Tender For Repair/ Maintenance Of Certain External Electric Services, Water Supply Services And Other External E/M Services For J-1 And J-2 Loc Under Ge (East) Jalandhar Cantt, jalandhar-Punjab

Military Engineer Services-MES has published Tender For Repair/ Maintenance Of Certain External Electric Services, Water Supply Services And Other External E/M Services For J-1 And J-2 Loc Under Ge (East) Jalandhar Cantt. Submission Date for this Tender is 11-04-2024. Electrical Maintenance Tenders in jalandhar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42913474
Corrigendum : Tender For Repair/ Maintenance Of Certain External Electric Services, Water Supply Services And Other External E/M Services For J-1 And J-2 Loc Under Ge (East) Jalandhar Cantt
Open Tender
Indian
Punjab
jalandhar
11-04-2024

Tender Details

Tender For Repair/ Maintenance Of Certain External Electric Services, Water Supply Services And Other External E/M Services For J-1 And J-2 Loc Under Ge (East) Jalandhar Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

BOQ Items

Name of Work : Repair/ maint of certain external electric services, water supply services and other external E/M services for J-1 & J-2 Loc under GE (East) Jalandhar Cantt (Tender ID No 2024_MES_646518_1)
Sl. No. Item Description
1Taking up/ out burnt unserviceable LT cable off sizes from trenches including disconnecting all electrical connections, keeping aside old cable cover/ bricks for re-use, pulling out through pipes, under roads complete all as required at site as directed by Engineer-in-Charge.
2Supply and fixing in replacement galvanised pipe light grade of 100mm bore for passing of cable fixed to poles/walls/laid under floor/ roads complete with and including fittings as required compete all as specified and directed Engineer-in-Charge
3All as per Srl item No. 2.00 here-in-before but of size 80 mm bore
4All as per Srl item No. 2.00 here-in-before but of size 50 mm bore
5All as per Srl item No. 2.00 here-in-before but of size 40 mm bore
6Supply, laying, jointing and testing XLPEinsulated and PVC sheathed steel strip/wire armoured cable, LT 1100 volt grade (heavy duty) with stranded aluminium conductor of size 6 Sqmm 2 core laid in trenches, in floor, in duct, through pipes or along the pole/along wall complete all as specified and directed by Engineer-in-Charge
7All as per Srl item No. 6.00 here-in-before but of size 10 sqmm 2 core
8All as per Srl item No. 6.00 here-in-before but of size 16 sqmm 4 core
9All as per Srl item No. 6.00 here-in-before but of size 25 sqmm 3.5 core
10All as per Srl item No. 6.00 here-in-before but of size 35 sqmm 3.5 core
11All as per Srl item No. 6.00 here-in-before but of size 50 sqmm 3.5 core
12All as per Srl item No. 6.00 here-in-before but of size 70 sqmm 3.5 core
13All as per Srl item No. 6.00 here-in-before but of size 95 sqmm 3.5 core
14All as per Srl item No. 6.00 here-in-before but of size 185 sqmm 3.5 core
15Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and gettingout complete all as specifiedand directed by Engineer-in-Charge.
16Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed by Engineer-in-Charge
17Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed by Engineer-in-Charge.
18Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches punned down to thickness of 18mm complete all as specified.
19Supply & laying of old size sub class "B" bricks laid flat in trenches over the cable with the length of brickperpendicular to the directionof cable length, adjacent/abutting each othercomplete all as specified and directed by Engineer-in-charge.
20Labour for laying of old bricks/cable retrieved in item No 1.00 complete including laying bricks/ covers flat in trenches over the cable with length of brick perpendicular to direction of cable complete all as specified and directed
21Material and labour for replacement earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres belownormalgroundlevel,connected with and including GI strip 32mm x 6mm from earth plate to test point and aluminium strip 25 x 3.15 mm from test point to equipment in andincluding GI pipe 40 mm bore light grade as protection pipe (from top of earth plate) by means ofbolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around includingtop and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level) in (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate of 25mm thick with 1 No MS handles of 6/8 mm dia including test point made of GI strip 32X6mm necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified
22Material and labour for replacement earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres belownormalgroundlevel,connected with and including GI wire 4 mm from earth plate to test point and from test point to equipment in andincluding GI pipe 15 mm bore light grade as protection pipe (from top of earth plate) by means ofbolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around includingtop and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level) in (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate of 25mm thick with 1 No MS handles of 6/8 mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified
23Material and labour for scraping old paint from LT panels/ feeder pillars inner & outside off size with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint of shade as approved by Engineer-in-charge with spray machine gun from top of PCC coping and marking number/ name of panel and feeders in alphabets not less than 50mm in size complete all as specified & directed by Engineer-in-Charge
24Material and labour for preparation of old painted surface of steel tubular poles any type with swan neck/ straight type/ with bracket and applying one coat of aluminium oxide paint to complete pole of height 9 mtrs complete including applying two coats of synthetic enamel paint in black & white alternate strips of 30cm each up to 1.5 mtr height from top of PCC coping and numbering of poles in alphabets of size not less than 100 mm height all as specified & directed by Engineer-in-Charge. Note : Colour for base of board and alphabets shall be decided by Engineer-in-Charge
25Supply and fixing in repair post top lantern having powder coated die cast and spun aluminium body with clear/ opal diffuser of 25 watt min complete including connecting with 3 core copper conductor cable all as specified and directedby Engineer-in-Charge
26Material and labour in repair for MCCB 400 Amps, 4 pole, adjustable thermal magnetic release, 35 KA, Ics=Icu=100%with phase extenders / copper links and phase separator / phase barrier complete including taking out old UNSV MCCB of any type all as specified and directed
27Material and labour in repair for MCCB 250 Amps, 4 pole, adjustable thermal magnetic release, 35 KA, Ics=Icu=100%with phase extenders / copper links and phase separator / phase barrier complete including taking out old UNSV MCCB of any type all as specified and directed
28Material and labour in repair for MCCB 200 Amps, 4 pole, adjustable thermal magnetic release, 25 KA, Ics=Icu=100%with phase extenders / copper links and phase separator / phase barrier complete including taking out old UNSV MCCB of any type all as specified and directed.
29Material and labour in repair for MCCB 100 Amps, 4 pole, adjustable thermal magnetic release, 16 KA, Ics=Icu=100%with phase extenders / copper links and phase separator / phase barrier complete including taking out old UNSV MCCB of any type all as specified and directed. Make for Srl item No. 26.00 to 29.00 : Schneider/ Legrand/L&T/Havells / ABB/ Siemens/C&S/ HPL
30Material and labour in repair for digital ammeter, programmable type 96x96mm complete all as specified and directed.
31Supply and fixing in repair Astronomical Digital timer switch for switching on/off lights according to rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/ or fixed preset time, current capacity 16A with 1 changeover (1 C /O ), Total 28 programs min complete in powder coated CRCA sheet enclosure/ thermoplastic enclosure of suitable thickness with MCB TPN 32 Amp - 02 nos, 3 pole contactor 32 Amp - 01 No and MCB single pole - 01 nos for manual switching of lights, fixing arrangement i.e. DIN rail complete with necessary porcelain/ DMC insulator for incoming and outgoing cable connections with reqd clamp duly painted to fix on pole complete all as specified and directed. Make of timer switch : Indoasian / Siemens /Schneider/ L&T/ Legrand /Havells / GIC
32Supply and fixing in repair SMC/ polycarbonate material made junction box of minimum size 300 x 200 x 105 mm includingside hingessuitable for pole mounting arrangements having front hingedwith lockable arrangements, outdoor type, weather proof having the provision to connect incoming and outgoing cable of size 16 sqmm 2 core and one number MCB SP 10 KA, C-curve. 6 Amps, 240 Volts and suitable fixing clamp complete all as specified and directed
33Material and labour for Steel tubular swaged poles complete with base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including painting of poles upto 1.5 mtr height from coping with two coats of synthetic enamel paint black & white strips and numbering of poles as directed complete all as specified and directed. (PCC and earth work shall be measured & paid for separately).
34Material and labour for SPD 10 kv suitable for street light / flood light fitting of cap 70 watt to 200 watt complete all as specified and directed
35Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driverhaving protection against over voltage, short circuit and open circuit,voltage band 100 volts to 270 volt, power factor 0.90 suitable for LED street light of capacity 45 W to 60 watt complete all as specified and directed.
36Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driverhaving protection against over voltage, short circuit and open circuit,voltage band 150 volts to 270 volt, power factor 0.95 suitable for LED street light of capacity 90 w to 120 W complete all as specified and directed.
37Material and labour for replacement of TPN MCB, 240 Volts, 50 Hz, having10 KA rupturing capacity of rating 25 Amps complete all as specified and directed
38Material and labour for replacing TPN MCB, 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 40 Amps complete all as specified and directed.
39Material and labour Dehydration and filtration of existing transformer oil using transformer oil filtration cum dehydration plant to eliminate foreign particles and to improve di-electric strength upto 60 KV (min) in 2.5mm electrode gap and to bring the acidity within the permissible limit below 0.5 mg KOH / Cm complete all as specified and directed. The Record of di-electric strength of insulating oil achieved after dehydration shall be given in writing by the contractor to the dept
40Supply & filling of transformer insulation oil for topping up the level of oil having di-electric strength 60 KV (minimum) at a electrode gap of 2.5mm upto the required level of transformer and testing of di-electric strength of oil in transformer before and after filling. Make : Power/ Servo/ Insole/ Universal/ Savita/ Castrol conforming to relevant IS-335. Note :- Transformer oil be supplied in sealed containers
41Supply & filling in replacement of breather assembly (transparent type ) heavy duty/ superior quality 500gm and fixing properly with transformer complete all as specified.
42Material and labour for detecting leakage from top cover oftransformer complete by removing , scraping of old worn out top gasket of main tank and fixing of new cork gasket sheet on the tank top cover 6.0 mm thick and pasted by using suitable adhesive for the transformer of any type / make of capacityof 400 to 630 KVA including fixing the top cover with conservator, making HT & LT connections at site complete all as specified
43Material and labour for replacement of copper cable for connection in LT panels for metering and CTs of size 4 sqmm single core duly crimped with copper thimbles all as specified and directed (Cost of copper thimbles and crimping included).
44Material and labour for replacement of copper cable for connection in LT panels for metering and CTs of size 2.5 sqmm single core duly crimped with copper thimbles all as specified and directed (Cost of copper thimbles and crimping included).
45Material and labour for replacement of copper cable for connection in LT panels for metering and CTs of size 1.5 sqmm single core duly crimped with copper thimbles all as specified and directed (Cost of copper thimbles and crimping included).
46Supply and fixing in repair LED Flood light fitting 150 watts, made up of pressure die-cast aluminium housing with toughened clear glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W, potted Constant Current driver moisture resistant, with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and separate Surge protection device 10 KV complete having fixing bracket clamp. Notes : (i) The old unserviceable LED fitting shall be issued after deducting amount as per Sch of credit at the time of RAR. (ii) The old unserviceable light fitting may be of lower wattage/ old specifications, no claim will be entertained on this account
47Supply and fixing in repairLED street light fitting 60 watts, made up of pressure die-cast aluminium housing with toughened clear glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W, having external potted Constant Current driver moisture resistant (installed in separate independent compartment) with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and with separate external Surge protection device 10 KV suitable for fitting on 32/40mm dia bore pipe bracket including making connections with PVC insulated 3 core copper conductor cable 0.75 Sqmm min of suitable length complete all as specified . Notes : (i) The old unserviceable LED fitting shall be issued after deducting amount as per Sch of credit at the time of RAR. (ii) The old unserviceable light fitting may be of lower wattage/ old specifications, no claim will be entertained on this account.
48Material and labour for Cable Jointing Kit for 11 KV grade earthed cable for indoor type termination cold shrinkable joint complete with jointing material, thimble and accessories suitable for XLPE insulated, screened, armoured aluminum conductor cable of size 95 sqm to150 sqmm 3 core incl opening cable connections/ taking down, taking old unserviceable joint kit and re-fixing cable complete all as specified and directed.
49Material and labour for Locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE HT/LT underground power cables of the rating 11/1.1 KV with the help of Pre-locator with time domain laptop based reflectometer/ electrometer using pulse echo method, impulse current method & decay method, and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of fault location necessary excavation and taking out of faulty cable for repair/ replacement of joint, relaying of cable/ cover & brick protection, refilling of soil and removal of surplus soil etc at Jalandhar Cantt all as specified and directed. Note: The joint shall be measured and paid separately under relevant item. The qty of item will be executed at different times during currency of contract as directed by Engineer-in-Charge. Hence, contractor shall quote his rate accordingly for arranging and executing the items accordingly. A penalty of Rs 2000/- will be levied, in case contractor fails to arrange machine within 24 hrs of intimation by Deptt.
50Material and labour in repair for PVC insulated PVC sheathed service cable twin core having aluminium conductor of size 10 sqmm 2 core complete
51Material and labour in repair for PVC insulated PVC sheathed service cable twin core having aluminium conductor of size 6 sqmm 2 core complete
52Material and labour for resin cast current transformer 11kvvoltage, ratio 60/5-5,dry type, insulation level 28 kv / 75 kVp, HSV :12KV, STC:18.4KA / 3sec and FREQ : 50Hz indoor type wound type ratio as core No 1. 60/5A, VA 15, class 1.0 and as core No 2 Ratio 60/5A, VA10, class 5P, ALF 10 complete shape all as per existing and specified and directed by Engineer-in-Charge .
53Material and labour for resin cast Voltagetransformer 11kv voltage 11KV/ Sqrt3 / 110V/ Sqrt3 / 110V/ 3, dry type insulation IL 12 kv/ 28KV / 75 kVp, HSV :12KV, FREQ : 50Hz indoor type wound type insulation class B, VA 100 & class 1.0 for first core and VA 50 and class 3P for second coreall as per existing shape all asspecified and directed by Engineer-in-Charge .
54Material and labour for heat shrinkable end jointing kit suitable for 1100 volts XLPE insulated PVC sheathed armoured aluminium conductor cable of size 70 sqmm 3.5 core complete incl opening and re-connections all as required at site.
55Material and labour for heat shrinkable end jointing kit suitable for 1100 volts XLPE insulated PVC sheathed armoured aluminium conductor cable of size 50 sqmm 3.5 core complete incl opening and re-connections all as required at site.
56Material and labour for heat shrinkable end jointing kit suitable for 1100 volts XLPE insulated PVC sheathed armoured aluminium conductor cable of size 35 sqmm 3.5 core complete incl opening and re-connections all as required at site.
57Material and labour for heat shrinkable end jointing kit suitable for 1100 volts XLPE insulated PVC sheathed armoured aluminium conductor cable of size 25 sqmm 3.5 core complete incl opening and re-connections all as required at site.
58Material and labour for heat shrinkable end jointing kit suitable for 1100 volts XLPE insulated PVC sheathed armoured aluminium conductor cable of size 16 sqmm 4 core complete incl opening and re-connections all as required at site.
59Material and labour for heat shrinkable end jointing kit suitable for 1100 volts XLPE insulated PVC sheathed armoured aluminium conductor cable of size 6 sqmm 2 core complete incl opening and re-connections all as required at site.
60Material and labour for Servicing of vaccum circuit breaker 11 KV. current cap 400/630/800 Amp by taking shut down and disconnecting electrical connections, making temporary electric supply restoration arrangement till servicing completed with reqd safety precautions complete removing of dust with blower, cleaning of all movable/ in-movable parts, checking all components, insulators/ studs with megger and replacing unserviceable parts, adjusting the male / female bushings in proper spacing, greasing all parts, tightening nuts and bolts, reconnecting all electrical connections, replacement of defective indicators lamp, any type testing, commissioning of VCB complete all as directed. Note: Major Spares replaced shall be measured and paid seperately. (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust, dirt & carbon deposits. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use electromechanical grease for the operating shaft, mating parts/contacts and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts.
61(vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish. (b) The following test shall be carried out:- (i) Wiring testing/ checking for any short (ii) Tripping coil resistance. (iii) IR Test with megger in open and closed condition. (iv) Closing coil resistance (c) Testing of following relays of control panelwith Injection Kit ,checking andprogramming of relay:- (i) Over current and earth fault relay (d) Testing of following Aux relay (i) DC Supply supervision relay. (ii) Master trip relay.
62Material and labour for vacuum interrupter/ Vacuum bottle suitable for 630/800 A VMX breaker complete all as specified and directed. Make : Crompton Greaves of any other make suitable/metching/equivlent to existing make
63Material and labour for Tripping coil 24 v DC, suitable for VCB complete all as specified and directed. Make : Crompton Greaves of any other make suitable/metching/equivlent to existing make
64Material and labour for Closing coil assy, 24 volt suitable for VCB complete all as specified and directed
65Material and labour for Power pack with battery backup suitable to work on 110 volts supply complete all as specified and directed
66Material and labour for Overcurrent & earth fault relay24 V operating voltage suitable for VCB 11 KV complete having suitable RS 485 port, incl necessary programming, connections and fixing arrangement and testing complete micom P111Schneider or equivalent all as specified and directed by Engineer-in-Charge.
67Material and labour for Hooter alarm/ Bell for fault indication for VCB Panel complete all as specified and directed
68Material and labour for Push button bracket assembly complete all as specified and directed.
69Material and labour for TNC Remote switch for automatic ON/ OFF for VCB from front panel complete all as specified and directed.
70Material and labour for replacement of Master trip relay 24V/110V/220V DC suitable for existing 11KV VCB complete all as specified and directed
71Material and labour for trivector meter suitable for 11KV/rt3/110V/rt3, class 0.5s, -/5A complete with necessary connections all as specified and directed.
72Material and labour for demand controller relay suitable for 11 KV VCB at complete with necessary wiring andsuitable CTs & necessary connections complete for tripping to control RMD as per CMD all as specified and directed. Make : L&T/Schneider/ABB/Siemens secure of other reputed make of approved by GE
73Material and labour for repair of RMU 11 KV 3/5 way any type & any make (Schneider, Siemens, Areva, Hartek or any other make) complete including removing/ disconnecting electric cable and earth connections from RMU, shifting the RMU from J loc through suitable transport to OEM/ authorized manufacturer/ service centre workshop at Chandigarh/ DElhi/ other suitable loc as approved by deptt and opening / step opening of RMU parts and diagnosing the fault complete including making necessary repairs, replacing complete defective AC & DC circuit control protection wiring, complete cleaning, servicing and replacing major defective parts and re-fixing, necessary repairs to gas chamber, vaccumizing and SF 6 gas filling, assembling and replacing parts for satisfactory functioning and shifting back to J1 loc Jalandhar cantt and installation, commissioning and making electrical connections complete all as directed. The major spares replaced shall be measured under relevant items of Sch.
74Material and labour for load break switch assy 12KV for RMU complete all as specified and directed
75Material and labour for annunciator window having 12 window LED display for alarm/ trip with soft push buttons (Reset, Ack, Mute, test) complete matching to existing suitable size with necessary fixing arrangements and connections complete all as specified and directed
76Material and labour for digital LED/ LCD display multifunction meter suitable to display kWh, PF , current , voltage parameters complete programmable type complete all as specified and directed.
77Material and labour for servicing of APFC panel 415 V upto 200 KVAR cap complete including checking electric connections, capacitance & functioning of indl capacitors and functioning of relay, necessary connections, replacement of unserviceable LED indicators complete all as specified and directed.
78Material and labour for Automatic power factor relay 8 steps with auto/manual operation , with built in metering option, suitable to be powered through AC 220 complete including necessary connections for satisfactory functioning of APFC panel complete all as specified and directed
79Material and labour for Auxiliary relay VAA type of make AREVA/ ALSTOM or equivalent makehaving 3 latch/ flag hand resetable type suitable to operate on 24 V DC complete matching to existing specs complete all as specified and directed.
80Material and labour for attending of complaint for VCB 11 KV for rectification of any type of fault in mechanisam, indication, protection, metering circuit, control circuit, operating mechanism or any other mechanism or circuit within 24 hrs of intimation to make VCB in fucntional state by Engineer-in-Charge complete. Note:- A recovery of Rs. 1000/- per hour will be levied in case no skilled technician attends complant within 24 hours of intimation.
81Servicing of ring main unit (RMU) 3/5 way 11 KV by taking shut down and disconnecting electrical connections, removing of dust with blower, cleaning of all movable/fixed parts, removing moisture/ hard carbon deposited due to flash over on bus bars and insulators with CRC/ Stanvac moisture/ carbon remover, checking all components, insulators/ studs, adjusting the male / female bushings in proper spacing, lubrication of moving parts, greasing all parts, tightening nuts and bolts, testing of CT & PT with suitable kit and reconnecting of all electrical connections, testing of RMU for healthiness and proper functioning and submitting report complete all as directed. Note: The Servicing/ testing shall be done by expert service engineer from manufacturer or channel partner or agency. Contractor shall submit complete report regarding CT & PT, Protection relay functioning pick up current & corresponding time value setting tests carried with testing kit. Any major Spare replaced shall be measured and paid separately
82Material and labour for removal of leakage from HT / LT bushing of Transformer 500 KVA complete by disconnecting electric connections, making temporary arrangement for cable connections to make elect supply functional, decanning reqd qty of oil, opening top cover and opening of rubber gaskets/ cork gasket, rubber seal and porcelain insulator of bushing rod and replacement of gasket complete for bush rod and assembling and making elect connections complete. Note: The replacement of gasket & seals of one bushing/ spindle rod shall be measured as one unit.
83Material and labour for insulation mat class "B" complying to IS 15652-2006of size 2.5 mm thicknessx1 Mtr width and 10 mtr length , working voltage 11KV complete all as specified and directed
84Material and labour for rubber mat of size 20 mm thickness, 2 Mtr length x 1 Mtr width as per IS 5424 complete all as specified and directed
85Material and labour fire extinguisher 9 kg Co2 type complete all as specified and directed
86Material and labour for painting (colour as directed) of GI/MS/ CI pipe of 50 mm bore dia including connected fittings and valves in the pipe line for water Treatment Plant / Sewage treatment plant or any other Loc by using mechanical means/ spray gun complete including scrapping of old paint with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint of colour code as per IS2379 including making arrow at spacing of 5 RM of size and colour as approved complete all as specified & directed by Engineer-in-Charge
87All as per Srl item No. 85.00 here-in-before but 80 mm bore dia
88All as per Srl item No. 85.00 here-in-before but 100 mm bore dia
89All as per Srl item No. 85.00 here-in-before but 150 mm bore dia
90All as per Srl item No. 85.00 here-in-before but 200mm bore dia
91Material and labour for scraping old paint from multi grade filter (MGF) dia 1600mm - 01 No, height 1500mm approx & softener having 1800mm dia - 01 No & height 2000mm of water Filtration plant including preparingsurface for painting, applying two coats of synthetic enamel paint in colour as approved by Deptt using spray gun complete all as specified & directed
92Material and labour for painting of Sewage Treatment Plant motor/pumps/ blowers as under mentioned of any sizes including scraping of old paint with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint by using spray gunapproved complete all as specified & directed by Engineer-in-Charge. (a) Air blower with motor-02 Nos (b) Sludge pump - 02 Nos (c) Filter press pump with motor -02 Nos (d) Filter pump-02 Nos (e) Presss filter-01 No (f) Irrigation pump- 02 Nos
93Material and labour for scraping old paint from MGF & ACF Filter - 01 No each at STP of sizes 1200 mm dia, height 1500mm approx with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint in steel grey by using spray gunapproved suitable paint by Engineer in Charge including writing in white/ black paint name of filter complete all as specified
94Supply and fixing in replacement DOL starter for submersible pump with 3 pole contactor, over load relay, start & stop push button & standard accessories of capacity 7.5 HP, 415 volts complete all as specified and directed.
95Material and labour for scraping old paint from fire hydrant of Height 2 mtr and GI Pipe at fire fighting plant with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint in steel grey by using spray gunapproved suitable paint by Engineer in Charge complete all as specified . (a) 200 mm dia -25 RM (b) 150 mm dia- 20 RM (c)Fire hydrant of height 2 mtr and 80 mm dia -09 Nos
96Supply and fixing in replacementsluice valve, flanged of class1.6 PN of size 100mm dia with cast iron wheel head complete all as specified
97Supply and fixing in replacement sluice valve, flanged of class1.6 PN of size 150mm diawith cast iron wheel head complete all as specified
98Supply and fixing in replacement sluice valve, flanged of class1.6 PN of size 200mm diawith cast iron wheel head complete all as specified
99Supply and fixing in replacement butterfly valve, of size 80mm dia complete all as specified & directed.
100Supply and fixing in replacement butterfly valve, of size 100 mm dia complete all as specified & directed.
101Supply and fixing in replacement Pressure gauge 4" dial 0 to 14 Kg/Sqcm ratingall specified and directed.
102Supply and fixing in replacement gun metal globe/gate valve with iron wheel head screwed both ends for iron pipe 40 mm bore complete all as specified and as directed by Engineer-in-Charge.
103All as per Srl item No. 101.00 here-in-before but 25 mm bore
104Material and labour for stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 50mm dia complete all as specified & directed.
105Supply and fixing GI tubing medium grade 50mm bore (in any length) with required fitting duly laid in trenches and connecting up with water supply mains including removing unserviceable tubing complete all as specified and directed
106All as per Srl item No. 104.00 here-in-before but GI pipe 80 mm bore
107All as per Srl item No. 104.00 here-in-before but GI pipe 40 mm bore
108All as per Srl item No. 104.00 here-in-before but GI pipe 15 mm bore
109All as per Srl item No. 104.00 here-in-before but GI pipe 25 mm bore
110Material and labour for opening of wash out sluice valve at any height of overhead tank ofany capacity & description drain out water and mud and closing the same after completion of work all as specified and directed. Note : Rate deemed to be included of all T&P required to execute the job
111Cleaning of 40000 gallon capacity underground sump at pump house No.1 and 2 by draining out water from the tank with portable pump sets, removing sludge, mud or any other foreign materials from the bottom andinternal surface and cleaningby wire brushing, washing internally by using bleaching powder and applying 2 coats of whitelime wash including re writing the date of cleaning, capacity of the tank etc with white paint on black back ground complete all as specified and as directed
112Cleaning of300000 litrs capacity underground sump at pump house no.1 and 2 by draining out water from the tank with portable pump sets, removing sludge, mud or any other foreign materials from the bottom andinternal surface and cleaningby wire brushing, washing internally by using bleaching powder and applying 2 coats of whitelime wash including re writing the date of cleaning, capacity of the tank etc with white flourscent white paint on black back ground complete all as specified and as directed
113Material and labour for taking up /taking out submersible pump & motor ofcapacity7.5HPfrom bore well by disconnecting electric connections of motor andusing tripod and chain pulley block, including unscrewing all column pipes of any size, any dia, any length and taking out keeping aside with nut, bolts for re-using complete all as specified and directed.Note:- Sr No. 110 & 111 The cleaning should be completed within minimum time without disturbing water supply schedule.The contractor shall quote his rate accordingly.
114Material and labour for lowering of submersible pump motor assay including making electric connections by making water proof joint and lowering it into bore well by using tripod and chain pulley block, including screwing all column pipes of any size, any dia, any length and tightening nut, bolts by using gaskets, testing before laying and complete testing after lowering complete all as specified and directed
115Material and labour and shifting, taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motorof same gauge and weight,including replacement of motor bush, thrust plate and reassembling the motor, well making it functional and testing complete all as specified.
116Material and labour for disconnectingsubmersible pump from electric motor of cap 7.5HP and taking to work shop for repair and replacementof unserviceable part such asgun metal bush, impeller and steel nuts & bolts of existing size and reassembling the pump with motor and making it functional, testing the pump to the entire satisfaction of Engineer-in-Charge
117Material and labour in repairs Mono block pump set 3of suitable HP with three phaseSquirrel cage Induction Motor (TEFC Type) in Rugged Cast iron construction Motor speed 2900, Discharge flow 501 - 1000 LPM approx, Discharge outlet size 25 - 50 mm approx, Head40 Mtr approxall as specified and directed
118Supply and fixing lowering PVC Insulated & PVC Sheathed Industrial 3 Core 4 sqmm Flat Submersible Cables with Copper Conductor for Submersible Pump Motor with Voltage Grade Grade 1100 Volts complete all as specified and directed by Engineer-in-Charge.
119Material and labour in repair of unserviceable Induction Electric Motor 3 phase 1 HP to 7.5 Hp complete including checking at site, opening connections, shifting to workshop for repair, opening, rewinding with suitable gauge copper wire, varnishing for proper functioning, shifting back and refixing, re-alinging in original position the same after winding for smooth operation of motor all as specified and directed.
120All as per Srl item No 118.00 here-in-before but for motor of cap 10 HP to 20 HP.
121Supply and fix in replacement MCBTPN 63 Amp all as specified and directed.
122S &F in repairs submersible motor pumping set suitable power/HP 415V,AC, 50 HZ, 3 pole suitable 200 mm dia bore Well, multistage delivery size 80 mm , discharge 630-270 LPM at 36-84 Mtr head complete all as specified and directed.
123Material and labour for water flow meter suitable having min flow capacity 25cum/hr with suitable flange ends complete with necessary fixing arrangements matching to WEN 65 model of Make ITRON or equivalent complete all as directed.
124Material and labour for repair of air blower 469 cum/hr cap at 5000mm WCof make Beta Maschinenfabrik complete included replacement of twin lobe rotor, supporting bearings and bush for twin lobe rotor, mechanical seal, gaskets complete for satisfactory functioning of blower complete all as directed.
125Material and labour for dewatering and de sludging dry or wetsludge with sewage by super sucker machine 18000 Ltr tank cap min & manual method or any other suitable arrangement by taking out manually/ transportation in suitable veh and depositing the same outside the MOD area to a distance 10km or as specified by Engineer-in-Charge complete for the UG Equalization sump of size 7.5mtr × 8m ×5m of STP
126All as per Srl item No. 124.00 here-in-before but oil and grease trap sizes 5.7mtr × 1.5m ×3m
127All as per Srl item No. 124.00 here-in-before but Sludge holding tank size5.0mtr × 3.0m ×4m
128All as per Srl item No. 124.00 here-in-before but Aeration tanks size 8.0mtr × 5.0m ×4m
129Material and labour for recharging of softener by provn ofwater softener salt (NaCl) tablet having min 99% purity complete by making liquid solution and recharging the resin as required at site as directed by Engineer-in-Charge. (Note: The weight of water softener tabet shall be measured as accounting unit for the purpose of payment)
130Material and labour for Effective microorganism (EM) solution Bioculture solution having shelf age minimum more than 6 months suitable for bacteria growth complete as required for STP plant as directed by Engineer-in-Charge
131Testing of water sample/ affluant water sample from NASL approved lab for testing of physical, chemical constitents/prameters incl collection of sample from site complete all as directed.
132Material and labour for change of fan belt for air blower No 2120 complete all as specified and directed.
133Material and labour for change of fan belt for Filter press No. A1350/A52 complete all as specified and directed.
134Material and labour for gear oil suitable for air blower required upto level complete all as specified and directed.
135Supply and usecalcium hypo-chlorite liquid based high strength chlorine granule (65% to 70%) suitable to water disinfection complete all as specified and directed.
136Material and labour for electromagnetic flow meter suitable to measure flow 650cum/ day minimumwith TEFLON lining, operating voltage 240 volts , IP-68with communication port complete with remote display with 7 mtrs length connecting wire suitable to be fixed on pipe size upto 80mm with all connecting flanges, rubber gasket , nuts & bolts complete all as specified and directed.
137Material and labour for scroll compressor 8.5 TR suitable for outdoor unit of ducted AC plant complete all as specified and directed.
138Material and labour for free chlorine testing kit suitable for min 50 test having suitable reagent,Orthotolidine / DPD with test tube, sample test tubes having various samples of different colour to distinguish free chlorine content complete all as specified and directed
139Material and labour for servicing of DG Sets 125 KVA/ 160 KVA make Cummins comprising of prime mover and alternator with accessories, control panel and connected electric circuits with various type of sensors etc complete by including checking of lubricating oil, coolant, filter, v-belt, self-starter, battery power, gauges and other connected accessories, cleaning of alternator with vaccum cleaner, fault finding and rectifying the fault by replacing the defective parts and identifying functioning of the DG Set (if any) of the following capacities complete all as specified and directed:- Notes:(a)Item comprises site visit charges for authorised technician of OEM of DG Set (or) qualified/experienced technician of DG Sets for checking, identifying the functionality of DG Set and will carry out required preventive maintenance work of DG Set and ensure smooth functioning of DG sets and connected works. (b)One service & minor maintenance with preventive maint of one DG set at one time shall be measured & paid as one unit (c)Major spares of DG Set will be measured and paid separately under relevant item of the CA catered as supply only. (d)Technician willcarry out the required checks as perrun hrs of DG set and based on time frequency for routine checkup/servicing on date fixed (or) as and when required or directed by Engineer-in-Charge (in case of breakdown of DG Set). (e)Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the job
140Supply for replacement of spin on fuel filter (pre and fine filter) element with O ring of make : Mico/Kirloskar/Ruston suitable for generator set of 125 to 160 KVA of make Cummins or equivalent complete all as specified and directed
141Supply and fixing of V-belt suitable for 125/160 KVA capacity DG set including removing old unserviceable fan belt all as specified and directed by Engr-in-charge.
142Supply only Air filter suitable for DG set 125 KVA make cummins complete all as specified and directed
143Supply and top up coolant oil complete all as specified and directed. Make : Volvo line / Servo / Castrol
144Supply and top up engine oil 15W40 grade complete all as specified and directed. Make : Volvo line / Servo / Castrol
145Supply and top up Battery Distilled water complete all as specified and directed
146Supply and fixing in repair heavy duty battery 12V, 180 AH, initial charging, filled with required electrolite/ distilled water and fixing/connecting with electric connector cable all as specified and directed. Make : Exide/ OKAYA/TATA or equivalent Luminous/Amaron
147Supply and fixing in replacement CT Coil with CT Ratio 250/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992 and as specified and directed.
148Supply and fixing in replacement On load change over switch 200 Amps, 4 pole, 415V, AC 50 Hz, front operated handle, totally enclosed in sheet metal enclosure including fixingon wall with suitable accessories and connecting the cable end with suitable size lugs, nuts/bolts/washers etc complete all as specified and directed.
149Material and labour for cleaning of fuel tank, removing sludge, dirt by draining fuel and cleaning with cotton waste complete all as required at site complete for 125 DG Set
150Dismantling, removing the self starter from the DG set of capacity DG 125KVA, opening the self starter body and overhauling/servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and directed.
151Supply and fixing (in repairs) voltage monitoring relay (VMR), existing model for AMF panels 415 volt, AC 50Hz all as specified and directed.
152Supply and fixing (in replacement) PVC insulated Single core, 35 sqmm, copper conductor, stranded cable suitable for inter connection of electric network inside panel including provn of suitable size copper thimbles/lugs with nuts, bolts & washers (considered 02 thimbles/lugs per RM) all as specified and directed.
153Material and labour in replacement Lub oil pressure gauge0 to 10 kg / sqcm complete all as specified and directed
154Attending complaints of fault in DG sets up to 160 KVA having any type of fault in control, protection circuit complete for fault tracing and rectification to make DG set functional . Complaint must beattend within3 hours after intimation to the contractor by the Department with qualified mechanic complete all as specified and directed. Notes : (i) If contractor fail to attend the complaint of DG set within 24 hours, recovery @ Rs. 500/- per hour shall be imposed upon the contractor. (ii) The spare parts shall be measured and paid separately under relevant items.
155Material and labour for power contactor MCX 33, 200 Amp,2 NO + 2 NC contacts 4 pole power contactor , with coil voltage 240/415 volt complete fixing and necessary connections arrangement complete all as specified and directed
156Material and labour for repair/overhauling of AMF panel for 125KVA DG set complete including fault diagnosing, removing burnt unserviceable wiring, replacement of complete control wiring for interlocking of contactors of mains, DG set for satisfactory functioning of AMF panel complete
Disclaimer :