Tender For Redevelopment And Remodeling Of Existing Building Adjoining To Vice Regal Lodge, University Of Delhi. (Electrical Work And Air Conditioning Work)., Delhi-Delhi

Delhi University has published Tender For Redevelopment And Remodeling Of Existing Building Adjoining To Vice Regal Lodge, University Of Delhi. (Electrical Work And Air Conditioning Work).. Submission Date for this Tender is 27-03-2024. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42882873
Tender For Redevelopment And Remodeling Of Existing Building Adjoining To Vice Regal Lodge, University Of Delhi. (Electrical Work And Air Conditioning Work).
Open Tender
Indian
Delhi
Delhi
27-03-2024

Tender Details

Redevelopment And Remodeling Of Existing Building Adjoining To Vice Regal Lodge, University Of Delhi. ( Electrical Work And Air Conditioning Work ) .

Key Value

Document Fees
INR 1000 /-
EMD
INR 283368.0 /-
Tender Value
INR 1.41 Crore /-

BOQ Items

Name of Work:Redevelopment and remodeling of existing building adjoining to Vice Regal Lodge, University of Delhi. (Electrical work+ Air Conditioning work).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
2Supplying and fixingstepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
3S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc. as reqd.
46 Module
512 Module
6Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
73 x 2.5 sq.mm
83 x 4 sq.mm
93 x 6 sq.mm
10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x 10 + 2 x 6 sqmm
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1215/16 amps switch
136 pin 15/16 amps socket outlet
145/6 amps switch
153 pin 5/6 amps socket outlet
16Telephone socket outlet
17Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required.
18Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Moter, Class of Insulation: B, 3 Nos. Blades, 30 cm long down rod, 2 nos. conopies, shackle kit, safety rope, copper winding, power Factor not less than 0.9, service Value (CMM/W) minimum 6.85, Air Delivery minimum 215 CMM, 350 RPM (Tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temprature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC supply, earthing etc. complete as required
19Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
20Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
21Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
22Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amp
23Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2425 mm
2520 mm
26Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
27Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
28Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
29S/F/testing and commissioning of LED fitting single box type fitting ( 1x 18 watts ) 40000 burning hour complete with all accessories having 1 no. 18 watt MAS LEDtubes etc. on directly on ceiling or wall i/c connection with 1.5 sqmm FR PVC copper cond. cable etc. as reqd.( Model no. TMC 502 1 x T LED 22WP3242 ) ( Philips/Trilux )
30S/F/testing and commissioning of LED fitting double box type fitting ( 2 x 18 watts )complete with all accessories having 2 nos Mas LED 18 watt tubes etc. on directly on ceiling or wall i/c connection with 1.5 sqmm FR PVC copper cond. cable etc. as reqd.( Model no. TMC 502 2 x T LED 22WP3242 ) ( Philips/Trilux )
31S/F 1 Nos. RJ-45, 1 Module box i/c modular platecovering in front on surface connection etc. as required.
32S/F DLP UPVC trunking compartmentwith cover clip on separates partition left right topinternalangle, flat angle, raise function,flat function cover to body joints mosaic clip & support from mosaicisolation bracket 2 mm thick plastic.(Legrand) 105 mm x 50 mm with all accessories.
33P/Finstallation,testing and commissioing of following MCCB AC supply complete with connection in the suitable enclosure etc as reqd. at site .
34250 amps 35 KA MCCB (Model No. DN3-200N) (L & T)
35400 amps 35 KA MCCB (Model No. DN3-400N) (L & T)
36Servicing/cleaning/meggering/checking of load balancing /checking with ton tester of esixting panel i/c removing the dust and carbonized and dress up the hanging wire along with thimble if necessary etc as reqd. at site.
37Supplying/installation/testing and commissioning of2" x 2" LEDrecessed ceiling/surface fitting 42 watt240 volt50 HZ and 6500 K42000 lumens and full glow G6 with a long servies including making connection etc as reqd. at site (n model no. RC380B LED 42S 6500 G6 L60W60 PSU OD( Philips/Trilux )
38Supplying and fixing of street light pole box of size 8"x10" complete with all accessories i/c suitable clamps, suitable bakelite sheet, brass screws, washers and 1 Nos. SP MCB 10 amps capacity i/c making connection etc. as required at site.
39S/I/T/C of followingflood light fitting 5700k pressured dia cast housing with IP65 protection efficient high 220-240V output emitter LED for better distribution with dimension and all accessories etc. as required at site.200 watts (Model No. BVP410 LED 200CW HE NB FG S4 XTFCL) ( Philips/Trilux )
40Providing and fixing exhaust fan 900 RPM with all accessories and making connection etc as reqd if wooden work is reqd
4115" exhaust fan
4218" exhuast fan
43Supplying, fixing and laying of one number PVC insulated and PVC sheathed/ XLPE aluminium armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the same etc. as required.
444 x 16 sq.mm
453.5 x 150 sq.mm
463.5 x 185 sq.mm
47Supplying and fixing ofcubical type panel made of 14 gauge CRCA structure, base channel, doors & partition complete with Modulded case circuit breakers, meters,i/c lamps current transformer etc. complete in all respect,insulated bus bars with heat shrinkable PVC sleeve in suitable bus chambers, interconnection,small wiring, name platedanger plate, earth bus etc. & comprising of compartments with hinged door for each feeder &its accessories,cables alley with hinged doors bus chamber with bolted door etc. The panel being of dust & vermin proof construction with rubber gasket, attrectovely power coated with siemens grey shade and having orange peel finish. The panelshall be freestanding type/wall mounted type as per relevant drawing,equipment schedule, specifications i/c all materials, accessores,loose supplioed items, etc. required for for completeness of the project majority comprising of following:-
48Note:- 1) All MCCBs shall be extended type front door operating handle, phase spreaders & phase barrieries.2) Metering CTs burden shall be 15 VA & accuries class 1.0 3) CTs shall be "" Cast Resin "" type. 4) All MCCBs shall be with adjustable microprocessor based released (250 A above mccb shall be microprocessor based) 5) All Indication light shall be LED Type.6) All metere shall be Digital type.7) Breaking capacity of all MCCb"s are Ics service breaking Capicity 8) Degree of protection for panels shall be IP:52 9) Panel manufacturer shall have type test certificates for short time withstand current test of 50 KA for 1.0 sec from CPRI./Bhopal/ Banglore10) ON indication lamp shall be provided for all 3 phase MCCB/MCb out going feeders unless otherwise specified.11) Control SP MCB"s pf 2 Amp rating shall be provided for each metering circuit.
49Incoming 630amps MCCB 35 KA 3 pole – 1 Nos. Outgoing 200 amps MCCB 35 KA 3 pole – 3 Nos.100 amps MCCB 35 KA 3 pole – 3 Nos.TPN 63 amp - 3Nos. DP MCB 63 amp - 2 nos
50Supplying and fixing of cubical type panel made of 14 gauge CRCA structure, base channel, doors & partition complete with Modulded case circuit breakers, meters,i/c lamps current transformer etc. complete in all respect,insulated bus bars with heat shrinkable PVC sleeve in suitable bus chambers, interconnection,small wiring, name platedanger plate, earth bus etc. & comprising of compartments with hinged door for each feeder &its accessories,cables alley with hinged doors bus chamber with bolted door etc. The panel being of dust & vermin proof construction with rubber gasket, attrectovely power coated with siemens grey shade and having orange peel finish. The panelshall be freestanding type/wall mounted type as per relevant drawing,equipment schedule, specifications i/c all materials, accessores,loose supplioed items, etc. required for for completeness of the project majority comprising of following:-
51Note:- 1) All MCCBs shall be extended type front door operating handle, phase spreaders & phase barrieries.2) Metering CTs burden shall be 15 VA & accuries class 1.0 3) CTs shall be "" Cast Resin "" type. 4) All MCCBs shall be with adjustable microprocessor based released (250 A above mccb shall be microprocessor based) 5) All Indication light shall be LED Type.6) All metere shall be Digital type.7) Breaking capacity of all MCCb"s are Ics service breaking Capicity 8) Degree of protection for panels shall be IP:52 9) Panel manufacturer shall have type test certificates for short time withstand current test of 50 KA for 1.0 sec from CPRI./Bhopal/ Banglore10) ON indication lamp shall be provided for all 3 phase MCCB/MCb out going feeders unless otherwise specified.11) Control SP MCB"s pf 2 Amp rating shall be provided for each metering circuit.
52Incoming 400amps MCCB 36 KA 3 pole – 1 Nos.Outgoing 125 amps MCCB 36 KA 3 pole – 3 Nos.100amps MCCB 36 KA 3 pole – 3 Nos.TPN 63 amp - 3Nos. DP MCB 63 amp - 2 nos
53Providing and fixing of 10 watt Focus Track mounted LED fitting aluminium RGB light 240 volt50 HZ and having 2000 lumens and colour 3000 K including making connection etc as reqd. at site
54Providing and fixing of fancy/wall bracket light fittingincluding making connection etc as reqd. at site ( Philips /Decon )
55Providing and fixing of 4 feet 20 watt flatline ceiling suspendedfitting 2200 lumens 6500K colour temperaturewith fully diffuser in extruded aluminium housing220 to 240 V , 50 HZ and dimension ( 33 x 120 x 1200mm ) continious mounting with 1P 20 i/c making connection with suitable hanging arrangement with suspended multiple GI wire i/c mounting and frame alongwith etc as reqd. at site ( model no. SP570X LED22S 6500 PSU W12L120 OD SI)( Philips/Trilux )
56Supplying and fixing of PVC box of size 8"x10" complete with all accessories i/c suitable clamps, suitable bakelite sheet , brass screws, washers and 1 Nos. TPN 32 amp MCB capacity i/c making connection etc. as required at site.(for 3 phase AC)
57Supplying and fixing of wall mounting, vertical type, 415 V, TPN MCB distribution board double doorIP43 , sheet steel, dust protected, duly powder painted, inclusive of 250 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way MCCB 36 module ( model no. VYV12DM2-P ) ( make : Hagger)
58Supplying and fixing of 63 amp TPN MCB in the existing MCB DB and making connection etc as reqd. at site
59Supplying and fixing of 6x4 sqmmPVC sheathed and PVC insulated unarmoured copper cable for providing power supply i/c making connection as required at site.
60Supplying and fixing of 4x4 sqmmPVC sheathed and PVC insulated unarmoured copper cable for providing power supply i/c making connection as required at site.
61Providing/ fixing/ commissioning of three phasetower air conditioner with drain pump and all accessories alongwith specification as under: (a) 415 V, 3 phase, 50 Hz (b) Techology – Non -inverter type (c) Capacity – 4 ton (12000 K. Cal / hr (d) Evaporator/ Condenser material- Copper (e) Non- heating/ cooling type AC only (f) Compressor type- rotary (g)Warranty – One year or more on AC unit (h) Warranty two years or more compressor
62S/F of copper pipe with netrile insulation, lacquer coating, Tapping,brezzing etc as required at site suitable for 4 Ton tower AC of 3 phase A/C i/c ferruling, cutting, U traps (at every 7 mtrs) etc as per requirement of OEM/Engineer-incharge.
6319.05 mm and 1 mm thick
649.53 mm and 1 mm thick
65Supplying and fixing of wall/floor stand suitable for 3 phase tower A/C etc. as required. (Angle iron of 50x50x6mm thickincluding painting etc. as required at site.)
66Indoor Unit
67Outdoor Unit
68P/F of drain pipe of 25 mm dia UPVC pipe with insulation on surface/ recess i/c cutting and making good the same etc. as required. (Astral/Finolex)
69Supplying, installation, testing & commissioning of 1.5 TR 5 star invertorsplit Air-conditioner units with cordless LCD remote and indoor as well as out door unit complete with compressor, condenser fans, all internal wiring, and aluminum stand for out door unitwith at least 05 year warrenty on compressor and 2 year on complete unit etc. as required and withfollowing specifications: Technical Specifications: i) Nominal Cooling Capacity : 3501 = 5200 watt ii) Rated power supply: 220 volt /50 hz/ 1 phase iii)Compressor type: High EER Rotary - BLDC iv)Controller type : LCD RemoteV)Refrigerent R-32Vi) Make: Daikin/Ogeneral/Hitachi/Bluestar