| 1 | Construction of 11KV 3P3W HT Line using 80sqmm AAA Conductor and 11mtr Long WPB Pole 0.7Km (Span Length-40mtr). |
| 2 | Supply & installation of all reqd. materialsfor11 mtr. Long 160 x 152mmWPB GI (30.44 Kg/m)with excavation of pole pit in all kind of soil (of depth 1.8 m) providing concrete base plate or base paddingand mass concreting of the pit with 1:1.5:3 of size(0.5x0.5x1.8 m) & coping (of size 0.475*0.475*0.5m-above GL) with 1:1.5:3 concrete by using 12mm HBG metal complete with curing as required & complete as per technical specification and direction of E.I.C. |
| 3 | SITC ofCoil type earthing as per technical specification and direction of E.I.C. |
| 4 | SITCof 11 kVV cross Arm (G.I.) (10.2Kg each) along with G.I. Back Clamp (2.9 Kg) complete as required complete& as per technical specification and direction of E.I.C. |
| 5 | SITC of 11KV F Clamp GI, 2.9Kg each. |
| 6 | SITC of GI Channel 100×50×6mm,st cross arm, 1.2mtr long, 20nos & 0.2mtr long 20Nos including top piece. |
| 7 | SITCof Disc Insulator (B & S) 70 kN Polymer |
| 8 | SITCof Hardware Fitting(B & S) 3 bolt |
| 9 | SITC of 11KV Pin Insulator 320 CD, Polymeer Type. |
| 10 | SITC of PG Clamp for 80mm2 AAA Conductor (Cut Point). |
| 11 | Supply fabrication and installation of Fish plate 50 x 8mm 3.14kg/mtr each 0.280 m length Complete in all respect as per the specification and direction of EIC. |
| 12 | SITCof HT(11 kV) Stay sets foroverhead line including excavation & mass concreting of stay pit(ratio 1:2:4-(0.5 m x 0.5m x0.8 m using 4 cm size hard granite metal) , stay binding etc.complete with HT stay insulator, stay clamp & bow, stay plate ,stay rod,7/10 SWG G.I. Stay wire , Grade-2, thimble etc.complete as required and per technical specification and direction of E.I.C. |
| 13 | Supply and Laying of 80mm2 AAA Conductor. |
| 14 | SITC of No.6 GI Wire for guarding 1no. |
| 15 | SITC of 75×40×6mm MS Channel for st cross arm (2.2mtr ×4pc) (9.2Kg/mtr) forguarding 1No with Galvanisation Charges. |
| 16 | SITC ofGI Pipe Earthing for 1no of road cross guarding 40 mm Dia medium Gauge 3 mtr Longincluding Material for earthing including brick masonry work for earth pit chamber (2\"×2\") etc.and RCC slab cover including salt, Charcoalcomplete as required and per technical specification and direction of E.I.C. |
| 17 | SITC of GI Flat (25×4)mm for earthing of road cross guarding -2No. |
| 18 | Supply & fixing ofG.INut, Bolt & Washers of different sizes as required. |
| 19 | SITCof 11 kVDanger Plate with back clamp made of25×3mm GIflat, (0.59Kg/mtr.) with bolting as required and complete. |
| 20 | SITCofAnticlimbing Device (3Kg per support) with back clamp 25×3mm GIflat complete with bolting. |
| 21 | Sundries (Aluminum binding tap, insulating tap ete) |
| 22 | Construction of 11KV DP with WPB GI Pole for 400A AB Switch- 1No. |
| 23 | Supply & installation of all reqd. materialsfor11 mtr. Long 160 x 152mmWPB GI (30.44 Kg/m)with excavation of pole pit in all kind of soil (of depth 1.8 m) providing concrete base plate or base paddingand mass concreting of the pit with 1:1.5:3 of size(0.5x0.5x1.8 m) & coping (of size 0.475*0.475*0.5m-above GL) with 1:1.5:3 concrete by using 12mm HBG metal complete with curing as required & complete as per technical specification and direction of E.I.C. |
| 24 | SITC ofCoil type earthing as per technical specification and direction of E.I.C. |
| 25 | SITC of Top Pressure Channel (100×50×6)mm GI,2.8mtr long 2Nos (9.2Kg/mtr). |
| 26 | SITC of Bracing channel (75×40×6)mm GI, 2.8mtr long, 2Nos (6.8mtr/Kg). |
| 27 | SITC of Cross Bracing channel (50×50×6)mm GI, 4.0mtr long, 2Nos (4.5mtr/Kg). |
| 28 | SITC of AB switch mounting channel (75×40×6)mm GI, 2.8mtr long, (6.8mtr/Kg). |
| 29 | SITC of Supporting channel for AB switch handle (75×40×6mm MS channel), 0.6mtr long 1No, 6.8Kg/ mtr. |
| 30 | SITCof Disc Insulator (B & S) 70 kN Polymer |
| 31 | SITCof Hardware Fitting(B & S) 70 kN, 3 bolt |
| 32 | SITC of 11KV Pin Insulator, Polymer Type. |
| 33 | SITC of 11KV AB Switch 3 Pole, 400Amp. |
| 34 | SITC of 11KV Lightning Arrestor 12KV, 10KA. |
| 35 | SITCof HT(11 kV) Stay sets foroverhead line including excavation & mass concreting of stay pit(ratio 1:2:4-(0.5 m x 0.5m x0.8 m using 4 cm size hard granite metal) , stay binding etc.complete with HT stay insulator, stay clamp & bow, stay plate ,stay rod,7/10 SWG G.I. Stay wire , Grade-2, thimble etc.complete as required and per technical specification and direction of E.I.C. |
| 36 | SITC ofGI Pipe Earthing for 1no of road cross guarding 40 mm Dia medium Gauge 3 mtr Longincluding Material for earthing including brick masonry work for earth pit chamber (2\"×2\") etc.and RCC slab cover including salt, Charcoalcomplete as required and per technical specification and direction of E.I.C. |
| 37 | SITC of GI Flat (25×6)mm, for earthing. |
| 38 | SITCof 11 kVDanger Plate with back clamp made of25×3mm GIflat, (0.59Kg/mtr.) with bolting as required and complete. |
| 39 | SITCofAnticlimbing Device (3Kg per support) with back clamp 25×3mm GIflat complete with bolting. |
| 40 | Supply & fixing ofG.INut, Bolt & Washers of different sizes as required. |
| 41 | Sundries (Aluminum binding tap, insulating tap ete) |
| 42 | Erection of 13mtr WPB Pole due to Crossing of 11KV Line- 02No. |
| 43 | Supply & installation of all reqd. materialsfor13 mtr. Long 160 x 152mmWPB GI (30.44 Kg/m)with excavation of pole pit in all kind of soil (of depth 2.2 m) providing concrete base plate or base paddingand mass concreting of the pit with 1:1.5:3 of size0.51*0.51*2.1 & coping (of size 0.475*0.475*0.5m-above GL) with 1:1.5:3 concrete by using 12mm HBG metalcomplete with curing as required & complete as per technical specification and direction of E.I.C. |
| 44 | SITC ofCoil type earthing as per technical specification and direction of E.I.C. |
| 45 | SITCof 33 kVV cross Arm (G.I.)(22Kg each)along with G.I. Back Clampcomplete |
| 46 | SITC of 33KV GIF Clamp. |
| 47 | SITC of 33KV Pin Insulator 320CD (Polymer). |
| 48 | Supply & fixing ofG.INut, Bolt & Washers of different sizes as required. |
| 49 | SITCof 33 kVDanger Plate with back clamp made of25×3mm GIflat, (0.59Kg/mtr.) with bolting as required and complete. |
| 50 | SITCofAnticlimbing Device with back clamp 25×3mm flat, 0.59Kg/mtr. flat of 0.510mtr length 4nos=(4×0.59×0.510) and GI barbed wire 3KG per each. |
| 51 | SITC of No.6/8 GI Wire for road cross guarding 2nos. |
| 52 | SITC of 75×40×6mm Channel st cross arm 2.2mtr, @9.2Kg/mtr (4nos) with galvanization for road cross guarding. |
| 53 | SITC ofGI Pipe Earthing for 1no of road cross guarding 40 mm Dia medium Gauge 3 mtr Longincluding Material for earthing including brick masonry work for earth pit chamber (2\"×2\") etc.and RCC slab cover including salt, Charcoalcomplete as required and per technical specification and direction of E.I.C. |
| 54 | SITC of GI Flat (25×6)mm for earthing. |
| 55 | Sundries (Clamp, Connectors, Binding tape etc). |
| 56 | Dismantling. |
| 57 | Dismantling charges of HT Pole. |
| 58 | Dismantling charges of HT Line. |