}

Procurement Of Double Beam Uv-Visible Range Spectrophotometer For Quality Control Laboratories Running Under Cwa (W&S)-Ii Division, Haiderpur, Delhi-Delhi

Delhi Jal Board-DJB has published Procurement Of Double Beam Uv-Visible Range Spectrophotometer For Quality Control Laboratories Running Under Cwa (W&S)-Ii Division, Haiderpur. Submission Date for this Tender is 21-03-2024. Thermostats Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42881497
Procurement Of Double Beam Uv-Visible Range Spectrophotometer For Quality Control Laboratories Running Under Cwa (W&S)-Ii Division, Haiderpur
Open Tender
Indian
Delhi
Delhi
21-03-2024

Tender Details

Procurement Of Double Beam Uv-Visible Range Spectrophotometer For Quality Control Laboratories Running Under Cwa ( Wns ) -Ii Division, Haiderpur. , Specifications Of Double Beam Uv-Visible Range Spectrophotometer: Equipment Type: Benchtop Group: Chemical Analysis: Water / Wastewater Parameter: Multi-Parameters Scope: Central / Zonal Lab. Principle: Photometry Approved Make / Brands: Hach / Thermo Fischer Scientific / Agilent / Perkin Elmer / Wtw / Lovibond. The Spectrophotometer Will Be Dual Beam ( Viz. Uv-Visible ) Operation With The Reference Cell Position For Kinetics Application. It Will Mandatorily Haven 8-Cell Carousel. The Spectrophotometer Must Have Room-Light Resistance, Allowing Lid-Open Operation For Improved Speed And Convenience. The Spectrophotometer Will Have Option Of Automated Cell Changes And Cell Holders, Sipper And Fibre Optic Probes For Measurements Outside Of The Sample Compartment. It Must Accommodate High Throughput Measurement And Temperature Control. The Spectrophotometer Will Have Following Features: Spectrophotometer Will Be Double Beam ( Uv-Visible ) / Reference Cell. It Is Will Have High Resolution Touch Screen User Interface. The Spectrophotometer Must Be Capable Of Operating Through Computer Also. There Will Be 8-Position Cell Changer With Switchable Turret. It Will Have Onboard Methods, Reporting And Data Export. It Will Be Networking Capable And Will Have Wi-Fi Adaptor. It Is Capable Of Open-Lid Operation. There Will Be Room Light Resistance. It Will Have Sipper ( Optional ) It Must Accommodate Cells Up To 100 Mm Path Length. There Will Be 8-Position Cell Changer With Switchable Turret. It Must Have Optional Facility For 4-Position Cell Changer ( Long Path Cells ) And Peltier-Thermostat Single Cell Holder ( 20 °C - 60 °C ) Detector Type : Dual Silicon Photodiodes Display : 7-Inch Colour Touch Screen, High Definition, 800 × 1280 Pixels Photometric : ±0.002A At 0.5A Accuracy: ±0.004A At 1.0A Instrument : ±0.008A At 2.0A Wavelength Accuracy: ±0.5 Nm Baseline Flatness : ±0.002A Compartment:8-Position Cell Changer ( Standard Also Accommodates ( Optional ) : Peltier Thermostat Cell Holder ( 20-60 °C ) Sipper Accessory ( Optional ) Drift: ( At 500 Nm After 1 Hour Warm-Up ) <0.0005A / Hr Electrical Requirements: External Ac To Dc Converter. Voltage And Frequency ( Hz ) Selected Automatically, 100–240 Volts, 50–60 Hz. Keypad : Touch Screen Lamp : Xenon Flash Lamp ( >5 Years Typical, 3 Years Guaranteed ) Noise: ( Rms At 500 Nm 60 Consecutive Measurements ) =0.00020A At 0A At 260 And 500 Nm =0.00030A At 1A At 260 And 500 Nm =0.00040A At 2A At 260 And 500 Nm Optical Design -Double Beam Photometric Display -3A To +5A Photometric Range –2A To +3.5A Photometric Repeatability ±0.001A At 1A Measured At1.0A At 546 Nm Spectral Bandwidth- 2 Nm Stray Light-< 1.0%T 198 Nm ( Kcl ) , <0.05%T At 220 Nm ( Nacl ) , <0.03%T At 340 Nm ( Nano2 ) Wavelength Data Interval - 0.1 Nm, 0.2 Nm, 0.5 Nm, 1 Nm, 2 Nm, 5 Nm Wavelength Range - 190 Nm – 1100 Nm Wavelength Repeatability -< ±0.2 Nm Wavelength Scan Speed-Slow, Medium And Fast - Up To 1600 Nm / Min Printer-Capable To Connect With Printer Computer Operation - The Spectrophotometer Can Be Operated From Compatible Computer And Software. Computer And Operational Software To Run Spectrophotometer Will Be A Part Of The Spectrophotometer. Connections - Single Usb-A Supports Flash Memory Devices For Method And Data Storage. Duplex Usb-A On Side Supports Connection To Computer Running Optional Remote Control Software, Keyboard, Mouse Export Data To Network Or Pc Via Usb, Ethernet, Or Wi-Fi Usb Adaptor Available. Print Via Usb, Ethernet Or Wi-Fi Usb Adaptor Available Warranty:3 Year

Key Value

Document Fees
INR 500 /-
EMD
INR 34300.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Procurement of Double Beam UV-Visible Range Spectrophotometer for Quality Control Laboratories running under CWA (W&S)-II division, Haiderpur.
Sl. No. Item Description
1Specifications of Double Beam UV-visible Range spectrophotometer: Equipment Type: Benchtop Group: Chemical Analysis: Water/Wastewater Parameter: Multi-parameters Scope: Central/Zonal Lab. Principle: Photometry Approved Make /Brands: Hach/ Thermo Fischer Scientific/Agilent/ Perkin Elmer/WTW/Lovibond. The spectrophotometer will be dual beam (viz. UV-Visible) operation with the reference cell position for kinetics application. It will mandatorily haven 8-cell carousel. The spectrophotometer must have room-light resistance, allowing lid-open operation for improved speed and convenience. The Spectrophotometer will have option of automated cell changes and cell holders, sipper and fibre optic probes for measurements outside of the sample compartment. It must accommodate high throughput measurement and temperature control. The spectrophotometer will have following features: Spectrophotometer will be Double Beam (UV-Visible)/Reference Cell. It is will have High resolution touch screen user interface. The spectrophotometer must be capable of operating through computer also. There will be 8-position cell changer with switchable turret. It will have onboard methods, reporting and data export. It will be Networking capable and will have Wi-Fi adaptor. It is capable of open-lid operation. There will be room light resistance. It will have sipper(optional) It must accommodate cells up to 100 mm path length. There will be 8-position cell changer with switchable turret. It must have optional facility for 4-position cell changer (long path cells) and Peltier-thermostat single cell holder (20 °C - 60 °C) Detector Type : Dual Silicon Photodiodes Display : 7-inch colour touch screen, high definition, 800 × 1280 pixels Photometric : ±0.002A at 0.5A Accuracy: ±0.004A at 1.0A Instrument : ±0.008A at 2.0A Wavelength Accuracy: ±0.5 nm Baseline Flatness : ±0.002A Compartment:8-position cell changer (standard Also accommodates (optional): Peltier thermostat cell holder (20-60 °C) Sipper accessory (OPTIONAL) Drift:(At 500 nm after 1 hour warm-up) <0.0005A/Hr Electrical Requirements: External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz. Keypad : Touch screen Lamp : Xenon Flash Lamp (>5 years typical, 3 years guaranteed) Noise: (RMS at 500 nm 60 consecutive measurements) =0.00020A at 0A at 260 and 500 nm =0.00030A at 1A at 260 and 500 nm =0.00040A at 2A at 260 and 500 nm Optical Design -Double Beam Photometric Display -3A to +5A Photometric Range –2A to +3.5A Photometric Repeatability ±0.001A at 1A measured at1.0A at 546 nm Spectral Bandwidth- 2 nm Stray Light-< 1.0%T 198 nm (KCl) ,<0.05%T at 220 nm (NaCl), <0.03%T at 340 nm (NaNO2) Wavelength Data Interval - 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm Wavelength Range - 190 nm – 1100 nm Wavelength Repeatability -< ±0.2 nm Wavelength Scan Speed-Slow, medium and fast - up to 1600 nm/min Printer-Capable to connect with printer Computer operation - The spectrophotometer can be operated from compatible computer and software. Computer and operational software to run Spectrophotometer will be a part of the spectrophotometer. Connections - Single USB-A supports flash memory devices for method and data storage. Duplex USB-A on side supports connection to computer running optional remote control software, keyboard, mouse Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor available. Print via USB, Ethernet or Wi-Fi USB adaptor available Warranty:3 year
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail