| 1 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd35 mm2 3core |
| 2 | `RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked`4300 LPM x 25.00 m x 40.00 BHP |
| 3 | 1 HIGHWAY CROSSING FOR 300 MM I/D PIPE:-1.1. Boring /excavation including pit making at entry and exit point to the precise dimensions for the Launch of the specialized Auger boring machine in normal soil condition but not in Rock/Bolders/ any underground utility like foundation, water supply line coming in alignment or other underground obstructions complete in all respect including caution sign boards, signals, watching fencing, site clearance etc. For 500 mm i/dMS casing pipe. 1.2 Providing and insertion of 500 mm i/d M.S. Casing pipe 8 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following sizes including cutting, beveling, grinding, testingand radio graphically welding of pipe as per IS-1182 complete in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to R.D.S.O. as per specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion complete in all respect including cost and cartage of material to site of work as per drawing attached. 500 mm i/d MS casing pipe 1.3 Providing and insertion of 300 mm i/d M.S. carrier pipe 8 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following sizes including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 complete in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to R.D.S.O. as per specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion complete in all respect including cost and cartage of material to site of work as per drawing attached. 300 mm i/d MS casing pipe 1.5 Providing concrete block 1:1-1/2:3 on both ends to plug the space between casing and carrier pipe including all material and labour complete in all respect to the entire satisfaction of Engineer in charge1.6 Provision for probe radar survey to check any underground obstruction before finalizing the alignment. |
| 4 | FHTC: Making functional househlod tap connections including dismentling and restoration of existing CC/IPB Road / street, digging suitable size pit, trench for connecting line. Supply, erection and commossioning of 10 mm i/d brass / Gun metal ferrule, 3.00 m long IS marked 15 mm i/d G.i pipe class B including all fittings as per specifications and entire satisfaction of Engineer-in-charge complete in all respect. |
| 5 | Providing and fixing of 15 mm nominal diameter water meter as per IS 779:1994 Inferential type dry dial, mechanical driven, non megnatic drive, straight reading cyclometer type, 7-inline consequent digits with one centre point for easy reading complete in all respect. |
| 6 | WTP: Design, construction of automated PLC controlled of 4.00 MLD water treatment plant based on rapid sand filtration technology, including interconnecting DI pipe from raw water pump to inlet box of WTP, CWT and suction well for CW, inlet channel, Alum dozing, flash mixing, Clari floculator, filter box, over head Reservoir for back wash including pump sets and electric control panel, waste water tank including pump sets and electric control panel , DI pipes, DI Specials, manholes covers, air scour equipment, chemical house with chlorination equipments, all other civil, mechanical, electric installations complete in all respects as per specifications (make of Sluice valves / NRV: IVC / VAG / Kirlosker)and all other works contingent thereto complete in all respects.Including Operation and Maintenance of new WTP for a period 3 months during trial run, 12 months during defect liability period after successful trial run periodand 5 years thereafter on the commissioning of new WTP.(The rate quoted by contractor shall be bifurcated into capital cost (as 80%) and OandM cost (as 20%) of quoted L.S cost) |
| 7 | Supplying, erection, testing and commissioning Variable frequency drive for 20 HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge. VFD Enclosure with approximate dimension of 480mm X 300mm X 260mm with 3C3 Coated PCB as per IEC Standard 61721-3-3 and designed at 50 degree Celcius temperature to work without any derating with Digital Graphical Display meter for Current , Voltage , KW , RPM and Frequency and having Modbus communication port for IoT Connectivity.Panel with Automatic Energy Optimisation feature with inbuilt Capacitors to ensure Power Factor )0.98 having Six number programmable Digital inputs relay, Two number analog input relay , two number programmable Pulse Input relay and One Number Programmable Analog Output Relay |
| 8 | Supplying, erection, testing and commissioning Variable frequency drive for 125 HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge. VFD Enclosure with approximate dimension of 770mm X 400mm X 335mm with 3C3 Coated PCB as per IEC Standard 61721-3-3 and designed at 50 degree Celcius temperature to work without any derating with Digital Graphical Display meter for Current , Voltage , KW , RPM and Frequency and having Modbus communication port for IoT Connectivity.Panel with Automatic Energy Optimisation feature with inbuilt Capacitors to ensure Power Factor )0.98 having Six number programmable Digital inputs relay , Two number analog input relay , two number programmable Pulse Input relay and One Number Programmable Analog Output Relay |
| 9 | Supplying, erection, testing and commissioning Variable frequency drive for 40 HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge. VFD Enclosure with approximate dimension of 650mm X 300mm X 260mm with 3C3 Coated PCB as per IEC Standard 61721-3-3 and designed at 50 degree Celcius temperature to work without any derating with Digital Graphical Display meter for Current , Voltage , KW , RPM and Frequency and having Modbus communication port for IoT Connectivity.Panel with Automatic Energy Optimisation feature with inbuilt Capacitors to ensure Power Factor )0.98 having Six number programmable Digital inputs relay , Two number analog input relay , two number programmable Pulse Input relay and One Number Programmable Analog Output Relay |