| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-05-2024 | Corrigendum 4 | Date | 31-05-2024 |
| 2 | 14-05-2024 | Corrigendum 3 | Technical Bid | 31-05-2024 |
| 3 | 27-04-2024 | Corrigendum 2 | Technical Bid | 17-05-2024 |
| 4 | 10-04-2024 | Corrigendum 1 | Date | 17-05-2024 |
| Sl. No. | Item Description |
| 1 | Part-01: Construction of Providing/ supplying, lowering, Laying and Jointing of DI, Cluster pump to OHSR, OHSR to VTC and Intra Village |
| 2 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled endplates/coils,confirmingtoIS3589-2001oritslatestrevision/ amendments,forfollowingthicknessandinsidediameter,including all taxes (Central and local), transportation and freightcharges, inspectioncharges,loading/unloadingcharges, includingcostof labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulictesting,disinfection,commissioningetc.complete asper technicalspecificationsanddirectionofEngineer-in-charge; (excluding earthwork, internal lining and outer coating).Note:Providingandfixingofallrequisitespecialsasperdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 3 | 100mm dia- 5mm thk |
| 4 | 150mm dia- 5mm thk |
| 5 | 200mm dia- 5mm thk |
| 6 | 250mm dia- 5mm thk |
| 7 | Providing, lowering, laying in trenches aligning fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S& pipes as per IS:8329-2000 (amended up to date) with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in charge. (excluding earth work)Note: Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.MS/ DI K-7 |
| 8 | 100 mm |
| 9 | 150 mm |
| 10 | 200mm |
| 11 | 250mm |
| 12 | Providing, lowering, laying in· trenches, aligning, fixing in position and jointing DuctileIron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000(amended uptodate), withinternal cement mortar lining, suitable for potable water with rubber ring (EPDM) . joints as per IS: 5382-1985 including all taxes (Central and local), transportation andfreightcharges, inspection charges,loading/ unloading charges, including cost of labour and material, specials (Tee, bendetc.) tisfactory hydraulic testing, disinfection etc.complete as per technical specificationsand direction of Engineer-in-charge. (excludingearth work).Note :Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurementof the item and shall not be paid separately |
| 13 | 150 mm |
| 14 | 200 mm |
| 15 | 250 mm |
| 16 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes (PE-80/ PN-6) as per IS-4984: 1995 (amended upto date) withnecessaryjointingmateriallikemechanicalconnectors, i.e.thread/insertjoint/quickreleasecouplerjoint/compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electrofusionweldingmethod,includingalltaxes,transportation andfreight charges, inspectioncharges, loading/unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer in-charge of following class and diameter. (excluding earth work). Note:Providingandfixingofallrequisitespecialsasperdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. HDPE PE-80/ PN-6 PIPES |
| 17 | 75mm |
| 18 | 90 mm |
| 19 | 110 mm |
| 20 | 125 mm |
| 21 | 140 mm |
| 22 | 160 mm |
| 23 | 180 mm |
| 24 | 200 mm |
| 25 | 225 mm |
| 26 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means intrenchesofrequiredwidthandgradientforlayingandjointingofpipeline including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to1.5Mtr.includingtakingouttheexcavatedsoil,andthenreturningthesoilas required in layers not exceeding 20cm in depth including consolidating each deposited layerby ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil |
| 27 | Ordrinary Soil @50% |
| 28 | Ordinary Rock @25% |
| 29 | Hard Rock(Blasting prohibited) 25% |
| 30 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6 thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and coissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 31 | 80 mm |
| 32 | 100 mm |
| 33 | 125 mm |
| 34 | 150 mm |
| 35 | 200 mm |
| 36 | 250 mm |
| 37 | Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work..Scour Valve |
| 38 | Manually operated class PN 1.0 |
| 39 | 80 mm dia |
| 40 | 100 mm dia |
| 41 | 150 mm dia |
| 42 | SITC of Bulk Flow Meter with removable mechanism class \"B\" confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 43 | 80mm dia |
| 44 | 100mm dia |
| 45 | 125mm dia |
| 46 | 150mm dia |
| 47 | 200mm dia |
| 48 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS, Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring- EPDM/NBR ,Ends flanged according to IS: 6418, Fastners - CS, All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinkingwater) applied inside and outside. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 49 | 40 mm |
| 50 | 50 mm |
| 51 | 80 mm |
| 52 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double ActingKinetic Air Valvewith isolatingSluiceValveofapproved makesfor following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron asperIS:210-FG200,Float-StainlessSteelAISI304/IS:3444, FloatGuide- HBT1.HP Orifice-HTB2/ SS,Bodyseatring- Leadedtinbronze/SS .Sealring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all mateial, labour,testingandcommissioningasperTechnicalSpecificationsandasper direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. Clas PN-1.0 |
| 53 | 40 mm |
| 54 | 50 mm |
| 55 | 80 mm |
| 56 | Providing, lowering, aligning and fixing in position DI D/F Diaphragm type Pressure Reducing / Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body & Bonnet - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or ASTM A 536, Diaphragm and Resilient seal disc - Flexible, non- wicking nylon fabric reinforced synthetic elastomer -Buna-N / EPDM (FDA / WRAS approved), Body Seat Ring - Cast stainless steel ASTM- A 351 GR. CF8M / AISI- 316, raised, replaceable inline & onsite Stem - Stainless Steel, AISI-316, raised, replaceable inline & onsite Spring & Bearing bush- Stainless Steel, AISI-316 ,Disc guide, disc retainer & diaphragm washer - Stainless Steel, AISI-304/ 316/Bronze ,Seal- EPDM/ NBR ,Pilot Body- Stainless Steel, AISI-304/ CF8 or Brass Tubing - Stainless Steel, AISI-304 / Copper ,Solenoid Valve- Stainless Steel, AISI- 316 ,Throttling plug - Stainless Steel, AISI-304, Nut- Bolts - SS . Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. Insersion rubber of black EPDM 6mm thick Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.at Inlet CWR Diaphragm Type Flow Control Valve With Electrical Actuator suitable for scada (PN 1.6 ) |
| 57 | 100 mm |
| 58 | 150 mm |
| 59 | 200 mm |
| 60 | Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. Air valve pillarfor airvalves size upto 80mmdia |
| 61 | Upto 50 mm |
| 62 | 80 mm |
| 63 | Construction of village Transfer chambers (VTC) |
| 64 | Type A for Intermediate villages |
| 65 | Type B for endVillages |
| 66 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specificationscompleteof the followingsizesincludingall jointing material,costofalllabour,testingandcommissioning asper Technical Specifications and as per direction of Engineer.PN -1.6 |
| 67 | 80 mm |
| 68 | 100 mm |
| 69 | 125 mm |
| 70 | 150 mm |
| 71 | 200 mm |
| 72 | 250 mm |
| 73 | Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 74 | 80 mm HW |
| 75 | 100 mm HW |
| 76 | 125 mm HW |
| 77 | 150 mm HW |
| 78 | 200 mm HW |
| 79 | Carriage of Materials by mechanical transport including loading, unloading and stacking :: Sand Bedding |
| 80 | For Sand Bedding purpose in rocky Starta |
| 81 | Construction of RCC valve chamber for Valves different Size of Pipes including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & \"AA\" class LoadingFerro-Cement drain covers, including cost of steel reinforcement not less than 80kg per cum CC, form work,proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. For Sluice Valves |
| 82 | Upto 150 mm dia |
| 83 | 200 mm |
| 84 | 250 mm |
| 85 | Construction of RCC Flow Meter chamber |
| 86 | 100 mm |
| 87 | 150 mm |
| 88 | Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating . |
| 89 | 100mm dia- 5mm thk |
| 90 | 150mm dia- 5mm thk |
| 91 | 200mm dia- 5mm thk |
| 92 | 250mm dia- 5mm thk |
| 93 | Providing and making inner cement mortar lining to M.S. Pipes with mechanical devices in cement mortar 1:1 proportion , including cost of all materials, labour, special sand required, machinery, power generation, all equipments, including carrying out \"C\" value performance test of pipeline, including field joints at site complete as per technical specification and direction of Engineer in Incharge. |
| 94 | 100mm dia- 5mm thk |
| 95 | 150mm dia- 5mm thk |
| 96 | 200mm dia- 5mm thk |
| 97 | 250mm dia- 5mm thk |
| 98 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix |
| 99 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from ironores and roll the bilets to produce steel conforming to IS:1786)-Hot rolled deformed bars |
| 100 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 101 | SupplylayingandpushingofMScasingpipeofspecifiedthicknessapprovedby concerned department authority by trenchless method adopting any suitable technologybelowgroundatrequireddepthunderrunningtrafficconditionasper Highway/Railwaystandardincludingcarryingoutsurveyworkatthejobsitefor determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crewat thejob site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MScuttingedgesforfrontshieldandconstructingthrustbedatdesignatedlevel. Necessarydewateringandprovidingconcretefoundationatthebaseofthedriven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Applycorrosion,resistant,protectiononinsideandoutsideofcasingpipe asper technical specification. |
| 102 | Railway Crossing |
| 103 | Carrier Pipe 1505 No |
| 104 | Carrier Pipe 200 4 No |
| 105 | National & State Highway Crossing |
| 106 | Carrier Pipe 10033 No |
| 107 | 150 mm, 160 No |
| 108 | 200 mm, 78 No |
| 109 | 250 mm, 43 No |
| 110 | 300 mm, 2 No |
| 111 | Canal Crossing |
| 112 | Casing pipe 300 mm- 8mm thk- Carrier Pipe 10015 No |
| 113 | Casing pipe 300 mm- 8mm thk-Carrier Pipe 15016 No |
| 114 | Casing pipe 400 mm- 8mm thk- Carrier Pipe 20015 No |
| 115 | River / Nallah Crossing |
| 116 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: |
| 117 | Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
| 118 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like with pumping set of following H.P. including P.O.L. complete. 5 HP to 9 HP |
| 119 | Provision for Surge Protection |
| 120 | Providing, lowering, laying, alingning, fixing in position in pipe line Air Cussion Valvesas per IS:14845 of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer etc,complete in all respect |
| 121 | M.S. Fabricated Self Acting Air Cushion Valves suitable for pr. rating , PN-1.6 |
| 122 | 50 mm |
| 123 | 80 mm |
| 124 | 100 mm |
| 125 | 150 mm |
| 126 | Providing, lowering, laying, alingning, fixing in position in pipe line Zero Velocity Valves of as per IS:14845 of following dia (including jointing and jointing material), including all material,labour, testing and commissioning as per Technical Specifications and as per direction of Engineer etc,complete in all respect. |
| 127 | M.S. Fabricated Plain End Self actuating consists of Spring Loaded Closing Disc for stopping reverse flow Zero Velocity Valve with By-Pass arrangement |
| 128 | 100 mm |
| 129 | 150 mm |
| 130 | 200 mm |
| 131 | Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 132 | Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 133 | Bituminous courses |
| 134 | Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
| 135 | Providingandlayinginpositioncementconcreteinspecifiedgradeoverprepared basecoursecompleteincludingfinishing,curing,allmaterial,labour,machinery, lighting,guardingforroadrestorationworkintrenchesofpipelineandchamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
| 136 | M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 137 | Removing& Re-fixing of Precast concrete interlocking blocks for laying of pipe line by manual method, stacking of serviceable & non serviceable material separately, disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) |
| 138 | 80mm thick. |
| 139 | ProvidingHouseholdTapConnection aspertechnicalspecification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddlepiece(Completejob).Thisjobincludesdigging out suitable size of pits and trench for laying service line in all kinds of soil;depositingandrefillingofpit&jhiriwithwatering&ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting dulyapprovedinaccordancewith specificationforpotablewater including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-wayValve(IS:778Mark)orwheelvalveandspecials,below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008)(ISImark)forandabovegroundlevelusing20mm diaPPR-Cpipe withstandardPPRfittings/15mmdiaGIpipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing ofpipelinecompleterequiredformakingofserviceconnection completeinallrespectincludinglabourcharges.Theserviceline should be laid at least 45 cm below ground level.Note:Roadcutandrestorationisnotpartofthisitemandpaid seperately. |
| 140 | Forconnectionwith20mmdiaMDPE/PPR-Cpipelengthupto05 mtr. |
| 141 | P & F Bib cock (IS : 8931 mark), superior quality of approved make,chrome plated with complete brass body including brass handlewith wt. 300 to 325 gm.15 mm nominal bore. |
| 142 | Roadcuttingforhouseholdserviceconnectioninminimumtrench widthwhereeverroadcrossingisrequired.Roadcuttingofcement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. |
| 143 | Add extra over item no 1.21, 1.22 & 1.23 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. |
| 144 | Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers likei.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving license/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator. |
| 145 | Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coil including excavation, shoring/ strutting, preparation, maintain the thrust and including, road dismantling,excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work. Excluding cost of pipe line. Note: Trenchless laying shall be done only for laying of pipe line (rising main) and road crossing of distribution pipe line under CC/BT roads |
| 146 | Part-02: Construction of OHSR including boundary |
| 147 | ConstructionandcommissioningofRCCINTZEtypeOverHeadServiceReservoirof followingcapacityandstagingaspertheScopeofworkandTechnicalspecifications, consisting of the following main activities: -a)Topographicsurvey,preparationofsitecontourplan,conductingSBCtest andits approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c)OHSRshallbeprovidedwithadequateplinthprotectionallaroundthestructureina width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providingandapplyingthreecoatsofanti-carbonationpaintonthetopsurfaceof the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h)ProvidingandfixingSS-304ventilator,SS304manholeframeandcoverandSS-304 ladder from top dome/Slab to bottom dome/Slab inside container.i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type).k)Providingandfixingofhandrailingallaroundthebalcony,topdomeandstaircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamelpaint overthe primercoat of red oxide.m)Providingandfixingof150mmwidePVCwaterbarfortheconstructionjointsinthe container (vertical wall & cone wall).n) ProvidingoneAluminium portableladderofappropriatelengthto accessfirstlanding (3.5 to 4.5m above GL) from ground.o) Lighting arrestorconsisting ofproviding andfixing of2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work relatedtostructureasperthedirectionsofEngineer-in-Charge,TechnicalSpecification and Scope of Work.r)Inlet,outlet,overflow,washoutpipesandvalvesarenotincludedinthiswork, provision for the same shall be taken separately. |
| 148 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 22 M |
| 149 | 100 KL |
| 150 | 150 KL |
| 151 | 200 KL |
| 152 | 250 KL |
| 153 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 20 M |
| 154 | 100 KL |
| 155 | 150 KL |
| 156 | 200 KL |
| 157 | 350 KL |
| 158 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M |
| 159 | 100 KL |
| 160 | 150 KL |
| 161 | 200 KL |
| 162 | Construction and commissioning of RCC flat slab Over Head Service Reservoir offollowing capacity and staging including all material and labour charges as per the Scopeof work and Technical Specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and itsapproval from department before construction. Submission and approval of concrete mixdesign and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection allaround the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in awidth starting from edge of structure at GL and extending at least up to 1.0m beyond theedge of outer most projection of OHSR. The plinth protection shall consist of 150mm thickPCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roofslab, and 600 mm height of the vertical wall.e) Successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of theroof slab.g) Providing and applying three coats of cement-based paint on the external surface of thecontainer, balcony, cone wall, columns & beams etc.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladderwith safety cage from balcony to top slab. |
| 163 | j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, roof and staircase, consistingof 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle ironvertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat ofred oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in thecontainer (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing(3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing andconnecting it to the conical cover of SS ventilator with two separate GI strips of50mmX3mmp) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet,overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other workrelated to structure as per the directions of Engineer-in- Charge, Technical Specificationand Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work,provision for the same shall be taken separately. |
| 164 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M |
| 165 | 50 KL |
| 166 | 75 KL |
| 167 | ProvidingandfixingdoubleflangedISImarkedDI ClassK-9pipesasperIS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such asduckfootbend,bend,teeetc.providingandfixingclampsatevery3mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 168 | 100 mm |
| 169 | 150 mm |
| 170 | 200 mm |
| 171 | 250 mm |
| 172 | 300 mm |
| 173 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 174 | 100 mm |
| 175 | 150 mm |
| 176 | 200 mm |
| 177 | 250 mm |
| 178 | Construction of RCC valve chamber for Valves different Size of Pipes including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & \"AA\" class LoadingFerro-Cement drain covers, including cost of steel reinforcement not less than 80kg per cum CC, form work,proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. For Sluice Valves |
| 179 | upto 150 mm |
| 180 | 200 mm dia. |
| 181 | Providing, laying and fixing float valve system of following dia of C.I. with internal parts of auxiliary valve of copper float ball, gunmetal ball cap, brass lever, brass split pin, gunmetal piston & piston cap, washer of nitrile rubber with gunmetal body including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 182 | 100 MM |
| 183 | 150MM |
| 184 | Providing,lowering,laying,aligning, fixinginpositionandjointingCI dismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 |
| 185 | 100 mm |
| 186 | 150 mm |
| 187 | 200 mm |
| 188 | 250 mm |
| 189 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 190 | 80 OHSR @120m Each (30*30) |
| 191 | Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints. |
| 192 | Part-03:Construction of CWRs at Various Locations |
| 193 | Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - |
| 194 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
| 195 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 |
| 196 | Banda Kalan CWR |
| 197 | Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - |
| 198 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. .b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
| 199 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k)Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.Rates for RCC Partially Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC ZONE-2 & 3. |
| 200 | Khajurana Kalan |
| 201 | Aklera CWR |
| 202 | Kalanda CWR |
| 203 | Ranibarod CWR |
| 204 | Relawan CWR |
| 205 | Karwari Kalan CWR |
| 206 | Bajrang Garh CWR |
| 207 | Bhanwargarh CWR |
| 208 | Kasba Thana CWR |
| 209 | Kushyara CWR |
| 210 | Kaloni CWR |
| 211 | ProvidingandfixingdoubleflangedISImarkedDI ClassK-9pipesasperIS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such asduckfootbend,bend,teeetc.providingandfixingclampsatevery3mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 212 | 100 mm |
| 213 | 150 mm |
| 214 | 200 mm |
| 215 | 250 mm |
| 216 | 300 mm |
| 217 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 218 | 100 mm |
| 219 | 150 mm |
| 220 | 200 mm |
| 221 | 250mm |
| 222 | 300mm |
| 223 | Providing,lowering,laying,aligning, fixinginpositionandjointingCI dismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 |
| 224 | 100 mm |
| 225 | 150 mm |
| 226 | 200 mm |
| 227 | 250mm |
| 228 | 300mm |
| 229 | Construction of RCC valve chamber for Valves different Size of Pipes including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & \"AA\" class LoadingFerro-Cement drain covers, including cost of steel reinforcement not less than 80kg per cum CC, form work,proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. For Sluice Valves |
| 230 | 1. Inlet, 2.out let 3.Washout & Overflow Chamber |
| 231 | Part-04: A- Construction ofPump house at Khushyara |
| 232 | Civil work such as construction of pump House. |
| 233 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. AtKUSHYARA Head worknear proposed 950 KL CWR (For Installation of 4W+4S Pumps & 2 pumps for future ) |
| 234 | Mechanical Equipment & Accessories |
| 235 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 236 | Route 1-26.86 LPS / 75 m head/40 KW |
| 237 | Route 2-19.64 LPS /65 m head/25 KW |
| 238 | Route 3-15.99 LPS / 115 m head/35 KW |
| 239 | Route 4-20.95 LPS / 20 m head/10 KW |
| 240 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 241 | 125mm dia- 5mm thk |
| 242 | 150mm dia- 5mm thk |
| 243 | 200mm dia- 5mm thk |
| 244 | 300mm dia- 6mm thk |
| 245 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 246 | 125mm dia- 5mm thk |
| 247 | 150mm dia- 5mm thk |
| 248 | 200mm dia- 5mm thk |
| 249 | 300mm dia- 6mm thk |
| 250 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 251 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 252 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 253 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 254 | 125 mm dia |
| 255 | 150 mm dia |
| 256 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 257 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 258 | 125 mm dia |
| 259 | 150 mm dia |
| 260 | 200 mm dia |
| 261 | 300 mm dia |
| 262 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 263 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 264 | 125 mm dia |
| 265 | 150 mm dia |
| 266 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 267 | 125 mm dia |
| 268 | 150 mm dia |
| 269 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 270 | 125 mm dia |
| 271 | 150 mm dia |
| 272 | 200 mm dia |
| 273 | 300 mm dia |
| 274 | Electric Overhead Travelling (EOT) Crane |
| 275 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 276 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 277 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 278 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 279 | 50 mm |
| 280 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 281 | - 1.0 to +1.0 kg/cm² |
| 282 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 283 | EFM 125 mm |
| 284 | EFM 150 mm |
| 285 | Water meter chamber: |
| 286 | 125MM |
| 287 | 150 MM |
| 288 | Electric equipment and accessories |
| 289 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 290 | 250KVA |
| 291 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 292 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 293 | 110VDC |
| 294 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 295 | 25 A + 25 A |
| 296 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 297 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 298 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 299 | 50mm x 6mm copper strip |
| 300 | 50mm x 6mm G.I. Strip |
| 301 | 32mm x6mm G.I. Strip |
| 302 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 303 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 304 | 3 core 120.0 Sq.mm |
| 305 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 306 | Indoor |
| 307 | 3 core 120/150/185 Sq.mm |
| 308 | Outdoor |
| 309 | 3 core 120/150/185/225 Sq.mm |
| 310 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 311 | 185 SQMM,3.5 CORE |
| 312 | 50 SQMM, 3 CORE |
| 313 | 35 SQMM, 3 CORE |
| 314 | 16 SQMM, 3 CORE |
| 315 | 4.0 Sq.mm x 3 Core |
| 316 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 317 | Hot Dipped Galvanized |
| 318 | 450mm x 50mm x 2.0mm |
| 319 | 600mm x 50mm x 2.0mm |
| 320 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 321 | Hot Dipped Galvanized |
| 322 | 100mm x 50mm x 1.6mm |
| 323 | 150mm x 50mm x 1.6mm |
| 324 | 300mm x 50mm x 1.6mm |
| 325 | 450mm x 50mm x 2.0mm |
| 326 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 327 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 328 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 329 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 330 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 331 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 332 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 333 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 334 | 250AMCCB(Fixedtype)asoutgoingCT\"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D) |
| 335 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 336 | 30KW |
| 337 | 37KW |
| 338 | 45KW |
| 339 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowingrating |
| 340 | 11KW |
| 341 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 342 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 343 | Local Push Button Station |
| 344 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 345 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 346 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 347 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 348 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 349 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 350 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 351 | Chlorinators 1 kg/Hr Capacity) |
| 352 | Chlorine Tonner 900 Kg |
| 353 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 354 | Chlorinator Room |
| 355 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 356 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 357 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 358 | 1.5 KW (2.0 HP) |
| 359 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 360 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 361 | Part-04: B- Construction ofPump house at KASBA THANA PH |
| 362 | Civil work such as construction of pump House. |
| 363 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.AtKASBA THANA Head worknear proposed 1200 KL CWR (For Installation of 3W+3S Pumps & 2 pumps for future ) |
| 364 | Mechanical Equipment & Accessories |
| 365 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 366 | Route 1-14.36 LPS / 65 m head/20 KW |
| 367 | Route 2-22.05 LPS /80 m head/35 KW |
| 368 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 369 | 125mm dia- 5mm thk |
| 370 | 150mm dia- 5mm thk |
| 371 | 200mm dia- 5mm thk |
| 372 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 373 | 125mm dia- 5mm thk |
| 374 | 150mm dia- 5mm thk |
| 375 | 200mm dia- 5mm thk |
| 376 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 377 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 378 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 379 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 380 | 125 mm dia |
| 381 | 150 mm dia |
| 382 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 383 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 384 | 125 mm dia |
| 385 | 150 mm dia |
| 386 | 200 mm dia |
| 387 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 388 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 389 | 125 mm dia |
| 390 | 150 mm dia |
| 391 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 392 | 125 mm dia |
| 393 | 150 mm dia |
| 394 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 395 | 125 mm dia |
| 396 | 150 mm dia |
| 397 | 200 mm dia |
| 398 | Electric Overhead Travelling (EOT) Crane |
| 399 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 400 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 401 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 402 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 403 | 50 mm |
| 404 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 405 | - 1.0 to +1.0 kg/cm² |
| 406 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 407 | EFM125 mm |
| 408 | EFM 150 mm |
| 409 | Water meter chamber: |
| 410 | Chamber |
| 411 | Electric equipment and accessories |
| 412 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 413 | 160KVA |
| 414 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 415 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 416 | 110VDC |
| 417 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 418 | 25 A + 25 A |
| 419 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 420 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 421 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 422 | 50mm x 6mm copper strip |
| 423 | 50mm x 6mm G.I. Strip |
| 424 | 32mm x6mm G.I. Strip |
| 425 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 426 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 427 | 3 core 120.0 Sq.mm |
| 428 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 429 | Indoor |
| 430 | 3 core 120/150/185 Sq.mm |
| 431 | Outdoor |
| 432 | 3 core 120/150/185/225 Sq.mm |
| 433 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 434 | 120 SQMM,3.5 CORE |
| 435 | 35 SQMM, 3 CORE |
| 436 | 25 SQMM, 3 CORE |
| 437 | 4.0 Sq.mm x 3 Core |
| 438 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 439 | Hot Dipped Galvanized |
| 440 | 450mm x 50mm x 2.0mm |
| 441 | 600mm x 50mm x 2.0mm |
| 442 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 443 | Hot Dipped Galvanized |
| 444 | 100mm x 50mm x 1.6mm |
| 445 | 150mm x 50mm x 1.6mm |
| 446 | 300mm x 50mm x 1.6mm |
| 447 | 450mm x 50mm x 2.0mm |
| 448 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 449 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 450 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 451 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 452 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 453 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 454 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 455 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 456 | 125 A MCCB (Fixed type )as outgoing CT\"s, Ampermeter with SS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)600(H)X1000(D) |
| 457 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 458 | 37KW |
| 459 | 22KW |
| 460 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 461 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 462 | Local Push Button Station |
| 463 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 464 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 465 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 466 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 467 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 468 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 469 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 470 | Chlorinators 1 kg/Hr Capacity) |
| 471 | Chlorine Tonner 900 Kg |
| 472 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 473 | Chlorinator Room |
| 474 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 475 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 476 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 477 | 1.5 KW (2.0 HP) |
| 478 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 479 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 480 | Part-04: C- Construction ofPump house at Kaloni |
| 481 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.AtKALONI Head worknear proposed 1600 KL CWR (For Installation of 3W+3S Pumps & 2 pumps for future ) |
| 482 | Mechanical Equipment & Accessories |
| 483 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 484 | Route 1-22.97 LPS / 70 m head/30 KW |
| 485 | Route 2-16.39 LPS /70 m head/25 KW |
| 486 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 487 | 125mm dia- 5mm thk |
| 488 | 150mm dia- 5mm thk |
| 489 | 200mm dia- 5mm thk |
| 490 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 491 | 125mm dia- 5mm thk |
| 492 | 150mm dia- 5mm thk |
| 493 | 200mm dia- 5mm thk |
| 494 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 495 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 496 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 497 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 498 | 125 mm dia |
| 499 | 150 mm dia |
| 500 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 501 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 502 | 125 mm dia |
| 503 | 150 mm dia |
| 504 | 200 mm dia |
| 505 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 506 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 507 | 125 mm dia |
| 508 | 150 mm dia |
| 509 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 510 | 125 mm dia |
| 511 | 150 mm dia |
| 512 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 513 | 125 mm dia |
| 514 | 150 mm dia |
| 515 | 200 mm dia |
| 516 | Electric Overhead Travelling (EOT) Crane |
| 517 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 518 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 519 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 520 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 521 | 50 mm |
| 522 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 523 | - 1.0 to +1.0 kg/cm² |
| 524 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 525 | EFM125 mm |
| 526 | EFM 150 mm |
| 527 | Water meter chamber: |
| 528 | Chamber |
| 529 | Electric equipment and accessories |
| 530 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 531 | 160KVA |
| 532 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 533 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 534 | 110VDC |
| 535 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 536 | 25 A + 25 A |
| 537 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 538 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 539 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 540 | 50mm x 6mm copper strip |
| 541 | 50mm x 6mm G.I. Strip |
| 542 | 32mm x6mm G.I. Strip |
| 543 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 544 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 545 | 3 core 120.0 Sq.mm |
| 546 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 547 | Indoor |
| 548 | 3 core 120/150/185 Sq.mm |
| 549 | Outdoor |
| 550 | 3 core 120/150/185/225 Sq.mm |
| 551 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 552 | 120 SQMM,3.5 CORE |
| 553 | 35 SQMM, 3 CORE |
| 554 | 4.0 Sq.mm x 3 Core |
| 555 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 556 | Hot Dipped Galvanized |
| 557 | 450mm x 50mm x 2.0mm |
| 558 | 600mm x 50mm x 2.0mm |
| 559 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 560 | Hot Dipped Galvanized |
| 561 | 100mm x 50mm x 1.6mm |
| 562 | 150mm x 50mm x 1.6mm |
| 563 | 300mm x 50mm x 1.6mm |
| 564 | 450mm x 50mm x 2.0mm |
| 565 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 566 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 567 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 568 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 569 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 570 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 571 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 572 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 573 | 125 A MCCB (Fixed type )as outgoing CT\"s, Ampermeter with SS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)600(H)X1000(D) |
| 574 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 575 | 30KW |
| 576 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 577 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 578 | Local Push Button Station |
| 579 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 580 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 581 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 582 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 583 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 584 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 585 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 586 | Chlorinators 1 kg/Hr Capacity) |
| 587 | Chlorine Tonner 900 Kg |
| 588 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 589 | Chlorinator Room |
| 590 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 591 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 592 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 593 | 1.5 KW (2.0 HP) |
| 594 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 595 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 596 | Part-05: C- Construction ofPump house at Ranibarod |
| 597 | Civil work such as construction of pump House. |
| 598 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At KUSHALPURA Head worknear proposed 1300 KL CWR (For Installation of 1W+1S Pumps & 2 pumps for future ) |
| 599 | Mechanical Equipment & Accessories |
| 600 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 601 | Route 1-23.11 LPS / 60 m head/25 KW |
| 602 | Route 2-19.70 LPS /70 m head/25 KW |
| 603 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 604 | 125mm dia- 5mm thk |
| 605 | 150mm dia- 5mm thk |
| 606 | 200mm dia- 5mm thk |
| 607 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 608 | 125mm dia- 5mm thk |
| 609 | 150mm dia- 5mm thk |
| 610 | 200mm dia- 5mm thk |
| 611 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 612 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 613 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 614 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 615 | 125 mm dia |
| 616 | 150 mm dia |
| 617 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 618 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 619 | 125 mm dia |
| 620 | 150 mm dia |
| 621 | 200 mm dia |
| 622 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 623 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 624 | 125 mm dia |
| 625 | 150 mm dia |
| 626 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 627 | 125 mm dia |
| 628 | 150 mm dia |
| 629 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 630 | 125 mm dia |
| 631 | 150 mm dia |
| 632 | 200 mm dia |
| 633 | Electric Overhead Travelling (EOT) Crane |
| 634 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 635 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 636 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 637 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 638 | 50 mm |
| 639 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 640 | - 1.0 to +1.0 kg/cm² |
| 641 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 642 | EFM125 mm |
| 643 | EFM 150 mm |
| 644 | Water meter chamber: |
| 645 | Chamber |
| 646 | Electric equipment and accessories |
| 647 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 648 | 160KVA |
| 649 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 650 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 651 | 110VDC |
| 652 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 653 | 25 A + 25 A |
| 654 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 655 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 656 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 657 | 50mm x 6mm copper strip |
| 658 | 50mm x 6mm G.I. Strip |
| 659 | 32mm x6mm G.I. Strip |
| 660 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 661 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 662 | 3 core 120.0 Sq.mm |
| 663 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 664 | Indoor |
| 665 | 3 core 120/150/185 Sq.mm |
| 666 | Outdoor |
| 667 | 3 core 120/150/185/225 Sq.mm |
| 668 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 669 | 120 SQMM,3.5 CORE |
| 670 | 35 SQMM, 3 CORE |
| 671 | 4.0 Sq.mm x 3 Core |
| 672 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 673 | Hot Dipped Galvanized |
| 674 | 450mm x 50mm x 2.0mm |
| 675 | 600mm x 50mm x 2.0mm |
| 676 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 677 | Hot Dipped Galvanized |
| 678 | 100mm x 50mm x 1.6mm |
| 679 | 150mm x 50mm x 1.6mm |
| 680 | 300mm x 50mm x 1.6mm |
| 681 | 450mm x 50mm x 2.0mm |
| 682 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 683 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 684 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 685 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 686 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 687 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 688 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 689 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 690 | 125 A MCCB (Fixed type )as outgoing CT\"s, Ampermeter with SS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)600(H)X1000(D) |
| 691 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 692 | 30KW |
| 693 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 694 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 695 | Local Push Button Station |
| 696 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 697 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 698 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 699 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 700 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 701 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 702 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 703 | Chlorinators 1 kg/Hr Capacity) |
| 704 | Chlorine Tonner 900 Kg |
| 705 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 706 | Chlorinator Room |
| 707 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 708 | 1.5 KW (2.0 HP) |
| 709 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 710 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 711 | Part-04: C- Construction ofPump house at BANDA KALAN PH |
| 712 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At BANDA KALAN Head worknear proposed 1000 KL CWR (For Installation of 1W+1S Pumps & 2 pumps for future ) |
| 713 | Mechanical Equipment & Accessories |
| 714 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 715 | Balapura route27.33 LPS /25 m head/15 KW |
| 716 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 717 | 100mm dia- 5mm thk |
| 718 | 125mm dia- 5mm thk |
| 719 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 720 | 100mm dia- 5mm thk |
| 721 | 125mm dia- 5mm thk |
| 722 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 723 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 724 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 725 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 726 | 125 mm dia |
| 727 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 728 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 729 | 100 mm dia |
| 730 | 125 mm dia |
| 731 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 732 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 733 | 125 mm dia |
| 734 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 735 | 125 mm dia |
| 736 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 737 | 100 mm dia |
| 738 | 125 mm dia |
| 739 | Electric Overhead Travelling (EOT) Crane |
| 740 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 741 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 742 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 743 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 744 | 50 mm |
| 745 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 746 | - 1.0 to +1.0 kg/cm² |
| 747 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 748 | EFM 100 mm |
| 749 | Water meter chamber: |
| 750 | Chamber |
| 751 | Electric equipment and accessories |
| 752 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 753 | 100KVA |
| 754 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 755 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 756 | 110VDC |
| 757 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 758 | 25 A + 25 A |
| 759 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 760 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 761 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 762 | 50mm x 6mm copper strip |
| 763 | 50mm x 6mm G.I. Strip |
| 764 | 32mm x6mm G.I. Strip |
| 765 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 766 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 767 | 3 core 120.0 Sq.mm |
| 768 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 769 | Indoor |
| 770 | 3 core 120/150/185 Sq.mm |
| 771 | Outdoor |
| 772 | 3 core 120/150/185/225 Sq.mm |
| 773 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 774 | 70 SQMM,3.5 CORE |
| 775 | 16 SQMM, 3 CORE |
| 776 | 4.0 Sq.mm x 3 Core |
| 777 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 778 | Hot Dipped Galvanized |
| 779 | 450mm x 50mm x 2.0mm |
| 780 | 600mm x 50mm x 2.0mm |
| 781 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 782 | Hot Dipped Galvanized |
| 783 | 100mm x 50mm x 1.6mm |
| 784 | 150mm x 50mm x 1.6mm |
| 785 | 300mm x 50mm x 1.6mm |
| 786 | 450mm x 50mm x 2.0mm |
| 787 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 788 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 789 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 790 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 791 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 792 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 793 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 794 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 795 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 796 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowingrating |
| 797 | 15KW |
| 798 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 799 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 800 | Local Push Button Station |
| 801 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 802 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 803 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 804 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 805 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 806 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 807 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 808 | Chlorinators 1 kg/Hr Capacity) |
| 809 | Chlorine Tonner 900 Kg |
| 810 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 811 | Chlorinator Room |
| 812 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 813 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 814 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 815 | 1.5 KW (2.0 HP) |
| 816 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 817 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 818 | Part-04: C- Construction ofPump house at BAJRANG GARH PH |
| 819 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At BAJRANG GARH Head worknear proposed 1900 KL CWR (For Installation of 3W+3S Pumps & 2 pumps for future ) |
| 820 | Mechanical Equipment & Accessories |
| 821 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 822 | Route 1-23.42 LPS / 80 m head/35 KW |
| 823 | Route 2-12.95 LPS /60 m head/15 KW |
| 824 | Route 3-23.02 LPS / 80 m head/35 KW |
| 825 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 826 | 100mm dia- 5mm thk |
| 827 | 125mm dia- 5mm thk |
| 828 | 150mm dia- 5mm thk |
| 829 | 250mm dia- 5mm thk |
| 830 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 831 | 100mm dia- 5mm thk |
| 832 | 125mm dia- 5mm thk |
| 833 | 150mm dia- 5mm thk |
| 834 | 250mm dia- 5mm thk |
| 835 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 836 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 837 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 838 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 839 | 100 mm dia |
| 840 | 150 mm dia |
| 841 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 842 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 843 | 100 mm dia |
| 844 | 125 mm dia |
| 845 | 150 mm dia |
| 846 | 250 mm dia |
| 847 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 848 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 849 | 100 mm dia |
| 850 | 150 mm dia |
| 851 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 852 | 100 mm dia |
| 853 | 150 mm dia |
| 854 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 855 | 100 mm dia |
| 856 | 125 mm dia |
| 857 | 150 mm dia |
| 858 | 250 mm dia |
| 859 | Electric Overhead Travelling (EOT) Crane |
| 860 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 861 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 862 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 863 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 864 | 50 mm |
| 865 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 866 | - 1.0 to +1.0 kg/cm² |
| 867 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 868 | EFM 100 mm |
| 869 | EFM 150 mm |
| 870 | Water meter chamber: |
| 871 | Chamber |
| 872 | Electric equipment and accessories |
| 873 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 874 | 200KVA |
| 875 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 876 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 877 | 110VDC |
| 878 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 879 | 25 A + 25 A |
| 880 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 881 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 882 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 883 | 50mm x 6mm copper strip |
| 884 | 50mm x 6mm G.I. Strip |
| 885 | 32mm x6mm G.I. Strip |
| 886 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 887 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 888 | 3 core 120.0 Sq.mm |
| 889 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 890 | Indoor |
| 891 | 3 core 120/150/185 Sq.mm |
| 892 | Outdoor |
| 893 | 3 core 120/150/185/225 Sq.mm |
| 894 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 895 | 185 SQMM,3.5 CORE |
| 896 | 35 SQMM, 3 CORE |
| 897 | 16 SQMM, 3 CORE |
| 898 | 4.0 Sq.mm x 3 Core |
| 899 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 900 | Hot Dipped Galvanized |
| 901 | 450mm x 50mm x 2.0mm |
| 902 | 600mm x 50mm x 2.0mm |
| 903 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 904 | Hot Dipped Galvanized |
| 905 | 100mm x 50mm x 1.6mm |
| 906 | 150mm x 50mm x 1.6mm |
| 907 | 300mm x 50mm x 1.6mm |
| 908 | 450mm x 50mm x 2.0mm |
| 909 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 910 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 911 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 912 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 913 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 914 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 915 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 916 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 917 | 250AMCCB(Fixedtype)asoutgoingCT\"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D) |
| 918 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 919 | 37KW |
| 920 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowingrating |
| 921 | 15KW |
| 922 | 433V APFC Panel( 50KVAR) in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 923 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 924 | Local Push Button Station |
| 925 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 926 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 927 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 928 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 929 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 930 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 931 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 932 | Chlorinators 1 kg/Hr Capacity) |
| 933 | Chlorine Tonner 900 Kg |
| 934 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 935 | Chlorinator Room |
| 936 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 937 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 938 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 939 | 1.5 KW (2.0 HP) |
| 940 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 941 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 942 | Part-04: C- Construction ofPump house at BHANWAR GARH PH |
| 943 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At BHANWAR GARH Head worknear proposed 1500 KL CWR (For Installation of 2W+2S Pumps & 2 pumps for future ) |
| 944 | Mechanical Equipment & Accessories |
| 945 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 946 | Route 1-24.06 LPS / 105 m head/45 KW |
| 947 | Route 2-28.42 LPS /95 m head/50 KW |
| 948 | Route 3-12 LPS / 75 m head/20 KW |
| 949 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 950 | 100mm dia- 5mm thk |
| 951 | 125mm dia- 5mm thk |
| 952 | 150mm dia- 5mm thk |
| 953 | 200mm dia- 5mm thk |
| 954 | 250mm dia- 5mm thk |
| 955 | 300mm dia- 6mm thk |
| 956 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 957 | 100mm dia- 5mm thk |
| 958 | 125mm dia- 5mm thk |
| 959 | 150mm dia- 5mm thk |
| 960 | 200mm dia- 5mm thk |
| 961 | 250mm dia- 5mm thk |
| 962 | 300mm dia- 6mm thk |
| 963 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 964 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 965 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 966 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 967 | 100 mm dia |
| 968 | 150 mm dia |
| 969 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 970 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 971 | 100 mm dia |
| 972 | 125 mm dia |
| 973 | 150 mm dia |
| 974 | 200 mm dia |
| 975 | 250 mm dia |
| 976 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 977 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 978 | 100 mm dia |
| 979 | 150 mm dia |
| 980 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 981 | 100 mm dia |
| 982 | 150 mm dia |
| 983 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 984 | 100 mm dia |
| 985 | 125 mm dia |
| 986 | 150 mm dia |
| 987 | 200 mm dia |
| 988 | 250 mm dia |
| 989 | Electric Overhead Travelling (EOT) Crane |
| 990 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 991 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 992 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 993 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 994 | 50 mm |
| 995 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 996 | - 1.0 to +1.0 kg/cm² |
| 997 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 998 | EFM 100 mm |
| 999 | EFM 150 mm |
| 1000 | Water meter chamber: |
| 1001 | Chamber |
| 1002 | Electric equipment and accessories |
| 1003 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 1004 | 250KVA |
| 1005 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 1006 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 1007 | 110VDC |
| 1008 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 1009 | 25 A + 25 A |
| 1010 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1011 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1012 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 1013 | 50mm x 6mm copper strip |
| 1014 | 50mm x 6mm G.I. Strip |
| 1015 | 32mm x6mm G.I. Strip |
| 1016 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 1017 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 1018 | 3 core 120.0 Sq.mm |
| 1019 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 1020 | Indoor |
| 1021 | 3 core 120/150/185 Sq.mm |
| 1022 | Outdoor |
| 1023 | 3 core 120/150/185/225 Sq.mm |
| 1024 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 1025 | 185 SQMM,3.5 CORE |
| 1026 | 70 SQMM, 3 CORE |
| 1027 | 50 SQMM, 3 CORE |
| 1028 | 35 SQMM, 3 CORE |
| 1029 | 4.0 Sq.mm x 3 Core |
| 1030 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 1031 | Hot Dipped Galvanized |
| 1032 | 450mm x 50mm x 2.0mm |
| 1033 | 600mm x 50mm x 2.0mm |
| 1034 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 1035 | Hot Dipped Galvanized |
| 1036 | 100mm x 50mm x 1.6mm |
| 1037 | 150mm x 50mm x 1.6mm |
| 1038 | 300mm x 50mm x 1.6mm |
| 1039 | 450mm x 50mm x 2.0mm |
| 1040 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 1041 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 1042 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1043 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1044 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1045 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1046 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1047 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1048 | 250AMCCB(Fixedtype)asoutgoingCT\"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D) |
| 1049 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 1050 | 22KW |
| 1051 | 45KW |
| 1052 | 55KW |
| 1053 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 1054 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 1055 | Local Push Button Station |
| 1056 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 1057 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 1058 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 1059 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 1060 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 1061 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 1062 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 1063 | Chlorinators 1 kg/Hr Capacity) |
| 1064 | Chlorine Tonner 900 Kg |
| 1065 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 1066 | Chlorinator Room |
| 1067 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 1068 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 1069 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 1070 | 1.5 KW (2.0 HP) |
| 1071 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 1072 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 1073 | Part-04: C- Construction ofPump house at RELAWAN PH |
| 1074 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At RELAWAN Head worknear proposed 1900 KL CWR (For Installation of 3W+3S Pumps & 2 pumps for future ) |
| 1075 | Mechanical Equipment & Accessories |
| 1076 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 1077 | Route 1-16.11 LPS / 60 m head/20 KW |
| 1078 | Route 2-13.23 LPS /60 m head/15 KW |
| 1079 | Route 3- 19.48 LPS / 60 m head/25 KW |
| 1080 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 1081 | 100mm dia- 5mm thk |
| 1082 | 125mm dia- 5mm thk |
| 1083 | 150mm dia- 5mm thk |
| 1084 | 250mm dia- 5mm thk |
| 1085 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 1086 | 100mm dia- 5mm thk |
| 1087 | 125mm dia- 5mm thk |
| 1088 | 150mm dia- 5mm thk |
| 1089 | 250mm dia- 5mm thk |
| 1090 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 1091 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 1092 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1093 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 1094 | 100 mm dia |
| 1095 | 125 mm dia |
| 1096 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1097 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 1098 | 100 mm dia |
| 1099 | 125 mm dia |
| 1100 | 150 mm dia |
| 1101 | 250 mm dia |
| 1102 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1103 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 1104 | 100 mm dia |
| 1105 | 125 mm dia |
| 1106 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1107 | 100 mm dia |
| 1108 | 125 mm dia |
| 1109 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 1110 | 100 mm dia |
| 1111 | 125 mm dia |
| 1112 | 150 mm dia |
| 1113 | 250 mm dia |
| 1114 | Electric Overhead Travelling (EOT) Crane |
| 1115 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 1116 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 1117 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 1118 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 1119 | 50 mm |
| 1120 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 1121 | - 1.0 to +1.0 kg/cm² |
| 1122 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 1123 | EFM100 mm |
| 1124 | EFM 125 mm |
| 1125 | Water meter chamber: |
| 1126 | Chamber |
| 1127 | Electric equipment and accessories |
| 1128 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 1129 | 160KVA |
| 1130 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 1131 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 1132 | 110VDC |
| 1133 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 1134 | 25 A + 25 A |
| 1135 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1136 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1137 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 1138 | 50mm x 6mm copper strip |
| 1139 | 50mm x 6mm G.I. Strip |
| 1140 | 32mm x6mm G.I. Strip |
| 1141 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 1142 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 1143 | 3 core 120.0 Sq.mm |
| 1144 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 1145 | Indoor |
| 1146 | 3 core 120/150/185 Sq.mm |
| 1147 | Outdoor |
| 1148 | 3 core 120/150/185/225 Sq.mm |
| 1149 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 1150 | 120 SQMM,3.5 CORE |
| 1151 | 35 SQMM, 3 CORE |
| 1152 | 16 SQMM, 3 CORE |
| 1153 | 25 SQMM, 3 CORE |
| 1154 | 4.0 Sq.mm x 3 Core |
| 1155 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 1156 | Hot Dipped Galvanized |
| 1157 | 450mm x 50mm x 2.0mm |
| 1158 | 600mm x 50mm x 2.0mm |
| 1159 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 1160 | Hot Dipped Galvanized |
| 1161 | 100mm x 50mm x 1.6mm |
| 1162 | 150mm x 50mm x 1.6mm |
| 1163 | 300mm x 50mm x 1.6mm |
| 1164 | 450mm x 50mm x 2.0mm |
| 1165 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 1166 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 1167 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1168 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1169 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1170 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1171 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1172 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1173 | 125 A MCCB (Fixed type )as outgoing CT\"s, Ampermeter with SS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)600(H)X1000(D) |
| 1174 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 1175 | 22KW |
| 1176 | 30KW |
| 1177 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowingrating |
| 1178 | 15KW |
| 1179 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 1180 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 1181 | Local Push Button Station |
| 1182 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 1183 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 1184 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 1185 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 1186 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 1187 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 1188 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 1189 | Chlorinators 1 kg/Hr Capacity) |
| 1190 | Chlorine Tonner 900 Kg |
| 1191 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 1192 | Chlorinator Room |
| 1193 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 1194 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 1195 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 1196 | 1.5 KW (2.0 HP) |
| 1197 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 1198 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 1199 | Part-04: C- Construction ofPump house at KARWARI KALAN PH |
| 1200 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At KARWARI KALAN Head worknear proposed 950 KL CWR (For Installation of 2W+2S Pumps & 2 pumps for future ) |
| 1201 | Mechanical Equipment & Accessories |
| 1202 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 1203 | Route 1-16.15 LPS / 80 m head/25 KW |
| 1204 | Route 2-17.26 LPS /85 m head/30 KW |
| 1205 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 1206 | 125mm dia- 5mm thk |
| 1207 | 150mm dia- 5mm thk |
| 1208 | 200mm dia- 5mm thk |
| 1209 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 1210 | 125mm dia- 5mm thk |
| 1211 | 150mm dia- 5mm thk |
| 1212 | 200mm dia- 5mm thk |
| 1213 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 1214 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 1215 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1216 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 1217 | 125 mm dia |
| 1218 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1219 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 1220 | 125 mm dia |
| 1221 | 150 mm dia |
| 1222 | 200 mm dia |
| 1223 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1224 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 1225 | 125 mm dia |
| 1226 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1227 | 125 mm dia |
| 1228 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 1229 | 125 mm dia |
| 1230 | 150 mm dia |
| 1231 | 200 mm dia |
| 1232 | Electric Overhead Travelling (EOT) Crane |
| 1233 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 1234 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 1235 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 1236 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 1237 | 50 mm |
| 1238 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 1239 | - 1.0 to +1.0 kg/cm² |
| 1240 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 1241 | EFM 125 mm |
| 1242 | Water meter chamber: |
| 1243 | Chamber |
| 1244 | Electric equipment and accessories |
| 1245 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 1246 | 160KVA |
| 1247 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 1248 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 1249 | 110VDC |
| 1250 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 1251 | 25 A + 25 A |
| 1252 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1253 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1254 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 1255 | 50mm x 6mm copper strip |
| 1256 | 50mm x 6mm G.I. Strip |
| 1257 | 32mm x6mm G.I. Strip |
| 1258 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 1259 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 1260 | 3 core 120.0 Sq.mm |
| 1261 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 1262 | Indoor |
| 1263 | 3 core 120/150/185 Sq.mm |
| 1264 | Outdoor |
| 1265 | 3 core 120/150/185/225 Sq.mm |
| 1266 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 1267 | 120 SQMM,3.5 CORE |
| 1268 | 35 SQMM, 3 CORE |
| 1269 | 4.0 Sq.mm x 3 Core |
| 1270 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 1271 | Hot Dipped Galvanized |
| 1272 | 450mm x 50mm x 2.0mm |
| 1273 | 600mm x 50mm x 2.0mm |
| 1274 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 1275 | Hot Dipped Galvanized |
| 1276 | 100mm x 50mm x 1.6mm |
| 1277 | 150mm x 50mm x 1.6mm |
| 1278 | 300mm x 50mm x 1.6mm |
| 1279 | 450mm x 50mm x 2.0mm |
| 1280 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 1281 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 1282 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1283 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1284 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1285 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1286 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1287 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1288 | 125 A MCCB (Fixed type )as outgoing CT\"s, Ampermeter with SS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)600(H)X1000(D) |
| 1289 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 1290 | 30KW |
| 1291 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 1292 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 1293 | Local Push Button Station |
| 1294 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 1295 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 1296 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 1297 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 1298 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 1299 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 1300 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 1301 | Chlorinators 1 kg/Hr Capacity) |
| 1302 | Chlorine Tonner 900 Kg |
| 1303 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 1304 | Chlorinator Room |
| 1305 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 1306 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 1307 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 1308 | 1.5 KW (2.0 HP) |
| 1309 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 1310 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 1311 | Part-04: C- Construction ofPump house at Khajurana Kalan PH |
| 1312 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At Khajrana Kalan Head worknear proposed 1300 KL CWR (For Installation of 4W+4S Pumps ) |
| 1313 | Mechanical Equipment & Accessories |
| 1314 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 1315 | Route 1-10.10 LPS / 50 m head/10 KW |
| 1316 | Route 2-17.92 LPS /60 m head/20 KW |
| 1317 | Route 3-5 LPS / 55 m head/10 KW |
| 1318 | Route 4-6.27 LPS /50 m head/10 KW |
| 1319 | Route 5-8.84 LPS /65 m head/15 KW |
| 1320 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 1321 | 100mm dia- 5mm thk |
| 1322 | 125mm dia- 5mm thk |
| 1323 | 150mm dia- 5mm thk |
| 1324 | 250mm dia- 5mm thk |
| 1325 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 1326 | 100mm dia- 5mm thk |
| 1327 | 125mm dia- 5mm thk |
| 1328 | 150mm dia- 5mm thk |
| 1329 | 250mm dia- 5mm thk |
| 1330 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 1331 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 1332 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1333 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 1334 | 100 mm dia |
| 1335 | 125 mm dia |
| 1336 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1337 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 1338 | 100 mm dia |
| 1339 | 125 mm dia |
| 1340 | 150 mm dia |
| 1341 | 250 mm dia |
| 1342 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1343 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 1344 | 100 mm dia |
| 1345 | 125 mm dia |
| 1346 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1347 | 100 mm dia |
| 1348 | 125 mm dia |
| 1349 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 1350 | 100 mm dia |
| 1351 | 125 mm dia |
| 1352 | 150 mm dia |
| 1353 | 250 mm dia |
| 1354 | Electric Overhead Travelling (EOT) Crane |
| 1355 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 1356 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 1357 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 1358 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 1359 | 50 mm dia. |
| 1360 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 1361 | - 1.0 to +1.0 kg/cm² |
| 1362 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 1363 | EFM100 mm |
| 1364 | EFM 125 mm |
| 1365 | Water meter chamber: |
| 1366 | Chamber |
| 1367 | Electric equipment and accessories |
| 1368 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 1369 | 160KVA |
| 1370 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 1371 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 1372 | 110VDC |
| 1373 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 1374 | 25 A + 25 A |
| 1375 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1376 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1377 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 1378 | 50mm x 6mm copper strip |
| 1379 | 50mm x 6mm G.I. Strip |
| 1380 | 32mm x6mm G.I. Strip |
| 1381 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 1382 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 1383 | 3 core 120.0 Sq.mm |
| 1384 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 1385 | Indoor |
| 1386 | 3 core 120/150/185 Sq.mm |
| 1387 | Outdoor |
| 1388 | 3 core 120/150/185/225 Sq.mm |
| 1389 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 1390 | 120 SQMM,3.5 CORE |
| 1391 | 16 SQMM, 3 CORE |
| 1392 | 25 SQMM, 3 CORE |
| 1393 | 4.0 Sq.mm x 3 Core |
| 1394 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 1395 | Hot Dipped Galvanized |
| 1396 | 450mm x 50mm x 2.0mm |
| 1397 | 600mm x 50mm x 2.0mm |
| 1398 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 1399 | Hot Dipped Galvanized |
| 1400 | 100mm x 50mm x 1.6mm |
| 1401 | 150mm x 50mm x 1.6mm |
| 1402 | 300mm x 50mm x 1.6mm |
| 1403 | 450mm x 50mm x 2.0mm |
| 1404 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 1405 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 1406 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1407 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1408 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1409 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1410 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1411 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1412 | 125 A MCCB (Fixed type )as outgoing CT\"s, Ampermeter with SS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)600(H)X1000(D) |
| 1413 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 1414 | 22KW |
| 1415 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowingrating |
| 1416 | 11KW |
| 1417 | 18.5KW |
| 1418 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 1419 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 1420 | Local Push Button Station |
| 1421 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 1422 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 1423 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 1424 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 1425 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 1426 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 1427 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 1428 | Chlorinators 1 kg/Hr Capacity) |
| 1429 | Chlorine Tonner 900 Kg |
| 1430 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 1431 | Chlorinator Room |
| 1432 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 1433 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 1434 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 1435 | 1.5 KW (2.0 HP) |
| 1436 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 1437 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 1438 | Part-04: C- Construction ofPump house atAKLERA PH |
| 1439 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At AKLERA Head work near proposed 900 KL CWR (For Installation of 1W+1S Pumps+1 future pump) |
| 1440 | Mechanical Equipment & Accessories |
| 1441 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 1442 | Route 1-23.18 LPS / 50 m head/25 KW |
| 1443 | Route 2-13.78 LPS /55 m head/15 KW |
| 1444 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 1445 | 100mm dia- 5mm thk |
| 1446 | 125mm dia- 5mm thk |
| 1447 | 150mm dia- 5mm thk |
| 1448 | 200mm dia- 5mm thk |
| 1449 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 1450 | 100mm dia- 5mm thk |
| 1451 | 125mm dia- 5mm thk |
| 1452 | 150mm dia- 5mm thk |
| 1453 | 200mm dia- 5mm thk |
| 1454 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 1455 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 1456 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1457 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 1458 | 100 mm dia |
| 1459 | 150 mm dia |
| 1460 | 200 mm dia |
| 1461 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1462 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 1463 | 100 mm dia |
| 1464 | 125 mm dia |
| 1465 | 150 mm dia |
| 1466 | 200 mm dia |
| 1467 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1468 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 1469 | 100 mm dia |
| 1470 | 150 mm dia |
| 1471 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1472 | 100 mm dia |
| 1473 | 150 mm dia |
| 1474 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 1475 | 100 mm dia |
| 1476 | 125 mm dia |
| 1477 | 150 mm dia |
| 1478 | Electric Overhead Travelling (EOT) Crane |
| 1479 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 1480 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 1481 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 1482 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 1483 | 50 mm |
| 1484 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 1485 | - 1.0 to +1.0 kg/cm² |
| 1486 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 1487 | EFM100 mm |
| 1488 | EFM 150 mm |
| 1489 | Water meter chamber: |
| 1490 | Chamber |
| 1491 | Electric equipment and accessories |
| 1492 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 1493 | 100KVA |
| 1494 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 1495 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 1496 | 110VDC |
| 1497 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 1498 | 25 A + 25 A |
| 1499 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1500 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1501 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 1502 | 50mm x 6mm copper strip |
| 1503 | 50mm x 6mm G.I. Strip |
| 1504 | 32mm x6mm G.I. Strip |
| 1505 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 1506 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 1507 | 3 core 120.0 Sq.mm |
| 1508 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 1509 | Indoor |
| 1510 | 3 core 120/150/185 Sq.mm |
| 1511 | Outdoor |
| 1512 | 3 core 120/150/185/225 Sq.mm |
| 1513 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 1514 | 70 SQMM,3.5 CORE |
| 1515 | 35 SQMM, 3 CORE |
| 1516 | 16 SQMM, 3 CORE |
| 1517 | 4.0 Sq.mm x 3 Core |
| 1518 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 1519 | Hot Dipped Galvanized |
| 1520 | 450mm x 50mm x 2.0mm |
| 1521 | 600mm x 50mm x 2.0mm |
| 1522 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 1523 | Hot Dipped Galvanized |
| 1524 | 100mm x 50mm x 1.6mm |
| 1525 | 150mm x 50mm x 1.6mm |
| 1526 | 300mm x 50mm x 1.6mm |
| 1527 | 450mm x 50mm x 2.0mm |
| 1528 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 1529 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 1530 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1531 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1532 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1533 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1534 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1535 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1536 | 125 A MCCB (Fixed type )as outgoing CT\"s, Ampermeter with SS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)600(H)X1000(D) |
| 1537 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 1538 | 30KW |
| 1539 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowingrating |
| 1540 | 15KW |
| 1541 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 1542 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 1543 | Local Push Button Station |
| 1544 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 1545 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 1546 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 1547 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 1548 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 1549 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 1550 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 1551 | Chlorinators 1 kg/Hr Capacity) |
| 1552 | Chlorine Tonner 900 Kg |
| 1553 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 1554 | Chlorinator Room |
| 1555 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 1556 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 1557 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 1558 | 1.5 KW (2.0 HP) |
| 1559 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 1560 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 1561 | Part-04: C- Construction ofPump house atKALANDA PH |
| 1562 | ConstructionofPumphouseofrequiredsizesuitableforinstallationof maximum 4 no. monoblock pump sets as per approved GA drawing, scope ofworkandtechnicalspecificationcompleteworkinallrespect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.At KALANDA Head worknear proposed 1300 KL CWR (For Installation of 2W+2S Pumps & 2 pumps for future ) |
| 1563 | Mechanical Equipment & Accessories |
| 1564 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casingring,SS316impeller,SS410Shaftandshaftsleeve,couplingguard, common base plate, foundation bolts, Cement concrete foundation etc. completewithallrespectasperthespecificationandscopeofworkand direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 1565 | Route 1-17.62 LPS / 70 m head/25 KW |
| 1566 | Route 2-16.65 LPS /75 m head/25 KW |
| 1567 | Route 3-19.06 LPS /75 m head/30 KW |
| 1568 | Route 4-39.00 LPS /65 m head/40 KW |
| 1569 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 1570 | 125mm dia- 5mm thk |
| 1571 | 150mm dia- 5mm thk |
| 1572 | 250mm dia- 5mm thk |
| 1573 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 1574 | 125mm dia- 5mm thk |
| 1575 | 150mm dia- 5mm thk |
| 1576 | 250mm dia- 5mm thk |
| 1577 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsintrenchescompleteincluding alltaxes,material, labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecifications anddirection of Engineer in-charge. |
| 1578 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
| 1579 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1580 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 on individual dischrge pipe |
| 1581 | 125 mm dia |
| 1582 | Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirfingtoBS-EN-1171/AWWAC-509andoffollowing specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1583 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 on suction & common delivery |
| 1584 | 125 mm dia |
| 1585 | 150 mm dia |
| 1586 | 250 mm dia |
| 1587 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves ofapproved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1588 | Class PN 1.6, Motorised Operated on Individual Discharge pipe |
| 1589 | 125 mm dia |
| 1590 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1591 | 125 mm dia |
| 1592 | Providing, installation, testing and commissioning of following Stain less steel AISI304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 1593 | 125 mm dia |
| 1594 | 150 mm dia |
| 1595 | 250 mm dia |
| 1596 | Electric Overhead Travelling (EOT) Crane |
| 1597 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 1598 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. |
| 1599 | 2 MT Capacity(Span 9 M and Lift 6 M) |
| 1600 | Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammendeduptodate) Body,Highpressurecover , Lowpressurecover,Cowland Jointsupportring-Ductilecastironofgrade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball:AISI304stainlessSteel,Seatring&Gasket-EPDM/NBR,HPOrifice&HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 1601 | 50 mm |
| 1602 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 1603 | - 1.0 to +1.0 kg/cm² |
| 1604 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, andallmaterialsrequiredformakingconnectionwithexistingpipeline includingcuttingtheexistingpipelineetc.completeinallrespectasper technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 1605 | EFM125 mm |
| 1606 | EFM 200 mm |
| 1607 | Water meter chamber: |
| 1608 | Chamber |
| 1609 | Electric equipment and accessories |
| 1610 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 1611 | 250KVA |
| 1612 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
| 1613 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 1614 | 110VDC |
| 1615 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 1616 | 25 A + 25 A |
| 1617 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1618 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1619 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 1620 | 50mm x 6mm copper strip |
| 1621 | 50mm x 6mm G.I. Strip |
| 1622 | 32mm x6mm G.I. Strip |
| 1623 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 1624 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 1625 | 3 core 120.0 Sq.mm |
| 1626 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 1627 | Indoor |
| 1628 | 3 core 120/150/185 Sq.mm |
| 1629 | Outdoor |
| 1630 | 3 core 120/150/185/225 Sq.mm |
| 1631 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 1632 | 185 SQMM,3.5 CORE |
| 1633 | 50 SQMM, 3 CORE |
| 1634 | 35 SQMM, 3 CORE |
| 1635 | 4.0 Sq.mm x 3 Core |
| 1636 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 1637 | Hot Dipped Galvanized |
| 1638 | 450mm x 50mm x 2.0mm |
| 1639 | 600mm x 50mm x 2.0mm |
| 1640 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 1641 | Hot Dipped Galvanized |
| 1642 | 100mm x 50mm x 1.6mm |
| 1643 | 150mm x 50mm x 1.6mm |
| 1644 | 300mm x 50mm x 1.6mm |
| 1645 | 450mm x 50mm x 2.0mm |
| 1646 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
| 1647 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 1648 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1649 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 1650 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1651 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1652 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1653 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 1654 | 250AMCCB(Fixedtype)asoutgoingCT\"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D) |
| 1655 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 1656 | 30KW |
| 1657 | 45KW |
| 1658 | 433V APFC Panelin cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 1659 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 1660 | Local Push Button Station |
| 1661 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 1662 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 1663 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements. |
| 1664 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
| 1665 | Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets.30 KVA at 0.8 pf 415V 50Hz 3-? |
| 1666 | Supply,installation,testingandcommissioningof MNREapprovedGridtied SolarPanelswithinverter, meter,cable etc.suitable forRooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty.WorkincludesdesigningofsolarpanelareaandMSframeand foundationonground/roofofPumphouseorCWR,showingarrangementof panelinavailablespace,installationof PVmoduleonMSframeasper approved design and drawings. Mountingstructure shall be suitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiencyof>98%.ConnectuptomultiplestringsPVarrays,Easy&fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note:Thereshallbe 5year servicewarranty forpanel, inverter,meter, cable etc. andsuitable provision shall be included in tender document. |
| 1667 | Providing,installation, testingandcommisioningofvacuumFeed Gas Chlorinator with all assessories and making connection with existing pipeline requiredincludingsupply & instalationof trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragmValveon injectorinlet& outlet,32 ODuPVCpipefor chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GMgatevalveonpumpsuction&delivery,25NBGM\"Y\"type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressuregauge with Isolatedvalve on pump deliveryand chlorine boosterpumpwithmotorofrequiredcapacity completeinall respect as per specification and the direction of the Engineer. |
| 1668 | Chlorinators 1 kg/Hr Capacity) |
| 1669 | Chlorine Tonner 900 Kg |
| 1670 | Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, hand chain encased gears, trolley trolley track, wheels, axle & shaft, swivel type lifting hook for 2 MT capacity, 6 m lift and 7 m span |
| 1671 | Chlorinator Room |
| 1672 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonaryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 1673 | Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, squarebars,flatsorblackpipewithholdfastandfitting completeas per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 1674 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 1675 | 1.5 KW (2.0 HP) |
| 1676 | Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: |
| 1677 | ISI marked 10 kg capacity Dry Powder fire xtinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power.Both extinguisher and dry power to be ISI marked. |
| 1678 | Campus Development( Including Lighting works, Horticulture, Drainage, CC Roads and RWH etc.) atAll cluster Pump Houses |
| 1679 | A- Drainage |
| 1680 | Providing and fixing of reinforced Ferro-Cement drain covers designed for \"A\" & \"AA\" class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. |
| 1681 | For Class - \"A\" loading |
| 1682 | Span 300 to 450 mm Standard size 600x800mm |
| 1683 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. |
| 1684 | Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks |
| 1685 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 1686 | Providing and Laying Reinforced cement concrete pipe NP4/ prestrssed concrete pipe for culverts including jointing ends and fixing collar with cement mortar 1:2 complete as per clause 1000 & 2900 of MoRT&H specification including all material, labour form work, machinery. |
| 1687 | 200 mm internal diameter |
| 1688 | B- Horticulture |
| 1689 | Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit to required compaction as per MoRT&H specification clause 201. (Measurment of girth to be done at height of 1 m above ground level) |
| 1690 | Girth from 300 mm to 600 mm |
| 1691 | Clearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres as per MoRT&H specification clause 201. |
| 1692 | Supply of dry manure including loading unloading, transportation & stacking at site. |
| 1693 | Farm yard manure (organic) |
| 1694 | Compost |
| 1695 | Goat dungmanure |
| 1696 | Supply & Stacking good earth at site complete including loading unloading & transporation etc. |
| 1697 | Supply of insecticides & pesticides at store in dust/liquid form complete |
| 1698 | Methly Prathion 2% |
| 1699 | Supply of different varities of tree/ shrubs/climbers according to height and age of the plant at site including loading/unloading & transportation etc. complete: |
| 1700 | Different flowing plants 900 mm to 1500 mm (Rs 50 to Rs 150) |
| 1701 | Different varrities of shrubs 600 mm to 900 mm (Rs 25 to Rs 160) |
| 1702 | Different varrities of climbers 900 mm to 1500 mm (Rs 48 to Rs 144) |
| 1703 | Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to bepaid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration ofplanting if lawn die some where the contractor will replant it at his own cost |
| 1704 | In rows 7.5 Cms. apart in either direction |
| 1705 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee,bend etc.), satisfactory hydraulic testing, disinfection etc.complete as per technical specifications and direction of Engineer-in-charge of following class and diameter.(excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. |
| 1706 | HDPE PE-100 PN-6 |
| 1707 | 75 mm dia |
| 1708 | P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. |
| 1709 | 15mm dia nominal bore \"B Class\" |
| 1710 | C- Campus Road & Light |
| 1711 | Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
| 1712 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified,complete work as per technical specification and scope of work. |
| 1713 | M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mmnominal size). |
| 1714 | S & F cement concrete pre cast Kerb or Dand up to 60 cm length over 20 mm thick base of cement mortar1:4 including jointing earth work, pointing & jointing with cement mortar 1:4 of size Including cost of M- 20 Mix Dand/ Kerb Complete |
| 1715 | 20x20 cm |
| 1716 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 1717 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required |
| 1718 | 1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 1719 | Supply and erection of hot dipped galvanised steel swaged tubular pole /GI Conical Pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate of size 400mm x 400mm x 7mm in position including excavation of the pit and filling the same with C.C. of M- 10/M-20 grade (1:3:6)/ grade(1:1.5:3) from base plate to 50cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals , cable entry, GI cable sleeve complete as required. The pole shall be galvanised using ISI mark tube for structural purpose. |
| 1720 | 7.5 Mtr. height |
| 1721 | Add for supply and fixing of hot dipped galvanised Overhang of following size over the existing poles |
| 1722 | 76.1mm OD x 3.25mm thickness |
| 1723 | P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. |
| 1724 | LED street light fixture 60 Watt |
| 1725 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 1726 | 10.0 Sq.mm, 4 core |
| 1727 | D- Construction of RWH Structure |
| 1728 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. |
| 1729 | Collection Chamber |
| 1730 | Silting Chamber |
| 1731 | Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering =All up to plinth leve |
| 1732 | 1:4:8 (1Cement :4 Course Sand :8 Graded stone aggregate 40 mm nominal size |
| 1733 | Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks I 1:6 cement Martar |
| 1734 | 1:2:4 (1Cement :2 Course Sand 4 Graded stone aggregate 20 mm nominal size |
| 1735 | Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish: |
| 1736 | 25 mm thick. |
| 1737 | Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with \"code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will include cost of casing pipe and strainer pipe assembly, gravel and development work etc. The work shall be completed as per technical specifications anddirection of EIC. |
| 1738 | 250 mm |
| 1739 | Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids |
| 1740 | Size 9 to 12 mm |
| 1741 | Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. |
| 1742 | Part-06:Construction of Civil Building at WTP |
| 1743 | Officers Residences (EE) - 1 Nos @ 160 sqm each |
| 1744 | Officers Residences (AE) - 2 Nos @ 120 sqm each |
| 1745 | J-2 Type Full Set 12 nos @ 120 Sqm each pump house |
| 1746 | Store Shed-12 Nos @ 35 sqm each pump house |
| 1747 | DG Shed-12 Nos @ 25 sqm each pump house |
| 1748 | Parking Shed -12 Nos @ 25 sqm each pump house |
| 1749 | Part-07C: PLC Scada at Khajurna Kalan |
| 1750 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1751 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1752 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1753 | 2KVA |
| 1754 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1755 | 1 SQMM, 24 Core |
| 1756 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1757 | 1 SQMM, 1 Pair |
| 1758 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1759 | 4C x 2.5 sq.mm |
| 1760 | 4C x 1.5 sq.mm |
| 1761 | 8C x 2.5 sq.mm |
| 1762 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1763 | 0-5M |
| 1764 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1765 | 1/2\" M (NPT) |
| 1766 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1767 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1768 | 0.05 -20 mg/l |
| 1769 | Part-07C: PLC Scada at Aklera |
| 1770 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1771 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1772 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1773 | 2KVA |
| 1774 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1775 | 1 SQMM, 24 Core |
| 1776 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1777 | 1 SQMM, 1 Pair |
| 1778 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1779 | 4C x 2.5 sq.mm |
| 1780 | 4C x 1.5 sq.mm |
| 1781 | 8C x 2.5 sq.mm |
| 1782 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1783 | 0-5M |
| 1784 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1785 | 1/2\" M (NPT) |
| 1786 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1787 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1788 | 0.05 -20 mg/l |
| 1789 | Part-07C: PLC Scada at Kalanda |
| 1790 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1791 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1792 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1793 | 2KVA |
| 1794 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1795 | 1 SQMM, 24 Core |
| 1796 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1797 | 1 SQMM, 1 Pair |
| 1798 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1799 | 4C x 2.5 sq.mm |
| 1800 | 4C x 1.5 sq.mm |
| 1801 | 8C x 2.5 sq.mm |
| 1802 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1803 | 0-5M |
| 1804 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1805 | 1/2\" M (NPT) |
| 1806 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1807 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1808 | 0.05 -20 mg/l |
| 1809 | Part-07C: PLC Scada at Relawan |
| 1810 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1811 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1812 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1813 | 2KVA |
| 1814 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1815 | 1 SQMM, 24 Core |
| 1816 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1817 | 1 SQMM, 1 Pair |
| 1818 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1819 | 4C x 2.5 sq.mm |
| 1820 | 4C x 1.5 sq.mm |
| 1821 | 8C x 2.5 sq.mm |
| 1822 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1823 | 0-5M |
| 1824 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1825 | 1/2\" M (NPT) |
| 1826 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1827 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1828 | 0.05 -20 mg/l |
| 1829 | Part-07C: PLC Scada at Karwari Kalan |
| 1830 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1831 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1832 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1833 | 2KVA |
| 1834 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1835 | 1 SQMM, 24 Core |
| 1836 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1837 | 1 SQMM, 1 Pair |
| 1838 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1839 | 4C x 2.5 sq.mm |
| 1840 | 4C x 1.5 sq.mm |
| 1841 | 8C x 2.5 sq.mm |
| 1842 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1843 | 0-5M |
| 1844 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1845 | 1/2\" M (NPT) |
| 1846 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1847 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1848 | 0.05 -20 mg/l |
| 1849 | Part-07C: PLC Scada at Bajrang garh |
| 1850 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1851 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1852 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1853 | 2KVA |
| 1854 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1855 | 1 SQMM, 24 Core |
| 1856 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1857 | 1 SQMM, 1 Pair |
| 1858 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1859 | 4C x 2.5 sq.mm |
| 1860 | 4C x 1.5 sq.mm |
| 1861 | 8C x 2.5 sq.mm |
| 1862 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1863 | 0-5M |
| 1864 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1865 | 1/2\" M (NPT) |
| 1866 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1867 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1868 | 0.05 -20 mg/l |
| 1869 | Part-07C: PLC Scada at Bhawangarh |
| 1870 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1871 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1872 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1873 | 2KVA |
| 1874 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1875 | 1 SQMM, 24 Core |
| 1876 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1877 | 1 SQMM, 1 Pair |
| 1878 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1879 | 4C x 2.5 sq.mm |
| 1880 | 4C x 1.5 sq.mm |
| 1881 | 8C x 2.5 sq.mm |
| 1882 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1883 | 0-5M |
| 1884 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1885 | 1/2\" M (NPT) |
| 1886 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1887 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1888 | 0.05 -20 mg/l |
| 1889 | Part-07C: PLC Scada at Banda Kalan |
| 1890 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1891 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1892 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1893 | 2KVA |
| 1894 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1895 | 1 SQMM, 24 Core |
| 1896 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1897 | 1 SQMM, 1 Pair |
| 1898 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1899 | 4C x 2.5 sq.mm |
| 1900 | 4C x 1.5 sq.mm |
| 1901 | 8C x 2.5 sq.mm |
| 1902 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1903 | 0-5M |
| 1904 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1905 | 1/2\" M (NPT) |
| 1906 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1907 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1908 | 0.05 -20 mg/l |
| 1909 | Part-07C: PLC Scada at Ranibarod |
| 1910 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1911 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1912 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1913 | 2KVA |
| 1914 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1915 | 1 SQMM, 24 Core |
| 1916 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1917 | 1 SQMM, 1 Pair |
| 1918 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1919 | 4C x 2.5 sq.mm |
| 1920 | 4C x 1.5 sq.mm |
| 1921 | 8C x 2.5 sq.mm |
| 1922 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1923 | 0-5M |
| 1924 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1925 | 1/2\" M (NPT) |
| 1926 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1927 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1928 | 0.05 -20 mg/l |
| 1929 | Part-07C: PLC Scada at Kasba Thana |
| 1930 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1931 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1932 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1933 | 2KVA |
| 1934 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1935 | 1 SQMM, 24 Core |
| 1936 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1937 | 1 SQMM, 1 Pair |
| 1938 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1939 | 4C x 2.5 sq.mm |
| 1940 | 4C x 1.5 sq.mm |
| 1941 | 8C x 2.5 sq.mm |
| 1942 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1943 | 0-5M |
| 1944 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1945 | 1/2\" M (NPT) |
| 1946 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1947 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1948 | 0.05 -20 mg/l |
| 1949 | Part-07C: PLC Scada at Kaloni |
| 1950 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1951 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1952 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1953 | 2KVA |
| 1954 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1955 | 1 SQMM, 24 Core |
| 1956 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1957 | 1 SQMM, 1 Pair |
| 1958 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1959 | 4C x 2.5 sq.mm |
| 1960 | 4C x 1.5 sq.mm |
| 1961 | 8C x 2.5 sq.mm |
| 1962 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1963 | 0-5M |
| 1964 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1965 | 1/2\" M (NPT) |
| 1966 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1967 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1968 | 0.05 -20 mg/l |
| 1969 | Part-07C: PLC Scada at Kushayar CWR |
| 1970 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 1971 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 1972 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 1973 | 2KVA |
| 1974 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1975 | 1 SQMM, 24 Core |
| 1976 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 1977 | 1 SQMM, 1 Pair |
| 1978 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1979 | 4C x 2.5 sq.mm |
| 1980 | 4C x 1.5 sq.mm |
| 1981 | 8C x 2.5 sq.mm |
| 1982 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1983 | 0-5M |
| 1984 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 1985 | 1/2\" M (NPT) |
| 1986 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 1987 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
| 1988 | 0.05 -20 mg/l |
| 1989 | Part-07C: PLC Scada at ESRs |
| 1990 | Modular RTU complete with DI, DO, AI and modbus communication ports and power supply 24 VDC or for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Tele Control Basic,DNP3,IEC60870-5-104andCommunicationprotocols,on-board I/Os min. (8 DI, 4 DQ, 2 AI), configuration and diagnostics per webinterface,RJ45port,mobilecommunicationsantenna (GSM/UMTS),MiniSIMcard,withadapterMicroSIMcardalso, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for Compact RTU Location, wall/floormountedalongwithwiringandrelatedaccessoriesand arrangement of mounting of RTU, Modem having IP-5X Protection. Panels shall be self-fabricate type only with Canopy. |
| 1991 | Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation ofPV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document. |
| 1992 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 1993 | 0-5M |
| 1994 | Earthing Schedule Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 1995 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.25mm x 3mm GI strip |
| 1996 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (1 Pair * 0.75SQMM) |
| 1997 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 1998 | 4C x 1.5 sq.mm |
| 1999 | Part-07C: PLC Scada at VTCs |
| 2000 | Supply of GSM /GPRSbased data transmitter for Bulk Flowmeter (woltman Pulse Output only ), Battery Powered -7.4V,battery life 3-5 Years,(1 no Data transmit in aday),4-20mA From Pressure RS485 Display-16*2 LCD,Encloser-165*120*65 mm,ABS Protection-IP65,Operating tempreature -55 Deg. C |
| 2001 | Cost for Basic Service Charges, Administration and Management, Running of Office, Staff Quarters, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants,chlorine gas, PAC, all other chemicals, Consumables, Spare Partsetc.as per scope & specifications/terms & conditions of contract. No amount will be paid for O&M in DLP. |
| 2002 | For the 1st year of O&M after DLP |
| 2003 | For the 2nd year of O&M after DLP |
| 2004 | For the 3rd yearof O&M after DLP |
| 2005 | For the 4th yearof O&M after DLP |
| 2006 | For the 5th yearof O&M after DLP |
| 2007 | For the 6th yearof O&M after DLP |
| 2008 | For the 7th yearof O&M after DLP |
| 2009 | For the 8th yearof O&M after DLP |
| 2010 | For the 9th yearof O&M after DLP |
| 2011 | For the 10th yearof O&M after DLP |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail