Development Of Distribution Infrastructure At Central Zone Of Hpsebl Under Rdss (Mandi, Kullu, Hamirpur,Bilaspur Circle, Mandi-Himachal Pradesh

Himachal Pradesh State Electricity Board-HPSEB has published Development Of Distribution Infrastructure At Central Zone Of Hpsebl Under Rdss (Mandi, Kullu, Hamirpur,Bilaspur Circle. Submission Date for this Tender is 25-06-2024. Infrastructure Work Tenders in Mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42767372
Corrigendum : Development Of Distribution Infrastructure At Central Zone Of Hpsebl Under Rdss (Mandi, Kullu, Hamirpur,Bilaspur Circle
Open Tender
Indian
Himachal Pradesh
Mandi
25-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Development Of Distribution Infrastructure At Central Zone Of Hpsebl Under Rdss ( Mandi, Kullu, Hamirpur, Bilaspur Circle

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Mar-2024 Drawings Technical Bid 20-04-2024
2 11-Mar-2024 Technical Specifications Technical Bid 20-04-2024
3 11-Mar-2024 Addendum e-Reverse Auction Terms and Conditions 20-04-2024
4 18-Mar-2024 Corrigendum No.1 Terms and Conditions 20-04-2024
5 02-Apr-2024 List of Vendors Other 20-04-2024
6 19-Apr-2024 Key Date Corrigendum No. 1 Date 06-05-2024
7 08-May-2024 Key Date Corrigendum No. 2 Date 22-05-2024
8 25-May-2024 Key Date Corrigendum 3 Date 28-05-2024
9 27-May-2024 Key Date Corrigendum No. 4 Date 10-06-2024
10 12-Jun-2024 Corrigendum No.5 Date 25-06-2024

Key Value

Document Fees
INR 1475 /-
EMD
INR 50000000.0 /-
Tender Value
INR 561.66 Crore /-

Attachment

FileName File Description File Size
b9bf5569-d5aa-4184-bc6b-0c8e12cb8940.html Tender Notice 0 KB
BOQ_130912.xls Tender Document 0 KB
LatandLongofSubStations.pdf Tender Document 0 KB
MeteorologicalDataCZ.pdf Tender Document 0 KB
SBDPart1.pdf Tender Document 0 KB
SBDPart2.pdf Tender Document 0 KB
SBDPart3.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: -DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE AT Central ZONE OF HPSEBL UNDER RDSS (Mandi, kullu, Hamirpur,Bilaspur Circle)
Sl. No. Item Description
1AB Cablingworks ,33KV,22KV,11KV & LT Line overhead Line Ab Cabling & other Cabling Works as per technical specification, approved drawings and scope of work.
2LT AB Cable
3LT AB Cable on poles [Size: (3x95 Sq, mm ) +70sqmm (Insulated) +16 sqmm{Inclusive 3% sagging & wastage)
4LT AB Cable on poles [Size: (3x95 Sq, mm ) +70sqmm +16 sqmm{Inclusive 3% sagging & wastage)
5LT AB Cable on poles [Size: (3x95 Sq, mm ) +70sqmm (Insulated)+16 sqmm{Inclusive 3% sagging & wastage)
6LT AB Cable on poles [Size: (3x95 Sq, mm ) +70sqmm +16 sqmm{Inclusive 3% sagging & wastage)
7Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
8Muffs with concerete filling
9Stay Set Complete
10Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
11Full Clamp for stay
12Anchoring Assembly for LT
13Suspension Assembly for LT
14Facade Hooks for LT
15Distribution box 3 phase 5 connectors as per TS
16Piercing Connector as per TS
17Cable for SMDB 3.5Core X 35sqmm
18LT Earthing set complete (preferbly coil earthing)
19Red Oxide
20Aluminium paint
21LT ,ABCable3C x 185 + 1C x 150 (Insulated) + 1C x 16SqmmSq. mm {Inclusive 3% sagging & wastage)
22LT ABCable on poles [Size: (3x185mm²) x 1 Cables {Inclusive 3% sagging & wastage)
23Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
24Muffs with concerete filling
25Stay Set Complete
26Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
27Full Clamp for stay
28Anchoring Assembly for LT
29Suspension Assembly for LT
30Facade Hooks for LT
31Distribution box 3 phase 5 connectors as per TS
32Piercing Connector as per TS
33Cable for SMDB 3.5Core X 35sqmm
34LT Earthing set complete (preferbly coil earthing)
35Red Oxide
36Aluminium paint
37LT line with XLPE 3.5X185 mm²
38LT XLPE Cable on poles [Size: (3.5X185mm²) {additional 1% sagging & wastage)
39Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
40Muffs with concerete filling
41Stay Set Complete
42Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
43Full Clamp for stay
44X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
45Half Clamp for Cross Arm
46Anchoring Assembly for LT
47Suspension Assembly for LT
48Facade Hooks for LT
49T-Jointing kit
50LTEarthing set complete (preferbly coil earthing)
51Red Oxide
52Aluminium paint
53Providing underground LT Line with XLPE insulated PVC sheathed ArmouredUnderground 1x400sqmm (4+1)Total=2.5CKM
54Providing underground LT Line with PVC 1x400sqmm (4+1)
55Prov. Straight through joint
56Prov. Termination kit
57RCC cable cover
58Sand bag
59Route and joint indicating stone
60Inspection chamber
61GI pipe earthing 40 mmx 2.5/3 mm B class
62Pipe HDPE
63Lug Alm creamping suiitable for LT line with PVC 1x400sqmm
64GI flat 25x6
65Cleat HDPE for cable support
66GI pipe 100 mm dia
67Flat GI size 50x6
68Chanel 75x40
69Warning tape (printed PEUGutility protection)
70Providing underground LT Line with XLPE insulated PVC sheathed ArmouredUnderground 1x300sqmm (4+1)Total=2CKM
71Providing underground LT Line with PVC 1x300sqmm (4+1)
72Prov. Straight through joint
73Prov. Termination kit
74RCC cable cover
75Sand bag
76Route and joint indicating stone
77Inspection chamber
78GI pipe earthing 40 mmx 2.5/3 mm B class
79Pipe HDPE
80Lug Alm creamping suiitable for LT line with PVC 1x300sqmm
81GI flat 25x6
82Cleat HDPE for cable support
83GI pipe 100 mm dia
84Flat GI size 50x6
85Chanel 75x40
86Warning tape (printed PEUGutility protection)
87HT Cabling
8811kv HT AB Cable3x95+70 Sq. mm (Insulated) {Inclusive 3% sagging & wastage)
89HT ABCable on poles [Size: (3x95+70 (Insulated) Sq, mm ) {Inclusive 3% sagging & wastage)
90Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
91Muffs with concerete filling
92Stay Set Complete
93Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
94Full Clamp for stay
95X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
96Half Clamp for Cross Arm
97Anchoring Assembly for HT
98Suspension Assembly for HT
99Facade Hooks for HT
100Heat Shrinkable Straight Through Jointing Kit
101Cable Termination kit
102T-Jointing kit
103HT Earthing set complete (preferbly coil earthing)
104Red Oxide
105Aluminium paint
10622kv HT AB Cable3x95+70 Sq. mm (Insulated) {Inclusive 3% sagging & wastage)
107HT ABCable on poles [Size: (3x95+70 (Insulated) Sq, mm ) {Inclusive 3% sagging & wastage)
108Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
109Muffs with concerete filling
110Stay Set Complete
111Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
112Full Clamp for stay
113X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
114Half Clamp for Cross Arm
115Anchoring Assembly for HT
116Suspension Assembly for HT
117Facade Hooks for HT
118Heat Shrinkable Straight Through Jointing Kit
119Cable Termination kit
120T-Jointing kit
121HT Earthing set complete (preferbly coil earthing)
122Red Oxide
123Aluminium paint
12411kv HT AB Cable on poles [Size: (3x185 +150 Sqmm (Insulated) ) {Inclusive 3% sagging & wastage)
125HT AB Cable on poles [Size: (3x185 +150 Sqmm(Insulated) ) {Inclusive 3% sagging & wastage)
126Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
127Muffs with concerete filling
128Stay Set Complete
129Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
130Full Clamp for stay
131X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
132Half Clamp for Cross Arm
133Anchoring Assembly for HT
134Suspension Assembly for HT
135Facade Hooks for HT
136Heat Shrinkable Straight Through Jointing Kit
137Cable Termination kit
138T-Jointing kit
139HT Earthing set complete (preferbly coil earthing)
140Red Oxide
141Aluminium paint
14211kv HT AB Cable3x120+95 Sq. mm (Insulated) {Inclusive 3% sagging & wastage)
14311KV HT ABCable on poles [Size: (3x120 +95Sq, mm ) {Inclusive 3% sagging & wastage)
144Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
145Muffs with concerete filling
146Stay Set Complete
147Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
148Full Clamp for stay
149X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
150Half Clamp for Cross Arm
151Anchoring Assembly for HT
152Suspension Assembly for HT
153Facade Hooks for HT
154Heat Shrinkable Straight Through Jointing Kit
155Cable Termination kit
156T-Jointing kit
157HT Earthing set complete (preferbly coil earthing)
158Red Oxide
159Aluminium paint
16011kv HT XLPE Cable3x120 Sq. mm {Inclusive 3% sagging & wastage)
16111 kv HT XLPEarmoured Cable on poles [Size: (3x120 Sq, mm ) {Inclusive 3% sagging & wastage)
162Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
163Muffs with concerete filling
164Stay Set Complete
165Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
166Full Clamp for stay
167X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
168Half Clamp for Cross Arm
169Anchoring Assembly for HT
170Suspension Assembly for HT
171Facade Hooks for HT
172Heat Shrinkable Straight Through Jointing Kit
173Cable Termination kit
174T-Jointing kit
175HT Earthing set complete (preferbly coil earthing)
176Red Oxide
177Aluminium paint
178steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
179cable clamp made of GI sheet for 11kv 3x120 sq.mm
18011kv HT XLPE 3x240 sqmm XLPE(Armoured) Cable on poles [Size: (3x240 Sqmm ) {Inclusive 3% sagging & wastage)
18111 kV HT XLPE armoured Cableon poles [Size: 3x240 Sq. (mm²){Inclusive 3% sagging & wastage)
182Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
183Muffs with concerete filling
184Stay Set Complete
185Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
186Full Clamp for stay
187X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
188Half Clamp for Cross Arm
189Anchoring Assembly for HT
190Suspension Assembly for HT
191Facade Hooks for HT
192Heat Shrinkable Straight Through Jointing Kit
193Cable Termination kit
194T-Jointing kit
195HT Earthing set complete (preferbly coil earthing)
196Red Oxide
197Aluminium paint
198steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
199cable clamp made of GI sheet for 11kv 3x240 sq.mm
200Providing 11KV XLPE 1x240 sqmm (Armoured) total-5.6 ckm
201Providing 11KV XLPE 1x240 sqmm (3+1)
202Prov. Straight through joint
203Prov. Termination kit
204RCC cable cover
205Sand bag
206Route and joint indicating stone
207Inspection chamber
208GI pipe earthing 40 mmx 2.5/3 mm B class
209Pipe HDPE size 25 mm
210Lug Alm creamping 70 sqmm XLPE single hole
211GI flat 25x6
212Cleat HDPE for cable support
213GI pipe 100 mm dia
214Flat GI size 50x6
215Chanel 75x40
216Warning tape (printed PEUGutility protection)
217Cabling of 33kV line with 1x300 Sq. mm XLPE UG armoured Cable (3+1)(12CKM)
21833 kV XLPE Cable [Size:1x300mm²) {additional 1% wastage)]
21933 kV Cable Straight Through Jointing Kit [Size: 1x300 mm²]
22033 kV Cable Indoor Termination Kit [Size: 1x300 mm²]
22133 kV Cable Heat Shrink Outdoor Termination Kit [Size: 1x300mm²]
222RCC cable cover (2 feet Long)
223Sand Bag (50 Kg)
224Route and Joint indicating stone
225Inspection Chamber
226GI Pipe earthing 40 mm x 2.5/3 m "B" class
227Pipe HDPE of suitable size for 33KV XLPE 1X300 mm2
228Lug AL Crimping 70 SQMM XLPE Single HOLE
229Flat GI Size 25x6 mm
230Cleat HDPE for Cable Support
231G.I. Pipe 100 mm DIA "B" CLASS
232Flat GI Size 50x6 mm
233Channel MS Size 75x40 mm
234Wiring tape (Printed PE UG utility Protection)
235HVDS
236Conversion LT to HT
237LT to 11kv New Line on Steel Tubular Polewith Dog Conductor -100 Sq. mm
238ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
23911M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
240Muffs with concerete filling
241Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
242Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
243Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
24411 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
245Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
246X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
247X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
248Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
24911 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
250Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
251Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
252HT Earthing set complete (REC Constr. Stand. J-1)
253Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
254Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
255Eye Hook for earth wire
256Earth Wire Clamp
257MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
258Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
259Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
260Danger Plate
261Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
262Barbed Wire
263Red Oxide
264Aluminium Paint
265GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
266GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
267Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
268LT to22kv New Line on Steel Tubular Polewith Rabbit Conductor -50Sq. mm
269ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
27011M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
271Muffs with concerete filling
272Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
273Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
274Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
27522 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
276Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
277X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
278X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
279Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
28022 kV Pin Insulators (Porcelain, 24 kV, 10 kN): 3 No per double pole structure
281Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
282Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
283HT Earthing set complete (REC Constr. Stand. J-1)
284Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
285Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
286Eye Hook for earth wire
287Earth Wire Clamp
288MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
289Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
290Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
291Danger Plate
292Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
293Barbed Wire
294Red Oxide
295Aluminium Paint
296Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
297HVDS-New HT Line works as per Scope of Works
298New 22kv New Line on Steel Tubular Polewith Rabbit Conductor -50Sq. mm
299ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
30011M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
301Muffs with concerete filling
302Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
303Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
304Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
30522 kV Pin Insulators with GI Pin(Porcelain, 23 kV, 10 KN): 3 No per pole structure
306Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
307X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
308X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
309Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
31022 kV Pin Insulators (Porcelain, 24 kV, 10 kN): 3 No per double pole structure
311Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
312Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
313HT Earthing set complete (REC Constr. Stand. J-1)
314Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
315Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
316Eye Hook for earth wire
317Earth Wire Clamp
318MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
319Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
320Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
321Danger Plate
322Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
323Barbed Wire
324Red Oxide
325Aluminium Paint
326GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
327GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
32811kv New Line on Steel Tubular Polewith Dog Conductor -100 Sq. mm
329ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
33011M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
331Muffs with concerete filling
332Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
333Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
334Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
33511 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
336Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
337X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
338X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
339Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
34011 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
341Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
342Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
343HT Earthing set complete (REC Constr. Stand. J-1)
344Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
345Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
346Eye Hook for earth wire
347Earth Wire Clamp
348MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
349Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
350Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
351Danger Plate
352Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
353Barbed Wire
354Red Oxide
355Aluminium Paint
356GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
357GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
35811kv New Line on Steel Tubular Polewith Rabbit Conductor -50Sq. mm
359ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
36011M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
361Muffs with concerete filling
362Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
363Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
364Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
36511 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
366Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
367X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
368X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
369Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
37011 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
371Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
372Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
373HT Earthing set complete (REC Constr. Stand. J-1)
374Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
375Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
376Eye Hook for earth wire
377Earth Wire Clamp
378MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
379Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
380Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
381Danger Plate
382Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
383Barbed Wire
384Red Oxide
385Aluminium Paint
386GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
387GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
38811kv HT XLPE Cable3x120 Sq. mm {Inclusive 3% sagging & wastage)
38911 kv HT XLPEarmoured Cable on poles [Size: (3x120 Sq, mm ) {Inclusive 3% sagging & wastage)
390Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
391Muffs with concerete filling
392Stay Set Complete
393Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
394Full Clamp for stay
395X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
396Half Clamp for Cross Arm
397Anchoring Assembly for HT
398Suspension Assembly for HT
399Facade Hooks for HT
400Heat Shrinkable Straight Through Jointing Kit
401Cable Termination kit
402T-Jointing kit
403HT Earthing set complete (preferbly coil earthing)
404Red Oxide
405Aluminium paint
406steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
407cable clamp made of GI sheet for 11kv 3x120 sq.mm
40822kv HT XLPE Cable3x120 Sq. mm {Inclusive 3% sagging & wastage)
40922 kv HT XLPEarmoured Cable on poles [Size: (3x120 Sq, mm ) {Inclusive 3% sagging & wastage)
410Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
411Muffs with concerete filling
412Stay Set Complete
413Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
414Full Clamp for stay
415X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
416Half Clamp for Cross Arm
417Anchoring Assembly for HT
418Suspension Assembly for HT
419Facade Hooks for HT
420Heat Shrinkable Straight Through Jointing Kit
421Cable Termination kit
422T-Jointing kit
423HT Earthing set complete (preferbly coil earthing)
424Red Oxide
425Aluminium paint
426steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
427cable clamp made of GI sheet for 11kv 3x120 sq.mm
428Supply ,Installation and commissioning of New DT as per scope of work
429Distribution Transformer 25 kva , 11/.440v
430Distribution Transformer (Ordinary), 11/0.4 kV,25 KVA
431Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
432Muffs with concerete filling
433X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
434MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA"s
435X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
436X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
437X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
438MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
439MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
440MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
441MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
442MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
443GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
444GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
445D.O Fuse Unit 11KV
446Lightening Arrester, 9 kV Station Class(Porcelain Type)
447Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
448Stay set complete (HT)
449Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
450Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
451LT Distribution Panel Box with MCCB(50A, 25 kA, 4P),O/G Kit Kit 63A 4Nos
452Half Clamp (M.S. Flat 50X6 mm)
453Full Clamps (M.S. Flat 50X6 mm)
454Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
455Aluminium Thimble
456Aluminium Thimble
457Danger Plate
458Barbed Wire
459LT Cable (3.5 Core) 50 mm²
460Red Oxide
461Aluminium Paint
462LT Switched Capacitors 4- KVAr for 25 KVA(rate per KVAr)
463Distribution Transformer 63 kva , 11/.440v
464Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA
465Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
466Muffs with concerete filling
467X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
468MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
469X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
470X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
471X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
472MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
473MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
474MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
475MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
476MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
477GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
478GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
479D.O Fuse Unit 11KV
480Lightening Arrester, 9 kV Station Class(Porcelain Type)
481Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
482Stay set complete (HT)
483Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
484Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
485LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(63A, 4No, rewirable)
486Half Clamp (M.S. Flat 50X6 mm)
487Full Clamps (M.S. Flat 50X6 mm)
488Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
489Aluminium Thimble
490Aluminium Thimble
491Danger Plate
492Barbed Wire
493LT Cable (3.5 Core)120mm²
494Red oxide
495Aluminium Paint
496LT Switched Capacitors 8- KVAr for 63KVA(rate per KVAr)
497Distribution Transformer 100 KVA
498Distribution Transformer (Ordinary), 11/0.4 kV,100 KVA
499Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
500Muffs with concerete filling
501X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
502MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
503X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
504X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
505X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
506MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
507MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
508MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
509MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
510MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
511GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
512GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
513D.O Fuse Unit 11KV
514Lightening Arrester, 9 kV Station Class(Porcelain Type)
515Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
516Stay set complete
517Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
518Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
519LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
520Half Clamp (M.S. Flat 50X6 mm)
521Full Clamps (M.S. Flat 50X6 mm)
522Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
523Aluminium Thimble
524Aluminium Thimble
525Danger Plate
526Barbed Wire
527LT Cable (3.5 Core) 185 mm²
528Red Oxide
529Aluminium Paint
530LT Switched Capacitors 12- KVAr for 100 KVA(rate per KVAr)
531Distribution Transformer 25 kva , 22/.440KV
532Distribution Transformer (Ordinary), 22/0.4 kV,25 KVA
533Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
534Muffs with concerete filling
535X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
536MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA"s
537X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
538X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
539X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
540MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
541MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
542MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
543MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
544MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
545GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
546GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
547D.O Fuse Unit 22KV
548Lightening Arrester, 18 kV Station Class(Porcelain Type)
549Discs insulator sets (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
550Stay set complete (HT)
551Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
552Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
553LT Distribution Panel Box with MCCB(50A, 25 kA, 4P),O/G Kit Kit 63A 4Nos
554Half Clamp (M.S. Flat 50X6 mm)
555Full Clamps (M.S. Flat 50X6 mm)
556Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
557Aluminium Thimble
558Aluminium Thimble
559Danger Plate
560Barbed Wire
561LT Cable (3.5 Core) 50 mm²
562Red Oxide
563Aluminium Paint
564LT Switched Capacitors 4- KVAr for 25 KVA(rate per KVAr)
565Distribution Transformer 63 kva , 22/.440Kv
566Distribution Transformer (Ordinary), 22/0.4 kV,63 KVA
567Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
568Muffs with concerete filling
569X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
570MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
571X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
572X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
573X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
574MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
575MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
576MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
577MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
578MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
579GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
580GO AB Switch Unit (22 kV, 400A, 25 KA ) Tripple pole O/D type
581D.O Fuse Unit 22KV
582Lightening Arrester, 9 kV Station Class(Porcelain Type)
583Discs insulator sets (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
584Stay set complete (HT)
585Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
586Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
587LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(63A, 4No, rewirable)
588Half Clamp (M.S. Flat 50X6 mm)
589Full Clamps (M.S. Flat 50X6 mm)
590Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
591Aluminium Thimble
592Aluminium Thimble
593Danger Plate
594Barbed Wire
595LT Cable (3.5 Core)120mm²
596Red oxide
597Aluminium Paint
598LT Switched Capacitors 8- KVAr for 63KVA(rate per KVAr)
599Distribution Transformer 100 KVA (22KV)
600Distribution Transformer (Ordinary), 22/0.4 kV,100 KVA
601Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
602Muffs with concerete filling
603X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
604MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
605X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
606X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
607X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
608MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
609MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
610MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
611MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
612MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
613GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
614GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
615D.O Fuse Unit 22KV
616Lightening Arrester, 9 kV Station Class(Porcelain Type)
617Discs insulator sets (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
618Stay set complete
619Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
620Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
621LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
622Half Clamp (M.S. Flat 50X6 mm)
623Full Clamps (M.S. Flat 50X6 mm)
624Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
625Aluminium Thimble
626Aluminium Thimble
627Danger Plate
628Barbed Wire
629LT Cable (3.5 Core) 185 mm²
630Red Oxide
631Aluminium Paint
632LT Switched Capacitors 12- KVAr for 100 KVA(rate per KVAr)
633Conversion to LT Line toAB Cable
634Conversion of bare conductor with 3x70 Sq. mmAB cable
635LT ABCable on poles [Size: : 3x70mm²) + 50 sqmm(Insulated)+16sqmm x 1 Cables {Inclusive 3% sagging & wastage)
636Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
637Muffs with concerete filling
638Stay Set Complete
639Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
640Full Clamp for stay
641Anchoring Assembly for LT
642Suspension Assembly for LT
643Facade Hooks for LT
644Distribution box 3 phase 5 connectors as per TS
645Piercing Connector as per TS
646Cable for SMDB 3.5Core X 35sqmm
647T-Jointing kit
648LT Earthing set complete (preferbly coil earthing)
649Red Oxide
650Aluminium paint
651Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
652Conversion ofLT Line with ABCable3C x 185 + 1C x 150 (Insulated) + 1C x 16SqmmSq. mm {Inclusive 3% sagging & wastage)
653LT ABCable on poles [Size: (3x185mm²) x 1 Cables {Inclusive 3% sagging & wastage)
654Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
655Muffs with concerete filling
656Stay Set Complete
657Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
658Full Clamp for stay
659Anchoring Assembly for LT
660Suspension Assembly for LT
661Facade Hooks for LT
662Distribution box 3 phase 5 connectors as per TS
663Piercing Connector as per TS
664Cable for SMDB 3.5Core X 35sqmm
665LT Earthing set complete (preferbly coil earthing)
666Red Oxide
667Aluminium paint
668Feeder Bifurcation Works
669Feeder Bifurcation Works-New HT Lines
670New 22kv New Line on Steel Tubular Polewith Dog Conductor -100Sq. mm
671ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
67211M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
673Muffs with concerete filling
674Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
675Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
676Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
67722 kV Pin Insulators with GI Pin(Porcelain, 23 kV, 10 KN): 3 No per pole structure
678Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
679X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
680X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
681Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
68222 kV Pin Insulators (Porcelain, 24 kV, 10 kN): 3 No per double pole structure
683Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
684Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
685HT Earthing set complete (REC Constr. Stand. J-1)
686Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
687Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
688Eye Hook for earth wire
689Earth Wire Clamp
690MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
691Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
692Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
693Danger Plate
694Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
695Barbed Wire
696Red Oxide
697Aluminium Paint
698GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
699GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
70011kv New Line on Steel Tubular Polewith Dog Conductor -100 Sq. mm
701ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
70211M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
703Muffs with concerete filling
704Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
705Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
706Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
70711 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
708Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
709X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
710X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
711Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
71211 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
713Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
714Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
715HT Earthing set complete (REC Constr. Stand. J-1)
716Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
717Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
718Eye Hook for earth wire
719Earth Wire Clamp
720MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
721Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
722Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
723Danger Plate
724Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
725Barbed Wire
726Red Oxide
727Aluminium Paint
728GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
729GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
73011kv New Line on Steel Tubular Polewith Rabbit Conductor -50Sq. mm
731ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
73211M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
733Muffs with concerete filling
734Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
735Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
736Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
73711 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
738Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
739X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
740X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
741Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
74211 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
743Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
744Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
745HT Earthing set complete (REC Constr. Stand. J-1)
746Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
747Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
748Eye Hook for earth wire
749Earth Wire Clamp
750MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
751Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
752Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
753Danger Plate
754Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
755Barbed Wire
756Red Oxide
757Aluminium Paint
758GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
759GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
76011kv HT XLPE Cable3x120 Sq. mm {Inclusive 3% sagging & wastage)
76111kv HT XLPE Cable on poles [Size: (3x120 Sq, mm ) {Inclusive 3% sagging & wastage)
762Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
763Muffs with concerete filling
764Stay Set Complete
765Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
766Full Clamp for stay
767X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
768Half Clamp for Cross Arm
769Anchoring Assembly for HT
770Suspension Assembly for HT
771Facade Hooks for HT
772Heat Shrinkable Straight Through Jointing Kit
773Cable Termination kit
774T-Jointing kit
775HT Earthing set complete (preferbly coil earthing)
776Red Oxide
777Aluminium paint
778steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
779cable clamp made of GI sheet for 11kv 3x120 sq.mm
780Feeder Bifurcation Works-DT
781Supply ,Installation and commissioning of New DT as per scope of work
782Distribution Transformer 25 kva , 11/.440v
783Distribution Transformer (Ordinary), 11/0.4 kV,25 KVA
784Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
785Muffs with concerete filling
786X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
787MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA"s
788X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
789X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
790X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
791MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
792MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
793MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
794MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
795MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
796GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
797GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
798D.O Fuse Unit 11KV
799Lightening Arrester, 9 kV Station Class(Porcelain Type)
800Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 11 kV, 90 kN) including Dead End Clamps etc.)
801Stay set complete (HT)
802Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
803Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
804LT Distribution Panel Box with MCCB(50A, 25 kA, 4P),O/G Kit Kit 63A 4Nos
805Half Clamp (M.S. Flat 50X6 mm)
806Full Clamps (M.S. Flat 50X6 mm)
807Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
808Aluminium Thimble
809Aluminium Thimble
810Danger Plate
811Barbed Wire
812LT Cable (3.5 Core) 50 mm²
813Red Oxide
814Aluminium Paint
815LT Switched Capacitors 4- KVAr for 25 KVA(rate per KVAr)
816Distribution Transformer 63 kva , 11/.440v
817Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA
818Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
819Muffs with concerete filling
820X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
821MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
822X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
823X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
824X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
825MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
826MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
827MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
828MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
829MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
830GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
831GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
832D.O Fuse Unit 11KV
833Lightening Arrester, 9 kV Station Class(Porcelain Type)
834Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
835Stay set complete (HT)
836Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
837Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
838LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(63A, 4No, rewirable)
839Half Clamp (M.S. Flat 50X6 mm)
840Full Clamps (M.S. Flat 50X6 mm)
841Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
842Aluminium Thimble
843Aluminium Thimble
844Danger Plate
845Barbed Wire
846LT Cable (3.5 Core)120mm²
847Red oxide
848Aluminium Paint
849LT Switched Capacitors 8- KVAr for 63KVA(rate per KVAr)
850Distribution Transformer 100 KVA
851Distribution Transformer (Ordinary), 11/0.4 kV,100 KVA
852Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
853Muffs with concerete filling
854X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
855MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
856X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
857X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
858X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
859MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
860MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
861MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
862MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
863MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
864GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
865GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
866D.O Fuse Unit 11KV
867Lightening Arrester, 9 kV Station Class(Porcelain Type)
868Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
869Stay set complete
870Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
871Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
872LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
873Half Clamp (M.S. Flat 50X6 mm)
874Full Clamps (M.S. Flat 50X6 mm)
875Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
876Aluminium Thimble
877Aluminium Thimble
878Danger Plate
879Barbed Wire
880LT Cable (3.5 Core) 185 mm²
881Red Oxide
882Aluminium Paint
883LT Switched Capacitors 12- KVAr for 100 KVA(rate per KVAr)
884Distribution Transformer 250 KVA
885Distribution Transformer (Ordinary), 11/0.4 kV,250 KVA
886Steel Tubular Poles (10 m, Working Load > 300 kgf/m²)
887Muffs with concerete filling
888X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
889MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
890X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
891X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
892X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
893MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
894MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
895MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
896MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
897MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
898GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
899GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
900D.O Fuse Unit 11KV
901Lightening Arrester, 9 kV Station Class(Porcelain Type)
902Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
903Stay set complete
904Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
905Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
906LT Distribution Panel Box with MCCB(400A, 50kA, 4P) and SFU(150A, 4No MCCB)
907Half Clamp (M.S. Flat 50X6 mm)
908Full Clamps (M.S. Flat 50X6 mm)
909Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
910Aluminium Thimble
911Aluminium Thimble
912Danger Plate
913Barbed Wire
914LT Cable (3.5 Core) 300 mm²
915Red Oxide
916Aluminium Paint
917LT Switched Capacitors 36- KVAr for 250 KVA(rate per KVAr)
918Transformer Bed( Civil Work (As Per HPSR))
919Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
920Distribution Transformer 63 kva , 22/.4kv
921Distribution Transformer (Ordinary), 22/0.4 kV,63 KVA
922Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
923Muffs with concerete filling
924X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
925MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA"s
926X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
927X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
928X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
929MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
930MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
931MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
932MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
933MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
934GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
935GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
936D.O Fuse Unit 22KV
937Lightening Arrester, 18 kV Station Class(Porcelain Type)
938Discs insulator sets (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
939Stay set complete (HT)
940Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
941Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
942LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(32A, 4No, rewirable)
943Half Clamp (M.S. Flat 50X6 mm)
944Full Clamps (M.S. Flat 50X6 mm)
945Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
946Aluminium Thimble
947Aluminium Thimble
948Danger Plate
949Barbed Wire
950LT Cable (3.5 Core) 120 mm²
951Red Oxide
952Aluminium Paint
953LT Switched Capacitors 8- KVAr for 63 KVA(rate per KVAr)
954Distribution Transformer 100 KVA (22KV)
955Distribution Transformer (Ordinary), 22/0.4 kV,100 KVA
956Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
957Muffs with concerete filling
958X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
959MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
960X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
961X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
962X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
963MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
964MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
965MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
966MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
967MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
968GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
969GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
970D.O Fuse Unit 22KV
971Lightening Arrester, 22 kV Station Class(Porcelain Type)
972Discs insulator sets (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
973Stay set complete
974Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
975Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
976LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
977Half Clamp (M.S. Flat 50X6 mm)
978Full Clamps (M.S. Flat 50X6 mm)
979Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
980Aluminium Thimble
981Aluminium Thimble
982Danger Plate
983Barbed Wire
984LT Cable (3.5 Core) 185 mm²
985Red Oxide
986Aluminium Paint
987LT Switched Capacitors 12- KVAr for 100 KVA(rate per KVAr)
988Feeder Bifurcation-New LT Lines
989New LT Line -single phase two wireon rabbit conductor -50 Sq. mm
990ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
991Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
992Muffs with concerete filling
993Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
994Shackle Insulator (16 kN)
995D-Iron (U- Clamps)
996Earth Knob
997LT Stay Set Complete
998Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
999Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1000Earthing Set complete
1001Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1002Spool Tie
1003Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1004Aluminium Paint
1005Red Oxide
1006New LT Line -Three phase four wireon rabbit conductor -50 Sq. mm
1007ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
1008Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1009Muffs with concerete filling
1010Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1011Shackle Insulator (16 kN)
1012D-Iron (U- Clamps)
1013Earth Knob
1014LT Stay Set
1015Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1016Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1017Earthing Set complete
1018Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1019Spool Tie
1020Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1021Aluminium Paint
1022Red Oxide
1023Spiral PVC Spacer
1024Feeder Segeration-New HT Lines
102511kv New Line on Steel Tubular Polewith Dog Conductor -100 Sq. mm
1026ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
102711M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1028Muffs with concerete filling
1029Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
1030Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
1031Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
103211 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
1033Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1034X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1035X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1036Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
103711 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
1038Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1039Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1040HT Earthing set complete (REC Constr. Stand. J-1)
1041Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
1042Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
1043Eye Hook for earth wire
1044Earth Wire Clamp
1045MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
1046Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1047Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1048Danger Plate
1049Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1050Barbed Wire
1051Red Oxide
1052Aluminium Paint
1053GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
1054GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1055New 22kv New Line on Steel Tubular Polewith Rabbit Conductor -50Sq. mm
1056ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
105711M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1058Muffs with concerete filling
1059Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
1060Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
1061Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
106222 kV Pin Insulators with GI Pin(Porcelain, 23 kV, 10 KN): 3 No per pole structure
1063Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1064X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1065X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1066Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
106722 kV Pin Insulators (Porcelain, 24 kV, 10 kN): 3 No per double pole structure
1068Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1069Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1070HT Earthing set complete (REC Constr. Stand. J-1)
1071Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
1072Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
1073Eye Hook for earth wire
1074Earth Wire Clamp
1075MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
1076Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1077Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1078Danger Plate
1079Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1080Barbed Wire
1081Red Oxide
1082Aluminium Paint
1083GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
1084GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
108511kv HT XLPE Cable3x120 Sq. mm {Inclusive 3% sagging & wastage)
108611kv HT XLPE Cable on poles [Size: (3x120 Sq, mm ) {Inclusive 3% sagging & wastage)
1087Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1088Muffs with concerete filling
1089Stay Set Complete
1090Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1091Full Clamp for stay
1092X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
1093Half Clamp for Cross Arm
1094Anchoring Assembly for HT
1095Suspension Assembly for HT
1096Facade Hooks for HT
1097Heat Shrinkable Straight Through Jointing Kit
1098Cable Termination kit
1099T-Jointing kit
1100HT Earthing set complete (preferbly coil earthing)
1101Red Oxide
1102Aluminium paint
1103steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
1104cable clamp made of GI sheet for 11kv 3x120 sq.mm
110522kv HT XLPE Cable3x120 Sq. mm {Inclusive 3% sagging & wastage)
110622kv HT XLPE Cable on poles [Size: (3x120 Sq, mm ) {Inclusive 3% sagging & wastage)
1107Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1108Muffs with concerete filling
1109Stay Set Complete
1110Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1111Full Clamp for stay
1112X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
1113Half Clamp for Cross Arm
1114Anchoring Assembly for HT
1115Suspension Assembly for HT
1116Facade Hooks for HT
1117Heat Shrinkable Straight Through Jointing Kit
1118Cable Termination kit
1119T-Jointing kit
1120HT Earthing set complete (preferbly coil earthing)
1121Red Oxide
1122Aluminium paint
1123steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
1124cable clamp made of GI sheet for 11kv 3x120 sq.mm
1125Feeder Segeration Works-DT
1126Supply ,Installation and commissioning of New DT as per scope of work
1127Distribution Transformer 63 kva , 11/.440v
1128Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA
1129Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1130Muffs with concerete filling
1131X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
1132MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
1133X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1134X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1135X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1136MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1137MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1138MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1139MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1140MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1141GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
1142GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1143D.O Fuse Unit 11KV
1144Lightening Arrester, 9 kV Station Class(Porcelain Type)
1145Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
1146Stay set complete (HT)
1147Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1148Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1149LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(63A, 4No, rewirable)
1150Half Clamp (M.S. Flat 50X6 mm)
1151Full Clamps (M.S. Flat 50X6 mm)
1152Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1153Aluminium Thimble
1154Aluminium Thimble
1155Danger Plate
1156Barbed Wire
1157LT Cable (3.5 Core)120mm²
1158Red oxide
1159Aluminium Paint
1160LT Switched Capacitors 8- KVAr for 63KVA(rate per KVAr)
1161Feeder Segeration-New LT Lines
1162LT AB Cable on poles [Size: (3x95+70 (Insulated) +16 (insulated) Sqmm ) {Inclusive 3% sagging & wastage)
1163LT AB Cable on poles [Size: (3x95 Sq, mm ) +70sqmm (Insulated)+16 sqmm{Inclusive 3% sagging & wastage)
1164Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1165Muffs with concerete filling
1166Stay Set Complete
1167Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1168Full Clamp for stay
1169Anchoring Assembly for LT
1170Suspension Assembly for LT
1171Facade Hooks for LT
1172Distribution box 3 phase 5 connectors as per TS
1173Piercing Connector as per TS
1174Cable for SMDB 3.5Core X 35sqmm
1175LT Earthing set complete (preferbly coil earthing)
1176Red Oxide
1177Aluminium paint
1178New LT Line -single phase two wireon rabbit conductor -50 Sq. mm
1179ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
1180Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1181Muffs with concerete filling
1182Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1183Shackle Insulator (16 kN)
1184D-Iron (U- Clamps)
1185Earth Knob
1186LT Stay Set Complete
1187Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1188Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1189Earthing Set complete
1190Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1191Spool Tie
1192Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1193Aluminium Paint
1194Red Oxide
1195New LT Line -Three phase four wireon rabbit conductor -50 Sq. mm
1196ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
1197Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1198Muffs with concerete filling
1199Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1200Shackle Insulator (16 kN)
1201D-Iron (U- Clamps)
1202Earth Knob
1203LT Stay Set
1204Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1205Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1206Earthing Set complete
1207Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1208Spool Tie
1209Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1210Aluminium Paint
1211Red Oxide
1212Spiral PVC Spacer
1213NEW HT Lines
1214New 22kv New Line on Steel Tubular Polewith Dog Conductor -100Sq. mm
1215ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
121611M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1217Muffs with concerete filling
1218Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
1219Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
1220Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
122122 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
1222Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1223X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1224X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1225Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
122622 kV Pin Insulators (Porcelain, 24 kV, 10 kN): 3 No per double pole structure
1227Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1228Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1229HT Earthing set complete (REC Constr. Stand. J-1)
1230Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
1231Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
1232Eye Hook for earth wire
1233Earth Wire Clamp
1234MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
1235Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1236Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1237Danger Plate
1238Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1239Barbed Wire
1240Red Oxide
1241Aluminium Paint
1242GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
1243GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
124411kv New Line on Steel Tubular Polewith Dog Conductor -100 Sq. mm
1245ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
124611M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1247Muffs with concerete filling
1248Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
1249Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
1250Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
125111 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
1252Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1253X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1254X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1255Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
125611 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
1257Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1258Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1259HT Earthing set complete (REC Constr. Stand. J-1)
1260Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
1261Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
1262Eye Hook for earth wire
1263Earth Wire Clamp
1264MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
1265Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1266Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1267Danger Plate
1268Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1269Barbed Wire
1270Red Oxide
1271Aluminium Paint
1272GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
1273GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
127411kv New Line on Steel Tubular Polewith Rabbit Conductor -50Sq. mm
1275ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
127611M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1277Muffs with concerete filling
1278Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
1279Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
1280Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
128111 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
1282Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1283X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1284X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1285Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
128611 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
1287Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1288Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1289HT Earthing set complete (REC Constr. Stand. J-1)
1290Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
1291Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
1292Eye Hook for earth wire
1293Earth Wire Clamp
1294MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
1295Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1296Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1297Danger Plate
1298Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1299Barbed Wire
1300Red Oxide
1301Aluminium Paint
1302GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
1303GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1304NEW LT Lines (on New DTRs)
1305New LT Line -single phase two wireon rabbit conductor -50 Sq. mm
1306ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
1307Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1308Muffs with concerete filling
1309Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1310Shackle Insulator (16 kN)
1311D-Iron (U- Clamps)
1312Earth Knob
1313LT Stay Set Complete
1314Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1315Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1316Earthing Set complete
1317Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1318Spool Tie
1319Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1320Aluminium Paint
1321Red Oxide
1322New LT Line -Three phase four wireon rabbit conductor -50 Sq. mm
1323ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
1324Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1325Muffs with concerete filling
1326Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1327Shackle Insulator (16 kN)
1328D-Iron (U- Clamps)
1329Earth Knob
1330LT Stay Set
1331Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1332Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1333Earthing Set complete
1334Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1335Spool Tie
1336Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1337Aluminium Paint
1338Red Oxide
1339Spiral PVC Spacer
1340New LT Line -Three phase four wireon Dog conductor -100 Sq. mm
1341ACSR 6/1/4.72 {Includes 4 conductor lengths for 3F, 4 wire and Inclusive 3% (Sag, Jumpering and wastage}
1342Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1343Muffs with concerete filling
1344Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1345Shackle Insulator (16 kN)
1346D-Iron (U- Clamps)
1347Earth Knob
1348LT Stay Set
1349Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1350Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1351Earthing Set complete
1352Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1353Spool Tie
1354Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1355Aluminium Paint
1356Red Oxide
1357Spiral PVC Spacer
1358New DT
1359Supply ,Installation and commissioning of New DT as per scope of work
1360Distribution Transformer 25 kva , 11/.440v
1361Distribution Transformer (Ordinary), 11/0.4 kV,25 KVA
1362Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1363Muffs with concerete filling
1364X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
1365MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA"s
1366X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1367X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1368X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1369MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1370MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1371MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1372MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1373MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1374GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
1375GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1376D.O Fuse Unit 11KV
1377Lightening Arrester, 9 kV Station Class(Porcelain Type)
1378Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 11 kV, 90 kN) including Dead End Clamps etc.)
1379Stay set complete (HT)
1380Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1381Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1382LT Distribution Panel Box with MCCB(50A, 25 kA, 4P),O/G Kit Kit 63A 4Nos
1383Half Clamp (M.S. Flat 50X6 mm)
1384Full Clamps (M.S. Flat 50X6 mm)
1385Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1386Aluminium Thimble
1387Aluminium Thimble
1388Danger Plate
1389Barbed Wire
1390LT Cable (3.5 Core) 50 mm²
1391Red Oxide
1392Aluminium Paint
1393LT Switched Capacitors 4- KVAr for 25 KVA(rate per KVAr)
1394Distribution Transformer 63 kva , 11/.440v
1395Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA
1396Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1397Muffs with concerete filling
1398X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
1399MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
1400X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1401X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1402X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1403MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1404MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1405MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1406MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1407MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1408GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
1409GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1410D.O Fuse Unit 11KV
1411Lightening Arrester, 9 kV Station Class(Porcelain Type)
1412Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
1413Stay set complete (HT)
1414Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1415Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1416LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(63A, 4No, rewirable)
1417Half Clamp (M.S. Flat 50X6 mm)
1418Full Clamps (M.S. Flat 50X6 mm)
1419Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1420Aluminium Thimble
1421Aluminium Thimble
1422Danger Plate
1423Barbed Wire
1424LT Cable (3.5 Core)120mm²
1425Red oxide
1426Aluminium Paint
1427LT Switched Capacitors 8- KVAr for 63KVA(rate per KVAr)
1428Distribution Transformer 100 KVA
1429Distribution Transformer (Ordinary), 11/0.4 kV,100 KVA
1430Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1431Muffs with concerete filling
1432X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
1433MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
1434X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1435X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1436X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1437MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1438MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1439MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1440MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1441MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1442GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
1443GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1444D.O Fuse Unit 11KV
1445Lightening Arrester, 9 kV Station Class(Porcelain Type)
1446Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
1447Stay set complete
1448Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1449Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1450LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
1451Half Clamp (M.S. Flat 50X6 mm)
1452Full Clamps (M.S. Flat 50X6 mm)
1453Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1454Aluminium Thimble
1455Aluminium Thimble
1456Danger Plate
1457Barbed Wire
1458LT Cable (3.5 Core) 185 mm²
1459Red Oxide
1460Aluminium Paint
1461LT Switched Capacitors 12- KVAr for 100 KVA(rate per KVAr)
1462Distribution Transformer 250 KVA
1463Distribution Transformer (Ordinary), 11/0.4 kV,250 KVA
1464Steel Tubular Poles (10 m, Working Load > 300 kgf/m²)
1465Muffs with concerete filling
1466X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
1467MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
1468X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1469X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1470X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1471MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1472MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1473MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1474MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1475MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1476GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
1477GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1478D.O Fuse Unit 11KV
1479Lightening Arrester, 9 kV Station Class(Porcelain Type)
1480Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
1481Stay set complete
1482Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1483Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1484LT Distribution Panel Box with MCCB(400A, 50kA, 4P) and SFU(150A, 4No MCCB)
1485Half Clamp (M.S. Flat 50X6 mm)
1486Full Clamps (M.S. Flat 50X6 mm)
1487Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1488Aluminium Thimble
1489Aluminium Thimble
1490Danger Plate
1491Barbed Wire
1492LT Cable (3.5 Core) 300 mm²
1493Transformer Bed( Civil Work (As Per HPSR))
1494Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
1495Red Oxide
1496Aluminium Paint
1497LT Switched Capacitors 36- KVAr for 250 KVA(rate per KVAr)
1498Distribution Transformer 400 KVA
1499Distribution Transformer (Ordinary), 11/0.4 kV,400 KVA
1500Steel Tubular Poles (10 m, Working Load > 300 kgf/m²)
1501Muffs with concerete filling
1502X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
1503MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
1504X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1505X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1506X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1507MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1508MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1509MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1510MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1511MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1512GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
1513GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1514D.O Fuse Unit 11KV
1515Lightening Arrester, 9 kV Station Class(Porcelain Type)
1516Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
1517Stay set complete
1518Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1519Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1520LT Distribution Panel Box with ACB(630A, 50kA, 4P) and SFU(250A, 4No MCCB)
1521LT Cable (3.5 Core) 400 mm²X 2 incommer
1522LT Cable (3.5 Core) 70 mm²X 4 Outgoing
1523Transformer Bed( Civil Work (As Per HPSR))
1524Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
1525Half Clamp (M.S. Flat 50X6 mm)
1526Full Clamps (M.S. Flat 50X6 mm)
1527Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1528Aluminium Thimble
1529Aluminium Thimble
1530Danger Plate
1531Barbed Wire
1532Red Oxide
1533Aluminium Paint
1534LT Switched Capacitors 60- KVAr for 400 KVA(rate per KVAr)
1535Distribution Transformer 630 KVA
1536Distribution Transformer (Ordinary), 11/0.4 kV,630 KVA
1537Steel Tubular Poles (10 m, Working Load > 300 kgf/m²)
1538Muffs with concerete filling
1539X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
1540MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s
1541X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1542X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1543X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1544MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1545MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1546MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1547MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1548MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1549GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
1550GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
1551D.O Fuse Unit 11KV
1552Lightening Arrester, 9 kV Station Class(Porcelain Type)
1553Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
1554Stay set complete
1555Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1556Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1557LT Distribution Panel Box with ACB(1000A, 50kA, 4P) and SFU(250A, 4No MCCB)
1558LT Cable (3.5 Core) 400 mm²X 2 incommer
1559LT Cable (3.5 Core) 95 mm²X 4 Outgoing
1560Transformer Bed( Civil Work (As Per HPSR))
1561Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
1562Half Clamp (M.S. Flat 50X6 mm)
1563Full Clamps (M.S. Flat 50X6 mm)
1564Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1565Aluminium Thimble
1566Aluminium Thimble
1567Danger Plate
1568Barbed Wire
1569Red Oxide
1570Aluminium Paint
1571LT Switched Capacitors 60KVAr for 630 KVA(rate per KVAr)
1572Distribution Transformer 25 kva , 22/.440v
1573Distribution Transformer (Ordinary), 22/0.4 kV,25 KVA
1574Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1575Muffs with concerete filling
1576X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
1577MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA"s
1578X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1579X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1580X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1581MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1582MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1583MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1584MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1585MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1586GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
1587GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
1588D.O Fuse Unit 22KV
1589Lightening Arrester, 18 kV Station Class(Porcelain Type)
1590Discs insulator sets (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
1591Stay set complete (HT)
1592Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1593Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1594LT Distribution Panel Box with MCCB(50A, 25 kA, 4P),O/G Kit Kit 63A 4Nos
1595Half Clamp (M.S. Flat 50X6 mm)
1596Full Clamps (M.S. Flat 50X6 mm)
1597Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1598Aluminium Thimble
1599Aluminium Thimble
1600Danger Plate
1601Barbed Wire
1602LT Cable (3.5 Core) 50 mm²
1603Red Oxide
1604Aluminium Paint
1605LT Switched Capacitors 4- KVAr for 25 KVA(rate per KVAr)
1606Distribution Transformer 63 kva , 22/.4kv
1607Distribution Transformer (Ordinary), 22/0.4 kV,63 KVA
1608Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1609Muffs with concerete filling
1610X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
1611MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA"s
1612X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
1613X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
1614X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer]
1615MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1616MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
1617MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
1618MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
1619MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
1620GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
1621GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
1622D.O Fuse Unit 22KV
1623Lightening Arrester, 18 kV Station Class(Porcelain Type)
1624Discs insulator sets (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
1625Stay set complete (HT)
1626Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1627Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
1628LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(32A, 4No, rewirable)
1629Half Clamp (M.S. Flat 50X6 mm)
1630Full Clamps (M.S. Flat 50X6 mm)
1631Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1632Aluminium Thimble
1633Aluminium Thimble
1634Danger Plate
1635Barbed Wire
1636LT Cable (3.5 Core) 120 mm²
1637Red Oxide
1638Aluminium Paint
1639LT Switched Capacitors 8- KVAr for 63 KVA(rate per KVAr)
1640Augmentation of DT as per given Scope of work
1641Augmentation of DT 25 KVA to 63 KVA
1642Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA
1643LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(32A, 4No, rewirable)
1644Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1645Aluminium Thimble
1646Aluminium Thimble
1647Danger Plate
1648LT Cable (3.5 Core)120mm²
1649Red Oxide
1650Aluminium Paint
1651LT Switched Capacitors 8- KVAr for 63 KVA(rate per KVAr)
1652Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1653Augmentation of DT 63 KVA to 100KVA
1654Distribution Transformer (Ordinary), 11/0.4 kV,100 KVA
1655LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(16A, 4No, rewirable)
1656Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1657Aluminium Thimble
1658Aluminium Thimble
1659Danger Plate
1660LT Cable (3.5 Core) 185 mm²
1661Red oxide
1662Aluminium Paint
1663LT Switched Capacitors 12- KVAr for 100KVA(rate per KVAr)
1664Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1665Augmentation of DT 100 KVA to 250KVA
1666Distribution Transformer (Ordinary), 11/0.4 kV,250 KVA
1667LT Distribution Panel Box with ACB(400A, 50 kA, 4P,1 No) and SFU(150A, 4No MCCB)
1668Half Clamp (M.S. Flat 50X6 mm)
1669Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1670Aluminium Thimble
1671Aluminium Thimble
1672LT Cable (3.5 Core) 300 mm²
1673LT Switched Capacitors 36- KVAr for 250KVA(rate per KVAr)
1674Civil Work Bedfor 250 KVA DT(As PER HPSR)
1675Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
1676Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1677Augmentation of DT 250 KVA to 400KVA
1678Distribution Transformer (Ordinary), 11/0.4 kV,400 KVA
1679LT Distribution Panel Box with ACB(630AI/C, 50 kA, 4P, & o/G 4 Nos MCCB 200A
1680Half Clamp (M.S. Flat 50X6 mm)
1681Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1682Aluminium Thimble
1683Aluminium Thimble
1684LT Cable (3.5 Core) 400 mm²X 2 incommer
1685LT Cable (3.5 Core) 70 mm²X 4 Outgoing
1686LT Switched Capacitors 60 KVAr for 400KVA(rate per KVAr)
1687Civil Work Bedfor 400 KVA DT(As PER HPSR)
1688Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
1689Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1690Augmentation of DT 400KVA to 630KVA
1691630 KVA,11/0.4KV DISTRIBUTION TRANSFORMER,
1692Transformer Bed( Civil Work (As Per HPSR))
1693LT Distribution Panel Box with ACB(1000A, 50 kA, 4P and SFU 4Nos MCCB 250A
1694M.S. NUTS &BOLTS OFF SIZES
1695Aluminium Thimble
1696Aluminium Thimble
1697LT Cable (3.5 Core) 400 mm² x 2 incoming
1698LT Cable (3.5 Core) 95 mm² x 4outgoing feeder
1699Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
1700Red Oxide
1701Aluminium paint
1702LT Switched Capacitors 60 KVAr for 630KVA(rate per KVAr)
1703Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1704Augmentation of DT 25 KVA to 63 KVAon 22kv line
1705Distribution Transformer (Ordinary), 22/0.4 kV,63 KVA
1706LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(32A, 4No, rewirable)
1707Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1708Aluminium Thimble
1709Aluminium Thimble
1710Danger Plate
1711LT Cable (3.5 Core)120mm²
1712Red Oxide
1713Aluminium Paint
1714LT Switched Capacitors 8- KVAr for 63 KVA(rate per KVAr)
1715Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1716Augmentation of DT 63 KVA to 100KVA on 22kv line
1717Distribution Transformer (Ordinary), 22/0.4 kV,100 KVA
1718LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(16A, 4No, rewirable)
1719Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1720Aluminium Thimble
1721Aluminium Thimble
1722Danger Plate
1723LT Cable (3.5 Core) 185 mm²
1724Red Oxide
1725Aluminium Paint
1726LT Switched Capacitors 12- KVAr for 100KVA(rate per KVAr)
1727Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1728Augmentation of DT 100 KVA to 250KVA on 22kv line
1729Distribution Transformer (Ordinary), 22/0.4 kV,250 KVA
1730LT Distribution Panel Box with MCCB(400A, 50kA, 4P) and SFU(150A, 4No MCCB)
1731Half Clamp (M.S. Flat 50X6 mm)
1732Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1733Aluminium Thimble
1734Aluminium Thimble
1735LT Cable (3.5 Core) 300 mm²
1736Civil Work Bedfor 250 KVA DT(As PER HPSR)
1737Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
1738LT Switched Capacitors 36 KVAr for 250KVA(rate per KVAr)
1739Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1740Augmentation of DT 250 KVA to 400KVA on 22kv line
1741Distribution Transformer (Ordinary), 22/0.4 kV,400 KVA
1742LT Distribution Panel Box with ACB(630A, 50kA, 4P) and SFU(250A, 4No MCCB)
1743Half Clamp (M.S. Flat 50X6 mm)
1744Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1745Aluminium Thimble
1746Aluminium Thimble
1747LT Cable (3.5 Core) 400 mm²X 2 incommer
1748LT Cable (3.5 Core) 70 mm²X 6 Outgoing
1749Civil Work Bedfor 400 KVA DT(As PER HPSR)
1750Chain link welded fencing , Angle Iron ,Gate etc for transformer fencing
1751Capacitor Bank of 60 KVR for 400kVA,
1752Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1753Augmentation of DT 400KVA to 630 KVA
1754630 KVA,22/0.4KV DISTRIBUTION TRANSFORMER,
1755Transformer Bed( Civil Work (As Per HPSR))
1756LT Distribution Panel Box with ACB(1000A, 50kA, 4P) and SFU(250A, 4No MCCB)
1757M.S. NUTS &BOLTS OFF SIZES
1758Aluminium Thimble
1759Aluminium Thimble
1760LT Cable (3.5 Core) 400 mm²X 2 incommer
1761LT Cable (3.5 Core) 95 mm²X 4 Outgoing
1762Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
1763Red Oxide
1764Aluminium paint
1765LT Switched Capacitors 60 KVAr for 630KVA(rate per KVAr)
1766Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1767Augmentation of LT Line
1768Augmentation of LT Lines -1 phase to 3-phasewith 50 Sq. mm Rabbit conductor
1769ACSR Rabbit Conductor 50 Sq. mm inclusive of sag and wastage
1770Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1771Muffs with concerete filling
1772Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1773Shackle Insulator (16 kN)
1774D-Iron (U- Clamps)
1775Earth Knob
1776LT Stay Set
1777Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1778Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1779Earthing Set complete
1780Spool Tie
1781Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1782Aluminium Paint
1783Red Oxide
1784Spiral PVC Spacer
1785Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1786Augmentation of LT Lines -2 phase tothree phase with 50 Sq. mm Rabbit conductor
1787ACSR Rabbit Conductor 50 Sq. mm inclusive of sag and wastage
1788Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1789Muffs with concerete filling
1790Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1791Shackle Insulator (16 kN)
1792D-Iron (U- Clamps)
1793Earth Knob
1794LT Stay Set
1795Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1796Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1797Earthing Set complete
1798Spool Tie
1799Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1800Aluminium Paint
1801Red Oxide
1802Spiral PVC Spacer
1803Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1804Augmentation of LT Lines -1 phase tothree phase with 100 Sq. mm Dog conductor
1805ACSR Dog Conductor 100 Sq. mm inclusive of sag and wastage
1806Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1807Muffs with concerete filling
1808Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1809Shackle Insulator (16 kN)
1810D-Iron (U- Clamps)
1811Earth Knob
1812LT Stay Set
1813Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1814Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1815Earthing Set complete
1816Spool Tie
1817Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1818Aluminium Paint
1819Red Oxide
1820Spiral PVC Spacer
1821Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1822Reconductoring of LT Lines -ACSR 3 phase 4Wire with 50 Sq. mm Rabbit conductor
1823ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
1824Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1825Muffs with concerete filling
1826Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1827Shackle Insulator (16 kN)
1828D-Iron (U- Clamps)
1829Earth Knob
1830LT Stay Set
1831Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1832Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1833Earthing Set complete
1834Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1835Spool Tie
1836Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1837Aluminium Paint
1838Red Oxide
1839Spiral PVC Spacer
1840Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1841Reconductoring with Dog Conductor
1842ACSR 6/1/4.72(100mm²) inclusive of sag and wastage
1843Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1844Muffs with concerete filling
1845Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
1846Shackle Insulator (16 kN)
1847D-Iron (U- Clamps)
1848Earth Knob
1849LT Stay Set
1850Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
1851Full Clamps [ 2 No for A.I + 1 No for Stay Set]
1852Earthing Set complete
1853Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
1854Spool Tie
1855Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1856Aluminium Paint
1857Red Oxide
1858Spiral PVC Spacer
1859Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1860LT AB Cable on poles [Size: (3x120 Sq, mm ) +70sqmm (Insulated)+16 sqmm{Inclusive 3% sagging & wastage)
1861LT AB Cable on poles [Size: (3x120 Sq, mm ) +70sqmm (Insulated) +16 sqmm{Inclusive 3% sagging & wastage)
1862Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
1863Muffs with concerete filling
1864Stay Set Complete
1865Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
1866Full Clamp for stay
1867Anchoring Assembly for LT
1868Suspension Assembly for LT
1869Facade Hooks for LT
1870Distribution box 3 phase 5 connectors as per TS
1871Piercing Connector as per TS
1872Cable for SMDB 3.5Core X 35sqmm
1873LT Earthing set complete (preferbly coil earthing)
1874Red Oxide
1875Aluminium paint
1876Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1877Augmentation of HT Lines(11/22KV )
1878Augmentation of existing Line with 11Kv Dog Conductor of 100Sqm
1879ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
1880Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1881Muffs with concerete filling
1882Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 2 structure
1883Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 2 structures
1884Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
188511 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
1886Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1887X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1888X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1889Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
189011 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
1891Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1892Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1893HT Earthing set complete (REC Constr. Stand. J-1)
1894Eye Hook for earth wire
1895Earth Wire Clamp
1896Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1897Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1898Danger Plate (250X200X1.6 mm)
1899Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1900Barbed Wire
1901Red Oxide
1902Aluminium Paint
1903Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1904Augmentation of existing Line with 11Kv Raccon Conductor of 80Sqm
1905ACSR 6/1/4.09MM (80mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
1906Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1907Muffs with concerete filling
1908Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 2 structure
1909Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 2 structures
1910Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
191111 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
1912Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1913X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1914X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1915Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
191611 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
1917Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1918Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1919HT Earthing set complete (REC Constr. Stand. J-1)
1920Eye Hook for earth wire
1921Earth Wire Clamp
1922Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1923Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1924Danger Plate (250X200X1.6 mm)
1925Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1926Barbed Wire
1927Red Oxide
1928Aluminium Paint
1929Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1930Augmentation of existing Line with 22Kv Rabbit Conductor of 50Sqm
1931ACSR 6/1/3.35MM (50mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
1932Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1933Muffs with concerete filling
1934Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 2 structure
1935Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 2 structures
1936Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
193722 kV Pin Insulators (Porcelain, 22 kV, 10 KN): 3 No per pole structure
1938Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1939X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1940X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1941Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
194222 kV Pin Insulators (Porcelain, 22 kV, 10 kN): 3 No per double pole structure
1943Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1944Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1945HT Earthing set complete (REC Constr. Stand. J-1)
1946Eye Hook for earth wire
1947Earth Wire Clamp
1948Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1949Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1950Danger Plate (250X200X1.6 mm)
1951Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1952Barbed Wire
1953Red Oxide
1954Aluminium Paint
1955Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1956Augmentation of existing Line with 11Kv Rabbit Conductor of 50Sqm
1957ACSR 6/1/3.35MM (50mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
1958Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
1959Muffs with concerete filling
1960Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 2 structure
1961Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 2 structures
1962Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
196311 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
1964Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
1965X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
1966X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
1967Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
196811 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
1969Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
1970Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
1971HT Earthing set complete (REC Constr. Stand. J-1)
1972Eye Hook for earth wire
1973Earth Wire Clamp
1974Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
1975Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
1976Danger Plate (250X200X1.6 mm)
1977Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
1978Barbed Wire
1979Red Oxide
1980Aluminium Paint
1981Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
1982Augmentation of HT Lines(33KV Line)
1983Augmentation of existing line with 33KV AL-59 of 150sqmm
1984AL-59 30/7/2.59 (150mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
1985Steel Tubular Poles (11 m, Working Load > 227 kg) (with Ruling Span 90 m, 10 No. Run thro" and 3 No. Dead End Structures)
1986Muffs (2000mm) with concerete filling
1987X-Arms: [MS Channel Iron C type (125X66X6) mm, Length: 3250 mm i/c tolerance 100 mm on either side] x 10 No. Structures
1988Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 1 No sides) /Run Throu" structures.
1989Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
1990X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
1991Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
1992X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
1993X-Arm (Horizontal) - MS Channel Iron C type: (125x66x6 mm), Length: 3250 mm i/c tolerance 100 mm on either side x 2 No.]
1994Discs insulator String sets on Dead End structures (comprising 3 No. Discs in each string: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps, Bend Stapples & straight Stapples etc.) x (3 No. conductors) x (2 No. sides)
199533 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per double pole structure
1996Dead End Clamp L/S
1997PG Clamp L/S
1998Stay set complete in all respect (2 No./Run Thro & 8 No. / Dead End)
1999Stay Wire (7/4.00 mm) (9.0 kg Per Stay Set)
2000HT Earthing set complete
2001Eye Hook for earth wire
2002Earth Reel
2003Half clamps: [On Double Pole Dead End structure: 6 No, Double Pole Run Thro" structure: 8 No]
2004Full clamps: [On Double Pole Dead End structure: 4 No, Double Pole Run Thro" structure: 4 No]
2005Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 20 mm F or more(with flat and spring washers)]
2006Barbed wire
2007Danger Plate (203X200X1.6mm)
2008Red Oxide
2009Aluminium Paint
2010Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
2011New 33 KV LineWork
2012New 33 KV Single Circuit Line with Dog Conductor on STP
2013ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
2014New 33 KV Single Circuit Line with Dog Conductor on 11 mtr STP
2015Muffs with concerete filling
2016X-Arms: [MS Channel Iron (100x50x6 mm, Length: 3250 mm i/c tolerance 100 mm on either side] x 10 No. Structures
2017Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 1 No sides) /Run Throu" structures.
2018Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
2019X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
2020Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
2021X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
2022X-Arm (Horizontal) - MS Channel Iron: (100x50x6 mm), Length: 3250 mm i/c tolerance 100 mm on either side x 2 No.]
2023Disc insulator String (Strain) sets: 3 No. Discs in each string: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (Single Circuit: 3 No. conductors) x (2 No. sides) /Dead Structures
202433 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per double pole structure
2025Stay set complete in all respect (2 No./Run Thro & 4 No. / Dead End)
2026Stay Wire (7/4.00 mm) (10 kg Per Stay Set)
2027HT Earthing set complete
2028Earth wire (GI, 6 SWG) {Includes Single wire length and Additional 1% (Sag and wastage)}@ 150 kg/km
2029Eye Hook for earth wire
2030Earth Reel
2031MS Channel Iron: 75x40x6, Length :3300 mm
2032Half clamps: [On Double Pole Dead End structure: 6 No, Double Pole Run Thro" structure: 8 No]
2033Full clamps: [On Double Pole Dead End structure: 4 No, Double Pole Run Thro" structure: 4 No]
2034Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 20 mm F or more(with flat and spring washers)]
2035Barbed wire
2036Danger Plate (203X200X1.6mm)
2037Red Oxide
2038Aluminium Paint
2039New 33 KV Single Circuit Line with AL-59 Conductor 150 sq mm. on Tubular Pole
2040AL-59 150 sq mm. ( Includes 3 Conductor lengths for 3 Phase and additional 1 % Wastage)
2041New 33 KV Single Circuit Line with Dog Conductor on 13 mtr STP
2042Muffs with concerete filling
2043X-Arms: [MS Channel Iron (100x50x6 mm, Length: 3250 mm i/c tolerance 100 mm on either side] x 10 No. Structures
2044Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 1 No sides) /Run Throu" structures.
2045Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
2046X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
2047Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
2048X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
2049X-Arm (Horizontal) - MS Channel Iron: (100x50x6 mm), Length: 3250 mm i/c tolerance 100 mm on either side x 2 No.]
2050Disc insulator String (Strain) sets: 3 No. Discs in each string: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (Single Circuit: 3 No. conductors) x (2 No. sides) /Dead Structures
205133 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per double pole structure
2052Stay set complete in all respect (2 No./Run Thro & 4 No. / Dead End)
2053Stay Wire (7/4.00 mm) (10 kg Per Stay Set)
2054HT Earthing set complete
2055Earth wire (GI, 6 SWG) {Includes Single wire length and Additional 1% (Sag and wastage)}@ 150 kg/km
2056Eye Hook for earth wire
2057Earth Reel
2058MS Channel Iron: 75x40x6, Length :3300 mm
2059Half clamps: [On Double Pole Dead End structure: 6 No, Double Pole Run Thro" structure: 8 No]
2060Full clamps: [On Double Pole Dead End structure: 4 No, Double Pole Run Thro" structure: 4 No]
2061Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 20 mm F or more(with flat and spring washers)]
2062Barbed wire
2063Danger Plate (203X200X1.6mm)
2064Red Oxide
2065Aluminium Paint
2066Cabling of 33kV line with 1x400 Sq. mm XLPE UG armoured Cable (3+1)(1.3CKM)
206733 kV XLPE Cable [Size:1x400mm²) {additional 1% wastage)]
206833 kV Cable Straight Through Jointing Kit [Size: 1x400 mm²]
206933 kV Cable Indoor Termination Kit [Size: 1x400 mm²]
207033 kV Cable Heat Shrink Outdoor Termination Kit [Size: 1x400mm²]
2071RCC cable cover (2 feet Long)
2072Sand Bag (50 Kg)
2073Route and Joint indicating stone
2074Inspection Chamber
2075GI Pipe earthing 40 mm x 2.5/3 m "B" class
2076Pipe HDPE of suitable size for 33KV XLPE 1X400 mm2
2077Lug AL Crimping 70 SQMM XLPE Single HOLE
2078Flat GI Size 25x6 mm
2079Cleat HDPE for Cable Support
2080G.I. Pipe 100 mm DIA "B" CLASS
2081Flat GI Size 50x6 mm
2082Channel MS Size 75x40 mm
2083Wiring tape (Printed PE UG utility Protection)
2084Cabling of 33kV line with 1x95 Sq. mm XLPE UG armoured Cable (3+1)(0.5CKM)
208533 kV XLPE Cable [Size:1x95mm²) {additional 1% wastage)]
208633 kV Cable Straight Through Jointing Kit [Size: 1x95 mm²]
208733 kV Cable Indoor Termination Kit [Size: 1x95 mm²]
208833 kV Cable Heat Shrink Outdoor Termination Kit [Size: 1x95mm²]
2089RCC cable cover (2 feet Long)
2090Sand Bag (50 Kg)
2091Route and Joint indicating stone
2092Inspection Chamber
2093GI Pipe earthing 40 mm x 2.5/3 m "B" class
2094Pipe HDPE of suitable size for 33KV XLPE 1X95 mm2
2095Lug AL Crimping 70 SQMM XLPE Single HOLE
2096Flat GI Size 25x6 mm
2097Cleat HDPE for Cable Support
2098G.I. Pipe 100 mm DIA "B" CLASS
2099Flat GI Size 50x6 mm
2100Channel MS Size 75x40 mm
2101Wiring tape (Printed PE UG utility Protection)
2102New 22kv Line works as per Scope of Work
210322KV line -22kv line on Steel Tubular pole with Dog Conductor -100Sq. mm
2104ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
210511M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
2106Muffs with concerete filling
2107Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
2108Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
2109Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
211022 kV Pin Insulators with GI Pin(Porcelain, 22 kV, 10 KN): 3 No per pole structure
2111Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
2112X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
2113X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
2114Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
211522 kV Pin Insulators (Porcelain, 24 kV, 10 kN): 3 No per double pole structure
2116Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
2117Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
2118HT Earthing set complete (REC Constr. Stand. J-1)
2119Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
2120Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
2121Eye Hook for earth wire
2122Earth Wire Clamp
2123MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
2124Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
2125Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
2126Danger Plate
2127Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2128Barbed Wire
2129Red Oxide
2130Aluminium Paint
2131GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
2132GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
2133New 22kv New Line on Steel Tubular Polewith Rabbit Conductor -50Sq. mm
2134ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
213511M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
2136Muffs with concerete filling
2137Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
2138Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
2139Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
214022 kV Pin Insulators with GI Pin(Porcelain, 22 kV, 10 KN): 3 No per pole structure
2141Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
2142X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
2143X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
2144Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
214522 kV Pin Insulators (Porcelain, 24 kV, 10 kN): 3 No per double pole structure
2146Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
2147Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
2148HT Earthing set complete (REC Constr. Stand. J-1)
2149Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
2150Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
2151Eye Hook for earth wire
2152Earth Wire Clamp
2153MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
2154Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
2155Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
2156Danger Plate
2157Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2158Barbed Wire
2159Red Oxide
2160Aluminium Paint
2161GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
2162GO AB Switch Unit (22kV, 400A, 25 KA ) Tripple pole O/D type
216322kv HT XLPE Cable3x120 Sq. mm {Inclusive 3% sagging & wastage)
216422kv HT XLPECable on poles [Size: (3x120 Sq, mm ) {Inclusive 3% sagging & wastage)
2165Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
2166Muffs with concerete filling
2167Stay Set Complete
2168Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
2169Full Clamp for stay
2170X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
2171Half Clamp for Cross Arm
2172Anchoring Assembly for HT
2173Suspension Assembly for HT
2174Facade Hooks for HT
2175Heat Shrinkable Straight Through Jointing Kit
2176Cable Termination kit
2177T-Jointing kit
2178HT Earthing set complete (preferbly coil earthing)
2179Red Oxide
2180Aluminium paint
2181steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
2182cable clamp made of GI sheet for 11kv 3x120 sq.mm
218311kv HT XLPE Cable3x185 Sq. mm {Inclusive 3% sagging & wastage)
218411 kv HT XLPECable on poles [Size: (3x185 Sqmm ) {Inclusive 3% sagging & wastage)
2185Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
2186Muffs with concerete filling
2187Stay Set Complete
2188Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
2189Full Clamp for stay
2190X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
2191Half Clamp for Cross Arm
2192Anchoring Assembly for HT
2193Suspension Assembly for HT
2194Facade Hooks for HT
2195Heat Shrinkable Straight Through Jointing Kit
2196Cable Termination kit
2197T-Jointing kit
2198HT Earthing set complete (preferbly coil earthing)
2199Red Oxide
2200Aluminium paint
2201steel catenary wire as per IS specification of 19 Strands & 7SWG type black 10mm
2202cable clamp made of GI sheet for 11kv 3x185 sq.mm
220311KV line -11kv line on Steel Tublar pole with Dog Conductor -100Sq. mm
2204ACSR 6/1/4.72 {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
220511M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
2206Muffs with concerete filling
2207Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
2208Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
2209Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
221011 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
2211Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
2212X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
2213X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
2214Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
221511 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
2216Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
2217Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
2218HT Earthing set complete (REC Constr. Stand. J-1)
2219Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
2220Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
2221Eye Hook for earth wire
2222Earth Wire Clamp
2223MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
2224Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
2225Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
2226Danger Plate
2227Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2228Barbed Wire
2229Red Oxide
2230Aluminium Paint
2231GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
2232GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
2233New 11kv New Line on Steel Tubular Polewith Rabbit Conductor -50Sq. mm
2234ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3F and Inclusive 3% (Sag, Jumpering and wastage}
223511M Steel Tublar Pole(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro" and 3 No. Double Pole Dead End Structures)
2236Muffs with concerete filling
2237Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure
2238Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
2239Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
224011 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
2241Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
2242X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
2243X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation
2244Discs insulator sets on Dead End structures (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
224511 kV Pin Insulators (Porcelain, 12. kV, 10 kN): 3 No per double pole structure
2246Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
2247Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
2248HT Earthing set complete (REC Constr. Stand. J-1)
2249Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
2250Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
2251Eye Hook for earth wire
2252Earth Wire Clamp
2253MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
2254Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro" structure: 2 No ]
2255Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro" structure: 2 No]
2256Danger Plate
2257Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2258Barbed Wire
2259Red Oxide
2260Aluminium Paint
2261GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
2262GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
226311kv HT AB Cable on poles [Size: (3x240 Sqmm ) {Inclusive 3% sagging & wastage)
226411kv HT AB Cable on poles [Size: (3x240 Sqmm ) {Inclusive 3% sagging & wastage)
2265Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
2266Muffs with concerete filling
2267Stay Set Complete
2268Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
2269Full Clamp for stay
2270X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
2271Half Clamp for Cross Arm
2272Anchoring Assembly for HT
2273Suspension Assembly for HT
2274Facade Hooks for HT
2275Heat Shrinkable Straight Through Jointing Kit
2276Cable Termination kit
2277T-Jointing kit
2278HT Earthing set complete (preferbly coil earthing)
2279Red Oxide
2280Aluminium paint
2281New33/11 KV Sub Station
22821X1.6MVA (New PSS at Gulana Mandi Circle)(Total-1No.)
2283Power Transformer (1.6 MVA, 33/11 kV, ONAN, Off Load Tap Changer, Outdoor)
2284Sub Station Transformer (100 kVA, 33/0.4 kV)
228533 kV Switchgear & Allied Equipment
2286a) 33 kV Control and Relay (CR) Panel (with NumericDifferential Relay, IEC 61850)
2287b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
2288c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
2289d) 33 kV Isolator (1250 A, 25kA,with Earth Switch) (Moterised)
2290e) 33 kV Isolator (1250 A, 25kA, without Earth Switch) (Moterised)
2291f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
2292g) 33 kV Current Transformer (33 kV, 1F, Multi Ratio Multi Core, Outdoor) (1 No. per F)
2293h) 33 kV Potential Transformer (33 kV/110 V, 1F, Multi-Core, Outdoor), (1No. per F)
2294i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
229511 kV Switchgear and Allied equipment: 01 No. incomer Bus
2296a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
2297b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3F, Indoor)
2298c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
2299d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m}+Spare
2300e) 11 kV Cable Termination Kit (185 mm², Outdoor)
2301f) 11 kV Cable Termination Kit (185mm², Indoor)
230211 kV Switchgear and Allied equipment: Single (2 No.) Outgoing Feeder
2303a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
2304b) 11 kV Isolator (12 kV, 1250 A, 25 kA,with Earth Switch, Outdoor)
2305c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
2306d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator}{50m+ Spare- 50m}
2307e) 11 kV Cable Termination Kit (185 mm², Outdoor)
2308f) 11 kV Cable Termination Kit (185 mm², Indoor)
2309LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
2310Capacitor Bank (3-?, 50 Hz, 1200 KVAr) [ IS:2834 ]
2311Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
2312Battery Bank with DualFCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
2313Distribution Panel (30V, DC)
2314Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomerMCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
2315Super Strcture and Bus Bar Arrangement
2316(i) R.S. Joists, size 12800x250x125 mm 8 supports
2317(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer"s LA, Station Transformer LA, I/C, Power Transformer"s CTs
2318(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA"s transformer etc. =100
2319(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
2320(v) Nuts & Bolts with Washers off sizes
2321BUS-BAR
2322(i) 3 Disc insulators Tension String complete with fitting
2323(ii) ACSR conductor 200 mm² at 10 % wastage
2324For jumpers at 2 m average 15 nos I.e.
2325(iii) Tee connections
2326(iv) PG clamps
2327Gantry for 2 no. outgoing feeder
2328(a) Steel tubular pole 11 m long for 1 No. out going Feeder
2329(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
2330(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross armsfor Sub-Station With 1 No. out going Feeder (11Kv)
2331(b) M.S. angle iron 50X50X6 mm 4.5 kg/mCross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
2332(d) M.S. Half clamps
2333(e) Full Clamp
2334(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2335ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
2336Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
2337Clamps for 1 Nos. out going Feeder
233811 kV Isolator
2339Earthing of 33/11KV Substation
2340Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA"s at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
2341GI Wire 6 No. SWG for screening etc.
2342Eye Block for screening
2343Tumbuckle for screening
2344GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottomFor Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
2345MS plates 150x150x6mm for two connection
234650x6 mm MS Flat connection with the mat to mat
2347Nut and bolts galvanized various sizes
2348Chequered plate cover 500x500x6mm i.e.11.8Kg
2349MS Rod 20 mm round 3 mtr long and weighing 2.47 kg/m and digging of 3 meter pits for earth rods 20 mm dia
2350Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
2351b)18 W LED Lamp complete with fittings
2352c)Post Erection for gate
2353d)Clamps for GI pipe bracket
2354e)Underground cable 16 mm² for yard lighting
2355f)PVC cable size 6 mm² for connecting LED lamp supply
2356g)Junction box i/c MCCB and other allied
2357Lighting Emergency (3 No LED Bulbs with holders / wire)
2358control cable: 2x2.5 mm²
2359control cable: 4x2.5 mm²
2360control cable:12x2.5 mm²
23613.5 core 95 mm² aluminium cable suitable for 415 V, AC
2362Fire Fighting Equipmentsas per TS
2363Safety Equipments & T & P as per TS
2364CIVIL WORKS
2365Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
2366water supply and sanitary installation for Control Room Building.
2367Electrical Installation for control room building (for 60 points)
2368Septic Tank (1 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
2369Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
2370Power Transformers Foundation suitable for upto 3.15 MVA (1 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
2371Substation Transformer Foundation (1 No)
2372VCB Foundation (2 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
2373Foundation of R.S. Joist supports (8 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
2374Foundation of CT, PT & LA(6 Nos) as per drawing ofHPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
2375Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
2376Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
2377Cost Of Boundary Wall (200Meter/Pss)as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
2378Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
2379Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
2380Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
2381Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
2382Chain Link Fencing with wooven mesh of GI wire 15MX30M
2383Cost of Soil Testing & Contour plans & design
2384Site Development at Gulana New PSS Mandi
2385Earth work in excavation in all kind of soils by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m or filling the selected earth behind retaining walls or under floors complete all as directed by engineer-in-charge
2386Earth work in excavation in all kind of soils by mechanical means (hydraulic excavator)/manual means in foundation trenches or drainsincluding dressing of sides and ramming of bottomsgetting out and disposal of excavated earth lead upto 50m and lift upto 1.5m or filling the selected earth behind retaining walls or under floors complete all as directed by Engineer-in-charge
2387Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering work upto plinth level in 1:5:10 (1 cement : 5 Sand : 10 graded stone aggregate 40mm nominal size) complete all as specified and as directed by Engineer-in-charge.
2388Providing and laying cemengt concrete 1:3:6 (1 cement :3 Coarse sand : 6 graded stone aggregate 20mm nominal size) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,, buttresses, string or lacing courses, parapets coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc, upto floor fivelevel, excluding the cost of centering, shuttering and finishing complete all as specified and as directed by Engineer-in-charge.
2389Providingcentering and shutteringformwork with steel plates giving fair finish including strutting, propping etc and removal of form work for retaining walls, return walls, walls (any thickness) including attachaed pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc
2390Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed 75mm dia conforming to IS 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10mm gap for thermal expansion.
2391Supply, filling dry hand packing tightly boulders of size 5cm to 20cm in required thickness for all leads and lifts, all complete as per direction of Engineer-in-charge
2392Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2393New33/11 KV Sub Station
23941X3.15MVA (Thachi & Gushaini in Kullu Circle )Total =2Nos
2395Power Transformer (3.15 MVA, 33/11 kV, ONAN, Off Load Tap Changer, Outdoor)
2396Sub Station Transformer (100 kVA, 33/0.4 kV)
239733 kV Switchgear & Allied Equipment
2398a) 33 kV Control and Relay (CR) Panel (with NumericDifferential Relay, IEC 61850)
2399b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
2400c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
2401d) 33 kV Isolator (1250 A, 25kA,with Earth Switch) (Moterised)
2402e) 33 kV Isolator (1250 A, 25kA, without Earth Switch) (Moterised)
2403f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
2404g) 33 kV Current Transformer (33 kV, 1F, Multi Ratio Multi Core, Outdoor) (1 No. per F)
2405h) 33 kV Potential Transformer (33 kV/110 V, 1F, Multi-Core, Outdoor), (1No. per F)
2406i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
240711 kV Switchgear and Allied equipment: 01 No. incomer Bus
2408a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
2409b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3F, Indoor)
2410c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
2411d) 11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m}+Spare
2412e) 11 kV Cable Termination Kit (400 mm², Outdoor)
2413f) 11 kV Cable Termination Kit (400 mm², Indoor)
241411 kV Switchgear and Allied equipment: Single (2 No.) Outgoing Feeder
2415a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
2416b) 11 kV Isolator (12 kV, 1250 A, 25 kA,with Earth Switch, Outdoor)
2417c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
2418d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator}{50m+ Spare- 50m}
2419e) 11 kV Cable Termination Kit (185 mm², Outdoor)
2420f) 11 kV Cable Termination Kit (185 mm², Indoor)
2421LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
2422Capacitor Bank (3-?, 50 Hz, 1200 KVAr) [ IS:2834 ]
2423Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
2424Battery Bank with DualFCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
2425Distribution Panel (30V, DC)
2426Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomerMCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
2427Super Strcture and Bus Bar Arrangement
2428(i) R.S. Joists, size 12800x250x125 mm 8 supports
2429(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer"s LA, Station Transformer LA, I/C, Power Transformer"s CTs
2430(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA"s transformer etc. =100
2431(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
2432(v) Nuts & Bolts with Washers off sizes
2433BUS-BAR
2434(i) 3 Disc insulators Tension String complete with fitting
2435(ii) ACSR conductor 200 mm² at 10 % wastage
2436For jumpers at 2 m average 15 nos I.e.
2437(iii) Tee connections
2438(iv) PG clamps
2439Gantry for 2 no. outgoing feeder
2440(a) Steel tubular pole 11 m long for 1 No. out going Feeder
2441(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
2442(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross armsfor Sub-Station With 1 No. out going Feeder (11Kv)
2443(b) M.S. angle iron 50X50X6 mm 4.5 kg/mCross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
2444(d) M.S. Half clamps
2445(e) Full Clamp
2446(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2447ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
2448Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
2449Clamps for 1 Nos. out going Feeder
245011 kV Isolator
2451Cost of Earthing
2452Earthing of 33/11KV Substation
2453Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA"s at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
2454GI Wire 6 No. SWG for screening etc.
2455Eye Block for screening
2456Tumbuckle for screening
2457GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottomFor Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
2458MS plates 150x150x6mm for two connection
245950x6 mm MS Flat connection with the mat to mat
2460Nut and bolts galvanized various sizes
2461Chequered plate cover 500x500x6mm i.e.11.8Kg
2462MS Rod 20 mm round 3 mtr long and weighing 2.47 kg/m and digging of 3 meter pits for earth rods 20 mm dia
2463i) Cost of Material for Earth Mat laying
2464ii) Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points (body & neutral) at 10 Mtr each (3x10)x1.05=31.5 Mtr (b) For 2 No. LA"s at 4.2 Mtr each 4.2x2x1.05=8.82 Mtr (c) For 15 nos. 33 kV super structure at 11.50 Mtr each 15x11.50x1.05 =173.25 Mtr i.e. 173 Mtr (d) For 12 Nos. VCB & CT body earthing at 10 m Each (12x10)x1.05 = 126 Mtr Total (a+b+c+d) =339.57 m i.e. 340 Mtr and 5% welding of riser and corrosion protection .816 Mt +5% of .816 MT= 857
2465iii) GI wire no. 6 SWG for screening etc.
2466iv) Eye block for screening
2467v) Turnbuckle for Screening
2468Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
2469b)18 W LED Lamp complete with fittings
2470c)Post Erection for gate
2471d)Clamps for GI pipe bracket
2472e)Underground cable 16 mm² for yard lighting
2473f)PVC cable size 6 mm² for connecting LED lamp supply
2474g)Junction box i/c MCCB and other allied
2475Lighting Emergency (3 No LED Bulbs with holders / wire)
2476control cable: 2x2.5 mm²
2477control cable: 4x2.5 mm²
2478control cable:12x2.5 mm²
24793.5 core 95 mm² aluminium cable suitable for 415 V, AC
2480Fire Fighting Equipmentsas per TS
2481Safety Equipments & T & P as per TS
2482Civil Works
2483Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
2484water supply and sanitary installation for Control Room Building.
2485Electrical Installation for control room building (for 60 points)
2486Septic Tank (1 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
2487Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
2488Power Transformers Foundation suitable for upto 3.15 MVA (2 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
2489Substation Transformer Foundation (1 No)
2490VCB Foundation (5 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
2491Foundation of R.S. Joist supports (16 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
2492Foundation of CT, PT & LA(14Nos) as per drawing ofHPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
2493Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
2494Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
2495Cost Of Boundary Wall (200Meter/Pss)as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
2496Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
2497Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
2498Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
2499Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
2500Chain Link Fencing with wooven mesh of GI wire 15MX30M
2501Cost of Soil Testing & Contour plans & design
2502Development of Site and approach road for proposed 33/11 KV Sub-Station at Thachi under Electrical sub Division HPSEBL Balichowki.
2503Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.ordinary rock (all kind of soil)
2504Carriage of Earth work upto a lead of 10 km by mechanical means.
2505Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size).
2506Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:- 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
2507Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
2508Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
2509Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes for weep holes in fire protection wall complete in all respect.75 mm diameter.
2510Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge.
2511Development of Site for proposed 33/11 KV, 2X1.60 MVA Sub-Station at Gushaini under Electrical Division HPSEBL Banjar.
2512Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.Hard rock (blasting prohibited).
2513Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size).
2514Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Hot rolled deformed bars.
2515Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) .
2516Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size).
2517Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
2518Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
2519Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
2520Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m :all kind of soil.
2521Preparation and consolidation of sub grade with power road roller of 8 to 12 Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12(D=100mm with tolerance of ± 2%) Zinic+PVC coated, Mesh wire diameter 2.7/3.7mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per directions of Engineer-in-charge
2522Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes for weep holes in fire protection wall complete in all respect.75 mm diameter.
2523Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
2524Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
2525Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge.
2526New33/11 KV Sub Station
25272X3.15 MVA (PSS Jhaniyara in Hamirpur Circle,Nerchowk in Bilaspur) Total = 2 nos
2528Power Transformer (3.15 MVA, 33/11 kV, ONAN, Off Load Tap Changer, Outdoor)
2529Sub Station Transformer (100 kVA, 33/0.4 kV)
253033 kV Switchgear & Allied Equipment
2531a) 33 kV Control and Relay (CR) Panel (with NumericDifferential Relay, IEC 61850)
2532b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
2533c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
2534d) 33 kV Isolator (1250 A, 25kA,with Earth Switch) (Moterised)
2535e) 33 kV Isolator (1250 A, 25kA, without Earth Switch) (Moterised)
2536f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
2537g) 33 kV Current Transformer (33 kV, 1F, Multi Ratio Multi Core, Outdoor) (1 No. per F)
2538h) 33 kV Potential Transformer (33 kV/110 V, 1F, Multi-Core, Outdoor), (1No. per F)
2539i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
254011 kV Switchgear and Allied equipment: 02 No. incomer Bus
2541a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
2542b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3F, Indoor)
2543c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
2544d) 11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m}+Spare
2545e) 11 kV Cable Termination Kit (400 mm², Outdoor)
2546f) 11 kV Cable Termination Kit (400 mm², Indoor)
254711 kV Switchgear and Allied equipment: Single (8 No.) Outgoing Feeder
2548a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
2549c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
2550d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator}{50m+ Spare- 50m}
2551e) 11 kV Cable Termination Kit (185 mm², Outdoor)
2552f) 11 kV Cable Termination Kit (185 mm², Indoor)
2553LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
2554Capacitor Bank (3-?, 50 Hz, 1200 KVAr) [ IS:2834 ]
2555Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
2556Battery Bank with DualFCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
2557Distribution Panel (30V, DC)
2558Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomerMCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
2559Super Strcture and Bus Bar Arrangement
2560(i) R.S. Joists, size 12800x250x125 mm 16 supports
2561(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer"s LA, Station Transformer LA, I/C, Power Transformer"s CTs
2562(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA"s transformer etc.
2563(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
2564(v) Nuts & Bolts with Washers off sizes
2565BUS-BAR
2566(i) 3 Disc insulators Tension String complete with fitting
2567(ii) ACSR conductor 200 mm² at 10 % wastage
2568For jumpers at 2 m average 30 nos I.e.
2569(iii) Tee connections
2570(iv) PG clamps
2571Gantry FOR 33 kV
2572(a) Steel tubular pole 11 m long
2573(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
2574(a)5.5 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross armsfor Sub-Station With 1 No. out going Feeder (33kV)
2575(b) M.S. angle iron 50X50X6 mm 4.5 kg/mCross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
2576(d) M.S. Half clamps
2577(e) Full Clamp
2578(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2579ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
2580Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
2581Clamps for 1 Nos. out going Feeder
258233 kV Isolator Moterised with ES
2583Gantry for 8 no. outgoing feeder
2584(a) Steel tubular pole 11 m long for 8 No. out going Feeder
2585(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
2586(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross armsfor Sub-Station With 1 No. out going Feeder (11Kv)
2587(b) M.S. angle iron 50X50X6 mm 4.5 kg/mCross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
2588(d) M.S. Half clamps
2589(e) Full Clamp
2590(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2591ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
2592Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
2593Clamps forout going Feeder
259411 kV Isolator
2595Earthing of 33/11KV Substation
2596Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA"s at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
2597GI Wire 6 No. SWG for screening etc.
2598Eye Block for screening
2599Tumbuckle for screening
2600GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottomFor Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
2601MS plates 150x150x6mm for two connection
260250x6 mm MS Flat connection with the mat to mat
2603Nut and bolts galvanized various sizes
2604Chequered plate cover 500x500x6mm i.e.11.8Kg
2605MS Rod 20 mm round 3 mtr long and weighing 2.47 kg/m and digging of 3 meter pits for earth rods 20 mm dia
2606Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
2607b)18 W LED Lamp complete with fittings
2608c)Post Erection for gate
2609d)Clamps for GI pipe bracket
2610e)Underground cable 16 mm² for yard lighting
2611f)PVC cable size 6 mm² for connecting LED lamp supply
2612g)Junction box i/c MCCB and other allied
2613Lighting Emergency (3 No LED Bulbs with holders / wire)
2614control cable: 2x2.5 mm²
2615control cable: 4x2.5 mm²
2616control cable:12x2.5 mm²
26173.5 core 95 mm² aluminium cable suitable for 415 V, AC
2618Fire Fighting Equipmentsas per TS
2619Safety Equipments & T & P as per TS
2620CIVIL WORKS
2621Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
2622water supply and sanitary installation for Control Room Building.
2623Electrical Installation for control room building (for 60 points)
2624Septic Tank (1 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
2625Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
2626Power Transformers Foundation suitable for upto 3.15 MVA (2 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
2627Substation Transformer Foundation (1 No)
2628VCB Foundation (5 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
2629Foundation of R.S. Joist supports (16 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
2630Foundation of CT, PT & LA(14Nos) as per drawing ofHPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
2631Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
2632Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
2633Cost Of Boundary Wall (200Meter/Pss)as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
2634Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
2635Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
2636Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
2637Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
2638Chain Link Fencing with wooven mesh of GI wire 15MX30M
2639Cost of Soil Testing & Contour plans & design
2640Site Development at 33/11 KV Sub-Station at Jhaniyara under Electrical Division, HPSEBL-Hamirpur for RDSS Scheme
2641Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2642Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soils
2643Carriage of excavated earth by mechanical means for disposal in the dumping area for a lead of 5 Km
2644Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
2645Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand): 10 graded stone aggregate 40 mm nominal size)
2646Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
2647Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominal size).
2648Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in flooring , in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
2649Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
2650Site Development at33/11KV Nerchowk at Bilaspur circle
2651Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of .foundation etc. complete.
2652Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
2653Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand) : 4 gradedstone aggregate 20 mm nominal size
2654Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
2655Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
2656Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
2657Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
2658Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
2659Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :100x58x1.90 mm
2660Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm
2661New33/11 KV Sub Station
26622X6.3 MVA (Mahoul at kullu Circle, Total No:-1)
2663Power Transformer (6.3 MVA, 33/11 kV, ONAN, Off Load Tap Changer, Outdoor)
2664Sub Station Transformer (100 kVA, 33/0.4 kV)
266533 kV Switchgear & Allied Equipment
2666a) 33 kV Control and Relay (CR) Panel (with NumericDifferential Relay, IEC 61850)
2667b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
2668c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
2669d) 33 kV Isolator (1250 A, 25kA,with Earth Switch) (Moterised)
2670e) 33 kV Isolator (1250 A, 25kA, without Earth Switch) (Moterised)
2671f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
2672g) 33 kV Current Transformer (33 kV, 1F, Multi Ratio Multi Core, Outdoor) (1 No. per F)
2673h) 33 kV Potential Transformer (33 kV/110 V, 1F, Multi-Core, Outdoor), (1No. per F)
2674i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
267511 kV Switchgear and Allied equipment: 02 No. incomer Bus
2676a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
2677b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3F, Indoor)
2678c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
2679d) 11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m}+Spare
2680e) 11 kV Cable Termination Kit (400 mm², Outdoor)
2681f) 11 kV Cable Termination Kit (400 mm², Indoor)
268211 kV Switchgear and Allied equipment: Single (8 No.) Outgoing Feeder
2683a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
2684c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
2685d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator}{50m+ Spare- 50m}
2686e) 11 kV Cable Termination Kit (185 mm², Outdoor)
2687f) 11 kV Cable Termination Kit (185 mm², Indoor)
2688LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
2689Capacitor Bank (3-?, 50 Hz, 1800 KVAr) [ IS:2834 ]
2690Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
2691Battery Bank with Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
2692Distribution Panel (30V, DC)
2693Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomerMCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
2694Super Strcture and Bus Bar Arrangement
2695(i) R.S. Joists, size 12800x250x125 mm 16 supports
2696(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer"s LA, Station Transformer LA, I/C, Power Transformer"s CTs
2697(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA"s transformer etc.
2698(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
2699(v) Nuts & Bolts with Washers off sizes
2700BUS-BAR
2701(i) 3 Disc insulators Tension String complete with fitting
2702(ii) ACSR conductor 200 mm² at 10 % wastage
2703For jumpers at 2 m average 30 nos I.e.
2704(iii) Tee connections
2705(iv) PG clamps
2706Gantry FOR 33 kV
2707(a) Steel tubular pole 11 m long
2708(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
2709(a)5.5 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross armsfor Sub-Station With 1 No. out going Feeder (33kV)
2710(b) M.S. angle iron 50X50X6 mm 4.5 kg/mCross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
2711(d) M.S. Half clamps
2712(e) Full Clamp
2713(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2714ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
2715Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
2716Clamps for 1 Nos. out going Feeder
271733 kV Isolator Moterised with ES
2718Gantry for 8 no. outgoing feeder
2719(a) Steel tubular pole 11 m long for 8 No. out going Feeder
2720(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
2721(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross armsfor Sub-Station With 1 No. out going Feeder (11Kv)
2722(b) M.S. angle iron 50X50X6 mm 4.5 kg/mCross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
2723(d) M.S. Half clamps
2724(e) Full Clamp
2725(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2726ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
2727Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
2728Clamps forout going Feeder
272911 kV Isolator
2730Cost of Earthing
2731Earthing of 33/11KV Substation
2732Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA"s at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
2733GI Wire 6 No. SWG for screening etc.
2734Eye Block for screening
2735Tumbuckle for screening
2736GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottomFor Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
2737MS plates 150x150x6mm for two connection
273850x6 mm MS Flat connection with the mat to mat
2739Nut and bolts galvanized various sizes
2740Chequered plate cover 500x500x6mm i.e.11.8Kg
2741MS Rod 20 mm round 3 mtr long and weighing 2.47 kg/m and digging of 3 meter pits for earth rods 20 mm dia
2742Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
2743b)18 W LED Lamp complete with fittings
2744c)Post Erection for gate
2745d)Clamps for GI pipe bracket
2746e)Underground cable 16 mm² for yard lighting
2747f)PVC cable size 6 mm² for connecting LED lamp supply
2748g)Junction box i/c MCCB and other allied
2749Lighting Emergency (3 No LED Bulbs with holders / wire)
2750control cable: 2x2.5 mm²
2751control cable: 4x2.5 mm²
2752control cable:12x2.5 mm²
27533.5 core 95 mm² aluminium cable suitable for 415 V, AC
2754Fire Fighting Equipmentsas per TS
2755Safety Equipments & T & P as per TS
2756CIVIL WORKS
2757Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
2758water supply and sanitary installation for Control Room Building.
2759Electrical Installation for control room building (for 60 points)
2760Septic Tank (1 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
2761Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
2762Power Transformers Foundation suitable for upto 10 MVA (2 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
2763Substation Transformer Foundation (1 No)
2764VCB Foundation (5 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
2765Foundation of R.S. Joist supports (16 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
2766Foundation of CT, PT & LA(14Nos) as per drawing ofHPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
2767Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
2768Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
2769Cost Of Boundary Wall (200Meter/Pss)as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
2770Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
2771Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
2772Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
2773Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
2774Chain Link Fencing with wooven mesh of GI wire 15MX30M
2775Cost of Soil Testing & Contour plans & design
2776Site development for proposed 33/11KVsubstation at mohal under ED HPSEBL,Kullu.
2777Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
2778Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
2779Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar
2780Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead
2781Demolishing Rcc work by mechnical means and stockpilling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
2782Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:Channels, angles, tees and flats
2783Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. all kind of soil
2784Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting outanddisposal ofexcavatedearthleadupto50 mandliftupto 1.5 m, as directed by Engineer-in-charge Ordinary rock
2785Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6
2786Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4
2787Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : - Cement mortar 1:4 (1 cement : 4 coarse sand)
2788Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 (1 cement : 4 coarse sand)
2789Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Hot rolled deformed bars
2790Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
2791Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
2792Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
2793Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :Payment to be made per metre cost of total length of barbed wire used. with GI barbed wire.
2794Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturer’s specifications: - Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
2795Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturer’s specifications: - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
2796AUGMENTATION of 33/11 kv Substation
2797Aug to 1X3.15(Talyahar at Mandi Circle) Total = 1 Nos
2798Power Transformer (3.15 MVA, 33/11 kV, ONAN, Off Load Tap Changer, Outdoor)
279911 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m+ Spare- 50m}
280011 kV Cable Termination Kit (400 mm², Outdoor)
280111 kV Cable Termination Kit (400 mm², Indoor)
2802Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
2803CIVIL WORKS
2804Transformers Foundation [Power X-former]
2805Trench O.B Type additional
2806Aug to 2X3.15at Bhutti -Kullu Total = 1 Nos
2807Power Transformer (3.15 MVA, 33/ 11 kV, ONAN, Off Load Tap Changer, Outdoor)
280811 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m+ Spare- 50m}
280911 kV Cable Termination Kit (400 mm², Outdoor)
281011 kV Cable Termination Kit (400 mm², Indoor)
2811EARTHING (33 kV Sub-Station)
2812Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
2813CIVIL WORKS
2814Transformers Foundation [Power X-former]
281533/11 KV Sub Station
2816Aug to2X6.3 MVA (Banjar,Nagwain,Sarabai,Jari,Bajaura In Kullu Circle),(Chauntra,Kalkhar in Mandi Circle)(Ladrour,Tauni Devi in Hamirpur Circle) Total = 9 Nos
2817Power Transformer (6.3 MVA, 33/11 kV, ONAN, Off Load Tap Changer, Outdoor)
2818Sub Station Transformer (100 kVA, 33/0.4 kV)
281933 kV Switchgear & Allied Equipment: with 01 No., 33 kV Incomer
282033 kV Control and Relay (CR) Panel (with NumericDifferential Relay, IEC 61850)
282133 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
282233 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
2823e) 33 kV Isolator (1250 A, 25kA, without Earth Switch) (Moterised)
282433 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
282533 kV Current Transformer (33 kV, 1F, Multi Ratio Multi Core, Outdoor) (1 No. per F)
282633 kV Potential Transformer (33 kV/110 V, 1F, Multi-Core, Outdoor), (1No. per F)
2827Battery Bank with Dual FCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
282811 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m+ Spare- 50m}
282911 kV Cable Termination Kit (400 mm², Outdoor)
283011 kV Cable Termination Kit (400 mm², Indoor)
283111 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator}{50m+ Spare- 50m}
283211 kV Cable Termination Kit (185 mm², Outdoor)
283311 kV Cable Termination Kit (185 mm², Indoor)
2834EARTHING (33 kV Sub-Station)
2835Additional Control cable
28364 core 2.5 mm2
28372 core 2.5 mm2
283812 core 2.5 mm2
2839Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
2840CIVIL WORKS
2841Transformers Foundation [Power X-former]
2842Station X-former Foundation
2843Circuit Breaker Foundation
2844Trenches
2845I) Outdoor Trench
2846Baffle wall in case of 2 No. Transformer
2847Foundation of VCB
2848Aug to 10 mVA (Naggar, Bhuntar in Kullu Circle) Total = 2 Nos
2849Power Transformer (10MVA, 33/11 kV, ONAN, OLTC, Outdoor)
285033 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
285111 kV Cable (11 kV, 630 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m+ Spare- 50m}
285211 kV Cable Termination Kit (630 mm², Outdoor)
285311 kV Cable Termination Kit (630 mm², Indoor)
2854Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
2855CIVIL WORKS
2856Transformers Foundation
2857New33/11 KV Sub Station
28581X3.15 MVA (New Bus Stand Hamirpur Bypass Hamirpur Circle) Total = 1 Nos
2859Power Transformer (3.15 MVA, 33/11 kV, ONAN, Off Load Tap Changer, Outdoor)
2860Sub Station Transformer (100 kVA, 33/0.4 kV)
286133 kV Switchgear & Allied Equipment
2862a) 33 kV Control and Relay (CR) Panel (with NumericDifferential Relay, IEC 61850)
2863b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
2864c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
2865d) 33 kV Isolator (1250 A, 25kA,with Earth Switch) (Moterised)
2866e) 33 kV Isolator (1250 A, 25kA, without Earth Switch) (Moterised)
2867f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
2868g) 33 kV Current Transformer (33 kV, 1F, Multi Ratio Multi Core, Outdoor) (1 No. per F)
2869h) 33 kV Potential Transformer (33 kV/110 V, 1F, Multi-Core, Outdoor), (1No. per F)
2870i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
287111 kV Switchgear and Allied equipment: 01 No. incomer Bus
2872a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
2873b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3F, Indoor)
2874c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
2875d) 11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m}+Spare
2876e) 11 kV Cable Termination Kit (400 mm², Outdoor)
2877f) 11 kV Cable Termination Kit (400 mm², Indoor)
287811 kV Switchgear and Allied equipment: Single (2 No.) Outgoing Feeder
2879a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
2880b) 11 kV Isolator (12 kV, 1250 A, 25 kA,with Earth Switch, Outdoor) Motorised
2881c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
2882d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator}{50m+ Spare- 50m}
2883e) 11 kV Cable Termination Kit (185 mm², Outdoor)
2884f) 11 kV Cable Termination Kit (185 mm², Indoor)
2885LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
2886Capacitor Bank (3-?, 50 Hz, 1200 KVAr) [ IS:2834 ]
2887Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
2888Battery Bank with DualFCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
2889Distribution Panel (30V, DC)
2890Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomerMCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
2891Super Strcture and Bus Bar Arrangement
2892(i) R.S. Joists, size 12800x250x125 mm 8 supports
2893(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer"s LA, Station Transformer LA, I/C, Power Transformer"s CTs
2894(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA"s transformer etc. =100
2895(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
2896(v) Nuts & Bolts with Washers off sizes
2897BUS-BAR
2898(i) 3 Disc insulators Tension String complete with fitting
2899(ii) ACSR conductor 200 mm² at 10 % wastage
2900For jumpers at 2 m average 15 nos I.e.
2901(iii) Tee connections
2902(iv) PG clamps
2903Gantry for 2 no. outgoing feeder
2904(a) Steel tubular pole 11 m long for 1 No. out going Feeder
2905(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
2906(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross armsfor Sub-Station With 1 No. out going Feeder (11Kv)
2907(b) M.S. angle iron 50X50X6 mm 4.5 kg/mCross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
2908(d) M.S. Half clamps
2909(e) Full Clamp
2910(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
2911ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
2912Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
2913Clamps for 1 Nos. out going Feeder
291411 kV Isolator
2915Earthing of 33/11KV Substation
2916Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA"s at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
2917GI Wire 6 No. SWG for screening etc.
2918Eye Block for screening
2919Tumbuckle for screening
2920GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottomFor Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
2921MS plates 150x150x6mm for two connection
292250x6 mm MS Flat connection with the mat to mat
2923Nut and bolts galvanized various sizes
2924Chequered plate cover 500x500x6mm i.e.11.8Kg
2925MS Rod 20 mm round 3 mtr long and weighing 2.47 kg/m and digging of 3 meter pits for earth rods 20 mm dia
2926Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
2927b)18 W LED Lamp complete with fittings
2928c)Post Erection for gate
2929d)Clamps for GI pipe bracket
2930e)Underground cable 16 mm² for yard lighting
2931f)PVC cable size 6 mm² for connecting LED lamp supply
2932g)Junction box i/c MCCB and other allied
2933Lighting Emergency (3 No LED Bulbs with holders / wire)
2934control cable: 2x2.5 mm²
2935control cable: 4x2.5 mm²
2936control cable:12x2.5 mm²
29373.5 core 95 mm² aluminium cable suitable for 415 V, AC
2938Fire Fighting Equipmentsas per TS
2939Safety Equipments & T & P as per TS
2940Civil Works
2941Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
2942water supply and sanitary installation for Control Room Building.
2943Electrical Installation for control room building (for 60 points)
2944Septic Tank (1 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
2945Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
2946Power Transformers Foundation suitable for upto 3.15 MVA (2 Nos) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
2947Substation Transformer Foundation (1 No)
2948VCB Foundation (5 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
2949Foundation of R.S. Joist supports (16 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
2950Foundation of CT, PT & LA(14Nos) as per drawing ofHPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
2951Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
2952Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
2953Cost Of Boundary Wall (200Meter/Pss)as per drawing ofHPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
2954Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
2955Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
2956Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
2957Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
2958Chain Link Fencing with wooven mesh of GI wire 15MX30M
2959Cost of Soil Testing & Contour plans & design
2960Site Development (New Bus Stand Hamirpur Bypass Hamirpur Circle)
2961Clearing jungle including uprooting of rank vegetation,grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2962Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soils
2963Carriage of excavated earth by mechanical means for disposal in the dumping area for a lead of 5 Km
2964Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
2965Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand): 10 graded stone aggregate 40 mm nominal size)
2966Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
2967Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominal size).
2968Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in flooring , in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
2969Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
2970Aug to1X3.15 MVA (Kohla in Hamirpur Circle) Total = 1 Nos
2971Power Transformer (3.15 MVA, 33/11 kV, ONAN, Off Load Tap Changer, Outdoor)
2972Sub Station Transformer (100 kVA, 33/0.4 kV)
297333 kV Switchgear & Allied Equipment: with 01 No., 33 kV Incomer
297433 kV Control and Relay (CR) Panel (with NumericDifferential Relay, IEC 61850)
297533 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
297633 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
2977d) 33 kV Isolator (1250 A, 25kA,with Earth Switch) (Moterised)
2978e) 33 kV Isolator (1250 A, 25kA, without Earth Switch) (Moterised)
297933 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
298033 kV Current Transformer (33 kV, 1F, Multi Ratio Multi Core, Outdoor) (1 No. per F)
298111 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m+ Spare- 50m}
298211 kV Cable Termination Kit (400 mm², Outdoor)
298311 kV Cable Termination Kit (400 mm², Indoor)
2984EARTHING (33 kV Sub-Station)
2985Additional Control cable
29864 core 2.5 mm2
29872 core 2.5 mm2
298812 core 2.5 mm2
2989Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge
2990CIVIL WORKS
2991Transformers Foundation [Power X-former]
2992Circuit Breaker Foundation
2993I) Outdoor Trench
2994I) Indoor Trench
2995New 33 KV Single Circuit Line with Dog Conductor on STP for EV Charging station
2996ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
2997New 33 KV Single Circuit Line with Dog Conductor on 13 mtr STP
2998Muffs with concerete filling
2999X-Arms: [MS Channel Iron (100x50x6 mm, Length: 3250 mm i/c tolerance 100 mm on either side] x 10 No. Structures
3000Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 1 No sides) /Run Throu" structures.
3001Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
3002X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
3003Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
3004X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
3005X-Arm (Horizontal) - MS Channel Iron: (100x50x6 mm), Length: 3250 mm i/c tolerance 100 mm on either side x 2 No.]
3006Disc insulator String (Strain) sets: 3 No. Discs in each string: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (Single Circuit: 3 No. conductors) x (2 No. sides) /Dead Structures
300733 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per double pole structure
3008Stay set complete in all respect (2 No./Run Thro & 4 No. / Dead End)
3009Stay Wire (7/4.00 mm) (10 kg Per Stay Set)
3010HT Earthing set complete
3011Earth wire (GI, 6 SWG) {Includes Single wire length and Additional 1% (Sag and wastage)}@ 150 kg/km
3012Eye Hook for earth wire
3013Earth Reel
3014MS Channel Iron: 75x40x6, Length :3300 mm
3015Half clamps: [On Double Pole Dead End structure: 6 No, Double Pole Run Thro" structure: 8 No]
3016Full clamps: [On Double Pole Dead End structure: 4 No, Double Pole Run Thro" structure: 4 No]
3017Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 20 mm F or more(with flat and spring washers)]
3018Barbed wire
3019Danger Plate (203X200X1.6mm)
3020Red Oxide
3021Aluminium Paint
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail