Tender For Construction Of New 33/11 Kv Sub Station At Village Shyampur (Kontar) Under Bamori Dc Of Oandm Div Guna, Guna-Madhya Pradesh

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited-MPMKVVCL has published Tender For Construction Of New 33/11 Kv Sub Station At Village Shyampur (Kontar) Under Bamori Dc Of Oandm Div Guna. Submission Date for this Tender is 03-04-2024. Substation Tenders in Guna Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42824985
Corrigendum : Tender For Construction Of New 33/11 Kv Sub Station At Village Shyampur (Kontar) Under Bamori Dc Of Oandm Div Guna
Open Tender
Indian
Madhya Pradesh
Guna
03-04-2024

Tender Details

Construction Of New 33 / 11 Kv Sub Station At Village Shyampur ( Kontar ) Under Bamori Dc Of Oandm Div Guna

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Mar-2024 Date extend Date 03-04-2024

Key Value

Document Fees
INR 5900 /-
EMD
INR 161705.0 /-
Tender Value
INR 80.85 Lakhs /-

BOQ Items

Name of work :- Construction of New 33/11 KV Sub Station at Village Shyampur (Kontar) Under Bamori DC of O&M Div Guna. Estimate No. & Date :- 20-513-120665-23-00221 dt. 01.12.2023, STC W/o No.:- 366 dt. 08.12.2023, O&M W/o No.:- 5958 dt. 07.12.2023, Project No. :- 59476
Sl. No. Item Description
1Provision :- Schedule A :- 05 MVA PTR - 01 No. Schedule B:- 33 KV Line on PCC pole- 8.15 KM Schedule C:- 33 KV Road Crossing - 07 No. Schedule D:- 33 KV DP Structure - 09 No. Schedule E:- 33 KV TP Structure - 2 No. Schedule F:-11 KV line on PCC Pole - 5 KM Schedule G:- 11 KV DP Structure on PCC Pole - 06 No. Schedule H:- 11 KV Tapping DP on PCC Pole - 03 No. Schedule I:- 33 KV Tapping DP - 1 No.
2280 Kg.,9.1 Mtrs. long PCC pole
3Pole Erection of 280 Kg.,9.1 Mtrs. long PCC pole {(including Pit Digging - Base Padding of Pole by Stone Block/Pre Cost Block, Pole Erection, Back Filling/Boulder, Earthing Coil)}
4Back Clamp for 280 Kg PCC Pole of MS Flat 65x8mm.(Each weight 1.92 Kg)
5Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire
633 KV Pin Insulator Polymer Composite (10 KN)
7Erection charges for Fixing of 33 KV Pin Insulator Polymer Composite (10 KN)
8Stay set 20 mm. complete without Stay wire (Painted)
9Stay Set 20 MM. Complete Erection including Pit Digging, Binding of Stay wire at Eye bolt, Stay insulator and Anchor Rod & Tigting on pole)
10STAY GI WIRE 7/4.00 MM.(7/8 SWG)
11Clamp  65X8 MM of MS Flat for pcc Pole 280Kg. (Each weight 3.04 kg )
12Stay Insulators 90X65mm
13Back filling of poles with boulders.
14Stone Block/Pre cast block for base pedding(450X450X75MM)
15Concreting of structures & foundation (1:3:6)
16Erection Charges for Concreting of structures & foundation (1:3:6)
17Red oxide paint
18Erection Charges for Red oxide paint
19Aluminium paint
20Erection Charges for Aluminium paint
21Danger Boards Enamelled 33 KV
22Erection Charges for Fixing of Danger Boards Enamelled 33 KV
23M.S.Nuts with Bolts
2433 KV V cross-arms 75x75x6 mm angle
25Erection Charges for Fixing of 33 KV V cross-arms 75x75x6 mm angle
2633 KV Top Clamp
27Erection Charges for Fixing of 33 KV Top Clamp
28ACSR  Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.), (6/4.72 + 7/1.57 mm)
29Erection Charges for Stringing of (v) ACSR  Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.), (6/4.72 + 7/1.57 mm)
30Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG)
31Erection Charges for Fixing of Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG)
32WPB 160x160 MM, 30.44 KG/Mtr 13 Mtr. Long
33Pole Erection of WPB 160x160 MM, 30.44 KG/Mtr 13 Mtr. Long { (including Pit Digging - Base Padding of Pole by Stone Block/Pre Cost Block, Pole Erection, Back Filling/Boulder, Earthing Coil)}
34Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg)
35Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor
36Erection Charges for Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor
37Clamp  65X8 mm Flat of MS Flat for H-Beam (Each weight 3.2 kg)
38Aluminium Binding wire and tape
3933 KV Carpet guarding
40Erection Charges for Complete 33 KV Carpet guarding (GI Wire, I Bolts, Channel)
41I Bolts 20 MM
42G.I. Wires 5.00 MM (6 SWG)
43G.I. Wires 4.00 MM (8 SWG)
4433 KV (45KN) Composite Polymer Disc Insulators
45Erection Charge for Fixing of 33 KV (45KN) Composite Polymer Disc Insulators with Strain H/W
4633 KV Strain hardware (T&C type) fittings
47MS strain plate 65x8mm 250mm long
48D.C. Cross arms 5 ft centre to center (100x50x6 mm) Channel along with strain plates, Clamps
49Erection charges for fixing of D.C. Cross arms 5 ft centre to center (100x50x6 mm) Channel along with strain plates, Clamps
50Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 5 ft(1.5 mtr) centre DP
51Erection Charges for fixing of 5" centreHorizonatal and Cross Bracing withsupporting clamps on both the poles.)
52Crane Charges for Loading of 5 MVA PTR into Truck from Area Store Guna
53Crane Charges for Handling & Installation of Power Transformer with Fitting of All Radiator at S/s Plinth for site location upto 50 kms from crane availbality location {(33/11 KV Power transformer, OFTC Type , 5000 KVA (LOSS 5.5+33 KW) (Rep-BGP)}
54Fencing of S/s land with barbed wire
55Yard fencing with chain link mesh over brick wall
56MS main and  wicket gate on RCC column
57MS Sheet Shine Board, bay indication board & RYB phase indication board
58Ctrl room & Internal electrification work for Size 6.00 X 11.70 M for rural ar.
59Yard leveling with Moorum/Kopra.
60Laying of Metal in yard:100 mm thick metalling with 40 mm size B.T.
61Pro. avoid grass in sub-station yards detailed in (e-1) and (e-2) in Civil Stock
62Approach road with hume pipe culvert (WBM)
63App road(RCC 1:2:4)main gate to power xmer found size(20x3M)Black soil
64App road 60mm thick concr paver block M-30 grade along trench upto various equip
65Drilling of Bore Well, DIGGING 150 MM DIA TUBE WELL, CASING BEYOND 60 MTR.
661000L P/F Sintex OH tank & GI pipe fitting,water tap near X-mer neutral earthing
67Providing and fixing 5HP submersible pump
68P&F perfo cable tray 300 wide,2 thick fix  45x45x5 MS angle grouted CC 1:24
69ing brick massonery 0.6x0.6M inner,flag stone cover:18 no. earth pit
70Fire extinguisher cartridge CO2 10 kgs
71Cost of retaining wall 1.5 M high as per site requirement
7233 KV VCB, Outdoor Porcelain clad  type with complete structure and accessories excluding CT & pannel
73Handling & Installation of 33 KV VCB, Outdoor Porcelain clad  type with complete structure and accessories excluding CT & pannel
7433 KV CTs.Outdoor Oil immersed type 200-100/5 Amps
75Handling & Installation of 33 KV CTs.Outdoor Oil immersed type 200-100/5 Amps
7633 KV control & relay panel with  static relay for Transformer protection
77Handling & Installation of 33 KV control & relay panel with  static relay for Transformer protection
7833 KV control & relay panel with numerical static relay for Feeder protection
79Handling & Installation of 33 KV control & relay panel with numerical static relay for Feeder protection
8011 KV VCB, Outdoor Porcelain clad  type with complete structure and accessories excluding CT & pannel
81Handling & Installation of 11 KV VCB, Outdoor Porcelain clad  type with complete structure and accessories excluding CT & pannel
8211 KV.C.Ts.(Outdoor dry type)  300-150/5-5 Amps
83Handling & Installation of 11 KV.C.Ts.(Outdoor dry type)  300-150/5-5 Amps
8411 KV control & relay panel with  static relay for Transformer protection
85Handling & Installation of 11 KV control & relay panel with  static relay for Transformer protection
8611 KV control & relay panel with  numerical static relay for double feeder protection
87Handling & Installation of 11 KV control & relay panel with  numerical static relay for double feeder protection
88Marshelling box with 10 no. connectors
89Erection Charges for Marshelling box with 10 no. connectors
909 KV Gapless type  Metal oxide (10 KA)  Polymer for 33/11 kv S/s type
91Erection Charges for fixing of 9 KV Gapless type  Metal oxide (10 KA)  Polymer for 33/11 kv S/s type
9233 KV Single Phase PTs.
93Handling & Installation of 33 KV Single Phase PTs.
94SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB
95Direct Curent Distribution Board (DCDB) 24 Volts Indoor floor/ wall
96Erection Charges for Direct Curent Distribution Board (DCDB) 24 Volts Indoor floor/ wall
97ACDB  415 V, along with  three phase-neutral voltmeter,  three phase ammeter
98Erection Charges for ACDB  415 V, along with  three phase-neutral voltmeter,  three phase ammeter
99T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG
100Erection Charges for T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG
101Bi Metallic Clamp for Power Transformer of Brass Flat 50x50x10MM
102Erection Charges for Bi Metallic Clamp for Power Transformer of Brass Flat 50x50x10MM
103H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-9 mtr. Long= 333.9 kg
104Pole Erection of H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-9 mtr. Long= 333.9 kg {(including Pit Digging - Base Padding of Pole by Stone Block/Pre Cost Block, Pole Erection, Back Filling/Boulder, Earthing Coil)}
105Stringing of Each 33 KV  Bus- upper and lower including  drop jumpering, jointing with clamps, incoming DP/ ME  to BUS
106Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer
107Stringing of All 33 KV & 11 KV Jumpers - from 33 KV gartry  through 33 KV VCB to PTR to 11 KV gantry through 11KV VCB
10833 KV composite polymer Strain set with hard ware suitable for Panther Conductor
109H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-11 mtr. Long = 408.1 kg
110H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-11 mtr. Long = 408.1 kg Pole erection-[Including Pit Digging- Base padding of pole by Stone Block/Pre cost Block, pole erection, back filling/boulder, earthing coil]
11111 KV Pin Insulator Polymer Composit (5 KN)
112Erection Charges for fixing of 11 KV Pin Insulator Polymer Composit (5 KN)
113Stay set complete without Stay wire 16 mm. (Painted)
114Stay set complete without Stay wire 16 mm. (Painted) (Stay set 16 mm. Complete erection including Pit digging, binding of stay wire at eye bolt , stay insulator and anchor rod & tigtning on pole)
115STAY WIRE 7/3.15 MM.(7/10 SWG)
116Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay
117Labour Charges for Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay
118BIS certified Energy Efficiency Level-III (Old)/Level-II (New) Convential 11/0.433KV, 100 KVA Distribution Transformer
119Handling & Installation ofBIS certified Energy Efficiency Level-III (Old)/Level-II (New) Convential 11/0.433KV, 100 KVA Distribution Transformer (Distribution Transformer (DTR) on DP, tightening with turn buckles on both sides, poles clamping and boting of base jumpering on HT side (Including hydra charges in urban area and chain pully charges in rural area)
120Clamp A type 65x8mm of MS Flat for R.S. Joist(175x85mm)
12111 KV(45KN) Composite Polymer Disc Insulators
122Erection Charges for fixing of 11 KV(45KN) Composite Polymer Disc Insulators with Strain H/W
12311 KV Strain hardware (T&C type) fittings
12411 KV D.O. Fuse Unit Polymer type (Erection Charges for 11 KV D.O. fuse & Lightening Arrestor mounting channel (75X 40 X 6 mm.) )
125Handling & Installation of 11 KV D.O. Fuse Unit Polymer type (Erection Charges for 11 KV D.O. fuse & Lightening Arrestor, mounting channel (75X 40 X 6 mm.) )
126Transformer clamping set 50X50 X6 mm Angle 460mm long
127Complete jumpering of DTR
128Danger Boards Enamelled 11 KV
129Erection Charge for fixing of Danger Boards Enamelled 11 KV
130L.T. Distribution box with Isolator on Incoming with HRC fuse for 100 KVA DTR
131Handling & Installation of L.T. Distribution box with Isolator on Incoming with HRC fuse for 100 KVA DTR (300 Amp. Isolator & 6 no. J type Al Hook) (Dist. Box on DP, complete wiring, connecting LT cable on bushing and LT feeders (2 Nos.))
132Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth
133Labour Charges for Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth
134Erection of Plinth per VCB- 33KV or 11KV [Pit digging-size(3x2x0.6) = 3.6 cu. Mtr,Base filling byKopra -1.92 cmt., concreting, curing and back filling of pits ]
135PTR Fndn.Cncrt.:1:1.5:3 Rio 5.634,1:5:8 Rio 7.545 cmt&M.S.Flat/rod 324.87 kg
136Erection Charges for PTR Fndn.Cncrt.:1:1.5:3 Rio 5.634,1:5:8 Rio 7.545 cmt&M.S.Flat/rod 324.87 kg
137Furniture for control room  Table 600mmx 900mm- 1no., Chair- 3no.,
138Indoor heat shrinkable cable  end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 120 sq mm
139Erection Charges for Indoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 120 sq mm (Cable end terminal/Straight through Jointing including Kerosine/Gas, Tools and other Materials required for jointing by Epoxy Compound Kit for 11 KV with testing and Lead Marking) (with lugs)
140G.I. STRIP 25X3 MM1
141G.I. STRIP 25X3 MM1 (G.I. Strip 25x3 mm. for laying complete earthing including welding and back filling)
142Earthing Rod 3 mtrs.(Gelvanised) 25 mm Rod
143Erection Charges for Earthing rod 3 mtrs.(Gelvanised) 25 mm errection with pit digging & back filling) [Earthing rod 3 mtrs.(Gelvanised) 25 mm rod (single spike/earth rod 10 pits distributed for mesh formationavoiding PTR movement area)]
144GI Pipe 150 mm B Grade
145Erection Charges for GI Pipe 150 mm B Grade (Erection charges forbore through T/w drilling machine suitable for G.I. Pipe150 mm ) [GI pipe 150 mm., B class with the length of average depth 30 mtr. X 8( 2 for PTR neutral, 4 for mesh, 2 for LA)+10*1(10 Mtsr for Control room ) no. ]
146Galvanized Iron (GI) Flat 50X6 MM
147Galvanized Iron (GI) Flat 50X6 MM (G.I.Flat 50x6 mm. digging of 0.5 m deep trench for laying earthing including welding and back filling) [Galvanised mild steel flat (50x6 mm.) For mesh as per details (i) Along PTR 35mx2no.=70 M. across (ii)PTR Alingment 15 m x 7 no.+ 20 x 3 (165 m), (iii) Connections of mesh to 1 earth spike / pipe 0 .5mx 10no. 5m (iv) Connections of mesh to 4pipes earth 8mx 2no. 16 m (v)Connections for 11& 33 kvVCB5mx14 no. 70 m (vi) Connections for 11& 33 kv ct8mx14 no. 112 m (vii)Connections for 11& 33 kv ME20mx 5no. 100 m (viii) Connections for 11& 33 kv LA 30mx 7 no. 210 m (ix) Double connections for PTR neutral and body earth38mx 1 no. 38 m (x)Connections for AB, Isolater handel, 4mx11no. 44m]
148G.I.Pipe 40 mm Dia C grade type
149G.I.Pipe 40 mm Dia C grade type (G.I. Pipe 40 mm dia errection with pit digging & back filling) [GI pipe 40 mm.,( 3 mtr.Each pipe) (total no. of pits 3 & set of 4 no. Pipe in 2 pits (2x1.5x3m=9 cubic mtr) for neutral and LA]
150Bentonite compound powder
151Galvanized nut & bolt with washer
1523 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT  trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering)
1533 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT  trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering) (Erection rate of installationof HTmeter(11 KV / 33 KV both) excluding ME with modem complete ,meter box with TTB, cabling & wiring )
154ACSR  Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.)
155AAAC  Rabbit conductor  0.05 sq. inch. (55 sq.mm. Al.Eq.)
156Stringing of AAAC  Rabbit conductor  0.05 sq. inch. (55 sq.mm. Al.Eq.)
15711 KV Under-Ground XLPE armoured Cable 3X150  Sq.mm.
158Stringing of 11 KV Under-Ground XLPE armoured Cable 3X150  Sq.mm.
159XLPE Cable 1 core unarmoured 150 sqmm Aluminium conductor 1100 Volts
160Stringing of XLPE Cable 1 core unarmoured 150 sqmm Aluminium conductor 1100 Volts
161XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts
162Stringing of XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts
163PVC insulated 4 core unarmoured 16 sqmm Aluminium conductor 1100 Volts
164Stringing of PVC insulated 4 core unarmoured 16 sqmm Aluminium conductor 1100 Volts
165PVC insulated 2 core  armoured 2.5 sqmm Aluminium conductor 1100 Volts
166Stringing of PVC insulated 2 core  armoured 2.5 sqmm Aluminium conductor 1100 Volts
167Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured)
168Stringing of Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured)
169Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured)
170Stringing of Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured)
171Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured)
172Stringing of Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured)
173Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured)
174Stringing of Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured)
175R  S joist 175x85mm 19.6kg/mtr 9 mtr long = 182.28 Kg
176R  S joist 175x85mm 19.6kg/mtr 9 mtr long = 182.28 Kg Pole Erection {(including Pit Digging - Base Padding of Pole by Stone Block/Pre Cost Block, Pole Erection, Back Filling/Boulder, Earthing Coil)}
177D.O.Mounting Channel  75x40x6mm
178D.C. Channel 100x50x6mm 4.8 mtrs center to center
179Erection Charges for D.C. Channel 100x50x6mm 4.8 mtrs center to center along with strain plates, clamps
180Transformer mounting  Channel (100X50x6 mm.)
181Erection Charges for Transformer mounting  Channel (100X50x6 mm.)
182D.C. Cross-arms 8 ft centre to center (100x50x6mm)  Channel
183Erection Charges for D.C. Cross-arms 8 ft centre to center (100x50x6mm)  Channel along with strain plates, clamps
184Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 8 ft (2.4 mtr ) centre DP
185Erection for 8" Centre Horizonatal and Cross Bracing withsupporting clamps on both the poles.
18633 KV Top clamps 75x75x6 mm Angle (S/s)
187Erection Charges for 33 KV Top clamps 75x75x6 mm Angle (S/s)
18811 KV Top clamp 65X65X6 mm. angle type (S/s)
189Erection Charges for 11 KV Top clamp 65X65X6 mm. angle type (S/s)
190LED Lamp with 90 Watt (Complete)
191Labour Charges for LED Lamp with 90 Watt (Complete)
19230 V -10Amp Battery Charger Rectifier type
193Handling & Installation of 30 V -10Amp Battery Charger Rectifier type
19430 V 200 Amp Hour Battery Set in Transparent SAN Container
195Handling and Installation for 30 V 200 Amp Hour Battery Set in Transparent SAN Container
19633 KV Polymer Lightening arrestor Gapless type
197Erection Charges for 33 KV Polymer Lightening arrestor Gapless type
19811 KV Composite Polymer AB Switch Horizontal Movement type
199Erection Charges for 11 KV Composite Polymer AB Switch Horizontal Movement type
20033 KV Composit Polymer AB Switch
201Erection Charges for 33 KV Composit Polymer AB Switch
20211 KV PT Single Phase
203Handling & Installation of 11 KV PT Single Phase
20433 KV CT Outdoor Oil immersed type 300-150/5-5 Amps
205Handling & Installation of 33 KV CT Outdoor Oil immersed type 300-150/5-5 Amps
206Iron Steel Scrap
207140 Kg.,8.0 Mtrs. long PCC pole
208140 Kg.,8.0 Mtrs. long PCC Pole Erection - (including Pit Digging - Base Padding of Pole by Stone Block/Pre Cost Block, Pole Erection, Back Filling/Boulder, Earthing Coil)}
209Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm
210Clamp for 140 Kg PCC Pole MS Flat 50x6 mm
211G.I. WIRES  4.0 MM. (8 SWG)
212Labour Charges for G.I. WIRES  4.0 MM. (8 SWG)
213Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay
214Labour Charges for Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay
21511 KV V cross arm 65X65X6 mm. angle type
216Erection Charges for Fixing of 11 KV V cross arm 65X65X6 mm. angle type
21711 KV Top Clamp
218Erection charges for fixing of 11 KV Top Clamp
219AAAC  Raccoon conductor  0.075 sq. inch (80 sq.mm. Al.Eq.)
220Stringing of AAAC  Raccoon conductor  0.075 sq. inch (80 sq.mm. Al.Eq.)
221Earthing for PCC Pole  4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole
222GST @ 18%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail