Tender For Internal Electrification In 15 Nos C Type Shops, 28 Nos Supermarket And 02 Nos. Warehouse Work, Office Building, Check Post, Construction / Repairing Of Lt Line And High Mast Street Light At Nmy Raibareilly., Rae Bareli-Uttar Pradesh

Rajya Krishi Utpadan Mandi Parishad has published Tender For Internal Electrification In 15 Nos C Type Shops, 28 Nos Supermarket And 02 Nos. Warehouse Work, Office Building, Check Post, Construction / Repairing Of Lt Line And High Mast Street Light At Nmy Raibareilly.. Submission Date for this Tender is 03-04-2024. Electrification Work Tenders in Rae Bareli Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42820508
Tender For Internal Electrification In 15 Nos C Type Shops, 28 Nos Supermarket And 02 Nos. Warehouse Work, Office Building, Check Post, Construction / Repairing Of Lt Line And High Mast Street Light At Nmy Raibareilly.
Open Tender
Indian
Uttar Pradesh
Rae Bareli
03-04-2024

Tender Details

Internal Electrification In 15 Nos C Type Shops, 28 Nos Supermarket And 02 Nos. Warehouse Work, Office Building, Check Post, Construction / Repairing Of Lt Line And High Mast Street Light At Nmy Raibareilly.

Key Value

Document Fees
INR 5100 /-
EMD
INR 285000.0 /-
Tender Value
INR 28.44 Lakhs /-

BOQ Items

Name of Work: Internal Electrification in 15 Nos C Type shops, 28 Nos Supermarket and 02 Nos. Warehouse work, office Building, Check post, Construction / Repairing of LT line and High Mast Street light at NMY Raibareilly.
Sl. No. Item Description
1Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder with modular type switch etc complete in all respects as directed, including matching color wash.
2Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose with modular type switchetc complete in all respects as directed, including matching color wash.
3Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire with modular type switch& socket etc., complete in all respects as directed, including matching color wash.
4Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve6 - 32 amps.Cat. A
5Supply and fixing of 6 Amp to 32 Amp DPMCB(10KA)C Curve6 - 32 amps.Cat. A
6S/F of 8 way SPNDB without MCB
7Supplyand burying safe earthing Electorde T-19(HotDip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25,terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of 12swg withHotDipGavanized up to 100 mirconfilled with crystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable ofreducing the soilresistivitywith good mixture ofretaning capacity along with 30 cm squre C.I. frame with hinged cover & masonryhousing (from electode terminaltoswitchboard , costof 25 x 3 G.I. strip will be extra)Make:As approved in U.P.P.W.D. & C.P.R.I. Certified
8Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.
9Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work.
10Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box including supply of all material, labour T & P etc required for proper completion of work.
11Supply and fixing of water tight oblong 10watt LED bulkhead luminaire with driver set confirming to IP 65 as above protection complete in all respect.
12Supply & wiring of sub mains with two number2 x 4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable concieled in wall & laid in slab 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect.
13Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.501(a) 6 Sqmm X 2 core
14501(h) 10 Sqmm X 4 core
15501(i) 16 Sqmm X 4 core
16501(n) 95 Sqmm X 3.5 core
17Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT AAA
18Erection and testing of ceiling fan and regulator etc. excluding supply of down rod, complete in all respect.
19S/F of Ceiling fan
20Supply and wiring of submain with two number 10 sq.mm. PVC insulated 1100V grade single core copper conductor cable in 25 mm dia heavy guage rigid steel conduit concealed in wall, complete with one number 8 SWG GI earth continuity wire As in item no. 218 (B) but in 25 mm dia heavy duty (2 mm thick) PVC conduit with one No.6 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.
21Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.
22Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia. heavy guage rigid steel conduit on surface, withone number 14 SWG copper earth continuity wire etc, complete in all respect.
23Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduitcomplete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge.
24Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse ntery boxes in case of pedestaal type, cable sockets, ompression glands and indicating lamp on oming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selectorswitches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only Incoming 200 Amp. TPN-1 No Outgoing 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.
25Supply and fixing offactory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 180 Watt. Confirming to IP 66 protection complete in all respect.CAT-AAA
26S/F of potted driver set suitable for 110-130 Watt LED light
27S&F of 100 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.
28S/F of 7.5 HP submersible Pump with control panel, starter & cable etc.
29Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects.
30S/F of 80mm Pipe(Jal Nigam)
31S&F of 63 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect.
32Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect.
33Supply & fixing of 100 mm x 110 mm shackle insulator /100 mm x 80 mm pin insulator including G.I. Bolts / spindle nuts etc. complete in all respect.
34Supply & fixing of 230 mm x 32 mm x 1.5 mm galvanised steel strips including holes for shakcle insulators pins and bolts etc. complete in all respect.
35Supply & erection of "D" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint .
36Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects.
37Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect.
38Supply & erection of hexagonal / cradle type gaused of G.I. wire no. 8 to 4 SWG including binding etc. complete in all respect.
39Supply & erection of stay set at 3.5 Metres away fromthe pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 x 6.3 mm anchor plate, thimble stay clamps, stay insulator,19 mm 600 mm double screw tightener, 7/3.5 mm G.I. stay wire etc. in 1:3:6 cement concrete complete in all respect.
40Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect.
41Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect.
42S/F of G.I. Pipe 50mm
Disclaimer :