}

Tender For Various Repair Work At H.O. Jaipur, jaipur-Rajasthan

Rajasthan State Road Transport Corporation-RSRTC has published Tender For Various Repair Work At H.O. Jaipur. Submission Date for this Tender is 17-03-2024. LED Light Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42818464
Tender For Various Repair Work At H.O. Jaipur
Open Tender
Indian
Rajasthan
jaipur
17-03-2024

Tender Details

Tender For Various Repair Work At H.O. Jaipur- 1 ( Rates Are Based Onintegrated Pwd Bsr Building Work 2022 & Electrical Workspwd Bsr 2022 ) 2 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. 3 Dismantling Doors, Windows And Clearstory Windows Steel Or Wood Shutter Including Chowkhats And Holdfasts Etc. Complete And Stacking Within 50 Meters Lead:Of Area 3 Square Meter And Below. 4 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand ) 5 Removing Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. 6 Repair To Damaged Rcc Slabs, Beams And Columns Etc For Strengthening With Cement Mortar 1 : 2 In Following Steps :-1.Choping Losse And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Papering , Cleaning Of Concrete Surface With Water As Necessary And Getting Dried.2.Applying Epoxy Primer On The Exposed Steel Bars.3.Applying Epoxy Hardener And Resin Mix ( As Per ManufecturedS Specification ) On Concrete And Steel Bars With Brush.4.Speading Dry Cement Mortar 1 : 2 Mix Over Epoxy Treated Wet Surface And Allow It To Dry For One Day.5.Plastering The Surface With Cement Sand Mortar 1 : 3 Upto Depth Of 30Mm Complete.6.Cure The Plastered Surface For 15 Days, All Work Including Scaffolding Etc. Complete In All Respect. 7 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In :Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 8 Plaster On New Surface On Wall In Cement Sand Mortar 1:3 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick 9 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stoneaggregate 20Mm Nominal Size ) . 10 P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes ( Thickness Minimum 10Mm ) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm 11 Add Extra For Fixing Glazed / Ceramic / Vitrified Floor Tiles With Cement Based High Polymer Modified Quick-Set Tile Adhesive ( Water Based ) Conforming To Is: 15477 , Using 5Kg. Adhesive Per Sqm Of Tile Area, In Average 3Mmthickness Instead Of Cement Mortar. 12 Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section ( Is 1038-1983 ) Joints Mitred And Welded With Steel Lugs 13X3mm, 10Cm. Long Embedded In Cement Concrete Block 15X10x10cm. Of 1:3:6 ( 1Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :Partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33% ] 13 Providing And Fixing 15 Mm Thick Densified Tegular Edged Eco Friendly Light Weight Calcium Silicate False Ceiling Tiles Of Approved Texture As Per Direction Of Engineer-In-Charge Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanizing @120 Grams Per Sqm ) Consisting Of Main ‘T’ Runner Suitably Spaced At Joints To Get Required Length And Size Of 24X38mm Made From 0.33 Mm Thick ( Minimum ) Sheet, 1200Mm Centre To Centre, And Cross‘T’ Of Size 24X32mm Made Out Of 0.33Mm ( Minimum ) Sheet, 1200Mm Long Spaced Between Main ‘T’ At 600Mm Centre To Centre To Form A Grid Of 1200X600mm And Secondary Cross ’T’ Of Length 600Mm And Size 24X32mm Made Out Of 0.33 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grid Of Size 600X600mm Resting......On Periphery Walls / Partitions On A Perimeter Wall Angle Pre-Coated Steel Of Size ( 24X24x3000mm Made Of 0.40Mm Thick ( Minimum ) Sheet With The Help Of Rawl Plugs At 450Mm Centre To Centre With 25Mm Long Dry Wall Screws @ 230Mm Interval And Laying 15Mm Thick Densified Edged Calcium Silicate Ceiling Tiles Of Approved Texture In The Grid Including Cutting / Making Opening For Services Like Diffusers, Grills, Light Fitting, Fixtures, Smoke Detectors Etc., Wherever Required, Main ‘T’ Runners To Be Suspended From Ceiling Using 50 Mm Long M 6 Dash Fasteners, 6Mm G.I. Fully Threaded Rods With Galvnised Steel L Cleat Level Adjusters Of Size 80X25x2mm, Spaced At 1200Mm Centre To Centre Long Main ‘T’ Bottom Exposed With 24Mm Of All T-Sections Shall Be Pre-Painted With Polyster Baked Paint, For All Heights, As Per Specifications, Drawing And As Directed By Engineer-In-Charge. Note :- Only Calcium Silicate False Ceiling Area Will Be Measured From Wall To Wall. No Deduction Shall Be Made For Exposed Frames / Opening ( Cut Outs ) Having Area Less Than 0.30 Sqm.The Calcium Silicate Ceiling Tiles Shall Have Nrc. Value 0.50 ( Minimum ) , Light Reflection> 85% Non-Combustible As Per B.S. 476 Part Iv, 100% Humidity Resistance And Also Having Thermal Conductivity <= 0.043 W / M0kc. 14 Providing And Laying App ( Atactic Polypropylene Polymer ) Modified Prefabricated Five Layer 3Mm Thick Water Proofing Membrane, Black Finished Reinforced With Non-Woven Polyester Mattconsisting Of A Coat Of Bitumen Primer For Bitumen Membran @ 0.40 Itr / Sq.Mt. By The Same Membrane Manufacture Of Density At 25°C, 0.87-0.89 Kg / Ltr And Viscosity 70-160 Cps. Over The Primer Coat The Layer Of Membrane Shall Be Laid Using Butane Torch And Sealing All Joints Etc., And Preparing The Surface Complete. The Vital Physical And Chemical Parameters Of The Membrane Shall Be As Under Joint Strength In Longitudinal And Transverse Direction At 23°C As 650 / 450N / 5Cm. Tear Strength In Longitudinal And Transverse Direction As 300 / 250N. Softening Point Of Membrane Not Less Than 150°C. Cold Flexibility Shall Be Upto -2°C When Tested In Accordance With Astm, D-5147. The Laying Of Membrane Shall Be Got Done Through The Authorized Applicator Of The Manufacturer Of Membrane.3 Mm Thick 15 Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compoundconsisting Of Applying : 1.After Surface Preparation, First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound@ 0.253 Kg / Sqm.2.Laying Secondlayer Of Fiber Glass Clothwhen The First Layer Is Still Green. Overlaps Of Joints Of Fiber Cloth Should Not Be Less Than 10 Cm .3.Third Layer Of 1.5 Mm Thickness Consisting Of Slurry Of Cement @ 1.289Kg / Sqm Mixed With Water Proffing Cement Compound@ 0.670Kg / Sqm And Coarse Sand @ 1.289 Kg / Sqm. This Will Be Allowed To Air Cure For4 Hours Followed By Water Curing For 48 Hours. The Entire Treatment Will Be Taken Upto 30Cm On Parapet Wall And Tucked Into Groove In Parapet All Around.4.Fourth And Final Layer Of Brick Tiling ‘With Cement Mortar Or Any Other Approved Protective Coarse. ( Which Will Be Paid For Separately ) For The Purpose Of Measurement The Entire Treated Surface Will Be Measured 16 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats, Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide 17 Extra If Square, Rectangular Hollow Tubelarsections Are Used Or Grill Made By Flats Only 18 Removing Dry Or Oil Bound Distemper By Scrapping Sand Papering And Preparing Surface Smooth Including Necessary Repairs To Scratches By Sandla / Loi And All Scaffolding ( For Colour Changing Only ) 19 Providing And Applying White Cement Based Puttyover Plastered Surface To Prepare The Surface Even And Smooth Complete.Old Plastered Surface ( Two Or More Coats ) 20 Applying One Coat Of Cement Primer Of Approved Brand And Manufacture On Wall Surface Including All Scaffolding: 21 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:Newwork ( Twoormorecoats ) Overandincludingscrappingandprimingcoatwithcement Primer. 22 Old Work ( One Or More Coats ) Including Scrapping Surface Andnecessaryrepairs.Colour Change 23 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg / 10 Sqm ) . 24 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : One Or More Coats On Old Work. 25 Providing And Fixing Of Double Leaf Steel Shutterfor Cupboard, The Frame Is Made Of Pressed Steelisi Section 80X25 Mmx1.25 Mm Thickwith 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Completeincluding Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate Andspray Painting In Approved Shade With Decopaint Of Approved Quality Complete As Per Direction Of Engineer In Charge 26 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Vlevelusing Bricks Of Designation 75 .Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 27 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) For Area Of Each Slab From 2001 To 5000 Sq.Cm 28 P&F Rigid Pvc Pipe ( Is:4985 Mark ) Class Ii / ( 4 Kg. / Cm2. ) Approved Quality / Makeincluding Joining The Pipe With Solvent Cement Rubber Ring And Lubricant.110 Mm Dia 29 P&F Rigid Pvc Pipe Fittings ( Is: 4985 Mark ) Of Approved Quality / Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87 .5.110Mm Dia 30 P&F Rigid Pvc Pipe Fittings ( Is: 4985 Mark ) Of Approved Quality / Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Plain Tee.110Mm Dia 31 P&F Rigid Pvc Pipe Fittings ( Is: 4985 Mark ) Of Approved Quality / Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45.110Mm Dia 32 Providing & Fixing Of Ip20, 2X2 Led Surface / Recessedmounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal / External Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection ( Integral With Light Fixture ) . System Lumen Efficacy Of = 120 Lm / Watt , Thd < 10 % , P.F.=0.95, Cri >80 , Life Time Of Minimum50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofbis Standard Andtrade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing Onhousing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 & Lm80 ) Certificate / Report From Oem Shall Be Submitted.All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr .Recessed Mounting.Minimum Lumen Output 4200 Lm

Key Value

Document Fees
INR 590 /-
EMD
INR 79660.0 /-
Tender Value
INR 39.83 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail