Tender For Increasing Capacity Of 33 / 11 Kv Sub Station Degree College From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli And Increasing Capacity Of 33 / 11 Kv S / S Bilarideeh From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli On Semi Turnkey Ba, chandauli-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Tender For Increasing Capacity Of 33 / 11 Kv Sub Station Degree College From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli And Increasing Capacity Of 33 / 11 Kv S / S Bilarideeh From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli On Semi Turnkey Ba. Submission Date for this Tender is 30-03-2024. Electrification Work Tenders in chandauli Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42887395
Tender For Increasing Capacity Of 33 / 11 Kv Sub Station Degree College From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli And Increasing Capacity Of 33 / 11 Kv S / S Bilarideeh From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli On Semi Turnkey Ba
Open Tender
Indian
Uttar Pradesh
chandauli
30-03-2024

Tender Details

Increasing Capacity Of 33 / 11 Kv Sub Station Degree College From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli And Increasing Capacity Of 33 / 11 Kv S / S Bilarideeh From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli On Semi Turnkey Basis.. ( All Material Should Be As Approved Gtp By Puvvnl ( Standard Make ) .-2 Separate Earthing Of T / F ( 2X60fit ) 3 Alluminium Lug 300Sqmm 4 Erection Ofincreasing Capacity Of 33 / 11 Kv S / S Degree College From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli 5 Acsr Dog Conductor 6 M.S Angle 65X65x6mm ( For Cable Stand & Neutral Earthing ) 7 Separate Earthing Of T / F ( 2X60fit ) 8 Alluminium Lug 300Sqmm 9 Laying & Dressing Of 11 Kv 3X300sqmm Xlpe Cable After Digging &Making Of Cable Trench Including Loop ( Sand, Bricks & Stone Slab Will Be Provided By Contractor ) 10 Making Of 11 Kv 3X300sqmm Indoor / Outdoor Jointing Kit 11 Repairing Of T / F & Vcb Plinth 12 Dismantling Of Old & Used 33 / 11Kv, 05Mva Power T / F By Disconnection Of Radiator, Conservator & Other Accessories After Removal Of T / F Oil 13 Shifting Of Old & Used 33 / 11Kv, 05Mva Power T / F From Existing Transformer Plinth To Safe Place In Switchyard 14 Erection Of New 33 / 11Kv, 10 Mva Power T / F Including Shifting Of T / F From Outside To Inside The Switchyard & Mounting On T / F Plinth In Safe Position Thereafter Fixing & Commissioning Of All Accessories Like Radiator, Conservator Etc. Top Up Of T / F Oil. 15 Sundry Civil Work ( Leveling Of Switchyard To Solve Water Logging And Laying Of Brick In Switchyard Complete ) 16 Cartage Of All Other Material Charges 17 Supply For Increasing Capacity Of 33 / 11 Kv S / S Bilarideeh From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli 18 Separate Earthing Of T / F ( 2X60fit ) 19 Top Channel Clamp 20 Dropper Angle Clamp 21 Bracing Angle Clamp 22 Cable Holding Clamp 23 Pg Clamp For Dog Conductor 24 Alluminium Lug 300Sqmm 25 G.I Pipe 150Mm Dia 26 Erection Of Increasing Capacity Of 33 / 11 Kv S / S Bilarideeh From ( 1X5 Mva ) To ( 1X10 Mva ) , Dist- Chandauli 27 11 Kv Outgoing Switchgear 200 / 100 / 5A, 350Mva 28 Pcc Pole 8.5Mtr 29 Ms Top Channel 100X50x6mm-2240Mm 30 Ms Dropper Angle 50X50x6-2028 Mm 31 Ms Angle Iron 65X65x6mm-2700Mm Long Bracing With 4 Clamp 32 11 Kv Disc Insulator Polymer Type 45 Kn 33 11 Kv Disc Fitting 45Kn 34 11 Kv Pin Insulator Polymer Type 35 Ms Earthing Rod 20X2500 Mm And 6 Swg Earthing Wire Etc. 36 Complete Stay ( Gi Stay Rod 20X1800mm, Stay Wire 7 / 8Swg 10Kg, Stay Clamp, Bolt, Nut &Washer With Concrete Grouting ) 37 Acsr Dog Conductor 38 M.S Angle 65X65x6mm ( For Cable Stand & Neutral Earthing ) 39 Separate Earthing Of T / F ( 2X60fit ) 40 Top Channel Clamp 41 Dropper Angle Clamp 42 Bracing Angle Clamp 43 Cable Holding Clamp 44 Pg Clamp For Dog Conductor 45 Alluminium Lug 300Sqmm 46 G.I Pipe 150Mm Dia 47 Grouting, Concreting & Plinthing Of Pcc 48 Laying & Dressing Of 11 Kv 3X300sqmm Xlpe Cable After Digging &Making Of Cable Trench Including Loop ( Sand, Bricks & Stone Slab Will Be Provided By Contractor ) 49 Laying & Dressing Of 11 Kv 3X185sqmm Xlpe Cable After Digging &Making Of Cable Trench Including Loop ( Sand, Bricks & Stone Slab Will Be Provided By Contractor ) 50 Making Of 11 Kv 3X300sqmm Indoor / Outdoor Jointing Kit 51 Making Of 11 Kv 3X185sqmm Indoor / Outdoor Jointing Kit 52 Repairing Of T / F & Vcb Plinth 53 Dismantling Of Old & Used 33 / 11Kv, 05Mva Power T / F By Disconnection Of Radiator, Conservator & Other Accessories After Removal Of T / F Oil 54 Shifting Of Old & Used 33 / 11Kv, 05Mva Power T / F From Existing Transformer Plinth To Safe Place In Switchyard 55 Erection Of New 33 / 11Kv, 10 Mva Power T / F Including Shifting Of T / F From Outside To Inside The Switchyard & Mounting On T / F Plinth In Safe Position Thereafter Fixing & Commissioning Of All Accessories Like Radiator, Conservator Etc. Top Up Of T / F Oil. 56 Sundry Civil Work ( Leveling Of Switchyard To Solve Water Logging And Laying Of Brick In Switchyard Complete ) And ( Repair Of Boundary Wall, Gate Etc ) If Required During Erection Of Power Transformer ) 57 Cartage Of All Other Material Charges

Key Value

Document Fees
INR 3540 /-
EMD
INR 10500.0 /-
Tender Value
Refer document