Uttar Pradesh Jal Nigam-UPJN has published Surveying, Soil Investigation, Design And Supply Of All Materials, Labour, T&P Etc. Complete Required For Completion Of Following Works Of “Nagar Palika Parishad Kasganj Water Supply Scheme”:I) Construction Of Over Head Tank,Pump House, Boundary Wall With. Submission Date for this Tender is 30-04-2024. Tube Well Tenders in kasganj Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 11-Mar-2024 | CORRIGENDUM FOR DATE EXTENSION | Date | 02-04-2024 |
2 | 03-Apr-2024 | REVISE DATE AND TIME OF SUBMISSION OF E BID | Date | 15-04-2024 |
3 | 15-Apr-2024 | REVISED DATE AND TIME OF SUBMISSION OF BID | Date | 22-04-2024 |
4 | 22-Apr-2024 | REVISED DATE AND TIME OF BID SUBMISSION | Date | 30-04-2024 |
Sl. No. | Item Description |
1 | CIVIL WORKS |
2 | ESTIMATE FOR PUMP HOUSE IN ZONE |
3 | Provide all materials, labour, T&P etc. complete and construct Pump house size (3.6x3.0x3.0)m Chlorinating room size (1.8x1.2x3.0)m as per departmental type design and drawing (drawingno-D-2)andasperthe specificationsforcivilwork given in the bid document, including supply of all material, labour and T&P etc complete as per instructions of Engineer -in - charge. |
4 | Rebore tubewell platform and existing pump house plaster, painting & Pointing etc. completed. |
5 | Rising Main |
6 | Supply of ISI mark DI K-7/K-9 S&S pipes & specials (push on joints) of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality) including supply & fiing of specials with all statutory duties and taxes, third party inspection charges, transit insurance, freight, transportation to store / site of work, unloading. stacking etc. complete as directed by Engineer-in-charge. |
7 | 150mm dia D.I Class- k9 |
8 | 200mm dia D.I Class- k7 |
9 | 200mm dia D.I Class- k9 |
10 | 250mm dia D.I Class- k7 |
11 | Excavation Work |
12 | Excavation of earth in ordinary soil (loam, clay or sand) for pipe line and rising main trenches including lift upto 1.50 m and lead upto 50 m and refilling watering, ramming of the excavated earth into the trench and also disposal of surplus earth upto 50m from the center of the trenches including supply of all material labour, T&P etc complete as per instructions of Engineer -in -charge. |
13 | ordinary soil |
14 | Valve Chamber |
15 | Supply of following size of D.I.. D/F sluice valves as per I.S. 780-1960 tested to 10 Kg/Sq.m fixing in pipe line trenches, jointing and testing complete. |
16 | 150mm dia D.I Class- k9 |
17 | 200 MM dia D.I CLASS- K9 |
18 | 250 mm dia D.I Class- k9 |
19 | Supply of all materials, labour T&P and construct masonary type sluice valve chamber. |
20 | Carting, laying and jointing of the following sizes of pipes into the trenches including cost of all jointing materials, labour and T&P testing etc. complete. |
21 | 150mm dia D.I Class- k9 |
22 | 200mm dia D.I Class- k7 |
23 | 200mm dia D.I Class- k9 |
24 | 250mm dia D.I Class- k7 |
25 | Carting, laying and jointing of the following sizes of sluice valveinto the trenches including cost of all jointing materials, labour and T&P testing etc. complete. |
26 | 150mm dia D.I Class- k9 |
27 | 200mm dia D.I Class -k9 |
28 | 250mm dia D.I Class- k9 |
29 | Dismantling and reinstatement of following type of road surfaces for laying of pipe line including sorting out of serviceable material and disposal of unserviceable materials. |
30 | Dismantling of Interlocking Road |
31 | Reinstatment of Interlocking Road (with 40% new tiles and 60% used old tiles) |
32 | Dismantling of C.C. Road |
33 | Reinstatment of C.C. Road |
34 | Dismantling Bituminous surface |
35 | Reinstatement Bituminous surface |
36 | Dismantling of BOE Road |
37 | Reinstatement of BOE road |
38 | R.C.C Overhead Tank |
39 | Supply of all materials labour T&P etc. for complete construction of R.C.C. Over Head Tank of followingcapacityand staging min 0.6m above ground level with main components, soil testing and assuming bearingcapacity of soil as 8 MT, including cost of supply of design and drawings. All the water retaining components of OHT shall be casted in M-30 grade cement concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement, coarse sand and stone grit as per I.S. 11682 and I.S.456 Seismic effects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure and including 1M wide RCC doglegged staircase with separate coloumns, 1 m wide R.C.C. M30 balcony, M.S. ladder made of 50x50x6 mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, One aluminum ladder inside the tank from top dome to bottom dome, R.C.C. railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, Proper ventilator at top dome in circular shape of 1.2 m dia,Ultra Sonic Water level indicator fabricated with sensor connecting to automation, Lightening conductor as per I.S.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966, C.I. manhole of min 60x60cm size with locking arrangement, Supply, fixing, jointing of D.I.D/F Pipes of appropriate size with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet(300mm), outlet(300mm), overflow and washout as per latest / relevant I.S. specifications withall jointing materials for proper completion of work, Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit , Constructionof washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing, Supply of 200 mm dia PVC pipe as per I.S.- 4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound, Painting of all concrete surface and steel pipe works with three coats. |
40 | 1200 Kl /18M Staging |
41 | 1200 Kl /16M Staging |
42 | 1100 Kl /20M Staging |
43 | Testing Bearing Capicity of soil. |
44 | Repairing of 750 kl /19 m staging over head tank |
45 | Repairing of 2100 kl cwr cum pump house |
46 | Distribution System |
47 | Supply of High Density Polyethylene Pipes & electro-fusion specials (HDPE (PN-6)/PE-100), confirming to IS 4984 / 14151 / 12786 / 13488 (and other related I.S. codes) in coils / standard lengths with necessary jointing material like electro-fusioncoupler for Joints/Junctions , flanged joint, including all statutory duties and taxes, third party inspection charges, transit insurance, freight, transportation to store / site of work, unloading & stacking the same in covered shade duly protecting from sunrays & rains etc. complete as directed by Engineer-in-charge. |
48 | HDPE PIPE PE-100, PN-6 |
49 | 90 mm dia |
50 | 110 mm dia |
51 | 125 mm dia |
52 | 140 mm dia |
53 | 160 mm dia |
54 | D.I. K-7 Pipe |
55 | 200 mm dia |
56 | 250 mm dia |
57 | 300 mm dia |
58 | 350 mm dia |
59 | 400 mm dia |
60 | Carting laying and jointing of the following sizes of pipes into the trenches including cost of all jointing materials, labour and T&P testing etc. complete. |
61 | HDPE PIPE PE-100, PN-6 |
62 | 90 mm dia |
63 | 110 mm dia |
64 | 125 mm dia |
65 | 140 mm dia |
66 | 160 mm dia |
67 | D.I. K-7 Pipe |
68 | 200 mm dia |
69 | 250 mm dia |
70 | 300 mm dia |
71 | 350 mm dia |
72 | 400 mm dia |
73 | Distribution System - Pipeline Excavation |
74 | Distribution System - Connections |
75 | Provision for Single Tap making ferrule house connection in 90 to 160 mm dia distribution main with fixing of saddle pieces, connection fittings, GM ferrule of 15mm dia including brass tape with welded, 20mm dia (OD) HDPE pipe (12.5 kg/cm2) and 20 mm dia (OD) G.I. pipe class B upto house holder also including excavation of trenches, supply of all fittings maerials, labour, T&P etc. all work complete but excluding dismantling and reinstatement of all type roads as per direction of engineer incharge. |
76 | House service connections |
77 | For 90mmto 110mm dia |
78 | For 125mm to 160mm dia |
79 | For 180mm to 250mm dia |
80 | For 300mm dia |
81 | For 350mm to 500mm dia |
82 | Sluice valve chamber (masonry Type) - dia upto 200 mm - 1000 (L) x 1200 (W) x 1300 (H) mm |
83 | Sluice valve chamber (surface box Type) |
84 | Sluice valve chamber (surface box Type) - Fire Hydrantchamber (750 (L) X 450 (W) X 1000 (H) mm) |
85 | Air Valve Chamber 350 (L) x 350 (W) x 500 (H) mm |
86 | D.I.. D/F Sluice/Scour valves as per I.S. 780 suitable for a working pressure of 10 Kg/Sqm. |
87 | Sluice valve - 350 mm dia |
88 | Sluice valve - 300 mm dia |
89 | Sluice valve - 250 mm dia |
90 | Sluice valve - 200 mm dia |
91 | Sluice valve - 150 mm dia |
92 | Sluice valve - 125 mm dia |
93 | Sluice valve - 100 mm dia |
94 | Sluice valve - 80 mm dia |
95 | Scour Valve |
96 | Scour valve - 80 mm dia |
97 | Air valve 20 mm dia |
98 | Carting from store to site of work, lowering, fixing and jointing of following fittings in trenches. |
99 | D.I. Sluice valve |
100 | Sluice valve - 350 mm dia |
101 | Sluice valve - 300 mm dia |
102 | Sluice valve - 250 mm dia |
103 | Sluice valve - 200 mm dia |
104 | Sluice valve - 150 mm dia |
105 | Sluice valve - 125 mm dia |
106 | Sluice valve - 100 mm dia |
107 | Sluice valve - 80 mm dia |
108 | Scour Valve |
109 | Scour valve - 80 mm dia |
110 | Air valve 20 mm dia |
111 | Construction of 1.5 m high and 230 mm thick boundary wall with 300 mmx300 mm thick pillar made in Brick masonry in 1 cement and 4coarse sand mortar, the spacing between two pillar should not be more than 3.5m c/c and the depth of foundation should not be less than 0.60m, at the site of water works as per departmental type design and drawing, and, as per specifications given in the bid document including supply of all materials, labour T&P etc.for proper completion of work as per instructions of Engineer -in - charge. (Drawing No.D-1) |
112 | Boundary Wall (for Campus Area) |
113 | Supply and fixing of 3.6 m x 1.20 m MS gate including fabrication and supply of steel and construction of bounary wall pillars of size 1.35mx0.23mx0.23m with ornamental brick work 115mm th. around RCC, as per departmental type design and drawing (Drawing No. D-1) and as per specifications laid down in the bid document, including supply of all material,labour,T&P etc.required for proper completion of work as per instructions of Engineer-in-charge. |
114 | MS Gate |
115 | ConstructionofInterlockingpavementforapproachtowater works, as per departmental type design and drawing and as per specifications laid down in the bid document, including supply of all materials , labour, T&P etc.required for proper completion of work as per instructions of Engineer -in -charge. |
116 | Inter Locking Pavement for Approach Road |
117 | Drain for campus |
118 | Construction of LCS ROOM |
119 | Provide all materials labour, T&P etc. and construct single room staff quarter / office room at water works site identified by the Engineer-in-charge as per department type design and drawing and specifications of civil works laid down in the bid document, includingallmaterial labour,T&Petccompleteforproper completion of work as per instructions of Engineer -in -charge. (Drawing No.D-7) Extra depth for Site conditions to be added |
120 | STAFF QUARTER |
121 | E&M WORKS |
122 | Construction ofTW No 1 (Rebore) of Zone 1C |
123 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
124 | Transportation, Erection and Dismantling of Rig Machine |
125 | Drilling by RC/DC Rig Machine 600 mm dia |
126 | 0 to 65 mtr. deep |
127 | 65 to 100 mtr. deep 500 mm dia |
128 | 100 to 130 mtr. 500 mm dia |
129 | Tubewell Assembly |
130 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support girder etc. As required & as per typed design complete in all respect. |
131 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
132 | 200 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
133 | Supply of pea gravel |
134 | Logging of bore hole by departmental / approved electric logger |
135 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
136 | Lowering of 300mm dia pipe from GL to 60m deep BGL. |
137 | Lowering of 200mm dia pipe from 60 to 100m deep BGL. |
138 | Lowering of 200mm dia pipe from 100 to 120m deep BGL. |
139 | Development of Tubewell by compressor |
140 | Transportation, Installation and Dismantling of 250 PSI Compressor |
141 | Development of Tubewell by Adequate Capacity Air compressor |
142 | Development of Tubewell by O.P. Unit |
143 | Transportation, Installation and Dismantling of3 Cusec O.P. Unit & Yield Test. |
144 | Development of Tubewell by Adequate Capacity by O.P. Unit |
145 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab |
146 | Baricading/ fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident. |
147 | PUMPING PLANTfor Zone-1C, Tw No-1(Rebore)& TW No- 2(Existing) |
148 | For TW No 1 (Rebore) |
149 | SITC of Submersible pump setof Discharge1200 lpm at 57m head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items). (Head, discharge & HP are tantitive may vary as per site condition) |
150 | 25 H.P. or above as per site condition. |
151 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) |
152 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
153 | 4 x 16 sq. mm Al. cable |
154 | Automatic chlorination system compactable to SCADA system |
155 | Soft starter with RS-485 port-400V Classminimum 22 Kw rating or above as per site condition |
156 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) or above as per site condition |
157 | Motor operated actuator with sluice valve 150mm Sluice Valve |
158 | CE & UL certified Inteligent Smart Energy Meter |
159 | CE & UL certified Electro magnatice flow Meter 150mm size |
160 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
161 | CE & UL certified pressure transmitter |
162 | CE & UL certified Surge protector 3 phase at main switch. |
163 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
164 | Installation, commissioning & testing for one tubewell / OHT |
165 | For Tw No 2 (Existing) |
166 | SITC of Submersible pump set of Discharge 1100 lpm at 58 m Head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset,Servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).(Head, discharge & HP are tantitive may vary as per site condition) |
167 | 25 H.P. or above as per site condition. |
168 | 3 Mtr. long heavy duty size 150 mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) |
169 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
170 | 4 x 16 sq. mm Al. cable |
171 | Automatic chlorination system compactable to SCADA system |
172 | Soft starter with RS-485 port-400V Class minimum 22 Kw rating or above as per site condition |
173 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) or above as per site condition |
174 | Motor operated actuator with sluice valve 150 mm Sluice Valve |
175 | CE & UL certified Inteligent Smart Energy Meter |
176 | CE & UL certified Electro magnatice flow Meter 150mm size |
177 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
178 | CE & UL certified pressure transmitter |
179 | CE & UL certified Surge protector 3 phase at main switch. |
180 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
181 | Installation, commissioning & testing for one tubewell / OHT |
182 | SCADA Automation of PUMPING PLANTat Zone-01C, TW No-1(Rebore) & T.W. No 2 (Existing) |
183 | SCADA Automation Items |
184 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations (1x2) |
185 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges (1x2) |
186 | CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. (1x2) |
187 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) (1x2) |
188 | Trial run for 03 months period for each tubewell through SCADA (1x2) |
189 | TRIAL &RUN of Pumping Plant of Tw 1(Rebore)& 2(Existing) of Zone 1C |
190 | 03 Month operation & maintenance includingStaff & chlorine. |
191 | Construction of TW No 1 & 3 of Zone-1 D |
192 | Drilling of borehole for Tubewell contruction by RC/DC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
193 | Transportation, Erection and Dismantling of Rig Machine |
194 | Drilling by RC/DC Rig Machine 600 mm dia |
195 | 0 to 65 mtr. deep (65x2) |
196 | 65 to 100 mtr. deep 500 mm dia (35x2) |
197 | 100 to 130 mtr. 500 mm dia (30x2) |
198 | Tubewell Assembly |
199 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support girder etc. As required & as per typed design complete in all respect. |
200 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. (60.5x2) |
201 | 200 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. (60x2) |
202 | Supply of pea gravel (38.22x2) |
203 | Logging of bore hole by departmental / approved electric logger. |
204 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
205 | Lowering of 300mm dia pipe from GL to 60m deep BGL. (60x2) |
206 | Lowering of 200mm dia pipe from 60 to 100m deep BGL. (60x2) |
207 | Lowering of 200mm dia pipe from 100 to 120m deep BGL. (20x2) |
208 | Development of Tubewell by compressor |
209 | Transportation, Installation and Dismantling of 250 PSI Compressor (1x2) |
210 | Development of Tubewell by Adequate Capacity Air compressor (40x2) |
211 | Development of Tubewell by O.P. Unit |
212 | Transportation, Installation and Dismantling of3 Cusec O.P. Unit & Yield Test. (1x2) |
213 | Development of Tubewell by Adequate Capacity by O.P. Unit (80x2) |
214 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. (1x2) Note- it done by department. |
215 | Baricading/ fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident. (1x2) |
216 | PUMPING PLANTfor Zone-1D |
217 | For TW No 1 & 3 |
218 | SITC of Submersible pump set of Discharge 1200 lpm at 35 m head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).(Head, Discharge & HP are tantative may vary as per site condition) |
219 | 15 H.P. or above as per site condititon (1x2) |
220 | 3 Mtr. long heavy duty size 150 mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) (2x2) |
221 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. (36x2) |
222 | 4 x 16 sq. mm Al. cable (50x2) |
223 | Automatic chlorination system compactable to SCADA system (1x2) |
224 | Soft starter with RS-485 port-400V Class minimum15 Kw rating or above as per site condition (1x2) |
225 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) or above as per site condition (1x2) |
226 | Motor operated actuator with sluice valve 150mm Sluice Valve(2x2) |
227 | CE & UL certified Inteligent Smart Energy Meter (1x2) |
228 | CE & UL certified Electro magnatice flow Meter 150 mm size (1x2) |
229 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. (1x2) |
230 | CE & UL certified pressure transmitter (1x2) |
231 | CE & UL certified Surge protector 3 phase at main switch(1x2) |
232 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT(1x2) |
233 | Installation, commissioning & testing for one tubewell / OHT (1x2) |
234 | For TW No 2 (Existing) |
235 | SITC of Submersible pump set of Discharge 1000 lpm at 35 m head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items). (head , discharge & HP are tantative may vary as per site condition) |
236 | 12.5 H.P. or above as per site condition |
237 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) |
238 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
239 | 4 x 16 sq. mm Al. cable |
240 | Automatic chlorination system compactable to SCADA system |
241 | Soft starter with RS-485 port-400V Class minimum15 Kw rating or above as per site condition |
242 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.)or above as per site condition |
243 | Motor operated actuator with sluice valve 150mm Sluice Valve |
244 | CE & UL certified Inteligent Smart Energy Meter |
245 | CE & UL certified Electro magnatice flow Meter 150mm size |
246 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
247 | CE & UL certified pressure transmitter |
248 | CE & UL certified Surge protector 3 phase at main switch. |
249 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
250 | Installation, commissioning & testing for one tubewell / OHT |
251 | CWR of Zone 1D |
252 | Pump :- SupplyofHorizontal pump set with pump fitted with gland packing, MS fabricated base frame for both Motor & Pump, CI coupling (Spacer type), Steel coupling gurad.MOC: casing - Cast Iron FG 260, impeller - ASTMA A 743 Gr. CF8M, Shaft - AISI 410 a) Discharge : 1800 lpm x 27 m. head Electric Motor : - Supply of 4 Pole, 415 Volt, 50 Hz, 1450 RPM B3 mounting as per IE3 Standerd TEFC Motor. The motor shall besuitable to drivetheabove pumps within its whole range andof required capacity. 20 H.P.(head , discharge & HP are tantative may vary as per site condition) |
253 | Starter :- Supplyof SCADA Compacatable Motor soft starter suitable tooperateat0.415KV+10%3 phase, 50Hz. A.C.supply andtocontroltheabove motors. It shallcompriseofall protection devicesas per latest I.S.S. specifications. - 20 H.P. or above as per site condition - (3 Nos) L.T. Switchgear Panel Board :- Supply of 1 no. panelextensible typeswitchboard suitable for 0.415 KV3 phase 50 HZ. A.C. supply in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size forrequiredload. The switch board shall consist of the following : (a) 02no.Incoming Panelcomprisingofsuitable capacity ACB/MCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 03 nos. of above required motor. (b) 6 Nos. outgoing panelsfor pumping plants. 3 Nos. Of Pump, 01 No. for Internal & External lighting, 01 no. for welding & other miscellanious work and 01 nos spare Each panelhavingsuitable capacity MCCB with ammeter and C.T.with selectorswitch,KWmeter, single phasingpreventer, capacitoretc for proper functioning for whole E&M Equipments installed in scope ofCWR. |
254 | Servo-Stablizer 60 KVA or above as per site condition |
255 | Power Cable :- Supply and laying of1100 V grade 3 core 16 mm2 from panel to starter and starter to motor XLPE armoured cables ofrequiredsizes with earthing material (3x30 mt) approx. |
256 | C.I. / M.S. Fitting of Delivery pipes and specials as per details given below: 150 mm size individual delivery and 250 mm size common delivery with jointing material, Tee, bends |
257 | Reflux Valve 150 mm |
258 | Sluice Valve 250 mm with actuator |
259 | Sluice Valve 150 mm with actuator |
260 | Dismantling Joint. |
261 | 150 mm |
262 | 250 mm |
263 | Nut Bolts and rubber packing etc. |
264 | Supply of MS Girder for pump base etc. |
265 | Supply of spare parts required for maintenance of all equipments. |
266 | Direct on line type electromagnetic type flow meter of size 250 mm in common delivery ofM.S.pipelinefor measuring dischargeofpumpswithsignal transmitter device. Digitalflowindicatorshallbe installedin pump house on instrument control panel. |
267 | Supply of SCADA CompacatableElectronic level indicator. |
268 | Supply of electronic pressure Indicating devices SCADA Compactable. |
269 | Tools & spanners : HT, LT megger, Tong tester, Crimping tool (manual and hydraullic) |
270 | E.O.T. crane of 3 Tones capacity with 6 meter lift alongwith traveling trolley and girder etc. |
271 | SCADA Compatable Chlorination System |
272 | Erection and commissioning of above items. |
273 | Testing : At works of pumps & other equipments |
274 | Trial run and operation of pumping plants for one months. |
275 | Painting of equipments with two coats. |
276 | CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents. |
277 | Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch withinbuilt time delay & enclosure of SuitableAmpere rating (Confirming to I.E.C. - 60947-1 and I.E.C.- 60947-6-1)as specified in tender technical specification sheet |
278 | CE / UL approved manufacturer’s Radartype Level Transmitter for CWR as specified in tender technical specification sheet |
279 | CE / UL approved manufacturer’s Pressure Transmitterin each pumping delivery line as well main header line of Pump as per specifications specified in tender technical specification sheet. |
280 | Complete cabling for ZPS including all power and control cable of all equipments at ZPS and OHTs. |
281 | 02 nos(1W+1S) monoblock /submersible single phase 50 hz 3hp pumpset capable of drain out waste water of dry well with starter and all fittings arrangemnent (pipe,tee bend etc) required for complete disposal of waste water as required |
282 | Security Surveillance IP Camera with Recorer |
283 | Trial Run of CWR through SCADA for 3 Month |
284 | Internal & External Electrification of CWR Zone 1D (Lighting of bulding and campus) |
285 | Supply,installation and fixing of |
286 | M.S tubler poles 9.5 m height |
287 | Twin tube light covered |
288 | 450 mm dia exhaust fan |
289 | 1200 mm ceiling fan |
290 | 250 watt flood light |
291 | 15 amp power plug point |
292 | 5 Amp power plug point |
293 | Supply of tube light LED etc. |
294 | Wiring of plant in copper conductor |
295 | Supply &laying of 4x 16 sq mm Copper conductor cable |
296 | SCADA Automation Items for Tubewells |
297 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations (3x1) |
298 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges(3x1) |
299 | CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.(3x1) |
300 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) (3x1) |
301 | Trial run for 03 months period for each tubewell through SCADA(3x1) |
302 | Automation of CWR |
303 | CE & UL approved manufacturer"s RTU/PLC suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specified for each tubewell & CWR to store and transmit data on GSM backbone. RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification sheet including Control panel with IP 54 protection industrial grade for all equipments (Separate for control (24 V) and power equipments) with CE / UL approved manufacturer’s Surge protector for Control Panel and CE / UL approved manufacturer’s 7" HMItouchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters as specified in tender technical specification sheet .(Suitable for 03 nos. CWR Motor.) |
304 | GSM/GPRS based wireless communicationmodem for RTU/PLC capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant as specified in tender technical specification sheet. |
305 | CE/UL surge protector 3 phase at main switch. |
306 | CE/UL Certified 7" HMI Touchscreen suitable to commuticate with PLC / RTU for loac display and control of process parameter. (Suitable to display data of all 03 motors) |
307 | Control Panel with IP54 protection Indsutrial grade for all equipmets seprate for control (24 Volt) and power equipment. (Suitable for all 03 motors) |
308 | Installation, Testing & Commissioning |
309 | Trail Run of CWR Zone 1D |
310 | 03 Month Trial Run of 03 nos Tw & CWR including staff & liquid chlorine. |
311 | Zone-1 E |
312 | Construction of Tubewell(300X200 size) TW No 2 (Rebore) & TW No 3 |
313 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
314 | Transportation, Erection and Dismantling of Rig Machine (1x2) |
315 | Drilling by RC/DC Rig Machine 600 mm dia |
316 | 0 to 65 mtr. deep (65x2) |
317 | 65 to 100 mtr. deep 500 mm dia(35x2) |
318 | 100 to 130 mtr. 500 mm dia(30x2) |
319 | Tubewell Assembly |
320 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support girder etc. As required & as per typed design complete in all respect. |
321 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.(60.5x2) |
322 | 200 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.(60x2) |
323 | Supply of pea gravel (38.22x2) |
324 | Logging of bore hole by departmental / approved electric logger.(1x2) |
325 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
326 | Lowering of 300mm dia pipe from GL to 60m deep BGL. (60x2) |
327 | Lowering of 200mm dia pipe from 60 to 100m deep BGL. (40x2) |
328 | Lowering of 200mm dia pipe from 100 to 120m deep BGL.(20x2) |
329 | Development of Tubewell by compressor |
330 | Transportation, Installation and Dismantling of 250/350 PSI Compressor (1x2) |
331 | Development of Tubewell by Adequate Capacity Air compressor (40x2) |
332 | Development of Tubewell by O.P. Unit |
333 | Transportation, Installation and Dismantling of3 Cusec O.P. Unit & Yield Test. |
334 | Development of Tubewell by Adequate Capacity by O.P. Unit |
335 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
336 | Baricading/ fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident. |
337 | Pumping Plant tw Equipment at Existing Tubewell Zone 1E,TW No 1 |
338 | Servo-Stablizer 40 KVA or above as per site condition |
339 | Automatic chlorination system compactable to SCADA system |
340 | Soft starter with RS-485 port-400V Class minimum 22 Kw rating or as per site condition |
341 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
342 | Motor operated actuator for Existing Sluice Valve (size as per site condition) |
343 | CE & UL certified Inteligent Smart Energy Meter |
344 | CE & UL certified Electro magnatice flow Meter 150mm size or as per site condition |
345 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
346 | CE & UL certified pressure transmitter |
347 | CE & UL certified Surge protector 3 phase at main switch. |
348 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
349 | Installation, commissioning & testing for one tubewell / OHT |
350 | Pumping Plant at Zone 1E,TW No 2(Rebore) |
351 | SITC of Submersible pump set of 1200 lpm at 55 m head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).( head, discharge & HP are tantative may vary as per site condition) |
352 | 25 H.P. or above as per site condition. |
353 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) |
354 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
355 | 4 x 16 sq. mm Al. cable |
356 | Automatic chlorination system compactable to SCADA system |
357 | Soft starter with RS-485 port-400V Class minimum 22 Kw rating or aboveor above as per site condition. |
358 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
359 | Motor operated actuator with sluice valve 150mm Sluice Valve |
360 | CE & UL certified Inteligent Smart Energy Meter |
361 | CE & UL certified Electro magnatice flow Meter 150mm size |
362 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
363 | CE & UL certified pressure transmitter |
364 | CE & UL certified Surge protector 3 phase at main switch. |
365 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
366 | Installation, commissioning & testing for one tubewell / OHT |
367 | Pumping Plant at Zone 1E,TW No 3 |
368 | SITC of Submersible pump set of 839 lpm at 55 m head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).( head, discharge & HP are tantative may vary as per site condition) |
369 | 17.5 H.P. or above as per site condition. |
370 | 3 Mtr. long heavy duty size 100mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) |
371 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
372 | 4 x 16 sq. mm Al. cable |
373 | Automatic chlorination system compactable to SCADA system |
374 | Soft starter with RS-485 port-400V Class minimum 15 Kw rating or above as per site condition. |
375 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) or above as per site condition. |
376 | Motor operated actuator with sluice valve 100mm Sluice Valve |
377 | CE & UL certified Inteligent Smart Energy Meter |
378 | CE & UL certified Electro magnatice flow Meter 100mm size |
379 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
380 | CE & UL certified pressure transmitter |
381 | CE & UL certified Surge protector 3 phase at main switch. |
382 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
383 | Installation, commissioning & testing for one tubewell / OHT |
384 | SCADA Automation of Zone 1E TW No 1 (Existing), T.W. No 2 (Rebore) & T.W. No 3 |
385 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations (1x3) |
386 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges(1x3) |
387 | CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.(1x3) |
388 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) (1x3) |
389 | Trial run for 03 months period for 03 nos of tubewell through SCADA(1x3) |
390 | Trial run of Zone 1E |
391 | 03 Month Trial run of tubewells of Zone 1E with staff at tw 2(Rebore)&3 and liquid chlorine consumption on all 03 tubewells. |
392 | Zone-3 |
393 | Construction of Tubewell of Zone 3 T.W. No 3 |
394 | Drilling of borehole for Tubewell contruction by RC/DC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
395 | Transportation, Erection and Dismantling of Rig Machine |
396 | Drilling by RC/DC Rig Machine 500 mm dia |
397 | 0 to 65 mtr. deep |
398 | 65 to 100 mtr. deep 450 mm dia |
399 | 100 to 130 mtr. 450 mm dia |
400 | Tubewell Assembly |
401 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support girder etc. As required & as per typed design complete in all respect. |
402 | 200 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
403 | 150 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
404 | Supply of pea gravel |
405 | Logging of bore hole by departmental / approved electric logger. |
406 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
407 | Lowering of 200mm dia pipe from GL to 60m deep BGL. |
408 | Lowering of 150mm dia pipe from 60 to 100m deep BGL. |
409 | Lowering of 150mm dia pipe from 100 to 150m deep BGL. |
410 | Development of Tubewell by compressor |
411 | Transportation, Installation and Dismantling of 250 PSI Compressor |
412 | Development of Tubewell by Adequate Capacity Air compressor |
413 | Development of Tubewell by O.P. Unit |
414 | Transportation, Installation and Dismantling of1 Cusec O.P. Unit & Yield Test. |
415 | Development of Tubewell by Adequate Capacity by O.P. Unit |
416 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
417 | Baricading/ fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident. |
418 | E/M equipmenton Existing Pumping Plant at Tubewell of Zone 3 TW No 1 & 2 |
419 | Servo-Stablizer minimum 40 KVA or above or as per site condition. (1x2) |
420 | Automatic chlorination system compactable to SCADA system (1x2) |
421 | Soft starter with RS-485 port-400V Class minimum 22 Kw rating or above as per site condition. |
422 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.)or above as per site condition. (1x2) |
423 | Motor operated actuator for Existing Sluice Valve (1x2) |
424 | CE & UL certified Inteligent Smart Energy Meter (1x2) |
425 | CE & UL certified Electro magnatice flow Meter 150mm size (1x2) |
426 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. (1x2) |
427 | CE & UL certified pressure transmitter(1x2) |
428 | CE & UL certified Surge protector 3 phase at main switch(1x2) |
429 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT(1x2) |
430 | Installation, commissioning & testing for one tubewell / OHT (1x2) |
431 | Pumping Plant at Zone 3 TW No 3 |
432 | SITC of Submersible pump set of 492 lpm,59 m head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).(Head, Discharge & HPare tantative may vary as per site condition ) |
433 | 12.5 H.P. or above as per site condition |
434 | 3 Mtr. long heavy duty size 100mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) |
435 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
436 | 4 x 16 sq. mm Al. cable |
437 | Automatic chlorination system compactable to SCADA system |
438 | Soft starter with RS-485 port-400V Class minimum 15 Kw rating or above |
439 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
440 | Motor operated actuator with sluice valve 100mm Sluice Valve |
441 | CE & UL certified Inteligent Smart Energy Meter |
442 | CE & UL certified Electro magnatice flow Meter 100mm size |
443 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
444 | CE & UL certified pressure transmitter |
445 | CE & UL certified Surge protector 3 phase at main switch. |
446 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
447 | Installation, commissioning & testing for one tubewell / OHT |
448 | SCADA Automation Items |
449 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations (1x3) |
450 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges(1x3) |
451 | CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. (1x3) |
452 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) (1x3) |
453 | Trial run for 03 months period for 03 nos of tubewell through SCADA(1x3) |
454 | Trial run of Zone 3 TW No 1 & 2 (Existing) & TW No 3 |
455 | 03 Month Trial run of tubewells of Zone 3 with staff at tw 3 and liquid chlorine consumption on all 03 tubewells. |
456 | Zone-4 |
457 | Construction of Tubewell of Zone 4 TW No 1 (Rebore) |
458 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
459 | Transportation, Erection and Dismantling of Rig Machine |
460 | Drilling by RC/DC Rig Machine 500 mm dia |
461 | 0 to 65 mtr. deep |
462 | 65 to 100 mtr. deep 450 mm dia |
463 | 100 to 130 mtr. 450 mm dia |
464 | Tubewell Assembly |
465 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. |
466 | 200 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
467 | 150 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
468 | Supply of pea gravel |
469 | Logging of bore hole by departmental / approved electric logger. |
470 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
471 | Lowering of 200mm dia pipe from GL to 60m deep BGL. |
472 | Lowering of 150mm dia pipe from 60 to 100m deep BGL. |
473 | Lowering of 150mm dia pipe from 100 to 150m deep BGL. |
474 | Development of Tubewell by compressor |
475 | Transportation, Installation and Dismantling of 250 PSI Compressor |
476 | Development of Tubewell by Adequate Capacity Air compressor |
477 | Development of Tubewell by O.P. Unit |
478 | Transportation, Installation and Dismantling of1 Cusec O.P. Unit & Yield Test. |
479 | Development of Tubewell by Adequate Capacity by O.P. Unit |
480 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
481 | Baricading/ fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident. |
482 | Pumping plant of Zone 4 TW No 1 (Rebore) |
483 | SITC of Submersible pump set of Discharge 600lpm ,59 m head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset,servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items). (Head, discharge & HP are tantative may vary as per site condition) |
484 | 15 H.P. or above as per site condition. |
485 | 3 Mtr. long heavy duty size 100mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) |
486 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
487 | 4 x 16 sq. mm Al. cable |
488 | Automatic chlorination system compactable to SCADA system |
489 | Soft starter with RS-485 port-400V Class minimum 22 Kw rating or above as per site condition. |
490 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
491 | Motor operated actuator with sluice valve 150mm Sluice Valve |
492 | CE & UL certified Inteligent Smart Energy Meter |
493 | CE & UL certified Electro magnatice flow Meter 150mm size |
494 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
495 | CE & UL certified pressure transmitter |
496 | CE & UL certified Surge protector 3 phase at main switch. |
497 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
498 | Installation, commissioning & testing for one tubewell / OHT |
499 | Pumping plant of Zone 4 TW No 2(Existing) |
500 | SITC of Submersible pump set of discharge 1100 lpm ,58 m head with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Servo Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).( head, discharge & HP are tantative may vary as per site condition) |
501 | 25 H.P. or above as per site condition. |
502 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above spare (for 18 mtr length ) (1 set = 02 nos) |
503 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
504 | 4 x 16 sq. mm Al. cable |
505 | Automatic chlorination system compactable to SCADA system |
506 | Soft starter with RS-485 port-400V Class minimum 22 Kw rating or above as per site condition. |
507 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
508 | Motor operated actuator with sluice valve 150mm Sluice Valve |
509 | CE & UL certified Inteligent Smart Energy Meter |
510 | CE & UL certified Electro magnatice flow Meter 150mm size |
511 | CE & UL certified hydro static type sub soil water level transmitter for tubewell. |
512 | CE & UL certified pressure transmitter |
513 | CE & UL certified Surge protector 3 phase at main switch. |
514 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
515 | Installation, commissioning & testing for one tubewell / OHT |
516 | SCADA Automation Items |
517 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations (1x2) |
518 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges(1x2) |
519 | CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.(1x2) |
520 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) (1x2) |
521 | Trial run for 03 months period for 02 nos of tubewell through SCADA (1x2) |
522 | Trial run of Zone 4 T.W No 1 (Rebore) & T.W. No 2 (existing) |
523 | 03 Month Trial run of tubewells of Zone 4 with staff at tw 1(Rebore) and liquid chlorine consumption on all 02 nos of tubewells. |
524 | OHT forZone-1C, 1D, 1E 3&4 |
525 | Motor operated actuator for Existing sluice valve onExisting OHTof 300 mm size. of Zone 1C |
526 | Motor operated actuatorwith sluice valve on New OHTof 400 mm size. Of Zone 1D, 1E & Zone 3 |
527 | Motor operated actuator for Existing sluice valve onExisting OHT of 250 mm size. of Zone 4 |
528 | Flow Meter on OHT delivery line of size 300 mm dia for Existing OHT of Zone 1C |
529 | Flow Meter on OHT delivery line of size 400 mm dia for New OHT of Zone 1D, 1E & Zone 3 |
530 | Flow Meter on OHT delivery line of size 250 mm dia for Existing OHT of Zone 4 |
531 | Chlorine Analyzer rnge 0-5 ppm (electrolyte with membrane cap; Type- Amperometric. |
532 | CE/UL certified Radar type Level Transmitter for Over haead Tank for Eisting OHT of zone 1&2 and new OHT of Zone 3 |
533 | MASTER CONTROL SYSTEM (MCS) |
534 | CE/UL & BIS Certifed industrial grade LED MONITOR with latest configuration |
535 | (i) 65" (upto 50 Tubewells). |
536 | Desktop/PC with i5/i7 processor for |
537 | CE/UL Certified 5KVA UPS with batteries . |
538 | Full development version of required TAGS SCADA Software with coustomization of sowftware for MCS as per requirement . |
539 | CE/UL Certified master control room PLC with redundant CPU & power supply at MCS in IP54 enclouser |
540 | CE/UL Certified Field gateway agent for transfering data from MCS to Central control room. |
541 | GSM based wireless/Broaband/Equipment communication system for PLC capable to transfer & received data & gather data from remote sites to control satation, All accessories included signal enhancer antenna along with running expences, till DLP. |
542 | CE/UL Certified Firewall for network protection. |
543 | SURGE PROTECTOR FOR ETHERNET communication protection. |
544 | CE/UL certified industrial grade Ethernet Switch. |
545 | Mobile App Facility system architecture (industries internet based & viewed through mobile apps for increased local & Remote Visibility). |
546 | Canon/HP or equivalent Laser Printer 1018 or equivement. |
547 | Security Sureillance IP camera with recorder (optional) |
548 | Installion, Commissioning & testing including required furniture, A/c etc. |
549 | Trial run of MCS for 03 months period |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy