}

Tender For Supply For Ortho And Dental Implant In Dlnpgmc Ratlam, ratlam-Madhya Pradesh

Government Medical College-GMC has published Tender For Supply For Ortho And Dental Implant In Dlnpgmc Ratlam. Submission Date for this Tender is 29-03-2024. Bath and Body Tenders in ratlam Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42774081
Corrigendum : Tender For Supply For Ortho And Dental Implant In Dlnpgmc Ratlam
Open Tender
Indian
Madhya Pradesh
ratlam
29-03-2024

Tender Details

Tender For Supply For Ortho And Dental Implant In Dlnpgmc Ratlam-- 1 Implants List 2 DHS set*barrel length 38mm,25 mm SS lag screw 22 & 16 mm tread (50 to 115mm in 5mm increment) and top screw & angle 125 to 140 degree plate 3 hole to 18 hole & corresponding4.5 mm screw for plate 3 Pediatric D.H.S. Set SS 4 D.C.S set* 95 degree Plate bareel length 38/25mm with lag screw12.5/8mm from 50 to 115mm and top screw and plate length 4 hole to 24 hole SS4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 holesNote:- 1.The implants listed from Item No. 1 to 3 set include plate,lag screw,top screw and screw for plate so price quotation should be given accordingly2.The implants listed from Item No. 1 to 3 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. 5 Angle Blade Plateset (950) SSBlade size 50, 55, 60, 65, 70 & 75 mm.plate hole4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 holes with screw for respective plate 6 Condylar Buttress Plate with screw ss3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 HolesNote:- The implants listed from Item No. 4 to 5 should be supplied along with the Specific instrumentation required for their insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. 7 Trochanteric Stabilisation Plate to be used with DHS & PFN of varius hole with screw and instrument 8 Contoured Locking Plate for Fracture shaft femur 4.5 mm (Right & Left)- as per AO specifications. 3, 5, 7, 9, 13, (Combi holes) with corresponding screw SS 9 Distal Femur Locking Compression Plate 4.5mm (Right & Left) 4 hole to 18 hole with correspondingscrew SSAnatomical pre-shaped & Contoured with self-tapping Locking Head Screws; with Round Locking Holes for metaphyseal portion of plate & Combiholes for shaft of plate.should be supplied along with the Specific instrumentation required for their insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. 10 Medial & Lateral Proximal Tibial Buttress PlateRt & Lt (T- & L- shape)- as per AO specifications. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes with corresponding screw SS 11 Proximal Medial Tibial Plate 3.5 mm Rt & Lt with corresponding screw SS1. Anatomically pre shaped and low profile.2. Two different plate design for left and right side with indication on side of plate.3. Plate should have 2 mm holes for Proximal Fixation with k-wire and sutures for meniscal repair.4. Holes should accept 3.5 mm locking head or 3.5 mm Standard Cortical Screws from 4 to 20 holes with increment of 2 holes. 12 Proximal Lateral Tibial Locking Plate for 4.5 mm screws Rt & Lt with corresponding screw SS1. Anatomically pre shaped and low profile design, two different plate design for left and right with indication on plate.2. Round metaphyseal locking holes and combi holes in shaft portion for locking and standard screws.3. Different angulation in proximal part of the plate to avoid primary and secondary loss of reduction.4. Should be compatible for less invasive technique.5. Holes should accept 5 mm locking head or 6.5 mm standard cancellousl screws from 5 to 13 holes 13 L C P 3.5 mm Proximal Lateral Tibial Plate Rt & Lt with corresponding screw SS1. Anatomically pre shaped and low profile,.plate should have three to four 2 mm holes in most proximal part for fixation with k-wire and suture .2. Should have holes for four convergent 3.5 mm locking screws designed to allow locking screws to support medial fragment,plate design should allow screws in head of the plate to support the subchondral bone.3. Shaft portion should have combi holes to accept 3.5 mm locking head screws and3.5 mm standard cortical screw.4. Should be available in left and right sides with 4 to 16 holes with 2 hole increaments 14 posteromedial anatomicalproximal tibia plate 3.5mm wth corresponding screw1. Anatomically pre shaped and low profile.2. Two different plate design for left and right side with indication on side of plate.3. Plate should have 2 mm holes for Proximal Fixation with k-wire. 15 L- Buttress Plates for Right & Left side wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 16 L- Buttress Locking Plates for Right & Left side 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes wth corresponding screw 17 T- Buttress Plates for Right & Left side wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 18 T- Buttress Locking Plates for Right & Left side 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes wth corresponding screw 19 Hockey Plate For Tibia (Right & Left) 5, 7, 9, 11, 13, 15, 17 Holes wth corresponding screw 20 Hockey Locking Plate For Tibia (Right & Left) 5, 7, 9, 11, 13, 15, 17 Holes wth corresponding screw 21 Contoured Medial/ Antero-lateral Plate for Lower end Tibia 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes wth corresponding screw 22 Distal Medial Tibial Locking Plates 2.7/ 3.5 mm wth corresponding screw1. Anatomically pre-shaped and low profile and specific for right and left side with Indication of side on plate, compatible with less invasive fixation.2. Rounded edges screw heads should be received into Distal section of plate to allow multiple locking head screw placement of 2.7/ 3.5 mm to provide adequate fixation of metaphyseal portion of tibia, and size 4 to 14 holes with increment of 2 holes. 23 Anterolateral Distal Tibial Locking Plate 3.5 mm wth corresponding screw1. Anatomically pre shaped and low profile and specific for right and left side with indication of side on plate. Plate should have head holes to accept 3.5 mm Locking head or standard cortical or 4 mm standard cancellous screw.2. Head should be received into the plate.3. Size from 5 to 21 holes with increment of 2 holes 24 Clover Leaf Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 25 Clover Leaf Locking Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 26 Cobra Head Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 27 Cobra Head Locking Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 28 Hook Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 29 Hook Locking Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 30 Proximal Humerus Locking Plate (PHILOS Plate) wth corresponding screw Anatomically pre-countoured platesShould have precisely fitting sleeves for precision placement of screws. Should accept 3.5 mm Locking Head Screws.The Screws provided should be available from 26 to 60 mm length.The head of the plate should have holes for securing tuberosities to the plate with sutures.Should have low profile of the screws heads to prevent tissue irritation. 3, 4, 5, 6, 7, 8, 9, 10, 12 Holes 31 Contoured Locking Plate for Distal End Humerus medial and lateral coloumb 3.5 mm wth corresponding screw(Prices to be quoted separately for the following 2 items)1. Anatomically pre-countoured plates for Distal Medial Humerus for anatomical fit with left & right version Should have precisely fitting sleeves for precision placement of screws. Should accept self-tapping Locking Head Screws.The shaft portions of the plate should have Combi holes.Should have low profile of the screws heads to prevent tissue irritation. 3, 5, 7, 9 & 14 Holes2. Dorso-lateral Plates with & without Lateral support with right & left versions Anatomically pre-countoured platesThe shaft portions of the plate should have Combi holesShould have low profile of the screws heads to prevent tissue irritation. 3, 5, 7, 9 & 14 Holes 32 Calcaneal Plate with corresponding screw SS. 33 Calcaneal Locking Plateswith corresponding screw SS. 34 Clavicle Locking Plate- Antero-superior type with corresponding screw SS. 35 Clavicle Locking Plates- Anterior type with corresponding screw SS. 36 Clavicle Hook Plate with corresponding screw SS. 37 Elise Plate/ Contoured Plate for Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes with corresponding screw SS. 38 Locking Elise Plate/ Contoured Locking Plate for Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes with corresponding screw SS. 39 H-Plate with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10 Holes 40 Y- Plate with corresponding screw SS..3, 4, 5, 6, 7, 8, 9, 10 Holes 41 D.C.P. Small with corresponding screw SS..4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 42 D.C.P. Narrow with corresponding screw SS.4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 43 D.C.P. Broad with corresponding screw SS..4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 44 L.C.D.C.P Small with corresponding screw SS..3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 45 L.C.D.C.P. Narrow with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 46 L.C.D.C.P. Broad with corresponding screw SS..3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 47 L.C.P Small with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 48 L.C.P. Narrow with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 49 L.C.P. Broadwith corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes 50 Semitubular Plates 4.5mm.with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 51 Semitubular Plates 3.5mm with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 52 1/3 rd Tubular Plates 4.5mm with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 53 1/3 rd Tubular Plates 3.5mm with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 54 Quarter-Tubular Plates 2.7 mm. 3, 4, 5, 6, 7, 8 Holes with corresponding screw SS. 55 Straight Mini Plates 2.0 mm & 1.5 mm. 20 Holes with corresponding screw SS. 56 Reconstuction Plates 3.5mm with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 57 Reconstuction Locking Plates 3.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes with corresponding screw SS. 58 Reconstuction Plates 4.5mm with corresponding screw SS. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes 59 Reconstuction Locking Plates 4.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes with corresponding screw SS. 60 16 mm threaded Cannulated Cancellous Screws 4 mm.25, 30 ….115 mm, in 5 mm increment. 61 32 mm threaded Cannulated Cancellous screws 4 mm25, 30…….115 mm, in 5 mm increment. 62 Fully threaded Solid Cancellous Screws 4 mm25, 30…….115 mm, in 5 mm increment 63 16 mm threaded Solid Cancellous Screws 4 mm25, 30,…….115 mm, in 5 mm increment 64 32 mm threaded Solid Cancellous screws 4 mm25, 30,…….115 mm, in 5 mm increment 65 Fully threaded Cannulated Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 66 16 mm threaded Cannulated Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 67 32 mm threaded Cannulated Cancellous screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 68 Fully threaded Solid Cancellous Screws 6.5 mm (20 TPI)25, 30,…….115 mm, in 5 mm increment 69 16 mm threaded Solid Cancellous Screws 6.5 mm (20 TPI)25, 30,…….115 mm, in 5 mm increment 70 32 mm threaded Solid Cancellous screws 6.5 mm (20 TPI)25, 30,…….115 mm, in 5 mm increment 71 Fully threaded Locking Cannulated Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 72 16 mm threaded Locking Cannulated Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 73 32 mm threaded Locking Cannulated Cancellous screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 74 Fully threaded Locking Solid Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 75 16 mm threaded Locking Solid Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 76 32 mm threaded Locking Solid Cancellous screws 6.5 mm25, 30,…….115 mm, in 5 mm increment 77 Cannulated Cancellous Screws of 4mm & 6.5mm in 16mm & 32mm Thread from length 30 to 130mm in (5mm, increment) TITANIUM 78 Washer Round, 13 mm, 10 mm, 7.0 mm, 4.5 mm. 79 Spiked Washer, 13.5 mm, 8.0 mm, 3.2 mm. 80 Nut for 4.5 mm Cortex Screw. 81 Malleolar Screw,4.5 mm 15, 20, 25,………100 mm 82 Herbert’s screwNote:- The implants listed from Item No. 18 to 97 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant-instrument fitting. 83 Interlocking Femur Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm 84 Interlocking Solid Femur Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm 85 Recon Nail (Right & Left) (As per AO specifications) with Compatible Locking BoltsDiameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm 86 Proximal Femur Nail (P. F. N.)LONG right & left (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm 87 Proximal Femur NailSHORT9mm to 13mm right & left 88 Trochanteric Entry Femur Nails with Compatible Locking Bolts Diameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm 89 Supracondylar Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length10 mm150,200,250,300 mm11 mm150,200,250,300 mm12 mm150,200,250,300 mm 90 Interlocking Tibia Nail (As per AO specifications) with Compatible Locking Bolts DiameterLength8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm 91 Interlocking Distal Tibia Nail (As per AO specifications) with Compatible Locking Bolts DiameterLength8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm 92 Interlocking High/Upper Bent Tibia Nail (As per AO specifications) with Compatible Locking BoltsDiameterLength8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm 93 Interlocking Solid Tibia Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm 94 Expert Tibial Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm 95 Interlocking Humerus Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length6 mm200 to 300 mm7 mm200 to 300 mm8 mm200 to 300 mm 96 Interlocking Bolts (As per AO specifications) Diameter Length2.9 mm12 to 30 mm3.9 mm14 to 48 mm4.9 mm16 to 120 mm 97 Proximal Bolt RECON (As per AO specifications) DiameterLength6.4 mm60 to 110 mm 98 Proximal Bolt RECON Cannulated (As per AO specifications)Diameter Length6.4 mm60 to 110 mm 99 Proximal Bolt P.F.N. Cannulated (As per AO specifications) Diameter Length6.4 mm60 to 110 mm8.0 mm60 to 120 mmNote:- The implants listed from Item No. 98 to 112 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. 100 Kuntscher’s Nail7, 8, 9, 10, 11, 12 mm diameterNote:- The implant listed in Item No. 113 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. 101 V-NailNote:- The implant listed in Item No. 114 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. 102 Square Nail for Ulna2, 2.5, 3, 3.5 mm diameter 103 Square Nail for Radius2, 2.5, 3, 3.5 mm diameterNote:- The implants listed in Item No. 115 & 116 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant-instrument fitting. 104 Rush Nail.2.5, 3, 3.5 mm diameter.Note:- The implant listed in Item No. 117 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. 105 Ender’s Nail.3.5, 4, 4.5 mm diameter. 106 Titanium Elastic Nailing System (TENS).Note:- The implant listed in Item No. 118 & 119 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. 107 Non fenestrated bipolar prosthesis37, 39,…………….51, 53 mm 108 Fenestrated bipolar prosthesis37, 39,…………….51, 53 mm 109 Thompson Endo-Prosthesis.37, 39, 41, 43, 45, 47, 49, 51, 53 mm.Long stem Austin moore prosthesis37, 39,……………………..51, 53 110 Short stem Austin moore prosthesis37, 39,……………………..51, 53 111 Austin Moore Endo-Prosthesis.37, 39, 41, 43, 45, 47, 49, 51, 53 mm. 112 Austin Moore Endo-Prosthesis XL Finish. 37, 39, 41, 43, 45, 47, 49, 51, 53 mm.Note:- The implant listed from Item No. 120 & 127 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. 113 Bone cement (Price tobe quoted separately for the following 4 items)1.High viscosity Poly Methyl Meth-Acrylate 40gms with working time of 5-6 min.2.Medium to low viscosity Poly Methyl Meth-Acrylate 40gms.3.High viscosity Poly Methyl Meth-Acrylate 40gms with working time of 5-6 min with Gentamycin.4.Medium to low viscosity Poly Methyl Meth-Acrylate 40gms with Gentamycin.Cement Gun should be provide by the dealer as loan instruments without extra charges during Total Hip Replacement surgeries.Cost of Disposable Nozzle to be provided separately . 114 Cement stopper size …7,8,9……to………….16mmCalcium sulphate bone substitutes 115 Granules & Wedges 1.G Bone Synthetic HAgranules 10cca. B tri Calcium phosphate granules 1.4 to 2.8mm per porosity 60% Bone Substitutes-5gm, 10gm, 20gm 116 Cemented TotalHip Replacement THR -*Stem should be as per Standard Design with metal of sufficent strength to withstand life-time use in the patients. Different sizes and offsets to be quoted.*Cup of Polyethylene High Density High Molecular Weight Highly Crosslinked with anti-oxidative manufacturing & storing process (to increases the shelf life) with different offsets.*Cup Sizes : - 38 to 60 mm Outer Diameter and Odd Numbers Sizes*Cemented THR with Polished taper stem with tapering on both planes made of Cobalt Crome Material*Should be having different sizes to cater for small stature, thin built patient& dysplastic hip as well as large hips.*Modularity for neck length and head sizes 22, 28, 32 and 36 mm.*Acetabular component should be metal backed as well as all poly.*Metal back should have modularity to use polyethylene as well as Ceramic.*All Polyethylene liner as well as cups should be made of highly Cross- linked High Molecular Weight polyethylene with measures to prevent Oxidation .*The metal used for stem should be of high tensile strength and fatigue strength like Cobalt-Chrome.Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Hips should have modularity for interchangibility of cups, heads and stems.7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents 117 Uncemented T.H.R.*The stem of the Femoral Component should have Double Taper Geometry with Plasma Hydroxy-Appetite coating with at least thickness of the coating of100to200micronsorPorouscoatedwithsufficientporesizeand thickness of porous coating to have optimal bony ingrowth.The Stem should have narraow Distal tip along with highly polished Neck of Angle 135 and 126 Degrees*The stem should accept metal (Cobalt- Chrome) as well as Ceramic Head (Bilox Delta , Zirconium ,Alumina with Zirconia)*There should be modularity regarding size of head & neck length.*Cup of Polyethylene High Density High Molecular Weight Highly Crosslinked with anti-oxidative manufacturing & storing process (to increases the shelf life) with different offsets. Preferably the cup should have longer posterior wall with flange for cement pressurization.*Metal Back cup with Porous Coating and Stikite Coating Resistance for better fit and coating with design to lock into the host bone to provide primary fixation with provision for screw fixation*Should accept liners made up of Highly Cross-Linked High Molecular Weight Poly-Ethylene & Delta Ceramic (Alumina with Zirconia).*The Femoral Head should be made up of Cobalt-Chrome or Delta-Ceramic and ZIrconium and should have different Neck length.*Metal screws for fixation of metal cup.*The whole system should have modularity & inter-changibility.*The Prices should be quoted separately for stems, cups liners of polyethylene and ceramic as per specifications mentioned above and as well as for metal & ceramic heads of different sizes as per specifications quoted above. 118 uncemented T.H.R. (Ceramic on poly)a. HA Coated femoral stem of different size b. ceramic headfrom 28mm to 36mm with variable neck length c.uncemented acetabulam cup HA coated with option for screw for head 28mm to 36mm with same cup d. acetabular highly cross link poly cup liner different size should accommodate 28mm to 36mm head e. corresponding cup screw Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Hips should have modularity for interchangibility of cups, heads and stems.7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents 119 Hybrid T.H.R a.SS Cemented moduler stem (small medium large double tappered highly policed collar less self centering variable offsets )b.moduler enternal head variable size with variable neck length.C. HA cottated Acetabulam cup with screw of different size d.Highely cross link poly cup liner different size e. stem centralizer f. cement restrictor g. Screw for cup Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Hips should have modularity for interchangibility of cups, heads and stems.7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents 120 Revision T.H.R.*Revision stem, Modular Straight Cylindrical And Double /Triple Tapered, Porous coated having Slines for cortical fit in the size of 190 ,240 and 300 different lengths.*The diameter and length of the stem should be variable with a provision to address curve of the femur with long stem.*Modularity should be provided for version, offsets, calcar loss and neck length.*Revision cups to be provided with large diameter of upto 65 mm with augments for bone loss in the form of cages and metal rings, as well as, wedges. All these to be quoted separately.Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Hips should have modularity for interchangibility of cups, heads and stems.7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents 121 Acetubalar mesh SS 122 Acetubalar cage of various size 123 Trabecular Acetubalar augment variuous size & shape 124 Trarbecular Acetubalar screw various size 125 Regular Shoulder prosthesis & Reverse Shoulder Prosthesis (Prices to be quoted separately)35 mm, 39 mm 126 Total elbow prosthesis Regular and custom made 127 Radial head prosthesis 16 mm x 4 mm x 6 mm18 mm x 4 mm x 6 mm18 mm x 5 mm x 6 mm20 mm x 5 mm x 8 mmNote:- The implants listed in Item No. 134 to 136 should always be supplied along with the suitable instrumentation (for which no extra charges/rent will be levied),which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. 128 Continuous loop endobutton - Titanium madeContinuous loop endobutton One size titanium button with multiple pre-measured loop sizes of 15, 20, 25, 30,35, 40mm lengths.Preloaded with polyester braid suture (#5 leading suture & #2 flipping suture) 129 Low- Profile Cancellous Screws Titanium madeLow profile head to reduce soft tissue irritation6.5 mm diameter screw 25, 30, 35, 40mm lengths 130 Spiked and suture WashersWasher 14 and 18 mm 131 Tibial Post Fixation Screw Titanium madeDia 6.5 mm and 30 mm length 132 Shaver Blades and Burrs (SS alloy / platinum tip)Single cutting: Razor sharp toothed inner blade No teeth on outer window4mm, 4.5 mm 5mm 5.5mm Straight and angled Double Cutting: The narrow gap between inner and outer cutting surfaces4mm, 4.5 mm 5mm 5.5mmStraight and angledResector: 4mm, 4.5 mm 5mm 5.5mmStraight and angledBurrsBarrel burrs 4mm, 4.5 mm 5mm 5.5mm 6 flute and 12 fluteRound Burrs 4mm, 4.5 mm 5mm 5.5mm6 flute and 12 flute 133 Spiked Ligament Staple Titanium made Small and large 134 Cannulated Cross Pin Titanium made 30mm 135 Cannulated Interference Screws- Roundhead Titanium/Bio absorvable? Standard 4.5mm hex for easier insertion and removal.?in diameters 8mm, 9mm, 10mm and 11mm.?in lengths 20mm, 25mm, 30mm and 35mm. 136 Cannulated Interference Screws- Fully Threaded Titanium/Bio absorvable?in diameters 8mm, 9mm, 10mm and 11mm. in lengths 20mm, 25mm, 30mm and 35mm 137 Braided Composite suture (i.e. Bio Fiber/fiber wire)? multi-strand,longchainultra-highmolecularweightpolyethylene (UHMWPE) core with a braided jacket of polyester and UHMWPE? Tapered ,cutting ,reverse cutting and diamond end ,3/8 circle and 1/2 circle?white; white/blue; white/green colours.? USP size 2/ EP size 5.? length 38 inches/90 cms. 138 Braided polyester suture( i.e.Ethibond )?braided, sterile, surgical suture composed of Poly (ethylene terephthalate).?prepared from fibers of high molecular weight, long-chain, linear polyesters having recurrent aromatic rings as an integral component.? coated with polybutilate or poly {oxy-1, 4 butanediyloxy (1, 6-dioxo-1, 6 hexanediyl)? 2-0 and 5-0 with 4 strands 139 5mm synthetic, braided, non-absorbable suture (i.e. Mersilene tape) from fibers of high molecular weight, long-chain, linearpolyesters 140 Titanium Interference screws for ACL repair. Sizes 8 mm, 9 mm, 10 mm, 11 mm, 12 mm. 141 Titanium Endo-Button. 142 Titanium Endo-Disc.Note:- The implants listed from Item No. 137 to 151 should always be supplied along with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. 143 A. O. Open Clamps. 2.5, 3.5, 4.5 mm. 144 A. O. Closed Clamps. 2.5, 3.5, 4.5 mm. 145 Cylindrical/ Universal Clamps. 2.5, 3.5, 4.5 mm. 146 Rod to Rod Clamp. 147 Transverse Clamp. 148 Cortical Schanz Pin 4.5 mm. 149 Cortical Schanz Pin 4.0 mm. 150 Cortical Schanz Pin 3.5 mm. 151 Cortical Schanz Pin 3.0 mm. 152 Cortical Schanz Pin 2.5mm. 153 Cancellous Schanz Pin 5 mm. Cancellous Schanz Pin 6 mm. 154 Tubular Rod. 155 Connecting Rod.4, 5, 8, 10, 11 mm diameter.4”, 6”, 8”, 10”, 12”, 14”, 16”, 18”.100- 200 mm with 50 mm of increment. 156 A.O. Type External Fixator R/U. 157 Finger Distractor. 158 Radius Ulna Distractor. 159 Rail Road Fixator for Femur/ Tibia.Note:- The implants listed from Item No. 152 to 169 should always be supplied along with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. 160 Illizarov’s Ring Fixator. Half Ring.80, 100, 120, 140, 160, 180, 200, 220, 240 mm. 161 Italian Femoral Arches 900, 1200.80, 100, 120, 140, 160, 180, 200, 220, 240 mm. 162 Multiple Fixation Clamps. 163 Schanz Pin Fixation Bolts. 164 Oblique Supports. 165 Threaded Rods. 8 mm diameter.75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450 mm. 166 Telescopic Rods.75, 100, 125, 150, 175, 200, 250, 300, 350, 400 mm. 167 Male & Female Post. 2, 3, 4, 5 hole set. 168 Male & Female Hinges. 169 1 hole set. 170 Connection Plates. 5, 6, 7, 8 holes. 171 Twisted Plates. 5, 6, 7, 8 holes. 172 Illizarov’s Wires Bayonet Type. 1.5, 1.8, 2.0 mm. 173 Illizarov’s Wires Olive Type. 1.5, 1.8, 2.0 mm. 174 Connecting Bolt. 175 Connecting Nut 10 mm. 176 Wire Fixation Bolts Cannulated. 177 Wire Fixation Bolts Slotted.Note:- The implants listed from Item No. 170 to 186 should always be supplied along with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. 178 JESS External fixator set. 179 Pelvic C Clamp. 180 Nails for Pelvic C Clamp. 181 Steinman Pin.3, 3.5, 4, 4.5, 5 mm. 182 Denham Pin.3, 3.5, 4, 4.5, 5 mm. 183 Kirschner Wire double ended Trocar Tip/ Threaded Tip. Diameter 1, 1.5, 2, 2.5, 3 mm.Length 6”, 9”, 12”.Note:- The implants listed in Item No. 192 should always be supplied along 184 with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. 185 S.S. Wire Reel. 16 to 28 Gauze.Note:- The implants listed in Item No. 193 should always be supplied alongwith the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. 186 Knowel’s Pin. 187 A.M. Pin. 188 Gigli Saw Wire. 189 Titanium Pedicle Screw & Rod Set (MRI- compatible). 190 Titanium Cage (MRI- compatible). 10mm, 13mm, 16 mm, 19 mm. 191 Titanium Staple (MRI- compatible). 192 Titanium Transverse Connector (MRI- compatible). 193 Titanium Mono- Axial Screws (MRI- compatible).5.3 mm 30 mm, 35 mm, 4 0 mm, 45 mm.6.0 mm 30 mm, 35 mm, 40 mm, 45 mm. 194 Titanium Poly- Axial Screws (MRI- compatible).5.3 mm 30 mm, 35 mm, 40 mm, 45 mm.6.0 mm 30 mm, 35 mm, 40 mm, 45 mm. 195 Hartsheel Implants for Spine (MRI- compatible). 196 Cervical Plates (MRI- compatible). 197 Harrington Rod System (MRI- compatible). 198 Bipolar Prosthesis with modularityBipolar with fixed neck length Component TypeSize(i) Stem 1. Modular Small,medium,large(ii)Head 1. Modular Size 39,41,43……….59 mm 199 Varying neck lengths with increments of 2.5 mm to 3.5 mm.Component TypeSize(i)Stem Standard(ii) Head39,41,43……….59 mm 200 Mono axial locking screw 4.5 mm, 5.5 mm, 6.5 mm diameter 30-50 mm with 5 mm of increament 201 Mono axial locking screw 6.5 mm diameter (Iliac screw) 60 – 75 mm with 5 mm of increament 202 Cross link (Inter connector) 5 mm 203 Cervical H-plate ordinary hole 4 hole 20 – 35 mm with 2.5 mm of increament 204 Cervical H-plate ordinary hole 6 hole 35 – 55 mm with 2.5 mm of increament 205 Cervical H-plate ordinary hole 8 hole47.5 – 65 mm with 2.5 mm of increament 206 Cervical spine locking plate 5 hole 25, 29, 33 mm 207 Cervical spine locking plate 8 hole 37, 41, 45 mm 208 Drummonds wire without button 209 Drummonds wire with button 210 Sublaminar wire 12” Note:- The implants listed from Item No. 197 to 217 should always be supplied along with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting.Titanium plates with bar & Without bar 4 Hole titanium plate (1.5mm, 2mm, 2.5mm) 211 Disposable Pulse Lavage Tubings. 212 BASIC Total Knee Replacementa.femoral components co-cr various sizes b.Tibial components cocr variable size c.Tibil insert variable sizesd.patellar button various sizee.Mobile bearing & fixed bearing Kneesf.Cruciate-Retaining/ Cruciate-Scarificing Designs/ Deep Dished Design of Highly Cross Link Materialg.All components should be separately quoted.Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented kneeshould have modularity for interchangibility 7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents 213 Total Knee Replacement All polyethylene &metal backMobile bearing & fixed bearing KneesHighly polished and Asymetric tibial tray to prevent back wear in Fixed bearing knee and Natural fit to the TibiaAdequate sizes & modularity of Tibial insert to be provided.Pateller component should to be quoted separatelyCruciate-Retaining/ Cruciate-Scarificing Designs/ Deep Dished Design of Highly Cross Link MaterialFor revision,Constraint designs with Intramedullary extension .Designs for achieving high flexion.All components should be separately quoted.Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Knee should have modularity for interchangibility 7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents 214 antibiotic spacer mould for infected T.H.R all size & disposable 215 antibiotic spacer mould for infected T.K.R all size & disposable 216 Consumable for T.H.R a.HIP U drape plastic imperviousb.Cling drapec.pulse lavage disposable d.Coutery pencil & Suction cannula disposable 217 Consumable for T.K.R a.knee O drape plastic imperviousb.Cling drapec.pulse lavage disposable d.Coutery pencil & Suction cannula disposabl 218 Tibial tunnel guide system for ACL Reconstruction (should have locking system with variable angleadjustment from 35 to 60 degree 219 Cannulated flower tip drill bit with laser making for calculation of bone tunnel length for ACL reconstruction Size 5,6,7,8,9,10,11 mm 220 Femoral off set guide for 4,5 ,6,7 7 mm 221 Drill tip graft passing pin 2.4mm 222 Drilling wird 2.4mm 223 Graft preparation board 224 Tedon stripper, 7mm dia close ended 225 Thickness tester 226 shaver blades all sizes 227 suture disc 228 bio screw driver 229 ACL repair Implant Bioabsorbale interference screw size 7-11mm, L 20-30mm 230 Tedon stripper, 7mm dia close ended 231 Thickness tester 232 shaver blades all sizes 233 suture disc 234 bio screw driver 235 ACL repair implants Titanium with rounded thread soft cannulated interference screws dia 7-10mm L20,25,30mm 236 ACL Repair Implant Bioabsorable interence screw size 7-11mm, L20-30mm 237 ACL repair implant tibial biobsorable interferencescrew with proximal slop to flush fix in anterior tibial cotex size 7-11mm,L20-30mm 238 shoulder cannula disposable 239 3 mm knotted bio absorabable anchor 240 2.3 mm knot less bio-absorabable anchor 241 2.9mm knot less bio-absorabable anchor 242 2.3mm knot less PEEK anchor 243 2.9mm knot less PEEK anchor 244 3.5 mm knot less bio-absorabable anchor 245 3.5mm knot less PEEK anchor 246 5.5mm knot les PEEk anchor 247 ALL PEEk anchor for double & single row cuff repaid Dia4,5,5.5,&6.5mm 248 Suture passer 45 degree left and right 249 suture passer 90 degree left and right 250 Suture shuttle needle 251 UHMW #2 number white/coloured suture with needles 252 UHMW #2 number stripped colour with needles 253 Acromio-clavicular joint dislocation repair system having button on one side & suture disc on other side connerted with suture wire 254 Radio frequency ablation probe (different angle) for arthroscopy, disposable (please quote rate for one radio frequencyablation probe only and machine generator to be provided by conpany for ablation probe use for surgem) 255 The Stem should be Collerless Fully Porous Coated with Double /Triple Tapered Design 256 The Femoral Stem should be available in Standard and Extended Offset options 257 The Stem Should be available in All Sizes starting from 01 up to 8 ,total 12 sizes 258 The Tapered Geometry should have option of 12/14 design and compatibility of Heads 259 The Femoral Heads Sizes should be available in All Sizes from offset -3 ,0,+4,+8 and +12 260 The Femoral Heads should have option of All Material Includes Metal Heads/ Cobalt Crome / Oxinium and Bilox Delta Heads 261 The Acetabular Poly Liner should have Highly Cross link Poly Ethylene liner 262 The Highly Cross link Poly Ethylene should have 20 Degree Extender Lip on Posterio Superio Wall of Liner 263 The Acetabular Shell Should have Three holes for Screw Fixation 264 The Acetabular Shell should have Stikttie Coated Titanium Shell Sizes from 42 to 64 mm 265 The Acetabular Shell Should have Taper Lock Design and Coampatible to accommodate 6.5 mm Screws self Locking 266 The Implants Should have Registry Follow up Data and USFDA , CE Certified 267 The Acetabular Shell should have compatibility to accommodate Ceramic Liner made Bilox Delta Material 268 The Femoral Component Made of Cobal Crome with Hiflex Design 269 The Femoral Component Should Have Low Anterior Flange to reduce Notching and Better Fit 270 Posterior Stabilised Design with Asymetric Tibial Design to Mimic Natural Fit of Tibial Component 271 The prosthesis should have Option of Cruciate Retaining Design 272 The Poly Liner Should have Highly Cross Link Poly 273 The Constraint Liner Should be Compatible with Primary Tibial Base Plate 274 The Primary Tibial Base Plate should be compatibale with Extended Rods Option size from 100 mm to 150mm 275 All the TKR Instruments should have Anterior Referencing and Posteiror Referencing 276 The Insert /Poly Thickness should have 9mm ,11mm,13mm,15mm,18mm and 21mm 277 The Primary Prosthesis should have Titaniyum Base Plate with Highly Polished surface to reduce Wear backside poly 278 One Pack of Bone Cement 40gm to be provided along with One TKR Set 279 The Construct should adhere the Guidelines of NPPA 280 Drill bits (1mm) 281 Drill bits (1.5mm) 282 Drill bits (2mm) 283 Drill bits (2.5mm) 284 Stainless Steel Wire (26 Gauge) 285 Erich arch bar 286 Titanium plates with bar & Without bar 4 Hole titanium plate (1.5mm, 2mm, 2.5mm) 287 Titanium plates with bar & Without bar 2 Hole titanium plate (1.5mm, 2mm, 2.5mm) 288 Titanium plates with bar & Without bar Continous plate titanium plate (1.5mm, 2mm, 2.5mm) 289 Titanium plates with bar & Without bar L Shaped titanium plate (1.5mm, 2mm, 205mm) 290 Titanium screw (should be cross hole) 1.5mm (4mm, 6mm, 8mm, 10mm) 291 Titanium screw (should be cross hole) 2 mm(4mm, 6mm, 8mm, 10mm) 292 Titanium screw (should be cross hole) 2.5mm (4mm, 6mm, 8mm, 10mm)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Mar-2024 Corrigendum Technical Bid 29-03-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail