| 1 | Supply, erection and testing in repair of ISI markedM.S. pipes (Class B) and specials etc. (as per IS:1239) forlaying above groundfor hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing / erection of pipes with suitable flat/angle iron including specials i.e. bends, tees, reducers, flanges etc. in proper position including all supports as per layout, including hangers for sprinkler piping, jointing by welding, aligning the pipe line, painting with a red oxide primer coat and two coats of synthetic enamel paint fire red colour, providing tapping for pressure gauges and for other instruments etc including taking down old unsv MS Pipe. complete as per drawings, as specified and directed for the following sizes :-NOTE:- (i) The quoted rates shall also include for making holes in masonry/ RCC slab, wall, chases in wall etc. &making good the same to original conditions.(ii) Upto 40 mm dia. pipe threaded forged fittings and threaded joints shall be provided and for 50 mm dia. and above pipes welded joints with MS fittings shall be provided which shall be deemed to be included in the unit rates quoted by contractor. |
| 2 | (a) 25 mm nominal bore |
| 3 | (c) 40 mm nominal bore |
| 4 | (d) 50 mm nominal bore |
| 5 | (e) 65 mm nominal bore |
| 6 | (f) 80 mm nominal bore |
| 7 | (g) 100 mm nominal bore |
| 8 | (h) 150 mm nominal bore |
| 9 | Supply & installation in repair of ISI marked63 mm dia, Hydrant Valve SS, flanged inlet with 63 mm female instantaneous outlet confirming to IS : 5290 on the fire wet riser/down comer including making 80 NB pipe connection with riser fixing the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. testing the hydrant including taking down old unsv hydrant and completing the work in all respect all as specified and directed. (MAKE : Firex / Safex / Minimax / Newage) |
| 10 | Single headed |
| 11 | Doubleheaded |
| 12 | Supply, fixing, testing & commissioning in repair of 20 mm bore and 30 meter long hose (Rubber lined dunlop pipe) and hose reel for first aid fire fighting conforming to IS : 884, with full swing drum, fixing brackets, 5 mm dia. shut off SSnozzle, 32 mm dia. hand lever operated ball valve, connecting directly from the riser through 32 mm dia. G.I.pipe with sockets, elbows, nipples etc. including providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings, all as specified and directed. |
| 13 | Supplying and fixingin repair of SSISI marked 63 MM. dia. Instantaneous pattern short branch pipes & 16 mm dia. Nozzle suitable for inter connections to hose pipe coupling as required complete all as specified and directed. (MAKE : Minimax / Firex / Safex / Newage) |
| 14 | Materail and Labour in repair ISI marked RRL (IS : 636 type-II) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) SSmale and female coupling complete as required all as specified and directed. |
| 15 | Supplying and fixing in repair brass orifice plates at appropriate places to restrict the pressure up to 3.5 Kg/ Cm2 at different floors on the wet riser system and yard hydrant. It shall be inserted between the tee and hydrant valve. The size of plate being 100 mm or 80 mm (as the case may be), the hole not less than 50 mm. and the thickness shall not be less than 6 mm complete all as specified and directed. |
| 16 | Supplying and fixing in repair 25 mm dia air release valve , flanges / union, suitable for sprinkler / wet riser / down comer system with all necessary connections complete in all respects, all as specified and directed. |
| 17 | Supply, fixing, testing & commissioning in repair of installationyard hydrant post/stand post 80 mm Dia GI/MS both flanged type 1.5 RMheightcomplete all as specified and directed. |
| 18 | Supply, fixing, testing & commisioningin repair Sprinklers comprises of 15mm dia conventional pattern, 68 Degree Centigrade , quatzoid bulb type pendent sprinklers. The installation shall be complete as per the drawings and requirement of local fire service & as specified and directed. (MAKE : Spray safex / HD/ or equivalent make as specified by GE) |
| 19 | Sprinklers rossette |
| 20 | sprinkler flexible drop 1m |
| 21 | Disconnecting/ dismantling ,Suppply and fix as in repair Hose box made of 18 gauge MS Sheet 1200mm X 900mm X 450mm. with doubledoor with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted with power coated paint fire red on external /internal surfaces and fixed on floor/ wall of blgincluding dismantlingcomplete all as specified and as directed by Engr-in-Charge. |
| 22 | . Supplying, fixing, testing and commissioning in repair oflisted andapproved and as per IS standards automatic fire Alarm detectors if following types including end of line relay bases whereever required as per specifications including making connections with wires to complete the system :- (MAKE : System Sensor / Apollo / Edward) |
| 23 | (a) Optical/Photoelectric type smoke detectors as per IS : 11360 - 1985 of photo-optic sensing chamber, 12/24 volt D.C., twin visual alarm indicator \"Blink\" in stand by and \"Steady\" in alarm(LED\"s) complete in all respectswith baseas required , all as specified and directed. |
| 24 | (b) Fixed cum rate of rise temprature typeheat detectors as per IS : 2175 - 1988, 57 to 60oC (135oF.) (fixed) and 15oF per minute rate of rise twin visual alarm indicators (LED\"s) \"Blink\" in stand by and \"Steady\" in alarm complete in all respects with base as required, all as specified and directed. |
| 25 | (c) Projected Beam smoke detector with protection range upto 100 meter operating temperature of -22oF to +131oF, caliberated test filter, alarm indicator (local red LED), trouble indicator (local amber LED), normal indicator (local flashing green LED), alignment LED etc., all as specified and directed. |
| 26 | Supplying, fixing, testing and commissioning in repair of manual call points break glass type housed in 16 SWG sheet steel housingin surface/recess including making connections with wires complete in all respects and as per specifications. The manual call point should have an indicator, which should\"blink\" in stand by condition. (Make:MPA/ASC/ or equivalent make as specified by GE), all as specified and directed. |
| 27 | Supplying, fixing, testing and commissioning in repair of electronic hooters (hooters shall also be able to work as public address system sounders) housed in 16 SWG sheet steel housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications and directed. |
| 28 | Supplying ,fixing,testing and commissioning in repair of response indicators pulsating type suitable for operation on 12/24 volts D.C., housed in 16 SWG sheet steel housing suitable for surface/recess mounting including making connections with wires complete in all respects and as per specifications. The response indicator should have an indicator, which should \"blink\" in stand by condition complete all as specified and directed. |
| 29 | Supplying , fixing, testing and commissioning in repair of ISI marked 2 core 1.5 sqmm PVC insulated Armoured stranded copper conductor cable conforming to IS : 1554 specifications on existing cable tray / rack or fixing on wall/ ceiling with iron clamps or inside existing pipe complete in all respect including end termination, glands, lugs & clamps etc., complete all as specified and directed. |
| 30 | S&F in repair Concealed or open 20mm external dia. Rigid non metallic PVC conduit with and including alltees, bends, elbows, reducers, bell mouth tube ends, junctions and terminal boxes andfixing accessories such as couplers, lock nuts, saddles, pipe hook, etc for fire alarm wires complete all as specified and directed. (Cutting chases shall not be measured separately and shall be deemed to be included in unit rate quoted by the contractor against Sch \"A\" Part I(Building Work)). |
| 31 | Supplying and fixing in repair of self illuminated \"EXIT\" signs made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed to the walls as required and as directed at site complete all as specified and directed. |
| 32 | Supply & fixing in repair in position ISI marked nominal borecast ironValves, Sluice, flanged150 mm of class 1.6 PNIS - 14846, suitable for pressure 15 KG/cm2 including transporting to worksite, supply & fixing nuts, bolts, gaskets, flanges & washers etc. including testing, taking down old unsv, complete all as specified & directed. (MAKE :- KIRLOSKAR /ZALOTO / or equivalent make as specified by GE) |
| 33 | Supply & fixing in repair in position ISI marked 150 mm nominal bore cast iron double flanged Non Return Valves as per IS : 5312, part- I, suitable for pressure 15 KG/cm2, including transportation to worksite, supply &fixing nuts, bolts, gaskets and washers etc. complete including testing all as specified and directed. |
| 34 | Supply, installation and testing in repair of cylindrical type flanged airvessel tank, 450 mm dia, 1.0 m long and made out of 6 mm thick M.S. plain black sheet, including necessary welding or riveting as directed, common for all pump sets including flanged connection, suitable supporting legs etc. The air cushion tank shall be provided with stop cock, safety valve, pressure gauge, drain valve, provisions for pressure switches, tested to min 15 KG/cm2including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 35 | Supply & installation in repair of 4 way 63 mm instantaneous inlet for fire brigade connection and making connection with 150 NB fire fighting wet riser pipe or under ground water tank and fixing inlets with caps and chains in a 4 mm thick glass fronted box of 16 SWG MS sheet, fixing it on the ground level on concrete base or on MS Angle Iron frame, painting with two coats fire red paints over primer coat, completing the work in all respect complete including testing all as specified and directed.(MAKE : Firex / Safex / Minimax / Newage) |
| 36 | Supplying and fixing in repair of Draw out connection in Under ground water storage tankwith 150 mm dia. medium grade GI pipe of required length, suction coupling in conformity with local regulations complete in all respects all as specifed and directed. |
| 37 | Supplying and fixing in repair of copper strainer at the suction pipes of 150 mm nominal borefire pumps complete all as specified and directed. |
| 38 | Supply & Fixing in repair weather proof standard fire hose cabinet (900 mm x 900 mm x 600 mm) outdoor type suitable for accomodating single headed hydrant valve made of not less than 16 SWG MS sheet having central opening glassed door (4 mm thick clear glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on suitable raised brick masonry built in CM (1:6) platform or on MS Angle iron frame of suitable size and section as desired complete all as specified and directed. The words \"FIRE HOSE\" to be painted on the box. |
| 39 | M&L Construction of brick masonry valve pit of size 120x120x120cm (internal dimension) of sub class \"B\" brick built in cement mortar (1:4) on 200 mm thick PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in bedding and coping, 15 cm thick cement platering in cm (1:4) internally and externally upto 15 cm below ground level and providing valve pit cover with 3mm thick MS sheet welded with 40 x 40 x6 mm angle iron frame fixed on top surface of pit wall on edge of the cover and hinged in one side and providing locking arrangement including complete painting of the corner with two coas of synthetic enamel over one coat of red oxide primer all as specified and directed. |
| 40 | Supplyingand laying in repair of ISI marked 25 Sqmm 4 core Aluminium conductor, XLPE insulated, armoured, served, sheathed Cable 1100 V grade with terminal joints by palm or pin typecable sockets (lugs), insulating with tapes, double compression type brass and nickle plated compression glands. On surface, the cable run shall be on MS cable trey or fixed on M.S. clamps etc.of suitable size or as directed complete in all respects, as specified and directed. In case Cable is laid in trenches Excvation and earthwork, Sand cushioning and brick protection shall be measured and paid separately) |
| 41 | Material and labour in repair for F/F point wiring with copper conductor from Ground floor to Top Flore forMCP/Hooter/Control Pannel Board(Control panel Board to Each MCP located at Each flore and hooter)including appropriate size of PVC casing capping/PVC Conduit with all accessoriese for surface/concealed wiring as per existing including 2x1.5 sq. mm + earth wire 1.5 sqmm PVC insulated copper cable 1100 Volts grade.( PVC conduit will measured and paid separately) |
| 42 | S & F in repair of Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugsof size up to 200mm dia all as specifeid and described. |
| 43 | Supply and fix in repair of Valve, butterfly conforming to IS 13095, 80 dia |
| 44 | Supply and fix in repair of Valve, butterfly conforming to IS 13095, 100 dia |
| 45 | Supply and fix in repair of Valve, butterfly conforming to IS 13095, 150 dia |
| 46 | M&L in repair of Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zinc Chrome and two coats of synthetic enamel paint all as specified and directed. |
| 47 | Supply and fix in repair of nozzlemade of SS 63 mminlet and 16 to 20 mm dia shut off outlet diaall as specified and as directed . |
| 48 | Cutting existing 150mm MS pipe line and fixing of any type of fitting for connecting new pipe line complete all as specified and directed |
| 49 | Excavation in trenhes not exc 1.5 m in depth and not exc 1.5 m wide for taking out/ laying CI/GI/DI pipes and getting out in soft/loose soil complete all as specified and directed |
| 50 | M&L for cutting road, concrete surface for laying of DI/MS pipe and making good of distributed surface complete all as specified and directed. |
| 51 | Removing excavated soil at a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 52 | Returning,filling in including spreading, leveling, watering and well rumming in layers not exc 25 cm complete all as specified and directed. |
| 53 | Taking up ductile iron water mains (including all fittings) of any description of pipe for cleaning/ removing deposited mud, sludge etc including burning out joints and recovering lead or gasket joint for pipes of following size : |
| 54 | (a) DI pipe150 mm bore size |
| 55 | (b) DI pipe100 mm bore size |
| 56 | (C) DI pipe80 mm bore size |
| 57 | Supply and laying centrifugally cast (spun) Ductile iron pressure pipes with double flanged end, class K-7conforming to IS-8329/2000 (latest revision) with inside cement mortar lining and metalic zinc coating and outside black bitumen coating and having portland cement properties suitable for gasket joints including suitable size of rubber gasket, nuts, bolts and washer but excluding specials complete all as specified and directed by Engr-in-Charge.completing the work in all respect as per drawings, as specified ans directed for the following sizes :- |
| 58 | (a) 80 mm nominal bore |
| 59 | (b) 100 mm nominal bore |
| 60 | (c) 150 mm nominal bore |
| 61 | Material and labour,for repair / replacement of worn out Gland Packing of pump set / sluice valves / hydrantsany make / metal / sizeincludingwashers of any shape / sizeto avoid water leakage as indicatedincluding taking out old one complete all as specified and directed. |
| 62 | Dismantling ,Servicing of allmultisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer\"s instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and directed . |
| 63 | Supplu and fix PA/Speaker 150mm Dia PVC6 Wall as specified and directed |
| 64 | Supply, Installation Testing Commissioning in repair of Networkable Analogue Addressable Fire Alam Control Panel. The Panel Shall be compliant with EN54-4 and approved by LPCB. The Fire Alarm control Panel should have 4 loops & shall have expandable capacity to 8/ loops. The panel must have full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The panel must also have the capability to take addressable intelligent wire and wireless devices on same loop. Each loop shall have a capacity of 127 analogue addressable devices and 127 base sounders/Base sounder beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The panel shall have three access levels. Panel Shall support filterable and printable. The panel shall have three access levels, Panel shall support upto 500 cause & Effects entries, with upto 20,000 inputs controlling & 20,000 controlling outputs across the network. The panel shall have capability for peer to peer networking through Rs 485 network card. The panel must have 4 inbult programmable sounder circuits, each circuits rated at 2.5A . The panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The panel shall have up to sub-addressable 512 programmable inputs/outputs via optional Rs 485 COMMS serially connected expansion cards. The panel shall have 240V AC power supply alongwith automatic Battery Charger. The panel shall be fully expandable via common plug in loop driver boards, The user shall have a choice of using the panel with 5.25 Amp o 10.25 Amp power supply unit which is inbult in the FACP and should be approved to EN54-4. The panel shall have configurable via USB port to PC or memory stick. The panel shall have dedicated Rs 232 serial port for optional printer. Including taking down old unsv panel. Approved by EN54.(Make Model No.Latitude 4 Loop EN54 Hochiki/ or equivalent make as specified by GE) |