Tender For Additional/Alternator To Bldg No P-899 At Chandimandirmil Stn, chandimandir-Haryana

Military Engineer Services-MES has published Tender For Additional/Alternator To Bldg No P-899 At Chandimandirmil Stn. Submission Date for this Tender is 05-04-2024. Mobile Generator Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42793387
Corrigendum : Tender For Additional/Alternator To Bldg No P-899 At Chandimandirmil Stn
Open Tender
Indian
Haryana
chandimandir
05-04-2024

Tender Details

Tender For Additional/Alternator To Bldg No P-899 At Chandimandirmil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Mar-2024 Revised Page Other 29-03-2024
2 19-Mar-2024 Revised BoQ BOQ 29-03-2024
3 29-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 87000.0 /-
Tender Value
INR 43.50 Lakhs /-

BOQ Items

Name of Work: ADDN / ALTN TO BLDG NO P-899 AT CHANDIMANDIRMIL STN
Sl. No. Item Description
1Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as speicified and directed.
2Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, all as directed.
3Dismantling wrought iron or mild steel work of any description not otherwise provided for, all as directed.
4Powder coated aluminum sections as inframes/ shutter of doors/window/ventilators /partitions,(Openable/Sliding three track)including joinging cleats, glazing clips, rubber neoprene beading, powder coated aluminim snap beading, screws etc.complete all as specified and directed Note : (i) Minimum thickness of power coating shall not be less than 50 micron. (ii) Weight of aluminum section only shall be measuerd and paid. (iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws . (iv) The rate shall be inclusive of neoprene beadings, snap beading, screws, locking roller in case of sliding shutters, arrangement etc. Weight of fitting fixtures will bot be measured for arriving the weight of aluminum section. (v) Glass /wooden panel/ACP sheet shall be measured and paid separately under respective items. (vi) Design as directed by Engineer in charge.
5Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 , complete all as specified & directed by Engineer-in-Charge.
6Poly carbonate coloured sheets as approved, 8mm thick as in roofs as in dome shape, circular / semi circular / arch type shape upto 12 mtr height including self tapping screws / form work / scafolding if required at site to complete the work including adequate size steel screws, washers, nuts, rubber strips/ rubber beading, silicon etc to fill up exisig holes etc aluminium strip/ flat etc as per manufacturer’s instructions,fixed as in repair omplete all as specified and directed.
7Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
8Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
9PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc, fixed in repairs , complete all as specified and directed.
10110mm bore PVC (SWR) bend any radius , fixed in repairs, complete all as specified and directed
11Two coats of synthetic enamel paint on steel and iron surfaces over 10 cm width or girth over a coat of red oxide primer including preparation of new surfacescomplete all as specified & directed.
12Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
13Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
14Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
15Brick work with sub class ‘B’ bricksstraight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
1615mm thick rendering in Cement and Sand mortar 1:4 over brick or concrete surfaces finished even and smooth with using extra cementcomplete all as specified.
17Vitrified ceramic tiles 8-10mm thick (square / rectangular) polished, area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick screed bed in cement mortar 1:6complete all as specified and directed.
18All as per serial item No 17 hereinbefore but on vertical surface over 10mm cm(1:4).
19Dismantling boarding any description fixed in any position with nails complete all as specified & directed.
20Providing & fixing hangers of 6 mm dia. G.I. (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws, complete all as specified and directed
21Supply only4.8mm thick sheet glass fixed to aluminum frame work with standard anodized aluminum snap beading, rubber packing, aluminum screws etc in panels n.exc 0.5 Square metre in each pane, complete all as specified & directed.
22Door closer hydraulically regulated of aluminium extruded section, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, complete all as specified and directed.
23Preparation of new surfaces of any description of wall, facia, ceiling, RCC etc and applying two coats of oil bound destemper over a coat of chalk whiteningcomplete all as specified and directed.
2418/19mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination andother side balancing white lamination, fixed as in shutters, shelves, racks of cabinet box etc with 6mm thick tak wood edging on exposed edges, complete all as specified and directed.
25Continuous (piano) hinges,mild steel, bright finish or electrogalvanised,width of flaps (when open) 40mm, complete all as specified and directed.
2640mm dia cup board knob, fixed with nut and washer of mild steel, bright finished, complete all as specified and directed.
27Preparation of old surfaces of walls and applying two coats of oil bound distemper, complete all as specified and directed
28Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid,bedded or laid bedded pointed in anymortar, all as specified.
29PCC 1:4:8 type D-2 (using 40m graded crushed stone aggregate) as in sub base flooring, finished even ,all as specified and directed.
30Taking down chowkats or frame exc. 1.5 Square metreand n exc 4 Square metre with shutters, without taking off shutters from the frame,complete all as specified and directed.
31Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified.
325mm thick aluminium composite panel sheet (ACP) of colour as approved by Engr In Charge, fixed to wall / ceiling all as specified and directed.
33Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O all as specified and directed.
34Providing and fixing false ceiling at any heights with GRG (Glass fibre reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRCO 0.5 to 0.75 as per IS 8225:1987, Noncombustible as per BS 479(part-4) 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 Gms as per Sqm including both sides) comprising of main T runners of size 15 x 32mm of length 3000mm, cross T of size 15 x 32mm of length 1200mm and secondary intermediate cross T of size 15 x 32mm of length 600mm to form grid module of size 600x 600mm suspended from ceiling using galvanized mild steel item ( galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1100 mm length and L-shaped adjuster of size 85 x 25x 2mm. Galvanised iron perimeter wall angle of size 24 x 24x0.4mm of length 3000mm to be fixed on periphery wall /partition with the help of plasticrawl plug at 450mm centre ot centre and 40mm longdry wall wood screws. The work shall be carried out as per specification, drawings and as per directions of the Engineer-in-Charge.
3512mm thick perforated acoustic gypsum board for wall panelling fixed with screw, jointing tape over and including 50mm glass wool and Gl frame work for comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre fixed to wall cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and directed
36Reinforced cement concrete type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams etc, shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
37Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
38TMT bars for reinforcement, 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
3918-20mm thick granite work (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platfors and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with granite shade with rounding to edges exposed to view complete all as specified and directed.
40Second class hard wood, plain fillet square or rectangular in section clean sawn screwed with scews of sectional area exc 13 Sqcm but not exc 25 Sqcmcomplete all as specified and directed.
416mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work complete all as specified and directed.
42Prepartion of new wodden surfaces of any description, over 10cm in width or girth and applying one or more coat varnish over and including wood filler complete all as specified and directed.
43Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete all as specified and directed.
44Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and directed.
45All as per serial item 44 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed
46All as per serial item 44 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed
47All as per serial item 44 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
48Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed.
49Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed.
50Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose combined two module (ISI marked), complete all as specified & directed.
51Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
52Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge.
53Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed.
54Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting ,complete all as specified and directed.
55LED lamp9 watts, B-22 (inverter bulb)type complete all as specified.
56Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB"s ,MCB"s etcand removing from site, Complete all as specified and directed .
57MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed
58Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 100 to 125Amps & outgoing 4 way having IP 54 protection Complete all as specified and directed .
59MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed.
60Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp compelte all as specified and directed.
61MCB SPN 32 amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB)and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
62MCB, SPN , 240 volt,40 to 63Amps, 10 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed
63MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed
64LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
65Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed.
66Slim LED lights fitting, 2 feet,1x 10W, inverter rechargeable,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
67LED pannel surface mounted o size 2"x2", 36 wattscool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed.
68Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed.
69Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i)For the purpose of measurement, 2 single core of 4 sqmm and one single core earth cable of 4 sqmm cableshall be considered as 1 running metre. (ii)PVC conduit and cutting chases will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
70Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i)For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cableshall be considered as 1 running metre. (ii)PVC conduit and cutting chases will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
71Supply and fixing sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note: (i)For the purpose of measurement, 2 single core of 10 sqmm and one single core earth cable of 10 sqmm cableshall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
72Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed .
7320 to 25 mm dia, rigid non metallic PVC concealed conduit, "ISI marked", inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed .
7432 to 40 mm dia, rigid non metallic PVC concealed conduit, "ISI marked", inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed .
75Round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light, complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
76Engagement light with light red and green LED lamp, fixed as in repaircomplete all as specified and directed.
77Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed.
78Wall mounted fan PVC body, 400mm sweep, 230 volt , AC,quick start torque motor with copper winding complete all as specified and directed.
79Ceiling fans complete with blades, down rods,electronic regulator and accessories, 230 V, 1200 mm sweep. min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
80Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail