Tender For Construction Work Of Multipurpose Hall And Toilet Blocks For Boys And Girls In Govt High School Dulara At District Mahoba, Mahoba-Uttar Pradesh

Uttar Pradesh Housing And Development Board-UPAVP has published Tender For Construction Work Of Multipurpose Hall And Toilet Blocks For Boys And Girls In Govt High School Dulara At District Mahoba. Submission Date for this Tender is 19-03-2024. Toilet Bathroom Tenders in Mahoba Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42859107
Tender For Construction Work Of Multipurpose Hall And Toilet Blocks For Boys And Girls In Govt High School Dulara At District Mahoba
Open Tender
Indian
Uttar Pradesh
Mahoba
19-03-2024

Tender Details

Construction Work Of Multipurpose Hall And Toilet Blocks For Boys And Girls In Govt High School Dulara At District Mahoba

Key Value

Document Fees
INR 3540 /-
EMD
INR 111000.0 /-
Tender Value
INR 5.55 Lakhs /-

BOQ Items

NAME OF WORK: CONSTRUCTION WORK OF MULTIPURPOSE HALL AND TOILET BLOCKS FOR BOYS AND GIRLS IN GOVT HIGH SCHOOL DULARA AT DISTRICT MAHOBA
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil
2Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete.
5Providing andinjectingchemical emulsionforpreconstructional antitermite treatment andcreatinga chemical barrier underand alroundthe column pits wall trenchesbasement excavation top surface if plinth filling junctionofwall and floor, alongthe the externalperimeter ofbinding expansionjoints,surrounding ofpipes andconduits etc, complete (plinth area of the building at groundflooronly shall be measured as per I.S.6313 ( Part II 1981 ) Alderine emulsifiable concentrate or any other approved materialsuch as Heptrachlor or chordancewill be used. Therateofapplication ofchemical emulsion shallbe asfollows : (1 Treatment for masonary & foundation 5 liters pe r/ 100 Sqm.(2) Back fill inimmediate contact with foundation 7.5 liters / 100 Sqm. (3) Treatment of topsurfaceof plinth filling 5 liters / 100 Sqm. (4)Treatmentjunction of wallandthe floor 7.5 liters / 100 Sqm. (5)Treatmentofsoilalong external perimeter of building 7.5liters / 10 Sqm.(6) Treatment of soil under apronalong external perimter 5 liters / 100 Sqm.
6Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).bands,slab and beams
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
8Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
9Brick work with common burnt clay(non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
10Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
11Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
12Brick work with common burnt clay(non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
13Brick work with common burnt clay(non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
1515 mm thick plinth plaster [1 cement : 4 coarse sand]
1615 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
1712 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
18Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
19Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
20Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
21Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
22Construction of drain of size of size 150 x 150 mm along with apron including excavation,base concrete 1:4:8 in thickness of 7.5cm of and brick work in foundation 1:4( 1 cement : 4 coarse sand) and brickwork in half brick thick in foundation 25mm thick cement concrete (1:2:4 mix) flooring base and 20mm thick plaster (1:2) finished with neat cement.
23Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
24Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) Single leaf 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
25Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. b) Extra for double leaf 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screwsExtra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
26Fixing to steelorwoodenchaukhats in position (a) Door chaukhats
27Fixing to steelorwoodenchaukhats in position.(b) Window chaukhats
28Fixing to steelorwoodenchaukhats in position.(b) ventilator chaukhats
29Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
30Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification.New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm).
32Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
33Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
34Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm
35P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. (a) 250 mm x 10mm
36Providing & fixing stainless steeldoorhandleswith screwsand 150mm long.SI marked
37Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes
38Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions ofwalls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
39Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
40Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specificationsPainting wood work with Deluxe Multi Surface Paint of requiredshade. Two or more coat applied @ 0.90 ltr/10 sqm over anunder coat of primer applied @0.75 ltr/10 sqm of approvedbrand and manufacture
41Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.hot Finised welded type tube.
42Providingandfixingprecoatedgalvanisedironprofile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thicknesswithzinccoating120gramspersqmasper IS:277,in240mpasteelgrade,5-7micronsepoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of25micronsminimumtoavoidscratchesduring transportationandshouldbesuppliedinsinglelength upto 12 metre or as desired by Engineerin- charge. The sheetshallbefixedusingselfdrilling/selftapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excludingthecostofpurlins,raftersandtrussesand including cutting to size and shape wherever required.
43Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
44Centering and shuttering including strutting, propping etc. and removal of form work for : Suspended floors, roofs, landings, balconies and access platform
45Centering and shuttering including strutting, propping etc. and removal of form work for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
46Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases of columns, etc. for mass concrete
47Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, Pillars, Piers, Abutments, Posts and Struts
48Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit,with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required.
49Wiring for circuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire
50Wiring forcircuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire
51Wiring forcircuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire
52Wiring forcircuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire
53Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :20 mm.
54Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 25 mm.
55Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75 mmX75 mm)
56Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
57Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connection, painting etc. as required.
58Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps. modular socket outlet and 15/16 amps. modular switch, connection, painting etc. as required.
59Supplying and fixing followingway, three pole and neutral, sheet steel, TP MCB distribution board, 415 volts,on surface /recess,completewithtinnedcopper busbar, neutral busbar, earth bar, din bar,detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 6 way (4 + 18), Double door, horizontal type
60Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C" series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. single pole
61Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required.
62Supplying and fixing following rating,four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
63Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
64Providing and fixing of circular / hexazonal cast ironor MS sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick MS sheetwith it top surface hacked for proer bonding, top lid shall be screwed into the cost iron/MS sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shal be made of 12 mm dia MS bar bent to shape as per standard drawing.
65S/F of recess/surface/pendent mounted 10 to 15 watt LED down lighter having powder coated die cast aluminium housing with heat sink, diffuser / reflectorand driver set complete in all respect Category AAA
66Supply and fixing of LED Tube Light batten fittingsuitable for up to 1 X 22 watt LED tube light onsurface complete in all respect.Category AA
67S/F of 36 watt to 46 watt indoor recess mounting LED square fitting for Armstrong ceiling having powder coated die cast aluminium housing body with extended heat sink, diffuser of special polycarbonate material and driver set complete in all respect. Category AAA
68Supply of ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS : 374/79 and also comply with IS:1709/1984 with latest amendment the rated voltage 220/240 volts, 50 HZ single phase AC, the fan assembled should consists of down rod, blades, shackle canopies etc and with double ball bearing system.BEE 5 star rating - 1200 mm sweep
69Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6 sqmm cables, including tapping with insulating tape,etc. complete in allrespects.
70S/F of sheet steel enclosure for DP / TP / FP MCB with neutral link and earth terminal.Cat-A
71Supply & fixing of electronic Fan regulator (Modular), 120-280 V, ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer of work.
72Supply and laying of ISI marked aluminum conductor PVC / XLPE insulated armoured, served, sheathed cable 1100volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.10 sqmm 2core
73Supply and laying of ISI marked aluminum conductor PVC / XLPE insulated armoured, served, sheathed cable 1100volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.10 sqmm 4 core
74Supply and fixing brass nickel plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor.10 sqmm 4 core
75Supply & fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge.10 sq.mm.
76S/f of 10/20 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
77Supplying and fixing metal box of following size (nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in fromt including paintingetc. as required.75 mm x 75 mm x 60 mm deep
78Supplying and fixing followingway, three pole and neutral, sheet steel, TP MCB distribution board, 415 volts,on surface /recess,completewithtinnedcopper busbar, neutral busbar, earth bar, din bar,detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB / RCCB / Isolators).4 way (4 + 12), Double door, horizontal type
79Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
80Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure withcover plate having locking arrangement and watering pipe 2.7 m long etc, with charcoal/coke and salt as required.
81Earthing withGI earth pipe4.5 mtr long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc, with coke and salt as required.
82Supplying and laying25 mm x 5 mm. G.I. strip at 0.50 M. below ground as strip earth electrode, including connection and terminating with nut, bolt, spring, washer etc as required (jointing shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50 mm).
83Providing and fixing 6 SWG dia G.I. wire onsurfaceorin recessfor loop earthing as required.
84Providing and layingearthconnections from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipefromearth electrode as required.
85S/F of recess/surface/pendent mounted 6 to 8 watt LED down lighter having powder coated die cast aluminium housing with heat sink, diffuser / reflectorand driver set complete in all respect Category AAA
86Supply and fixing brass nickel plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor.50 sqmm 3 1/2core
87Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work.600x480x200 mm. size
88Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followedby two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work.600x480x200 mm. size
89Supplyof AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.300mm sweep.
90Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
91Providing and fixing white vitreous china pedestal type water closet( European type W.C. pan ) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid.
92Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever requirea)White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap.
93Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Felxible pipe b) 40mm dia
94Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
95Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore
96Providing and fixing CP Brass 32 mm sizeBottal Trap of approved quality & make and as per thedirection of Enginer-in-charge.
97Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.
98Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms
99Providing and fixing ofupvc SWR ring fit pipe of class B of ISI mark Confirming to IS code 13592 (make prince, supreme finolex) in internal works of toilet and RWP etc. including fixing with rubber rings etc. including cost of all material, labour etc. complete.including excavation & trenches etc complete.a) 110mm diameter
100Providing and fixing of UPVC SWR ring fit pipe of class B of ISI mark Confirming to IS code 13592 (make prince, supreme finolex) in internal works of toilet and RWP etc. including fixing with rubber rings etc. including cost of all material, labour etc. complete including excavtion trenches etc comp.b) 160mm diameter
101Haunching of SWR pipe 90mm or 110mm OR 160 MM DIA with pcc 1:5:10 cement concrete ( 1 cement:2 coarse sand:4 stone grit) ch-25 item no.2
102Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.(ch-23 sec 34)
103Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735.(ch-23 item no.38) Size 75/90 mm
104Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735.(ch-23 item no.38) Size 110 mm
105Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. a) 110mm
106Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
107Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipea) 32mm dia
108Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm diameter
109Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC]
110Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brassincluding painting of fittings and brackets, cutting and making good the walls and floors wherever required a) Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
111Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 20mm dia nominal outer dia pipes
112Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 25mm dia nominal outer dia pipes
113Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall32mm dia nominal outer dia pipes
114Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 16mm dia nominal outer dia pipes
115Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes
116Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 32mm dia nominal outer dia pipes
117Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.45 cm length i) 15mm nominal bore
118Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore
119Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore
120Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore
121Providing and fixing gun metal gate valve with wheel of approved quality(screwed end).. 25mm dia nominal bore
122Providing and fixing gun metal gate valve with wheel of approved quality(screwed end).. 32mm dia nominal bore
123Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.25 mm nominal bore
124Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank For 500 litres.
125Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore
126Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm
127Providing and fixing brass stop cock of approved quality.a) 15 mm nominal bore
128Providing and fixing brass stop cock of approved quality.a) 20 mm nominal bore
129Providing and fixing square mouth S.W. Gully trap grade "A" complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm.size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.a) 150 x 100 mm. size P type
130Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 900x800mm and 500mm deep including CI cover with frame With FPS bricks of class designation 75
131Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design :Inside size 900x800mm and 500mm deep including CI cover with frame (With FPS bricks of class designation 150)Inside size 900x1200 mmm & 1.0 meter deep including C.I. cover with frame
132Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : (For pipes 100 to 250 mm diameter)
133Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in-Charge. External work.32mm nominal bore.
134Hanching of CPVC pipe with PCC 1:5:10 ( 1 cement: 5 coarse sand: 10 stone grit) of cross section 200 x 200 mm concrete
135Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.32mm
136Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm dia nominal bore
137Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
138Providing and fixing C.I. tee at the inlet and outlet of septic tank.
139Providing & fixing 75mm dia vent pipes.
140Providing & fixing of 75mm dia cast iron terminal guard.
141Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter
142Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. L.D. -2.5- Circular shape 450mm internal diameter
143Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. Bricks
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy