Tender For Supply Of Lab Equipments Along With Cost For District Level Laboratory And Sub-Divisional Level Laboratories (District Kargil. (Under Jjm)., kargil-Jammu And Kashmir

Public Works Department-PWD has published Tender For Supply Of Lab Equipments Along With Cost For District Level Laboratory And Sub-Divisional Level Laboratories (District Kargil. (Under Jjm).. Submission Date for this Tender is 18-03-2024. Laboratory Equipment Tenders in kargil Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42807142
Corrigendum : Tender For Supply Of Lab Equipments Along With Cost For District Level Laboratory And Sub-Divisional Level Laboratories (District Kargil. (Under Jjm).
Open Tender
Indian
Jammu And Kashmir
kargil
18-03-2024

Tender Details

Supply Of Lab Equipments Along With Cost For District Level Laboratory And Sub-Divisional Level Laboratories (District Kargil. (Under Jjm). , Membrane Filtration Assembly (Mft) For Micro-Biological Analysis (Manifold Three Place/Funnels), Each Part Separatable, Autoclavable Complete.Electrically Operated Vacuum Pump Max Pressure Delivered 700Mbar, Noise Level Low As 60 Decibel Iso 8199, Suction Flask, Filtration Head 02 And Silicon Tubing, 100 Ml 150 No Funnels (Re-Usable And Autoclavable) And 150 No 0.45 Um 47Mm Gridded Filter. With Stainless Steel Forceps (Sets) , Bacteriological Incubator, Ss304, Insulated Door And Fitted With Heavy Hinges And Should Have Double Glass Window 5?C Above Ambient To 60 ?C, Accuracy +-0.5 ?C Degree Centigrade, Led Display, With Capacity Of 100-200Litre, Micro-Processor Based Pid Controller, With Removable Shelves, 220V 50 Hz, Safety Alarm, Auto Power Breakoff Etc , Double Distillation Unit All Quartz Double Distillation Unit With Demountable Boiler, Vertical Type, Automatic Output:1.5 Litres/Hr Cooling Water Requirements:1 Litres/Min Distillation Temperature: 65-75°C Distillate Quality: Pyrogen Free Voltage: 230-250V,50/60Hz. Conductivity (S/Cm) =<1X10-6, Power: 3 Kw Heater.Heater: Quartz, Boiler: Quartz Condenser: Quartz With Auto Power Cut-Off , Refrigerator: Single Door (Glass) Upright General-Purpose Laboratory Refrigerator, With Temperature Range 0 To 8 Degree Celsius, Capacity Above 340-360 Liters, For Storage Of Culture Media & Sample , Uv Laminar Air Flow Cabinet For Sterilization. Iso 9001 And 13485 Vertical Free Standing Bench Top, Working Table Size: 3X2x2 Feet, Made Of Stainless-Steel Sheet (Ss-304 Grade). Exterior Surfaces Epoxy Painted, Side Panels & Front Doors 6 Mm Thick Acrylic Transparent Plexi Glass. Ulpa Filter, With Pre-Filter Fitted Filter Efficiency 99.99%, 0.12 Micron And Larger, Fluorescent Lighting 20W, Uv Germicidal Lamp, Ac 220V, 50 Hz, Static Pressure Manometer, Air Velocity 4-4.5M/S, Noise Level Less Than 65 Db, With Uv Hour Meter, Led Display For Velocity, Time And Lamp On /Off, Cock For Gas And Air Make , Hot Plate With Magnetic Stirrer Pmdc Motor For Higher Torque Even At Low Speeds, Better Speed Regulation Even With Small Volume And Low Speeds, Accurate Stepless Speed Control Maintains Excellent Speed Stability. Digital Speed Indicator For Displaying Of Stirring Speed, Totally Enclosed Unit, Designed For Use Even In Corrosive Atmosphere Technical Specs 1. Stirring Capacity: 2 Ltr 2. Healing Capacity: 300 Watts 3. Stirring Paddle (Ptfe Coated): 13 Dia X 50 Mm , Uv/Vis Spectrophotometer. Split Beam/Double Beam, Xenon Flash Light Source/ Deuterium Lamp, Tungsten Halogen Lamp, Min 190Nm And Max 1100 Nm Wavelength, Automatic Stray Light And Baseline Correction. Measurement, Method, Transmittance, Absorbance, Concentration (Wavelength, Time), 230 V ± 10, 50 Hz , Benchtop Conductivity/Tds Meter With Inbuilt Atc Probe: User-Friendly Design For Training And Routine Measurements. Meter Having Option To Measure Conductivity/Tds/Temp/Salinity. Usb Interface Data Logger (Up To 1000 Data Sets: Date, Time) Lcd Display, Details Technical Specification: Measuring Range: Cond.: 0.2 ?S/Cm - 200 Ms/Cm, Tds: 0.1 Mg/L…100G/L, Salinity: 0,01…100 Pp, Temperature: -10 ... 100 °C Resolution: Automatic Scale Accuracy: ±1 Digit, ± 0.5 % Of The Measuring Range, T [°C] ± 0.5 °C) Temperature Compensation: Automatic Or Manual Connectors: Bnc/ Banana Connector Calibration: Three-Point, Automatic Nist Approved Stds Data Storage : 1000 Data Sets: Date, Time Interface: Usb Display: Graphic Or Digital, Backlit Liquid Crystal Interface: Usb Housing Protection: Ip40 Or Better Measuring Parameters Cond/Tds/Salinity/Temp., Including Stand, Power Supply, Cond. Cell And Cond. Standards Nist Traceable , Portable Turbidity Meter The Instruments Are Portable, Battery-Operated Turbidity Meters. The Easy Operation, The Practical Carrying Case That Ensures That The Electronic Components Are Adequately Protected Make The Ideal Instruments For On-The-Spot Analysis. Scope Of Delivery:Sample Cells, Manual, Carrying Case, 4 Batteries Measuring Principle: Nephelometric 90° Scattered Light Light Source: Tungsten Lamp Indication Of Units: Ntu / Fnu Measuring Range: Min 0–1000 Ntu Resolution: 0.01 Ntu Accuracy: ±2 % Of The Measured Value Calibration: Automatic 3 Points Compliance: Usepa 180.1 Display: Lcd Power Requirement: 110-230 Vac, 50/60 Hz Protection Type: Ip 67 Power Requirements: 4 Batteries, Aaa , Analytical Weighing Box. 1 Mg To 200 Gm (Class F1), Material Of Weight Brass, Pre Calibrated, Material Of Pack Wooden Box, Finished Surface, Iso Certified, With Calibration Certificate From Nabl Accredited Calibration Laboratory. , Digital Thermo-Hygrometer With Sensor Probe Specification: Temperature Range -50 Degree C To +70 Degree C, Temperature Accuracy + 1.0 Degree C, Humidity Measurement Range: 10% Rh To 99% Rh, Humidity Accuracy + 5%, Humidity Resolution 1%, Temp Resolution 0.1 Degree C , Safety Shower Unit Description: Separate Safety Shower And Eyewash Or Combined Modular Unit.Design Temperature And Pressure: Considering The Ambient Effect Of The Region. Service Fluid: Normally Potable Water Compatible Piping Specification: Normally Ss Pipe Design Standard: Isea / Ansi Z358.1End Connections: Mostly Flanged Connected Pipe Size: Normally 2-Inch Drain Outlet Connection: Normally 2 Inch , Hot Air Oven Double Walled Chamber Size 18”X18”X18” With Inner Chamber Made Ss 304 Outer Chamber Of G.I Powder Coated With 65Mm Insulation Of Glass Wool. Temperature 5 Degree C Above Ambient To300 °C With 3 Side Heaters. Temperature Controlled Pid Controller, Temperature Accuracy Of 1.0 Degree C,Supplied With 2 No’S Of Ss Shelves And With Air Circulating Fan For Uniformtemperature. Door Closer With Locking Arrangement , 2. Mono Pan Analytical Digital Balance, 3.0.1Mg To 220Gm With Auto Calibration Facility. Capacity: 220 Gm. Readability: -Min.: 0.0001 Gm (0.1Mg), Max: 220 Gm Or Better Repeatability: -+/- 0.0001Gm Linearity: - +/- 0.0002Gm Pan Size: - 90 Mm ? (Stainless Steel 316 Grade) Round Edge Calibration: -Fully Automatic, External Adjustment With Cal Done Indication Display: -High Contrast Enlarged Advanced Eye Protected Backlit Lcd Display Key Feature: -Auto Self Checking Function, Anti Vibration Feature And Auto Filtration For Matching Environment Conditions Technology: -Based On Electromagnetic Force Compensation (Emfc) Advanced Microcontroller Overload Protection: - Yes ,150% Of Full Scale (Up To 350G) Interface: Rs232, Usb, 1500V, Extra Protection: Protection Of Main Balance Configuration, Airtight Rust & Dust 6 Proof Weighing Chamber (Ip54) Tare Range: 100% Full Response Time: 3 Sec. Draft Shield: Yes, With 3 Opening Door – Left, Right And Top Smooth Glass Slider Operating Temp: + 5°C To + 40°C Weighing Units: Gm, Mg, Ct, Kg, Tola, Lb, Gn, Oz, Ozt, Dwt, Etc (20 Standard Global Weighing Unit) Power Requirement:-Input- Ac110~230V, 50/60 Hz, +/- 15% Output – Dc 7~8V Sensitivity Drift: +/- 1Ppm/°C Housing: Inside High Grade Chemical Resistant Metal And Outside High Grade Anti Static Abs Approved:Iso, Ce, Nabl, Legal Metrology (Gov. Of India) Standard Accessories: Ac-Dc Adapter, Ss Calibration Weight, Ss Pan, Ss Dust Cover Ring, Operating Manual, Below Weighing Hook, Draft Shield. , Autoclave Vertical Double Walled, 450Mm Diax 600Mm Height, 98 Litre Exterior Wall And Lid Ss304 (Mirror Finish), Sealing : Neoprene Rubber Interior Wall Ss304, With Silicon Gasket Working Pressure: 15-20 Psi, But Tested Up-To 40 Psi (Asme) Accuracy +3Psi Working Temperature: 121-125 Degree C Auto Set Controller To: 15 Psi &121 Degree C Pressure Gauge Display, With Timer And Stainless-Steel Basket 220 V, 50 Hz, 4Kw, Heating : Isi Marked Immersion Heater. With Low Water Level Indicator, Automatic Pressure Switch, Steam Release Vales, Water Outlet Vales, Safety Valves, Power Cable, End Cycle Buzzer. , Benchtop Dual Ph And Ion Meter With Ph Probe And Fluoride Electrode 5-Point Ph Calibration, Up To 5-Point Ise Calibration With Optional Non-Linear Auto Blank And Low Concentration Stability. Should Be Able To Fix Calibration Error Without A Complete Recalibration With Calibration Editing. Automatic Recognition Of Usa/Nist And Din Buffers Meter Controlled Stirrer Probe To Stir The Samples With Ease Recall Calibration Slope Data For Procedure Checks Non-Volatile Memory Should Hold Up To 2000 Data Points With Time And Date Stamp. Should Be Able To Store Up To 10 Methods For Customized Procedures To Differentiate Between Tests And/Or Users. Transfer Data With Usb, Rs232 Ports. Should Have Convenient, Built-In Quick-Start Guide Waterproof And Protected Within Ip54 Rated Housing Specifications : Ph Details Technical Specification: Measuring Range: Ph: -2 . 16; - 1,999 .. 1,999 Mv; Temperature: -10 ... 100 °C, Resolution: 0.01 Ph; 1 Mv; 0.1 °C, Accuracy:Ph: ± 0.02 T [°C] ± 0.1 (0..100 °C) Temperature Compensation: Automatic Bnc, Banana Connector, Calibration Three-Point, Automatic, Nist Approved Stds Data Storage: Up To 1000 Data Sets: Date, Time Display: Graphic Or Digital, Backlit Liquid Crystal Interface: Usb, Housing Protection: Ip40 Or Better Mv/Rmv Mv Range – Mv : ±2000.0 Mv Resolution : 0.1 Relative Accuracy : ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater ,Relative Mv Calibration : Yes Eh Orp Mode : Yes, Ise Range : 0.0001 To 19900 Resolution : 0.0001 Minimum, Auto Ranging, Up To 3 Significant Digits, Relative Accuracy : ±0.2Mv Or ±0.05% Units : Ppm, M, Mg/L, %, Ppb, None Calibration Points : Up To 5, Calibration Editing : Yes Calibration Features : Linear Point To Point, Non Linear Selectable Auto Blank, Low Concentration Range Stability Temperature Range : -5 To 105 °C, 23 To 221 ºf, Resolution: 0.1 Relative Accuracy : ±0.1 Temperature Compensation : Automatic Or Manual Temperature Offset Calibration : 1 Point Datalogging Number Of Points: 2000 With Time And Date Stamp Log Function: Manual, Automatic With Auto-Read™ , Timed Log Edit : Delete Last Reading Or All Inputs Ph Electrode / Ise: Bnc, Reference Pin, Atc Probe: 8-Pin Mini-Din Outputs Rs232, Usb Power Ac Adapter : Included – Universal, 100-240 Vac Battery Power: Optional – 4 Aas Battery Life 800 Hrs Following Electrodes Should Be Supplied:Fluoride Ion Selective Electrode, Range: 1 X 10-6 M To Saturated, 0.02 Ppm To Saturated, 100Ppm Fluoride Standard, Ionic Strength Adjuster & 1000Ppm Calibration Standard Solution. , Water Bath: Nominal Capacity, 12 Liter Temperature Range 5 To 99 Degree C, Temperature Accuracy +- 0.2 Degree C Ac 230-240V, 50Hz Epoxy/Powder Coated Stainless Steel Outer Chamber, Ss304, With 6 Number Hole/Concentric Ring. Power Requirement, 900W, Pid Based Digital Temperature Controller, Over Temp Alarm And Cut Off, With Seamless Stainless-Steel Pan, Inbuilt Water Level Sensor, And Non-Corrosive Ring.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Mar-2024 Corrigendum Date 18-03-2024

Key Value

Document Fees
INR 838 /-
EMD
INR 167500.0 /-
Tender Value
INR 83.75 Lakhs /-

BOQ Items

Name of Work: Supply of Lab equipments along with cost for district level laboratory and sub-divisional level laboratories (district Kargil. (Under JJM).
Sl. No. Item Description
1Membrane filtration Assembly (MFT) for micro-biological analysis (manifold three place/funnels), each part separatable, autoclavable complete.electrically operated vacuum pump max pressure delivered 700mBar, noise level low as 60 decibel ISO 8199, suction flask, filtration head 02 and silicon tubing, 100 ml 150 No funnels (re-usable and Autoclavable) and 150 No 0.45 um 47mm gridded filter. With stainless steel forceps (sets)
2Bacteriological incubator, SS304, Insulated door and fitted with heavy hinges and should have double glass window 5?C above ambient to 60 ?C, accuracy +-0.5 ?C degree centigrade, Led display, with capacity of 100-200litre, Micro-processor based PID controller, with removable shelves, 220v 50 hz, safety alarm, auto power breakoff etc
3Double Distillation unit All Quartz Double Distillation Unit With demountable boiler, Vertical Type, Automatic Output:1.5 litres/hr Cooling Water Requirements:1 litres/min Distillation Temperature: 65-75°C Distillate quality: Pyrogen free Voltage: 230-250v,50/60Hz. Conductivity (s/cm) =<1x10-6, Power: 3 KW Heater.Heater: Quartz, Boiler: Quartz Condenser: Quartz With auto power cut-off
4Refrigerator: Single door (glass) upright general-purpose laboratory refrigerator, with temperature range 0 to 8 degree Celsius, capacity above 340-360 liters, For storage of culture media & sample
5UV laminar air flow Cabinet for Sterilization. ISO 9001 and 13485 VERTICAL free standing bench top, working table Size: 3x2x2 feet, made of Stainless-Steel Sheet (SS-304 grade). Exterior surfaces epoxy painted, Side panels & front doors 6 mm thick acrylic transparent plexi glass. ULPA filter, with pre-filter fitted Filter efficiency 99.99%, 0.12 micron and larger, fluorescent lighting 20w, UV germicidal lamp, AC 220v, 50 HZ, static pressure manometer, air velocity 4-4.5m/s, noise level less than 65 db, with UV Hour meter, LED display for velocity, Time and lamp on /off, cock for gas and air Make
6Hot Plate with Magnetic Stirrer PMDC motor for higher torque even at low speeds, Better speed regulation even with small volume and low speeds, Accurate stepless speed control maintains excellent speed stability. Digital Speed Indicator for displaying of stirring speed, Totally enclosed unit, Designed for use even in corrosive atmosphere Technical Specs 1. Stirring Capacity: 2 Ltr 2. Healing Capacity: 300 Watts 3. Stirring Paddle (PTFE Coated): 13 dia x 50 mm
7UV/VIS Spectrophotometer. Split beam/double beam, xenon flash light source/ Deuterium Lamp, Tungsten Halogen Lamp, min 190nm and max 1100 nm wavelength, automatic stray light and baseline correction. Measurement, method, Transmittance, Absorbance, Concentration (Wavelength, time), 230 V ± 10, 50 Hz
8Benchtop Conductivity/TDS Meter with Inbuilt ATC Probe: User-friendly design for training and routine measurements. Meter having option to Measure Conductivity/TDS/Temp/Salinity. USB interface Data logger (up to 1000 Data sets: Date, Time) LCD Display, Details Technical Specification: Measuring range: Cond.: 0.2 µS/cm - 200 mS/cm, TDS: 0.1 mg/l…100g/l, Salinity: 0,01…100 pp, Temperature: -10 ... 100 °C Resolution: Automatic scale Accuracy: ±1 digit, ± 0.5 % of the measuring range, T [°C] ± 0.5 °C) Temperature compensation: Automatic or manual Connectors: BNC/ Banana connector Calibration: Three-Point, Automatic NIST approved stds Data storage : 1000 Data sets: Date, Time Interface: USB Display: Graphic or Digital, backlit liquid crystal Interface: USB Housing protection: IP40 or better Measuring parameters Cond/TDS/Salinity/temp., Including stand, power supply, Cond. Cell and cond. Standards NIST Traceable
9Portable Turbidity Meter The instruments are portable, battery-operated turbidity meters. The easy operation, the practical carrying case that ensures that the electronic components are adequately protected make the ideal instruments for on-the-spot analysis. Scope of delivery:Sample cells, manual, carrying case, 4 batteries Measuring principle: Nephelometric 90° scattered light Light source: Tungsten lamp Indication of units: NTU / FNU Measuring range: Min 0–1000 NTU Resolution: 0.01 NTU Accuracy: ±2 % of the measured value Calibration: automatic 3 points Compliance: USEPA 180.1 Display: LCD Power requirement: 110-230 Vac, 50/60 Hz Protection type: IP 67 Power requirements: 4 batteries, AAA
10Analytical Weighing box. 1 mg to 200 gm (Class F1), material of weight brass, pre calibrated, material of pack wooden box, finished surface, ISO certified, with calibration certificate from NABL accredited Calibration laboratory.
11Digital Thermo-Hygrometer with Sensor Probe Specification: Temperature range -50 degree C to +70 degree C, Temperature accuracy + 1.0 Degree C, Humidity measurement range: 10% RH to 99% RH, Humidity Accuracy + 5%, Humidity Resolution 1%, Temp Resolution 0.1 Degree C
12Safety Shower Unit Description: Separate safety shower and eyewash or combined modular unit.Design temperature and Pressure: Considering the ambient effect of the region. Service Fluid: Normally Potable Water Compatible Piping Specification: Normally SS pipe Design Standard: ISEA / ANSI Z358.1End connections: Mostly flanged Connected pipe size: Normally 2-inch Drain Outlet connection: Normally 2 incH
13Hot Air Oven Double walled chamber size 18”x18”x18” With inner chamber made SS 304 outer chamber of G.I powder coated with 65mm insulation of glass wool. Temperature 5 degree C above ambient to300 °C with 3 side heaters. Temperature controlled PID controller, temperature accuracy of 1.0 degree C,supplied with 2 no’s of SS shelves and with air circulating fan for uniformtemperature. Door Closer with locking arrangement
142. Mono pan Analytical Digital Balance, 3.0.1mg to 220gm with Auto Calibration facility. Capacity: 220 gm. Readability: -Min.: 0.0001 gm (0.1mg), Max: 220 gm or better Repeatability: -+/- 0.0001gm Linearity: - +/- 0.0002gm Pan size: - 90 mm ? (Stainless Steel 316 grade) round edge Calibration: -Fully automatic, External adjustment with CAL DONE indication Display: -High Contrast Enlarged Advanced Eye Protected Backlit LCD Display Key Feature: -Auto Self checking function, anti vibration feature and auto filtration for matching environment conditions Technology: -Based on Electromagnetic Force Compensation (EMFC) advanced Microcontroller Overload Protection: - Yes ,150% of full scale (up to 350g) Interface: RS232, USB, 1500V, Extra Protection: Protection of Main Balance Configuration, Airtight Rust & Dust 6 proof weighing chamber (IP54) Tare range: 100% Full Response time: 3 sec. Draft shield: Yes, with 3 opening door – left, right and top smooth glass slider Operating temp: + 5°C to + 40°C Weighing Units: gm, mg, ct, kg, tola, lb, gn, oz, ozt, dwt, etc (20 standard global weighing unit) Power Requirement:-Input- AC110~230V, 50/60 Hz, +/- 15% Output – DC 7~8V Sensitivity drift: +/- 1ppm/°C Housing: Inside high grade chemical resistant metal and outside high grade anti static abs Approved:ISO, CE, NABL, Legal Metrology (Gov. of India) Standard Accessories: AC-DC Adapter, SS Calibration weight, SS pan, SS dust cover ring, Operating Manual, below weighing hook, Draft shield.
15Autoclave Vertical Double walled, 450mm diaX 600mm height, 98 litre Exterior wall and Lid SS304 (mirror finish), Sealing : neoprene rubber Interior wall SS304, with Silicon gasket Working pressure: 15-20 psi, but tested up-to 40 psi (ASME) Accuracy +3psi Working temperature: 121-125 Degree C Auto set Controller to: 15 psi &121 Degree C Pressure Gauge display, with timer and stainless-steel basket 220 v, 50 Hz, 4KW, Heating : ISI Marked Immersion Heater. With Low water level indicator, Automatic pressure switch, steam release Vales, water outlet vales, safety valves, power cable, end cycle buzzer.
16Benchtop Dual pH and ION Meter with pH probe and Fluoride Electrode 5-point pH calibration, up to 5-point ISE calibration with optional non-linear auto blank and low concentration stability. Should be able to fix calibration error without a complete recalibration with calibration editing. Automatic recognition of USA/NIST and DIN buffers meter controlled Stirrer probe to stir the samples with ease recall calibration slope data for procedure checks Non-volatile memory should hold up to 2000 data points with time and date stamp. Should be able to store up to 10 methods for customized procedures to differentiate between tests and/or users. transfer data with USB, RS232 ports. Should have Convenient, built-in Quick-Start Guide Waterproof and protected within IP54 rated housing Specifications : PH Details Technical Specification: Measuring range: pH: -2 . 16; - 1,999 .. 1,999 mV; Temperature: -10 ... 100 °C, Resolution: 0.01 pH; 1 mV; 0.1 °C, Accuracy:pH: ± 0.02 T [°C] ± 0.1 (0..100 °C) Temperature Compensation: Automatic BNC, banana connector, Calibration Three-point, Automatic, NIST approved stds Data storage: up to 1000 Data sets: Date, Time Display: Graphic or Digital, backlit liquid crystal Interface: USB, Housing protection: IP40 or better mV/Rmv mV Range – mV : ±2000.0 mV Resolution : 0.1 Relative Accuracy : ±0.2 mV or ±0.05 % of reading whichever is greater ,Relative mV Calibration : Yes EH ORP mode : Yes, ISE Range : 0.0001 to 19900 Resolution : 0.0001 minimum, auto ranging, up to 3 significant digits, Relative Accuracy : ±0.2mV or ±0.05% Units : ppm, M, mg/L, %, ppb, none Calibration Points : up to 5, Calibration editing : Yes Calibration features : Linear point to point, non linear selectable auto blank, low concentration range stability Temperature Range : -5 to 105 °C, 23 to 221 ºF, Resolution: 0.1 Relative Accuracy : ±0.1 Temperature Compensation : Automatic or manual Temperature Offset Calibration : 1 point Datalogging Number of Points: 2000 with time and date stamp Log Function: Manual, Automatic with AUTO-READ™ , timed Log Edit : Delete last reading or all Inputs pH Electrode / ISE: BNC, reference pin, ATC Probe: 8-pin mini-DIN Outputs RS232, USB Power AC Adapter : Included – universal, 100-240 VAC Battery Power: Optional – 4 AAs Battery Life 800 hrs Following electrodes should be supplied:Fluoride Ion selective Electrode, range: 1 x 10-6 M to saturated, 0.02 ppm to saturated, 100ppm Fluoride standard, Ionic strength adjuster & 1000ppm Calibration Standard Solution.
17Water Bath: Nominal Capacity, 12 Liter Temperature range 5 to 99 degree C, Temperature accuracy +- 0.2 degree C AC 230-240V, 50Hz Epoxy/powder coated stainless steel outer chamber, SS304, with 6 number hole/concentric ring. Power requirement, 900W, PID based digital temperature controller, Over temp alarm and cut off, With seamless stainless-steel pan, inbuilt water level sensor, and non-corrosive ring.
Disclaimer :