Gun Carriage Factory Jabalpur-GCF has published Tender For Repair/ Replacement Of Internal Point Wiring, Sub-Main Point Wiring Main Panel And Lt Cable Of Bungalows In Upper Line And Chota Rasta Area (Total 32 Nos Bungalows) Gcf Estate Jabalpur.. Submission Date for this Tender is 21-03-2024. Electrification Work Tenders in jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Taking down carefully Copper/Aluminium point wiring, (Light, fan, socket) including fixture and ceiling points, pendent fitting as switches, ceiling rose, pendants, regulators, switches including FTL, high bay lights, material to be store in safe conditionmaterial to be store in safe condition for credit, making good disturb surface. |
2 | M & L ,XLPE insulated, heavy duty, aluminium stranded conductor 1100 volts grade, armoured with galvanized steel wire or tape and over all PVC insulated & sheathedand 3 & 1/2 core, 70 Sq.mm nominal over all PVC cross sectional area. All connection of cables should be carried outas per IE rules & regulations ( with gland and end termination ferrule)and fixingand concealed inwallor as directed by EIC Cable Make : Universal / Havells/Finolex |
3 | M & L ,XLPE insulated, heavy duty, aluminium stranded conductor 1100 volts grade, armoured with galvanized steel wire or tape and over all PVC insulated & sheathedand 4core, 25 Sq.mm nominal over all PVC cross sectional area. All connection of cables should be carried outas per IE rules & regulations ( with gland and end termination ferrule)and fixingand concealed inwallor as directed by EIC Cable Make : Universal / Havells/Finolex |
4 | M & L ,XLPE insulated, heavy duty, aluminium stranded conductor 1100 volts grade, armoured with galvanized steel wire or tape and over all PVC insulated & sheathedand 4 core, 16 Sq.mm nominal over all PVC cross sectional area. All connection of cables should be carried outas per IE rules & regulations ( with gland and end termination ferrule)and fixingand concealed inwallor as directed by EIC Cable Make : Universal / Havells/Finolex |
5 | M & L earth continuity conductor or main earth lead fixed on wall or concealed in wall along with conduit pipe/pipe batten recess or chases buried in ground for loop earthing etc. as required 4.00 mm dia GI wire. |
6 | M&L point wiring of light point /fan point & 5 amps socket bell point , one point controlled by one switch with 1.5 sq mm single core copper stranded conductor, PVC insulated & sheathed cable through PVC conduit of dia 20 mm surface on wallwith all fixing accessories. All connection of should be connected properly as per IE rule. cable make: Finolex/Anchor/Havells/ Universal |
7 | As item No 6 but on same with board for 5 amp socket cable make: Finolex/Anchor/Havells/Universal |
8 | M&L point wiring for telephone wiring. With socket through 1.5 sq mm single cu telephone cable. |
9 | As item no 6 but with 2.5 sq mm single core, copper stranded conductor for 3 pin 6/16 amp ss plug point wiring. |
10 | As item no 6 but with 4 sq mm single core, copper stranded conductor for 3 pin industrial socket for Geyser point wiring |
11 | S&F 3 terminal surface Bakelite ceiling rose of ISI mark size 65 X 55 Mm Make: Havells/Anchore/Roma/C&S |
12 | S&F piano type switch button flush type single pole 250 volts 6 amp ISI mark Make: Havells/ Leader/Anchor/HPL |
13 | M&L piano type Push button flush type single pole 250 volts 5 amp ISI markFor call Bell Make: Havells/ Leader/Anchor/HPL |
14 | S&F single phase 250 volt switch socket combination 6/16 Amp 2 in one shutter type ISI mark, flush type including earth point Make: Havells/Leader/Anchor/HPL |
15 | do as item no 14 but 6 amp 3 pin type Make: Havells/Leader/Anchor/HPL |
16 | S&F single phase call bell 250 volt ISI mark Make: Havells/Leader/Anchor/HPL |
17 | Only fixing ceiling fan and connection with 3 core 1.5 sq mm copper flexible cable , Fan will be provided by GCF |
18 | Only fixing 1 X 20 watt LED TL and connection with 3 core 1.5 sq mm copper flexible cable , LED TL will be provided by GCF |
19 | M &L lamp holder PVC /Polycarbonate type with back plate suitable for batten fitting Make: Havells/Leader/Anchor/HPL |
20 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet as directed by EIC.Make: Havells/Leader/Anchor/HPL |
21 | S& F GI pipe 40 mm dia medium grade laid in ground or fitted on wall /pole with all fixing accessories |
22 | M&L cast iron pressed steel terminal box rectangular in size 75X 75 mm for mounting switches, sockets, fan regulator etc. with 3.00 mm thick white hyluminated sheet over with fixing arrangement |
23 | M&L cast iron pressed steel terminal box rectangular in size 175X 100 mm for mounting switches, sockets, fan regulator etc. with 3.00 mm thick white hyluminated sheet over with fixing arrangement |
24 | M&L cast iron pressed steel terminal box rectangular in size 250 X 300mm for mounting switches, sockets, fan regulator etc. with 3.00 mm thick white hyluminated sheet over with fixing arrangement |
25 | S&F VTPN sheet metalenclosure for fixing of MCCB& MCBs double door,415 volt8 way |
26 | S&F VTPN sheet metalenclosure for fixing of MCCB& MCBs double door,415 volt4 way |
27 | MCCB 415 volt 16 KA,63 amp,4 pole suitable to fix in item no 22 Make : Havells, HPL, Anchor,C&S |
28 | S&F 415 volt, 10 KA, "B" curve miniature circuit breaker (MCB) of 3 pole and 25 To 63 Amp in the MCB DB complete with connecting testing and commissioning Make: Havells/C&S/L&T/Schneider |
29 | S&F SP 6 To 32 Amp , 240 volt , 10 KA "C" curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioningMake: Havells/C&S/L&T/Schneider |
30 | Fixing only and connecting electric meters of 40/60 amp, 3 phase |
31 | S&F Exhaust fan, steel body AC single phase 230 Volt of size 300 mm sweep with blades and frame and louvers Make: Usha/Havells/CG/Bajaj |
32 | S/F, single pole and neutral enclosure with a two pin and earthplug and socket complete with one single pole MCB of 20 amps, 240 volts A.C.MAKE: BAJAJ/ GE Power/ BCH/ MDS |
33 | M & earthing complete with galvanized steel pipeelectrode, 40 mm dia bore medium grade, 2.5 meters in length, buried directly in ground with top edge not less than 1.25 meters below ground level. Connected with earthing lead of 4.00 mm dia GI wire, all as shown in plate no. 2 Earth to be connected with earth test point. All as specified in MES specification including pit chamber with removal type chamber cover. Testing on completion. ER value should be not more than 1 ohm. |
34 | Rough excavation in hard dense soil, exceeding 1.5 M for making earth chamber (0.90X0.90X2.5 M) per earth and getting out soil. |
35 | Excavation of trench in soft soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying underground cable and getting out excavation earth as ordered. |
36 | Supply and laying precast cement concrete cable cover LV type-3 flat size 450mm x180mm x 40mm |
37 | M & L sand filling (River sand) in trench 0.45 M in width and 0.10 M in depth (0.05 M below and 0.05 M over the cable) for providing protection to the cable. |
38 | S&F socket outlet 2 in 1 type flush type 3 pin 5 amp with earth terminal Make: Anchor, Havells, HPL, Roma |
39 | Returning & filling of the excavated soil in trench including leveling, watering and well ramming in layers/ trench spreading. |
40 | Cutting grooves in brick wall 75 mm in width and 65 mm in deep and shaping horizontal/Vertical as required formounting concealed switch boards , making good disturb surfaces of wall with cement mortar and plaster 1:3 as existing wall condition and as directed by EIC |
41 | S& F GI pipe 15 mm dia medium grade laid in ground or fitted on wall /pole with all fixing accessories for earth lead protection pipe |
42 | M&L for boring of Holes under the road, for laying Cable support pipe of 80 mm dia , depth of pipe must be not less than 1 Mtrs from ground level |
43 | S&F cable route indicator dully marked With " LT cable" made of CI plate 6mm thick fixed with MS angle IRON 30 X 30 X 4 mm of length 400 mm long embedded in PCC 1:2:4 type B of Size 150 x150 x 150 mm including necessary workExcavation getting out soft/lose soil Returning filling and removal all as directed |
44 | M & L, cement concrete , Ty B-2, 1 :2:4, 40 mm graded aggregate in foundation and mass concrete in wall / floor or track ,any thickness,size as required including plasters as directed by EIC. |
45 | S&F LED light fitting 1 X 9W/1X 10 W bulk head luminaires including LED light drivers holder connecting up with three core flexible copper conductor cable of suitable sizeMake: Syska/Bajaj/Crompton/Havells |