}

Tender For Selection Of Implementation Agency Ia For Implementation Of Integrated Security And Traffic Management System Istms For Greater Noida City, noida-Uttar Pradesh

Greater Noida Industrial Development Authority-GNIDA has published Tender For Selection Of Implementation Agency Ia For Implementation Of Integrated Security And Traffic Management System Istms For Greater Noida City. Submission Date for this Tender is 30-04-2024. Spare Part Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42843512
Corrigendum : Tender For Selection Of Implementation Agency Ia For Implementation Of Integrated Security And Traffic Management System Istms For Greater Noida City
Open Tender
Indian
Uttar Pradesh
noida
30-04-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Selection Of Implementation Agency Ia For Implementation Of Integrated Security And Traffic Management System Istms For Greater Noida City- 1 Hardware - Field Components 2 Ip Outdoor 2Mp Ptz Camera, Min 30X Optical 10 X Digital Zoom ( Ip 66 Housing, 24Vac / Poe+, 128 Gb Sd Card, Surge Protection Devices, All Type Of Cables Mounting Bracket With Bird Spikes And All Required Accessories ) . 3 Ip Fixed 4Mp Hd Camera With Ip 66 Rated Housing For Outdoor Use, 128 Gb Sd Card, Surge Protection Devices, Mounting Bracket, Bird Spikes, All Type Of Cables With All Required Accessories 4 Galvanized Iron ( Gi ) Standard Poles For Surveillance Cameras And Pa System ( Minimum Height Of 6.5 Meters ) As Per Industrial Standards And Governmemnt Norms / Guidelines, 160Kmph Wind Speed Bearing Capacity, Load Bearing Capacity Of Minimum 15Kg With Foundation, Fasteners / Bolts, ( Complete In All Respects Including Rust Protection, Paint, Civil Work And Earthing, Structural Design And Material Composition Test Certificate ) As Per Solution Requirement 5 Ip Fixed Box 2Mp Hd Box Anpr Cameras With Ip 66 Rated Housing, 128 Gb Sd Card, Surge Protection Devices, Mounting Brackets, Bird Spikes, All Type Of Cables With All Required Accessories 6 Galvanized Iron ( Gi ) Double Arm Cantilever Poles At Traffic Junctions For Anpr Cameras And Ir Illuminators ( Minimum Height Of Pole 6.5 Meters ) As Per Industrial Standards And Governmemnt Norms / Guidelines, For Ground Clearance Of 6 Meters, 160Kmph Wind Speed Bearing Capacity, Load Bearing Capacity Of Minimum 15Kg With Foundation, Fasteners / Bolts, ( Complete In All Respects Including Rust Protection, Paint, Civil Work And Earthing, Structural Design And Material Composition Test Certificate ) As Per Solution Requirement 7 Ip Fixed 2Mp Hd Rlvd Camera With Ip 66 Rated Housing For Outdoor Use, 128 Gb Sd Card, Surge Protection Devices, Mounting Bracket, Bird Spikes, All Type Of Cables With All Required Accessories 8 External Ir Illuminators For Anpr Cameras With All Type Of Cables And All Required Accessories. Min. 80 Meters Or Better, Adjustable Angle To Cover The Complete Field Of View At Specified Locations For Higher Accuracy In Performance. Power 70 – 100 W 9 Industrial Lpu With Minimum Intel I7 Processor, 13Th Generation Or Better For Anpr, Rlvd, Svd & Traffic Applications And Video Analytics ( 15 Days Ssd Storage ) With All Type Of Cables And All Required Accessories 10 Speed Detection Device ( 4 Lane ) Capable To Detectspeed More Than 200 Kmph, Complete In All Aspectincluding 4D Radar, Anpr ( Global Shutter ) Camera, 128 Gb Sd Card, Surge Protection Devices, Mcb, Earthing, Ir Illuminator, Speed Licenses, Mounting Structure, Field Switch, All Type Of Cables Etc. And All Required Accessories ) As Per Solution Requirement 11 Speed Detection Device ( 6 Lane ) For More Than 200 Kmph, Complete In All Aspectincluding 4D Radar, Anpr ( Global Shutter ) Camera, 128 Gb Sd Card, Surge Protection Devices, Mcb, Earthing, Ir Illuminator, Speed Licenses, Mounting Structure, Field Switch, All Type Of All Type Of Cables And All Required Accessories ) As Per Solution Requirement 12 Adaptive Traffic Control System ( Atcs ) Traffic Light Controllers With 24Cycle Plan , Mininum 20 Cycle Switch Per Day Junction Box And All Controller Modules And Accessories. All Type Of All Type Of Cables, And All Required Accessories As Per Solution Requirement 13 Optical / Thermal Video-Based Vehicle Detector Devices For General Surveillance And Evidence / Rlvd Image Capturing. The Vtds System At Any Point Of Time, Shall Provide A Minimum Of 3 Classification Levels Viz. 2-Wheeler, 3-Wheeler / Autorickshaws, E-Rikshaw, Scv, Lmv, Hmv At Any Given Point In Time. All Type Of All Type Of Cables, And All Required Accessories As Per Solution Requirement 14 Traffic Light Aspects - Operating Voltage Voltage Of - 12 / 24 Dc / 230Vac, Narrow Beam Type With Clear Lens & Luminance Uniformity, Ip65, Convex Tinted Lens / Water Clear Lens, Fuse And Transients Shall Be Available, Turn Off / Turn On Time: 100 Milli Seconds Max, Minimum Luminous Intensity ( Measured At Intensity Point ) ( Cd ) : Red 400, Amber 400, Green 400, Protection For Current Voltages Spikes For All The Below Mentioned Colours Of Traffic Light Aspects, With All Required Accessories As Per Solution Requirement ( A15 To A19 ) 15 Traffic Signal Aspects - Red 16 Traffic Signal Aspects - Amber 17 Traffic Signal Aspects - Green Arrow 18 Traffic Signal Aspects - Pedestrian Red 19 Traffic Signal Aspects - Pedestrian Green 20 Galvanized Iron ( Gi ) Single Arm Cantilever Poles For ( Minimum Height Of 6.5 Meters ) As Per Industrial Standards And Governmemnt Norms / Guidelines, For Ground Clearance Of 6.5 Meters, 160Kmph Wind Speed Bearing Capacity, Load Bearing Capacity Of Minimum 25Kg For Traffic Light Aspects, Speed Detection Devices ( 4D Radar ) , Anpr Cameras And Ir Illuminators With Foundation, Fasteners / Bolts, ( Complete In All Respects Including Rust Protection, Paint, Civil Work And Earthing, Structural Design And Material Composition Test Certificate ) As Per Solution Requirement 21 Galvanized Iron ( Gi ) Standard Poles ( Minimum Height Of 4 Meters ) As Per Industrial Standards And Governmemnt Norms / Guidelines, 160Kmph Wind Speed Bearing Capacity, Load Bearing Capacity Of Minimum 25Kg For Traffic Light Aspects With Foundation, Fasteners / Bolts, ( Complete In All Respects Including Rust Protection, Paint, Civil Work And Earthing, Structural Design And Material Composition Test Certificate ) As Per Solution Requirement 22 Vehicular Adaptive Countdown Timer ( Acdt ) For Atcs Junctions, 300Mm ( Min ) , Dual Colored ( Red & Green ) , 12 / 24V Dc Or 230V Ac ~ 50Hz, Viewing Angle Minimum 23° To 30° , Ip 65, Shall Be Able To Dynamically Show Timings By Direct Interfacing From The Controller, With All Required Accessories As Per Solution Requirement 23 Pedestrian Count Down Timer For Atcs Junctions, 300Mm ( Min ) , Dual Colored ( Red & Green ) , 12 / 24V Dc Or 230V Ac ~ 50Hz, Viewing Angle Minimum 23° To 30° , Ip 65, Shall Be Able To Dynamically Show Timings By Direct Interfacing From The Controller, With All Required Accessories As Per Solution Requirement 24 Outdoor Variable Message Signboards / Displays Minimum Size 2.8 M X 1.9M , Pixel Pitch 7 Mm Or Better, Min 22000 Pixels Per Sqm Or Higher, Brightness- 5500 Cd / M² Or Better, Power Consumption - 850 W / Sqm Or Lower, 100 ~ 240 Vac Power Input, Front Ip65 / Rear Ip54 Complete In All Respects, Including Mcb, 1.5Kva Ups For 30 Min.S Backup, Surge Protection Devices, All Type Of Cables, Earthing, Etc. With All Required Accessories As Per Solution Requirement As Per Solution Requirement. 25 Mounting Structure For Variable Message Signboard / Display, Considering Height Clearance As Per Government Guidelines, 160Km / Hour Wind Speed Bearing Capacity, Withfoundation, Fasteners / Bolts ( Complete In All Respects Including Paint, Civil Work And Earthing, Structural Design And Material Composition Test Certificate ) As Per Solution Requirement Suitable For Above Mentioned Variable Messaging Signboard ( Size 2.8 X 1.9 Mtrs ) 26 Outdoor Variable Message Signboards / Displays Minimum Size 3.8 M X 1.9M , Pixel Pitch 7 Mm Or Better, Min 22000 Pixels Per Sqm Or Higher, Brightness- 5500 Cd / M² Or Better, Power Consumption - 850 W / Sqm Or Lower, 100 ~ 240 Vac Power Input, Front Ip65 / Rear Ip54 Complete In All Respects, Including Mcb, 1.5 Kva Ups For 30 Min.S Backup, Surge Protection Devices, Cables, Earthing, Field Switch, Junction Box Etc. As Per Solution Requirement 27 Mounting Structure For Variable Message Signboards / Displays, Considering Height Clearance As Per Government Guidelines, 160Km / Hour Wind Speed Bearing Capacity, Withfoundation, Fasteners / Bolts ( Complete In All Respects Including Paint, Civil Work And Earthing, Structural Design And Material Composition Test Certificate ) As Per Solution Requirement Suitable For Above Mentioned Variable Messaging Signboard ( Size 3.8 X 1.9 Mtrs ) 28 Pa System For Public Announcement System For Outdoor Use, Minimum 4 Speakers At Each Location With 30 W Capacity Each, 50Hz To 15000 Hz For Amplifier, Ip Amplifier With Minimum 250 Watts, Class D. Redundant Power Supply Provision Inbuilt In Amplifier, Main Power Supply: 100 – 240 Vac, With Central Software Based Server Application Capable Of Working With 100% Redundancy 29 Emergency Call Box ( Ecb ) , Ethernet Connectivity, Ip66 / Ip65, Ik09 Protection, Speaking Distance Minimum 5 Ft, Inbuilt Amplifier, Minimum 3 Inputs Ad 2 Output Relay Contacts, Call Button: Watertight, Push Button, Visual Feedback For Button Press And Call Indication With Acoustic Hood To Filter Background Noise With Its Application-Two Way Communication 30 Galvanized Iron ( Gi ) Standard Pole For Ecb ( Minimum Height Of 2.5 Meters ) As Per Industrial Standards And Governmemnt Norms / Guidelines, 160Kmph Wind Speed Bearing Capacity, Load Bearing Capacity Of Minimum 25Kgwith Foundation, Fasteners / Bolts, ( Complete In All Respects Including Rust Protection, Paint, Civil Work And Earthing, Structural Design And Material Composition Test Certificate ) As Per Solution Requirement 31 Ground Mountable Main Junction Box Ip 55 Outdoor. Thickness Ranges Minimum 1.5Mm, 15U Rack With Load Bearing Capacity Of 40Kg Or More And One-Fold Door Type. 3 Point High Quality Locking System Withcompression Manual Lock To Accomodate Power Supply, Ups, Network Switch Other Field Equipment With Earthing. 32 Pole Mountable Distribution Junction Box Ip 55 Outdoor, Thickness Ranges Minimum 1.2Mm, One-Fold Door Type. 3 Point High Quality Locking System Withcompression Manual Lock To Accomodate Lpu, Switches Etc. With Earthing. 33 Online Ups, Pure Sine Wave Igbt Based Pwm Technology, Output Voltage 208 / 200 / 220Vac / 230Vac. Bis Standard, Ce Certified, Rohs Certified, Govt. Of India Epr ( E-Waste ) Certification. There Shall Be Min 3 Nos 6 Amp With Indian Sockets With 1 Kva Load Rating To Provide 1 Hour Power Backup To All The Connected Devices With Surge Protection, Earthing And Required Accessories. 34 Online Ups, Pure Sine Wave Igbt Based Pwm Technology, Output Voltage 208 / 200 / 220Vac / 230Vac. Bis Standard, Ce Certified, Rohs Certified, Govt. Of India Epr ( E-Waste ) Certification. There Shall Be Min 3 Nos 6 Amp With Indian Sockets With 1.5 Kva Load Rating To Provide 1 Hour Power Backup To All The Connected Devices With Surge Protection, Earthing And Required Accessories. 35 Online Ups, Pure Sine Wave Igbt Based Pwm Technology, Output Voltage 208 / 200 / 220Vac / 230Vac. Bis Standard, Ce Certified, Rohs Certified, Govt. Of India Epr ( E-Waste ) Certification. There Shall Be Min 3 Nos 6 Amp With Indian Sockets With 2 Kva Load Rating To Provide 1 Hour Power Backup To All The Connected Devices With Surge Protection, Earthing And Required Accessories. 36 Edge Level ( Field ) 24 Port ( Poe ) Industrial Grade Managed Network Switch With Power Supply, 20 X 10M / 100M / 1G Rj45 Poe Port , 4 X 100M / 1G Sfp Port , 1 X Rj45console Port, Sfp And Other Accessories At Each Main Junction Boxas Per Solution Requirement 37 Edge Level ( Field ) 16 Port ( Poe ) Industrial Grade Managed Network Switch With Power Supply, 16 X 10M / 100M / 1G Rj45 Poe Port , 2 X 100M / 1G Sfp , 1 X Rj45 Console Port, Sfp And Other Accessories At Each Main Junction Boxas Per Solution Requirement 38 Edge Level ( Field ) 8 Port ( Poe ) Industrial Grade Managed Network Switch With Power Supply, 8 X 10 / 100 / 1000Base-T Ports Poe + 4 X 1G Sfp Slot + 1 Console Ports, Sfp And Other Accessories At Each Main Junction Boxas Per Solution Requirement 39 Edge Level ( Field ) 4 Port ( Poe ) Industrial Grade Managed Network Switch With Power Supply, 4 X 10 / 100 / 1000Base-T Ports Poe + 4 Sfp Slots + 1 Console Port, Sfp And Other Accessories At Each Main Junction Boxas Per Solution Requirement 40 Cautionary, Warning And Informatory Road Signages ( Like U-Turn Prohibited, Roundabout, Speed Limit, No Parking, Traffic Signal Ahead, Pedestrian Crossing, Under Surveillance Etc. ) -Shape: Circular / Triangular / Square, Background: White, Border: Redsymbol / Letter: As Per Government Guidelines, Complete With Civil Work With 3 Mtrs Of Gi Standard Pole, Wind Bearing Capacity Of 160Kmph, Load Bearing Capacity Of 5Kg, Complete With Rust Protection, Paint, Fixtures In All Respects 41 Workstation Desktop With 1 Monitor, Intel I7, Min. 16 Gb Ram, 8 Gb Graphic Cardincluding Minimum 20 Meter Hdmi / Dvi / Dp Cables 42 Workstation Desktop With 4 Monitor, Intel I7, Min. 16 Gb Ram, 8 Gb Graphic Cardincluding Minimum 20 Meter Hdmi / Dvi / Dp Cables ( 9 For Ssp Office, 3 For Ho ) 43 65 Smart Led Display / Tv, Full Hd With Wifi And Bluetooth For Ssp Office And Ho ) 44 40 Smart Led Display / Tv, Full Hd With Wifi And Bluetooth For Ssp Office And Ho ) 45 Uavs, Rotorcraft / Vtol Fixed-Wing Drones For Ariel Surveillance - Min. Take Off Altitude - 3000 Meters, Minimum 10 Km Of Flight Distance, Supporting Indian Navigation Satellite System - Gps + Galileo Having Omnidirectional Binocular Vision System, Supplemented With A 3D Infrared Sensor At The Bottom Of The Aircraft With Hasselblad Cameras Cmos, Minimum Effective Pixels: 20 Mp, Min. 256Gb Storage With Intelligent Flight Battery × 1, Remote Control × 1, Low-Noise Propellers ( Pair ) × 3, Portable Charger × 1 , Usb-C Cable × 1, Spare Rc Control Sticks ( Pair ) × 1Carrying Bag × 1And Required Software. 46 Pink Booth With Civil Work Including Following Components1 No. 2 Kva Invertor With Minimum 1 Hour Backup1 No. Ro Water Filter With Disposable Glasses1 Set Of Medical First Aid Kit 1 No. Discussion Table2 No. Discussion Chair2 No.S. Storage / Wardrobe1 No. Notice Board1 No. White Board1 No. Work Station With 1 Monitor2 Cctv Dome Cameras With Recording 2 Kva Ups With 30 Mins Backup10 Ltrs Room Cooler ( Water ) 2 No. Emergency Rechargable Light For The Booth With Charger1. No. Handheld Public Anouncement System1 No. Wifi Router1 Set Utensiles ( Plates, Glass, Cups, Etc ) Note:Clean Closed Space Will Be Provided By Greater Noida With Attached Washroom 47 Mobile Command And Control Vehicle. ( Mccv ) Including All The Below Components ( 2.01 To 2.27 ) - Please DonT Mention Separate Rates For Below Components 48 Mini Bus With Chassis: Wheel Base 3050 Mm ( Approx. ) From Reputed Oem Like Tata, Eicher, Ashok Leyland, Force Motors Etc. 49 Split Air Conditioner ( 1Ton ) 50 Interiors Design ( As Per The Requirement ) - For 1 Vehicle With External Branding 51 Seating Arrangement Tables And Chairs For Two Operator And Small Couch With Shock & Vibration Isolators For Stability And Safety 52 Console With Provision Formonitor / Display 53 Inter- Communication Service Console 54 19 Rack With Shock & Vibration Isolators For Electronic 55 Hydraulic Mast To Mount Ptz Camera And Light ( Min4 Mtrs Extended Height From Ground ) 56 Vehicle Mount Ip Outdoor 2 Mp Ptz Camera, Min 32X Optical 12 X Digital Zoom ( Ip 66 Housing, 24Vac / Poe+, 128 Gb Sd Card, Surge Protection Devices, All Type Of Cables Mounting Bracket With Bird Spikes And All Required Accessories ) With Keyboard And Joystick 57 Ip Fixed 4Mp Hd Bullet Camera With Ip 66 Rated Housing For Outdoor Use, 128 Gb Sd Card, Surge Protection Devices, Mounting Bracket, Bird Spikes, All Type Of Cables With All Required Accessories 58 Medium Storage ( Wooden Cupboard ) 59 Industrial Grade Pcwith 1 Monitor Support, Intel I7, Min. 16 Gb Ram, 8 Gb Graphic Cardincluding Minimum 3 Meter Hdmi / Dvi / Dp Cables And All Accessories. With Storage Of 4 Tb For Camear Recording. 60 32 ”Led Full Hd Tv With Fire Stick For Live Tv Footage 61 Modular True Online Ups With Adequate Capacity 3Kva With 30 Minutes Backup 30 Meter Raw Power Inlet Cable. 62 Min. 4.5 Or Above Kva Portable Inverter Generator Set, Fuel Type: Unleaded Petrol, Salient Design And Higher Efficiency. Monitor Equipped Engine Control Panel Display With Self-Start Feature. 63 Video Management Software With Licenses For Min. 3 Cameras 64 5G Based 4 Sim Aggregator Device With Sim With Recurring Charges To Be Provided By Gnida 65 Network Hardware Gige Switch 66 Led Flood Lights With 120-Degree Coverage ( Mast Mounted ) 67 Top Bar Light With Siren 68 Public Address System ( Pas ) With 2 Vehicle Mount Outdoor Speakers 69 Min. 5Kg Abc Powder Fire Extinguishers 70 Medical First-Aid Box 71 Mini Drinking Water Dispenser For 20 Litre Bottle 72 Integration, Testing, Installation, Commissioning & Training 73 Interoperable Communication System With Operator Display, Pedal Ptt, Speakers, Ptt Desk Mic & Record-Replay Features. 2 Base Station Radios And 2 Sim Cards For This Will Be Provded By Gnida 74 4G Aggregator / Bonding Receiver With Unlimited Bonding License 75 Hardware - Iccc Components 76 Workstation Desktop With 3 Monitor, Intel I7, Min. 16 Gb Ram, 8 Gb Graphic Cardincluding Minimum 3 Meter Hdmi / Dvi / Dp Cables And All Accessories 77 Workstation Desktop With 1 Monitor, Intel I7, Min. 16 Gb Ram, 8 Gb Graphic Cardincluding Minimum 3 Meter Hdmi / Dvi / Dp Cables 78 Laser Dlp Based Rear Projection Video Wall Dlp Cubes Of Minimum 70” Diagonal In A Configuration. Resolution Minimum55000 X 4200 Pixels ( Min. 230Mp ) With Controller, Software And All Accessories 79 Joystick To Control Ptz Cameras With All All Accessories 80 48 Port Gigabit Switch For Iccc 81 Minimum 2 Ton Air Conditioner For Iccc ( Approx 5000 Sq. Ft. Area ) 82 Iccc Interior, Furniture & Fixtures Including 1 Reception, 1 Visitor Room, 2 Meeting Rooms, 1Viewing Gallary Construction, Complete Civil, Interior Work And Furniture ( Tables, Chairs, Cubicle, Storage Racks, Separator Etc ) , Electrical Lightning And Fitting ( Approx. 3000 Sq. Ft Area ) Considering 30 Staff For Monitoring, 10 Person Meeting / War Rooms, 6 Person Visiting Room, 10 Person Viewing Gallary And Single Person Reception Area With All Other Utilities And Fixtures Like Signages ( Fire, Entry - Exit, Utilities Etc ) 83 Hardware - Data Center Components 84 48 Port Core Switch In High Availability ( Ha ) Mode 85 Internet Router In High Availability ( Ha ) Mode 86 48 Port Aggregation Switch In High Availability ( Ha ) Mode 87 Networking Racks ( 42U ) As Per Solution Requirement 88 Networking Racks ( 12U ) As Per Solution Requirement 89 Kvm Switch With Display / Managebale 24 Port Switch 90 Network And Cyber Security Audit ( Every Year ) For 5 Years 91 Servers Required For All The Applications And Softwares Including But Not Limited To Database, Video Management System, Video Analytics, Istms System ( Anpr, Rlvd, Svd, Traffic Video Analytics ) , Rlvd, Atcs, Istms, Speed Detection, E-Challan, Variable Message Signboard, Database Server, Ems Server, Web Server, Virtuakisation Server In Hamode To Make The System Complete. 92 48 Port Gigabit, Layer 3 Switch In Ha Mode 93 24 Port L2 Tor Switch In Ha Mode 94 48 Port L2 Tor Switch In Ha Mode 95 24 Port Gigabit, Layer 2 Switch 96 48 Port Gigabit, Layer 2 Switch 97 Antivirus, Syslog & Ems Server 98 San Raid 5 Forvirtualisation And Database 99 Nas Forvideo And Log Storage, Raid 5 Or Better For 90 Days Of Video And Alarm Data For 1300 Cameras At 25Fps, 1080P Resolution 100 Backup Appliance ( D2d ) Along With Backup Solution For 90 Days And Logged / Flagged Data For 180 Days For 1300 Cameras At 25Fps, 1080P Resolution 101 Precision Air Conditioning For Minimum 9 Racks In Data Centre 102 Misllaneous Components ( Common For Iccc And Data Center ) 103 2Mp Day And Night Dome Cameraswith 128 Gb Sd Card For Internal Surveillance In Iccc And Data Center 104 Network Video Recorder ( Nvr ) With Storage For 30 Days, Rack Mount With All Accessories For 10 Dome Cameras 105 Biometric ( Finger Print Based ) + Smart Card Based For Time And Attendance, Access Control System Minimum 200 Users For Iccc And Dc Area For All The Doors ( 50 No.S Smart Cards, Controller, Readers, Locks With Software And All Accessories ) 106 55 Smart Led Display / Tv, Full Hd With Wifi And Bluetooth For 2 War Room, Reception, Cafeteria, Vistor Gallary, 2 Meeting Rooms 107 Ip Based Unified Communication Solution With 20. No.S Of High-End Ip Phones ( Desktop Type ) For Iccc Helpdesk, Receptionist, Office Administrators, Operators And Other Staff. With Intuitive 4 Inch Or Bigger Color-Screen Lcd Notification Display, Modern Design, With Rich Functionalities, Integrated Poe, Complete With All Accessories 108 Pa System Dialling Console With Licenses With Integration For Iccc Area 109 Modular True Online Ups With Adequate Capacity 120Kva With 30 Minutes Backup ( 1+1 Redundancy ) For Iccc And Data Center Equipments. 110 Water Proofing And Water Leak Detection ( Wld ) System For Data Centre ( 400 Sq. Ft. ) , Ups Room ( 100 Sq. Ft. ) And Iccc ( 3000 Sq. Ft. ) 111 Rodent Prevention And Controlfor Iccc And Data Centre 112 Heavy Duty Color Laser Printer ( All In One Printer , Scanner, Copier ) Compatible With Wifi, Pc, Desktop And Mobile Devices With All Accessories 113 Software And Applications 114 Iccc Software 115 Itms Application Software 116 Video Management Software 117 Video Management Licenses With Failover 118 Facial Recognition Software With Base License And Channel License 119 Mobile App. ( Adroind And Ios Platform ) For Citizens And Staff In The Single App. 120 Va ( Video Analytics ) Licenses - Citizen Safety 121 Video Analytics Software- Citizen Safety Use Cases 122 Crowd Detection And Estimation 123 Person Collapse Detection 124 Object Abandoned Detection 125 Person Fighting Detection 126 Animal / Person Detection 127 Vandalism Detection 128 Loitering Detection 129 Fire Detection 130 Va ( Video Analytics ) Licenses - Traffic Management 131 Anpr Per Camera Licenses 132 Red Light Violation Software 133 Red Light Violation License 134 Echallan Software ( Integrated With Vahan Database Of Nic ) 135 Accident And Incident Reporting System ( Airs ) 136 Video Summarization Software For Video Synopsis 137 No Parking Violation Detection License 138 Triple Riding Violation Detection License 139 No Helmet Violation Detection License 140 No Seat Bealt Detection 141 Wrong Direction Driving Violation Detection License 142 Variable Message Signboard Software 143 Public Announcement System Software 144 Atcssoftware 145 Atcs Controller License 146 Vtds / Atcc Software Centralapplication ( As Per Boq ) 147 Integration With Rto Db And Other Interfaces 148 Other Software 149 Server Virtualization Software ( As Per Boq ) 150 Server Os ( As Per Boq ) 151 Anti-Virus Software ( As Per Boq ) 152 Db Software ( As Per Boq ) 153 Enterprise Management System ( Ems / Nms ) With Helpdesk, Sla, Asset, Report Management 154 Unified Platform For Database Integration With Constamized Business Intelligence ( Bi ) 155 Gis Map Base Software With Required Licenses For Geo Spatial Application 156 Manpower - Operations And Maintenance Phase ( 60 Months ) This Is Minimum Manpower, However Msi Shall Provide The Adequate Manpower For Project O&M Support 157 Project Directorno. Of Man Months And Availability At Site As Per Rfp Requirement And Project Completion Time Lines. 158 Project Managerno. Of Man Months And Availability At Site As Per Rfp Requirement And Project Completion Time Lines. 159 System And Nw Administrator For Data Centreno. Of Man Months And Availability At Site As Per Rfp Requirement And Project Completion Time Lines. 160 System And Nw Engineer For Field Infrano. Of Man Months And Availability At Site As Per Rfp Requirement And Project Completion Time Lines. 161 Technical Support Engineers For Field Infrano. Of Man Months And Availability At Site As Per Rfp Requirement And Project Completion Time Lines. 162 Field And Data Center Networking / Bandwidth 163 Dedicated Optical Fiber Networking Forall Field Devices At All Locations And Datacenter With Required Bandwidth ( Including Supply, Digging, Trenching, Laying And Maintenance For 5 Years ) As Per Above Mentioned Device Quantities In All Respects To Make The Solution Complete Including Pop Locations For Network Distributionnote: Closed Rooms For Pop Will Be Provided By Gnida However Interiors, And It Equipments Shall Be Provided By The Bidder With Required Hardware, Software, Other Passive Components, Power Backup And Hvac ) , Measurement Will Be Based On Digging Length

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Apr-2024 REVISED SCHEDULE Date 16-04-2024
2 16-Apr-2024 REVISED SCHEDULE 2 Date 30-04-2024

Key Value

Document Fees
INR 6770 /-
EMD
INR 23760000.0 /-
Tender Value
INR 227.59 Crore /-

Attachment

FileName File Description File Size
ed471e02-b16b-423b-a682-b7df92bb5b4e.html Tender Notice 0 KB
BOQ_1582216.xls Tender Document 0 KB
RFP_TRAFFIC.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail