Tender For Special Repairs To Generator Room (Bldg P-355) At Ins Valsura, Jamnagar, jamnagar-Gujarat

Military Engineer Services-MES has published Tender For Special Repairs To Generator Room (Bldg P-355) At Ins Valsura, Jamnagar. Submission Date for this Tender is 01-04-2024. Electric Generator Tenders in jamnagar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

42872573
Tender For Special Repairs To Generator Room (Bldg P-355) At Ins Valsura, Jamnagar
Open Tender
Indian
Gujarat
jamnagar
01-04-2024

Tender Details

Tender For Special Repairs To Generator Room (Bldg P-355) At Ins Valsura, Jamnagar

Key Value

Document Fees
INR 500 /-
EMD
INR 49200.0 /-
Tender Value
INR 24.60 Lakhs /-

BOQ Items

Name of Work: Special repairs to Generator Room (Bldg P-355) at INS Valsura, Jamnagar
Sl. No. Item Description
1Taking down cement plaster of any description on PCC/stone surface/brick surfaces including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
2Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
3Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for in this Schedule and removal of entire debris as ordered outside MoD land complete all as specified & as directed.
4Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.
5Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
6Dismantling of fencing wire mesh any type and any size complete all as specified & as directed.
7Dismantling of post or struts (wood, steel or RCC) any section, including taking out embedded portion in concrete and making good the disturbed ground complete all as specified and as directed.
8Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stackingserviceable tiles at site andremoval of entire debris as ordered outside MoD land complete all as specified and as directed.
9Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
10Taking down chowkat or frame with shutters (including grills, fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
11Excavating over areas not exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed.
12Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.
13Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface in soft/ loose soil complete all as specified & as directed.
14Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
15Removing excavated surplus soil to a distance exceeding 50m and not exceeding 250m and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
16M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
17M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
18M&L for PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified.
19M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops and the like including weathering, slightly rounded, chamfered angle and throating as directed including useand waste of form work (straightor curved) all exposed surface of concrete finished fair complete all as specified & as directed.
20M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinthbeams, base of columns etc., basement slabs, under-reamed piles and mass concrete including necessary formwork complete all as specified and as directed. Note: Reinforcement shall be measured and paid for separately.
21M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20 mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
22M&L for precast cement concrete (1:2:4 type B0 using 12.5mm graded crushed stone aggregate) louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4, complete all as specified & as directed.
23Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & as directed.
24Supply only Integral Water Proofing Compound (ISI Marked).
25M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed.
26Cutting chases in brick/ stone wall, pinning in, making good to facing where required and plastering in CM 1:4 to ends of edges of landing, steps, cills, lintelsetc and cutting chases not exceeding 10 cm girth for concealed water tubing and similar works and making good cutting as per its original specfication complete all as directed.
27S&F Second class hard wood kiln seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as specified and as directed.
28S&F factory made 35 mm thick second class hard wood plain framed panelled door shutter (any number ofpanels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.
29S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window / Ceosetory windows & other Frames/ Chowkhat of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/sqmm, modules of elasticity 900 N/sqmm and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: MS hold fast/ lugs/ SS dash fasteners shall be measured and paid for separately.
30S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm and resistance to spread of flame of Class A category withproperty of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer -In- Charge. Note: Stainless steel butt hinges and necessary SS screws shall be measured and paid for separately.
31S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing, powder coated aluminium snap on beading, neoprene gasket etc. complete all as specified and as directed.
32S&F aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutter, side hung type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos.), suitable handle (2 Nos.) etc. complete all as specified and as directed. Note: Glass shall be measured and paid for seperately.
33S&F 150 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
34S&F 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .
35S&F 75 mm size butt hinges, medium weight cold rolled mild steel and fixed .
36S&F 100 mm size stainless steel butt hinges (ISI Marked), medium weight.
37S&F 150 mm size extruded aluminium alloy handle (ISI Marked), cast type, anodised and fixed.
38S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
39S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.
40S&F mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Grade E-165 (Fe 290), complete, all as specified & as directed.
41S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed.
42S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work, framed and hung as gates including pintle hinges, stops, hand-made sliding bolts, etc including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed.
43S&F mild steel screw bolts of 5-10 mm diameter of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5 cm long, complete all as specified & as directed.
44S&F mild steel round bars 10mm dia and over as in tie bars fixed to fencing posts and other similar works, cut to length, bent to shape required, including cranking, bending, binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips or welding of bar at spots as directed, conforming to Grade E-165 (Fe 290), with & including painting with two coats of aluminium paint over a coat of aluminium red oxide primer after preparation of surfaces, complete all as specified & as directed.
45M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
46All as per serial item No. 45 here-in-before but bars 6 to 8 mm dia.
47All as per serial item No. 45 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders.
48S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed.
49Fixing only mild steel galvanized chain link fencing, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire. Note :- Supply only chain link fencing shall be measured and paid for separately.
50Supply only mild steel galvanized chain link fencing (Coating 120 to 140 GSM) not more than 4mm dia of mesh wire, 75mm x 75mm mesh size (or mesh size as directed) including line wire complete all as specified and as directed.
51S&F steel rolling shutters, 1.25mm thickness of laths, gear operated type with bevel gear box and crank handle, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, including dismantling & taking down the existing unserviceable rolling shutter, complete all as specified and as directed.
52M&L for cutting out cracks to "V" section in existing roofs or terrace cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & as directed.
53Material and labour for complete removal of existing water proofing treatment of any description or any other type of treatment over roof slab, parapets, chimney stacks, etc including cement plaster/PCC over RCC roof and cleaning the surface with wire brushes and washing with water, removing of insolvent materials and removing & depositing the debris, rubbish, etc outside MoD land, brushing neat cement slurry @ 3 Kg of cement per Sqm over the cleaned surface and provide 15mm thick screed bed/bedding layer/plaster in CM 1:3 mixed with integral Water Proofing Compound (WPC) as per manufacturer"s instructions and finishing the surface even & smooth without using extra cement while the cement slurry is still green on RCC roof/parapet, provide oil bound bituminous primer @ 0.30 Kg/Sqm after bedding layer/plaster is cured with water for 7 days & completely dried, provide minimum 4mm thick APP based modified polymeric water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 160 gms/Sqm with over laps 100 mm longitudinal direction (side laps) and 150 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed and finally finishing the top surface with one finishing coat of bituminous aluminium paint complete all as specified and as directed. Notes: (i) WPC shall be measured & paid for separately as ‘Supply only’. (ii)The work shall be carried out only through manufacturer or their authorised applicator and contractor shall submit a written guarantee of the manufacturer/authorised applicator for the effectiveness of WPT for 10 years from the date of completion of contract. (iii) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (iv) The net area of water proofing treatment shall be measured without any extra allowance for laps.
54M&L for average 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in roof padding, floor, levelling course, etc by maintaining gradient/ undulation, finished even & smooth without using extra cement complete all as specified and as directed.
55M&L for 75 mm thick plain cement conctere 1:3:6,type C1 (using 20 mm graded crushedstone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed. Note : Plinth protection shall be of width as directed and shall belaid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.
56M&L for 75mm thick PCC 1:4:8, type D2 (using 40 mm gradedcrushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed.
57M&L for machine cut mirror polished Kota stone slab 18 to 22mm thick laid in floors etc over & including screed bed or bedding layer of 20mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
58M&L for machine cut mirror polished Kota stone 12 to 15mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. Note : Quoted rate shall deemed to be inclusive of rendering (as screed bed).
59M&L for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
60M&L for rounding to edges of stone slabs (one edge), 18-20mm thick stone as in steps, cooking platform and other similar situations, including machine polishing to edge to give high gloss finish etc., complete all as specified and as directed.
61M&L for non skid joint free ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got appproved from GE before incorporation in the work.
62M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got appproved from GE before incorporation in the work.
63M&L for factory made M-35 grade, 60 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE.
64M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
65M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls mixed with WPC as per manufacturer"s instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid for separately as "Supply only".
66M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed.
67M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
68M&L for preparation of old surfaces of ceilings including scraping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) and applying two coats of white wash complete all as specified and as directed.
69M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified and as directed.
70M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc by hand held sander / long handle sander including cornices, pilasters etc and preparation of plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
71M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer"s instructions complete all as specified and as directed.
72M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer"s instructions complete all as specified and as directed.
73S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections exceeding 0.5 Sqm in each pane complete all as specified & as directed.
74M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
75M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamelpaint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
76Taking down or up damaged/ old GI pipe of 15 mm bore and S&F new 15 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
77Taking down or up damaged/ old GI pipe of 20 mm bore and S&F new 20 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
78S&F in repairs 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm, fixed to wall/ ceilings or in floors etc. complete all as directed.
79S&F in repairs 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
80S&F in repairs 15mm bore bib tap with wall flange, fancy type, cast copper alloy, long body, chromium plated screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6808 or equivalent in makes mentioned in Appendix "B" here-in-after.
81S&F in repairs 15 mm bore two way bib tap fancy type, brass, chromium plated with flange and aerator, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 7512 or equivalent in makes mentioned in Appendix "B" here-in-after.
82S&F in repairs 15 mm bore angle cock with wall flange, chromium plated brass, screwed both for iron pipe or brass ferrule complete all as directed. Make: Prayag Cat No. 7510 or equivalent in makes mentioned in Appendix "B" here-in-after.
83S&F in repairs 15 mm bore pillar tap, Swan neck, fancy type, long body, CP cast copper alloy, with capstan heads, with long screwed shanks and fly-nuts, screwed down high pressure, screwed for iron pipe complete all as directed. Make: Prayag CatNo. 6514 or equivalent in makes mentioned in Appendix "B" here-in-after.
84S&F in repair CP brass soap dish including fixing with brass screws complete all as specified & as directed. Make : Prayag Cat No BA-45 or equivalent in makes mentioned in Appendix "B" here-in-after
85S&F in repairs stainless steel square type grating with openable round dome 125mm dia and fixed complete all as specified & as directed.
86S&F in repairs PVC connection 15mm bore and 45cm long with two Nos of brass check nuts and washers complete all as directed.
87S&F in repairs PVC flexible waste pipe for 32mm dia waste coupling complete all as specified and as directed
88S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints laid in floors/ fixed to walls, complete all as specified & as directed.
89S&F75 mmbore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
90S&F PVC (SWR) Vent cowl 75mm bore size fixed complete all as directed.
91S&F in repairs PVC (SWR) floor trap plain with stainless steel openable grating including jointing with solvent cement, diameter of outlet 75mm, complete all as specified & as directed.
92S&F in repairs vitreous china wash hand basin, white, flat back of size 450mm x 300mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.
93S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, including lime concrete bedding and making good disturbed floor, complete all as specified and as directed.
94S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as specified and as directed.
95Dismantling of existing any type & any capacity water storage tank fixed in any description andS&F new 500 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical verticalwith close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
96S&F in repair Ball brass valve, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule of 20 mm bore and fixed complete all as specified and as directed.
97Cutting/ Chipping/ Dismantling of spall / loose damaged concrete from soffits of RCC slab / other RCC structural members in a controlled manner carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete upto good parent concrete to expose the existing reinforcement (direct hammering should be avoided) average thickness of 50-75 mm including cleaning the exposed surfaces by water jet pressure pump at 4 to 5 kg/ Sqcm pressure to remove chlorides and loose particles, air drying the surface etc for further treatment with & including all necessary tools, safety measures like helmet, safety belt, adequate labour insurance, scaffolding, etc. for height upto 15 metre from average ground level under the supervision of qualified supervisor (the damaged ceiling/ concrete shall only be measured) complete all as specified and as directed.
98M&L for cleaning existing reinforcement bars with wire brush / rotary wire brush making the surface free from cement skin, loose particles, dirt, etc and applyingrust remover/converter (Rebaklense RR of M/s Fosroc / Amandurof GK technocom or equivalent of Dr. Fixit / SIKA /Pidilite) over the corroded reinforcement bars where ever micro concreting is required and cleaning the same after application with & including all necessary tools, scaffolding, etc. for height upto 15 metre from average ground level complete all as specified and as directed.
99M&L for applying Nitobond EP (2.5 Kg pack and coverage area 5.5 Sqm/ 4.5 Kg pack and coverage area 10 Sqm) epoxy bonding agent over the old concrete surfaces including the cost of all materials, tools, scaffolding, brush etc. for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Make: Fosroc or equivalent of Krishna Conchem / Dr. Fixit / SIKA / Pidilite / BASF / Sunanda / Asian as approved by GE.
100M&L for application of high build polymer modified cement mortar (1:3) mixed with 6 ltrs SBR latex per bag of cement {Compressive strength after 28 days = 40 N/sqmm (According to ASTM C109)} in small patch work over column/ beams/ ceilings / walls surfaces 20 to 30mm thick in two layers over a coat of bonding agent like Nitobond SBR (1 ltr SBR + 3 Kg cement) applied as per manufacturer’s instructions for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Note :- SBR latex chemical shall be measured and paid for separately as ‘Supply only’.
101Supply only SBR latex chemical of Make Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian as approved by GE.
102Cleaning of 100to 150mm bore blocked Sewage lines including manholes in any depth by pressure Jet by using mechanical/ hydraulic pressure using Vehicle type hydraulic methods or modern methods and/ or manually such as by rodding, passing rope knots, bamboo fanti and disc of required size (with safety measure for gas etc) from manholes to manholes or manholes to cleaning eye or cleaning eye to clean eye until the smooth flow of sewage line is restored including taking out sludge in semi liquid stage including all water effluences etc re-fixing manhole cover and removing all materials from the site of work to outside MD land in closed vehicle and depositing in excavated earth pit of suitable size including supply and sprinkling bleaching powder and covering sludge with earth after removal of blockage etc complete all as directed. Note : Quoted rate shall deemed to be inclusive of earthwork & excavation, sprinkling sufficient bleaching powder including transporting the sludge & other materials in closed vehicle.
103E&M Items: Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
104M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etcall as per IS, terminated in & including new PVC modular box, terminal plates with all accessories, concealed PVC modular box with cover suitable for mounting fittings like switches, sockets, regulators etc with and including top cover modular plates, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
105All as per serial item No. 104 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
106All as per serial item No. 104 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
107S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed.
108S&F in repairs modular switch, single pole, one way, 16 Amp, 1 module with all accessories complete all as directed.
109S&F in repairs modular socket 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as directed.
110S&F in repairs modular socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as directed.
111S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
112Taking down existing light fitting of any description & fixed in any position and S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500, high quality design, aluminium extruded with decorative end caps fixed as per manufacturer"s instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No.LGLZ01X020XC or equivalent in makes mentioned in Appendix "B" here-in-after.
113Taking down existing light fitting of any description & fixed in any position and S&F new 10 Watt wall mounted 2 ft glaze LED batten, CCT 6500K, high quality design, aluminium extruded with decorative end caps fixed as per manufacturer"s instructions and making necessary electricalconnections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No. LGLZ01X010XC or equivalent in makes mentioned in Appendix "B" here-in-after.
114Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fittings in aluminium pressure die cast housing with toughened glass cover (IP 66 protection), having CCT 5700K and Sytem lumen efficacy >120 Lm / W, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer"s instructions and making necessary electrical connections and testing on completion, complete all as specified and as directed. Make: Jaquar Cat No. LSRT01S045XC or equivalent in makes mentioned in Appendix "B" here-in-after.
115Taking down existing flood light fitting of any description and S&F new 100 W LED flood light fitting, IP-66 rated with high pressure die cast aluminium housing, lens and toughened glass/ PC cover, lumen intensity >110 Lm / W, CCT 5700K, with & including external Surge Protection Device (SPD) 10 kV, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system and testing on completion complete all as directed. Make : Jaquar Cat No. LFLDSLM100XC or equivalent in makes mentioned in Appendix "B" here-in-after.
116M&L for Fan hook of standard type as per SSR specification including making necessary arrangements in existing RCC slab ceiling by cutting RCC slab to the required depth upto existing MS bars and tie up with new one and making good disturbed surfaces complete all as specified and as directed.
117S&F 450mm sweep, metal body, exhaust fan, AC, single phase, 230/240 V, copper winding motor, with louver shutter venti Air and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard with & including cutting, openingof required size hole (Square/ Round) through RR masonry/ brick walls for fixing exhaust fan and making good disturbed surfaces of wall with CM 1:4 and painting with two coats of existing colour to match the wall complete all as directed by Engineer-in-Charge. Note : Old Exhaust Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
118S&F 300mm sweep, metal body, exhaust fan, AC, single phase, 230/240 V, copper winding motor, with louver shutter and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard with & including cutting, openingof required size hole (Square/ Round) through RR masonry/ brick walls for fixing exhaust fan and making good disturbed surfaces of wall with CM 1:4 and painting with two coats of existing colour to match the wall complete all as directed by Engineer-in-Charge. Note : Old Exhaust Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
119S&F 250mm sweep, PVC body, exhaust fan, AC, single phase, 230/240 V, copper winding motor, with louver shutter venti Air and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard with & including cutting, openingof required size hole (Square/ Round) through RR masonry/ brick walls for fixing exhaust fan and making good disturbed surfaces of wall with CM 1:4 and painting with two coats of existing colour to match the wall complete all as directed by Engineer-in-Charge. Note : Old Exhaust Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
120S&F in repairs Distribution Board (DB) sheet metal enclosure, TPN, 4 way with 200 Amps rated bus bar, double door, 415 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
121S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 4 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
122S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, "C" Curve, complete all as directed.
123S&F in repairs MCB SPN 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, "C" Curve, complete all as directed.
124S&F in repairs MCB TPN 63 Amp, 415 V, 50 Hz, AC supply, 10kA, "C" Curve, complete all as directed.
125M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade cables (ISI marked), drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit (ISI marked) not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Notes :-(i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
126M&L for sub main wiring with two runs of 2.5 sqmm (nominal area) size main cable & one run of 2.5 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade cables (ISI marked), drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit (ISI marked) not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Notes :-(i) 02 runs of 2.5 sqmm size main cable, 01 run of 2.5 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
127Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
128Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
129Supply and laying/fixing 32 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
130Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
131M&L for Galvanized iron tubing, 80mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
132S&F perforated cable tray GI 1.6mm thick of size 150mm x 50mm for cable laying alongwith nylon tie/ clip duly fixed with proper clamping material complete all as specified and as directed.
133Dismantling and taking down existing damaged/broken PCC Pole with all fittings including Street light fittings with junction box complete all as directed.
134S&F 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 Amp, 240 V, 10 kA, "C" Curve (1 No.) & Connector (RYB&N) - 63 A Cap (01 No.)complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-6030 (BOPH-6030) or equivalent in makes mentioned in Appendix "B" here-in-after. Note: Earth work and PCC foundation shall be measured & paid for separately.
135M&L for street light bracket made from MS tubing in required size & shape at site, cut to length, bend to shape required and suitable for existing street light pole and fixing the bracket to pole with MS flat and nuts and bolts and finally painting the exposed steel surface with two coats of first quality synthetic enamel paint of approved tint over a coat of zinc chromate primer complete all as directed. Notes :-(i) Size, section and shape of MS pipe shall be as directed. (ii)Quoted rate shall deemed to be inclusive of painting. Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
136S&F 90 Watt LED street light fitting, High Efficiency IP 65 protection, CCT - 5700K, system lumen efficacy 120 Lm/W, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and toughened glass, fixing to bracket, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the system and testing on completion complete all as directed. Make : Jaquar Cat No. LSRT015090XC or equivalent in makes mentioned in Appendix "B" here-in-after.
137S&F 4 core, 2.5 sqmm PVC insulated sheathed multistranded flexible copper conductor cable (ISI marked) 1100 Volts grade complete all as specified & as directed.
138M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed.
139M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed. Notes :- (i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
140M&L for cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 120 sqmm to 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
141S&F 10mm thick chequered type insulating electrical rubber mat of size 4 x 8 ft (ISI Marked) complete all as specified & as directed.
142M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal ofsurplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
143M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing of any type. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
144S&F in repair 4mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
145M&L for galvanised iron strip 32 x 6mm earth continuity conductor or main earthing lead buried in ground / fixed on wall including taking out existing GI strip complete all as specified and as directed.