Purvanchal Vidyut Vitaran Nigam Limited has published Tender For Supply Of Materials And Erection For Increasing Capacity Of 33/11 Kv S/S Ajuwa, Devakharpur, Ghatmapur , Bharwari , Gopsahasa And Purkhas Distt. Kaushambi In Business Plan 2024-25 On Semi Turnkey Basis Under Edc Kaushambi. Submission Date for this Tender is 22-04-2024. Transmission Line Tenders in kaushambi Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 01-Apr-2024 | Date Extended | Date | 15-04-2024 |
2 | 15-Apr-2024 | Date Extension | Date | 22-04-2024 |
Sl. No. | Item Description |
1 | Increasing Capacity of 33/11 KV S/S Ajuwa (1x5 to 2x5) MVA and 33/11 KV S/S Devakharpur (1x5 to 2x5) MVA Distt.Kaushambi |
2 | ERECTION OF WORK AS PER RESSPO NORMS. |
3 | Erection of complete structure for 33 KV Bus Isolator in switch yard as per RESPO drawing. Work also includes construction of gantry Plinth of size 1.0x0.45x0.45 cum with cement,coarse sand and ballast in ratio 1:3:6 and Plastaring of plinth with cement & sand in ratio 1:4 including digging of Pits & backfilling,All Concreting material like cement,ballast,sand Labour & T&P etc.shall be provided by the contractor . 33 KV Bus Isolator and Structureprovided by the Department |
4 | Erection of complete structure for 33 KV lightening arrestor in switch yard. as per RESPO drawing. Work includes Erection of 3 Nos.33 KV Lightening arrestor, its fitting and mounting with care. Grouting of structure with L.C, of 1:3:6 construction of plinth size 0.90x0.45x 0.45 cum. plastering the plinth with cement mortar with cement and sand in ratio 1:4. Worksincludes cost of clamp concrete material, labour T&P and cement, which shall be provided by the contractor. 33 KV Lighting Arrester and Structureprovided by the Department |
5 | Erection of complete 33 KV VCBwith Single Control Pannel with structure in switchyard and grouting of VCB Structures. C.T. Structure by cement, sand, brick ballast mortar in ratio 1:3:4. Work includes complete fitting of VCB and C.T. on structure carefully with making all connections of control cable for operating the VCB and C.T. Only VCB, C.T., Battery and battery chargar and their structure shall be provided by the Department .All other item like cement, concrete material, T&P shall be provided by the contractor. Work also includes installation and commissioning of Battery and Battery charger. |
6 | Installation of 33 KV transformer control pannel in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. Work includs fitting of all accessories in all respect with complete connection of control cable with pannel.Grouting material will be provided by the Contractor. |
7 | Erection of complete structure for 33 KV post Insulators in Switch yard. Work includes Installation of 3 Nos. 33 KV Post Insulator on each structure complete as per schedule, grouting of Structure with Ist class brick ballast in the ratio of 1:3:6, plastering in the ratio of 1:3 on plinth size 0.90x0.45x0.45 Cum. The work is to be done strictly as per RESPO drawing. All the material likeCement, concrete material used for above work will be provided by the Contractor. 33 KV post Insulators and Structure provided by the Department. |
8 | Construction of complete T/F plinth size 4.46 x 3.46 x 1.0 Mtr. above the ground level and 0.5 Mtr. deep foundation made as per drawing. Top of plinth is to be L.C. work in the ratio of 1:3:6 fitted with 3 Mtr. long, 90 lbs, 2Nos. rail pieces. Cement mortar is to be used in 1:3 ratio. Cement, concrete material, bricks used in plinth shall be supplied by the contractor. 6” stone grit is to be laid before foundation start for whole plinth. Only Rail pieces shall be Provided by Department . Other material shall be provided by the contractor. |
9 | Safe shifting and mounting of 33/11 KV 5 MVA T/F on the transformer plinth. This work includesshifting, lifting and complete assembling after placing on the plinth.All special and ordinary T&P is to be arranged by the contractor. Special care is to be taken to avoid tilting of T/f and loss of transformer oil. Any damage in T/F will be chargeable to contractor. |
10 | Earthing of each Structure erected in the yard with 35x6 mm. G.I. strip in duplicate fully welded at both ends to be connected, necessary G.I. strip shall be provided by the contractor. |
11 | Earthing of 11 KV indoor equipments, switch gears as per RESPO Drawing. with G.I. Strip of Size 50x6 mm, provided by which will be the contractor. |
12 | Earthing of 33 KV C.T. Structure complete as per schedule with 50x6 mm.G.I. Strip. All earthing material shall be provided by the contractor. |
13 | Special earthing of lightening arrestor structure with 6 Nos. additional 40 mm dia 2.5 Mtr. Long G.I. pipe electrodes/rod by digging 3 Mtr. deep pits and connecting it with L.A. through G.I. Strip 35x6 mm welded at both ends. All the material Like G.I. pipe, G.I. strip shall be provided by the contractor. |
14 | Delta earthing of T/F neutral by boring 2” dia 20 feet long G.I. pipe in the wet earth and connecting it with 35x6 mm. G.I. strip to T/F neutral giving half round turn at the T/F. Two separate chemical As per standard procedureearthing to be provided to T/F body by connecting it with earth mat by special earthing arrangement for earthing work. Material Like Strip of size 50x6/35x6 mm and G.I. pipe 2” dia 2.9 mm thick shall be provided by the contractor used in above work. |
15 | Laying and stringing of ACSR dog conductor for busbar between busbar gantry as well as terminal gantry. Three phase jumpering from bus to bar L.A, VCB, C.T., Post insulator and 33/11 KV T/F, Terminal Gantry, Isolator etc. properly with jumpering with P.G. Clamp, T. Clamp and Post Insulator clamp, P.G. clamp, T.clamp,and any other clamp required for jumpering shall be provided by the contractor. Only A.C.S.R. Dog conductor Provided by the Department |
16 | Painting of All structure and equipment inside the switch yard with two coats of red oxide primer and thereafter two coats of aluminium paint, giving silver white finish, painting is to be done after proper cleaning of the structures. paint, primer, thinner etc. required shall be provided by the contractor himself. |
17 | Installation of 11 KV VCB in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. Fixing of 11 KV switchgears rag bolt, mounting ofP.T. on incoming. |
18 | 11 KV In coming |
19 | 11 KV O/G VCB |
20 | Laying of 11 KV 3 x 120/185/300 Sqmm. XLPE power cable by digging 0.75 Mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it RMT and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, will be provided by the contractor. Rates may be quoted per RMT |
21 | Erection of 2No. D/pole 8.5 Mtr. PCCpole including fixing of Top channel on the top the pole and cross brasing, with the help of clamp for 11 KV outgoing feeder of 33/11 KV S/S all material required for this work shall be provided by Department |
22 | Termination of cable boxes of size 3 x 300 Sqmm. for XLPE cable Boxes I/D & O/G will be of Heat Shrink indoor type andoutdoor type cable boxes will be provided by the contractor |
23 | Termination of cable boxes of size 3 x120/185 Sqmm. for XLPE cable Boxes I/D & O/Gwill be of Heat Shrink indoor type andoutdoor type cable boxes will be provided by the contractor |
24 | Fabrication and fixing of cable support channel of size 125 x 65 x 6mm. 3.5 Mtr. long and grouting with mortar 1:3:6 ratio in switch yard.All the material , shall be provided by the contractor. |
25 | Fabrication and fixing of neutral strip support of T/F made of 65x65x6mm. 3.5 mtr. long and grouting with mortar 1:3:6 ratio in switch yard.All the material such as cement, concrete except strip shall be provided by the contractor. |
26 | Laying of following copper control cable form C.T. T/F to transformer control pannel/protection Board. All control cable shall be supplied by the contractor. |
27 | 2x2.5 mm2 |
28 | 4x2.5 mm2 |
29 | Cartage of all abovematerials will be done by Contractor from Naini Store, Prayagraj to Sub Station Kaushambi |
30 | Increasing Capacity of 33/11 KV S/S Ghatmapur (1x5 to 1x10) MVA, 33/11 KV S/S Bharwari (1x5 to 1x10) MVA and 33/11 KV S/S Gopsahasa (2x5 to 2x10) MVA and33/11 KV S/S Purkhas (3x5 to 2x5+1x10) MVA Distt.Kaushambi |
31 | Erection of complete 33 KV VCB with Single Control Pannel with structure in switchyard and grouting of VCB Structures. C.T. Structure by cement, sand, brick ballast mortar in ratio 1:3:4. Work includes complete fitting of VCB and C.T. on structure carefully with making all connections of control cable for operating the VCB and C.T. Only VCB, C.T., Battery and battery chargar and their structure shall be provided by the department. All other item like cement, concrete material, T&P shall be provided by the contractor. Work also includes installation and commissioning of Battery and Battery charger. |
32 | Installation of 33 KV transformer control pannel in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. Work includs fitting of all accessories in all respect with complete connection of control cable with pannel.Grouting material will be provided by the Contractor. |
33 | Repairing of Existing T/F plinth size 4.46 x 3.46 x 1.0 Mtr. |
34 | Dismantling ofSwitchyard fencing for safe shifting of old 5 MVA power T/Fs |
35 | Safe Shifting & dragging of old 5/8 MVA T/F from inside to out side of Switch Yard after detaching its accessories i.e. Radiator, conservator etc and empting the T/F i.e taking out the T/F oil and disconnecting all 33 KV and 11 KV connections as well as dismantling of 11 KV cable stand and neutral stand.All tools & T&P shall be provided by the contractor. |
36 | Safe shifting and dragging of 5/8/10 MVA Power Transformer from outside of Switch Yard to inside of Switch Yard taking precautions to avoid damage of bushings of Transformer and other accessories. All tools, T&P etc shall be provided by the contractor. |
37 | Erection of 5/8/10 MVA Power Transformers on plinth, fixing of all accessories like radiator, conservator tank etc. complete and filling of T/F oil in Transformer complete in all respect. |
38 | Special earthing of neutral and body of 5/10MVA T/F with the help of 3 Nos.G.I. pipe 40 M.M. dia. length 20 feet. G.I.pipe for making of delta, and 2 nos for body earthing complete in all respect and connected with 50x6 m.m GI Strip. G.I. Pipe,G.I. Strip etc. required for completion of work in all respect shall be provided by the Contractor. |
39 | Earthing of 11 KV indoor equipments, switch gears as per RESPO Drawing. with G.I. Strip of Size 50x6 mm, provided by which will be the contractor. |
40 | Laying of 11 KV 3 x /120/185/300 Sqmm. XLPE power cable by digging 0.75 Mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it RMT and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be provided by the contractor. Rates may be quoted per RMT |
41 | Cartage of materials from store center Naini to site, like all Sub station structure, 11 KV Switch gears, Earth mat material, poles, station T/F, All Equipment (TPMO, LA, Fuse set, C.T, P.T. Isolators, VCB, Conductor, Cable, etc.) |
42 | 11 KV 3 x 120/185/300 Sqmm. Joniting Kits |
43 | Indoor |
44 | Outdoor |
45 | Laying of following copper control cable form C.T. T/F to transformer control pannel/protection Board. All control cable shall be supplied by the contractor. |
46 | 2x2.5 mm2 |
47 | 4x2.5 mm2 |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy