Tender For Comprehensive Maintenance Of Md/Otm Accommodation Including Joinery, Flooring, Plumbing, Plastering, Internal Electric Work And Other Misc B / R And E / M Work In Zone-A And Zone-B At Raiwala Mil Stn, raiwala-Uttarakhand

Military Engineer Services-MES has published Tender For Comprehensive Maintenance Of Md/Otm Accommodation Including Joinery, Flooring, Plumbing, Plastering, Internal Electric Work And Other Misc B / R And E / M Work In Zone-A And Zone-B At Raiwala Mil Stn. Submission Date for this Tender is 26-03-2024. Electrification Work Tenders in raiwala Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

42706452
Corrigendum : Tender For Comprehensive Maintenance Of Md/Otm Accommodation Including Joinery, Flooring, Plumbing, Plastering, Internal Electric Work And Other Misc B / R And E / M Work In Zone-A And Zone-B At Raiwala Mil Stn
Open Tender
Indian
Uttarakhand
raiwala
26-03-2024

Tender Details

Tender For Comprehensive Maintenance Of Md/Otm Accommodation Including Joinery, Flooring, Plumbing, Plastering, Internal Electric Work And Other Misc B / R And E / M Work In Zone-A And Zone-B At Raiwala Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work:COMPREHENSIVE MAINTENANCE OF MD/ OTM ACCN INCLUDING JOINERY, FLOORING, PLUMBING, PLASTERING, INTERNAL ELECTRIC WORK AND OTHER MISC B/R AND E/M WORK IN ZONE-A AND ZONE-B AT RAIWALA MIL STN
Sl. No. Item Description
1Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each.
2Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm butnot exceeding 4.0 Sq.m each.
3Refixing of shutters in same opening of any descrption after easing and adjusting ,n exc 1.50Sqm.
4Refixing of shutters in same opening of any descrption after easing and adjusting , exc 1.00Sqm but n exc 2.00 Sqm.
5Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each .
6Taking down shutters of any description n.exc 1.00 sqmeach.
7MS Fastner of size 200 to 250mm for fixing wooden door / window frame and like in postion
8S & F forFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
9S & F forFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
10S&F 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and complete all as specified and directed.
11M&L for Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified and directed. Note- S S Butt hing measured and paid separately at relevant item
12Providing and fixing factory made 30 mm thick 100% solid WPC window glazed shutter / wire mesh shutter 95 mm x35mm thick. Made from WPC material with density not less than 800 kg/cum. All four corner are fusion welded & screwed with 8 x 50mm self-screws for additional strength. After joining all 4 corner clear space to be paneled with 5mm thick glass / S S mosquito mesh after glazing of inside of shutter 10 x 12mm pvc “L” shape bead to be nailed or sticked with shutter. Provided 2 Nos SS hinges of 100 mm, 1 Nos aluminium handle of 100 mm ,2 Nos aluminium tower bolt of 100mm and 01 peg stay for each shutter (Glazed and Gauzed) incl factory made 100 % solid WPC window frame 125 mm x 65 mm double rebated frame & mullion 125 x 80mm. made from WPC (Single extruded process) material comparising of virgin PVC polymer of K value 57-60 (suspension grade), calcium carbonate and natural fibers (Wood powder/ rice husk/wheat husk) and nontoxic additives fabricated with meter joints after applying PVC solvent cement & screwed with fully body treated star headed screws having minimum frame desity not less than 800 kg / cum, having good screw holding capacity (screw withdrawal strength of (min 990N). Minimum compressive strength of 58 N/mm2. Modulus of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / mosquito proof & fire retardant & fixed in position with S S dash fasteners / hold fast of required dia and length. Window shall be provided with MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat including painting with countersunk holes at both vertical ends. Gap between the bars should not be more than 125mm. All as per specification drawing as directed by Engr-in-charge Note - (i) Glazed and Gauzed shutter both are deemed in this quoted rate (ii) Glass pane, wire mesh and grill are deemed in this quoted rate
13S & Fstainless steel barrel tower bolt of200 mm lengthofextruded section (ISI Marked). Complete all as specified and directed
14S & Fstainless steel barrel tower bolt of300 mm lengthofextruded section (ISI Marked). Complete all as specified and directed
15S & Fin repairs stainless steel barrel tower bolt of300 mm lengthofextruded section (ISI Marked). Complete all as specified and directed
16S&Fstainless steel handles,fabricated type, anodised 200 mm long,(ISI Marked)all as specified and directed.
17S&Fstainless steel handles,fabricated type, anodzed 125 mm long,(ISI Marked)all as specified and directed.
18S&F in repair stainless steel handles,fabricated type, anodised 200 mm long,(ISI Marked)all as specified and directed.
19S&Fstainlees steel sliding door bolt of 300mm long, with hasp, staple (bolt type) complete all as specified and directed.
20S & F in repairs stainlees steel sliding door bolt of 300mm long, with hasp, staple (bolt type) complete all as specified and directed
21S&F Stainlessnon megnetic steel butt hinges of size 100mm.(ISI Marked). Complete all as specified and directed .
22S&FFloor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm. complete all as specified and directed.
23S&F 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller platecomplete all as specified and directed.
24S&F in repair 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete. all as specified and directed.
25S&Fin repairs Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
26M & L in repairs Plain fillets of second class hard wood (suitable for joiner’s and carpenter’s work, locally available) section area exceeding 3 Sq.cm and not exceeding 6 Sq.cm, square, rectangular or triangular in section, clean sawn secured with nails. complete all as specified and directed.
27M & L in repairs fstainless steel non magnetic curtain rod 20mm dia with fixing brackets and decorative type knobs both side of each rod, complete all as specified.. Note:: Measurement will be taken between end point of knobs.
28S&F in repairs of aluminiumdoor seal upto 1200 mm long onbottom of door complete all as specified and directed.
29Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads or from metal frames including punching or drilling out old glazing pins /spring clips and providing and fixing new one. complete all as specified and directed.
30S&FGlazing with plain sheet glass, ordinary quality, 5.5 mm thick and glazing with oil puttyor aluminium or PVC beading insquares n. exceeding 0.5 Sq.m in each pane. complete all as specified and directed.
31S&FGlazing with plain sheet glass, ordinary quality, 4 mm thick and glazing with oil puttyor aluminium or PVC beading insquares notexceeding 0.5 Sq.m in each pane. complete all as specified and directed.
32S&F in repairs S S peg set, 150 mm complete all as specified and directed.
33S & F in repairsAluminium body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 oto 1000 mm in width and of weight between 61 to 80 Kg. complete all as specified and directed.
34Dismantlingfloor hearth or wall tiling including cement mortar bedding (but not backing), removingand rubbish off the premises from MoD all as specified and directed.
35M&L for Non- skid coloured ceramictiles of any design and pattern, 300X300X7 to 8 mm thick, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE .Complete all as specified and directed
36M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mmthick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) .Complete all as specified and directed
37Dismantling of cast iron or reinforced concrete drain pipes up to 110mm dia , jointed in cement mortar and taking out of trenches if required .complete all as specified and directed.
38S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors.complete all as specified and directed.
39S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors.complete all as specified and directed.
40S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.complete all as specified and directed.
41S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.complete all as specified and directed.
42S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
43S & F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
44S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
45S & F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
46S & F PVC (SWR) reducers of size 110 mm x75 mmcomplete all as specified and directed.
47S & F 75 mm bore PVC (SWR) junction single (Single `T") equal or unequal with access door.complete all as specified and directed.
48S & F 110 mm bore PVC (SWR) junction single (Single `T") equal or unequal with access door.complete all as specified and directed.
49S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed.
50S & F 75 mm bore PVC (SWR) Multi floor trap including jointing with solvent cement complete all as specified and directed.
51S & F 110 mm bore PVC (SWR) P Trap complete all as specified and directed.
52S & F 75 mm bore PVC (SWR) floor Trap, plain with grating inclding jointing with solvent cement .complete all as specified and directed.
53S&F stackclampsmade out of 40mmx 3 mm flat iron includingbolts and nuts and securing ends of stays to walls or roof with fastner for 100/110 mm diapipe complete all as specified and directed.
54Demolition of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelvesetc.Complete all as specified and directed
55M & L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed.
56Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
57M&L for Brick work with sub-class `B" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar (1:6) complete all as specified and directed.
58All as per item No 57 here-in-before but except bricks.
59S&Fin repair new rotational moulded polyethylene water storage tank 1000 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position includingS&F 20 mm diaballvalves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
60S&F in repairs new rotational moulded polyethylene water storage tank 500 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position includingS&F 20 mm diaballvalves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
61Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .bore complete all as specified and as directed.
62Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia borecomplete all as specified and as directed. .
63M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed
64Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed
65M&L for cutting chases on brick or concrete surface for concealed water tubing or / similar work ofgirth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed.
66M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work ,medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed
67S&F in repairs bib taps 15mm bore of standard PTMT any colour ahigh pressure screwed for iron pipe and fixed in repair (Minimum weight 15mm-90gms/20mm- 125gms).complete all as specified and as directed.
68S&F in repairs pillar taps 15mm bore of standard PTMT any colour ahigh pressure screwed for iron pipe and fixed in repair (Minimum weight 15mm-90gms/20mm- 125gms).complete all as specified and as directed.
69S&Fin repairs Sinks with drainage board made of stainless steel 0.8mm thick kitchen or laboratory with plugs, washers; including bedding in cementmortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460and bowl size 410mm x 330 mm x 160mm.complete all as specified and as directed.
70S&Fin repairs Sinks with out drainage board made of stainless steel 0.8mm thick kitchen or laboratory with plugs, washers; including bedding in cementmortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 495 mm x 420and bowl size 410mm x 330 mm x 160mm.complete all as specified and as directed.
71S&F in repairStainless steel kitchen plate rack 0.80mm thick sheet of over all size 31" x 30" x 10" fixed with steel screws and steel rawal plugs complete all as specified and as directed.
72S&F in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cupscrewed down high pressure with crutch or butterfly handleor concealed screwed both ends for iron pipe or for unions.complete all as specified and as directed.
73S&F in repairs Stop anglevalves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe completeall as specified and as directed. .
74S&F in repairs 15 mm bore chromium plated bib taps long body, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
75S&F in repairs 15mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts, screwed for iron pipecomplete all as specified and as directed.
76S&F in repairs towel Rail 600 mm long fixedwith and including Chromimum plated brass screws and wooden plastic cleats (Min weight 190 gms)complete all as specified and as directed.
77S&F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing tosteel pipe or union complete all as specified and as directed.
78S&F , in repair, Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.complete all as specified and as directed.
79S&F in repair to glass corner shelfof size 300mm fixed with chromium plated brass brackets complete all as specified and directed.
80S&F in repair for PVC Connections 15mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
81S&F in repairWash basins (Padestal pattern) 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting complete all as specified and as directed.
82S&F in repairWash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting complete all as specified and as directed.
83S&F in repairs for Grating ,round 127 mm diachromoum plated complete all as specified and as directed.
84S&F in repair to 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
85S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), lowlevel , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make.complete all as specified and directed
86S&F in repairs Vitreous china Squatting pan , "Orissa pattern, size 580x440 mm white, with integral foot restexcluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor . complete all as specified and as directed.
87S&F in repairVitreous China Half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement,complete all as specified and as directed.
88S&FBrass CP urinal spreader fixing with 15 mm dia pipe.complete all as specified and as directed.
89S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints completeall as specified and as directed.
90S&F in repair StainlessSteel Jet spray with 1.5 mtr braided tube complete all as specified.
91S&F in repair 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered "Hot" or "Cold" ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe complete all as specified.
92S&F in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm borepipes complete all as specified.
93S&Fin repairs towel rack fixed with and including CP brass screws and wooden / plastic cleats,complete all as specified.
94S&F in repairs Health Faucet with hose & hook (complete set) fixed to angle / stop cock 15 mm dia all as specified
95S&Fin repairstoilet paper holder chromium plated fixed to wall with chromium plated (CP) brass screws complete all as specified.
96S&F in repair to chromium plated towel ring complete all as specified
97S&F repair 32 mm dia lowdensity polyethylene pipe (LDPE) of pressure rating @ 6Kg f per Cm Cm Square fixed to walls, ceilings or in floors etc.complete all as specified.
98S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) incl close seat cover, hinges,fixing accessories and accessories set and cistern with cistern fitting complete, flush pipe incl all joints MakeJaquar Essco Cat part no ECS-WHT-851S220NPP or equivalentmake complete all as specified..
99Taking down cement plaster on brick , concrete or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed.
100M&L for 15mm thick plastering on fair faces of brick wall in CM (1:6) surface finished even and fair complete all as specified and directed.
101M&L preparation of newly plastered surfaces of wall andapplying two coats ofdistemper oil emulsion white or tinted over and incl of one coat of alkali resistance priming paint and 1mm thick wall care putty on wall surface.complete all as specified and directed
102E/M PORTIONMaterial & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealedPVC conduit,medium grade(ISImarked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade(Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including whitecover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ii)If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
103All as per above item No.102 above but One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
104All as per above item No 102above but for One 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size,complete all as specified and directed .
105All as per above item No.102 above but controlled by two, two wayswitch5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed .
106All as per above item No.102abovebut with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point with contineous earth wire of 2.5 Sqmm complete all as specified and directed .
107All as per above item No.102 above but for existing concealed conduit inside wall, ceilingetc(light, fan, call bell) complete all as specified and directed .
108All as per above item No.102 above but for existing concealed conduit inside wall, ceilingetcbut for One 3pin/5pin 5/6 Amps socket out let on same board with other switches, with cables 1.5 sq mm size,complete all as specified and directed .
109All as per above item No.102 above but for existing concealed conduit inside wall, ceilingetcbut forOne 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size,complete all as specified and directed .
110All as per above item No.102 above but for existing concealed conduit inside wall, ceilingetc but controlled by two, two wayswitch5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed .
111All as per Item No 102 abovebut for existing concealed conduit inside wall, ceilingetc with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point with contineous earth wire of 2.5 Sqmm complete all as specified and directed .
112S&F switch Modular single pole,one way 6 Amps , 1 module,230 volts, 50 hzall as specified and directed
113S&F switch modular , one-way 16Amps,1 module 240 Volts ACall as specified and directed.
114S&FModular Socket outlet, 6A - 3 pin, 2 module ISI marked, 230 volts, 50 hz all as specified and directed.
115S&F modular socket, 6A/16A -2/3 pin combined 2 module230 volts, 50 hz all as specified and directed .
116S&F switch modular typesingle pole, two way 6 Amp, 1 moduleISI marked, 230 volts, 50 hz all as specified.
117S&F bell push modulartype single pole one way 6 Amps, 1 module with with indicator, ISI marked all as specified.
118S&F step socket type modular fan regulator 120/280 V 2 module with indicator all as specified.
119S&F bell ding dong AC 230/240 volts single pole , all as specified.
120S&F ceiling rose surface bakelite 65/25 mm dia having three terminals all as specified
121S&F in repair Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings all as specified and directed.
122S&F in repairs /replacement switch piano 230 volts, AC, flush typesingle pole, one way 5/6 Amps ISI marked all as specified.
123S&Fin repair/replacement switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one wayall as specified.
124S&F in repairs/replacement, socket out let3/5 pin 5/6 Ampsflush type all as specified. .
125S&F in repair socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC all as specified and directed
126S&F in repair batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
127S&F in repair bell ding dong AC 230 volts single pole all as specified.
128S&F in repair step socket type fan regulator 120/280 V , ISI marked all as specified.
129S&F sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC, 8 way with 200 Amps rated bus bar all as specified and directed.
130S&F sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC, 4 way with 200 Amps rated bus bar. all as specified.
131S&F sheet metal enclosure double door type for MCBs DB TPN 415V AC, 4 way with 200 Amps rated bus bar. all as specified.
132S&F sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar all as specified.
133S&F MCBSPN 32 Amp 240 V AC 10 KA "C" Curve repturingcapacity all as specified.
134S&F MCB SP 6 to 32 Amp "B" series 10 KA repturingcapacity complete all as specified.
135S&FMCB TPN/ FP 16-32 Amp, 415 V AC "C" series 10 KA repturingcapacity complete all as specified.
136S&F single pole and neutral enclosure modular type with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA repturingcapacity 240 Volts AC all as specified.
137S&F sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected withmain earth dolly including cuttingchasesand making good disturbed portionall as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
138S&F sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit or more medium grade surface/ concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected withmain earth dolly including cutting chasing and making good disturbed portionall as specified and as directed .Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
139M&L for repair and replacement of existing rusted metal circuit box including hylam sheet and switch, sockets, regulators with new 1/ 2 way-6way modular type metal box with and incl decorative polycarbonate frame for housing modular switches, sockets, fan regulatrs etc including white cover plate complete and connect existing circuit wiring with new switches &testing complete all as specified and directed.Note:- 1 payment will be done for each module as per rates quoted by the contractor 2.switch /sockets /regulators will be paid seperately.
140Dismantling and taking down U/Spoint wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box excluding conduit when in wiring in existing conduit, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
141Dismantling and taking downu/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc excluding conduit when in wiring in existing conduit complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
142Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc.complete all as directed