Tender For Replacement Of Old High Wall Type Air Conditioners In Control Room At Chatham Power House, Port Blair, port Blair-Andaman And Nicobar Islands

Andaman Public Works Dept-APWD has published Tender For Replacement Of Old High Wall Type Air Conditioners In Control Room At Chatham Power House, Port Blair. Submission Date for this Tender is 19-03-2024. Air Conditioner Tenders in port Blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

42954930
Tender For Replacement Of Old High Wall Type Air Conditioners In Control Room At Chatham Power House, Port Blair
Open Tender
Indian
Andaman And Nicobar Islands
port Blair
19-03-2024

Tender Details

Replacement Of Old High Wall Type Air Conditioners In Control Room At Chatham Power House, Port Blair

Key Value

Document Fees
Refer document
EMD
INR 6814.0 /-
Tender Value
INR 3.40 Lakhs /-

BOQ Items

Name of Work: Replacement of old high wall type Air conditioners in control room at Chatham Power House, Port Blair.
Sl. No. Item Description
1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
24 X 4 sq. mm + 2 X 4 sq. mm earth wire
3Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduitas required.(Drain pipes for IDU of AC)
425 mm
5Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator).
66 way (4 + 18), Double door
7Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
8Triple pole
9Triple pole and neutral
10Supply and fixing of MCB enclosure of sheet steel, phosphatisd,power painted MCB DB,s with Din rail ( in accordance with IS 1302, IS8623, IEC/BSEN 60439-3). Of4 ways Havells CAT NO DHDESFP or equivalent
11SITC ofminimum 03 Ton capacity high wall type split air conditioner, Reciprocating Compressor, 3 Phase,415V)with minimum 10200 Watts cooling capacity MAKE: Blue star Model FMA36AAMUP3, or equivalent. (Condenser coil must be of copper .)
12Providing and fixingof refrigerant copperpipes of following sizes (Suction & delivery) of split type AC i/c providing electrical cables, insulation, drain pipe, extra gas charging , cutting, drilling holes on the wall for passing gas pipes , fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish and covering with PVC non adhessive tape over the insulation of refrigerant pipes and as per the direction of E-in-C
13Refrigerant pipes of Sizes 3/4" & 1/2"
14Fabrication of stand/Pedestal for keeping the indoor/out door unit of split type AC of various capacity made ofsuitable size ofM S Angle and painting with one coat of red oxide and paintas required.