Fitting And Installation Of Decorative Light In Front Of Abhay Biswas House G.P-Naxalbari, Under Naxalbari Block
Tender Value
5.99 Lakhs
Estimated cost
Bid Submission
14 Mar 2024
0 days left
EMD
11999
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
naxalbari → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Fitting And Installation Of Decorative Light In Front Of Abhay Biswas House G.P-Naxalbari, Under Naxalbari Block
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) 19mm dia 3mm thick Polythene Pipe |
| 2 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 3 | Supplying and Fixing of 20W, 220V-50Hz, 2000 lumens,LED Gate Light with high surge voltage protection, IP-65 Certification, CCT-3000K having dimension 175x175x225 & CRI-80 and beam angle of 120 degrees. Product Code: Ivon Gate Light LG-0138-20W Make: Sturlite |
| 4 | Supplying and Fixing of 36W, 220V-50Hz, 110 lumens/watt ,LED Street Light with high surge voltage protection, IP-65 Certification, CCT-6500K and beam angle of 120 degrees. |
| 5 | Supplying and Fixing of 50W, 220V-50Hz, 6000 lumens,LED Flood Light with high surge voltage protection, IP-65 Certification, CCT-6500K having dimension 223x227x49 & CRI-80 and beam angle of 120 degrees, P.F.>0.9 |
| 6 | S & D 1.1 kV grade PVC/XLPE Al Armoured Cable of 2 core 10 sq mm Cable (Make: KEI/POLYCAB/HAVELLS/GLOSTER) |
| 7 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables for 2 core x 10 sq mm |
| 8 | Finishing the end of 2C x 10 sq mm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anti corrosive paste & jointing materials |
| 9 | Supplying & Fixing light timer Control Unit (Outdoor Type) with following accessories and wiring with 4.00 sq mm Cu wire (For MCB to Contactor/terminal block), 1.50 sq mm Cu Wire (For control wiring). Suitable size 16 SWG CRCA sheet metal box having min depth 3.5\" and should have adequate strength and space to accomodate the following accessories.i) 32A DP MCB (Make: L&T)- 01 no. as incomerii) Digital Astro Mini time switch (Make- L7T Astro mini Cat no: T2DDT7)- 01 no.iii) 25A-2Pole Power Contactor (L&T: Cat No- CS90240)- 01 no.iv) 20A DP MCB \"C\" curve (Make: L&T)- 01 no. as outgoingv) Toggle Switch (ON-OFF-ON)- 01 no.vi)Outgoing Terminal stud with nut - 02 setsvii) Indication Lamp (R,G)- 02 no.viii) EI Danger Board (6\" x4\")- 01 no.Metal Box should have gasket arrangement inside the door. |
| 10 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI Pipe |
| 11 | Excavation of soil (Morrom Soil) for installation of Earth Electrode and filling & Ramming |
| 12 | S & D of 7 mtr. Long swaged type steel tubular pole as per (410SP-53) with 300mmx300mmx6mm base plateand 1 mtr long 40mm dia GI pole top arm bracket with sleeves, nut etc as required. (Make: Transrail/Wipro/Bansal/Jindal/Utkarsh). |
| 13 | Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly. Upto 9.00 Mtr |
| 14 | Extra on itemsfor providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S&F 25cmx25cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole |
| 15 | S & L of 3-core 1.50 sq mm FR single core multi strand copper cable for conncetion from loop box to fittings through 13mm dia polythene pipe |
| 16 | S & D of LED Street light luminaire 60W, 240 Volts, 50Hz Street Light, Aluminium Die Cast with IP-67 protection and having 120 lm/watt and not less than 6000 lumen with high surge protection. (Make- HPL/Philips/Crompton) and all other accessories |
| 17 | Supplying and Fixing of SMD Rope Lights, 1-phase, 220V, 120 led/ metre,50Hz with adapter arrangement. Colour: Blue, White,Saffron and Green. |
| 18 | Supplying & Fixing of iron Display Board |
| 19 | SGST @ 9% |
| 20 | CGST @9% |
| 21 | CESS @ 1% |
AI Tender Summary
Tender Timeline
Mar 08, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedMar 14, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 16, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender