Tender For Additional / Alternator Works To Building No P-38 And P-39 Of Asc Supply Type C At Nams Under Ge Nams, Amritsar-Punjab

Military Engineer Services-MES has published Tender For Additional / Alternator Works To Building No P-38 And P-39 Of Asc Supply Type C At Nams Under Ge Nams. Submission Date for this Tender is 25-03-2024. Mobile Generator Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42706662
Corrigendum : Tender For Additional / Alternator Works To Building No P-38 And P-39 Of Asc Supply Type C At Nams Under Ge Nams
Open Tender
Indian
Punjab
Amritsar
25-03-2024

Tender Details

Additional / Alternator Works To Building No P-38 And P-39 Of Asc Supply Type C At Nams Under Ge Nams

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 54000.0 /-
Tender Value
INR 27 Lakhs /-

BOQ Items

Name of Work :ADDN / ALTN WKS TO BLDG NO P-38 AND P-39 OF ASC SUPPLY TYPE C AT NAMS UNDER GE NAMS
Sl. No. Item Description
1Material and labour for cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and removing rubbish not exc. 50m complete, all as specified and directed.
2Taking down aluminium Chowkats or frames from the opening of sizeexceeding 1.5 Sqm but n exc 4 Sqm each with shutters ( without taking off shutters from the frames) complete, all as specified and directed.
3Taking down steel window of any size n exc 1.50 Sqm each( without taking off shutters from the frames)complete, all as specified and directed.
4Taking down steel ventilator ofsize n exc 1.50 Sqm each( without taking off shutters from the frames)complete, all as specified and directed.
5Taking down steel rolling shutter of size exc 2.0 sqm each of any description complete, all as specified and directed.
6Dismantlingof brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete, all as specified and directed.
7Material and labour for brick work with sub class "B" bricks straight curved on plan exc 6 mean radius built in cement mortar 1:6 complete, all as specified and directed.
8All as per Srl item No 07above but except bricks (old dismantled serviceable bricks obtained from Item No 06 to be used) complete, all as specified and directed.
9Taking down cement plaster of any description on brickwalls, etc including raking out joints, hacking for key scrubbing down with water etc complete, all as specified and directed.
10Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:6. finishing even and smooth without using extracement complete, all as specified and directed.
11Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in cement mortar 1:4. finishingb the surfaces even and fair without using extra cement complete, all as specified and directed.
12Material and labour for preparation of new surface andapplying two coats of oil bound distemper on walls including one coat of primer complete, all as specified and directed.
13Material and labour for preparation / complete removal of existiong treatment of old decorated surfaces plastered or un plastered of walls and applying one coat of oil bound distemper on wall . complete removal of existing treatment complete, all as specified and directed.
14Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade company depot tinted with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10sqm over new surface/ after prepairing old surface complete, all as specified and directed.
15Material and labour for preparation new /old surfaces plastered or un plastered of ceiling and applying one coat of oil bound distemper on ceiling . complete, all as specified and directed.
16Supply and fix powder coatedaluminium frame for doors ,windows, ventilators with one or more rebates including joining cleats for fixing complete, all as specified and directed. ( Minimum thickness of powder coating 50 micron)
17Supply and fixing aluminiumpowder coated shutter(for doors) wighing 0.55 kg/mincluding necessary joining cleats,glazing clips, rubberbeading with neoprene packing anodized handle 2 numbers in each, locking arrangement (mortised) and aluminuium anodised tower bolt 200 mm long aluminium snap beading screws etc. complete, all as specified and directed.
18Supply and fixing aluminiumpowder coated shutter(for window and ventilator) side hung type without sash, aluminium section wighing 0.55 kg/mincluding necessary jointing cleats,glazing clips, rubberpacking, anodised aluminium snap beading, screws, anodised aluminium fitting such as peg stays 150mm long (1 no.) hinges type B-21 100mm long( 2 no) suitable handle (1 no) complete, all as specified and directed.
19Supply and fix Sheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading with and including solar control film 25 Micron reflective type sticked to glass panes as per instructions of manufacturer complete, all as specified and directed.
20Material and labour for Vitrified tiles,dark shade 10mm thick (Square/ rectangular) polished, area of each tiles n.exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6.including dismantling existing treatment or roughening the surface by hacking/punching complete, all as specified and directed.
21Material and labour for providing and fixing Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre and to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
22Material and labour for providing and fixingof gypsum board 12mm thick on ceiling fixedwith screws as per manufacturer is instructions complete, all as specified and directed.
23Supply and fixing hollow PVC Wall Liningconsisting of5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on and including PVC frame as per manufacturer"s specifications complete, all as specified and directed.
24Material and labour for applying 2mm thick wall care putty on ceiling complete, all as specified and directed.
25M&L for Machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and no pigments over and including 25mm thick sand cushioning 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor complete all as specified and directed.make
26Surface excavation n exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete, all as specified and directed.
27Material and labour Hardcore ofbroken bricks, gauge n exc. 63 mm, deposited , spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete, all as specified and directed.
28Supply and fixing of MS framed work as in framed for cladding,glazing etc of angle or other section with gusset plates, rail, braces,etc and similar work including primer conform-ing to Fe-290 (Gde E-165) complete, all as specified and directed.
29Material and labour for RCC nominal mix type B-1 (1:2:4) (20mm graded stones aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete, all as specified and directed.
30Material and labour for form work to fair finished flat surfaces of sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilever,shelves, including supports, overhangs etc also splays between floors and beams etc complete, all as specified and directed.
31Supply and fixing mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or scouring with clips complete, all as specified and directed.
32Supply and fixing mild steel TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or scouring with clips complete, all as specified and directed.
33Material and labour two coats of synthetic enamel paint over a priming coat of red oxide including prepration of surfaces on steel surfaces of any description over 10 cm in width or girth not otherwise described complete, all as specified and directed.
34Material and labour of Wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, multistranded with copper conductors conforming to IS specifications,drawn through and including conceled conduitconcealed/ fixed on wall / ceiling with suitable clamps, screws, etc or concealed in wall including terminal boxes fabricated with 1.6 mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc, including provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly complete, all as specified and directed. :-
35One light point/Bell/Fan point controlled by one switch.
36One socket outlet 5 pin 6 Amp controlled by one, one way switch on same board.
37One socket outlet 5 pin 6 Amp controlled by one, one way switch on independentboard.
38All as per item No. 30 here-in-before but wiring with using cable 2.5 sqmm size copper wire (FR) and earth wire of PVC insulated (Green colour) 2.5 Sqmm sizecopperwire for one 6 pin socket outlet, 16 Amp on independent board complete, all as specified and directed.
39Supply and fix switch piano one way 6 Amp, SP, 230 Volts complete, all as specified and directed.
40Supply and fix stepped type electronic fan regulator, flush type, complete, all as specified and directed.
41Supply and fixing ceiling rose surface bakelite3 terminals 65x32mm complete, all as specified and directed.
42Supply and fixingLamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant/batten fittings including LED bulb 9 Watt, 230 Volt complete, all as specified and directed.
43Supply and fixingLED 2 X 2 ultra slip recess mountedluminaire with high brightness 36 Watt LED packageand Unique pattern acrylic de-glaring diffuser sheet for glare-free uniform light distribution suitable forceiling icluding making electrical connections complete, all as specified and directed.
44Supply and fix wall/ceing mounting LED 18 WattPC Diffuser tube light fitting complet with all aceesories 1x18W LED suitable for domestic application 240Volts 50HZ including one tube rode and internally pre-wired with 1.5 sqmm twin twisted flexible copper conductor and complete, all as specified and directed.
45Material and labour for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 6sqmm including 1 run of 6 sq mmsingle core multistranded copper conductor,PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring complete, all as specified and directed. Note :2 Run of 6 sqmm, 1 Run of 6 sq mm and 1 run of PVC conduit will bemeasured as 1 unit.
46Supply and fixing Distribution Boarddouble Doormade out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete, all as specified and directed. (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quoted rate)
47Supply and fixing Bus bar chamber made out of from CRCA sheet 2 mm thick including making concealed in the wall with nuts and bolts andcolor wash to match with exsting, powder coated of size 600 x450 x 150 mm in IP-65 consisting of the following :- (a)Incoming MCCB 100 Amp 4 pole 16 KA, 415 V- 01 No(b)Outgoing Alluminium Bus bar duly insualted RBY and Black- 01 Set(c)Led indicator RYB = 01 Set
48Supply and fixingin repair MCB SPN, 240 volts, 40 to 63 Amp, rupturing capacity 10 KA, ‘B’ curve type complete, all as specified and directed.
49Supply and fixingin repairMCB single pole, 240 volts, 6 to 32 Amp, rupturing capacity 10 KA, ‘B’ curve type complete, all as specified and directed.
50Supply and fixing in repairMCB, single pole, 240 volts, 40 to 63 Amp, rupturing capacity 10 KA, ‘B’ curve type complete, all as specified and directed.
51Supply and Fixing metal enclosure (plug & socket type DB) complete including single pole and neutral enclosure with two pin, earth plug and socket complete with one SP MCB, C Curve type of capacity 20 Amp, 10 KA complete, all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail