Repair Maintenance Of Electrical And Mechanical Work Services At Gpo Building Vikas Bhawan-Ii Delhi. ( Sh- Comprehensive Annual Maintenance Of Carrier And Daikin Make Chillers Operation And Day To Day Maintenance Of Ac Plant And Replacement Of Defecti, vikas-Delhi

Public Works Department-PWD has published Repair Maintenance Of Electrical And Mechanical Work Services At Gpo Building Vikas Bhawan-Ii Delhi. ( Sh- Comprehensive Annual Maintenance Of Carrier And Daikin Make Chillers Operation And Day To Day Maintenance Of Ac Plant And Replacement Of Defecti. Submission Date for this Tender is 15-03-2024. Mechanical engineering Service Tenders in vikas Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42809608
Repair Maintenance Of Electrical And Mechanical Work Services At Gpo Building Vikas Bhawan-Ii Delhi. ( Sh- Comprehensive Annual Maintenance Of Carrier And Daikin Make Chillers Operation And Day To Day Maintenance Of Ac Plant And Replacement Of Defecti
Open Tender
Indian
Delhi
vikas
15-03-2024

Tender Details

Repair Maintenance Of Electrical And Mechanical Work Services At Gpo Building Vikas Bhawan-Ii Delhi. ( Sh- Comprehensive Annual Maintenance Of Carrier And Daikin Make Chillers Operation And Day To Day Maintenance Of Ac Plant And Replacement Of Defective Spare Parts )

Key Value

Document Fees
Refer document
EMD
INR 142664.0 /-
Tender Value
INR 71.33 Lakhs /-

BOQ Items

Name of Work: RMO of Electrical & Mechanical work services at GPO Building, Vikas Bhawan-II, Delhi. (SH:- Comprehensive Annual Maintenance of Carrier & Daikin Make Chillers, Operation & day to day Maintenance of AC Plant and Replacement of defective Spare parts).
Sl. No. Item Description
1Sub Work A (Repair Works) Replacement of following defective/unserviceable components in theexisting 400 TR capacity centrifugal type water chiller plant carrier make i/c making connections, testing & commissioning etc complete as required. a) Integrated Starter Module (CEPL130259-07-R)
2Replacement of following defective/unserviceable components in theexisting 1 No 100 TR capacity Screw type water chilling Plant carrier make i/c making connections, testing & commissioning etc complete as required. a) SCPM(PD5-SCPM3)
3Supply and replacement of the 1200mm x 1800 mm size PVCfill sheet for induced draught 500 TR Cooling toweri/c necessary Fill hanger ,tie rods ,bolts &nuts and all other accessories required for fixing ofPVC fills inthe cooling towers i/c dismantling of old/defective PVC Fills from cooling tower and dispose the same at the designated place decided by Engineer-in-charge complete as required.
4Repairing of Cooling Tower body with GRP Repairing kit including all accessories etc complete as required
5SUB WORK B (Operation & day to day maintenance) Running Operation Maintenance of 3Nos. 400 TR & 1 No. 100 TR capacity water cooled chiller Plant installed at Vikas Bhawan-II attending day to day complaints of HVAC Planti.e. condenser pumps, chilled water pumps, Chiller pipe line, condenser pipe line, cooling towers, panel boards and AHUs, FCUs and Air ventilation system i.e. cooling coil, blower, cleaning of filter, electrical panel of AHU, FCU and Air ventilation complete and carrying out the daily drill comprising of cleaning of the HVAC installation, lodging of complaint in the complaint register and providing assistance to the Engineer-inCharge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional on all days of the month including Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc. as required. (Summer Season) 1). Operator cum Wireman - 2 Nos. (6 AM to 2 PM & 2PM to 10 PM). 1 No. in each shift 2). Khallasi - 1 No. (In general Shift). (The Work shall be start w.e.f 05.06.2024 or as per directions of Engineer-in Charge )
6Running Operation Maintenance of 1No. 400 KW hot water generator, installed at Vikas Bhawan-II with all accessories i.e. chilled water pumps, Chiller pipe line, panel boards complete etc. including preventive maintenance, minor repair, regular cleaning & servicing etc. as required and maintaining log book for above installation & periodical checking of installation, as and when required, keeping the entire installation on functional mode by deploying multi-tasking staff on all days of the month including Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc. as required. (Winter Season) 1). Operator cum Wireman - 2 Nos. (6 AM to 2 PM & 2PM to 10 PM). 1 No. in each shift 2). Khallasi - 1 No. (In General Shift).(The Work shall be start as per directions of Engineer-in Charge )
7Sub Work C (Comprehensive Maintenance) Comprehensive Annual Maintenance and routine preventive maintenance of 1 No 400 TR capacity scroll / screw / centrifugal type water chilling machine of Daikinmake alongwith other associated accessories installed at Vikas Bhawan-II, as per terms and condition attached and also as per direction of Engineer-in-Charge. The scope of work consisting of providing tools and tackles, spares parts, equipment, consumables items for smooth and uninterrupted working of the complete System etc as required. (The Work shall be start w.e.f 10.05.2024 or as per directions of Engineer-in Charge )
8Comprehensive Annualmaintenance and routine preventive maintenance of2 Nos 400 TR capacity scroll / screw / centrifugal type water chilling machine model no. 19XR5557354KEH52 - 2 Nos. of Carrier make chiller AC plant alongwith other associated accessories installed at Vikas Bhawan-II, as per terms and condition attached and also as per direction of Engineer-in-Charge. The scope of work consisting of providing tools and tackles, spares parts, equipment, consumables items for smooth and uninterrupted working of the complete System etc as required. ( The work shall bestart after the handing overfrom the Engineer-in-charge or his representative)
9Comprehensive Annual maintenance and routine preventive maintenance of 1 No 100 TR capacity scroll / screw / centrifugaltype water chilling machine model no. 30HXY100A- 1 No. of Carrier make chiller AC plant alongwith other associated accessories installed at Vikas Bhawan-II, as per terms and condition attached and also as per direction of Engineer-in-Charge. The scope of work consisting of providing tools and tackles, spares parts, equipment, consumables items for smooth and uninterrupted working of the complete System etc as required. ( The workshall be start after the handing overfrom Engineer-in-charge or his representative)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail