Tender For Construction Of Pds Building At Vinayagam Nager In Madharapakkam Panchayat
Tender Value
12.70 Lakhs
Estimated cost
Bid Submission
11 Mar 2024
0 days left
EMD
26000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
gummidipoondi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Pds Building At Vinayagam Nager In Madharapakkam Panchayat
BOQ
| Sl. No. | Item Description |
| 1 | Construction of PDS in Vinayagam nagarin MadharapakkamPanchayat |
| 2 | EARTHWORK EXCAVATION for foundation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting but inclusive of shoring, strutting and baling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15cm thick, well rammed and consolidated and depositing the surplus earth within the compound in places shown by the departmental officers with initial lead and lift etc.,including levelling the sites complete complying with standard specifications and as directed. |
| 3 | Collection and supply of sandand filling in to the basement including cost and conveyanceto the siteand all labour charges for filling as per standard specifications |
| 4 | Cement concrete 1:4:8 mix using 40mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing,laying and curing etc complete |
| 5 | RCement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and providing fixtures like fan clamps in the RCC floor or roof slabs wherever necessary and bearing surfaces of walls , sides and bottom of the slabs, beams etc.,as directed by the departmental officers complete complying with standard specifications. |
| 6 | RCement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and providing fixtures like fan clamps in the RCC floor or roof slabs wherever necessary and bearing surfaces of walls , sides and bottom of the slabs, beams etc.,as directed by the departmental officers complete complying with standard specifications. |
| 7 | Brick work in CM 1:5 mix using country bricks ground moulded of size 83/4\"x41/4\"x21/4\" for the following including curing etc., complete complying with standard specifications. Rate for 10m3 Basement |
| 8 | Brick work in CM 1:5 mix using country bricks ground moulded of size 83/4\"x41/4\"x21/4\" for the following including curing etc., complete complying with standard specifications. Rate for 10m3Walls Above Basement (Super Structure) |
| 9 | Supplying and fabrication of steel including cost and conveyance of bending to shape and tying in position and forming grills for all R.C.C works including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing |
| 10 | Supplying and erecting centeringshuttering includingnecessary supportsforplane etc., complete. |
| 11 | Supplying and erecting centeringshuttering includingnecessary supportsforplane etc., complete. |
| 12 | Floor finish with granolithic flooring in CC 1:2:4 mix using 10 to 12mm chipsfor 40mm thick including cost and conveyance of all materials and labours etc., complete |
| 13 | Paving the floor with scratch proof ceramic tiles of any colour and any size laid in CM 1:2, 20mm thick. And pointing with white cement 0.4 Kg per Sqm mixed with colouring pigment to suit the colour of the tiles including finishing the joints neatly complying with the standard specifications and as directed by the departmental officers. (The ceramic tiles should be got approved from the Departmental officers before execution). |
| 14 | Dadooing walls with Glazed tiles of any colour and any size laid in CM 1:2, 10mm thick. and pointing with white cement 0.4 Kg per sqm mixed with colouring pigment to siut the colour of the tiles including finishing the joints neatly complying with the standard specifications and as directed by the departmental officers. The Glazed tiles should be got approved from the Departmental officers before execution. |
| 15 | Plastering with cement mortar 1:5 mixto12mmthick including cost and conveyance of all materials to site and all labour charges etc |
| 16 | Plastering with cement mortar 1:3 mixto 10 mm thick including cost and conveyance of all materials to site and all labour charges etc complete |
| 17 | Plastering with cement mortar 1:3 mixto 20 mm thick including cost and conveyance of all materials to site and all labour charges etc complete |
| 18 | Finishing the top of roof with one course of PRESSED TILES of size 20 cm X 20 cm X 2 cm laid in cement mortar 1:3 (One cement and three Sand) 12mm thick mixed with water proofing compound conforming to I.S. at 2% by weight. |
| 19 | Distembering two coats with best approved distemberincluding cost and conveyance of all materials to site and all labour charges etc complete |
| 20 | Distembering two coats with best approved distemberincluding cost and conveyance of all materials to site and all labour charges etc complete |
| 21 | Exterior Emulsion painting two coats with best approved quality and colourpaint over one coat of Base coat including cost and convyance of all materials to work site and labour charges etc., complete. |
| 22 | Supplyingof steel doors, windows, ventilators etc., withbest approved best qualityetc., complete complying with standard specifications and as directed by the departmental officers. |
| 23 | Doors D |
| 24 | Doors D1 |
| 25 | Window W(1.00x1.30)m |
| 26 | Ventilator V (0.90 x 0.60m) |
| 27 | Rolling shutter 1 |
| 28 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete |
| 29 | Labour Charges for Fixing the Doors inculding all Charges etc.. |
| 30 | Labour Charges for Fixing theSteel Window inculding all Charges etc.. |
| 31 | Supplying & fixingwith cuddapah slabs 20-30mm thick for cup board including all cost and conveyance and all labour charges etc .comp. |
| 32 | Cost and supply of Oriya type Indian baby friendly water closetwith \"P\" or \"S\" trap etc., complete. ( White ) |
| 33 | Supply and fixixng of 15mm dia Brass CP screw down tap |
| 34 | Supply and fixixng of 1000 litre HDPEtank |
| 35 | Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wallwith3 mm thick Hylum sheet cover withTW boxAnd 5 A FT switch with continuous earth connection of 14 SWG TC wire for making good ofthe concealed portion with suitable colour for PVC Open Light point / fan point (For electronic Regulator) SD 18 |
| 36 | Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutorof 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wallwith150 mm X 100 mm X 113 mm TW switch boxwith3 mm thick Hylum sheet cover for 5 A 3 pin non interlocking CS plugwith continuous earth wire connection of 14 SWG TC wire for making good ofthe concealed portion with suitable colour forconcealed PVCplugpointSD 36 |
| 37 | Supply and run of 2 of 1.50 sq.mm (22/0.30) PVC insulated SC unsheathed copper Conductor of1100 V grade on 7/20GI bearer wire for service connection mains SD 65 |
| 38 | Supply and run of 2 X 1.5 sq.mm(22 / 0.30) PVC insulated SC unsheathed copper Conductor of1100 V grade in 25 mm dia GI pipe( Class \" B \" ) suitably bent at both ends with necessary angle iron upright and end supports for mains. SD 70 |
| 39 | Supply and fixing of WT bulk head fitting with guard ( Philips / Bajaj / Crompton / K Lite ) suitable for incandescent lamp with 60 W bulb.SD 84 |
| 40 | Supply and fixing of CFL bulb SD 80 |
| 41 | Supply and fixing of 1200 mm ( 48\") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mmdown rod on the existing clamp. SD 110 |
| 42 | Supply and fixing of 16 Amps DPIC Switch of 500 V with fuse and neutral (Side Handle) on suitable TW box PWD EarthingSD 142 |
| 43 | Supply and fixing of TNEB Meter boardSD 125 |
| 44 | Provision for E B Deposit charges etc., |
| 45 | Provision for Stoneware pipes and specials |
| 46 | Provision for PVC pipes and specials |
| 47 | GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column \"BB\" for all works in this package}(Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD) |
AI Tender Summary
Tender Timeline
Mar 05, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedMar 11, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 11, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender