Tender For Electrification Of New Feeder Mock Up Shop, Rca Shop, Swmf Area And Electrical Works Related To Emccr In Kgs1, kaiga-Karnataka

Nuclear Power Corporation Of India Limited-NPCIL has published Tender For Electrification Of New Feeder Mock Up Shop, Rca Shop, Swmf Area And Electrical Works Related To Emccr In Kgs1. Submission Date for this Tender is 11-04-2024. Electrification Work Tenders in kaiga Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

42760313
Corrigendum : Tender For Electrification Of New Feeder Mock Up Shop, Rca Shop, Swmf Area And Electrical Works Related To Emccr In Kgs1
Open Tender
Indian
Karnataka
kaiga
11-04-2024

Tender Details

Electrification Of New Feeder Mock Up Shop, Rca Shop, Swmf Area And Electrical Works Related To Emccr In Kgs1

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-04-2024
2 01-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-04-2024
3 06-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-04-2024

Key Value

Document Fees
Refer document
EMD
INR 78796.0 /-
Tender Value
INR 39.39 Lakhs /-

BOQ Items

Name of Work: Electrification of New Feeder mock up shop, RCA shop, SWMF area and Electrical works related to EMCCR in KGS1.
Sl. No. Item Description
1Installation & commissioning of different types of lighting fixtures including accessories, of Size:2x2 ft, 1x4 ft, 1x1 ft,NEW or serviced invarious locations including ZONE 2, 3, 4 area.
2Installation of switch boards with switch, socket, fan regulator including power & earthing connections as per field requirement invarious locations including ZONE 2, 3, 4 area.
3Installation of flood lights/ high bay fixtures up to 250 wattsfor indoor /outdoor applications including ZONE 2, 3, 4 area.
4Replacement of old street lighting fixture with New LED type street light
5Installation of SFUs of63 Amps / 125 Amps rating in any area including ZONE 2, 3, 4 area.
6Installation of new ceiling/ wall mounted/ exhaust fans or Re installation of serviced fans including wiring connections
7Discnnection & Removal of faulty ceiling/ Wall mounted/ Exhaust fansfor major maintenance like over hauling.
8Installation of 20/25mm dia 16 SWG rigid ERW GI conduit and accessories. GI conduit, couplers, bends, elbows, round JBs, rectangular JBs, saddles and spacers, ball & sockets, screws, lead rawl plug, check nuts, rubber bushing, GI clamps etc. required for the work shall be supplied by department in any area including ZONE 2, 3, 4 area.
9Installation of16 SWG GI Wire and accessories, GI clamps etc. Required items for the work shall be supplied by department in all areas.
10Installation, termination, connection & testing of single run of 1.5, 2.5, 4.0 Sq. mm. 650/1100V grade PVC insulated copper conductor wire in the conduit installed in any area including ZONE 2, 3, 4 area.
11Installation, terminationconnection & testingof single run of 6/10 sq. mm, 650/1100 V grade PVC insulated Copper/Aluminium wire in the conduit installed in any area including ZONE 2, 3, 4 area..
12Installation & connection of 5/15/20 Amps. Single-phase receptaclesin any area including ZONE 2, 3, 4 area.
13Installation of 63 Amps three phase receptacles in any area including ZONE 2, 3, 4 area.
14Installation, testing & commissioning of lighting panel/other panels of size 680mm x 460mm (Approx). Work includes shifting of panels to the location & handling.
15Installation, testing & commissioning of lighting panel/other panels / Junction box / MCBDBofsize up to 300 x 300mm. (Approx) . Work includes shifting of panels to the location & handling.
16Installation ofPVC casing capping up to 1½” size. Rawl plug and screws required for the work will be issued by the NPCIL. In any area.
17Pulling of 2C/3C/4C flexible PVC cable or 2.5/4 sq. mm Al/Cu wires three runs in casing capping & connection to equipment/ panel/ JB etc. in any area
18Installation of street lighting JB on the wall/pipe support/street light pole by clamping 2mm with 25 x 3 metal strips and completing the work.
19Installation of 26 to 50mm GI pipe. works involves transportation from store, installation on wall/beam in required location.
20Installation of GI flat of 25 x 3mm sizes includes transportation from stores.Cutting of required length.Laying on the wall/beam/on floor chipping /clamping /welding/lugging of GI flat & connecting the bolt & nut as per the site requirement. GI flat / clamp / hardwares will be provided free of cost by NPCIL.
21Installation of GI flat of 50 x 6 mm sizes includes transportation from stores.Cutting of required length.Laying on the wall/beam/on floor chipping / clamping / welding/lugging of GI flat & connecting the bolt & nut as per the site requirement.GI flat / clamp / hardwares will be provided free of cost by NPCIL.
22EXCAVATION OF CABLE TRENCH:-Excavation up to an average of 300mm wide and 400mmdeep cable trench in any type of soil andlaying ofGI/HDPE conduit pipe up to 100 mm dia size. Work alsoincludes Transporting thepipe from main stores, refillingof the trenchwithexcavated soil, leveling thesurface in good looking manner. All as directed by the Engineer-in-charge.
23Laying of following sizepower cables in the already excavated trench / cable tray. upto 40 mm ODcable
24Laying of following sizepower cables in the already excavated trench / cable tray. upto 41 mm to 65 mm ODcable
25Glandingtermination, connection & testing of size up to 38 mmOD armoured /unarmoured cables The required glands/lugs & consumablesforcompletion of work will be given by NPCIL on free of cost.
26Glandingtermination, connection & testing of size uo to 70 OD armoured /unarmoured cables The required glands/lugs & consumablesforcompletion of work will be given by NPCIL on free of cost.
27Installation of street light pole of size 7/9/11 Mtr. at the location shown by the engineer-in-charge. Contractor shall excavate pole pit of size 500mm(Width) x 500mm(Breadth) x 1700mm(Depth) or round shape and install the pole and concrete the pole pit with 1:2:4 20mm and down concrete mixtures including, pole trasportation from stores, shuttering & coping, etc.Installation of JB, cable glanding, connection, fixing of arm top and lighting fixtures as directed by the Engineer-in-charge.
28Removal of street light pole of size 7/9/11 Mtr. Height from the shown location, disconnection of cables, GI flat, GI pipe, removal of JB and dismantling of pole with concrete completely as directed by Engineer-in-charge.
29Attending electrical call duties regularly as per complaint received by different area in plant for EMCCR jobs, Temporory supply arrangment during BSD / plant operationand Carrying out alloted work for 12hrs continuouslyby one skilledworker in all areas including ZONE 2, 3, 4 as per instruction ofEIC.
30Assisting the Departmental personnel of Electrical Maintenance Unit during various maintenance / Unforeseen jobs by providingone semiskilled manpower for 8.00  hrs on continuous basis
31Assisting the Departmental personnel of Electrical Maintenance Unit during various maintenance / Unforeseen jobs by providingone Skilled manpower for 8.00  hrs on continuous basis
32EXCAVATION OF CABLE TRENCH:-Excavation of trench up to an average of 400mm wide and 600mmdeepin any type of soil for laying of various size of cables.The cable shall be covered with bricks of size 9" X 4 1/2" X 3" on three sides of the cable(18Nos. approximate per metre) alongthe length of the cable. The rever sand / M sand shall be spread 100 mm below & above the cable & then bricks shall be placed. The rest of the trench shall be filled with excavated soil.Work alsoincludesleveling thesurface in good looking manner. The supply of bricks & river sand / M sand is in the scope of contractor. All as directed by the Engineer-in-charge.
33InstallationofLT cable route indicators along the route of the cables at an interval asrequiredat Site.The cable routeindicator shallbe drawn from central stores , to be shifted to required location,burried to a minimum depth of 400mm.Thecablerouteindicatorswill be issuedby department.
34Cement conrete coping with finishing in neat manner of size approx as belowfor DBs, Route indicators, cable supports, pipe supports as instructed by EIC.Coping Size 0.2 x 0.4 x 0.2 mtrs approx.
35Excavation of cable trench in any type of soil including laterite for removing of damaged / faulty cables.After removal &rectification of the cable, trench has to be backfilled and leveled In neat manner.
36Cable laying of power cable3.5C x 400 sq mm from contruction DG building to RCA shop and New Feeder shop Andbetween PDB1 (RCA shop) & PDB2 (new feeder shop ) in trench/ pipe as per field routing.
37Disconnection & removal of old PDB installed in RCA shop. Work includes disconnection of all power, control and earthing connections, removal cable glands, cutting & removal bas / side frames, Lifting and shifting of removed panel to shop / stores as directed by EIC.
38Errection & commisioning of New MCC/ PDB of size 2500x2100x400 mm approx. Work includesLifting and shifting of new panel from main stores up to location, installation of panel on base frame, levelling and errection, power / control & earthing connections, testing and charging the panel incomer and all outgoing feedersas directed by EIC.
39Errection & commsioning of New PDB/ LDB of Size 1400x2100x350 mm appox. Work includesLifting and shifting of new panel from main stores up to location, installation of panel on base frame, levelling and errection, power / control & earthing connections, testing and charging the panel incomer and all outgoing feedersas directed by EIC.
40Street light pole painting. Includes surface preparation by cleaning, applying one coat primer & two coats of aluminum paint for pole, arm and JB/CG box complete. Supply of paint coverd in item sl no 54.
41Supply of Modular type Switch board consisting 2 switches of 6 Amps+ 2sockets of 6 Amps surface type.
42Supply of Modular type Switch board, 4 switches of 6 Amps+ 2sockets of of 6 Amps. surface type
43Supply of SP switch 6 Amps, 230 volts, Modular type
44Supply of Socket 6 amps Amps, 230 volts, Modular type
45Supply of fan regulator, Two module size,230 volts, step type
46Supply of 5 in 1 combination box with 6 amps switch and 6 A socket
47Supply of 5 in 1 combination box, 16 amps, switch, 16 A socket with indicator
48Supply of LED fixture, 2x2 size, false ceiling mounting, 36 watts, 230 volts,
49Supply of LED fixture, 1x4 size, false ceiling mounting, 36 watts, 230 volts,
50Supply of LED fixture, 1x1 size, false ceiling mounting, 18 watts, 230 volts,
51Supply of Ceiling fan, 1200 mm sweep,BLDC type, with accessories &remote for speed control.
52Supply of GI flat, 25x3 mm size, hot dip galvanised, for earthing of electrical equipment
53Supply of GI flat, 50x6 mm size, hot dip galvanised for earthing of electrical equipment
54Supply of Aluminum plaint for streetlight painting
55Supply of primer for streetlight painting
56Supply of Metal putty for street light pole
57Supply of 16 SWG GI wire for earthing connections
58Supply of Cable Glands, Double compression type, Weather proof, Made of Brass and duly Nickle plated, Suitable forarmoured cables up to 20mm OD size. Entry thread BS cond. size - ¾-1’’.
59Supply of Cable Glands, Double compression type, Weather proof, Made of Brass and duly Nickle plated, Suitable forarmoured cables up to 30mm OD size. Entry thread BS cond. size - 1-11/4’’.
60Supply of solar street light, 30 watts LED, 75 w PV module, 30 AH battery with 6 mtr pole
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail