| 1 | (Supply & Erection) |
| 2 | Erection of 11.0mtrs length ofSteel Tubular Pole at any kind of soil upto a depth of 1/6 th of pole height, includingexcavation of earth,refilling the pit withwith soilupto the ground level, ramming and making complete in all respect. |
| 3 | Erection of 9.0mtrs length ofSteel Tubular Pole at any kind of soil upto a depth of 1/6 th of pole height, includingexcavation of earth,refilling the pit withwith soilupto the ground level, ramming and making complete in all respect. |
| 4 | Erection of 8.0mtrs length ofSteel Tubular Pole at any kind of soil upto a depth of 1/6 th of pole height, includingexcavation of earth,refilling the pit withwith soilupto the ground level, ramming and making complete in all respect. |
| 5 | Erection of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp,Nuts & Bolts etc. as required. and making complete in all respect. |
| 6 | Erection of M.S.Angle Cross-Arm,1.0 to 2.8 mtr Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts) |
| 7 | Erection of M.S.Angle Cross-Arm bracket for LT Line upto 1.2 mtr long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts) |
| 8 | Erection of M.S.Channel Cross-Arm,0.3 to 1.2 mtr Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts) |
| 9 | Erection of M.S.Channel Cross-Arm,1.3 to 2.8 mtr Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts) |
| 10 | Erection of M.S.Channel Cross-Arm,0.6 to 2.8 mtr Long100 x50 x 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts) |
| 11 | Earthing with G.I pipe 2.5 mtr Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing including supply of G.I.Pipe,Salt & Charcoal, GI wire, nuts &bolts, etc. as required) |
| 12 | Erection of 11KV Pin insulator along with Pin. |
| 13 | Erection of 11 KV Single Disc insulator set along with necessary fittings |
| 14 | Laying & Stringing of 1km (Single Conductor) ACSR 6/1/2.59 mm dia \"WEASEL\" including hoisting & binding etc. Complete as required. |
| 15 | Laying & Stringing of 1km (Single Conductor) ACSR 6/1/3.35 mm dia \"RABBIT\" including hoisting & binding etc. Complete as required. |
| 16 | Febrication of Cross-Armsby MS Channel/MS Angle as per specification |
| 17 | Installation/Positioningof 11/0.430KV,3-Phase 63 KVA of Distribution Transformer on Polewith necessary connections & fitting fixing of all allied accessories components asrequired for making complete in all respect for energizing. |
| 18 | Erection of 9KV,5KA single pole metal oxide gapless type LA , including necessary connection complete as per technical specification. |
| 19 | Erection of 11KV DOF unit set of three nos.including necessary connection complete as per technical specification.(Excluding the cost of back clamp,Nuts & Bolts) |
| 20 | Erection of 11KV 200 Amp. GOS unit set of three nos.including necessary connection complete as per technical specification (Excluding the cost of back clamp,Nuts & Bolts) |
| 21 | Laying of one number PVC insulated and PVC sheathed / 70 sqmm XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.....Trench Size: Width-350mm, Hieght-1200mm / Sand (couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks. (Upto 120 sq. mm Cable) |
| 22 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required…….Trench Size: Width-350mm, Hieght-1200mm / Sand (couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks(Upto 120 sq. mm) |
| 23 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of all size in theGI Pipe/HDPE for riser including tieup of Pipe with pole by the help MS Flat Clamp (excluding cost of Clamp and Nut&Bolts) as required ( Up to400 sq. mm ) including coiling of excess cable. |
| 24 | Supply , Making and Erection of Out door cable end termination with heat shrinkable jointing kit completing with all accessories i/c lugs suitable following size of 3 core XLPE alluminium conductor cable 11 KV Grade as required upto 150 Sqmm. |
| 25 | Providing of Pre-castcement concretecable identification route markerof T shape (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed \"DANGERS: TSECL, ELECTRIC POWER CABLE\" with Black colour letter(both side). The visible part shall be painted with Yellow colour japan paint. (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits. |
| 26 | Providing Three Phase Service Connection with laying of PVC cable from nearby Electrical pole to Premises upto 35mtr in length supported by G.I.Wire,Reel Insulator i/c fitting fixing of Energy Meter as required . |
| 27 | Maintaining adequate clearance from overhead liveconductors by Trimming of tree branches for Way Leaves |
| 28 | Grouting of steel tubuler poles /stay set with CC of ratio 1:2:4(1 cement : 2 river sand : 4 Jhama brick aggregate of 20 mm nominal size)i/c supply of cement,sandand brick aggregate20 mm nominal size complete with excavation, refilling of earth ,ramming alonf with centeringand shutteringaas required @ 0.273 CUM per Steel tubulerpole & & 0.119 Cum/stay sets per TSECL specification,27 nos.S.T Pole (0.273 Cum X27=7.371 Cum) |
| 29 | Applying paints with ready mixed primer of approved primer of approved quality on steel works including painting ( two or more coats ) with alluminium paint of approved quality to new works to given an even shade( As per approved agreement no. DGM/ED-II/2022-23/02Dt. 12-05-2022 |
| 30 | Providing of Sub-station protective fencing as per direction of Engineer -In-Charge. |
| 31 | Carriage of 11.0 mtrslength of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store ( Ambassa Electrical Division ) to working site Vis-a-vis, including loading, unloading and stacking as required,Upto the lead range 25 km of Maximum 8 (Eight ) nos. of Pole ii) Beyond 8 (Eight )nos Pole |
| 32 | Carriage of 8.0 / 9.0 mtrslength of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Storeto working site Vis-a-vis, including loading, unloading and stacking as required,Upto the lead range 25 km ofi)Maximum 6 ( Six ) nos. of Poleii) Beyond 6 (Six ) nos Pole |
| 33 | Carriage of materials such as Cable,AAC, AAAC, ACSR, G.I.Wire,Cross-Arm,Stay set,Insulators etc., by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, upto the lead of 25km & 50km,Upto the lead range 25 km |
| 34 | Carriage of G.O.S, D.O.F,L.A,etc., by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required ,Upto the lead range 25 km |
| 35 | Carriage of11/0.430, 3-Phase ,63 KVA by Mechanical Transport from the Site /Store/Worshop to working site Vis-a-visincluding loading, unloading and placing on base, as required,Upto the lead range 25 km |
| 36 | Supply of 3-phase 3-core, 6.35/11 KV ,70sqmmXLPE insulated Aluminium power cable |
| 37 | Supply of 110 mm dia minimum 6.5 mm , maximum 7.3 mm wall thickness HDPE Pipe |
| 38 | Supply of 70 Sqmm Alluminium Lugs |
| 39 | Supply of 120 Sqmm Alluminium Lugs |
| 40 | Supply of Wooden Plank (24\"X10\"X1.5\"size) including necessary connection etc. as required |
| 41 | Copper Plate with holes for connection of L.T Side cable at Transformer |
| 42 | Supply of Polythene Pipe 1/2\" dia |
| 43 | Supply of Fabricated MS Bracket Clamp |
| 44 | Supply of Fabricated MS Stay Clamp |