Uttar Pradesh Housing And Development Board-UPAVP has published Tender For Internal Electrical/Mechanical Work In Proposed Building For Newly Operated Pharmacy Department At Campus Of Chaudhary Charan Singh University, Meerut.. Submission Date for this Tender is 18-03-2024. Mechanical engineering Service Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42843784
Tender For Internal Electrical/Mechanical Work In Proposed Building For Newly Operated Pharmacy Department At Campus Of Chaudhary Charan Singh University, Meerut.
Open Tender
Indian
Uttar Pradesh
meerut
18-03-2024

Tender Details

Internal Electrical / Mechanical Work In Proposed Building For Newly Operated Pharmacy Department At Campus Of Chaudhary Charan Singh University, Meerut.

Key Value

Document Fees
INR 5310 /-
EMD
INR 250000.0 /-
Tender Value
INR 1.11 Crore /-

BOQ Items

NAME WORK :INTERNAL ELECTRICAL/MECHANICAL WORK IN PROPOSED BUILDING FOR NEWLY OPERATED PHARMACY DEPARTMENT AT CAMPUS OFCHAUDHARY CHARAN SINGH UNIVERSITY, MEERUT.
Sl. No. Item Description
1Internal Electrical Work
2Wiring point for light with 1.5 Sq. mm FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. continuity wire, Modular type switch & ceiling rose/angle/ batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
3Wiring point for two way light with 1.5 Sq. mm F.R. PVC insulated multistrand single core copper conductor cable in PVC conduit Pipe with 1.5 Sqmm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit. Modular type switches & ceiling rose/angle /batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
4Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit, Modular type switch & ceiling rose on 3 mm. thick backelite sheet etc. complete in all respect with Modular Box & Cover plate.
5Wiring point for 5Amp. plug point with 1.5 Sq. mm F.R. PVC insulated multistrand single core copper conductor cable in PVC conduit Pipe with 1.5 Sqmm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit. Modular type switches & ceiling rose/angle /batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
6Wiring for circuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.
72 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire
82 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire
92 x 4 sq.mm. + 1 x 2.5 sq.mm. Earth wire
102 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire
114 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire
124 x 16 sq.mm. + 2 x 10 sq.mm. Earth wire
13Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.
14Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
15Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work.
16Supply and fixing of batten / angle holder complete in all respect.
17Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.
18Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated diecast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.
19S/F of LED tube light with batten suitable for up to 1x22 watt LED tube light complete including tube etc on surface complete in all respect.
20Supply and fixing hexagonal/Round G.P. fan box of approved make made up of 1.0 mm thick ISI Marked G.P. sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round Zink coated M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting along with supply of all material, labor, T&P etc. required for proper completion of the work
21S/F of 3mm thick bakelite sheet cover round/hexagonal Type for fan box complete with all material, Labour T&P as per direction of E/I.
22S/F of 3mm thickAl. Sheet junction box cover complete in all material labour T&p as per direction of E/I.
23Supply & Fixingof 1200 mm Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.
24Supply and erection of AC 300 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep. as per direction of E/I
25S & F sheet steel enclosure surface/Flush mounting fitted with 20Amp. 2Pin and earth metal clad scraping earth plug and socket complete in all respect. as directed at site by Engineer in charge.
26S & F surface/Flush mounting 4ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge.
27S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve
28S&F single pole MCB blanking plate.
29S&F of 40 Amp. 4 Pole. Isolator.
30S&F of 63 Amp. 4 Pole. Isolator.
31Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules.
32Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
33150 mm width X 50 mm depth X 1.6 mm thickness
34300 mm width X 50 mm depth X 1.6 mm thickness
35Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
36Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.
37Supply & Errecetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entries Electrical control panel with TPN MCCB"s (Four Pole 36 KA with thermal magnetic release) Switches Complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with detachable side covers and shall be suitable for extension on the sides. The MCCB"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.
38The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.
39Incomer : 630 Amp MCCB-1 No Outgoings : 200 Amp.MCCB- 1 No ,100 Amp MCCB-1 No & 63 Amp.MCCB-5 Nos
40Incomer : 400 Amp. MCCB-1 Nos Outgoings : 200 Amp. MCCB-1 No100 Amp MCCB-1 No & 63 Amp MCCB-2 Nos Cat. B. Pannel Cubicle Type
41Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
4210 Sqmm 4 Core
4335 Sq mm 3.5 Core
4450 Sq mm 3.5 Core
45150 Sq mm 3.5 Core
46240 Sq mm 3.5 Core
47Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge.
4810 Sqmm 4 Core
4935 Sq mm 3.5 Core
5050 Sq mm 3.5 Core
51150 Sq mm 3.5 Core
52240 Sq mm 3.5 Core
53Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the Engineer incharge.
5410 Sqmm
5516 Sq mm
5625 Sqmm
5735 Sq mm
5850 Sq mm
5970 Sq mm
60120 Sq mm
61150 Sq mm
62240 Sq mm
63Fire Fighting Work
64Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
65200 mm dia
66150 mm dia
67100 mm dia
6880 mm dia
6965mm dia
7050 mm dia
7132mm dia
7225 mm dia
73Providing laying, testing & commissioning of "C" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
74150 mm dia
75Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket
76Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required
77Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
78Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
79Providing and fixingHose Box (600x300x200)size of suitable size made out of 16/18 SWG thick having central opening and 4 mm thick glazed glass Double door including necessory rubber beading key pocket, handle locking arrengment painting with polyurethene based red paint etc. The words "FIRE HOSE" to be painted on the dooor as per approved drawing complete in all respect.
80Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
814 way - 150 mm dia M.S. Pipe
82Supply, fixing, testing and commissioning of 25mm Ball Valve complete.
83Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
84Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads2280 lpm at 70 m Head
85Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.Make :- Kirloskar/ other Standard make.DSR Nos 18.2.52280 lpm at 70 m Head
86Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) a) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS : 325. c) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. Make Kirloskar/other standard make DSR Nos 18.3.2 180 lpm at 70 m Head
87Supplying, installation, testing and commissioning of electric driven terrace pump suitable forutomatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head si no-18.4.2
88Automatic Control Panel(s) Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : INCOMING 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A Outgoings Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip ndicating lamps) Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
89Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
90Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.
91Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.
92150 mm dia
93100 mm dia
9480 mm dia
95Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required.
96150 mm dia
97100 mm dia
98Supply and fixingof C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completionof work.
99Supply and fixingof fire extinguisher,ABC Type 6.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completionof work.
100Supply and fixing of self glow type exit sinage.
101SITC ofSprinkler 68° deg, complete in all respects. (Make:- OMEX/ Life Guard/Safex)
102Pendent Type
103Fire Alarm SystemWork
104Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card,minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
105Two Loop Panel.
106Supplying, installation, testing & commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required.
107Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
108Supplying, installation, testing & commissioning of addressable phone control module complete as required.
109Supplying, installation, testing & commissioning of addressable manual call point complete as required.
110Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
111Supplying, installation, testing & commissioning of addressable fire control module complete as required.
112Supplying, installation, testing & commissioning of faultisolator complete with base as required.
113Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
114Supplying, installation, testing & commissioning of addressable phone control module complete as required
115Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
116Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
11716 Sqmm 4 Core
11850 Sqmm 3.5 Core
119120 Sqmm 3.5 Core
120Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge.
12116 Sqmm 4 Core
12250 Sqmm 3.5 Core
123120 Sqmm 3.5 Core
124Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the Engineer incharge.
12516 Sqmm
12625 Sqmm
12750 Sqmm
12870 Sqmm
129120 Sq mm
130Supplying, installation, testing & commissioning of 6 zone,voice alarm controller with USB, MP3 player (including 6 zonebutton paging station) with seamless integration facility withmain fire alarm panel for voice evacuation complete asrequired
131Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
132Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
133Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
134Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
135speaker cable Two pair, 2-core, 1.5 sqmm
136speaker cable Four pair, 2-core, 1.5 sqmm
137Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.
138Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
139Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
140150 mm width X 50 mm depth X 1.6 mm thickness
141300 mm width X 50 mm depth X 1.6 mm thickness
142Construction of under ground tank of 100000 Leter capacity and pump house complete in all respect.
143Earth work in excavation in trenches for foundationsand pipes cables etc in ordinary soil (loan clay or sand) including lift upto 1.5 m, leadupto 50 m anddressingof sidesand ramming of bottom anddisposal of surplusexcavated earth as directed by the Engineer- in- charge with in alead of 50m .(Including royalty).
144Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.From 1.5-3.0 meter.
145Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.From 3.0-4.5 meter.
146Providing and layingin cement concrete 1:4:8 (1 cement :4 coarse sand :8stone ballast 40 mm nominal size) and curing complete,including cost ofform- work,in foundation and floors.
147Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 345 mm thick.
148Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). SLAB.
1491:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)Raft foundation and footing.
150Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources).
151Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
15215 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width.
15312mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth as per the direction E/I. (1) 1 cement : 6 C. sand.
154Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm).
155Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. M.S. Grill. As per D.S.R. Nos-10.10
156Z-section steel window.
157Supply and fixingof flushdoors commercialqualityconformingtoI.S.2202 Part I (1983) includingfixingof woodencleats andstoppers and including fixing andadjustment of hinges, bolts,locks, handle, springs and other fittings with necessary screws completed. As per D.S.R. Nos-9.21.2
158Fabrication of M.S. Angle iron 40x40x5 mm. As per D.S.R. Nos-10.1
159Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer"s specifications including appropriatepriming coat, preparation of surface, etc. complete On steel work.
160Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.
161Providing and mixing water proofing material (Dr. fixet URP) in cement mortar for concrete work in proportion recommended by the manufacturer.
162Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
163Providing & fixing 75mm dia vent pipes.
164Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
165M.D. -10- Circular shape 500mm internal diamete.
Disclaimer :