Tender For Renovation And Interior Furnishing Work For The Library Of Shaheed Bhagat Singh College At Sheikh Sarai ,New Delhi -110017, Delhi-Delhi

Delhi University has published Tender For Renovation And Interior Furnishing Work For The Library Of Shaheed Bhagat Singh College At Sheikh Sarai ,New Delhi -110017. Submission Date for this Tender is 08-04-2024. Interior Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42768647
Corrigendum : Tender For Renovation And Interior Furnishing Work For The Library Of Shaheed Bhagat Singh College At Sheikh Sarai ,New Delhi -110017
Open Tender
Indian
Delhi
Delhi
08-04-2024

Tender Details

Renovation And Interior Furnishing Work For The Library Of Shaheed Bhagat Singh College At Sheikh Sarai ,New Delhi -110017 As Per Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Mar-2024 Date Extended Date 08-04-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 360000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : RENOVATION AND INTERIOR OF LIBRARY AT SHAHEED BHAGAT SINGH COLLEGE,SHEIKH SARAI-II, NEW DELHI-110017
Sl. No. Item Description
1CIVIL WORK
2SUB HEAD :- PCC WORK 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
3SUB HEAD :- RCC WORK Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
4SUB HEAD :- RCC WORK Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
5SUB HEAD :- FORM WORK Suspended floors, roofs, landings, balconies and access platform
6SUB HEAD :- FORM WORK Lintels, beams, plinth beams, girders, bressumers and cantilevers
7SUB HEAD :- FORM WORK Columns, Pillars, Piers, Abutments, Posts and Struts
8SUB HEAD :- FORM WORK Edges of slabs and breaks in floors and walls Under 20 cm wide
9SUB HEAD :- STEEL REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
10SUB HEAD :- HALF BRICK MASONRY Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
11SUB HEAD :- HALF BRICK MASONRY Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand)
12SUB HEAD :-HALF BRICK MASONRY Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
13SUB HEAD :- STONE WORK Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels, all complete as per direction of SBSC/ Consultant. Granite of any colour and shade Area of slab upto 0.50 sqm
14SUB HEAD :- STONE WORK Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge, all complete as per direction of SBSC/ Consultant. Granite Work
15SUB HEAD :- STONE WORK Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
16SUB HEAD :- STONE WORK Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
17SUB HEAD :- WOOD WORK & PVC WORK Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
18SUB HEAD :- WOOD WORK & PVC WORK Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
19SUB HEAD :- WOOD WORK & PVC WORK Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
20SUB HEAD :- WOOD WORK & PVC WORK Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
21SUB HEAD :- WOOD WORK & PVC WORK Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square
22SUB HEAD :- WOOD WOK & PVC WORK Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm
23SUB HEAD :- WOOD WORK & PVC WORK Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
24SUB HEAD :- WOOD WORK & PVC WORK Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
25SUB HEAD :- WOOD WORK & PVC WORK Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
26SUB HEAD :- WOOD WOEK & PVC WORK Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
27SUB HEAD :- WOOD WORK & PVC WORK Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
28SUB HEAD :- WOOD WORK & PVC WORK Providing and fixing fly proof stainless steel grade 304 wire gauge,to window and clerestory window using wire gauge with average width of apreture 1.4 mm in both directions with wire of dia 0.50 mm , all complete as per direction of SBSC/ Consultant. With 2nd class teak wood beading 62x19 mm
29SUB HEAD :- WOOD WORK & PVC WORK Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per direction of SBSC/ Consultant. Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm andsingle glass pane glazing beadof appropriate dimension. (Area of window upto 0.75 sqm.).
30SUB HEAD :- WOOD WORK & PVC WORK Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm andsingle glass pane glazing beadof appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm.).
31SUB HEAD :- STEEL WORK Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
32SUB HEAD :- STEEL WORK Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
33SUB HEAD :-FLOORING WORK Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
34SUB HEAD :- FLOORING WORK Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding pointing the joints with white cement and matching pigments etc., complete.
35SUB HEAD :- FLOORING WORK Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufscturer) with water absorption less than 0.08% and confirming to IS:15622,of approved make,in all coours and shades,laid on 20mm thick cement morter 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigment etc, all complete as per direction of SBSC/ Consultant. Size of Tile 600x600 mm
36SUB HEAD :- FLOORING WORK Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm, all complete as per direction of SBSC/ Consultant.
37SUB HEAD :- FLOORING WORK Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness, all complete as per direction of SBSC/ Consultant.
38SUB HEAD :- FLOORING WORK Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc, all complete as per direction of SBSC/ Consultant. Size of Tile 600x600 mm
39SUB HEAD :- ROOFING WORK Providing and fixing in position 25 mm thick IInd Class Teakwood for soffit / false ceiling finished with melamine polished including 25 x 25mm thick IIclass TW wooden frame work/ supports, suspended from RCC ceiling& mouldings, groove, with melamine polish, all complete as per direction of SBSC/ Consultant.
40SUB HEAD :-ROOFING WORK Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
41SUB HEAD :- ROOFING WORK Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
42SUB HEAD :-ROOFING WORK Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
43SUB HEAD :-FINISHING WORK Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete, all complete as per direction of SBSC/ Consultant.
44SUB HEAD :- FINISHING WORK Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood), all complete as per direction of SBSC/ Consultant.
45SUB HEAD :- FINISHING WORK Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade, all complete as per direction of SBSC/ Consultant. Two or more coats on new work
46SUB HEAD :- DISMENTALLING & REPAIRINGWORK Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead, all complete as per direction of SBSC/ Consultant. Of area 3 sq. metres and below
47SUB HEAD :- DISMENTALLING & REPAIRINGWORK Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
48SUB HEAD :- DISMENTALLING & REPAIRINGWORK Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.
49SUB HEAD :- DISMENTALLING & REPAIRINGWORK Dismentling and taking out of electrical wires, switch, sockets & fittings and disposal of material within 50 metres lead, all complete as per direction of SBSC/ Consultant.
50SUB HEAD :- DISMENTALLING & REPAIRINGWORK Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of SBSC/ Consultant.
51SUB HEAD :- PLUMBINGWORK Providing and fixing White vitreous wash basin Make- Jaquar CatNo. JDS-WHT-25907 Size -375x475x130 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
52SUB HEAD :- PLUMBING WORK Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
53SUB HEAD :- PLUMBING WORK Providing and fixing CP Brass 40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
54SUB HEAD :- PLUMBING WORK Providing & fixingSensotronic Sensor Faucet for wash basin deck mounted. Make- Jaquar CatNo.-SNR-CHR-51021 or equivalent as per Engineer- in -Charge / Consultant.
55SUB HEAD :- PLUMBING WORK Providing and fixing Braided Hoses with Two 15mm CP Brass Nuts & Rubber Washers Without Nipple (Suitable for Geysers and basins).Make- Jaquar CatNo.- ALD-805B or equivalent as per Engineer- in -Charge / Consultant . 45 cm length 15 mm nominal bore
56SUB HEAD :- PLUMBING WORK Providing & fixing ofWall Mounted Paper towel dispensers towels with C/Z folds capacity: 400-600 C/Z towels made of AISI 304 Stainless Steel with Satin finished. The towel tray opening has bound edges to minimise tearing of paper towels. Door fixed to the body with two rivets, allowing it to be swung open for replenishment.Slot for viewing content level on the front.Make- Jaquar CatNo.-SNR-CHR-51021 or equivalent as per Engineer- in -Charge / Consultant.
57SUB HEAD :- PLUMBING WORK Providing and Fixing of Health Faucet Kit (Flexible Chrome Hose, Handset & Bracket) allcomplete including CP flange etc. Make- Jaquar CatNo.- ALD-CHR-573 or equivalent as per Engineer- in -Charge / Consultant.
58SUB HEAD :- PLUMBING WORK Providing & fixingTowel Ring Squarewith C.P. brass wall brackets & C.P brass screws complete as required. Make- Jaquar Cat No.- AKP-35721P or equivalent as per Engineer- in -Charge / Consultant. Size 600 x 20 mm size
59SUB HEAD :- PLUMBING WORK Providing and fixing C.P. brass angle valve for basin mixer & geyser points of approved quality conforming to IS:8931 - 15mm nominal bore
60SUB HEAD :- PLUMBING WORK Providing and fixing of Sensor Operated Optimum Hand Dryers -Weld-free cover fixed to the base with 4 Allen bolts. Base in ABS thermoplastic UL 94-V0. Thermoplastic fan wheel PA6 UL 94-V0. Class F induction motor incorporating a safety thermal cut-off. PP UL 94-V0 aluminium centrifugal single inlet fan wheel. Heating element incorporating a safety thermal cut-off. Electronic infrared detection sensor. Adjustable detection adjustable (15-25 cm). .Make-Jaquar Cat.No.-HDR-SAP-M99ACS or Equivalent as per direction of Engineer - in - charge /Consultant .
61SUB HEAD :- PLUMBING WORK roviding& Fixing Automatic soap dispensor Capecity-0.8 L. made by aluminium / ABS with Chrome finished .Make-Jaquar Cat.No.- SDR-BLC-DJ0160AS or Equivalent as per direction of Engineer - in - charge /Consultant.
62SUB HEAD :- PLUMBING WORK Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
63SUB HEAD :- PLUMBING WORK Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal.
64SUB HEAD :- PLUMBING WORK Providing and fixing C.P. brass extension nipple (size 15mm x 50mm) of approved make and quality as per direction of engineer-in-charge
65SUB HEAD :- PLUMBING WORK Providing and fixing horzontal/vertical Hot water geyser made of MS body with copper jacket inside with necessary inlet, outlet, drain, overflow, vent and all safety accessories etc. complete including cutting and making good the walls, wherever required.Make- Jaquar Erica Vertical or Equivalent as per dierction of Engineer-in-charge/ Consultant. 25 lit for bathroom
66SUB HEAD :- PLUMBING WORK Providing & fixing Curved shape chrome finished urinal partition with 10mm thick frosted glasssize-(900mm x 450mm).Make- Jaquar-Cat No.-JSE-CHR-1110UC or Equivalent as per dierction of Engineer-in-charge/ Consultant.
67SUB HEAD :- PLUMBING WORK Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
68SUB HEAD :- PLUMBING WORK Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge (Cement shall be free issue material): Concealed work including cutting chases and making good the walls etc: 15 mm nominal outer dia Pipes
69SUB HEAD :- PLUMBING WORK Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge (Cement shall be free issue material): Concealed work including cutting chases and making good the walls etc: 20 mm nominal outer dia Pipes
70SUB HEAD :- PLUMBING WORK Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge (Cement shall be free issue material): Concealed work including cutting chases and making good the walls etc: 25 mm nominal outer dia Pipes
71SUB HEAD :-PLUMBING WORK Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge (Cement shall be free issue material): Concealed work including cutting chases and making good the walls etc: 32 mm nominal outer dia Pipes
72SUB HEAD :-PLUMBING WORK Providing & fixing UPVC soil, waste, vent pipework comprising UPVC pipe conforming toIS :4985-1983 and of required class as specified below and fittings (moulded as well as fabricated) like elbows, bends, reducers, threaded tail pieces, caps andand other specials.jointing with cement solvent, chasing, cutting and making good the walls, complete in all respects including testing of complete installation. 75 mm dia
73SUB HEAD :-PLUMBING WORK Providing & fixing UPVC soil, waste, vent pipework comprising UPVC pipe conforming toIS :4985-1983 and of required class as specified below and fittings (moulded as well as fabricated) like elbows, bends, reducers, threaded tail pieces, caps andand other specials.jointing with cement solvent, chasing, cutting and making good the walls, complete in all respects including testing of complete installation. 100mm dia
74SUB HEAD :- WATERPROOFING WORK Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
75SUB HEAD :- SANDWICH WALL PANEL Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core panels made of core material of EPS granule balls/beads (conforming to IS 4671:1984 and shall have density not less than 15kg per cum) adhesive, cement, sand, flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fiber cement board confirming to IS 14862:2000 or Calcium silicate board confirming to EN 14306:2009 of 5mm thick each. Panel shall be laid on 6mm thick cement mortar (1 cement: 2 fine sand) mixed with chemical adhesive of 0.5kg per 50kg of cement orshall be preferably fixed into "C" channel made of 1.2mm thick MS plate screwed/fastenened to the slab/column/beam etc. The panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Cost of all the material is included except "C channel" which will be paid seperately). Non load bearing panels 75mm thick of required size
76INTERIOR WORK
77Wooden Partition with Laminate finish. Providing & Fixing solid partition, the framing shall made out of aluminium hollow section of 47mm x 40mm size2.15 mm thick of Jindal/ Indal as internal frame structure placed horizontally & vertically at max. distance of 2"0 " x 2"0" centre to centrewith 8+6mm thk. Commercial ply on both sides over 1 mm thick High glossy Premium laminate of approved shade and veneer finished with 3 coats of melamine polish as per architects instructions. Note :(i) All ply to be sprayed with anti-termite & anti-borer spray (ii) Rate to include all necessary supports & as per details (iii ) Measurements to be recorded upto finished false ceiling level, all complete as per direction of SBSC/ Consultant.
78Low ht. Solid Partition :- Providing and fixing solid partition , theframing shallmade out of aluminium hollow section of 53mm x 38.1mm size 2.15mm thick of JINDAL / INDAL as internal frame structure placed horizontally & vertically at max distance of 2’-0” x 2"-0" center to center. Fixing8+6 mm thick commercial ply on both sides with 1.0mm thick laminateon topof approved shade with groove pattern as per instructions of Architect. The shade of laminatefinish to be got approved by Engineer-in-Charge /Consultant. The skirting should be as per approved laminate as per drawing and direction. Rate shall be inclusive of necessary hardware items, etc. Complete. The edge beadings with steam beach wood should be finished with PU coating if required including providing & fixing steam beech wooden coping as per Architect Design on horizontal and vertical exposed ends of low height partition polished with PU coatedfinished complete in all respect.Providing and Fixing inserted Soft board / White boards / Glass maintaining the vertical surface lines and no extra measurements would be taken for the soft boards / white boards / Glass.
79WALL PANELLING :- Fabricating and fixing wall/column paneling, the framing shallmade out of aluminium hollow section of 40mm x 37mm size1.5mm thick of JINDAL / INDAL at spacing not exceeding 600mm bothways (horizontal and vertical).Paneling framework to be secured to wall surface/column surface. Paneling framework to be clad on one side with 8mm thick ply finished with 1.0 mm thick Hoigh glossy premium laminate, all complete as per detailed drawing.
80Providing and Fixing full ht. filling storage made up of 19mm thick block board ,boxed from all side with 9mm plywood on back side resting on 100mm wide laminated recessed skirting of over all depth 385mm & ht.2135mm & with horizontal shelving in 19mm thick block board ,385 centre to cntre and vertical portion at 770 c/c laminated from inside with front coverage in 385mm wide single/double shutter in formed with flex as per specifications from inside exposed thickness in steam beach 4mm thick wooden margin wherever required, polished in natural sprit,finished with two coats of melamine complete in all respect including of concealed hinges magnets, brass handles, locks etc, all complete as per direction of SBSC/ Consultant.
81P/S Sofa with overall structure made in combination of S.S.25mm square pipe and in 12mm round pipe, seats and back in high density foam,full upholsteterd as per architects approval with basic dimension Depth = 30", back ht.= 29" seat ht.= 18" ,upholastry/fabric as per approved shade & pattern in following combination, all complete as per direction of SBSC/ Consultant. (B) Two Seater
82P/S Sofa with overall structure made in combination of S.S.25mm square pipe and in 12mm round pipe, seats and back in high density foam,full upholsteterd as per architects approval with basic dimension Depth = 30", back ht.= 29" seat ht.= 18" ,upholastry/fabric as per approved shade & pattern in following combination, all complete as per direction of SBSC/ Consultant. (B) Three Seater
83Supplying and placing side table whose glass shall be 10+/-0.3mm thick black tinted toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It shallbe a welded assembly made in SS202 grade having dia. 12+/-0.04 as per IS:1762.overall dimensions oftable shall be Width of table= 60.0 cm, Depth=60.0 cm, height=35.1 cm. , all complete as per direction of SBSC/ Consultant.
84Supplying & placing of Pre Assembled S.S. Magzine / Newspaper Stand size-( 1425 x400x 280 mm) colour & design as per approevd by SBSC/ Consultant.
85RE LAMINATION Re lamination of existing Furniture/Installations by taking out the old one and fixing 1.0 mm thick new laminate over 4.0 mm thick new commercial ply with fittings, polishing etc.complete.
86Renovation of Existing tables with new laminate, moulding, fittings, polishings etc. complete.
87Dismantling, Demolishing and Disposal of :- Wooden Partition
88Dismantling, Demolishing and Disposal of :- Fixed Almirah & Furnishing
89ELECTRICAL WORK
90SUB-HEAD - I: INTERNAL WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required, all complete as per direction of SBSC/ Consultant. Group -A
91Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required, all complete as per direction of SBSC/ Consultant. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
92Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required, all complete as per direction of SBSC/ Consultant. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
93Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required, all complete as per direction of SBSC/ Consultant. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
94Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required, all complete as per direction of SBSC/ Consultant 4 x 6 sq.mm + 2 x 6sq.mm. earth wire
95Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required, all complete as per direction of SBSC/ Consultant 4 x 10 sq.mm + 2 x 10sq.mm. earth wire
96Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required, all complete as per direction of SBSC/ Consultant 4 x 16 sq.mm + 2 x 16sq.mm. earth wire
97Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings), all complete as per direction of SBSC/ Consultant.
98Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required, all complete as per direction of SBSC/ Consultant.
99Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. , all complete as per direction of SBSC/ Consultant.
100Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required. , all complete as per direction of SBSC/ Consultant.
101Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. , all complete as per direction of SBSC/ Consultant. 20mm dia PVC conduit
102Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. , all complete as per direction of SBSC/ Consultant. 25mm dia PVC conduit
103Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. , all complete as per direction of SBSC/ Consultant. 32mm dia PVC conduit
104SUB-HEAD II - FANS & LIGHT FIXTURES:
105Supplying, fixing, connecting, testing and commissioning of 1 x 28 watt T-5 fluorescent luminaire complete with electronic ballast, lockable holders and fluorescent lamp including connection etc. as required , all complete as per direction of SBSC/ Consultant.
106Supply, installation, connecting, testing and commissioning of illuminated exit sign with 1 x 3 watt LED lamp including providing maintenance free batteries & charger capable of working for 2 hr duration mounted on ceiling/wall complete with the approved EXIT self adhesive labels as per site requirement as required , all complete as per direction of SBSC/ Consultant.
107Supplying of surface/ recessed type LED down-lighter with high efficiency white reflector and high transmissive diffuser ,fitting complete with, holder, electronic driver, heat sink and LED (less than 10% THD), low depth with die cast aluminium housing 1 x 34WLEDwith CRI >70, including with driver connections etc. as required , all complete as per direction of SBSC/ Consultant.
108Supply of Recess mounted LED 2"x2" luminaire delivering an initial system lumen of 3300 lumens & the luminaire shall be with system efficacy = 100 lm / W. Housing: CRCA, Rim: Engneering plastic / CRCA. Optics: polycarbonate/PMMA/Polysterene, IP20 Protection. The operating CCT shall be 5700K with CRI of =80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD = 10% & PF = 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. All complete as per direction of the SAIL/ Engineer/ Engineer"s Representative.
109Supplying of surface/recessed type LED down-lighter with high efficiency white reflector and high transmissive diffuser ,fitting complete with, holder,driver, heat sink and LED (less than 10% THD), low depth with die cast aluminium housing 1 x 15WLEDwith CRI >70, including with driver connections etc. as required , all complete as per direction of SBSC/ Consultant.
110Supplying, erection, connecting, testing and commissioning of wall bracket fan 400 mm sweep with step speed regulator complete as required. b) 400 mmsweep
111Supplying, erection, connecting, testing and commissioning of following size heavy duty exhaust fan complete with gravity louver and connection with 3 core flexible wire as required , all complete as per direction of SBSC/ Consultant. c) 200 mm dia fresh air fan - residential toilets & hostels
112Supplying, fixing, connecting, testing and commissioning of 1200mm sweep ceiling fan 5-star rate as per BEE complete with blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with face plate matching the existing modular switches as required , all complete as per direction of SBSC/ Consultant.
113Supplying, fixing, connecting, testing and commissioning of mirror light luminaire with 1 x 14 watt complete with electronicballast, lamp including connection etc. complete as required , all complete as per direction of SBSC/ Consultant.
114SUBHEAD- III: M.V. PANELS/ DISTRIBUTION BOARD
115Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB"s, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way Double door
116Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB"s, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way Double door
117Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB"s, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way Double door
118Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
119Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
120Supplying, installation,testing and commissioning ofcubical type MV Panelas per IEC:61439-I made out of 14 SWG sheet steel, totally enclosedIP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 100mmx50mmx5mm (thick), Fabrication shall be done intransportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switchgears.(Panelfor Library ) INCOMER:- 1 Nos.160 Amps. TPN MCCB (35 KA) with electronic releases. 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No. 0-160 Amp. Ammeter (digital type) with inbuilt ASS BUS BARS:- 200 Amps. TP&N aluminium bus bars (35 KA) OUT GOINGS:- 12 Nos. 63A TPN, MCB
121Supplying, installation,testing and commissioning ofcubical type MV Panelas per IEC:61439-I made out of 14 SWG sheet steel, totally enclosedIP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 100mmx50mmx5mm (thick), Fabrication shall be done intransportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switchgears. (Main UPS Panelfor Library ) INCOMER:- 1 Nos.63Amps. FP MCCB (25 KA) with electronic releases. 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No. 0-63 Amp. Ammeter (digital type) with inbuilt ASS BUS BARS:- 100 Amps. TP&N aluminium bus bars (35 KA) OUT GOINGS:- 12 Nos. 63A FP, MCB
122Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
123SUB-HEAD -IV : L.T. CABLES
124Supply, laying and testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 3.5 x 95 sq.mm
125Supply, laying and testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 3.5 x 50 sq.mm
126Supply, laying and testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 x 25 sq.mm
127Supply, laying and testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 x 16 sq.mm
128Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 95 sq.mm
129Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 50 sq.mm
130Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 25 sq.mm
131Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 16 sq.mm
132Supply, laying and testing of under noted sizes of Copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 x 25 sq.mm
133Supply, laying and testing of under noted sizes of Copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 x 16 sq.mm
134Supply, laying and testing of under noted sizes of Copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 x 10 sq.mm
135Supply, laying and testing of under noted sizes of Copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 x 4 sq.mm
136Supply and making end termination with brass double compression gland including providing and crimping of copper solderless lugs / ferrules for XLPE armoured power copper conductor cable 1.1 KV grade of following sizes:- 4 x 25 sq.mm
137Supply and making end termination with brass double compression gland including providing and crimping of copper solderless lugs / ferrules for XLPE armoured power copper conductor cable 1.1 KV grade of following sizes:- 4 x 16sq.mm
138Supply and making end termination with brass double compression gland including providing and crimping of copper solderless lugs / ferrules for XLPE armoured power copper conductor cable 1.1 KV grade of following sizes:- 4 x 10 sq.mm
139Supply and making end termination with brass double compression gland including providing and crimping of copper solderless lugs / ferrules for XLPE armoured power copper conductor cable 1.1 KV grade of following sizes:- 4 x 2.5 sq.mm
140Supply and fixingof cable tray/steel work in position including clamps, frame work of flats, angle iron, channel with fabrication work including cutting, bending, welding, drilling bolting etc. as per design as required.One coat of primer and 2 coats of enamel paint of approved shade shall be provided.
141Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
142SUB-HEAD -V : EARTHING
143Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
144Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
145Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
146Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
147Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
148Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
149Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
150Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
151SUB HEAD-VI : T.V. & TELEPHONE SYSTEM & CONDUITING FOR LAN SYSTEM
152Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair (8 core)
153Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair (4 core)
154Providing, laying connecting and testing of multi-core telephone armoured cable of conductor size 0.6 mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable as required 50 Pair telephone cable
155Providing, laying connecting and testing of multi-core telephone armoured cable of conductor size 0.6 mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable as required 20 Pair telephone cable
156Providing, laying connecting and testing of multi-core telephone armoured cable of conductor size 0.6 mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable as required 10 Pair telephone cable
157Providing, laying connecting and testing of multi-core telephone armoured cable of conductor size 0.6 mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable as required 5 Pair telephone cable
158Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 50 pair tag block
159Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 20 pair tag block
160Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 5 pair tag block
161Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm dia conduit pipe
162Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm dia conduit pipe
163Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm dia conduit pipe
164Providing, laying and fixing 80dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
165Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Supplying and fixing M.S. box with modular type telephone (RJ-11) outlet complete as required.
166Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. Supply and fixing of 75mm x 75mm x 60mm deep metal box on surface or in recess for RJ-45 outlets
167SUB-HEAD -VII : FIRE DETECTION SYSTEM
168Supply, installation, testing and commissioning of UL listed microprocessor based analog addressable intelligent fire alarm control panel (2 loops) complete with central processing unit.Network communication card RS-485 port, 8 lines, 21 character each (168 Characters total) graphic LCD display with primary power supply at 230 V 50 Hz AC provided with 24/36 volts,sealed maintenance free (SMF) batteries backup (as per IS) complete with solid state boost/trickle automatic battery charger. The panel shall have integral two way communication & voice evacuation facility address system with 8 channel zoned switch amplifier and auto voice dialing facility.The panel shall have UL listed field controlled from PC graphics software compatible to IBMS, security surveillance system , Public address system etc. as required.
169Supply, installation, testing and commissioning of UL listed integral microprocessor (not micro-controller) intelligent multi co-operative type addressable photoelectric or multi cooperative type optical smoke detectors based with moisture free & rust free in base complete as per specifications as required.
170Supply, installation, testing and commissioning of addressable type manual call point, 1 stage with in-built LED, lighting up automatically to confirm its actuation complete as per specification as required.
171Supply, installation, testing and commissioning of UL listed wall mounted hooter with strobe (100 dba) complete as per specification as required.
172Supply, installation, testing and commissioning of UL listedsurface type mounted directly on ceiling/ recessed 1/4-1/2 tap changer directional sounders with line matching transformer complete as per specification as required.
173Supplying, wiring, testing and commissioning of point wiring for speakers with 2 core 1.5 Sq.mm cu. shielded copper conductor wire including loop wiring from MFACP in M.S conduit with conduit accessories complete as required.
174Supplying, laying, testing and commissioning of point wiring for hooters with strobe circuits with 2 pair 1.5 sq.mm copper conductor flexible wire (1 pair shielded and 1 pair unshielded) including loop wiring from MFCP in M.S. conduit with conduit accessories complete as required.
175SUB-HEAD -VII : LAN SYSTEM
176Supply, installation, testing and commissioning of the following components as required. 4-pair, Cat6A UTP Cable, roll of 305m, 200 MHz, Blue Color(For Data)
177Supply, installation, testing and commissioning of the following components as required. 24-port unloaded Modular Jack Panel (for UTP Jacks only), 1U (For Data utp Field Cable)
178Supply, installation, testing and commissioning of the following components as required. Cat 6 Patch Cords - 7 Feet-Blue ( Data Work Station end)
179Supply, installation, testing and commissioning of the following components as required. Cat 6 Patch Cords - 4 Feet-Blue( Data Rack end)
180Supply, installation, testing and commissioning of the following components as required. 1-port British-style shuttered faceplate
181Supply, installation, testing and commissioning of the following components as required. Cat 6 UTP RJ-45 Jack with Strain relief and bend limiting boot Blue (For Data Rack & Workstation )
182Supply, installation, testing and commissioning of the following components as required. Cat 6 24-port loaded, 110 Connect Jack Panel, 1U (For Data UTP Cables) Closed rack
183Supply, installation, testing and commissioning of the following components as required. Cat 6 Patch Cords - 7 Feet-Yellow
184Supply, installation, testing and commissioning of the following components as required. Horizontal PVC cable manger
185Supply, installation, testing and commissioning of the following components as required. 6 U Wall Mount Rack
186Supply, installation, testing and commissioning of the following components as required. Hardware Pkt
187Supply, installation, testing and commissioning of the following components as required. Earthing Kit
188Supply, installation, testing and commissioning of the following components as required. AC Distribution Box (6 Points - 5A Sockets ) - IU
189SUB HEAD-IX: UPS SYSTEM
190Supply,installation, testing & commissioning of micro processor /DSP controlled20 KVA UPS in Parallelwith IGBT based rectifier to achieve THDI < 2% for linear load and < 3% for non linear load, with 15 mins backup, battery racks,circuit breaker, input power factor of greater than 0.99 at 100% loading, output power factor .8 and efficiency should be 92% minimum with True Online Double Conversion (VFI as per IEC 62040-3) UPS usingPWM IGBT technology on charger and inverter section, with galvanic isolation transformer connected at output end, Three Phase input and Three phaseoutput UPS system with networking Network Management Ethernet Card along-with software for SNMP / Web-based monitoring of UPS, Remote UPS Control, IBMS compatible, logging & reporting of UPS data and all interconnection cabling and as per specifications as required, all complete as per direction of SBSC/ Consultant.
191SUB HEAD : AIR CONDITIONING WORK
192HI WALL SPILT UNIT Providing, fixing, testing and commissioning high wall mounted spilt unit airconditioners with evaporator with fan with motor, cooling coil, filter, all enclosed in decorative plastic casing condenser with hermatically sealed rotary compressor, condenser coil, propeller fan with motor, inter connecting, refrigent piping, wiring, earthing, corded remote control, MS frame for mounting condensing unit
1932.0 Ton
1941.0 Ton
195Installation Charges
196Outdoor Stand
197Caging with Lock & Key facility
198Copper Piping
199Electrical cabling
200Drain piping - Hard PVC pipe (25 mm) with 12mm expanded polythene insulation
201SITC of 5 KVA stabilizer of reputed make
202SITC of 4 KVA stabilizer of reputed make
203Ceiling Mounted Cassette Unit Providing, fixing, testing and commissioning high ceiling mounted cassette unit airconditioners with evaporator with fan with motor, cooling coil, filter, all enclosed in decorative plastic casing condenser with hermatically sealed rotary compressor, condenser coil, propeller fan with motor, inter connecting, refrigent piping, wiring, earthing, corded remote control.
2043.0 Ton
205Installation Cost
206Outdoor Stand
207Caging with Lock & Key facility
208Copper Piping
209Electrical cabling
210Drain piping - Hard PVC pipe (25 mm) with 12mm expanded polythene insulation
211SITC of 6 KVA stabilizer of reputed make
Disclaimer :