Tender For Supply Installation Testing And Commissioning Of Mgps Work For Trauma Center At Mahuwa Distt. Dausa.

Issued by Government Departments · dausa, Rajasthan
Tender Value
11.02 Lakhs
Estimated cost
Bid Submission
18 Mar 2024
0 days left
EMD
22040
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dausa → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Supply Installation Testing And Commissioning Of Mgps Work For Trauma Center At Mahuwa Distt. Dausa.-2 Sitc Of Mgps Pipe Of Medically Grade As Per Bsen-13348 With Third Party Certification From Lloyds / Tuv Degreased ( Ie Free From Oil, Grease And Particulate Matters ) Seamless Copper Pipe Confirming To Astm B88 And All Copper Joining Done By Brazing With Awsa5.8, Classification Bcup-5 Or Bs 1845 Following Procedure In Accordance With Astm B828 After Purging With Nitrogen. All Pipe Cutting Shall Be Carried Out With A Radial Pipe Cutter And Copper Pipe FittingS Shall Comply With B4 Alloy Designation. Adequate Support Shall Be Provided While Laying Pipeline Testing Shall Be Done At 17 Bar And After Testing Pipe Shall Be Painted With Two Coat Of Enamel Paint As Per Colour Codification As Per Iso 7396-Part-I 2016. Third Party Test Report Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With P.W.D. Electrical Bsr 2021 3 Sitc Of Non Lubricated Ball Type Nickel Coated Isolation Valve With Adapter & Ptfe Seat Having Quarter Turn / Butterfly Handle Opening Of Following Sizes Suitable For Flow Capacity Of Required Lpm As Per The Size Of Valve At 4.7 Bar With Maximum Allowable Pressure Of 30 Bar And Suitable For Working Temperature Ranging - 20°C To 130°C. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021 4 For 12 Mm Od Pipe 5 For 15 Mm Od Pipe 6 For 22 Mm Od Pipe 7 For 28 Mm Od Pipe 8 Sitc Of Gas Outlet Points Oxy, N2o, ( Ar-4 ) , ( Ar-7 ) And Vaccum ( 8.7 Psig ) For Dispensing Medical Gases ( Oxygen / Air / Vaccum ) At Point Of Use Confirming To Bsen Iso 9170-1:2008. The Gas Outlet Are Quick Connect Type , It Should Have Color Coding For Different Gas Source And Should Accept Only Repective Adapters As Required.Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Certified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Echnical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021 9 Sitc Of Bpc ( Back Pressure Compensated ) Flow Meter With Humidifer Made Of Nickel Plated Body, Double Jacketed With Flow Gradations Ce Marked On It. Desired Flow Will Be Setteled Through Rotary Knob. Flow Range Should Be Between 0 To 15 Lpm & Work Should Be Executed As Per Direction Of Engineer In Charge. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Certified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 10 Sitc Of Ward Suction Unit ( Suction Controller And Collectionjar-600 Ml Capacity ) With Posibility To Configure Required Capacity Collection Jar And Should Meets The Requirements As Per Bsen Iso 10079-3:2009. The Unit Must Designed To Operate With The Vaccum Line Of Mgps. The Collection Jar Must Accumpained With Vaccum Regulator Suitable For 0-14.7 Psig With Flow Rate 0-55 Lmp ( Min ) For Operating Temperature- 18°C To 50°C With On / Off Facility. The Collection Jar Should Be Transparent, Made Of High Quality Polycarbonate That Can Be Autoclaved At 121°C For 20 Minutes For Reuse And Provided With Auto Stop To Avoid Over Spill And Contaminatin Of The Suction Source When The Jar Collection Reached Optimized Level. The Complete Unit Supplied With Filter To Protect The Source And Pipe Line From Bacterial Contamination. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 11 Sitc Of Valve Box Made Of Crca Sheet Duly Powder Coated With Transparent Window Which Is Installed In The Mgps For Oxygen And Vaccum Line And Should Comply With Bsen Iso5211:2001 Complete With Ball Type Valves And Gauges As Required For Oxygen Compressed Air And Vaccum Line. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submited. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 12 Three Gas Service 13 Sitc Of Microprocessor Based Auto Alarm ( Digital Type ) Suitable For Medical Gas Service Provided With Audible And Visual Alarm For Mgps Zoning. It Should Monitors The Current Status Of Oxygen / Compresssed Air Pressure In Distribution Pipeline Of Central Medical Supply System And Trigger The Alarm To Alert. The System Should Comply Bsen Iso:7396-I:2007 Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 14 Three Gas Service 15 Sitc Of Bed Head Panel Of 900-1500 Mm Long Made Out From High Strength Extruded Aluminium With Powder Coating With At Least 4 Nos 6 / 16 Amp Switch Socket And Provision For Required Number Of Gas Outlet Points As Suggested By The Client. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 16 Sitc Of Emergency Oxygen / Nitrous Oxide Manifold System ( 2+2 ) With Tail Pipes Nrv And One Dgss Regulator Of Minimum 600 Lpm Capacity- Manifold System Comprise Of Bank Of 2+2 Cylinders ( Bulk Cylinder Of D Type ) Capacity Manifold High Pressure Copper Pipe Of Size 1 / 2Idx14 Swg ( Approx. 2.0320 Mm ) & High Pressure Fitting Made Of High Tensile Strength Brass Be Used To Connect The Cylinders To The Header Assemblies With 4 NoS Non Return Valves & 4 NoS High Pressure Flexible Tail Pipe Is Made Of Copper Pipe Of 1 / 3X16 Swg ( Approx. 1.6256 Mm ) The Manifold Is Hydraulically Tested At 225 Kg / Cm2 Pressure It Is Also Degreased And Is To Be Offered Duly Wrapped In A Polythene Bag Make Ce Approved / Ce Certified. Note: Providing Of Cylinders Is In The Scope Of Hospital / End Client. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021.

BOQ

Name of Work: SITC ofMGPS work for Trauma Center at Mahuwa Distt. Dausa
Sl. No. Item Description
1NON-BSR ITEMS
2SITC of MGPS pipe of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV degreased (ie free from oil, grease and particulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-5 or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipe cutter and copper pipe fitting\"s shall comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 Bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-I 2016. Third party test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with P.W.D. Electrical BSR 2021
3SITC of non lubricated ball type Nickel Coated Isolation Valve with adapter & PTFE Seat having quarter turn/Butterfly handle opening of following sizes suitable for flow capacity of required LPM as per the size of valve at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20°C to 130°C. Appropriate Test certificate/report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021
4For 12 MM OD Pipe
5FOR 15 MM OD Pipe
6FOR 22 MM OD Pipe
7FOR 28 MM OD Pipe
8SITC of Gas outlet points Oxy, N2O, (AR-4), (AR-7) and Vaccum (8.7 psig) for dispensing medical gases (oxygen/air/vaccum) at point of use confirming to BSEN ISO 9170-1:2008. The gas outlet are quick connect type , it should have color coding for different gas source and should accept only repective adapters as required.Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The product should be CE Certified/CE Marked. All as per pre approved by Engineer in charge. For additional echnical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021
9SITC of BPC (back pressure compensated) flow meter with humidifer made of nickel plated body, double jacketed with flow gradations CE Marked on it. Desired flow will be setteled through rotary knob. Flow range should be between 0 to 15 lpm & work should be executed as per direction of engineer in charge. Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The product should be CE Certified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
10SITC of ward suction unit (Suction controller and collectionJar-600 ml capacity) with posibility to configure required capacity collection jar and should meets the requirements as per BSEN ISO 10079-3:2009. The unit must designed to operate with the vaccum line of MGPS. The collection jar must accumpained with Vaccum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for operating temperature- 18°C to 50°C with ON/OFF facility. The collection jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121°C for 20 minutes for reuse and provided with auto stop to avoid over spill and contaminatin of the suction source when the jar collection reached optimized level. The complete unit supplied with filter to protect the source and pipe line from bacterial contamination. Appropriate Test certificate/report of product/accessories from OEM shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
11SITC of valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with BSEN ISO5211:2001 complete with ball type valves and gauges as required for oxygen compressed air and vaccum line. Appropriate Test certificate/report of product/accessories from OEM shall be submited. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
12Three Gas Service
13SITC of microprocessor based auto alarm (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS zoning. It should monitors the current status of oxygen / compresssed air pressure in distribution pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN ISO:7396-I:2007 Appropriate Test certificate/report of product /accessories from OEM Shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
14Three Gas Service
15SITC of Bed Head Panel of 900-1500 MM long made out from high strength extruded aluminium with powder coating with at least 4 Nos 6/16 Amp switch socket and provision for required number of gas outlet points as suggested by the client. Appropriate Test Certificate/Report of product/accessories from OEM shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
16SITC of Emergency Oxygen / Nitrous Oxide Manifold System (2+2) with tail pipes NRV and One DGSS Regulator of Minimum 600 LPM capacity- manifold system comprise of bank of 2+2 cylinders (Bulk cylinder of D type ) capacity manifold high pressure copper pipe of size 1/2\"IDx14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 4 no\"s non return valves & 4 no\"s high pressure flexible tail pipe is made of copper pipe of 1/3\"x16 swg (approx. 1.6256 mm) the manifold is hydraulically tested at 225 Kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag make CE approved /CE certified. Note: Providing of cylinders is in the scope of Hospital/End client. Appropriate Test Certificate/Report of product/accessories from OEM shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.

AI Tender Summary

OUR REF NO 42817642
AUTHORITY Government Departments
TENDER VALUE 11.02 Lakhs
LAST DATE 18-03-2024
Authority
Authority Name Medical And Health Services
Work Description Tender For Supply Installation Testing And Commissioning Of Mgps Work For Trauma Center At Mahuwa Distt. Dausa.-2 Sitc Of Mgps Pipe Of Medically Grade As Per Bsen-13348 With Third Party Certification From Lloyds / Tuv Degreased ( Ie Free From Oil, Grease And Particulate Matters ) Seamless Copper Pipe Confirming To Astm B88 And All Copper Joining Done By Brazing With Awsa5.8, Classification Bcup-5 Or Bs 1845 Following Procedure In Accordance With Astm B828 After Purging With Nitrogen. All Pipe Cutting Shall Be Carried Out With A Radial Pipe Cutter And Copper Pipe FittingS Shall Comply With B4 Alloy Designation. Adequate Support Shall Be Provided While Laying Pipeline Testing Shall Be Done At 17 Bar And After Testing Pipe Shall Be Painted With Two Coat Of Enamel Paint As Per Colour Codification As Per Iso 7396-Part-I 2016. Third Party Test Report Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With P.W.D. Electrical Bsr 2021 3 Sitc Of Non Lubricated Ball Type Nickel Coated Isolation Valve With Adapter & Ptfe Seat Having Quarter Turn / Butterfly Handle Opening Of Following Sizes Suitable For Flow Capacity Of Required Lpm As Per The Size Of Valve At 4.7 Bar With Maximum Allowable Pressure Of 30 Bar And Suitable For Working Temperature Ranging - 20°C To 130°C. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021 4 For 12 Mm Od Pipe 5 For 15 Mm Od Pipe 6 For 22 Mm Od Pipe 7 For 28 Mm Od Pipe 8 Sitc Of Gas Outlet Points Oxy, N2o, ( Ar-4 ) , ( Ar-7 ) And Vaccum ( 8.7 Psig ) For Dispensing Medical Gases ( Oxygen / Air / Vaccum ) At Point Of Use Confirming To Bsen Iso 9170-1:2008. The Gas Outlet Are Quick Connect Type , It Should Have Color Coding For Different Gas Source And Should Accept Only Repective Adapters As Required.Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Certified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Echnical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021 9 Sitc Of Bpc ( Back Pressure Compensated ) Flow Meter With Humidifer Made Of Nickel Plated Body, Double Jacketed With Flow Gradations Ce Marked On It. Desired Flow Will Be Setteled Through Rotary Knob. Flow Range Should Be Between 0 To 15 Lpm & Work Should Be Executed As Per Direction Of Engineer In Charge. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Certified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 10 Sitc Of Ward Suction Unit ( Suction Controller And Collectionjar-600 Ml Capacity ) With Posibility To Configure Required Capacity Collection Jar And Should Meets The Requirements As Per Bsen Iso 10079-3:2009. The Unit Must Designed To Operate With The Vaccum Line Of Mgps. The Collection Jar Must Accumpained With Vaccum Regulator Suitable For 0-14.7 Psig With Flow Rate 0-55 Lmp ( Min ) For Operating Temperature- 18°C To 50°C With On / Off Facility. The Collection Jar Should Be Transparent, Made Of High Quality Polycarbonate That Can Be Autoclaved At 121°C For 20 Minutes For Reuse And Provided With Auto Stop To Avoid Over Spill And Contaminatin Of The Suction Source When The Jar Collection Reached Optimized Level. The Complete Unit Supplied With Filter To Protect The Source And Pipe Line From Bacterial Contamination. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 11 Sitc Of Valve Box Made Of Crca Sheet Duly Powder Coated With Transparent Window Which Is Installed In The Mgps For Oxygen And Vaccum Line And Should Comply With Bsen Iso5211:2001 Complete With Ball Type Valves And Gauges As Required For Oxygen Compressed Air And Vaccum Line. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submited. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 12 Three Gas Service 13 Sitc Of Microprocessor Based Auto Alarm ( Digital Type ) Suitable For Medical Gas Service Provided With Audible And Visual Alarm For Mgps Zoning. It Should Monitors The Current Status Of Oxygen / Compresssed Air Pressure In Distribution Pipeline Of Central Medical Supply System And Trigger The Alarm To Alert. The System Should Comply Bsen Iso:7396-I:2007 Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 14 Three Gas Service 15 Sitc Of Bed Head Panel Of 900-1500 Mm Long Made Out From High Strength Extruded Aluminium With Powder Coating With At Least 4 Nos 6 / 16 Amp Switch Socket And Provision For Required Number Of Gas Outlet Points As Suggested By The Client. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021. 16 Sitc Of Emergency Oxygen / Nitrous Oxide Manifold System ( 2+2 ) With Tail Pipes Nrv And One Dgss Regulator Of Minimum 600 Lpm Capacity- Manifold System Comprise Of Bank Of 2+2 Cylinders ( Bulk Cylinder Of D Type ) Capacity Manifold High Pressure Copper Pipe Of Size 1 / 2Idx14 Swg ( Approx. 2.0320 Mm ) & High Pressure Fitting Made Of High Tensile Strength Brass Be Used To Connect The Cylinders To The Header Assemblies With 4 NoS Non Return Valves & 4 NoS High Pressure Flexible Tail Pipe Is Made Of Copper Pipe Of 1 / 3X16 Swg ( Approx. 1.6256 Mm ) The Manifold Is Hydraulically Tested At 225 Kg / Cm2 Pressure It Is Also Degreased And Is To Be Offered Duly Wrapped In A Polythene Bag Make Ce Approved / Ce Certified. Note: Providing Of Cylinders Is In The Scope Of Hospital / End Client. Appropriate Test Certificate / Report Of Product / Accessories From Oem Shall Be Submitted. The Product Should Be Ce Ertified / Ce Marked. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With Pwd Electrical Bsr 2021.
Basic Detail
Tender No NIT NO. 45/2023-24(05)EEMHALWAR
Bidding Type Tender
Location
City dausa
State Rajasthan
Key Dates
Publish Date 08 Mar 2024
Submission Date 18 Mar 2024
Open Date 19 Mar 2024
Finance
Tender Value 11.02 Lakhs
Tender Fee 500
EMD 22040
Exemption Not Available
Document List
294691c8-18c6-47c8-9fea-aba6ad2b878d.html
BOQ_690595.xls
cond_dlp.pdf
tenderdocs_5.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 08, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 18, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 19, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

294691c8-18c6-47c8-9fea-aba6ad2b878d.html

xls

BOQ_690595.xls

pdf

cond_dlp.pdf

pdf

tenderdocs_5.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender