Public Health And Engineering Department has published Tender For Work Of Narmada Based Water Supply Project For 451 Villages Of Sindhari-Dhorimanna And Barmer Blocks District Barmer (Package Cp-02, Hr-1, Hr-2 Under Jica Funded Rajasthan Rural Water Supply & Fluorosis Mitigation Project Phase Ii On Spr Basis . Submission Date for this Tender is 22-05-2024. Water Supply Project Tenders in barmer Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Apr-2024 | Addendum 1 | Technical Bid | 06-05-2024 |
2 | 29-Apr-2024 | date extension | Date | 22-05-2024 |
FileName | File Description | File Size |
bc3b6904-e354-4cd4-97c8-a860957d724a.html | Tender Notice | 0 KB |
BOQ_691172.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
VOLUME-I.pdf | Tender Document | 0 KB |
VOLUME-II.pdf | Tender Document | 0 KB |
VOLUME-III.pdf | Tender Document | 0 KB |
VOLUME-IV.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | BILL 1 - WATER TREATMENT PLANT |
2 | Survey, Design, Construction, Testing and Commissioning of Rapid Gravity Water Treatment Plant (Output Capacity 10 MLD) including all relevant Civil, Electrical, Mechanical, Instrumentation, Automisation, SCADA Worksalong with Ancillary Civil Works as per specifications and Employer"s requirement complete in all respect. at DHEEMRI HW. (Instrumentation, Automisation and SCADA works shall be paid as per Section for Instrumentation, Outdoor Switchyard as per Section for Electrical) |
3 | Inlet and Distribution System: Inlet chamber, Measuring channel, Flash Mixers, Main/ By Pass Channel to Filter Beds, Walkways, Stairs, Railings etc. |
4 | Equipments |
5 | Civil works |
6 | Clariflocculators: Pipes between Flash Mixers and Clariflocculators, Clariflocculators, Walkways, Stairs, Railings, Clarified Water Channel to the Filter Inlet Channel and Sludge Pipe to Sludge Buffer Tanks etc. |
7 | Equipments |
8 | Civil works |
9 | Filters and Filter House: Filters,Distribution/ Back Wash Channel, Pipe Gallery with Clear Water Channel and Sump, Control Gallery, observation Platforms, Walkways, Stairs, Railings, Back Wash Water Tank, Clear Water Measuring Channel, etc. |
10 | Equipments |
11 | Civil works |
12 | Administrative and Control Building: Administrative Control Building, Backwash Pumps, Air Blowers, Laboratory Equipment, Water Cooler, Furniture etc. as per Scope of Work and Specifications |
13 | Equipments |
14 | Civil works |
15 | Chemical House: Chemical House, Alum/PAC and Lime Dosing Equipment, Piping to the Injection Point and Injection Devices |
16 | Equipments |
17 | Civil works |
18 | Chlorine Building, Chlorination and Chlorine Storage: Chlorine Storage Area, Chlorine Building, Chlorine Toners, Chlorination Equipments, Chlorination Chamber, Injection Devices etc |
19 | Equipments |
20 | Civil works |
21 | Backwash Water and Sludge Recycling and Disposal: Construction of Wwater Recirculation System including associated work of Inlet/Outlet, Recycling of Backwash Water and Sludge Handling and Disposal System, Pumps and Piping etc. |
22 | Equipments |
23 | Civil works |
24 | BILL-2 - PIPELINE WORKS |
25 | Earth work in Excavation in all kind of Strata, Sand/Soil Bedding wherever required, disposal of surplus excavated Earth for the Trench, Road Cuttings (other than National/State/Mega Highway/GREF Road), River / Drain and Canal/Gas/Petroleum Pipelines Crossing (other than pushin), Construction of Pedestals, Anchor/Thrust/Fixidity Blocks, Cross walls, Protective Aprons, Encasing, other Civil Worksetcas per specifications and Employer requirement for following diameter Pipe Line:- |
26 | 75mm |
27 | 90mm |
28 | 100 mm |
29 | 110mm |
30 | 125mm |
31 | 140mm |
32 | 160mm |
33 | 150 mm |
34 | 180mm |
35 | 200 mm |
36 | 225mm |
37 | 250 mm |
38 | 300 mm |
39 | 350 mm |
40 | 450 mm |
41 | 500 mm |
42 | Survey, Design, Supply, Laying, Jointing, Testing and Commissioning of ISI markedS/SDI (Ductile Iron) K7 Class Pipeas per IS:8329-2000 (Amended up to date) for Raw / Clear Water Transmission, ESR/ GSR Rising Main, Cluster/Village Distributionincluding Flanged Pipes wherever required, Socket/Flanged Specials and Isolations and Interconnection works with existing system where dovetailing is required . This work also includes the required Laying above the Ground Level, Crossing requiredfor Drain, Canal, River and Road crossingswith Reinstatement Works,following diameters of Pipe Linesas per Employer requirement and Specification.(Payment for Casing Pipe to CrossNational/State/Mega Highway/GREF Road shall be made as per seperate item. However, MS / DIDF / Fitting for other to this shall be paidin this section ). |
43 | 100 mm |
44 | 150 mm |
45 | 200 mm |
46 | 250 mm |
47 | 300 mm |
48 | 350 mm |
49 | 450 mm |
50 | 500 mm |
51 | Survey, Design, Supply, Laying, Jointing, Testing and Commissioning of ISI markedS/SDI (Ductile Iron) K9 Class Pipeas per IS:8329-2000 (Amended up to date) for Raw / Clear Water Transmission, ESR/ GSR Rising Main, Cluster/Village Distributionincluding Flanged Pipes wherever required, Socket/Flanged Specials and Isolations and Interconnection works with existing system where dovetailing is required . This work also includes the required Laying above the Ground Level, Crossing requiredfor Drain, Canal, River and Road crossingswith Reinstatement Works,following diameters of Pipe Linesas per Employer requirement and Specification.(Payment for Casing Pipe to CrossNational/State/Mega Highway/GREF Road shall be made as per seperate item. However, MS / DIDF / Fitting for other to this shall be paidin this section ). |
52 | 100 mm |
53 | 150 mm |
54 | 200 mm |
55 | 250 mm |
56 | 350 mm |
57 | Survey, Design, Supply, Laying, Aligning, Fixing in position, Jointing, Testing, Commissioningof ISI marked HDPE Pipes of Class PE 80, PN-6 suitable for Potable Water as per IS 4984:1995 (Amended upto date) withSpecials and necessary Jointing Material like Mechanical Connectors i.e. Thread / Insert Joint / Quick Release Coupler Joint /Compression Fitting Joint or Flanged Joint and Special Jointing Pipe by Butt Fusion / Electro Fusion Welding method,Flanged Joints shall be used for Jointing HDPE Pipes to Valves and Non-HDPE Pipes. This work also includes the Drain/ Canal/ River/ Road Crossingswith Reinstatement works forfollowing outer diameters of Pipe Lines as per Employer"s Requirement and Specification :(Payment for Casing Pipeto CrossNational/State/Mega Highway/GREF Roadshall be made as per seperate item. However MS / DIDF / Fitting for other to this shall be measured in this section ).- |
58 | 75mm |
59 | 90mm |
60 | 110mm |
61 | 125mm |
62 | 140mm |
63 | 160mm |
64 | 180mm |
65 | 200mm |
66 | 225mm |
67 | Supply, Installation, Testing and Commissioning of following diameter PN 1.0 Rating Tamper ProofCI Single Air valveincluding construction of RCC Air Valve Shaft (height 3.0m above ground level) complete work on DI/HDPE Pipe Lines as per Employer"s Requirement and Specification - |
68 | 25 mm |
69 | 40mm |
70 | 50mm |
71 | Supply, installation, Testing and Commissioning of following diameter PN 1.6 Rating DI Kinetic type temper proof Double orifice Air Valve with Isolation Valves including construction of RCC Air Valve Shaft(height 3.0m above ground level) complete work on DI/HDPE Pipe Lines as per Employer"s Requirement and Specification - |
72 | 40mm |
73 | 50mm |
74 | 80mm |
75 | 100mm |
76 | Supply, Installation, Testing and Commissioning of following diameter PN 1.0 Rating CI Scour Valveswith Dismantling Joints, Fittings and Specials, complete work at all required locations per Employer"s Requirement and Specification:- |
77 | 80mm |
78 | 100mm |
79 | Supply, Installation, Testing and Commissioning of following diameter PN 1.6 Rating CI Scour Valveswith Dismantling Joints, Fittings and Specials,complete work at all required locations as per Employer"s Requirement and Specification:- |
80 | 80mm |
81 | 100mm |
82 | Supply, Installation, Testing and Commissioning offollowing diameter suitable RatingDI Soft Seated Sluice Valves for Off takes/Junctions, Sectionalising, outside of pump house and at upstream of FCV to Pipe Line, Either sides of NH/SH/Mega Highway/GREF Roads Crossing (if required) including in-village pipelines as per Employer"s Requirement and Specification:- |
83 | PN 1.0 |
84 | 80mm |
85 | 100mm |
86 | 125mm |
87 | 150mm |
88 | 200mm |
89 | 250mm |
90 | 300mm |
91 | 350mm |
92 | 450mm |
93 | 500mm |
94 | PN 1.6 |
95 | 100mm |
96 | 150mm |
97 | 200mm |
98 | 250mm |
99 | 300mm |
100 | Supply, Installation, Testing and Commissioning of following diameter suitable RatingDI Soft Seated Butterfly Valves for Sectionalising to Pipe Line as per Employer"s Requirement and Specification:- |
101 | PN 1.0 |
102 | 350mm |
103 | 450mm |
104 | 500mm |
105 | PN 1.6 |
106 | 350mm |
107 | Supply, Installation, Testing and Commissioning of following diameter suitable RatingDismantling Joints as per Employer"s Requirement and Specification:- |
108 | 80mm |
109 | 100mm |
110 | 125mm |
111 | 150mm |
112 | 200mm |
113 | 250mm |
114 | 300mm |
115 | 350mm |
116 | 450mm |
117 | 500mm |
118 | Supply, Installation, Testing and Commissioning offollowing diameter suitable RatingPlungar Type Flow and Pressure Control Valves along as per Employer"s Requirement and Specification:- |
119 | 80mm |
120 | 100mm |
121 | 125mm |
122 | 150mm |
123 | 200mm |
124 | 250mm |
125 | Carrying out Surge Analysis, Construction, Supply, Installation, Testing and Commissioning of suitable Surge Controlled Devices as approved with all Piping, Valves, Accessories forthe Transmission and Rising/ Pumping Mains complete as per Employer"s Requirement and Specifications :- |
126 | Transmission Main |
127 | Raw Water Transmission Main from HEADWORKS GANDHAV TO DHEEMRI |
128 | HEADWORKS-DHEEMRI to Peeprali, Loharwa |
129 | TPS-LOHARWAS to Dhorimanna, Misari ki Beri |
130 | TPS-DHORIMANA to KANHIYA NAGAR |
131 | TPS-SOBHALA JETMAL to Meethiya Tala |
132 | TPS-Dheemri to Berigaon |
133 | TPS-GUDAMALNI to KHADALI, MANGLE KI BERI,AADEL |
134 | TPS-AADELto NIMBAL KOT,KOSLU |
135 | ESR Rising Main |
136 | CPS-BERI GAON |
137 | H.W DHEEMRI |
138 | IPS-GUDAMALANI |
139 | CPS-KHADALI CPS |
140 | IPS-ADEL |
141 | CPS-NEEMBAL KOT |
142 | IPS-KOSHLOU |
143 | CPS-KADNARI |
144 | IPS-BHEDANA |
145 | CPS-RATANPURA |
146 | CPS NOKHRA |
147 | CPS-MANGLE KI BERI |
148 | CPS PIPRALI |
149 | IPS-DHORIMANNA |
150 | CPS-KANAHAIYA NAGAR |
151 | IPS-LOHARWA |
152 | CPS-MISARI KI BERI |
153 | IPS-SOBHALA JETMAL |
154 | CPS-MEETHIYA TALA |
155 | Survey, Design, Supply, Lying and Pushing of MS Casing Pipe of specified thickness approved by concerned Department Authority by Trenchless Method adopting any suitable Technology Below Ground at required depth under Running Traffic Condition as per NH/SH/GREF/MEGA Highway Standard, including Excavation of Driven Pits and Exit Pit with proper Protection, Construction of Temporary Works etc. as per approved by concernAuthority Specificationas per Employer"s Requirement Specification for following CarrierPipe diameter (Carrier Pipe shall be measured in Pipe Line Lengthas above, Sluice Valve at U/S and D/S if required shall be paid as per seperate item) |
156 | 200mm ID 8mm thick |
157 | 300mm ID 8mm thick |
158 | 400mm ID 8mm thick |
159 | 500mm ID 10mm thick |
160 | 700mm ID 10mm thick |
161 | Survey, Design, Construction of RCC valve chambers for Sectionalizing valves,offftake/junction valves, flow meters(FM+DJ) and (FM+DJ+SV), complete work at all required locations. This also includes excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials for following pipe sizes as per employer"s requirement and Specification :- |
162 | up to 125 mm (Minimum size 1.13mx0.85m) |
163 | above 125 mm & up to 200mm (Minimum size 1.17mx0.95m) |
164 | above 200 to 300mm (Minimum size 1.26mx1.185m) |
165 | 350 to 450mm (Minimum size 1.39mx1.43m) |
166 | 500 to 700mm (Minimum size 1.61mx1.75m) |
167 | Survey, Design, Construction of RCC chambers for Scourvalves, supports, complete work at all required locations. This also includes end excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials for the following Valve sizes as per employer"s requirement and Specification :- |
168 | 80/100 mm dia (Minimum size 1.13mx0.85m) |
169 | Survey, Design, Construction of RCC chambers for SV+DJ+FCV+FM+DJ, within campus, supports, complete work at all required locations. This also includes end excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials the following Valve sizes as per employer"s requirement and Specification :- |
170 | up to 250mm (Minimum size 3.0mx1.5m) |
171 | BILL-3 - RESERVOIR WORKS |
172 | Survey, Design, Construction, Testing, Commissioningof circular RCC Clear Water reservoirs including CI/DI puddle collars for inlet, one/two outlets, overflow and washout. It also includes overflow pipe up to the chamber, washout pipe with sluice valves (both of these piping upto the chamber where these will join storm water drain pipe), construction of chamber to join overflow+washout with storm water drain pipe complete in all respect at following locations:- |
173 | AT BERI GAON (500KL) |
174 | AT KHADALI (400KL) |
175 | AT NEEMBLI KOT (500KL) |
176 | AT MANGLE KI BERI (500KL) |
177 | AT NOKHRA (400KL) |
178 | AT RATANPURA (600KL) |
179 | AT Dhorimana (500KL) |
180 | AT Meethiya Tala (700KL) |
181 | AT Shobhala Jetmal (700KL) |
182 | AT Misari Ki Beri (300KL) |
183 | AT Kanhaiya Nagar (400KL) |
184 | AT Loharwa (1500KL) |
185 | AT Dheemari HW (1600KL) |
186 | AT Peeprali HW (200KL) |
187 | Survey, design, Construction, Testing, Commissioningof RCC Elevated Service reservoirs at different locations and as per the stated effective capacity includingCI/DI puddle collars for inlet, outlet, overflow and washout. It inludes providing and fixing D/F DI vertical pipes for inlet, outlet, overflow and washout along with ductfoot bends, Valves along with Dismantling Joints on inlet, outlet and washout pipes; making by pass arrangements along with Sluice Valve with Dismantling joints for by passing the ESR for supplying water directly from inlet, making connection of overlow pipe with washout on the downstream of its" Sluice Valve approximately at 6m away from ESR, providing and laying NP pipe from the junction of overflow with washout with minimum 20m length. Making Header on the outlet pipe (on the downstream of by pass arrangements) to faciliate joining more than one cluster distribution pipeline emanating from the ESR, Plinth Protection, Levelling and Plantation in campus, Chambers, Lightneing arrestor Complete in all respect with Design and Construction of RCC FramedService Room ( Min size 2.4m x 2.4m ) in the ESR campusas per employers requirementsand specifications : (Rates are invited for SBC 7 MT/Sqm, 18m staging, Earthquake zone III/IVas per IS 1893; However payment shall be made as per Conditions of Contract Agreement.) For staging above 18 meters,2% per meter increase over quoted rates shall be payable. Staging above 22m will not be allowed. |
188 | 100 KL |
189 | 150 KL |
190 | 200 KL |
191 | 250 KL |
192 | 300 KL |
193 | 350 KL |
194 | 400 KL |
195 | Demolition and disposal of abundant ESR at Beri Gaon as per General and Particular Specification and Employer"s requirement. |
196 | BILL-4PUMPING STATION WORKS |
197 | Civil WORKS |
198 | Survey,Design and Construction of RCC framed type structure Pump House with transition zone (with provision of trash rack from existing outlet Chamber , Sump for raw water pump house to accommodate VT pumps, providingassociated Electrical and plumbing works for water supply and sanitation, Civil work required for installation of gantry for Semi EOT crane, Pipes and specials, collectionsystem for rain water frompump house roofto thesumpcomplete in all respect as per employer"s requirement and Specifications at following location:- |
199 | GANDHAV |
200 | Survey, Investigations, Design andModification, Construction in existing intake structure to accommodate VT pumps, associated Electrical and MS section work complete in all respect as perEmployer requirement andSpecifications at following location:- |
201 | Dheemri (RWR to WTP) |
202 | Survey,Design and Construction of RCC framed structure pump house buildingto accommodate C/ F pump sets, Maintenance bay, Control Roomwith associate Electrical / Plumbing work. Thisshall include Civil works required for erection of Semi EOT crane,installation of pumps and panels, cable trenches, drainage, access platforms, ladders, thrust/anchor blocks, pipe supports,etc. within and outside the pump house as per employer"s requirement and Specificationat following locations:- |
203 | DHEEMRI |
204 | MANGLE KI BERI |
205 | BERI GAON |
206 | RATANPURA |
207 | KADANARI |
208 | KOSHALU |
209 | KHADALI |
210 | NOKHRA |
211 | NIMBAL KOT |
212 | LOHARWA |
213 | PIPRALI |
214 | SHOBHALA JETMAL |
215 | MISARI KI BERI |
216 | DHORIMANNA |
217 | MEETHIYA TALA |
218 | KANHAIYA NAGAR |
219 | Supply of office furniture as per Employer requirement and Specification as per Specifications at GANDHAV RWPH, Gudamalani, DHEEMRI TPS-cum-CPS, MANGLE KI BERI CPS,BERI GAON CPS, RATANPURA CPS,KADANARI CPS,KOSHALU CPS, KHADALI CPS, NOKHRA CPS,NIMBAL KOT CPS,T LOHARWA IPS-cum-CPS, PIPRALI CPS, SHOBHALA JETMAL IPS-cum-CPS,MISARI KI BERI CPS, DHORIMANNA IPS-cum-CPS,MEETHIYA TALA CPS, KANHAIYA NAGAR CPS |
220 | MECHNICAL WORKS AND PUMPING MACHINARY:- Design, Providing , Installation, Testing, Commissioningfor following as per Employer requirement and Specification:- |
221 | MS pipe work for suction piping, from puddle Collar in CWR and common cum individual suction header and all miscellaneous bore in pump house wall at following location :- |
222 | AT MANGLE KI BERI CPS |
223 | AT BERI GAON CPS |
224 | AT RATANPURA CPS |
225 | AT KADANARI CPS |
226 | AT KOSHALU CPS |
227 | AT KHADALI CPS |
228 | AT NOKHRA CPS |
229 | AT NIMBAL KOT CPS |
230 | AT GUDHAMALANI CPS |
231 | AT ADEL CPS |
232 | AT BHEDANA CPS |
233 | AT PIPRALI CPS |
234 | AT MISARI KI BERI CPS |
235 | AT MEETHIYA TALA CPS |
236 | AT KANHAIYA NAGAR CPS |
237 | AT DHEEMRI CPS |
238 | AT LOHARWA CPS |
239 | AT SHOBHALA JETMAL CPS |
240 | AT DHORIMANNA CPS |
241 | MS pipe work for suction piping, from puddle collar in CWR and common suction header and individual suction header and all miscellaneous bore in pump house wall at following locations :- |
242 | AT DHEEMRI TPS |
243 | AT LOHARWA TPS |
244 | AT SHOBHALA JETMAL TPS |
245 | AT DHORIMANNA TPS |
246 | MS pipe work for reducer, enlarger, inividual delivery piping of each pump and common delivery header up to Valve/flow meter and related works including bore in walls at following locations as -:- |
247 | AT GANDHAV RWPH |
248 | AtDheemri RWPH |
249 | MS pipe work for individual suction from common header, reducer, enlarger, inividual delivery piping of each pump and common delivery header up to Valve/flow meter and related works including bore in walls at following locations as -:- |
250 | AT DHEEMRI TPS |
251 | AT LOHARWA TPS |
252 | AT SHOBHALA JETMAL TPS |
253 | AT DHORIMANNA TPS |
254 | AT MANGLE KI BERI CPS |
255 | AT BERI GAON CPS |
256 | AT RATANPURA CPS |
257 | AT KADANARI CPS |
258 | AT KOSHALU CPS |
259 | AT KHADALI CPS |
260 | AT NOKHRA CPS |
261 | AT NIMBAL KOT CPS |
262 | AT GUDHAMALANI CPS |
263 | AT ADEL CPS |
264 | AT BHEDANA CPS |
265 | AT PIPRALI CPS |
266 | AT MISARI KI BERI CPS |
267 | AT MEETHIYA TALA CPS |
268 | AT KANHAIYA NAGAR CPS |
269 | AT DHEEMRI CPS |
270 | AT LOHARWA CPS |
271 | AT SHOBHALA JETMAL CPS |
272 | AT DHORIMANNA CPS |
273 | Manually operated PN 1.0 ratingsoft seated sluice valves with dismantling joints at intersection of CWR outlet with common suction header and individual suction of each pump at following locations:- |
274 | AT MANGLE KI BERI CPS |
275 | AT BERI GAON CPS |
276 | AT RATANPURA CPS |
277 | AT KADANARI CPS |
278 | AT KOSHALU CPS |
279 | AT KHADALI CPS |
280 | AT NOKHRA CPS |
281 | AT NIMBAL KOT CPS |
282 | AT GUDHAMALANI IPS-cum-CPS |
283 | AT ADEL IPS-cum-CPS |
284 | AT BHEDANA IPS-cum-CPS |
285 | AT PIPRALI CPS |
286 | AT MISARI KI BERI CPS |
287 | AT MEETHIYA TALA CPS |
288 | AT KANHAIYA NAGAR CPS |
289 | AT DHEEMRI CPS |
290 | AT LOHARWA CPS |
291 | AT SHOBHALA JETMAL CPS |
292 | AT DHORIMANNA CPS |
293 | Manually operated PN 1.0 ratingsoft seated sluice valves with dismantling jointsat intersection of CWR outlet with common suction header and individual suction of each pump at following locations:- |
294 | AT DHEEMRI TPS |
295 | AT LOHARWA TPS |
296 | AT SHOBHALA JETMAL TPS |
297 | AT DHORIMANNA TPS |
298 | Ductile Iron PN 1.6 rating Double Plate Check valves with Expansion Bellow Type Dismantling Joint on each pump delivery sideat following locations:- |
299 | AT GANDHAV RWPH |
300 | AT Dheemri RWPH |
301 | AT DHEEMRI TPS |
302 | AT DHEEMRI CPS |
303 | AT MANGLE KI BERI CPS |
304 | AT BERI GAON CPS |
305 | AT RATANPURA CPS |
306 | AT KADANARI CPS |
307 | AT KOSHALU CPS |
308 | AT KHADALI CPS |
309 | AT NOKHRA CPS |
310 | AT NIMBAL KOT CPS |
311 | AT GUDHAMALANI CPS |
312 | AT ADEL CPS |
313 | AT BHEDANA CPS |
314 | AT LOHARWA TPS |
315 | AT LOHARWA CPS |
316 | AT PIPRALI CPS |
317 | AT SHOBHALA JETMAL TPS |
318 | AT SHOBHALA JETMAL CPS |
319 | AT MISARI KI BERI CPS |
320 | AT DHORIMANNA TPS |
321 | AT DHORIMANNA CPS |
322 | AT MEETHIYA TALA CPS |
323 | AT KANHAIYA NAGAR CPS |
324 | Ductile IronPN 1.6 ratingElectrically operated Butterfly/ Soft seatedSluice valve with actuators oneach individual delivery of each pump side at following locations:- |
325 | AT GANDHAV RWPH |
326 | AT Dheemri RWPH |
327 | AT DHEEMRI CPS |
328 | AT DHEEMRI TPS |
329 | AT MANGLE KI BERI CPS |
330 | AT BERI GAON CPS |
331 | AT RATANPURA CPS |
332 | AT KADANARI CPS |
333 | AT KOSHALU CPS |
334 | AT KHADALI CPS |
335 | AT NOKHRA CPS |
336 | AT NIMBAL KOT CPS |
337 | AT GUDHAMALANI CPS |
338 | AT ADEL CPS |
339 | AT BHEDANA CPS |
340 | AT LOHARWA TPS |
341 | AT LOHARWA CPS |
342 | AT PIPRALI CPS |
343 | AT SHOBHALA JETMAL TPS |
344 | AT SHOBHALA JETMAL CPS |
345 | AT MISARI KI BERI CPS |
346 | AT DHORIMANNA TPS |
347 | AT DHORIMANNA CPS |
348 | AT MEETHIYA TALA CPS |
349 | AT KANHAIYA NAGAR CPS |
350 | PN 1.6 ratingManually operated soft seated sluice valves with expansion bellow type dismantling joints on individual delivery of each pump as well as on common delivery header at following locations:- |
351 | AT GANDHAV RWPH |
352 | AT Dheemri RWPH |
353 | AT DHEEMRI TPS |
354 | AT DHEEMRI CPS |
355 | AT MANGLE KI BERI CPS |
356 | AT BERI GAON CPS |
357 | AT RATANPURA CPS |
358 | AT KADANARI CPS |
359 | AT KOSHALU CPS |
360 | AT KHADALI CPS |
361 | AT NOKHRA CPS |
362 | AT NIMBAL KOT CPS |
363 | AT GUDHAMALANI CPS |
364 | AT ADEL CPS |
365 | AT BHEDANA CPS |
366 | AT LOHARWA TPS |
367 | AT LOHARWA CPS |
368 | AT PIPRALI CPS |
369 | AT SHOBHALA JETMAL TPS |
370 | AT SHOBHALA JETMAL CPS |
371 | AT MISARI KI BERI CPS |
372 | AT DHORIMANNA TPS |
373 | AT DHORIMANNA CPS |
374 | AT MEETHIYA TALA CPS |
375 | AT KANHAIYA NAGAR CPS |
376 | Vertical Turbine Pumps (1W+1S) with 0 .415 kV motor, Column pipe, shaft and other accessories complete at following location:- |
377 | At Gandhav RWPH |
378 | At Dheemri RWPH |
379 | HSC / End Suction type Centrifugal Pump sets (1W+1S) with LT 0.415 kV horizontal motor,base plates, Coupling, foundation bolts, accessories etc. on concrete foundation with accurate levellingand proper alignment completeat following locations:- |
380 | AT DHEEMRI TPS-cum-CPS |
381 | TO LOHARWA PS |
382 | TO BERI GAON PS |
383 | H.W DHEEMRI TO P-SR DHEEMRI CL-20 |
384 | H.W DHEEMRI TO P-SR GADEVI CL-22 |
385 | H.W DHEEMRI TO P-SR ALPURA CL-25, P-SR BHEEMGARH CL-24 |
386 | AT MANGLE KI BERI CPS |
387 | CPS-MANGLE KI BERI TO P-SR CHHOTU CL-39 |
388 | CPS-MANGLE KI BERI TO P-SR Shivpura CL-07, P-SR Neharo Ka Was CL-06 |
389 | CPS-MANGLE KI BERI TO P-SR AASUON KI DHANI CL-45, P-SR MANGLE KI BERICL-54, P-SR KHOOBRI BERI CL-47 |
390 | AT BERI GAON CPS |
391 | CPS-BERI GAON TO P-SR PALIYALI CL-17, P-SR GANDHAW KALAN CL-16 |
392 | CPS-BERI GAON TO P-SR RAMJI KA GOL PHANTA CL-23, P-SR PANWALI CL-15, P-SR SHIVAJI KA MANDIR CL-80, P-SR PANAL KI BERI CL-79, P-SR ROLI CL-21 |
393 | CPS-BERI GAON TO P-SR ROLI CL-21 |
394 | CPS-BERI GAON TO P-SR BERIGAON CL-14 |
395 | AT KADANARI CPS |
396 | CPS-KADNARI TO P-SR KADNARICL-57, P-SR THAVON KI DHANICL-58, P-SR LOONA KALA CL- 69, P-SR AMARPURA CL-68 |
397 | AT KOSHALU CPS |
398 | IPS-KOSHLOU TO P-SR KEHRANI SARANO KA TALACL-65, P-SR MEGWALON KI DHANI CL-36, P- SR NEERIYA NADACL-56, P-SR VISHNU MANDIR KA BASCL-59, P-SR ED AMARSINGH CL-60 |
399 | IPS-KOSHLOU TOP-SR BHALKHARI CL-71, P-SR MOTISARACL-70, P-SR PANYLA KALLACL-55 |
400 | IPS-KOSHLOU TO P-SR SARA JHOOND CL-63, P-SR SARA CL-61, P-SR BHATALA CL-62, P-SR KHUDALA CL-72 |
401 | AT KHADALI CPS |
402 | CPS-KHADALI CPS TO P-SR KHADALI CL-11 |
403 | CPS-KHADALI CPS TO P-SR BAND CL-52, P-SR ADARSH GOLIYA CL-41, P-SR RANASAR KHURD CL-53, P-SR BAKANI SARNON KI DHANI CL-42, |
404 | AT NOKHRA CPS |
405 | CPS NOKHRA TO P-SR ADARSH CHHOTU CL-40 |
406 | CPS NOKHRA TO P-SR DAUKIYO KI DHANI CL-44, P-SR ANKHIYA CL-50, P-SR HUKMANI KHOTON KI DHANI CL-43 |
407 | CPS NOKHRA TO P-SR NOKHRA CL-48, P-SR NEHRO KA TALA CL-49 & P-SR HUDON KA TALA CL- 51 |
408 | AT NIMBAL KOT CPS |
409 | CPS-NEEMBAL KOT TO P-SR MEETHIYAWAS CL-78, P-SR JOGASAR CL-77, P-SR POTLIYON KI DHANICL-75, P-SR PANANIYON KA TALA CL-76 |
410 | CPS-NEEMBAL KOT TO P-SR JANIYON KI DHANICL-33, P-SR KHARIYA KHURD CL-35 |
411 | AT GUDHAMALANI IPS-cum-CPS |
412 | IPS-GUDAMALANI TO P-CWR GUDAMALANI CL-30 |
413 | IPS-GUDAMALANI TO P-SR BORLI CL-13, P-SR BARASAN CL-12, P-SR MOKHWA CL-31, P-SR DABAD CL-29 |
414 | IPS-GUDAMALANI TO P-SR GORAMANIYON KI DHANI CL-9, P-SR NAGAR CL-8, P-SR DHANDHALWAS(DAULATPURA) CL-10, P-SR NAI UNDARI CL-73, P-SR JOONI UNDARI CL-46 |
415 | AT ADEL IPS-cum-CPS |
416 | IPS-ADEL TO CPS Nokhra |
417 | IPS-ADEL TO P-SR ADEL CL-37 |
418 | IPS-ADEL TO J-23, P-SR SAIYLON KA TALA CL-38 |
419 | AT BHEDANA IPS-cum-CPS |
420 | IPS-BHEDANA TO P-SR DHOBLI CL-67, P-SR PRABHU NAGARCL-64, P-SR TOONKIYACL-66 |
421 | IPS-BHEDANA TO P-SR AMLIYALA CL-74, P-SR SARSWATI NAGAR(BHEDANA) CL-18, P-SR LOONWA JAGEER CL-32 |
422 | IPS-BHEDANA TO P-SR DEONAGAR CL-19 |
423 | AT LOHARWA IPS-cum-CPS |
424 | TPS-LOHARWAS TO TPS-DHORIMANA & CPS-MISARI KI BERI |
425 | TPS-LOHARWAS TO TPS-SOBHALAJETMAL |
426 | IPS-LOHARWA TO P-SR LOHARWA CL-20 |
427 | IPS-LOHARWA TO P-SR ALAMSAR KHURD CL-33 |
428 | IPS-LOHARWA TO P-SR JAKHRON KI DHANI CL-12, P-SR SAIYON KA GOLIYACL-21, P-SR SANWARA CL-22 |
429 | IPS-LOHARWA TO P-SR SEELGAN CL-19, P-SR MOODHSAR CL-53, P-SR BHIMTHAL CL-18 |
430 | AT PIPRALI CPS |
431 | CPS-PIPRALI TO P-SR AASUPURA CL-49, P-SR PUNJABERI CL-43, P-SR PEEPRALI CL-50, P-SR KOTHALA CL-51 |
432 | AT SHOBHALA JETMAL IPS-cum-CPS |
433 | To CPS Meethiya Tala |
434 | IPS-SOBHALA JETMAL TO P-SR MEGWALO KA TALACL-7, P-SR BOOTH JETMAL CL-04, P-SR KHARDIYA CL-2 |
435 | IPS-SOBHALA JETMAL TO P-SR DHARMPURA CL-55, P-SR SHIV NAGARCL-36, P-SR LAXMANPURACL-35 |
436 | IPS-SOBHALA JETMAL TO P-SR ROHILA CL-41, P-SR SIYAGON KI DHANICL-6 |
437 | IPS-SOBHALA JETMAL TO P-SR SOBHALA JETAMAL CL-5 |
438 | IPS-SOBHALA JETMAL TO P-SR BHOMIYAN JI KA THAN (KOSHLE KI DHANI) CL-34, P-SR KALAPURACL-31, P-SR DUDAPUR (RELO KI BERI) CL-32, P-SR VINAYAK NAGAR CL-42 |
439 | AT MISARI KI BERI CPS |
440 | CPS-MISARI KI BERI TO P-SR RAWON KI BERI CL-15, P-SR BHILON KI BASTI CL-14,P-SR SURTE KI BERI CL-38, P-SR MUKNE KA TALA CL-37 |
441 | CPS-MISARI KI BERI TO P-SR MISARI KI BERI CL-13 |
442 | CPS-MISARI KI BERI TO P-SR BHILON KI DHANI KALAN CL-25, P-SRKHARAD(SUTHARO KI DHANI) CL-27 |
443 | AT DHORIMANNA IPS-cum-CPS |
444 | TPS-DHORIMANA TO CPS-KANAHAIYA NAGAR |
445 | IPS-DHORIMANNA TO CWR-DHORIMANNA (CT) CL-26 & P-SR NEDI NARI CL-28 |
446 | IPS-DHORIMANNA TO P-SR SUDABERI CL-29, P-SR DER CL-52 |
447 | IPS-DHORIMANNA TO P-SR MEETHRA KHURD CL-16, P-SR KATARLA KHILERIYAN CL-30, P-SR LOLO KI BERI CL-17 |
448 | AT MEETHIYA TALA CPS |
449 | CPS-MEETHIYA TALA TO P-SR EKLAVYA NAGARCL-39, P-SR SAWAMIYAN KI BERICL-40, P-SR MANGTA CL-1, P-SR MEHGWALO KA TALACL-56 |
450 | CPS-MEETHIYA TALA TO P-SR ROOGPURA CL-48, P-SR BACHHRAOO CL-47 |
451 | CPS-MEETHIYA TALA TO P-SR BILALANI CL-46, P-SR PINGALPURA(BANDA BERA)CL-45, P-SR MITHABERACL-44 |
452 | CPS-MEETHIYA TALA TO P-SR MEETHIYA TALACL-3 |
453 | AT KANHAIYA NAGAR CPS |
454 | CPS-KANAHAIYA NAGAR TO P-SR KANHAIYA NAGAR CL-11 |
455 | CPS-KANAHAIYA NAGAR TO P-SR KOJA CL-10, P-SR HIRKRN KA THAN CL-54 |
456 | CPS-KANAHAIYA NAGAR TO P-SR MUSALMANON KI DHANICL-24, P-SR RANASAR KALAN CL-8, P- SR BHALISAR CL-23, P-SR JANIYO KI BERI CL-9 |
457 | AT RATANPURA CPS |
458 | CPS-RATANPURA TO P-SR KOODA CL-26 |
459 | CPS-RATANPURA TO P-SR RATANPURA CL-27, P-SR DEDAWAS JAGEER CL-28 |
460 | CPS-RATANPURA TO P-SR BHAKHARPURA CL-3, P-SR KHARWA CL-5, P-SR BAROODI CL-4, P-SR SIDHASAWA HARNIYAN CL-1, , P-SR SALU KI DHANI(ARATBAW) CL-2 |
461 | Overhead Treverssing Crane Semi Electrically operated of suitable capacity along with MS girders, MS rails, electric hoist, chain etc. at following locations:- |
462 | AT GANDHAV RWPH |
463 | AT DHEEMRI TPS-cum-CPS |
464 | AT MANGLE KI BERI CPS |
465 | AT BERI GAON CPS |
466 | AT RATANPURA CPS |
467 | AT KADANARI CPS |
468 | AT KOSHALU CPS |
469 | AT KHADALI CPS |
470 | AT NOKHRA CPS |
471 | AT NIMBAL KOT CPS |
472 | AT LOHARWA IPS-cum-CPS |
473 | AT PIPRALI CPS |
474 | AT SHOBHALA JETMAL IPS-cum-CPS |
475 | AT MISARI KI BERI CPS |
476 | AT DHORIMANNA IPS-cum-CPS |
477 | AT MEETHIYA TALA CPS |
478 | AT KANHAIYA NAGAR CPS |
479 | Submersible Drain pumps of Minimum 3 m3/hr capacity @ 10 meters head at following locations:- |
480 | AT DHEEMRI TPS-cum-CPS |
481 | AT MANGLE KI BERI CPS |
482 | AT BERI GAON CPS |
483 | AT RATANPURA CPS |
484 | AT KADANARI CPS |
485 | AT KOSHALU CPS |
486 | AT KHADALI CPS |
487 | AT NOKHRA CPS |
488 | AT NIMBAL KOT CPS |
489 | AT LOHARWA IPS-cum-CPS |
490 | AT PIPRALI CPS |
491 | AT SHOBHALA JETMAL IPS-cum-CPS |
492 | AT MISARI KI BERI CPS |
493 | AT DHORIMANNA IPS-cum-CPS |
494 | AT MEETHIYA TALA CPS |
495 | AT KANHAIYA NAGAR CPS |
496 | Continuous type Electro chlorinator (1 working+1 standby) of suitable capacity including all required pipe fitting, accessories, valves, Brine Tank (HDPE material) of required capacity, level and Temperature sensors, pumps, Rotameter, Electrolyser, Hypo tank (HDPE Material), Blower, acid tank and pump, DC rectifier cum Control Panel and all required power and control cables complete at following locations:- |
497 | AT GUDHAMALANI |
498 | AT ADEL |
499 | AT BHEDANA |
500 | AT MANGLE KI BERI |
501 | AT BERI GAON |
502 | AT RATANPURA |
503 | AT KADANARI |
504 | AT KOSHALU |
505 | AT KHADALI |
506 | AT NOKHRA |
507 | AT NIMBAL KOT |
508 | AT LOHARWA |
509 | AT PIPRALI |
510 | AT SHOBHALA JETMAL |
511 | AT MISARI KI BERI |
512 | AT DHORIMANNA |
513 | AT MEETHIYA TALA |
514 | AT KANHAIYA NAGAR |
515 | Electrical WORKS:-Design, Provide , Installation, Testing, Commissioningfor following as per Employer requirement and Specification (FromJdVVNL End toMotor Panel) |
516 | Distribution Transformers (1+1) including all other accessories and protection devices complete at following locations with Minimum Rating:- |
517 | AT GANDHAV RWPH 33/0.415 KV |
518 | AT DHEEMRI TPS-cum-CPS 33/0.415 KV |
519 | AT LOHARWA IPS-cum-CPS 33/0.415 KV |
520 | AT SHOBHALA JETMAL IPS-cum-CPS 33/0.415 KV |
521 | AT DHORIMANNA IPS-cum-CPS 33/0.415 KV |
522 | AT GUDAMALANI CPS 33/0.415 KV |
523 | AT ADEL CPS 33/0.415 KV |
524 | AT BHEDANA CPS 33/0.415 KV |
525 | AT MANGLE KI BERI CPS 11/0.415 KV |
526 | AT BERI GAON CPS 11/0.415 KV |
527 | AT RATANPURA CPS 11/0.415 KV |
528 | AT KADANARI CPS 11/0.415 KV |
529 | AT KOSHALU CPS 11/0.415 KV |
530 | AT KHADALI CPS 11/0.415 KV |
531 | AT NOKHRA CPS 11/0.415 KV |
532 | AT NIMBAL KOT CPS 11/0.415 KV |
533 | AT PIPRALI CPS 11/0.415 KV |
534 | AT MISARI KI BERI CPS 11/0.415 KV |
535 | AT MEETHIYA TALA CPS 11/0.415 KV |
536 | AT KANHAIYA NAGAR CPS 11/0.415 KV |
537 | 33 KV, 630 Amp Switch board ( HT VCB panel ) withall required protection, equipment, Instrument, accessories, battery with charger, DCDBetc for 33/.44 KV substation atFollowing Locations:- |
538 | AT GANDHAV RWPH |
539 | AT DHEEMRI TPS-cum-CPS |
540 | AT LOHARWA IPS-cum-CPS |
541 | AT SHOBHALA JETMAL IPS-cum-CPS |
542 | AT DHORIMANNA IPS-cum-CPS |
543 | AT GUDAMALANI CPS |
544 | AT BHEDANA CPS |
545 | AT ADEL CPS |
546 | 11 KV, 630 Amp,Out Door type Ring Main Unit ( RMU ) with 1 Incomer and 2 out going VCB withall required protection, equipment, Instrument, accessories, battery with charger, DCDBetc for 11/.44 KV substation atFollowing Locations:- |
547 | AT MANGLE KI BERI |
548 | AT BERI GAON CPS |
549 | AT RATANPURA CPS |
550 | AT KADANARI CPS |
551 | AT KOSHALU CPS |
552 | AT KHADALI CPS |
553 | AT NOKHRA CPS |
554 | AT NIMBAL KOT CPS |
555 | AT PIPRALI CPS |
556 | AT MISARI KI BERI CPS |
557 | AT MEETHIYA TALA CPS |
558 | AT KANHAIYA NAGAR CPS |
559 | XLPE insulated H.T.cable for working voltage 33 KV from JdVVNL end point to HT panel and from Panel to transformer along with all necessary accessories,complete for following locations:- |
560 | AT GANDHAV RWPH |
561 | AT DHEEMRI TPS-cum-CPS |
562 | AT LOHARWA IPS-cum-CPS |
563 | AT SHOBHALA JETMAL IPS-cum-CPS |
564 | AT DHORIMANNA IPS-cum-CPS |
565 | AT GUDAMALANI CPS |
566 | AT BHEDANA CPS |
567 | AT ADEL CPS |
568 | XLPE insulated H.T.cable for working voltage 11 KV from JVVNL end point to RMU and from RMU to transformer along with all necessary accessories, complete for following locations:- |
569 | AT MANGLE KI BERI CPS |
570 | AT BERI GAON CPS |
571 | AT RATANPURA CPS |
572 | AT KADANARI CPS |
573 | AT KOSHALU CPS |
574 | AT KHADALI CPS |
575 | AT NOKHRA CPS |
576 | AT NIMBAL KOT CPS |
577 | AT PIPRALI CPS |
578 | AT MISARI KI BERI CPS |
579 | AT MEETHIYA TALA CPS |
580 | AT KANHAIYA NAGAR CPS |
581 | Maintenance free gel earthing for Electricalsub stations (No. of earthings as per design requirements)as at following locations:- |
582 | AT GANDHAV RWPH |
583 | AT DHEEMRI TPS-cum-CPS |
584 | AT LOHARWA IPS-cum-CPS |
585 | AT SHOBHALA JETMAL IPS-cum-CPS |
586 | AT DHORIMANNA IPS-cum-CPS |
587 | AT MANGLE KI BERI CPS |
588 | AT GUDAMALANI CPS |
589 | AT ADEL CPS |
590 | AT BHEDANA CPS |
591 | AT BERI GAON CPS |
592 | AT RATANPURA CPS |
593 | AT KADANARI CPS |
594 | AT KOSHALU CPS |
595 | AT KHADALI CPS |
596 | AT NOKHRA CPS |
597 | AT NIMBAL KOT CPS |
598 | AT PIPRALI CPS |
599 | AT MISARI KI BERI CPS |
600 | AT MEETHIYA TALA CPS |
601 | AT KANHAIYA NAGAR CPS |
602 | All civil works related to electric sub station including transformer foundation withdivide wall, oil collection sump, Piping, Chain link fencing with gates, Spreading of gravel in the sub Station areas, Civil works required for laying of cables( Trenching/ Trey) etc, for following location |
603 | AT GANDHAV RWPH |
604 | AT DHEEMRI TPS-cum-CPS |
605 | AT LOHARWA IPS-cum-CPS |
606 | AT SHOBHALA JETMAL IPS-cum-CPS |
607 | AT DHORIMANNA IPS-cum-CPS |
608 | AT MANGLE KI BERI CPS |
609 | AT GUDAMALANI CPS |
610 | AT ADEL CPS |
611 | AT BHEDANA CPS |
612 | AT BERI GAON CPS |
613 | AT RATANPURA CPS |
614 | AT KADANARI CPS |
615 | AT KOSHALU CPS |
616 | AT KHADALI CPS |
617 | AT NOKHRA CPS |
618 | AT NIMBAL KOT CPS |
619 | AT PIPRALI CPS |
620 | AT MISARI KI BERI CPS |
621 | AT MEETHIYA TALA CPS |
622 | AT KANHAIYA NAGAR CPS |
623 | Design, Provide , Installation, Testing, Commissioningfor following as per Employer requirement and Specification (Onwards to Motor Panel) |
624 | LT switchgear housing two incomers ACBs,MCCBs,relays,metering system,CT,PT,Bus Bar,Bus Couplers etc.with requisite numbers of outgoing cubical to have Motor control unit with starters for all LT motors of main pumps, for electric actuators and Hoist, Main lighting distribution panel for inside as well as out side pump room, welding socket, spare cubicals,switchgear for DG system, complete in all respect for following location . |
625 | AT DHEEMRI RWPH |
626 | AT GANDHAV RWPH |
627 | AT DHEEMRI TPS |
628 | AT DHEEMRI CPS |
629 | AT LOHARWA TPS |
630 | AT LOHARWA CPS |
631 | AT SHOBHALA JETMAL TPS |
632 | AT SHOBHALA JETMAL CPS |
633 | AT DHORIMANNA TPS |
634 | AT DHORIMANNA CPS |
635 | AT MANGLE KI BERI CPS |
636 | AT GUDAMALANI CPS |
637 | AT ADEL CPS |
638 | AT BHEDANA CPS |
639 | AT BERI GAON CPS |
640 | AT RATANPURA CPS |
641 | AT KADANARI CPS |
642 | AT KOSHALU CPS |
643 | AT KHADALI CPS |
644 | AT NOKHRA CPS |
645 | AT NIMBAL KOT CPS |
646 | AT PIPRALI CPS |
647 | AT MISARI KI BERI CPS |
648 | AT MEETHIYA TALA CPS |
649 | AT KANHAIYA NAGAR CPS |
650 | APFC Panel with Capacitor Bank at following Pumping Station |
651 | AT DHEEMRI RWPH |
652 | AT GANDHAV RWPH |
653 | AT DHEEMRI TPS |
654 | AT DHEEMRI CPS |
655 | AT LOHARWA TPS |
656 | AT LOHARWA CPS |
657 | AT SHOBHALA JETMAL TPS |
658 | AT SHOBHALA JETMAL CPS |
659 | AT DHORIMANNA TPS |
660 | AT DHORIMANNA CPS |
661 | AT MANGLE KI BERI CPS |
662 | AT GUDAMALANI CPS |
663 | AT ADEL CPS |
664 | AT BHEDANA CPS |
665 | AT BERI GAON CPS |
666 | AT RATANPURA CPS |
667 | AT KADANARI CPS |
668 | AT KOSHALU CPS |
669 | AT KHADALI CPS |
670 | AT NOKHRA CPS |
671 | AT NIMBAL KOT CPS |
672 | AT PIPRALI CPS |
673 | AT MISARI KI BERI CPS |
674 | AT MEETHIYA TALA CPS |
675 | AT KANHAIYA NAGAR CPS |
676 | Local push button station for pump motors, actuators, HoistAt all 21 locations of Pumping Station |
677 | AT DHEEMRI RWPH |
678 | AT GANDHAV RWPH |
679 | AT DHEEMRI TPS |
680 | AT DHEEMRI CPS |
681 | AT LOHARWA TPS |
682 | AT LOHARWA CPS |
683 | AT SHOBHALA JETMAL TPS |
684 | AT SHOBHALA JETMAL CPS |
685 | AT DHORIMANNA TPS |
686 | AT DHORIMANNA CPS |
687 | AT MANGLE KI BERI CPS |
688 | AT GUDAMALANI CPS |
689 | AT ADEL CPS |
690 | AT BHEDANA CPS |
691 | AT BERI GAON CPS |
692 | AT RATANPURA CPS |
693 | AT KADANARI CPS |
694 | AT KOSHALU CPS |
695 | AT KHADALI CPS |
696 | AT NOKHRA CPS |
697 | AT NIMBAL KOT CPS |
698 | AT PIPRALI CPS |
699 | AT MISARI KI BERI CPS |
700 | AT MEETHIYA TALA CPS |
701 | AT KANHAIYA NAGAR CPS |
702 | 110V DC system with batteries, battery charger, DC DB in panel to operate spring charging motors and LED supply on LT panel At followingpumping station . |
703 | AT DHEEMRI RWPH |
704 | AT GANDHAV RWPH |
705 | AT DHEEMRI TPS |
706 | AT DHEEMRI CPS |
707 | AT LOHARWA TPS |
708 | AT LOHARWA CPS |
709 | AT SHOBHALA JETMAL TPS |
710 | AT SHOBHALA JETMAL CPS |
711 | AT DHORIMANNA TPS |
712 | AT DHORIMANNA CPS |
713 | AT MANGLE KI BERI CPS |
714 | AT GUDAMALANI CPS |
715 | AT ADEL CPS |
716 | AT BHEDANA CPS |
717 | AT BERI GAON CPS |
718 | AT RATANPURA CPS |
719 | AT KADANARI CPS |
720 | AT KOSHALU CPS |
721 | AT KHADALI CPS |
722 | AT NOKHRA CPS |
723 | AT NIMBAL KOT CPS |
724 | AT PIPRALI CPS |
725 | AT MISARI KI BERI CPS |
726 | AT MEETHIYA TALA CPS |
727 | AT KANHAIYA NAGAR CPS |
728 | LT cable withAccessories, cable trays/Trenchingfor motors and all Electrical equipments to be provided in Head works at FollowingLocations |
729 | AT DHEEMRI RWPH |
730 | AT GANDHAV RWPH |
731 | AT DHEEMRI TPS |
732 | AT DHEEMRI CPS |
733 | AT LOHARWA TPS |
734 | AT LOHARWA CPS |
735 | AT SHOBHALA JETMAL TPS |
736 | AT SHOBHALA JETMAL CPS |
737 | AT DHORIMANNA TPS |
738 | AT DHORIMANNA CPS |
739 | AT MANGLE KI BERI CPS |
740 | AT GUDAMALANI CPS |
741 | AT ADEL CPS |
742 | AT BHEDANA CPS |
743 | AT BERI GAON CPS |
744 | AT RATANPURA CPS |
745 | AT KADANARI CPS |
746 | AT KOSHALU CPS |
747 | AT KHADALI CPS |
748 | AT NOKHRA CPS |
749 | AT NIMBAL KOT CPS |
750 | AT PIPRALI CPS |
751 | AT MISARI KI BERI CPS |
752 | AT MEETHIYA TALA CPS |
753 | AT KANHAIYA NAGAR CPS |
754 | Exhaust Fans, Pedestal type air circulator, other ventilating arrangement for Following Pump Station |
755 | AT GANDHAV RWPH |
756 | AT DHEEMRI TPS-cum-CPS |
757 | AT LOHARWA IPS-cum-CPS |
758 | AT SHOBHALA JETMAL IPS-cum-CPS |
759 | AT DHORIMANNA IPS-cum-CPS |
760 | AT MANGLE KI BERI CPS |
761 | AT GUDAMALANI CPS |
762 | AT ADEL CPS |
763 | AT BHEDANA CPS |
764 | AT BERI GAON CPS |
765 | AT RATANPURA CPS |
766 | AT KADANARI CPS |
767 | AT KOSHALU CPS |
768 | AT KHADALI CPS |
769 | AT NOKHRA CPS |
770 | AT NIMBAL KOT CPS |
771 | AT PIPRALI CPS |
772 | AT MISARI KI BERI CPS |
773 | AT MEETHIYA TALA CPS |
774 | AT KANHAIYA NAGAR CPS |
775 | Earthing system for LV systems and motors installed in the contract in the Head works At |
776 | AT DHEEMRI RWPH |
777 | AT GANDHAV RWPH |
778 | AT DHEEMRI TPS-cum-CPS |
779 | AT LOHARWA IPS-cum-CPS |
780 | AT SHOBHALA JETMAL IPS-cum-CPS |
781 | AT DHORIMANNA IPS-cum-CPS |
782 | AT MANGLE KI BERI CPS |
783 | AT GUDAMALANI CPS |
784 | AT ADEL CPS |
785 | AT BHEDANA CPS |
786 | AT BERI GAON CPS |
787 | AT RATANPURA CPS |
788 | AT KADANARI CPS |
789 | AT KOSHALU CPS |
790 | AT KHADALI CPS |
791 | AT NOKHRA CPS |
792 | AT NIMBAL KOT CPS |
793 | AT PIPRALI CPS |
794 | AT MISARI KI BERI CPS |
795 | AT MEETHIYA TALA CPS |
796 | AT KANHAIYA NAGAR CPS |
797 | Diesel generating set of respective minimumcapacity including all associated accessories for lighting load At following locations:- |
798 | AT GANDHAV RWPH ( 7.5 KVA) |
799 | AT LOHARWA IPS-cum-CPS (7.5 KVA) |
800 | AT SHOBHALA JETMAL IPS-cum-CPS ( 7.5 KVA) |
801 | AT DHORIMANNA IPS-cum-CPS ( 7.5 KVA) |
802 | AT MANGLE KI BERI CPS ( 5 KVA) |
803 | AT GUDAMALANI CPS ( 5 KVA) |
804 | AT ADEL CPS ( 5 KVA) |
805 | AT BHEDANA CPS ( 5 KVA) |
806 | AT BERI GAON CPS (5 KVA) |
807 | AT RATANPURA CPS ( 5 KVA) |
808 | AT KADANARI CPS ( 5 KVA) |
809 | AT KOSHALU CPS ( 5 KVA) |
810 | AT KHADALI CPS ( 5 KVA) |
811 | AT NOKHRA CPS ( 5 KVA) |
812 | AT NIMBAL KOT CPS ( 5 KVA) |
813 | AT PIPRALI CPS ( 5 KVA) |
814 | AT MISARI KI BERI CPS ( 5 KVA) |
815 | AT MEETHIYA TALA CPS ( 5 KVA) |
816 | AT KANHAIYA NAGAR CPS ( 5 KVA) |
817 | AT DHEEMARI CAMPUS ( 25 KVA) |
818 | BILL 5- Instrumentation |
819 | Setting up of Master Control Station (MCS) : Complete Automization, PLC and SCADA system including central processing unit, memory unit, Input/Output modules, requisite hardware and software, Communication system, Instrument Control Panel (I.C.P.) / Control Desk, (MMI) consisting of required Personal Computers with colour monitors, printers, UPS, all transducers and transmittersetc. SCADA software and its installation with required software, complete in all respect including air conditioners at WTP DheemriAdministrative Buildingas per General and Particular Specifications and Employer"s requirement |
820 | Setting up of Local Control Station (LCS): Complete Automization, PLC and SCADA system including central processing unit, memory unit, Input/Output modules, requisite hardware and software,Instrument Control Panel (I.C.P.) / Control Desk, MMI), consisting of one Personal Computer with printers, UPS, all transducers and transmitters, communication or internet Systemetc. SCADA software and its installation with required software complete in all respect at following locations as per General and Particular Specifications and Employer"s requirement |
821 | AT GANDHAV RWPH |
822 | AT LOHARWA |
823 | AT SHOBHALA JETMAL |
824 | AT DHORIMANNA |
825 | AT MANGLE KI BERI |
826 | AT GUDAMALANI |
827 | AT ADEL |
828 | AT BHEDANA |
829 | AT BERI GAON |
830 | AT RATANPURA |
831 | AT KADANARI |
832 | AT KOSHALU |
833 | AT KHADALI |
834 | AT NOKHRA |
835 | AT NIMBAL KOT |
836 | AT PIPRALI |
837 | AT MISARI KI BERI |
838 | AT MEETHIYA TALA |
839 | AT KANHAIYA NAGAR |
840 | At BARMER |
841 | Setting of remote Station and instrumentation control panel including all necessary hardware and software, instrumentation and control cable of LT power Cabling, LT Panel, Battery backup and UPS with 2 hrs battery backup complete for transferring the data as well as operation and control through SCADA of Flow Control Valves from Local/Master control Station (These are such where power connection is going to be available viz. near inlet of ESR having FCV). |
842 | Setting of remote Station including all necessary hardware and software, instrumentation, Battery backup complete for transferring the data to LCS and MCS (These are such where power connection is not going to be available viz. near inlet of ESR not having FCV plus Village Transfer Chambers). |
843 | Providing, Installation, testing, commissioning of Following Instrument as per Employer requirement and Specifications:- |
844 | for the WTP |
845 | Ultrasonic flow meters with transmitterfor inlet and outlet channels with all accessories |
846 | Bulk flow meters for air pipe and wash water pipe with all accessories |
847 | Mechanical flow measuring system withall accessories at the parshall flume |
848 | Ultrasonic type level sensor, transmitter with switch in the sump for atomisation of backwash pump. |
849 | Ultrasonic type level sensor,transmitter with level switch in backwash tank for atomisation of backwash pump |
850 | External cage type magnetic level sensors, transmit orwith switches in all solution tanks of Alum/PAC, lime and sludge thickening compound for automisationof dosing pumps |
851 | Sensors , Transmitter forDifferential Head across Filter Beds |
852 | PH meter with transmitterfor continuous monitoring at inlet and outlet |
853 | Continuous turbidity meter withtransmitter at inlet and outlet |
854 | Continuous Residual Chlorine sensorwith transmit or at the outlet |
855 | Portable pH meter, Chlorine Sensor and turbidity meters |
856 | IACC Panel with a automation components such as PLC and associated Digital Input/output subsystems, power supply unit, switches, indicators etc., along with Local SCADA Systemat following locations:- |
857 | AT GANDHAV RWPH |
858 | AT DHEEMRI |
859 | AT MANGLE KI BERI CPS |
860 | AT BERI GAON CPS |
861 | AT RATANPURA CPS |
862 | AT KADANARI CPS |
863 | AT KOSHALU CPS |
864 | AT KHADALI CPS |
865 | AT NOKHRA CPS |
866 | AT NIMBAL KOT CPS |
867 | AT GUDHAMALANI IPS-cum-CPS |
868 | AT ADEL IPS-cum-CPS |
869 | AT BHEDANA IPS-cum-CPS |
870 | AT LOHARWA IPS-cum-CPS |
871 | AT PIPRALI CPS |
872 | AT SHOBHALA JETMAL IPS-cum-CPS |
873 | AT MISARI KI BERI CPS |
874 | AT DHORIMANNA IPS-cum-CPS |
875 | AT MEETHIYA TALA CPS |
876 | AT KANHAIYA NAGAR CPS |
877 | At BARMER |
878 | Control cables, cable trays, support, Accessories, Glands, Work tocompletein all respectat following locations:- |
879 | AT GANDHAV RWPH |
880 | AT DHEEMRI |
881 | AT MANGLE KI BERI CPS |
882 | AT BERI GAON CPS |
883 | AT RATANPURA CPS |
884 | AT KADANARI CPS |
885 | AT KOSHALU CPS |
886 | AT KHADALI CPS |
887 | AT NOKHRA CPS |
888 | AT NIMBAL KOT CPS |
889 | AT GUDHAMALANI IPS-cum-CPS |
890 | AT ADEL IPS-cum-CPS |
891 | AT BHEDANA IPS-cum-CPS |
892 | AT LOHARWA IPS-cum-CPS |
893 | AT PIPRALI CPS |
894 | AT SHOBHALA JETMAL IPS-cum-CPS |
895 | AT MISARI KI BERI CPS |
896 | AT DHORIMANNA IPS-cum-CPS |
897 | AT MEETHIYA TALA CPS |
898 | AT KANHAIYA NAGAR CPS |
899 | At BARMER |
900 | UPS / Invertors with 2 hrs battery backup to supply power to all Instrumentation system, completeat following locations:- |
901 | AT GANDHAV RWPH |
902 | AT DHEEMRI |
903 | AT MANGLE KI BERI CPS |
904 | AT BERI GAON CPS |
905 | AT RATANPURA CPS |
906 | AT KADANARI CPS |
907 | AT KOSHALU CPS |
908 | AT KHADALI CPS |
909 | AT NOKHRA CPS |
910 | AT NIMBAL KOT CPS |
911 | AT GUDHAMALANI IPS-cum-CPS |
912 | AT ADEL IPS-cum-CPS |
913 | AT BHEDANA IPS-cum-CPS |
914 | AT LOHARWA IPS-cum-CPS |
915 | AT PIPRALI CPS |
916 | AT SHOBHALA JETMAL IPS-cum-CPS |
917 | AT MISARI KI BERI CPS |
918 | AT DHORIMANNA IPS-cum-CPS |
919 | AT MEETHIYA TALA CPS |
920 | AT KANHAIYA NAGAR CPS |
921 | At BARMER |
922 | Pressure Gauges at individual delivery and Headerat following Pumping Stationlocations:- |
923 | AT DHEEMARIRWPH |
924 | AT GANDHAV RWPH |
925 | AT DHEEMRI TPS-cum-CPS |
926 | AT MANGLE KI BERI CPS |
927 | AT BERI GAON CPS |
928 | AT RATANPURA CPS |
929 | AT KADANARI CPS |
930 | AT KOSHALU CPS |
931 | AT KHADALI CPS |
932 | AT NOKHRA CPS |
933 | AT NIMBAL KOT CPS |
934 | AT GUDHAMALANI IPS-cum-CPS |
935 | AT ADEL IPS-cum-CPS |
936 | AT BHEDANA IPS-cum-CPS |
937 | AT LOHARWA IPS-cum-CPS |
938 | AT PIPRALI CPS |
939 | AT SHOBHALA JETMAL IPS-cum-CPS |
940 | AT MISARI KI BERI CPS |
941 | AT DHORIMANNA IPS-cum-CPS |
942 | AT MEETHIYA TALA CPS |
943 | AT KANHAIYA NAGAR CPS |
944 | Ultrasonic level indicators with Sensor andSwitches atsump,Pressure Sensors, Transmitters and Switches on delivery header, Temperature sensors with transmitterfor motors, with all required components and associated erection hardware as well as accessories as per the requirements at following Pumping Stationlocations:- |
945 | AT DHEEMARIRWPH |
946 | AT GANDHAV RWPH |
947 | AT DHEEMRI TPS-cum-CPS |
948 | AT MANGLE KI BERI CPS |
949 | AT BERI GAON CPS |
950 | AT RATANPURA CPS |
951 | AT KADANARI CPS |
952 | AT KOSHALU CPS |
953 | AT KHADALI CPS |
954 | AT NOKHRA CPS |
955 | AT NIMBAL KOT CPS |
956 | AT GUDHAMALANI IPS-cum-CPS |
957 | AT ADEL IPS-cum-CPS |
958 | AT BHEDANA IPS-cum-CPS |
959 | AT LOHARWA IPS-cum-CPS |
960 | AT PIPRALI CPS |
961 | AT SHOBHALA JETMAL IPS-cum-CPS |
962 | AT MISARI KI BERI CPS |
963 | AT DHORIMANNA IPS-cum-CPS |
964 | AT MEETHIYA TALA CPS |
965 | AT KANHAIYA NAGAR CPS |
966 | FOR RESERVOIRS |
967 | Ultrasonic Level Indicator, transmitter, Sensor with all required components and associated erection hardware as well as accessoriesat following CWR locations:- |
968 | AT BERI GAON |
969 | AT KHADALI |
970 | AT NEEMBLI KOT |
971 | AT MANGLE KI BERI |
972 | AT NOKHRA |
973 | AT RATANPURA |
974 | AT Dhorimanna |
975 | AT Meethiya Tala |
976 | AT Shobhala Jetmal |
977 | AT Misari Ki Beri |
978 | AT Kanhaiya Nagar |
979 | AT Loharwa |
980 | AT Dheemari HW |
981 | AT ESRs |
982 | Electro-magnetic flow meters, transmitter, flow Integrator ( Digital display in Instrument Panel in Control Room) with required specials, fittings, supports etc.. complete in all respectof following NB:- |
983 | 500 DN |
984 | 450 DN |
985 | 350 DN |
986 | 300 DN |
987 | 250 DN |
988 | 200 DN |
989 | 150 DN |
990 | 125 DN |
991 | 100 DN |
992 | 80 DN |
993 | Battery Operated Woltman type In-Line flow meters with GSM/GPRS based communication model, battery with accessories, fittings, valves (upstream and downstream to the Flow meter), dismantling joints, Air valves, specials, pressure gauge, anchor block, supports,complete in all respect at all VTC (Size of flow meters shall vary from 80mm to 200 mm as per minimum flow velocity requirement of flow meter) |
994 | BILL 6- VILLAGE DISTRIBUTION |
995 | Survey, Design, Construction, Testing, Commissioningof circular RCC Clear Water reservoirs includingDI D/F inlet with manually operated Sluice Valve, dismantling joints, outlet with flange and blind flange, overflow with requiredpiping up to thechamber and up to storm water drain, washout pipe with sluice valves, construction of chambers complete in all respect of various capacitiesfor village Distribution as per Employer requirement and General Specification |
996 | 20 KL to 300 KL |
997 | Providing, installation, testing and commissioning of AC submersible pump sets with HDPE/GI pipe fittings and inbuilt or individual solar pump controllerwith Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps. Solar pumpshall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope. Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switchbe provided. The cable shall be ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date. The entire work shall be executed as per technical specification and direction of Engineer in charge. |
998 | Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area,MS fabricated structure 120 micron hot dip galvanized iron, fencing, showing arrangement of panel in available space and installation ofPV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document. |
999 | Construction of Pump House in Stone/Brick Masonry of min. 2.5m x 2.5m size for installation ofsolar pump andpaneletc complete in all respects as per Employer requirement and General Specification. |
1000 | Providing Household Tap Connectionas per technical specifications and approved drawings and as per relevant IS code (amended up to date) from HDPE pipe line by using PP integrated Saddle with in- built flow control valve made out by SS OR from uPVC/DI/AC/MS/GI pipe line by using PVC/MS Saddle piece with in-built flow control valve up to consumer meter/premises (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil, depositing and refilling of pit and jhiri with watering and ramming /compacting in layers and disposal of surplus excavated soil, providing and fixing of all fitting includingelectro fusion saddle piece, gunmetal ferrule 4 mm, GM full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings up to 6m in the premises for fixing a tap / meterbox, including accessories with flushing, cleaning, disinfecting and testing of pipeline complete required for making of service connection in all respect including road cutting and restoration, as per General and Particular specifications, and Employer"s requirement. It also includes P&F one Bib Cock (IS 8931 Mark) per household of superior quality of brass 400 gms, 15 mm nominal bore. |
1001 | BILL 7 - Civil AND ANCILLARY WORKS |
1002 | Construction of Office Building (Minimum Area 2500 Sqft) with furniture at GUDAMALANI HW as per Employer requirement, Specification and tender drawings. |
1003 | Construction of J-2 Type Set (Twin quarter) as per Employer requirement, Specification and tender drawingsat Mangle Ki Beri, Beri Gaon, Ratanpura, Khadali, Nokhra, Nimbal Kot, Kadanari, koshlu, Loharwa, Piprali, Shobala Jetmal, Misari Ki Beri, Dhorimanna, Meethiya Tala and Kanhaiya Nagar |
1004 | Campus area Development Works bylandscaping, Horticulture, Drainage, External campus lightingetc as per Employer requirement and Specification at following Campuses:- |
1005 | AT GANDHAV RWPH |
1006 | AT DHEEMRIHead Works |
1007 | AT LOHARWA |
1008 | AT SHOBHALA JETMAL |
1009 | AT DHORIMANNA |
1010 | AT MANGLE KI BERI |
1011 | AT BERI GAON |
1012 | AT RATANPURA |
1013 | AT KHADALI |
1014 | AT NOKHRA |
1015 | AT NIMBAL KOT |
1016 | AT PIPRALI |
1017 | AT MISARI KI BERI |
1018 | AT MEETHIYA TALA CPS |
1019 | AT KANHAIYA NAGAR CPS |
1020 | Construction of Boundary wall, installation of MSGates (Man and Animal Obstruct with Minimum Weight 450 Kg ) and Approach Roads as per Employer requirement and Specification for various PS head works, ESR campuses, VD CWRs etc. |
1021 | Boundary Wall |
1022 | MS Gates |
1023 | Cement Concrete roads within campuses |
1024 | Gravel roads for approach to ESRs |
1025 | Construction of HT panel Room Minimum plinth area 24 Sqmtr asper Employer requirement and SpecificationatGandhav,Dheemari, Gudamalani, Bhedana, Adel, Loharwa, Shobhala Jethmal, Dhorimana |
1026 | Construction of Store builindg (Minimum Area 50 Sqm with on side Kota stone shelves 1.0m deep from top to ground level on a long wall) as per Employer requirement and SpecificationatLoharwa, Shobhala Jethmal andDhorimana head works |
1027 | Construction of Local Control Station (LCS) building of minimum 30 sqm area complete in all respect including air conditionersas per Employer requirement and Specificationat Barmer |
1028 | Construction of Village Transfer chamber (VTC)complete in all respect as per the tender drawing, complete in all respect as per Employer requirement and Specification. |
1029 | BILL 8 - SPARE PARTS, TOOLS AND TACKLES |
1030 | Supply of spares for mechanical works for all pumping stations as per scope of work and specifications given. |
1031 | Supply of spares for electrical works for all pumping stations as per scope of work and specifications given. |
1032 | Supply of spares for instrumentation works as per scope of work and specifications given. |
1033 | Supply of spares for pipeline works as per scope of work and specifications given. |
1034 | Supply of tools and tackles as per scope of work and specifications given. |
1035 | Supply of retractable aluminum ladder 4.5m length at all CPSs (19 Nos.) |
1036 | BILL 9 - PRICE SCHEDULE-OPERATION SERVICE(SECTION II) |
1037 | OPERATION SERVICE AFTER DEFECTS NOTIFICATION PERIOD OF ONE YEAR |
1038 | Operation and Maintenance ofPipeline up to VTC, CWRs, ESRs, pump houses, EMI Works,Electro chlorinators at pumping stations etc of the whole works as per Employer requirement and Specification for:- |
1039 | 1st Year |
1040 | 2 rd Year |
1041 | 3 rd Year |
1042 | 4 th Year |
1043 | 5 th Year |
1044 | 6 th Year |
1045 | 7 th Year |
1046 | 8 th Year |
1047 | 9 th Year |
1048 | 10 th Year |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy