Size Drawn Straight Horizontal On Over Head Lines On Existing Poles Including Binding With Insulators. Weight Of Conductor Shall Be Measured Straight Horizontal Distance Between Centre To Centre Of Two Adjacent Poles And Calculating Weight Of Conductor Of Size And Length By Adding 3% Extra For Sag, Jointing Jumpers, Etc Complete All As Specified And Directed By Engr- In-Charge. 52 Taking Down Unsv Pcc Poles And S&F Steel Tubular Swaged Pole Type 410 Sp-31 ( 9 Metre Long ) With 300 Mmx300mmx6mm Mild Steel Base Plate Continuously Welded To Pole, Finial Taper, Nut, Bolts And Screws All As Specified Including Factory Painted With Two Coats Of Black Bituminous Paint Internally Through Out And Externally For Embedded Portion And Applying One Coat Of Red Oxide Primer For The Remaining Portion And Two Coats Of Aluminium Paint Beyond 1.5M From Ground Level / Coping And Making 30Cm Black And White Strips With Two Coats Of Super Enameled Paint Up To 1.5M From Ground Level / Coping, Complete All As Specified And Directed. 53 Pcc 1:4:8 Type D-2 ( Using 40Mm Graded Crushed Stone Aggregate ) As In Foundation Filling And Mass Concrete All As Specified. 54 Pcc 1:3:6 Type C-1 ( Using 20Mm Graded Crushed Stone Aggregate ) As In Pole Coping Complete All As Specified And Directed Including Necessary From Work. 55 Supply And Fixing In Replacement Of Shackle Type Insulators, Porcelain, Vitreous, Brown Or Green Insulator Including Galvanised Mild Steel Straps, Washers, Insulators, Bolts, Washers And Nuts, Working Pressure 1100 Volts And Size Of 100 In Height And 115 Mm Dia Complete All As Specified And Directed. 56 Supplying And Fixing In Replacement Of Pin Type, Porcelin, Vitreour, White, Brown Or Green Insulator, Size 100 Mm Height, 65 Mm Dia For 1100 Volts Grade, Conforming To Is: 7321-1931, Complete All As Specified And As Directed. 57 M&L For Fixing In Replacement Of Stay Assembly Complete With Stay Plate Bow, Stay Rod Of Dia 16 Mm And Gavanised Iron Stay Wire Stranded Of Size 7 / 4Mm And Accessories As Shown In Electric Plate No 1 Of Ssr Part-I ( Loop Type Insulator, Stay Clamps, Excavation And Concrete Shall Be Measured Separately ) Complete All As Specified And Directed. 58 S&F Pvc Spacer 2 / 4 / 5 Way For Lt Over Head Line 1100 V Complete All As Specified And Directed. 59 Taking Down Old / Burnt Cable Of Any Size And Supply And Fixing Aerial Bunched Cable ( Ab ) Lt Of Size 3 Core- X16 Sqmm+1-Core X 16 Sqmm+ 1X25 Sqmm For Street Lights 16 Sqmm Phase Conductor Shall Be Of Aluminium Solid Round; Outer Diameters Shall Be Within The Limits. The Phase Conductor Shall Be Insulated With Black Weather Resistant High-Density Polyethylene ( Hdpe ) Suitable To 1100 V Insulation. The Insulated Conductors Shall Generally Conform To The Relevant Standards. Conductors The Properties Of The Aluminium Wires Before Stranding Shall Be Tensile Strength Not Less Than 90 N / Sq.Mm. Resistivity At 20 Deg. C Not Exceeding 0.02845Ohm / Sq.Mm / M ( V ) And One Bare Messenger Wire Shall Be Stranded Non Compacted Circular Aluminium Alloy Conductor All As Specified And Directed.Make- Havells, Gloster, Polycab, Kei. 60 Note:- The Following Hardware Fittings And Accessories Shall Be Used To Install Erect And Join The Ab Cable ( I ) Suspension Clamp With Eye Hook ( Ii ) Suspension Fittings And Corresponding Eye Hook ( Iii ) Dead Eye Fittings ( Iv ) Nylon Tie ( V ) Connectors 61 Taking Down Carefully Following Capacity Transformers From Four / Two Pole / Platform By Disconnecting All The Electrical Connection And Transporting The Same To Authorised Workshop Incl Draining Out The Transformer Oil In Clean Barrels, Opening The Top Cover, Taking Out The Defective / Burnt Ht / Lt Coil Out Of The Tank For Repair, Insulation Testing Of The Transformer Winding, Refilling The Transformer Oil After Checking Proper Dielectric Strength, Refitting The Top Cover And Other Accessories Including Painting Of The Transformer With Approved Colour All As Specified And Directed And Transporting The Transformer Back On Original Place In Installation And Securing Properly On Four / Two Pole / Platform And Making All Ht / Lt Connection To The Complete Satisfaction Of Engr- In-Charge All As Specified And Directed. 62 25 Kva To 150 Kva 63 Exceeding 150 Kva And Upto 500 Kva 64 Note:- ( A ) The Rates Are Inclusive Of Transportation Of Transformer From Site Of Installation To Authorised Workshop And Back Including T&P Required And All The Ht / Lt Winding Shall Be Measured And Paid Separately. ( B ) Standby Transformer Shall Be Arranged By Contractor At Their Own Cost To Avoid Failure Of Supply On Site And The Capacity Of Transformer Should Be Matched With Repaired Transformer. Penalty Charges @1000 / Day Shall Be Deducted On Fail Of Arrangement Of Standby Transformer. ( C ) Contractor Has To Submit The List Of Authorized Workshops For Full Satisfaction Of Engr-In Charge And Final Binding Shall Remain With The Engr-In-Charge. 65 M&L In Replacement Of Burnt Defective Lt Copper Coil Of Transformer With New One Made Out Of Suitable Size / Guage Of Copper Super Enameled Wire Of High Quality Matching With The Existing Impedence And Insulation All As Specified And Directed By Engr-In-Charge Suitable For Following Capacity:- 66 25 Kva To 150 Kva 67 Exceeding 150 Kva And Upto 500 Kva 68 M&L In Replacement Of Burnt Defective Ht Copper Coil Of Transformer With New One Made Out Of Suitable Size / Guage Of Copper Super Enameled Wire Of High Quality Matching With The Existing Impedence And Insulation All As Specified And Directed By Engr-In-Charge Suitable For Following Capacity:- 69 25 Kva To 150 Kva 70 Exceeding 150 Kva And Upto 500 Kva 71 Note :The Cost Of Coil Shall Be Inclusive Of Cost Of Varnish Insulating Paper And Other Insulating Materials And No Extra Payment Will Be Made For The Same. 72 Filtration, Heating And Dehydration Of Transformer Oil On Site By Using Filteration Machine And Ehv Grade Having Dielectric Strength Not Less Than 55 Kv With 2Mm Gap Including Removal Of All Moisture Dirt / Girth All As Specified And Directed By Engr-In- Charge.Note:-Filtration, Heating And Dehydration Of Transformer Oil Shall Be Carried Out On Site And Rate Quoted By Contractor Shall Deemed To Include For Arrangement Of Filtration Machine And Its Transportation To Various Locations Of Installation Of Transformer And Topping Of Oil. 73 Construction In Replacement Of Transformer Platform Size 3Mx2mx1m From Ground Incl Xpm Jalli Fabricated With Angle Size 50X50x6mm And Two Coat Of Aluminum Paint Over One Coat Of Red Oxide Incl Steps Plinth Protection And All Other Relevant Works Complete All As Specified. 74 Ht Bushing Assembly With Brass Nut, Stud, Washers And Insulators Suitable For Outdoor Type Transformer Capacity Of 25 Kva To 500 Kva. 75 Lt Bushing Assembly With Brass Nut, Stud, Washers And Insulators Suitable For Outdoor Type Transformer Capacity Of 25 Kva To 500 Kva. 76 Supply And Filling Transformer Oil Of Dielectric Strength Not Less Than 40 Kv With 4Mm Gap Of Discharge 2 Sec For Topping Up Of Transformer Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-