Tender For Soil Investigation For Provision Of 08 X Officers 16 X Jcos And 48 X Ors Against Defi Of Md Accommodation At Fazilka Mil Station, abohar-Punjab

Military Engineer Services-MES has published Tender For Soil Investigation For Provision Of 08 X Officers 16 X Jcos And 48 X Ors Against Defi Of Md Accommodation At Fazilka Mil Station. Submission Date for this Tender is 23-03-2024. Soil Survey Tenders in abohar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42707921
Corrigendum : Tender For Soil Investigation For Provision Of 08 X Officers 16 X Jcos And 48 X Ors Against Defi Of Md Accommodation At Fazilka Mil Station
Open Tender
Indian
Punjab
abohar
23-03-2024

Tender Details

Tender For Soil Investigation For Provision Of 08 X Officers 16 X Jcos And 48 X Ors Against Defi Of Md Accommodation At Fazilka Mil Station

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-03-2024

Key Value

Document Fees
Refer document
EMD
INR 3780.0 /-
Tender Value
INR 1.89 Lakhs /-

BOQ Items

Name of Work: SOIL INVESTIGATION FOR PROVN OF 08 X OFFICERS, 16 X JCOs AND 48 X ORs AGAINST DEFI OF MD ACCN AT FAZILKA MILSTN
Sl. No. Item Description
1Bore hole dia shall be 150mm. depth of bore shall be decided as per the site condition and may be taken 15 m for N value reaches 50, whichever is earlier. Note : Under this test preferably following results to be provided : (i) Grain size analysis, identification & classification of soil. (ii) Unit weight (bulk density), natural moisture content, liquid limit , plastic limit, Shrinkage limit, Plasticity index, specific gravity. (iii) Dry density, degree of saturation of soil. (iv) Free swelling index & swelling pressure if expansive soil is encountered. (v) Shear parameters (C-Ø analysis). (vi) Consolidation test & Permeability test. (vii) Depth of water table below ground level. (viii) Presence of loose soil, if any and its depth. (ix) If weak soil with lesser N value as specified in table-1 of IS 1893 (Part-I) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (x) SPT test shall be done at 1.0 m interval. (xi) Reccomendation for filling under floor and filling under protection including plinth protection. (xii)Recommendation of SBC at different depth of foundation 1.2m, 1.5m, 1.8m, 2.0m and 2.5m for each building and/or most suitable strata depth for resting foundation as per type of building/Soil investigation details. SBC and its calculation based on N value, shear strength and settlement criteria SBC to be given for following Size 1.2m x1.2m ,1.5m x 1.5m, 2m x 2m, 2.5m x 2.5m, SBC values shall be calculated based on C-Øanalysis as well as SPT value. For calculation formula given in IS 6403 shall be used. (xiii) if pile foundation are required the depth of pile shall be mentioned and pile capacity in compression, uplift & lateral load shall be given for 300, 400, 450, 500 dia for underreamed piles & for 450, 500, 550, 600 mm dia for long piles. (xiv)Recommendations regarding type of foundaion to be adopted & net SBC/pile capacity to be adopted. Also, recommendation shall be given regarding stability of soil and soil stabilisation required, if any (xv) Borehole position duly marked on plan and their distances from adjacent prominet reference points. Plan size of bldgs shall also be marked in the plan. This plan shall be signed by GE,AGE & soil consultant.(xvi) Undisturbed soil sample shall be collected at 1.0 m interval and at change of strata. K-value of soil 0.5 m depth required in case of swimming pool and water retaining structure. Modulus of subgrade reaction , Direct shear test on dusturbed soil sample(xvii) Submission of report in sextriplicate. Note : Colour photograph A4 size paper of the site with the locations of the boreholes duly fiagged should be submitted. The photograph should also preferably include any reference structure and ttheeh identification of the same be marked.
2Chemical analysis of soil and recommendation and type of cement to be used for RCC foundation complete all as specifed and directed by Engr-in-Charge
3Chemical analysis of ground water (water to be obtained from bottom of bore hole), complete all as specified and direct by Engr-in-Charge.