Improvement Of Lighting / Electrification System At Jeetgarh Ugr, Delhi-Delhi

Delhi Jal Board-DJB has published Improvement Of Lighting / Electrification System At Jeetgarh Ugr. Submission Date for this Tender is 11-03-2024. Electrification Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42681896
Improvement Of Lighting / Electrification System At Jeetgarh Ugr
Open Tender
Indian
Delhi
Delhi
11-03-2024

Tender Details

Improvement Of Lighting / Electrification System At Jeetgarh Ugr- 1 New Generation Energy Saving And Environmental Friendly Long Life Led Street Light Made Up Of Pressure Die Cast Aluminum Housing With High Efficient Led As Lighting Source And Pc Cover Having Top Opening Separate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik07. 90 Watt 2 Installation Of Led Light 90 Watts On Street Light Pole After Erection With All Safety Measures With The Help Of Skilled Labour / Technician As Required. 3 Demolishing Hard Rock / Brick Work With The Help Of Hydralic Machine And Heavy Labour Including Stacking Of Serviceable Material And Disposal Of Unserviceable Materiallead As Per Direction Of Engineer-In-Charge. 4 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) ( Dsr 2022 Code 7.7.1 ) 5 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1.Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. Upto 35 Sq. Mm. ( Dsr 2022 Code 7.1.1 ) 6 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) ( Dsr 2022 Code 21.1.20 ) 7 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required 3 X 2.5 Sqmm ( Dsr 2022 Code 1.17.12 ) 8 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required 3 X 4 Sqmm ( Dsr 2022 Code 1.17.21 ) 9 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Singlecore Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 10 + 1 X 6 Sqmm ( Dsr 2022 Code 1.14.5 ) 10 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B ( Dsr 2022 Code 1.10.2 ) 11 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 Amps Switch ( Dsr 2022 Code 1.24.1 ) 12 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5 / 6 Amp Socket Outlet ( Dsr 2022 Code 1.24.4 ) 13 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 / 16 Amps Switch ( Dsr 2022 Code 1.24.3 ) 14 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 Amp Socket Outlet ( Dsr 2022 Code 1.24.5 ) 15 Supplying And Fixing The Following Size / Modules G.I Box Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Reqd. 6 Module ( Dsr 2022 Code 1.27.4 ) 16 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 12 Way Double Door ( Dsr 2022 Code 2.3.3 ) 17 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole ( Dsr 2022 Code 2.10.1 ) 18 Supplying And Fixing Following 63 Amp, Double Pole, 240 Volts, Dp Mcb In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( Dsr 2022 Code 2.12.2 19 Supplying And Fixingstepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 20 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit / Batten Along With All Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25 Mm ( Dsr 2022 Code 1.21.2 ) 21 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit / Batten Along With All Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm ( Dsr 2022 Code 1.21.1 ) 22 Providing And Fixing Of 48 ( 1200 Mm ) Ceiling Fan With All Accessories And Making Connection Etc As Reqd. At Site ( Havells / Cg / Orient / Usha / Almonard / Djb Approved ) ( Sor 2022 Code 20.1.1 ) 23 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Alumium Conductor Cable Of 1.1 Kv Grade As Required 4 X 16 Sq. Mm ( Dsr 2022 Code 9.1.33 ) 24 Supply Of Xlpe Insulated, Pvc Sheathed Al.Conductor Armoured Cable For Working Voltage Upto 1.1 Kv Conforming To Is 7098 / 1988 Of Following Sizes 4C X 16 Sq Mm Make: Gloster / Grandlay / Universal / Havells / Polycab / Djb Approved. 25 Supply Of Xlpe Insulated, Pvc Sheathed Al.Conductor Armoured Cable For Working Voltage Upto 1.1 Kv Conforming To Is 7098 / 1988 Of Following Sizes 4C X 25 Sq Mm Make: Gloster / Grandlay / Universal / Havells / Polycab / Djb Approved. 26 Erection Of G.I Pole Of Following Length In Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Foundation Including Excavation And Refilling Etc. As Required. Above 8.0 Metre And Upto 10.0 Metre 27 Painting Of Street Light Poles With Primer And 2 Coats Of High Gloss Enamel Paint. Make:- Asian / Berger / Nerolac. 28 Supplying And Fixing Of 32 Mm Dia X 1.80 Metres Long G.I. Pipe ( Medium Class ) Bracket For Mounting Of Fluorescent / Hpmv / Hpsv Street Light Fitting On Pole Including Bending The Pipe To Therequired Shape, . This Also Include Supply & Fixing Of 1 Nos, 32 Mm Dia X 1.80 Metres Long G.I. Pipe With Bend For Junction Box. 29 Making Provision Of Supply Of 65 Mm Dia G.Istreet Light Pole , 4.5 Mtr Long Approx Heavy Duty Complete Withand 65 / 32 Reducerand 1 X 1 G.I Base Plateetc. As Reqd.At Site 30 S / I / T / C Of 100 Watt Flood Light Fitting Pressured Dia Cast Housing With Ip66 Protection Efficient High 220-240V Output Emitter Led For Better Distribution With Dimension 447 X 163 X 327 Mmand 6500 Colour With Lumens 15500 With All Accessoires Etc As Etc As Reqd. At Site. ( Havells ) 31 Supplying And Fixing Of Angle Frame Of Suitable Size ( 50 X 50 ) Including Excavation And Repairing The Same Etc As Reqd. At Site. 32 Supplying, Installation, Testing And Commissioning Of Astronomical Time Switch Of Following Configuration To Be Mounted In Feeder Pillars / Lighting Dbs For Automatic Switching On& Off Of Street Lights At Sun Set & Sun Rise Or Twilight ( Auto On, Auto Off, Auto Modes ) With Manual Override Facility With 12 / 24 Hour Display Format With Suitable Battery And Indication For Relay Status I / C Programming At Site Complete As Required. 3 Output ( 1Output Per Phase ) And Suitable For Three Phase Supply Power Supply Connections By Fixing The 100 Amp Mccb– 1 No., 63 Amp Dp Mcb-6 No. , 3 No’S Indicating Led Fittings With 6 Amp Sp Mcbs Etc As Required 33 Supply Of Smc Junction Boxes Anti-Corrosive Water Resistant, Uv Protected, High Temp Resistant, Weatherable And Suitable For All Kinds Of Climatic Conditions. Self-Colour Fire Retardant And High Dielectricstrength Maintenance Free. Make: Bajaj / Hensel / Syntex / Other Djb Approved Make 34 Installation Of Junction Boxes On The Each Pole With The Help Of Clamps, Nut & Bolts Etc. 35 S / F Of 20 Watt Led 4 Feet Fitting Complete With All Accessories I / C Making Connection Etc As Reqd. ( Cg / Havells / Bajaj / Philips / Djb Approved ) 36 Installation, Testing And Commissioning Of Led Fitting Of All Type Complete With All Accessories Directly On Ceiling Wall Including Connection With 1.5 Sqmm Frls Pvc Insulated Copper Conductor Cable And Earthing Etc As Reqd. At Site ( Dsr 2022 Code 1.41 ) 37 Supplyingand Laying Of Hdpe Flexible Pvc Pipe Complete With All Accessories I / C Jointing And Making Good The Same Etc As Reqd. At Site 38 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required For 1 Runs. ( Dsr 2022 Code 5.16 ) 39 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. As Required, ( Dsr 2022 Code 5.2 ) 40 Providing And Laying Earth Connection Frlsom Earth Electrode With 6 Swg Dia G.I Wire In 15 Mm G.I Pipe Frlsom Earth Electrode Including Connection With G.I Thimble Excavationand Refilling As Reqd. ( Dsr 2022 Code 5.12 ) 41 Loading, Unloading, Cartage And Transportation Charges For The Abovepole Upto The Side I / C Charges Of Heavy Labour Etc. As Per Site Requirement. 42 Testing And Commission Of Complete Work In The Presence Of Engineer-In-Charge With Full Satisfaction.

Key Value

Document Fees
INR 500 /-
EMD
INR 43800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Improvement of lighting/electrification system at Jeetgarh UGR
Sl. No. Item Description
1New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. 90 watt
2Installation of LED light 90 Watts on street light Pole after erection with all safety measures with the help of skilled labour/technician as required.
3Demolishing hard rock/ brick work with the help of Hydralic machine and heavy labour including stacking of serviceable material and disposal of unserviceable materiallead as per direction of Engineer-in-charge.
4Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) ( DSR 2022 code 7.7.1 )
5Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1.KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm.( DSR 2022 code 7.1.1 )
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) ( DSR 2022 code 21.1.20 )
7Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 2.5 sqmm( DSR 2022 code 1.17.12 )
8Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 4 sqmm( DSR 2022 code 1.17.21 )
9Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. 2 x 10 + 1 x 6 sqmm( DSR 2022 code 1.14.5 )
10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B ( DSR 2022 code 1.10.2 )
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch ( DSR 2022 code 1.24.1)
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet ( DSR 2022 code 1.24.4 )
13Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amps switch ( DSR 2022 code 1.24.3 )
14Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet ( DSR 2022 code 1.24.5 )
15Supplying and fixing the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd. 6 module ( DSR 2022 code 1.27.4 )
16Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door ( DSR 2022 code 2.3.3 )
17Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole ( DSR 2022 code 2.10.1 )
18Supplying and fixing following 63 amp, double pole, 240 volts, DP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( DSR 2022 code 2.12.2
19Supplying and fixingstepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
20Supplying and fixing of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm ( DSR 2022 code 1.21.2)
21Supplying and fixing of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm ( DSR 2022 code 1.21.1)
22Providing and fixing of 48" ( 1200 mm ) ceiling fan with all accessories and making connection etc as reqd. at site ( Havells/ CG / Orient/ Usha/Almonard/DJB approved )( SOR 2022 code 20.1.1)
23Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE alumium conductor cable of 1.1 KV grade as required 4 x 16 sq. mm ( DSR 2022 code 9.1.33)
24Supply of XLPE insulated, PVC sheathed Al.conductor Armoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 4C x 16 SQ mm Make: Gloster/Grandlay/UNIVERSAL/HAVELLS/ Polycab/DJB approved.
25Supply of XLPE insulated, PVC sheathed Al.conductor Armoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 4C x 25 SQ mm Make: Gloster/Grandlay/UNIVERSAL/HAVELLS/ Polycab/DJB approved.
26Erection of G.I pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre
27Painting of street light poles with Primer and 2 Coats of High gloss Enamel Paint. Make:- Asian/Berger/Nerolac.
28Supplying and fixing of 32 mm dia X 1.80 metres long G.I. pipe(medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to therequired shape,. This also include supply & fixing of 1 Nos,32 mm dia X 1.80 metres long G.I. pipe with bend for junction box.
29Making provision of supply of 65 mm dia " G.Istreet light pole , 4.5 mtr long approx heavy duty complete withand 65/32 reducerand 1" x 1" G.I base plateetc. as reqd.at site
30S/I/T/C of 100 watt flood light fitting pressured dia cast housing with IP66 protection efficient high 220-240V output emitter LED for better distribution with dimension 447 X 163 x 327 mmand 6500 colour with lumens 15500 with all accessoires etc as etc as reqd. at site. ( Havells )
31Supplying and fixing of angle frame of suitable size ( 50" x 50" ) including excavation and repairing the same etc as reqd. at site.
32Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On& OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1output per phase) and suitable for three phase supply power supply connections by fixing the 100 amp MCCB– 1 No., 63 Amp DP MCB-6 No. , 3 No’s indicating LED fittings with 6 amp SP MCBs etc as required
33Supply of SMC junction boxes anti-corrosive water resistant, UV protected, High temp resistant, weatherable and suitable for all kinds of climatic conditions. Self-colour fire retardant and high dielectricstrength maintenance free. Make: Bajaj / Hensel / Syntex/Other DJB approved make
34Installation of junction boxes on the each pole with the help of clamps, nut & bolts etc.
35S/F of 20 watt LED 4 feet fitting complete with all accessories i/c making connection etc as reqd. ( CG/Havells/Bajaj/Philips/DJB approved)
36Installation, testing and commissioning of LED fitting of all type complete with all accessories directly on ceiling wall including connection with 1.5 sqmm FRLS PVC insulated copper conductor cable and earthing etc as reqd. at site ( DSR 2022 code 1.41)
37Supplyingand laying of HDPE flexible PVC pipe complete with all accessories i/c jointing and making good the same etc as reqd. at site
38Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required for 1 runs.( DSR 2022 code 5.16)
39Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. as required,( DSR 2022 code 5.2)
40Providing and laying earth connection FRLSom earth electrode with 6 SWG dia G.I wire in 15 mm G.I Pipe FRLsom earth electrode including connection with G.I thimble excavationand refilling as reqd.( DSR 2022 code 5.12)
41Loading, unloading, cartage and transportation charges for the abovepole upto the side i/c charges of heavy labour etc. as per site requirement.
42Testing and commission of complete work in the presence of Engineer-in-charge with full satisfaction.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail