| 1 | Supply ,Testing, Designing, Erection and commissioning of Control Room for Early Warning SoftwareMonitoring Display (43” LED Full HD Display) Should be reputed brandIntegration with Control Station B/W Siren StationAn Early Warning Mobile app and web based Software controlling system. The software should be suitable for controls upto 100+ sirens, the system can be expand to accommodate changing needs.( Market rate ) |
| 2 | Supply ,Testing, Designing, Erection and commissioning of Local station for Alert, Information and Direct system comprising of the following hardware/software:• Panel/Housing with power supply module• Radio Router/Modem • Dual SIM 3G/4G/5G communication Router• Intelligent Remote Terminal Unit (RTU) or Programmable Logic Controller• Pre-Programmed Audio Amplifier with Omni directional speakers• Starter with feedback arrangement for siren.Strobe Light • Mounting hardware and cable connectors etc.• Set of applications and system softwarePanels for Mounting Hardware:• The panel should be duly wired and sufficiently spaced to accommodate all the equipment.The panel should have IP65 protection and made of SS-304 sheet metal. The earthingbolts should be available at both sides. The enclosure should have double door and a canopy with proper weather protection. The panel should have pad lock arrangement and pole mounting arrangement.The system should be capable to run on both solar operated 24 V DC & 230 V AC Power and Backup: All the stations equipment (i.e. Hooters, PA system, strobe lights, PLCs etc.) must be primarily powered and activated by solar panel. The status of Power Supply must be available in the Control Room.,Siren System:Must have provision of Pre recorded /programmed audio messages in multiple languages. (English/Hindi/ Punjabi.,Strobe Light:Light Color : RedOperating Voltage: 24/12V DC,Flash pattern: Double FlashMounting: Permanent Mount,Flashes per minute -60 FlashesLight output -500 Candela per second.Rated current 0.9 Amperes Strobe Light should be installed in Local Stations in a manner that it is visible from at least 500 m @ ATF=.74.Controller/PLC/RTU:The Controller should be designed to have Communication for wireless mode like GSM, as well as radio-frequency module between control room and All Site Location including Transmitter, Receiver & Repeaters and associated software. Moreover the system shall also be designed to have communication compatibility such as GPRS, Radio, Satellite or Wired mode like Internet, Broadband to transmit data and receive commands remotely. Standards and certifications - (1). Standards CSA C22.2 No 142, UL , (2). EN/IEC 61131.2:2007,(3). Product Certifications shall be from CSA, RCM, IASCE10, CULUS, (4). IEC/EN 611312 Ed 3, completed by IEC61010-2, 201, (5). OCSA-E 1131.2 ,(6). UL 61010.2. 201, (7). Low Voltage: 2006/95/EC, (8). Electromagnetic compatibility: 2023/108/EC,Design Features of PLC:-(1). Full Ethernet architectures with access to data from anywhere: immediate insight into the process., (2). Ethernet transparency allows access to data from everywhere., (3) . Built to withstand extreme temperatures (-10°C to +60°C)., (4). Robust and well-designed controller with a long-life cycle., (5) . Communication Ports 1 no Ethernet port, (MODBUSTCP/IP support).,(6). Inputs / Outputs Controller should have built-in ON board minimum IOs 8 digital inputs, 8 digital outputs and 2 Analog Inputs (0 to 10volt) Inbuilt RTC support., (7) . Memory Controller shall have minimum 2MB internal RAM memory, 2MB programs constants., (8) . Controller shall be battery less system type., ( 9) . Extensive and simple to use management tool for firmware and program management in large scale PLC applications., (10). Simple: compact size, all in one, which reduces Installation time. ,( 11). Reliable and extremely accurate to accommodate sun positioning algorithms., (12). Basic Software package should also be from the same source as that of PLC/RTU, (13). The software should be Mobile app and web based controlling system, the system can be expand to accommodate changing needs., (14). Total 50,000 Nos Text Message Service for Alert Systems for local resident., (15). All the equipment’s software and hardware should cover minimum 03 years of onsite warranty. Manufacturer. Preferred Makes for PLC System/RTU: Siemens/ ABB/Cyber security on:- (1). Access to the controller shall be password protected. Additionally, only selected devices are allowed to connect to controller., (2) . Memory protection mode is available via physical inputs or software configuration. The application and user data are protected in this mode, (3). Run/Stop protection mode is available via physical . Programming Software for RTU:- The control logic shall be programmed using intuitive flow chart programming. The Programming software shall have following features- (1). Logic building (2). Debugging tools such as break nodes, break points, watch nodes etc. (3). It shall be possible to define watch variables and modify them.(4). Should support built in simulator for off line testing of logic.(5). It shall be possible to see the effect of logic execution using mimic generated.(6). Logic shall be divided into emergency, sequence and interlocks.(7). It shall have a library of timers, counters and PID function blocks. ( Market Rate ) |
| 3 | Supply, Testing, Designing, Erection and commissioning of Autonomy of the SystemThe system should have Solar Panels of Sufficient Rating to be autonomous for minimum three days i.e. the system should have sufficient storage capacity in the shape of batteries charge controller and other accessories required for successful operation of the system in case of non- availability of sunlight and the system operate for minimum five times in a day. Solar panel with 24/12V DC output with required W/VA capacity to be decided by the vendor. The System should be capable of bearing the load of the Local Control System for 3 sunless days in a row. Batteries are to be mounted in the same pole/placed on foundations in a cabinet having IP 65 suitable for open environment.Each Siren should have 24/12V batteries inside controller, to ensure dissemination of warning messages in case of failure of AC mains power.Battery Backup should be sufficient days of idle running + minimum operations (5 messages of 6 duration each).The Solar Panel shall conform to IEC 61215(Latest edition certificate) and IEC 61730. 2023.Approved Make: Vikram / Waaree / REIL /TATA Solar Reputed Make. ( Market Rate ) |
| 4 | Supply, Testing, Designing, Erection and commissioning of Electronic Siren up to 2 kmThe Sirens should be Omni directional and the system audio output must be of high quality and distinctly audible upto 2 Km from Siren/Hooter point for Considering ambient noise, system audio output must be at least 3dB above the ambient noise conditions.High Power Electronic Siren System each with a minimum acoustic power of 120 db (1.4 km meter for Siren & 1.2 km for PA System).The 24/12 V batteries inside the siren controller must be charged by regular 220V AC mains and should have the option for connecting to Solar Panel without the need of an external UPS or inverter.Siren Controller box must be IP65 compliant (or better).• Operating Temperature: -10 to +60deg CThe system must have a capability to run continuously for 15minutes without overheating/failure.The system must adhere to EN 60065 certification for compliance to highest EuropeanSafety Standards and ISO 9001:2008 certification of product design and manufacturing. Equivalent International i.e., UL, FEMA and Indian Certifications are also acceptable.Standby mode current should not exceed 60mA.Dual feature of Control Remotely from Control Room and Locally at the Siren Controller box for authorized user.Siren Speaker Array must be at ground potential. Lighting arrestors must be provided.There must be provision expanding/increasing the horns in future.( Market Rate ) |
| 5 | Supply, Testing, Designing, Erection and commissioning of Earthing of local stationFor the safety of all the installed Electrical and Electronic equipment, 02 meter 2 nos. at each location earthing must be done by the agency. Earthing is to be provided as per IS 3043:1996, ISI StandardSpecification No: 732-1963 or latest edition. ( Market Rate ) |
| 6 | Supply ,Testing, Designing, Erection and commissioning of Feedback Unit for status of Local Stations at Control RoomAll feedbacks (On, Off, Trip, Faults etc) of the equipment installed for Alert, Information and Direct system should communicate to main Control room SCADA.( Market Rate ) |
| 7 | Supply, Testing, Designing, Erection and commissioning of Interface system for Radio and 3G/4G/5G link on wireless communication through dual SIM and associated software at control room ,A suitable interface/communication system of reputed make should be installed in the Local Station with the capability of operating over 3G/4G/5G Link through Dual SIM and should be accordingly interfaced with main Control Room SCADA. ( Market Rate ) |
| 8 | Supply, Testing, Designing, Erection and commissioning of Mounting Poles for Local StationsPole for Mounting of the system:Minimum height of pole required is 10 meters, Gl pole /S355 grade as per BSEN10025 having maintenance access and suitable platform with a safe and reliable raising and lowering mechanism for accessories mounted on the pole is to be applied along with the system for floor /ground mounting. The clamps, nuts and bolts etc. are also to be provided.Pole Foundation: The foundation /concrete base for mounting of pole will be in vendor\"s scope and the bidder shall provide foundation /Structural details of the siren mount along with the pole/tower for the siren system to withstand wind speed of 150 Km/hr.Soil testing to be carried out and further foundation to be designed based on the load bearing capacity of soil.MS fencing: The fencing should have a height of 6 feet. Dimension 4ft x 4ft (or higher depending on the pole or tower structure offered) along with the associated equipment and barbed razor wire at the top. Double coat Paint to de done of color specified by the EIC. Lockable gate of dimension 6ft height and 3ft width. ( Market Rate ) |
| 9 | Supply, Testing, Designing, Erection and commissioning of Emergency Push Buttons at Local StationsThere should be provision of Operating the system from Local via Push buttons in case of Emergency. ( Market Rate ) |
| 10 | Supply, Testing, Designing, Erection and commissioning of Cable and required mounting accessoriesPower Cables and Accessories: All required power cables and accessories to make the system functional will be supplied by the vendor.Cables should comply with IS-694, IS-3961, IS8130 and IS-5831. MAKE: Polycab / Finolex / Universal / Havells( Market Rate ) |
| 11 | Supply ,Testing, Designing, Erection and commissioning of Mandatory Spares (one set)I) One No. SirenII) RTU / PLC-1set?) Solar Charge ControllerIV) ModemV) Strobe Light( Market Rate ) |
| 12 | Supply, Testing, Designing, Erection and commissioning of Dual SIM 3G/4G/5G VPN RouterSupport TCP server,Design with standard TCP/IP protocol stackSupport APN/VPDNOSupport Dual SIM/UIM cardSupport VPN clientCellular SpecificationGSM/GPRS/EDGE• CDMADTX Power<32 dbmRX sensitivity - 93.30 dbmHardware SystemCPU Industrial 32bits CPUFLASH 16MB (Extendable to 64MB)DDR2 128MB (Extendable to 256MB)Interface type, Ethernet-1 No.( Market Rate ) |