Tender For Removing Of Loose Dry Sandstone Cladding And Replacement With Plaster And Paint Work On Exterior Wall Face Of Civil Lines Metro Station Downtake Pipe Work Miscellaneous Repair Works On Msor To Bicp Section Of Jaipur Metro, jaipur-Rajasthan

Jaipur Metro Rail Corporation Limited-JMRC has published Tender For Removing Of Loose Dry Sandstone Cladding And Replacement With Plaster And Paint Work On Exterior Wall Face Of Civil Lines Metro Station Downtake Pipe Work Miscellaneous Repair Works On Msor To Bicp Section Of Jaipur Metro. Submission Date for this Tender is 24-04-2024. Civil Work Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42852070
Corrigendum : Tender For Removing Of Loose Dry Sandstone Cladding And Replacement With Plaster And Paint Work On Exterior Wall Face Of Civil Lines Metro Station Downtake Pipe Work Miscellaneous Repair Works On Msor To Bicp Section Of Jaipur Metro
Open Tender
Indian
Rajasthan
jaipur
24-04-2024

Tender Details

Removing Of Loose Dry Sandstone Cladding And Replacement With Plaster And Paint Work On Exterior Wall Face Of Civil Lines Metro Station Downtake Pipe Work Miscellaneous Repair Works On Msor To Bicp Section Of Jaipur Metro

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Apr-2024 CORRIGENDUM-01 Date 22-04-2024
2 22-Apr-2024 CORRIGENDUM02 Date 24-04-2024

Key Value

Document Fees
INR 5000 /-
EMD
INR 979952.0 /-
Tender Value
INR 4.89 Crore /-

BOQ Items

Name of Work: Removing of Dry Sandstone Cladding, doing Plaster on removed surface and Painting Work on exterior wall face of Civil Lines Metro Station, fixing of downtake pipe work from viaduct to ground level, Construction of boundary wall at NAMT metro station and other miscellaneous repair works from MSOR to BICP of Jaipur Metro.
Sl. No. Item Description
1Part A: Miscellaneous Civil Works like leakage treatment (RC Gutter and Track Slab Joint) at metro stations MSOR-SICP
2Providing and applying integral crystalline slurry of hydrophillic in nature for water proofing for water proofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoirs, sewage and water treatment plants, tunnels/subways and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 Parts integral crystalline slurry : 2 parts water) for verical surface and 3:1 (3 Parts integral crystalline slurry : 1 parts water) for horizontal surfaces and appying the same from negative (internal) side with the help of synthtic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% comapred with control concrete as per DIN-1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self - healing of cracks upto a width of 0.50mm. The works shall be carried out all complete as per specifications and directions of the Engineer-In-Charge. The product performance shall carry guaranteed for 10 Years against any leakage. (For horizontal surface 01 coat @1.10 Kg/Sqm)
3Supplying and installation of OMEGA seal joint for repair of expansion joint with all tools and plants provided for the full width of the track bed and leak tightness of all joints. Works shall be carried out as per instructions of Engineer-In-Charge. Work shall be carried out only during block period. Expansion joint type described here after is the "OMEGA TYPE EXPANSION JOINT" as per IRC 83 Part-II (Refer: Technical specification of contract)
4Designing Providing, fabricating and erecting hot dipped galvanized "RAIN WATER GUTTER" using mild sheet including all accessories connections sleeves for connecting rain water pipes to gutter placed at roof along all valley and edges of building including site welding at all joints to make water tight including painting as per specifications.
5Part C: Manufacture,supply,installation, testing, and commissioning of signage and graphics for six elevated metro station (Mansarovar, New Atish Market,Vivek Vihar, Shyam Nagar, Ram Nagar, civil line) for corridor Mansarovar to Chandpole of jaipur metro Phase-1A.
6Grouting of railing base plate at viaduct with Conbextra GP-2 or other similar material complete as per directions of Engineer-In-Charge
7Grouting of Check rail bracket at Curves of track with grouting material Sikadur 53 UF make complete as per directions of Engineer-In-Charge
8Providing and prestressing of shear key bars of 36 mm of approved make complete as per directions of Engineer-In-Charge.
9Providing and prestressing of shear key bars of 42 mm of approved make complete as per directions of Engineer-In-Charge.
10Non- IIIuminated Signs Providing and fixing Non- IIIuminated signs including all operations from fabrication to installation all complete as per relevant drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in- charge.
11Sign Elements Sign frame The sign frame shall be made out of CRCA mild sheets fabricated and providing with CRCA mild stel support channels welded to sign frame, sign frame including channel supports are to be powder coated to match Grey RAL 7046 or in color duly The inside edge of sign frame to have EPDM gasket it gets in contact with the sign panel. All powder coating shall be done
12Sign Panel providing and fixing sign panel made out of 1.6 mm thick Aluminum sheet fabricated to required size and shape, both sides powder coated to required color with screen printed geaphics/ sign text as pr signage in color to match in color duly approved by Engineer-in-charge and complete graphic protected with lacquer coations. (screen printing is to be done as per technical specifications and drawings and according to directions of Engineer-in-Charge. For double sided signage, where screen printed graphic/ sign text are to be provided on both faces, the sign panels a descibed above are to be provided on each side of sign frame.
13Back panel: In single sided sign where screen printed graphic/ sign text is to be on one side, are to be provided with 0.8 mm thick CRCA mild steel back panels fabricated to required size and shape as per fabrication drawings and are to be powder coated to match Grey RAL 7046 or any other color as duly approved by Engineer-in-providing and fixing of pictogram panels in CRCA mild steel of required sizes and shape as per fabrication drawings. For double sided singage, where screen printed graphic/ sign text are to be provided on both faces and are to be powder coated to match any other color as duly approved by Engineer-in-Charge.
14Accessories: providing and fixing all accessories such as spring clips, anchoring hooks, nuts, cleats, screws hooks and slots etc. complete as per specified fabrication drawing.Above description generally holds good for the following signage except due modifications due to their respective finished dimensions and fixing arrangements:-
15Directional signs Providing and installing of signage as described in "" 1.0"" above and complte as per fabrication drawing no. 1.1.3 including providing and installing following fixing arrangements as the case may be:
16Non- Illuminated Directional Sign(Face mounted): The sign frame is to be mounted on Brick/ RCC wall backing with cladded or non-cladded. Item to include CRCA mild steel sign frames of required size and shape including mounting the sign frame on the RCC/Brick wall backing by drilling holes of required dia in the RCC/brick wall and anchoring the sign frame using steel-Dash fasteners and providing and fixing all items and accessories complete as per drawing no. 1.1.4-face for following panel sizes.The mounting surface shall be required or finished as per surrounding area complete at no extra cost. This sign is to be necessarily single sided only.
17sign panel size excluding sign Depth bends.
181500×400 40mm s
19Non- Illuminated Signs Providing and fixing Non- IIIuminated signs including all operations from fabrication to installation all complete as per relevant drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in- charge.
20Sign Elements Sign frame The sign frame shall be made out of CRCA mild sheets fabricated and providing with CRCA mild stel support channels welded to sign frame, sign frame including channel supports are to be powder coated to match Grey RAL 7046 or in color duly The inside edge of sign frame to have EPDM gasket it gets in contact with the sign panel. All powder coating shall be done
21Sign Panel providing and fixing sign panel made out of 1.6 mm thick Aluminum sheet fabricated to required size and shape, both sides powder coated to required color with screen printed geaphics/ sign text as pr signage in color to match in color duly approved by Engineer-in-charge and complete graphic protected with lacquer coations. (screen printing is to be done as per technical specifications and drawings and according to directions of Engineer-in-Charge. For double sided signage, where screen printed graphic/ sign text are to be provided on both faces, the sign panels a descibed above are to be provided on each side of sign frame.
22Back panel In single sided sign where screen printed graphic/ sign text is to be on one side, are to be provided with 0.8 mm thick CRCA mild steel back panels fabricated to required size and shape as per fabrication drawings and are to be powder coated to match Grey RAL 7046 or any other color as duly approved by Engineer-in-providing and fixing of pictogram panels in CRCA mild steel of required sizes and shape as per fabrication drawings. For double sided singage, where screen printed graphic/ sign text are to be provided on both faces and are to be powder coated to match any other color as duly approved by Engineer-in-Charge.
23Accessories providing and fixing all accessories such as spring clips, anchoring hooks, nuts, cleats, screws hooks and slots etc. complete as per specified fabrication drawing.Above description generally holds good for the following signage except due modifications due to their respective finished dimensions and fixing arrangements:-
24Directional signs Providing and installing of signage as described in "" 1.0"" above and complte as per fabrication drawing no. 1.1.3 including providing and installing following fixing arrangements as the case may be:
25Non- IIIuminated Directional Sign(Face mounted) The sign frame is to be mounted on Brick/ RCC wall backing with cladded or non-cladded. Item to include CRCA mild steel sign frames of required size and shape including mounting the sign frame on the RCC/Brick wall backing by drilling holes of required dia in the RCC/brick wall and anchoring the sign frame using steel-Dash fasteners and providing and fixing all items and accessories complete as per drawing no. 1.1.4-face for following panel sizes.The mounting surface shall be required or finished as per surrounding area complete at no extra cost. This sign is to be necessarily single sided only.
26sign panel size excluding sign Depth bends.
271800×400 40mm s
28Non-IIIuminated Directional sign -(Suspended)The sign frame is to be suspended from metal supporting members or concrete e.g. slab or beam, trusses or purlins etc by Mild steel suspenders roads of required size and lengths including all accessories like adjuster, stoppers, sleeves, bolts etc. complete as per drawing no. sus-a, sus-b(1), sus-b(2) for following sizes. All mild steel, to be polyurethane painted, shall be Hot Dipped Galvanized after fabrication and before painting.Entire assembly of suspension system is to be polyester powder coated. Hilti fasteners of specified diameters are to used where anchoring is to be done with the concrete members. The mounting surface shall be required or finished as per surrounding area complete at no extra cost.Ms Cleats made of 3mm thick SHS, as per fabrication drawings,for fixing suspenders with protal at platform level have to be provided alongwith sign of approx length of 2m or as per finalised Cleats to be welded with portal and paint to match portal color.
291200×400 80mm
301500×400 80mm
311800×400 80mm
322100×400 80mm
33Door Name SignProviding and fixing plated type Graphics sign made out of 1.5mm thick stainless steel, fabricated to required sizes and shape, including corners and edges properly rounded and dressed. Item to include chemical etching of designated graphics/text in required color on the face side and fixing to RCC/Wall surface/Wooden doors as required with the stainless steel counter sunk cross headed screws of req uired length and did. including providing necessary washers, PVC/Rubber spacers etc.
34350×200
35Fire Exit Slgn- (Suspended through suspenders)The sign frame is to be suspended from metal suppoting members or concrete e.g. slab, beam, trusses or purlins by Mild steel suspenders roads of required size and lengths including all accessories like adjuster, stoppers, sleeves, bolts etc. complete as per drawing no. sus-a, sus-b(1),sus-b(2) for following sizes. All mild steel, to be polyurethane painted, shall be Hot Dipped Galvanized after fabrication and befor painting. Entire assembly of suspension system is to be polyester powder coated. Hilti fasteners of specified diameters are to used where anchoring is to be done with the concrette members.
36MS Cleats made of 3mm thick SHS, as per fabrication drawings, for fixing suspenders with protal at platform levl have to be provided alongwith sign of approx lenth of 2m or as pr finalised Cleats to be welded with portal and paint to match protal color.
37sign panel size excluding sign Depth sign bends.
382100×400 200mm Double sided
39External sign providing and fixing external signs including all operations from fabrication to installation all complete as per relevant drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
40Totem SignProviding and fixing Totem sign -illuminated type (mentioning the station name and logo / emblem of the Metro Railway on either side ) including all operations fro fabrication to installation complete, including all accessories, technical specifications and signage schedule.
41It comprises of logo panel and station name panel to be made out of Aluminum sheet fabricated to be specified size shape and & curvature and powder coated as per drg. With laser cut text & graphic as mentioned, in signage schedule. Item to include providing and fixing sign frame (for supporting the panel frame ) of formwork of mild steel ISMC channel made up in two parts , one on the nearer side of column post other on far side of the post properly braced with MS angle tie members welded to the sign panel frame and post. providing specified number of Aluminum flats each of required size and shape to support the luminaries. providing top and bottom cover sheets in ltem to include powder coating all Aluminum sheets, sign frame and angles to required color, providing Mild steel SHS brackets in two parts in required metal shutter opening for control switch as shown in the drawing. Providing required fixing of brackets on columns, mounting the sign on the brackets, providing and fixing all accessories, angles, T- section,gusset plates base plates etc. ItemThe sign nshall be internally illuminated with 12 NOS W - T-5(16W) fluorescent lamps, 6 NOS, on either side (4 NOS on lower half with station name and 2 NOS of upper half showing logo)as per drawings, makes and specifications specified for electrical works. The job includes the following - Interconnecting wiring within the sign - installation of 6A SPN MCB in built -up pole box. - wiring from pole box to the sign through the pole itself. - terminating and connecting the incoming cable laid by DMRC at the pole box including supply of requisite material such as gland, thimbles, screws, connectors etc.
42- Making each connection with earth conductor laid along with incoming cable connecting to DMRC System
43Wiring with in the sign and from pole box to sign shall be as per size and specifications mentioned in the additional specifications
441800X1000 mm Side-four
45Illuminated Picto PanelProviding and fixing CRCA mild steel Picto-Panel powder coated to match blue with laser cut graphics and Picto gram and to be illuminated through luminare as specified. Item to include providing and fixing opal white poly carbonate sheet of required Illuminaed Title bandTitle band is to be provided with mild steel panel powder coated to match blue with laser grphic and is o be lit insie through luminare as specified. Item to inclue providing and fixing Opal white poly carbonate shet of required size and fixing it to title band panel.Non-Illuminated information PanelsProviding and ifxing non-illuminated information panels made out of aluminium sheet and fabricated to required size an ahpe powder coated to match blue or as apporved by Engineer-in-Charge with screen printed graphic as per signage schedule. Item also includes providing 6mm thick clear toughened glass and fixing it to front of information panl as per dwg.PostProviding and fixing SHS mild steel post as per Fabrication Drg no-5.1.3-Post, the sign frame and sign panels for Non-illuminated Identification Band, Illuminated Picto Panel, Illuminated Title Band and non-illuminated inormation panels etc. shall be fixed as per drg and as directed b and to the satisfaction of engineer incharge complete as per drawing.
46As per Fabrication dwg no 5.1.3-Face mounted (1200x1800)
47Route Map Sign at PlatformProviding and fixing Route Map sign at platform complete include sign panel made out of Aluminum sheet fabricated to required size and shape, both sides powder coated to required colour with screen pronted graphics/sign text as per signage schedule in colour duly approved by Enginer-in-Charge.Sign FrameThe sign frame shall be made out of CRCA mild steel sheets fabricatd and provided with CRCA mild steel support channels welded to sign to frme. Sign frame are to be powder coated to match Grey RAL 7046 or in color duly approved by Engineer-in-Charge.Sign PanelProviding and fixing sign panel made out of Aluminum sheet fabricated to required size and shape, both sides powder coated to required color with screen printed graphics/sign text as per signage schedule in color duly approved by Engineer-in-Charge and complete graphic screen printing is to be done as per technical specifications and drawings and according to directions of Engineer-in-Charge.
48Back panelSign to be providing with CRCA mild steel back panels fabricated to required size and shape as per fabrication drawings and are to be powder coated to match Grey RAL 7046 or any other color as duly approved by Engineer-in-Charge.Horizontal Box SectionProviding and fixing 3mm thk. RHS mild steel horizontal box section with adjustable box section finished with PU paint as per Fabrication Drg no-1.2.3a & b, shall be fixed as per drg and as directed by and to the satisfaction of engineer incharge complete as per drawing.
49Sign panel size excluding =3400x500, Sign Depth=40mm, Sign bends=single side
50Platform name sign with information panelsproviding and fixing platform name sign with information panels including all operations from fabrication to installation all complete as per relevant drawing, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.Non illuminated signsign - Frameto required sizes and shape.Sign frame to be powder coated to match Grey RAL 7046 or in color duly approved by Engineer-in-Charge. All powder coating shall be done on all internal as well as external surfaces.Sign- Panelsproviding and fixing sign panel made out of 1.6 mm thick aluminum sheet fabricated to required size and shape finished with powder coating of approved to required size and shape finished with powder coating of approved color, Item to include screen printed graphic/text as per signage schedule and drawing on the front of sign panel.
51Back PanelsSide are to be provided with 0.8mm thick CRCA mild steel back panel and back panel is to be powder coated to match Grey RAL 7046 or any other colour as duly approved y Egineer-in-Charge.Above description generally holds good for the folloieing signage unles otherwise specified:Providing and installing of signage complete as per fabrication drawing nos. 1.2.3a & 1.2.3bThe sign comprises of logo sign as described in 1.2 with horizontal box section is to be fixed to support brackets which are welded to existing steel portals. Item to include all operation from fabrication to instatllation as per drg. mounted on MS box section. Item to include all operation from fabrication to installation as per drg
52As per fabrication drawings no 1.2.3a & 1.2.3b
53Statutory Signs Providing and fixing statutory sign complete including all accessories, Item to include plated type graphic signs made out of aluminium sheet fabricated to required size and shape including corners and edges properly rounded and dressed punching necessary holes of required dia, pure Polyester powder.
54Providing and fixing plated type graphic signs made out of Aluminium sheet fabricated to required size and shape inluding corners and edges properly rounded and dressed punching necessary holes of required dia, pure Polyester powder coating on both sides and all edges in required color screen printing of designated graphic/text in required color on the face side (screen printing to be done as per specifications and in accordance with the sign schedule and directions of Engineer-in-Charge)and protected with lacquer coating including fixing to RCC/Brick wall backing by drilling holes of required dia. in the RCC/brick wall backing (cladded or non-cladded) stainles steel screws counter sunk cross headed screws of required length and dia including providing necessary washers. PVC/Rubber spacers etc. complete as sigage schedule and directions of the Engineer-in-charge which shall be final conclusive and binding.
55Sign panel size excluding bends sign Depth
56150x300 single sided 2mm
57200x150 single sided 2mm
58200x200 single sidee 2mm
59900x30 single sidee 2mm
60Part E: Structural repair and waterproofing works at Metro stations of JMRC Phase 1A
61Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joiningwith cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
62Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mmat required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge.
63Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge.(The payment shall be made on the basis of actual weight of approved grout injected.) Epoxy injection grout in concrete/RCC work of approved make.
64Providing and applying crystalline mortar by mixing in the ratio of 4.5: 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 ?45 MPa and adhesive bond strength Class R3 ?1.5 MPa. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat.
65Part G: Painting of platform Roof structure (Steel PEB Structure) of mainline stations of Jaipur Metro Phase 1 A from Mansarovar to Sindhi camp Metro Station (Total 08 Elevated Stations)
66Cleaning the surface with detergent, wire brush, tools (inaccessible area) and making dust free. The work shall be carried out as per direction of Engineer in Charge and include all labour, materials, tools, plants, ladder scaffolding, spider, safety belts etc all complete (Surface preparation to acheive St2).
67Removing of old paint, rust with help of power tool and preparing the surface to various standards (ASA 3.0) before application of primer. The rate will include all tools, plants, labour and other consumables and incidental charges. Nothing shall be paid extra. Except NBSR no.1, 3,4,5 and 6. The surface which are not accessible with the help of power tool shall be prepared with wire brush.
68Covering the flooring with terpoline to avoid any stain marks at floors on daily basis including labor charges for spreading and rolling back daily (The dust collected should be disposed off to the specified place)
69Providing and fixing the spider safety net made of polypropelene rope in double lesh having thread size 6 mm X 12 mm with grid 100 mm X 100 mm, upto the height of 15 metres at the platform of shed with necessary scaffolding, ladder, machine etc. with all lead, lift, ascent, decent and transportation etc. as per direction of Engineer-in-charge. The spider safety net provided, shall be retained in position at site continuously including shifting the spider net from one location to another location as many times as required during the execution of the entire work till its completion. Rate includes its maintenance for damages with additional materials, all highly skilled and semi skilled labour , equipments required to execute the job. The spider net shall not be removed without prior approval of Engineer in charge. Work will be carried out strictly in non operational hours as per direction of Engineer-in-charge.
70Applying surface tolerant epoxy coating in two coats with epoxy based primer with minimum DFT of 200 microns at all locations wherever required and volume of solids not less than 75%. Paint is to be applied with spray painting, in place where its inaccessible it may be applied with brush (item to be used where surface is having scaling.)
71Application of finishing coat epoxy polyurethane system of approved quality brand ot UV resistant coat at all locations and colour to achieve smooth & even surface with minimum volume of solids 57% and of 75 microns thickness of surfaces.
72Part H: Misslaneous Repair Work of Buildings
73Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand),including pointing with white cement mortar 1:2 (1 white cement : 2stone dust) with an admixture of pigment matching the stone shade. Red sand stone
74Supplying and fixing rolling shutters of approved make, made of 80 x 0.8mm color coated G.I Laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets of M.S, side guides of G.I and arrangements for inside and outside locking with push and pull operation complete including cost of sring hooks, providing and fixing necessary 45.0 cm. long wire springs grade No-02 including dismantling of existing rolling shutter as per the directions of Engineer-In-Charge.
75Colour Coated G.I Top Cover 0.5mm thick for rolling shutters as per instructions of Engineer-In-Charge.
76Providing and laying polished Marble stone/Sandstone work of size as specified below, of approved colour/pattern with 8 mm thick blue pottery tile inlay fixed inside 10 mm deep rebate in marble, at all levels for wall lining/columns (veneer work) by mechanical arrangement with S.S. Cramp/brackets, Anchor bolts, 5 mm vertical S.S. of approved make. Inserts as per drawings and specifications. The cost for making necessary grooves in the stone to accomodate the vertical inserts, grooves all-around stone pieces, making 10 mm deep rebate for tile inlay, chamfering of corner edges and polishing are included. Payment for Blue pottery tile shall be made separately.
77Banswara White Marble size 1900x600x35mm minimum thick
78Providing and fixing 8 mm thick blue pottery tile hand made with ground quartz stone powder of shade and surface pattern as approved by Engineer-in-charge, and of size 100x100mm with araldite or equivalent approved adehsive inside 10mm deep rebate in marble wall surfaces.