Tender For Annual Rate Contract 2024 25 For Replacement Of Parts Repair Maintenance Of Horizontal Centrifugal Pumps, Submersible Pumps Of Different Capacitie Swithallied Works Installed At Various Pumping Stations Under Jals Hakti Phe Division Poonch, poonch-Jammu And Kashmir

Public Health Engineering Department-PHED has published Tender For Annual Rate Contract 2024 25 For Replacement Of Parts Repair Maintenance Of Horizontal Centrifugal Pumps, Submersible Pumps Of Different Capacitie Swithallied Works Installed At Various Pumping Stations Under Jals Hakti Phe Division Poonch. Submission Date for this Tender is 27-03-2024. Submersible Pump Tenders in poonch Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42901292
Tender For Annual Rate Contract 2024 25 For Replacement Of Parts Repair Maintenance Of Horizontal Centrifugal Pumps, Submersible Pumps Of Different Capacitie Swithallied Works Installed At Various Pumping Stations Under Jals Hakti Phe Division Poonch
Open Tender
Indian
Jammu And Kashmir
poonch
27-03-2024

Tender Details

Annual Rate Contract 2024 25 For Replacement Of Parts Repair Maintenance Of Horizontal Centrifugal pumps, Submersible Pumps Of Different Capacitie Swithallied Works Installed At Various Pumping Stations Under Jals Hakti Phe Division Poonch. , Disconnection Of Incoming Power Connection From Main Switch /Mccb/Voltage Stabilizer And Checking Of Fault , Making Of Temporary Arrangement For Running Of Pumping Machinery , Replacement Of Damaged Mnx 25 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 25 , Replacement Of Damaged Mnx 45 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 40 , Replacement Of Damaged Mnx 50 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 50 , Replacement Of Damaged Mnx 70 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 70 , Replacement Of Damaged Mnx 80 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 80 , Replacement Of Damaged Mnx 95 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 95 , Replacement Of Damaged Mnx 110 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 110 , Replacement Of Damaged Mnx 140 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 185 , Replacement Of Damaged Mnx 185 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 185 , Replacement Of Damaged Mnx 225 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 225 , Replacement Of Damaged Mnx 250 By Way Of Providing /Fitting Of 3 Pole Power Contractor- Mnx 250 , Replacement Of Damaged Kit Of Mnx 25 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 45 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 50 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 70 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 80 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 95 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 110 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 140 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 185 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 225 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 250 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 45 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 50 By Way Of Providing /Fitting Of New Kit , Replacement Of Damaged Coil Of Mnx 70 By Way Of Providing /Fitting Of Coil , Replacement Of Damaged Coil Of Mnx 80 By Way Of Providing /Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 95 By Way Of Providing /Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 110 By Way Of Providing /Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 140 By Way Of Providing /Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 185 By Way Of Providing /Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 225 By Way Of Providing /Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 250 By Way Of Providing /Fitting Of New Coil , Replacement Of Damaged Mpr , Replacement Of Damaged Over Load Relay & P/F New Overload Relay , Replacement Of Damaged Under Load Relay & P/F New Underload Relay , Replacement Of Single Phase Relay & P/Fsingle Phase Relay , Replacement Of Reverse Phase Relay & P/Freverse Phase Relay , Replacement Of Damaged Mccb 100 By Way Of Providing /Fitting Ofmccb 100 Amp , Replacement Of Damaged Mccb 125 By Way Of Providing /Fitting Ofmccb 125 Amp , Replacement Of Damaged Mccb 200 By Way Of Providing /Fitting Ofmccb 200 Amp , Replacement Of Damaged Mccb 250 By Way Of Providing /Fitting Ofmccb 250 Amp , Replacement Of Damaged Mccb 400 By Way Of Providing /Fitting Ofmccb 400 Amp , Replacement Of Damaged Mccb 600 By Way Of Providing /Fitting Ofmccb 600 Amp , Replacement Of Damaged Mccb 100 By Way Of Providing /Fitting Ofmccb 100 Amp , Making Ofincoming Power Connection To Main Switch /Mccb/Voltage Stabilizer And Checking On Full Load. , Upto 100 Amp , Charges For Minor Repair/Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc , Providing /Fitting Ofcircuit Wiring , Providing /Fitting Ofvoltmeter , Providing /Fitting Of Ampmeter , Providing /Fitting Ofamp Selector Switch , Providing /Fitting Ofvolt Selector Switch , Providing /Fitting Ofpush Button , Providing /Fitting Ofindicator Lamps , Providing /Fitting Ofstar Delta Timer , Providing /Fitting Ofterminal Plate , Providing /Fitting Offault Analyzer , Providing /Fitting Ofquartz Timer , Providing /Fitting Ofdelay Timer , Providing /Fitting Ofpower Wiring , Providing /Fitting Ofthermal Overload Relay , Providing /Fitting Ofbus Bar , Providing /Fitting Ofboiled Fuse Link , Providing /Fitting Offuse Holder Suitable For Bolted Fuse Link , Making Ofincoming Power Connection To Main Switch /Mccb/Voltage Stabilizer And Checking On Full Load. , 125 Amp. To 200 Amp , Charges For Minor Repair/Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc , Providing /Fitting Ofcircuit Wiring , Providing /Fitting Ofvoltmeter , Providing /Fitting Of Ampmeter , Providing /Fitting Ofamp Selector Switch , Providing /Fitting Ofvolt Selector Switch , Providing /Fitting Ofindicator Lamps , Providing /Fitting Ofpush Button , Providing /Fitting Ofstar Delta Timer , Providing /Fitting Ofterminal Plate , Providing /Fitting Offault Analyzer , Providing /Fitting Of Quartz Timer , Providing /Fitting Ofdelay Timer , Providing /Fitting Ofpower Wiring , Providing /Fitting Ofthermal Overload Relay , Providing /Fitting Ofbus Bar , Providing /Fitting Ofboiled Fuse Link , Providing /Fitting Offuse Holder Suitable For Bolted Fuse Link , Making Ofincoming Power Connection To Main Switch /Mccb/Voltage Stabilizer And Checking On Full Load. , 225 Amp. To 300 Amp. , Charges For Minor Repair/Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc , Providing /Fitting Ofcircuit Wiring , Providing /Fitting Ofvoltmeter , Providing /Fitting Of Ampmeter , Providing /Fitting Ofamp Selector Switch , Providing /Fitting Ofvolt Selector Switch , Providing /Fitting Ofindicator Lamps , Providing /Fitting Ofpush Button , Providing /Fitting Ofstar Delta Timer , Providing /Fitting Ofterminal Plate , Providing /Fitting Offault Analyzer , Providing /Fitting Ofquartz Timer , Providing /Fitting Ofdelay Timer , Providing /Fitting Ofpower Wiring , Providing /Fitting Ofthermal Overload Relay , Providing /Fitting Ofbus Bar , Providing /Fitting Ofboiled Fuse Link , Providing /Fitting Offuse Holder Suitable For Bolted Fuse Link , Making Ofincoming Power Connection To Main Switch /Mccb/Voltage Stabilizer And Checking On Full Load. , 63 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch100 Ampere , Providing & Fitting Of Mccb 100 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , 100 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch250 Ampere , Providing & Fitting Of Mccb 250 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , 150 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch250 Ampere , Providing & Fitting Of Mccb 250 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , 200 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch400 Ampere , Providing & Fitting Of Mccb 400 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , 250 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch400 Ampere , Providing & Fitting Of Mccb 400 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , Oil Immersed Start Delta Starter , Repair Of Star Delta Oil Immersed Starter Upto 20Hp Capacity By Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 30Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 40Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 50Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 60Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 70Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 80Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 100Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 125Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 125-150Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Providing And Laying Of Earthing Of Electro Mechanical Machinery (Transformer/Motors/Lt Panels/Voltage Stablizer) , Carriage/Shifting Of 100 Kva Voltage Stabilzer From Pump Room On Head Load To And Fro Up To Stacking Place On Road Side With Loading/Unloading Charges , Carriage/Shifting Of 63 Kva Voltage Stabilzer From Pump Room On Head Load To And Fro Up To Stacking Place On Road Side With Loading/Unloading Charges , Carriage/Shifting Of 50 Kva Voltage Stabilzer From Pump Room On Head Load To And Fro Up To Stacking Place On Road Side With Loading/Unloading Charges , Carriage/Shifting Of 200/250 Kva Voltage Stabilzer From Pump Room On Head Load To And Fro Up To Stacking Place On Road Side With Loading/Unloading Charges

Key Value

Document Fees
INR 1000 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:- Annual Rate Contract for repairs of LT Control panels, Voltage Stabilizers and Starters of various capacities by way of replacement of components with allied works installed at various pumping stations under Jal Shakti (PHE) Division Poonch.
Sl. No. Item Description
1Disconnection of incoming Power connection from main switch /MCCB/Voltage Stabilizer and checking of fault
2Making of temporary arrangement for running of pumping machinery
3Replacement of Damaged MNX 25 by way of Providing /fitting of 3 pole power contractor- MNX 25
4Replacement of Damaged MNX 45 by way of Providing /fitting of 3 pole power contractor- MNX 40
5Replacement of Damaged MNX 50 by way of Providing /fitting of 3 pole power contractor- MNX 50
6Replacement of Damaged MNX 70 by way of Providing /fitting of 3 pole power contractor- MNX 70
7Replacement of Damaged MNX 80 by way of Providing /fitting of 3 pole power contractor- MNX 80
8Replacement of Damaged MNX 95 by way of Providing /fitting of 3 pole power contractor- MNX 95
9Replacement of Damaged MNX 110 by way of Providing /fitting of 3 pole power contractor- MNX 110
10Replacement of Damaged MNX 140 by way of Providing /fitting of 3 pole power contractor- MNX 185
11Replacement of Damaged MNX 185 by way of Providing /fitting of 3 pole power contractor- MNX 185
12Replacement of Damaged MNX 225 by way of Providing /fitting of 3 pole power contractor- MNX 225
13Replacement of Damaged MNX 250 by way of Providing /fitting of 3 pole power contractor- MNX 250
14Replacement of Damaged Kit of MNX 25 by way of Providing /fitting of new kit
15Replacement of Damaged Kit of MNX 45 by way of Providing /fitting of new kit
16Replacement of Damaged Kit of MNX 50 by way of Providing /fitting of new kit
17Replacement of Damaged Kit of MNX 70 by way of Providing /fitting of new kit
18Replacement of Damaged Kit of MNX 80 by way of Providing /fitting of new kit
19Replacement of Damaged Kit of MNX 95 by way of Providing /fitting of new kit
20Replacement of Damaged Kit of MNX 110 by way of Providing /fitting of new kit
21Replacement of Damaged Kit of MNX 140 by way of Providing /fitting of new kit
22Replacement of Damaged Kit of MNX 185 by way of Providing /fitting of new kit
23Replacement of Damaged Kit of MNX 225 by way of Providing /fitting of new kit
24Replacement of Damaged Kit of MNX 250 by way of Providing /fitting of new kit
25Replacement of Damaged Kit of MNX 45 by way of Providing /fitting of new kit
26Replacement of Damaged Kit of MNX 50 by way of Providing /fitting of new kit
27Replacement of Damaged coil of MNX 70 by way of Providing /fitting of coil
28Replacement of Damaged coil of MNX 80 by way of Providing /fitting of new coil
29Replacement of Damaged coil of MNX 95 by way of Providing /fitting of new coil
30Replacement of Damaged coil of MNX 110 by way of Providing /fitting of new coil
31Replacement of Damaged coil of MNX 140 by way of Providing /fitting of new coil
32Replacement of Damaged coil of MNX 185 by way of Providing /fitting of new coil
33Replacement of Damaged coil of MNX 225 by way of Providing /fitting of new coil
34Replacement of Damaged coil of MNX 250 by way of Providing /fitting of new coil
35Replacement of Damaged MPR
36Replacement of damaged over load relay & P/F new overload relay
37Replacement of damaged under load relay & P/F new underload relay
38Replacement of single phase relay & P/Fsingle phase relay
39Replacement of reverse phase relay & P/Freverse phase relay
40Replacement of Damaged MCCB 100 by way of Providing /fitting ofMCCB 100 Amp
41Replacement of Damaged MCCB 125 by way of Providing /fitting ofMCCB 125 Amp
42Replacement of Damaged MCCB 200 by way of Providing /fitting ofMCCB 200 Amp
43Replacement of Damaged MCCB 250 by way of Providing /fitting ofMCCB 250 Amp
44Replacement of Damaged MCCB 400 by way of Providing /fitting ofMCCB 400 Amp
45Replacement of Damaged MCCB 600 by way of Providing /fitting ofMCCB 600 Amp
46Replacement of Damaged MCCB 100 by way of Providing /fitting ofMCCB 100 Amp
47Making ofincoming Power connection to main switch /MCCB/Voltage Stabilizer and checking on full load.
48Upto 100 Amp
49Charges for minor repair/servicing of LT Control Panel including minor parts like meters, indicators , timers etc
50Providing /fitting ofcircuit wiring
51Providing /fitting ofvoltmeter
52Providing /fitting of ampmeter
53Providing /fitting ofAmp selector switch
54Providing /fitting ofvolt selector switch
55Providing /fitting ofPush Button
56Providing /fitting ofindicator lamps
57Providing /fitting ofstar delta timer
58Providing /fitting ofterminal plate
59Providing /fitting offault analyzer
60Providing /fitting ofquartz timer
61Providing /fitting ofdelay timer
62Providing /fitting ofpower wiring
63Providing /fitting ofthermal overload relay
64Providing /fitting ofbus bar
65Providing /fitting ofboiled fuse link
66Providing /fitting offuse holder suitable for bolted fuse link
67Making ofincoming Power connection to main switch /MCCB/Voltage Stabilizer and checking on full load.
68125 Amp. To 200 amp
69Charges for minor repair/servicing of LT Control Panel including minor parts like meters, indicators , timers etc
70Providing /fitting ofcircuit wiring
71Providing /fitting ofvoltmeter
72Providing /fitting of ampmeter
73Providing /fitting ofAmp selector switch
74Providing /fitting ofvolt selector switch
75Providing /fitting ofindicator lamps
76Providing /fitting ofPush Button
77Providing /fitting ofstar delta timer
78Providing /fitting ofterminal plate
79Providing /fitting offault analyzer
80Providing /fitting of quartz timer
81Providing /fitting ofdelay timer
82Providing /fitting ofpower wiring
83Providing /fitting ofthermal overload relay
84Providing /fitting ofbus bar
85Providing /fitting ofboiled fuse link
86Providing /fitting offuse holder suitable for bolted fuse link
87Making ofincoming Power connection to main switch /MCCB/Voltage Stabilizer and checking on full load.
88225 Amp. To 300 Amp.
89Charges for minor repair/servicing of LT Control Panel including minor parts like meters, indicators , timers etc
90Providing /fitting ofcircuit wiring
91Providing /fitting ofvoltmeter
92Providing /fitting of ampmeter
93Providing /fitting ofAmp selector switch
94Providing /fitting ofvolt selector switch
95Providing /fitting ofindicator lamps
96Providing /fitting ofPush Button
97Providing /fitting ofstar delta timer
98Providing /fitting ofterminal plate
99Providing /fitting offault analyzer
100Providing /fitting ofquartz timer
101Providing /fitting ofdelay timer
102Providing /fitting ofpower wiring
103Providing /fitting ofthermal overload relay
104Providing /fitting ofbus bar
105Providing /fitting ofboiled fuse link
106Providing /fitting offuse holder suitable for bolted fuse link
107Making ofincoming Power connection to main switch /MCCB/Voltage Stabilizer and checking on full load.
10863 KVA Voltage Stablizer
109Rewinding of copper Coil
110Providing & Fitting of Rotary Switch as per size
111Providing & Fitting of Change Over Switch100 ampere
112Providing & Fitting of MCCB 100 ampere
113Providing & Fitting of Indicator
114Providing & Fitting of Selector Switch
115Providing & Fitting of Amperemeter
116Providing & Fitting of Voltmeter
117Fresh Transformer Oil per litre
118Providing & Fitting of Nut Bolts
119Wiring Complete job with insultor
120Rate of Old Transformer Oil per kg
121Disconnecting of power connection of the Voltage Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour.
122Assembling of stabilizer, connecting the power connections and testing on load.
123100 KVA Voltage Stablizer
124Rewinding of copper Coil
125Providing & Fitting of Rotary Switch as per size
126Providing & Fitting of Change Over Switch250 ampere
127Providing & Fitting of MCCB 250 ampere
128Providing & Fitting of Indicator
129Providing & Fitting of Selector Switch
130Providing & Fitting of Amperemeter
131Providing & Fitting of Voltmeter
132Fresh Transformer Oil per litre
133Providing & Fitting of Nut Bolts
134Wiring Complete job with insultor
135Rate of Old Transformer Oil per kg
136Disconnecting of power connection of the Voltage Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour.
137Assembling of stabilizer, connecting the power connections and testing on load.
138150 KVA Voltage Stablizer
139Rewinding of copper Coil
140Providing & Fitting of Rotary Switch as per size
141Providing & Fitting of Change Over Switch250 ampere
142Providing & Fitting of MCCB 250 ampere
143Providing & Fitting of Indicator
144Providing & Fitting of Selector Switch
145Providing & Fitting of Amperemeter
146Providing & Fitting of Voltmeter
147Fresh Transformer Oil per litre
148Providing & Fitting of Nut Bolts
149Wiring Complete job with insultor
150Rate of Old Transformer Oil per kg
151Disconnecting of power connection of the Voltage Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour.
152Assembling of stabilizer, connecting the power connections and testing on load.
153200 KVA Voltage Stablizer
154Rewinding of copper Coil
155Providing & Fitting of Rotary Switch as per size
156Providing & Fitting of Change Over Switch400 ampere
157Providing & Fitting of MCCB 400 ampere
158Providing & Fitting of Indicator
159Providing & Fitting of Selector Switch
160Providing & Fitting of Amperemeter
161Providing & Fitting of Voltmeter
162Fresh Transformer Oil per litre
163Providing & Fitting of Nut Bolts
164Wiring Complete job with insultor
165Rate of Old Transformer Oil per kg
166Disconnecting of power connection of the Voltage Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour.
167Assembling of stabilizer, connecting the power connections and testing on load.
168250 KVA Voltage Stablizer
169Rewinding of copper Coil
170Providing & Fitting of Rotary Switch as per size
171Providing & Fitting of Change Over Switch400 ampere
172Providing & Fitting of MCCB 400 ampere
173Providing & Fitting of Indicator
174Providing & Fitting of Selector Switch
175Providing & Fitting of Amperemeter
176Providing & Fitting of Voltmeter
177Fresh Transformer Oil per litre
178Providing & Fitting of Nut Bolts
179Wiring Complete job with insultor
180Rate of Old Transformer Oil per kg
181Disconnecting of power connection of the Voltage Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour.
182Assembling of stabilizer, connecting the power connections and testing on load.
183Oil Immersed Start Delta Starter
184Repair of Star Delta Oil Immersed starter upto 20HP Capacity by way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
185Repair of Star Delta Oil Immersed starter upto 30HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
186Repair of Star Delta Oil Immersed starter upto 40HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
187Repair of Star Delta Oil Immersed starter upto 50HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
188Repair of Star Delta Oil Immersed starter upto 60HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
189Repair of Star Delta Oil Immersed starter upto 70HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
190Repair of Star Delta Oil Immersed starter upto 80HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
191Repair of Star Delta Oil Immersed starter upto 100HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
192Repair of Star Delta Oil Immersed starter upto 125HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
193Repair of Star Delta Oil Immersed starter upto 125-150HP Capacityby way of replacement of damaged contact points, no load coil, contact point holders , replacement of T oil and testing.
194Providing and laying of Earthing of Electro Mechanical Machinery (Transformer/motors/LT Panels/Voltage Stablizer)
195Carriage/Shifting of 100 KVA Voltage Stabilzer from pump room on head load to and fro up to stacking place on road side with loading/unloading charges
196Carriage/Shifting of 63 KVA Voltage Stabilzer from pump room on head load to and fro up to stacking place on road side with loading/unloading charges
197Carriage/Shifting of 50 KVA Voltage Stabilzer from pump room on head load to and fro up to stacking place on road side with loading/unloading charges
198Carriage/Shifting of 200/250 KVA Voltage Stabilzer from pump room on head load to and fro up to stacking place on road side with loading/unloading charges
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail