Tender For Contingency Work For Replacement Of Inefficient And Stand By Submersible Mono Block Pump Sets And Old Polluted And Damaged Pipe Line At Rwss Sangariya Under Sub Div Shahpura, shahpura-Rajasthan

Public Health Engineering Department-PHED has published Tender For Contingency Work For Replacement Of Inefficient And Stand By Submersible Mono Block Pump Sets And Old Polluted And Damaged Pipe Line At Rwss Sangariya Under Sub Div Shahpura. Submission Date for this Tender is 21-03-2024. Pump repair and Maintenance Tenders in shahpura Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42927195
Tender For Contingency Work For Replacement Of Inefficient And Stand By Submersible Mono Block Pump Sets And Old Polluted And Damaged Pipe Line At Rwss Sangariya Under Sub Div Shahpura
Open Tender
Indian
Rajasthan
shahpura
21-03-2024

Tender Details

Contingency Work For Replacement Of Inefficient And Stand By Submersible Mono Block Pump Sets And Old Polluted And Damaged Pipe Line At Rwss Sangariya Under Sub Div Shahpura

Key Value

Document Fees
INR 500 /-
EMD
INR 10200.0 /-
Tender Value
INR 5.10 Lakhs /-

BOQ Items

Name of Work: Contingency work for Replacement of inefficient and stand by Submersible mono block pump sets and old polluted and Damaged pipe line at RWSS Sangariya under sub div shahpura.
Sl. No. Item Description
1Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer"s design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
27.5 KW (10 HP)
3Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
4Above 10 HP and up to 15 HP
5Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc.
63 core 6.0 Sq.mm
7Supply&FixingXLPEinsulated/P.V.C.sheathedcableof1.1KVgradewith aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground asperIS:1255includingexcavationof30cmx75cmsizetrench,25cmthick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
816.0 Sq.mm, 4 core
9Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge.
10MS pipespecialsup to600mmdia (withminimum5mmthickness sheet)
11Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
12Manually Operated CI Sluice valve of Class PN-1.0
13100 mm HW
14Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.
15HDPE PE-80PN-6
1690 mm dia
17110 mm dia
18Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
1950 mm dia
20Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail