}

Tender For Construction Of Various Project At Rakauli In Mau, Varanasi-Uttar Pradesh

Uttar Pradesh Housing And Development Board-UPAVP has published Tender For Construction Of Various Project At Rakauli In Mau. Submission Date for this Tender is 07-03-2024. Kitchen Equipment Tenders in Varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42660064
Tender For Construction Of Various Project At Rakauli In Mau
Open Tender
Indian
Uttar Pradesh
Varanasi
07-03-2024

Tender Details

Tender For Construction Of Various Project At Rakauli In Mau- 1 Multipurpose Hall ( Civil Work ) ( Rakauli ) 2 Excavation Infoundation Inordinary Soil ( Loam Clay Or Sand ) Including Lift Upto 1.5M Lead Upto 30.0 M& Including Filling Wateringand Rammingof Excavated Earth Into The Space Between The Building & Sides Offoundation Trenches Or Into The Plinth And Removal& Disposal Surplus Earthas Directed By The Engineer I / C Within A Lead Of 30 M.From Foundation Trenches.0.30 M & Above 3 Excavation Infoundation Inordinary Soil ( Loam Clay Or Sand ) Including Lift Upto 1.5M Lead Upto 30.0 M& Including Filling Wateringand Rammingof Excavated Earth Into The Space Between The Building & Sides Offoundation Trenches Or Into The Plinth And Removal& Disposal Surplus Earthas Directed By The Engineer I / C Within A Lead Of 30 M.From Foundation Trenches.Add For Additional 1.5 M Lift Or Part Of 1.5 M Lift ( 5 Km Kachha ) ( 251+254 ) 4 Filling Of Carted Earth Under Plinth And Foundation 5 Coarse Sand Filling In Plinth Including Supply Of Necessary Quantity Of Sand From A Distance Not Exceeding 8 Kms. From The Site Of Work And Including Watering, Dressing Etc Rate To Include Cost Of All Materials Labour T & P Etc Required For Proper Completion Of Work. 6 Providing And Laying Cement Concrete 1:4:8 ( 1Cement :4 Coarse Sand :8Graded Stone Ballast 40 Mm. Nominal Size ) Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work And Curing Complete, Also Including Cost Of Formwork In Foundation. 7 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Level :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Foundation ( M-20 ) 8 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Level : 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Plinth Beam ( M-20 ) 9 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Column ( M-20 ) Upto Plinth Level 10 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Column ( M-20 ) Above Plinth Level Upto Fifth Floor Level 11 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Lintel ( M-20 ) 12 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Slab ( M-20 ) 13 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Beam ( M-20 ) 14 Class-150 Brick Work In 1:6 Cementand Coarse Sandmortar In Foundation And Plinth Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work. 15 Class-150 Brick Work In 1:6 Cementand Coarse Sandmortar In Superstructure Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work 16 Class-150 Brick Work In 1:4 Cementand Coarse Sandmortar In Superstructure Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work 17 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 18 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Apiece Of Cloth Lightly Soaked In Kerosene Oil. 19 Providing And Injecting Chemical Emulsion For Preconstructional Antitermite Treatment And Creating A Chemical Barrier Under And Alround The Coloumn Pitswall Tench Basement Excavation Top Surface If Plinth Filling Junction Of Wall And Floor Along The External Perimer Of Binding Expansion Joints, Surrounding Of Pipes And Conduits Etc.Complete ( Plinth Area Of The Building At Ground Floor Only Shall Be Measuredas Per I.S.6313 ( Part Ll 1981 ) Aldrine Emulsifiable Concrete Or Any Other Approved Material Such As Hepthachlor Or Chlordance Will Be Used.The Rate Of Application Of Chemical Emulsion Shall Be As Follows:- ( 1 ) Treatment For Masonary & Foundation 5 Litres Per Sq.M. ( 2 ) Back Fill In Immediate Contract With Foundation 7.5 Litre Per Sq.M ( 3 ) Treatment Of Top Surface Of Plinth Filling 5 Liters Per Sq.M. ( 4 ) Treatment Of Soil Along External Parameter Of Building 7.50 Lire Per Sqm. ( For Payment Plinth Area To Be Measured As Per Is Code ) . 20 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 21 Providing And Fixing Double Glazed Hermetically Sealed Glazing In Aluminium Windows, Ventilators And Partition Etc. With 6 Mm Thick Clear Float Glass Both Side, Having 12 Mm Air Gap, Including Providing Epdm Gasket, Perforated Aluminium Spacers, Desiccants, Sealant ( Both Primary And Secondary Sealant ) Etc. As Per Specifications, Drawings And Direction Of Engineer-In-Charge Complete 22 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc. ) . 23 Providing And Laying Brick Coba 120 Mm Thick Laid With M-150 Class Brick Bat Coba 7.50 Cm Thick With Gap Of 15Mm To Each Other, Over 20Mm Thick Base Of Cement Mortar 1:4 Cement And Coarse Sand Mixed With Water Proofing Compound Spreading Cement Slurry Mixed With Aerelic Cement Concrete Water Proofing Compound Filled Gaps Of Coba & Top Of Coba Mortar Mixed With Water Proofing Compound Spreading 1:4 Cement And Coarse Sand Mortar Finished Smooth & Top Mashed False Sqaure 30Cm X Cm And Side Wall Parapet Shall Be Mono Tythic Plaster Wall Upto 30 Cm Higher And Junction And Corner Shall Be Rounded By Brick Ballast Cement And Coarse Sand Mortar Coba With Top Finished Plaster Mixed With Acelic Water Proofing Compound @ 2% By Weight & Including S / O All Materials, Labour, T&P Etc Complete For Proper Completion Of Work. 24 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:6 ( 1 Cement: 6 Coarse Sand ) 25 12 Mm Cement Plaster Of Mix 1:6 ( 1 Cement: 6 Coarse Sand ) 26 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:4 ( 1 Cement: 4 Coarse Sand ) In Plinth. 27 Making Grooves 10 To 12 Mm Wide X 8 Mm Deep In Plaster Of The Wall Or In Ceiling Vertically Or Horizontally As Required 28 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. 29 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarsesand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 30 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate. 31 Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) , Finished With A Floating Coat Of Neat Cement 32 Providing & Fixing Glass Strips Of 4 Mm Thickness 3.50 Cm Depth In Joints Of Floors & Skirtings At The Time Of Laying Floors, Flash With Floor Level, Including Labour And T&P Etc. Complete. 33 Distempering One Coat With Oil Bound Distemper Of Approved Brand And Manufacture And Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over And Including A Priming Coat With Cement Primer Of Approved Brand And Manufacture Such As Berger, J&N Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Dropping And Other Foreign Matter And Also Including Prepairing The Surface Even And Sand Prepared Smooth Including Cost Of All Materials. For Every Coat After The First Coat. 34 Finishing Walls With Exterior Emulsion Paint ( Apex ) Of Approved Brand And Manufacture And Of Required Shade On Undecorated Wall Surface To Give Even Shade Over @ 1.25 Ltr / 10Sqm Including One Coat Of Primer Applied @ 0.75 Ltr / 10 Sqm Coat Curing And Cost Of All Material, Labour T&P Etc. Required For Proper Comletion Of Work For Two Coat 35 Finishing Wall With Putty Approved Brand And Manufacture And Of Required Shade On Undecorated Wall Surface To Give Even Shade Over Including Curing And Cost Of All Material, Labour T&P Etc. Required For Proper Completion Of Work 36 Providing And Fixing Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm ( + 0.05 % ) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineerin- Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X 55 Mm ) With Epdm Seal, Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.0.62 Mm Thick 37 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes 38 Painting Or Varnishing Or Iron Works In Small Areas With One Coat Of Ready Mixed In Priming Paint & Two Coat Of Approved Superior Quality Ready Mixed Paint Of Clear Synthetic Varnish Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of Work Paint To Be Used Should Confirm To The I.S.I. No. 103 1950 39 Construction Of Apron Drain ( 150Mm Wide X 150 Mm Deep ) 40 Multi Purpose Hall ( Water Supply & Sanatory Work ) 41 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 42 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap 43 Extra For Providing Opening Of Required Size & Shape For Wash Basin / Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble / Granite / Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 44 Providing And Fixing Flexible P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc Waste Fittings Complete.Flexible Pipei ) 32 Mm Dia 45 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work.90 Mm O.D. 46 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work.110 Mm O.D. 47 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.110 Mm 48 Supply And Fixing Of Upvc S.W.R. Door Bend Confirming To Is- 1473590 Mm Size 49 Supply And Fixing Of Upvc S.W.R. Door Bend Confirming To Is- 14735110 Mm Size 50 Supply And Fixing Of Upvc S.W.R. Plain Tee Confirming To Is- 1473590X90x90 Mm Size 51 Supply And Fixing Of Upvc S.W.R. Plain Tee Confirming To Is- 14735110X110x110 Mm Size 52 Supply And Fixing Of Upvc S.W.R. Plain Bend Confirming To Is- 1473590 Mm Size 53 Supply And Fixing Of Upvc S.W.R. Plain Bend Confirming To Is- 14735110 Mm Size 54 Supply And Fixing Of Upvc S.W.R. Door Y Confirming To Is- 1473590 Mm Size 55 Supply And Fixing Of Upvc S.W.R. Door Y Confirming To Is- 14735110 Mm Size 56 Supply And Fixing Of Upvc S.W.R. Cowel Confirming To Is- 1473590 Mm Size 57 Supply And Fixing Of Upvc S.W.R. Cowel Confirming To Is- 14735110 Mm Size 58 Supply And Fixin G Of Upvc S.W.R. Nahni Trap Size 100 / 75Mm, 100 / 90Mm Confirming To Is - 14735 Self Cleannig Design Fixed In Pcc 1:2:4 And Supply And Fixing Of 125Mm Dia Heavy Duty Cp Brass Jali. 59 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc.Internal Work - Exposed On Wall 25 Mm Nominal Outer Dia Pipes 60 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall25 Mm Nominal Outer Dia Pipes 61 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15 Mm Nominal Outer Dia Pipes 62 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes 63 Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. External Work40 Mm Dia, Nominal Bore 64 Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 25Mm Dia, Nominal Bore 65 Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete :25 To 40 Mm Nominal Bore 66 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 45 Cm Length15 Mm Nominal Bore 67 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint With Two Coats Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work ( Internal Work -Exposed On Walls ) 25 Mm Nominal Outer Dia Pipes 68 Painting Gi Pipes And Fittings With Two Coats Of Anti Corrosive Bitumastic Paint Of Approved Quality 40 Mm Dia, Nominal Bore 69 Providing And Filling Sand Of Grading Zone V Or Coarser Grade, Allround The G.I. Pipes In External Work 40 Mm Dia, Nominal Bore 70 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :20 Mm Nominal Bore 71 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :25 Mm Nominal Bore 72 Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Confirming To Is:893115Mm Nominal Bore 73 Providing And Fixing C.P.Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is 8931 A ) 15 Mm Nominal Bore.15 Mm Nominal Bore 74 Excavating Trenches Of Required Width For Pipes, Cables, Etc, Including Excavation For Sockets, Depth Upto 1.5 M Including Getting Out The Excavated Materials, Returning The Soil As Required In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layers By Ramming, Watering Etc. Stacking Serviceable Material For Measurements And Disposal Of Unserviceable Material As Directed, Within A Lead Of 50M : Pipes, Cables Etc. Exceeding 80 Mm Dia But Not Exceeding 300 Mm Dia. 75 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work.160 Mm O.D. 76 Providing And Laying Cement Concrete 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design : 150 Mm Diameter Pipe 77 Supply And Fixing Of Upvc S.W. R. Gully Trap Confirming To Is - 14735 Size 150X110 Mm Dia Of Self Cleaning Design Including Fixed Brick Masonary Chamber 250X250x250mm Size I / C Supply And Fixing Of Ci Cover With Frame Weight Not Less Then 4.50Kg. & Ci Grating 150X150mm Complete In All Respects. 78 Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With R.C.C. Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Fisnihed With A Floating Coat Of Neat Cement Complete As Per Standard Design : ( A ) Inside Size 900 X 800Mm And 500Mm Deep Including C.I. Cover Frame. 79 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflowpipes But Without Fittings And The Base Support For Tank. 80 Septic Tank 81 Earth Work In Excavation ( Pwd - 2.8.1 ) 82 P.C.C. In Foundation ( 1 :4 :8 ) ( Pwd -4.1.8 ) 83 1St Class B / Win Septic Tank ( 1Cement : 6 Coarse Sand ) Pwd-307A 84 R.C.C. Work In Septic Tank ( M-20 ) Pwd-284A 85 M.S. Work In R.C.C. ( D.S.R. 5.22.6-14.05% ) 86 12 Mm Thk Plastering Inside Septic Tank In 1:4 Dsr-13.5.1-14.05% 87 Providing M.S. Foot Rest Including Fixing With 20 X 20 X 10 Cm Cement Concete Block 1:3:6 ( 1 Cement : 3 Coarse :6 Graded Aggregate Of Nominal Size 20 Mm ) As Per Standard With 20X20 Mm Sqm. Bar. D.S.R.: 19.15.1-14.05% 88 Providing & Fixing Soil, Wast And Vent Pipe. 75 Mm Dia Sand Cost Iron S&S Pipe. D.S.R.: 17.35.2.1-14.05% 89 Providing & Fixing Sand Cost Iron Terminal Guard 75 Mm Dia. D.S.R. : 17.56.2.1-14.05% 90 Providing & Fixing C.I. Tee At The Inlet & Outlet Of Septic Tank. D.S.R.: 7087 91 Providing & Fixing Plane Sand Cost Iron S&S Bend Of Required Degree.D.S.R. : 17.38.2.1-14.05%75 Mm 92 Providing Lead Caulked Joints To Sand Cost Iron / Cetrifugally Cast ( Squn ) Irons Pipes & Fitting Of Dia. D.S.R. : 17.58.2-14.05% 75 Mm 93 Supply & Fixing Of Medium Quality R.C.C. Manhole Coverwith Frame Complete.Hd.-20-Circular Shape , 560 Int. Dia. D.S.R. : 19.19.3.1-14.05% 94 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. D.S.R. : 19.32.1-14.05% 95 Multipurpose Hall ( Internal Electrification Work ) 96 Point Wiring :Wiring Point For Light With 1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable In Pvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With 1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thick , Phenolic Laminated Backalite Sheet Etc.Complete In All Respect As Directed Including Matching Colour Wash. 97 Wiring Point For Fan / Fresh Air Fan ( Light Duty Exhaust Fan ) With1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable Inpvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thick , Phenolic Laminated Backelite Sheet, Etc.Complete In All Respect, As Directed, Including Matching Colour Wash. 98 Wiring Point For Plug With 1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable In Pvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting , Complete With 1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Socket Etc.Complete In All Respect, As Directed, Including Matching Colour Wash. 99 Supply Fixing & Concealing Ofpvc Conduit In The Wall Including Cutting Of Brick Laying Of Conduit & Fixing It With Ms Hooks & Then Plastering.With Cement, Sand, Mortar Finished To The Level, With Matching Colour Wash Including Cost Of Proper Thrading Of Conduit And Providing Necessary Socket , Bend & Chucknuts, As Directed By Engineer Incharge With The Supply Ofmaterial Labour And T&P Required For Proper Completion Of Work. Size 20 Mm Dia ( 2 Mm ) Thick Pvc Conduit 100 Wiring Point For Plug Point With 5 Amp Flush Type Switch And 3 Pin Socket And Earth Continuity Wire Of 1.5 Sq.Mm. Frlsh Pvc Insulated Multi Strand Copper Conductor Cable. ( Drawn Through Existing Concealed Pvc Conduit ) And Ceiling Rose / Angle / Batten Holder Fixed With 3Mm Thick Phenolic Laminated Backalite Sheet With Brass Machine Screws And Cup Washers Mounted Over Existing M.S. Switch Board Box / Junction Box With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer In Charge. 101 Add For Light / Fan Point With Moduler Type Switch In Place Of Piano Type Switch. 102 Add For Plug Point With Moduler Type Switch In Place Of Piano Type Switch. 103 Submains ( Cooper Wires ) :Supply & Wiring Of Submains With 2 Nos.1.5 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting, With1 No. 1 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 104 Supply & Wiring Of Submains With 2 Nos.2.5 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting, With1 No. 1.5 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 105 Supply & Wiring Of Submains With 2 Nos.4 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, With 1 No. 2.5 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 106 Supply & Wiring Of Submains With 2 Nos.6 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, With 1 No. 4 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 107 Supply & Wiring Of Submains With 4 Nos.10 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 40 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, With 2 No. 6 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 108 Lighting Fixtures ( Lights / Fans ) :Supply & Fixing Of Batton / Angle Holderincluding Makingconnectionetc. As Required. 109 Supply & Fixing Of Recess Mounting Round 15 To 18 Watt Led Down Lighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink , Diffuser / Reflector And Driver Set Complete In All Respect.Cat. - Aaa 110 Supply & Fixing Of Recess Mounting Round 24 To 32 Watt Led Down Lighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink , Diffuser / Reflector And Driver Set Complete In All Respect.Cat. - Aaa 111 Supply And Fixing Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 1X22 Watt Suitable For Upto 1X22 Watt Led Polycarbonate Tube Light Complete Including Tube Suitable For Both Surface & Suspended Complete In All Respect.Cat. - Aaa 112 Supply And Fixing Of 3 Watt To 6 Watt Led ( Spot Light ) Fitting Confirming To Ip 65 And Above Protection Complete In All Respect. Cat. - Aaa ( Use As A Decorative Mirror Light ) 113 Armoured Cables ( Cable / Gland / Lug ) :Supplying And Laying Ofaluminium Conductor Pvc Insulated Armoured Served Sheathed Cable 1100 Volts Grade At The Depth Of 750 Mm Bellow Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And On Top .On Surface The Cable Run Shall Be Fixed On Ms Clamps Etc.Of Suitable Size Or As Directed Bythe Engineer-Incharge , Complete In All Respect.The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Following Sizesize 16 Sq Mm X 4 Core 114 Supply And Fixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheaththed , Underground Cable Including Rubber Ring Etc. Complete In All Respect. Thearmouring Of The Cable Shall Be Properly Connected With The Earthas Per Direction Of Engineer-Incharge. For Cable Size 16 Sq Mm X 4 Core 115 Supply And Fixing Ofplain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To Cable Leadsfor Pvc Insulated & Armoured Cable Insulating With Tape And Making Connection. Complete In All Respect As Per Direction Of Engineer -Incharge. For Cable Size 16 Sq Mm 116 Dbs & Mcbs :Supply And Fixing Of 6 Amp To 32 Amp. Spmcb ( 10 Ka ) C Curve. Cat A 117 Supply And Fixing Of 40 Amp. Tp Mcb ( 10 Ka ) C Curve. Cat A 118 Supply And Fixing Of 63 Amp. Tp Mcb ( 10 Ka ) C Curve. Cat A 119 Supply And Fixing Of40 Amp. Fp Mcb ( 10 Ka ) C Curve. Cat A 120 Supply And Fixing Of 63 Amp. Fp Mcb ( 10 Ka ) C Curve. Cat A 121 Supply And Fixing Of 100 Amp. Fp Mccb ( 25 Ka ) Thermal Magnetic Releasecat A 122 Supply And Fixing Of Surface / Flush Mounting 6 Ways Tpn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. Cat A 123 Supply And Fixing Of Surface / Flush Mounting 8 Ways Tpn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. Cat A 124 Supply And Fixing Of Surface / Flush Mounting 4 Ways Vtpn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. Cat A 125 Miscellaneous Items :Supply And Fixing Of Danger Board Fabricated From 10 Gauge M.S. Sheet As Per I.E. Rules 126 Supply And Fixing Of Shock Treatment Chart Prescribedas Per I.E. Rules.Duly Framed With Glass And Supported From Back With Hard Board Or Shoft Board With Supply Of All Material , Labour, T&P For Proper Completion Of Work. 127 Supply And Laying Of 1800*900*12Mm Thick Chequerd Rubber Matting Of Tested Quality. Complete In All Respect. As Per I.E. Rules. 128 Supply And Fixing Of Power Plug With 20A / 250V Flush Type Moduler Switch And 5 Pin 20A / 250V Flush Type Universal Moduler Socket In Suitable Conceled Ms Box Including Supply Of All Material, Labour, T&P Etc.Required For Proper Completion Of Work. 129 S / F Of Hexagonal Fan Box With Hexagonal Side Of Approx 80Mm In Length Fabricated From 16Swgm.S. Sheet Incorporating 10Mm Dia, M.S. Round Barduly Bent For Supporting Fan Hanger Dully Painted Withred Oxide And Screwing Arrangement With Wiring Conduit Laid In The R.C.C. Roof Before Concreting Along With Supply Of All Materials, Labour T & P Etc., For Proper Completion Of Work. 130 Dsr Itemstelephone / Tv Outlet Sockets & Cables Etc. :Supplying And Fixing Telephone Socket Outlet Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 131 Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pair 132 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 1 Run Of Cable 133 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 134 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.1 Or 2 Module 135 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.3 Module 136 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.4 Module 137 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.6 Module 138 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.8 Module 139 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.12 Module 140 Supplying & Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, C Curve Including Connections, Painting Etc. As Required. ( For Ac Power Point / Mcb Point ) 141 Non-Schedule Itemssupply & Fixing Of 12 Watt Led Bulb - B22 / E27 ( Colour Temp.- 6500K / Lumens - 900 Lm ) Cool Day Light, Input Volts ( Ac 90V-260V ) , 3-Star Rating Suitable For Batten / Angle Holder Including Making Connection.Complete In All Respect. 142 Supply & Fixing Of 225 / 230Mm Sweep Ventilating ( Light Duty ) Exhaust Fan Complete With Metallic Blade ( Steel Bird Guard Protector / Copper Motor For High Air Suction Performance / Capacitor Etc. ) , Noise Level : ( 45 - 50 ) Db, Power Consumption : 45 W, Rated Voltage : 230 V, Rated Frequency : 50 Hz, Motor Type : Normal Speed. Complete In All Respect. 143 Supply & Fixing Of Lan Socket Outlet Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. Complete In All Respect. 144 Bio Laboratory ( Civil Work ) 145 Excavation Infoundation Inordinary Soil ( Loam Clay Or Sand ) Including Lift Upto 1.5M Lead Upto 30.0 M& Including Filling Wateringand Rammingof Excavated Earth Into The Space Between The Building & Sides Offoundation Trenches Or Into The Plinth And Removal& Disposal Surplus Earthas Directed By The Engineer I / C Within A Lead Of 30 M.From Foundation Trenches. 146 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete.. 147 Coarse Sand Filling In Plinth Including Supply Of Necessary Quantity Of Sand From A Distance Not Exceeding 8 Kms. From The Site Of Work And Including Watering, Dressing Etc Rate To Include Cost Of All Materials Labour T & P Etc Required For Proper Completion Of Work. 148 Providing And Laying Cement Concrete 1:4:8 ( 1Cement :4 Coarse Sand :8Graded Stone Ballast 40 Mm. Nominal Size ) Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work And Curing Complete, Also Including Cost Of Formwork In Foundation. 149 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Foundation Of Doors And Windows Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 150 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Plinth Beam And Band Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 151 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Columns Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) Upto Plinth Level 152 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Columns Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) Above Plinth Level Upto Fifth Floor Level 153 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Lintels Of Doors And Windows Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 154 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 155 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Beam Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 156 Class-150 Brick Work In 1:6 Cementand Coarse Sandmortar In Foundation And Plinth Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work. 157 Class-150 Brick Work In 1:6 Cementand Coarse Sandmortar In Superstructure Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work 158 Class-150 Brick Work In 1:4 Cementand Coarse Sandmortar In Superstructure Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work 159 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 160 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Apiece Of Cloth Lightly Soaked In Kerosene Oil. 161 Providing And Injecting Chemical Emulsion For Preconstructional Antitermite Treatment And Creating A Chemical Barrier Under And Alround The Coloumn Pitswall Tench Basement Excavation Top Surface If Plinth Filling Junction Of Wall And Floor Along The External Perimer Of Binding Expansion Joints, Surrounding Of Pipes And Conduits Etc.Complete ( Plinth Area Of The Building At Ground Floor Only Shall Be Measuredas Per I.S.6313 ( Part Ll 1981 ) Aldrine Emulsifiable Concrete Or Any Other Approved Material Such As Hepthachlor Or Chlordance Will Be Used.The Rate Of Application Of Chemical Emulsion Shall Be As Follows:- ( 1 ) Treatment For Masonary & Foundation 5 Litres Per Sq.M. ( 2 ) Back Fill In Immediate Contract With Foundation 7.5 Litre Per Sq.M ( 3 ) Treatment Of Top Surface Of Plinth Filling 5 Liters Per Sq.M. ( 4 ) Treatment Of Soil Along External Parameter Of Building 7.50 Lire Per Sqm. ( For Payment Plinth Area To Be Measured As Per Is Code ) . 162 Mild Steel Tmt Bars ( Fe-500 D Grade Or Higher ) Or Hysb Bars Or Iron In Plain Work Such As Reinforced Concrete Or Reinforced Brick Work ( When Not Included In An Over All Rates ) Wrought To Require Shape As Necessary Inlcuding Bending For Proper Completion Of The Work And Including Supply Of All Steel. 163 Providing And Fixing Factory Made Upvc White Colour Casement / Casement Cum Fixed Glazed Windows Comprising Of Upvc Multichambered Frame, Sash And Mullion ( Where Ever Required ) Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Upvc Extruded Glazing Beads Of Appropriate Dimension, Epdm Gasket, Stainless Steel ( Ss 304 Grade ) Friction Hinges, Zinc Alloy ( White Powder Coated ) Casement Handles, G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion ( If Required ) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes And Silicon Sealant Shall Be Paid Separately ) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Casement Cum Fixed Panel Window Having Both End Single Casement Panel, Middle Fixed Panels And At Top Completely Fixed Ventilator With S.S Friction Hinges ( 400 X 19 X 1.9 ) Made Of ( Big Series ) Frame 60 X 58 Mm, Sash 60 X 72 Mm , & T Mullion 60 X 72 Mm All Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension . ( Area Of Window Above 3.00 Sqm Upto 5.00 Sqm ) . 164 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Fine Cellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Self Tapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As Per ManufacturerS Specification And Direction Of Engineer-In-Charge 165 Supply And Fixing Flush Doorcommercial Quality Conforming To Is : 2202 Part I ( 1983 ) Including Isi Marked Oxidized Iron Fitting With Screws, Bolt, Hinges, Handles, Sliding Bolt, Door Stopper And Tower Bolt Etc.35 Mm Thick 166 Providing And Fixing Flush Doors With Decorative Veneering Instead Of Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) 167 Providing And Fixing Flush Doors With Decorative Veneering Instead Of Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) 168 Providing And Laying Brick Coba 120Mm Thick Laid With M-150 Class Brick Bat Coba 7.50 Cm Thick With Gap Of 15Mm To Each Other, Over 20Mm Thick Base Of Cement Mortar 1:4 Cement And Coarse Sand Mixed With Water Proofing Compound Spreading Cement Slurry Mixed With Aerelic Cement Concrete Water Proofing Compound Filled Gaps Of Coba & Top Of Coba Mortar Mixed With Water Proofing Compound Spreading 1:4 Cement And Coarse Sand Mortar Finished Smooth & Top Mashed False Sqaure 30Cm X Cm And Side Wall Parapet Shall Be Mono Tythic Plaster Wall Upto 30 Cm Higher And Junction And Corner Shall Be Rounded By Brick Ballast Cement And Coarse Sand Mortar Coba With Top Finished Plaster Mixed With Acelic Water Proofing Compound @ 2% By Weight & Including S / O All Materials, Labour, T&P Etc Complete For Proper Completion Of Work. 169 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:6 ( 1 Cement: 6 Coarse Sand ) 170 12 Mm Cement Plaster Of Mix 1:6 ( 1 Cement: 6 Coarse Sand ) 171 12 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:4 ( 1 Cement: 4 Coarse Sand ) In Plinth. 172 Engraving Lines In The Plaster Of The Outer Face Wall Vertically & Horizontally To Display The Surface As Stone Facing As Directed By Engineer In Charge Including Labour & T&P Etc. Required For Proper Completion Of The Work 173 Supply And Fixing 6 To 8 Thick Ivory Or Light Shades Vitrified Tiles Of Standard Make 600X600 Mm Size ( Bell / Kajaria / Somani Or Other Standard Make ) In Flooring And Skirting 1:3 Approved Cement And Coarse Sand Mortar Sand Finished With In Its Cement Color Slurry, Jointing And Polished Of Approved Quality Complete Including Suply Of All The Materials Labour Tools And Plants Etc. Required For Proper Completion Of The Work As Per Direction Of Engineer In Charge. 174 Laying Of 20 Mm Thick Kota Stone Of Size 45X45cm And Above Flooring Over Perviously Prepared Base With 2Cm Thick 1:3 ( 1 Cement: 3 Coarse Sand ) Including Filling Joints With Cement Mixed With Pigment Required For Matching The Shade Of Floor As Per The Direction Of The Engineer In Charge Including Cutting Polishing With Wax Polish Including Supply Of The Materials, Labour And T&P Etc. Required For Proper Completion Of The Work. 175 Laying Of 20 Mm Thick Kota Stone Of Size 45X45cm And Above Flooring Over Perviously Prepared Base With 2Cm Thick 1:3 ( 1 Cement: 3 Coarse Sand ) Including Filling Joints With Cement Mixed With Pigment Required For Matching The Shade Of Floor As Per The Direction Of The Engineer In Charge Including Cutting Polishing With Wax Polish Including Supply Of The Materials, Labour And T&P Etc. Required For Proper Completion Of The Work. 176 Providing & Fixing Glass Strips Of 3.15 M Thickness 3.70 Cm Depth In Joints Of Floors & Skirtings At The Time Of Laying Floors, Flash With Floor Level, Including Labour And T&P Etc. Complete. 177 Distempering One Coat With Oil Bound Distemper Of Approved Brand And Manufacture And Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over And Including A Priming Coat With Cement Primer Of Approved Brand And Manufacture Such As Berger, J&N Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Dropping And Other Foreign Matter And Also Including Prepairing The Surface Even And Sand Prepared Smooth Including Cost Of All Materials. For Every Coat After The First Coat. 178 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade: - New Work ( Two Or More Coat Applied @ 1.67 Ltr. / 10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg / 10 Sqm. 179 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 180 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate. 181 Construction Of Apron Drain ( 150Mm Wide X 150 Mm Deep ) 182 Providing And Fixing 150 Mm Bright Finished Floor Brass Door Stopper With Rubber Cushion, Necessary Brass Screws Etc. To Suit Shutter Thickness Complete. 183 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 184 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete ( A ) 250 Mm X 10Mm 185 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete ( A ) 200 Mm X 10Mm 186 Providing And Fixing Stainless Steel Handles With Screws Etc. Complete ( A ) 125 Mm 187 Laboratory ( Water Supply & Sanitation ) 188 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : Size 600X450x200 Mm 189 Extra For Providing Opening Of Required Size & Shape For Wash Basin / Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble / Granite / Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 190 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work. 110 Mm O.D. 191 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.110 Mm 192 Supply And Fixing Of Upvc S.W.R. Door Bend Confirming To Is- 1473590 Mm Size 193 Supply And Fixing Of Upvc S.W.R. Door Bend Confirming To Is- 14735110 Mm Size 194 Supply And Fixing Of Upvc S.W.R. Plain Tee Confirming To Is- 1473590X90x90 Mm Size 195 Supply And Fixing Of Upvc S.W.R. Plain Tee Confirming To Is- 14735110X110x110 Mm Size 196 Supply And Fixing Of Upvc S.W.R. Plain Bend Confirming To Is- 1473590 Mm Size 197 Supply And Fixing Of Upvc S.W.R. Plain Bend Confirming To Is- 14735110 Mm Size 198 Supply And Fixing Of Upvc S.W.R. Door Y Confirming To Is- 1473590 Mm Size 199 Supply And Fixing Of Upvc S.W.R. Door Y Confirming To Is- 14735110 Mm Size 200 Supply And Fixing Of Upvc S.W.R. Cowel Confirming To Is- 14735110 Mm Size 201 Supply And Fixin G Of Upvc S.W.R. Nahni Trap Size 100 / 75Mm, 100 / 90Mm Confirming To Is - 14735 Self Cleannig Design Fixed In Pcc 1:2:4 And Supply And Fixing Of 125Mm Dia Heavy Duty Cp Brass Jali. 202 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour Weighing Not Less Than 105 Gms. 203 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15 Mm Nominal Outer Dia Pipes 204 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes 205 Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. External Work40 Mm Dia, Nominal Bore 206 Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 25Mm Dia, Nominal Bore 207 Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete :25 To 40 Mm Nominal Bore 208 Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete :50 To 80 Mm Nominal Bore 209 Providing And Filling Sand Of Grading Zone V Or Coarser Grade, Allround The G.I. Pipes In External Work40 Mm Dia, Nominal Bore 210 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :20 Mm Nominal Bore 211 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :25 Mm Nominal Bore 212 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15Mm Nominal Bore 213 Excavating Trenches Of Required Width For Pipes, Cables, Etc, Including Excavation For Sockets, Depth Upto 1.5 M Including Getting Out The Excavated Materials, Returning The Soil As Required In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layers By Ramming, Watering Etc. Stacking Serviceable Material For Measurements And Disposal Of Unserviceable Material As Directed, Within A Lead Of 50M : Pipes, Cables Etc. Exceeding 80 Mm Dia But Not Exceeding 300 Mm Dia. 214 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work.160 Mm O.D. 215 Providing And Laying Cement Concrete 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design :150 Mm Diameter Pipe 216 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflowpipes But Without Fittings And The Base Support For Tank. 217 Laboratory ( Internal Electrification Work ) 218 Point Wiring :Wiring Point For Light With 1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable In Pvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With 1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thick , Phenolic Laminated Backalite Sheet Etc.Complete In All Respect As Directed Including Matching Colour Wash. 219 Wiring Point For Fan / Fresh Air Fan ( Light Duty Exhaust Fan ) With1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable Inpvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thick , Phenolic Laminated Backelite Sheet, Etc.Complete In All Respect, As Directed, Including Matching Colour Wash. 220 Wiring Point For Plug With 1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable In Pvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting , Complete With 1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Socket Etc.Complete In All Respect, As Directed, Including Matching Colour Wash. 221 Wiring Point For Plug Point With 5 Amp Flush Type Switch And 3 Pin Socket And Earth Continuity Wire Of 1.5 Sq.Mm. Frlsh Pvc Insulated Multi Strand Copper Conductor Cable. ( Drawn Through Existing Concealed Pvc Conduit ) And Ceiling Rose / Angle / Batten Holder Fixed With 3Mm Thick Phenolic Laminated Backalite Sheet With Brass Machine Screws And Cup Washers Mounted Over Existing M.S. Switch Board Box / Junction Box With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer In Charge. 222 Add For Light / Fan Point With Moduler Type Switch In Place Of Piano Type Switch. 223 Add For Plug Point With Moduler Type Switch In Place Of Piano Type Switch. 224 Submains ( Cooper Wires ) :Supply & Wiring Of Submains With 2 Nos.1.5 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting, With1 No. 1 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 225 Supply & Wiring Of Submains With 2 Nos.2.5 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting, With1 No. 1.5 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 226 Supply & Wiring Of Submains With 2 Nos.4 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, With 1 No. 2.5 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 227 Lighting Fixtures ( Lights / Fans ) :Supply & Fixing Of Recess Mounting Round 24 To 32 Watt Led Down Lighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink , Diffuser / Reflector And Driver Set Complete In All Respect.Cat. - Aaa 228 Supply And Fixing Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 1X22 Watt Suitable For Upto 1X22 Watt Led Polycarbonate Tube Light Complete Including Tube Suitable For Both Surface & Suspended Complete In All Respect.Cat. - Aaa 229 Supply Of Ceilling Fans With Fan Motor Of A.C. Permanent Insulation, Capacitor Rating Conforming Bee 5 Star Rating And Is:374 / 79 And Also Comply With Is:1709 / 1984 With Latest Amendment. The Rated Voltage 220 / 240 Volts, 50 Hz, 1-Ph Ac The Fan Assemble Should Consists Of Down Rod Blades, Shackle Canopies Etc And With Double Ball Bearing System.Bee 5 Star Rated-1200 Mm Sweep 230 Dbs & Mcbs :Supply And Fixing Of 6 Amp To 32 Amp. Spmcb ( 10 Ka ) C Curve. Cat A 231 Supply And Fixing Of40 Amp. Dp Mcb ( 10 Ka ) C Curve. Cat A 232 Supply And Fixing Of Surface / Flush Mounting 12 Ways Spn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. Cat A 233 Miscellaneous Items :Supply And Fixing Of Danger Board Fabricated From 10 Gauge M.S. Sheet As Per I.E. Rules 234 Erection And Testing Of Ceiling Fan And Regulator For Room Height Upto 3.5Mts. Including Supply Of 3Mm Thick G.I. Down Rod 19Mm Dia Duly Painted, Complete In All Respects. 235 Supply And Fixing Of Shock Treatment Chart Prescribedas Per I.E. Rules.Duly Framed With Glass And Supported From Back With Hard Board Or Shoft Board With Supply Of All Material , Labour, T&P For Proper Completion Of Work. 236 Supply And Fixing Of Power Plug With 20A / 250V Flush Type Moduler Switch And 5 Pin 20A / 250V Flush Type Universal Moduler Socket In Suitable Conceled Ms Box Including Supply Of All Material, Labour, T&P Etc.Required For Proper Completion Of Work. 237 S / F Of Hexagonal Fan Box With Hexagonal Side Of Approx 80Mm In Length Fabricated From 16Swgm.S. Sheet Incorporating 10Mm Dia, M.S. Round Barduly Bent For Supporting Fan Hanger Dully Painted Withred Oxide And Screwing Arrangement With Wiring Conduit Laid In The R.C.C. Roof Before Concreting Along With Supply Of All Materials, Labour T & P Etc., For Proper Completion Of Work. 238 Electronic Items :Supplyfixingofelectronic Fan Regulator ( Modular ) 120-280 V. Isimarked, On The Existing Switch Board Including Making Connetion, Required Material, Labour T / P Etc For Proper Completion Of Work To The Satisfaction Of Engineer In Charge Of Work. 239 Dsr Itemssupplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 240 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.3 Module 241 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.4 Module 242 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.8 Module 243 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.12 Module 244 Library ( Civil Work ) 245 Excavation Infoundation Inordinary Soil ( Loam Clay Or Sand ) Including Lift Upto 1.5M Lead Upto 30.0 M& Including Filling Wateringand Rammingof Excavated Earth Into The Space Between The Building & Sides Offoundation Trenches Or Into The Plinth And Removal& Disposal Surplus Earthas Directed By The Engineer I / C Within A Lead Of 30 M.From Foundation Trenches. 246 Filling By Carted Earthin Trenches, Plinth, Sides Of Foundation, Campus Etc. In Layers Not Exceeding 20 Cms In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Upto 50 M & Lift Upto 1.50 M. 247 Coarse Sand Filling In Plinth Including Supply Of Necessary Quantity Of Sand From A Distance Not Exceeding 8 Kms. From The Site Of Work And Including Watering, Dressing Etc Rate To Include Cost Of All Materials Labour T & P Etc Required For Proper Completion Of Work. 248 Providing And Laying Cement Concrete 1:4:8 ( 1Cement :4 Coarse Sand :8Graded Stone Ballast 40 Mm. Nominal Size ) Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work And Curing Complete, Also Including Cost Of Formwork In Foundation. 249 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Level :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Foundation ( M-20 ) 250 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Level : 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Plinth Beam ( M-20 ) 251 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Column ( M-20 ) Upto Plinth Level 252 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Column ( M-20 ) Above Plinth Level Upto Fifth Floor Level 253 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Lintel ( M-20 ) 254 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Slab ( M-20 ) 255 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . Beam ( M-20 ) 256 Class-150 Brick Work In 1:6 Cementand Coarse Sandmortar In Foundation And Plinth Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work. 257 Class-150 Brick Work In 1:6 Cementand Coarse Sandmortar In Superstructure Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work G.F. 258 Class-150 Brick Work In 1:4 Cementand Coarse Sandmortar In Superstructure Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work 259 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 260 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Apiece Of Cloth Lightly Soaked In Kerosene Oil. 261 Providing And Injecting Chemical Emulsion For Preconstructional Antitermite Treatment And Creating A Chemical Barrier Under And Alround The Coloumn Pitswall Tench Basement Excavation Top Surface If Plinth Filling Junction Of Wall And Floor Along The External Perimer Of Binding Expansion Joints, Surrounding Of Pipes And Conduits Etc.Complete ( Plinth Area Of The Building At Ground Floor Only Shall Be Measuredas Per I.S.6313 ( Part Ll 1981 ) Aldrine Emulsifiable Concrete Or Any Other Approved Material Such As Hepthachlor Or Chlordance Will Be Used.The Rate Of Application Of Chemical Emulsion Shall Be As Follows:- ( 1 ) Treatment For Masonary & Foundation 5 Litres Per Sq.M. ( 2 ) Back Fill In Immediate Contract With Foundation 7.5 Litre Per Sq.M ( 3 ) Treatment Of Top Surface Of Plinth Filling 5 Liters Per Sq.M. ( 4 ) Treatment Of Soil Along External Parameter Of Building 7.50 Lire Per Sqm. ( For Payment Plinth Area To Be Measured As Per Is Code ) . 262 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 263 Providing And Fixing Factory Made Upvc White Colour Casement / Casement Cum Fixed Glazed Windows Comprising Of Upvc Multichambered Frame, Sash And Mullion ( Where Ever Required ) Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Upvc Extruded Glazing Beads Of Appropriate Dimension, Epdm Gasket, Stainless Steel ( Ss 304 Grade ) Friction Hinges, Zinc Alloy ( White Powder Coated ) Casement Handles, G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion ( If Required ) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes And Silicon Sealant Shall Be Paid Separately ) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Casement Cum Fixed Panel Window Having Both End Single Casement Panel, Middle Fixed Panels And At Top Completely Fixed Ventilator With S.S Friction Hinges ( 400 X 19 X 1.9 ) Made Of ( Big Series ) Frame 60 X 58 Mm, Sash 60 X 72 Mm , & T Mullion 60 X 72 Mm All Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension . ( Area Of Window Above 3.00 Sqm Upto 5.00 Sqm ) . 264 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Fine Cellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Self Tapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As Per ManufacturerS Specification And Direction Of Engineer-In-Charge 265 Supply And Fixing Flush Doorcommercial Quality Conforming To Is : 2202 Part I ( 1983 ) Including Isi Marked Oxidized Iron Fitting With Screws, Bolt, Hinges, Handles, Sliding Bolt, Door Stopper And Tower Bolt Etc.35 Mm Thick 266 Providing And Fixing Flush Doors With Decorative Veneering Instead Of Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) 267 Providing And Fixing Flush Doors With Decorative Veneering Instead Of Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) 268 Providing And Laying Brick Coba 120 Mm Thick Laid With M-150 Class Brick Bat Coba 7.50 Cm Thick With Gap Of 15Mm To Each Other, Over 20Mm Thick Base Of Cement Mortar 1:4 Cement And Coarse Sand Mixed With Water Proofing Compound Spreading Cement Slurry Mixed With Aerelic Cement Concrete Water Proofing Compound Filled Gaps Of Coba & Top Of Coba Mortar Mixed With Water Proofing Compound Spreading 1:4 Cement And Coarse Sand Mortar Finished Smooth & Top Mashed False Sqaure 30Cm X Cm And Side Wall Parapet Shall Be Mono Tythic Plaster Wall Upto 30 Cm Higher And Junction And Corner Shall Be Rounded By Brick Ballast Cement And Coarse Sand Mortar Coba With Top Finished Plaster Mixed With Acelic Water Proofing Compound @ 2% By Weight & Including S / O All Materials, Labour, T&P Etc Complete For Proper Completion Of Work. 269 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:6 ( 1 Cement: 6 Coarse Sand ) 270 12 Mm Cement Plaster Of Mix 1:6 ( 1 Cement: 6 Coarse Sand ) 271 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:4 ( 1 Cement: 4 Coarse Sand ) In Plinth. 272 Making Grooves 10 To 12 Mm Wide X 8 Mm Deep In Plaster Of The Wall Or In Ceiling Vertically Or Horizontally As Required 273 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600X600 Mm 274 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 275 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 276 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) .Light Shade Pigment Using White Cement 277 Providing & Fixing Glass Strips Of 4 Mm Thickness 3.50 Cm Depth In Joints Of Floors & Skirtings At The Time Of Laying Floors, Flash With Floor Level, Including Labour And T&P Etc. Complete. 278 Distempering One Coat With Oil Bound Distemper Of Approved Brand And Manufacture And Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over And Including A Priming Coat With Cement Primer Of Approved Brand And Manufacture Such As Berger, J&N Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Dropping And Other Foreign Matter And Also Including Prepairing The Surface Even And Sand Prepared Smooth Including Cost Of All Materials. For Every Coat After The First Coat. 279 Finishing Walls With Exterior Emulsion Paint ( Apex ) Of Approved Brand And Manufacture And Of Required Shade On Undecorated Wall Surface To Give Even Shade Over @ 1.25 Ltr / 10Sqm Including One Coat Of Primer Applied @ 0.75 Ltr / 10 Sqm Coat Curing And Cost Of All Material, Labour T&P Etc. Required For Proper Comletion Of Work For Two Coat 280 Finishing Wall With Putty Approved Brand And Manufacture And Of Required Shade On Undecorated Wall Surface To Give Even Shade Over Including Curing And Cost Of All Material, Labour T&P Etc. Required For Proper Completion Of Work 281 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate. 282 Providing And Fixing 150 Mm Bright Finished Floor Brass Door Stopper With Rubber Cushion, Necessary Brass Screws Etc. To Suit Shutter Thickness Complete. 283 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 284 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete ( A ) 250 Mm X 10Mm 285 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete ( A ) 200 Mm X 10Mm 286 Providing And Fixing Stainless Steel Handles With Screws Etc. Complete ( A ) 125 Mm 287 Library ( Water Supply & Sanitation ) 288 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work.110 Mm O.D. 289 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm 290 Supply And Fixing Of Upvc S.W.R. Door Bend Confirming To Is- 1473590 Mm Size 291 Supply And Fixing Of Upvc S.W.R. Door Bend Confirming To Is- 14735110 Mm Size 292 Supply And Fixing Of Upvc S.W.R. Plain Tee Confirming To Is- 1473590X90x90 Mm Size 293 Supply And Fixing Of Upvc S.W.R. Plain Tee Confirming To Is- 14735110X110x110 Mm Size 294 Supply And Fixing Of Upvc S.W.R. Plain Bend Confirming To Is- 1473590 Mm Size 295 Supply And Fixing Of Upvc S.W.R. Plain Bend Confirming To Is- 14735110 Mm Size 296 Supply And Fixing Of Upvc S.W.R. Door Y Confirming To Is- 1473590 Mm Size 297 Supply And Fixing Of Upvc S.W.R. Door Y Confirming To Is- 14735110 Mm Size 298 Supply And Fixing Of Upvc S.W.R. Cowel Confirming To Is- 1473590 Mm Size 299 Supply And Fixing Of Upvc S.W.R. Cowel Confirming To Is- 14735110 Mm Size 300 Supply And Fixin G Of Upvc S.W.R. Nahni Trap Size 100 / 75Mm, 100 / 90Mm Confirming To Is - 14735 Self Cleannig Design Fixed In Pcc 1:2:4 And Supply And Fixing Of 125Mm Dia Heavy Duty Cp Brass Jali. 301 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cmcement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarsesand ) And A Coat Of Neat Cement, Rounding The Edges And Makingand Finishing The Outlet Complete. 302 Library ( Internal Electrification Work ) 303 Point Wiring :Wiring Point For Light With 1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable In Pvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With 1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thick , Phenolic Laminated Backalite Sheet Etc.Complete In All Respect As Directed Including Matching Colour Wash. 304 Wiring Point For Fan / Fresh Air Fan ( Light Duty Exhaust Fan ) With1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable Inpvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thick , Phenolic Laminated Backelite Sheet, Etc.Complete In All Respect, As Directed, Including Matching Colour Wash. 305 Wiring Point For Plug With 1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable In Pvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting , Complete With 1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Socket Etc.Complete In All Respect, As Directed, Including Matching Colour Wash. 306 Wiring Point For Plug Point With 5 Amp Flush Type Switch And 3 Pin Socket And Earth Continuity Wire Of 1.5 Sq.Mm. Frlsh Pvc Insulated Multi Strand Copper Conductor Cable. ( Drawn Through Existing Concealed Pvc Conduit ) And Ceiling Rose / Angle / Batten Holder Fixed With 3Mm Thick Phenolic Laminated Backalite Sheet With Brass Machine Screws And Cup Washers Mounted Over Existing M.S. Switch Board Box / Junction Box With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer In Charge. 307 Add For Light / Fan Point With Moduler Type Switch In Place Of Piano Type Switch. 308 Add For Plug Point With Moduler Type Switch In Place Of Piano Type Switch. 309 Submains ( Cooper Wires ) :Supply & Wiring Of Submains With 2 Nos.1.5 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting, With1 No. 1 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 310 Supply & Wiring Of Submains With 2 Nos.2.5 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slabalong With The Reinforcement Before Concreting, With1 No. 1.5 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 311 Supply & Wiring Of Submains With 2 Nos.4 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, With 1 No. 2.5 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 312 Lighting Fixtures ( Lights / Fans ) :Supply & Fixing Of Recess Mounting Round 24 To 32 Watt Led Down Lighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink , Diffuser / Reflector And Driver Set Complete In All Respect.Cat. - Aaa 313 Supply And Fixing Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 1X22 Watt Suitable For Upto 1X22 Watt Led Polycarbonate Tube Light Complete Including Tube Suitable For Both Surface & Suspended Complete In All Respect.Cat. - Aaa 314 Earthing Work :Supply And Burying Of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000Mm, Outer Pipe 48.4Mmx3.2Mm, Inner Pipe 26.9Mm X 2.6 Mm, Terminal Dia 12Mm, Coating 80-100 Micron Filled With Crystalline Conductive Mixture ( Ccm ) Having Anti Corrosive& Conductive Property With 50 Kgs Activated Soil ( Bfc ) Capable Of Reducing The Soil Resistivity With Good Mixture Of Retaining Capacity Along With 30 Cm Square C.I. Frame With Hinged Cover & Masonary Housing. ( From Electrode Terminal To Switch Board, Cost Of 25X3 G.I. Strip Will Be Extra ) Make : As Approved In U.P.P.W.D. & C.P.R.I. Certified. 315 Supply And Laying Of 25Mm X 3 Mm G.I. Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects. 316 Dbs & Mcbs :Supply And Fixing Of 6 Amp To 32 Amp. Spmcb ( 10 Ka ) C Curve. Cat A 317 Supply And Fixing Of40 Amp. Dp Mcb ( 10 Ka ) C Curve. Cat A 318 Supply And Fixing Of Surface / Flush Mounting 12 Ways Spn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. Cat A 319 Miscellaneous Items :Supply And Fixing Of Danger Board Fabricated From 10 Gauge M.S. Sheet As Per I.E. Rules 320 Supply And Fixing Of Shock Treatment Chart Prescribedas Per I.E. Rules.Duly Framed With Glass And Supported From Back With Hard Board Or Shoft Board With Supply Of All Material , Labour, T&P For Proper Completion Of Work. 321 Supply And Fixing Of Power Plug With 20A / 250V Flush Type Moduler Switch And 5 Pin 20A / 250V Flush Type Universal Moduler Socket In Suitable Conceled Ms Box Including Supply Of All Material, Labour, T&P Etc.Required For Proper Completion Of Work. 322 S / F Of Hexagonal Fan Box With Hexagonal Side Of Approx 80Mm In Length Fabricated From 16Swgm.S. Sheet Incorporating 10Mm Dia, M.S. Round Barduly Bent For Supporting Fan Hanger Dully Painted Withred Oxide And Screwing Arrangement With Wiring Conduit Laid In The R.C.C. Roof Before Concreting Along With Supply Of All Materials, Labour T & P Etc., For Proper Completion Of Work. 323 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 324 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.3 Module 325 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.4 Module 326 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.8 Module 327 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.12 Module 328 Toilet Block ( Civil Work ) 329 Excavation Infoundation Inordinary Soil ( Loam Clay Or Sand ) Including Lift Upto 1.5M Lead Upto 30.0 M& Including Filling Wateringand Rammingof Excavated Earth Into The Space Between The Building & Sides Offoundation Trenches Or Into The Plinth And Removal& Disposal Surplus Earthas Directed By The Engineer I / C Within A Lead Of 30 M.From Foundation Trenches. 330 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete.. 331 Coarse Sand Filling In Plinth Including Supply Of Necessary Quantity Of Sand From A Distance Not Exceeding 8 Kms. From The Site Of Work And Including Watering, Dressing Etc Rate To Include Cost Of All Materials Labour T & P Etc Required For Proper Completion Of Work. 332 Providing And Laying Cement Concrete 1:4:8 ( 1Cement :4 Coarse Sand :8Graded Stone Ballast 40 Mm. Nominal Size ) Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work And Curing Complete, Also Including Cost Of Formwork In Foundation. 333 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Plinth Beam And Band Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 334 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Lintels Of Doors And Windows Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 335 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 336 Rcc Work With Cement Approved Coarse Sand And 2 Cm ( 3 / 4 ) Gauge Approved Stone Ballast In The Proportion Of 1:1.5:3 In Beam Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 B.W.G.G.I Binding Wire And Including Necessary Centering And Shuttering Etc. And Alsoinlcuding Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of The Work. Binding Wire Cost Being Inlcuded In The Item. ( M-20 ) 337 Class-150 Brick Work In 1:6 Cementand Coarse Sandmortar In Foundation And Plinth Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work. 338 Class-150 Brick Work In 1:6 Cementand Coarse Sandmortar In Superstructure Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work 339 Class-150 Brick Work In 1:4 Cementand Coarse Sandmortar In Superstructure Including Supply Of All Materials, Labour Tools And Plants, Etc. Required For Proper Completetion Of The Work 340 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 341 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Apiece Of Cloth Lightly Soaked In Kerosene Oil. 342 Providing And Injecting Chemical Emulsion For Preconstructional Antitermite Treatment And Creating A Chemical Barrier Under And Alround The Coloumn Pitswall Tench Basement Excavation Top Surface If Plinth Filling Junction Of Wall And Floor Along The External Perimer Of Binding Expansion Joints, Surrounding Of Pipes And Conduits Etc.Complete ( Plinth Area Of The Building At Ground Floor Only Shall Be Measuredas Per I.S.6313 ( Part Ll 1981 ) Aldrine Emulsifiable Concrete Or Any Other Approved Material Such As Hepthachlor Or Chlordance Will Be Used.The Rate Of Application Of Chemical Emulsion Shall Be As Follows:- ( 1 ) Treatment For Masonary & Foundation 5 Litres Per Sq.M. ( 2 ) Back Fill In Immediate Contract With Foundation 7.5 Litre Per Sq.M ( 3 ) Treatment Of Top Surface Of Plinth Filling 5 Liters Per Sq.M. ( 4 ) Treatment Of Soil Along External Parameter Of Building 7.50 Lire Per Sqm. ( For Payment Plinth Area To Be Measured As Per Is Code ) . 343 Mild Steel Tmt Bars ( Fe-500 D Grade Or Higher ) Or Hysb Bars Or Iron In Plain Work Such As Reinforced Concrete Or Reinforced Brick Work ( When Not Included In An Over All Rates ) Wrought To Require Shape As Necessary Inlcuding Bending For Proper Completion Of The Work And Including Supply Of All Steel. 344 Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 250 X 16 Mm 345 Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, ( Barrel Type ) With Necessary Screws Etc. Complete : 250Mm X 10Mm . 346 Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, ( Barrel Type ) With Necessary Screws Etc. Complete : 150Mm X 10Mm . 347 Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete : 125 Mm 348 Mild Steel Or Iron Work Small Size And Section Such As Holding Down Bolts, Hold Fast, Tie Road, Grating Etc, ( When Not Included In Over All Rates ) Wrought To Required Form, Including Supply Of Steel, Bolts, Nuts And Wastage Etc And Fixing Angle Iron Door Frame 349 Mild Steel Or Iron Work Small Size And Section Such As Holding Down Bolts, Hold Fast, Tie Road, Grating Etc, ( When Not Included In Over All Rates ) Wrought To Required Form, Including Supply Of Steel, Bolts, Nuts And Wastage Etc And Fixing Window Z-Secton 350 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With 4.0 Mm Thick Glass Panes 351 Supply And Fixing Flush Doorcommercial Quality Conforming To Is : 2202 Part I ( 1983 ) Including Fixing Of Wooden Cleats And Stoppers And Including Necessary Srews To Supplied 35 Mm Thick 352 Mild Steel Or Iron Work Small Size And Section Such As Holding Down Bolts, Hold Fast, Tie Road, Grating Etc, ( When Not Included In Over All Rates ) Wrought To Required Form, Including Supply Of Steel, Bolts, Nuts And Wastage Etc And Fixing M.S. Grill & Railing 353 Providing And Laying Brick Coba 120Mm Thick Laid With M-150 Class Brick Bat Coba 7.50 Cm Thick With Gap Of 15Mm To Each Other, Over 20Mm Thick Base Of Cement Mortar 1:4 Cement And Coarse Sand Mixed With Water Proofing Compound Spreading Cement Slurry Mixed With Aerelic Cement Concrete Water Proofing Compound Filled Gaps Of Coba & Top Of Coba Mortar Mixed With Water Proofing Compound Spreading 1:4 Cement And Coarse Sand Mortar Finished Smooth & Top Mashed False Sqaure 30Cm X Cm And Side Wall Parapet Shall Be Mono Tythic Plaster Wall Upto 30 Cm Higher And Junction And Corner Shall Be Rounded By Brick Ballast Cement And Coarse Sand Mortar Coba With Top Finished Plaster Mixed With Acelic Water Proofing Compound @ 2% By Weight & Including S / O All Materials, Labour, T&P Etc Complete For Proper Completion Of Work. 354 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:6 ( 1 Cement: 6 Coarse Sand ) 355 12 Mm Cement Plaster Of Mix 1:6 ( 1 Cement: 6 Coarse Sand ) 356 12 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:4 ( 1 Cement: 4 Coarse Sand ) In Plinth. 357 Supply And Fixing 6Mm Thick China Glazed Tiles Of First Quality In Skirting Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar Finished With White Cement Slurry Jointing And Polishing Complete Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work. 358 Supply And Fixing 6 Mm Thick China White Glazed Tiles In Flooring Or In Skirting Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar Finished With White Cement Slurry Joiting And Polishing Complete Including Supply Of All Materials Labour And Tools Etc, Required For Completion Of The Work. ( Size Of Tiles Upto 200 X 300 ) 359 Laying Of 20 Mm Thick Kota Stone Of Size 45X45cm And Above Flooring Over Perviously Prepared Base With 2Cm Thick 1:3 ( 1 Cement: 3 Coarse Sand ) Including Filling Joints With Cement Mixed With Pigment Required For Matching The Shade Of Floor As Per The Direction Of The Engineer In Charge Including Cutting Polishing With Wax Polish Including Supply Of The Materials, Labour And T&P Etc. Required For Proper Completion Of The Work. 360 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate.In Apron 361 Construction Of Apron Drain ( 150Mm Wide X 150 Mm Deep ) 362 Providing And Fixing Glass Strips In Joints Of Terrazo / Cement Concrete Floors.40 Mm Wide And 4 Mm Thick 363 Distempering One Coat With Oil Bound Distemper Of Approved Brand And Manufacture And Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over And Including A Priming Coat With Cement Primer Of Approved Brand And Manufacture Such As Berger, J&N Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Dropping And Other Foreign Matter And Also Including Prepairing The Surface Even And Sand Prepared Smooth Including Cost Of All Materials. For Every Coat After The First Coat. 364 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade: - New Work ( Two Or More Coat Applied @ 1.67 Ltr. / 10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg / 10 Sqm. 365 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 366 Painting Or Varnishing Or Iron Works In Small Areas With One Coat Of Ready Mixed In Priming Paint & Two Coat Of Approved Superior Quality Ready Mixed Paint Of Clear Synthetic Varnish Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of Work Paint To Be Used Should Confirm To The I.S.I. No. 103 1950 367 Painting Or Varnishing Or Wood Works In Small Areas With One Coat Of Ready Mixed In Priming Paint & Two Coat Of Approved Superior Quality Ready Mixed Paint Of Clear Synthetic Varnish Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of Work Paint To Be Used Should Confirm To The I.S.I. No. 103 1950 368 Toilet Block ( Water Supply & Sanitation ) 369 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 370 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 371 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap 372 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm And 340X410x265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern 373 Range Of Three Urinal Basins With 10Litre White P.V.C. Automatic Flushing Cistern 374 Providing & Fixing Stone Slab Table Rubbed, Edges Rounded And Polished Of Size 75 X 50Cm Deep And 1.8 Cm Thick Fixed In Urinal Patitions By Cutting Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In Chase With Epoxy Grout Or With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregste 6Mm Nominal Size ) As Per Engineer-In-Charge And Finished Smoothgranite Stone Of Approved Shade 375 Providing And Fixing Flexible P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc Waste Fittings Complete.Flexible Pipei ) 32 Mm Dia 376 Providing And Fixing Ptmt Bottle Trap For Wash Basin And Sink. Bottle Trap 31 Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Centre Of The Waste Coupling 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 260 Gms. 377 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work.90 Mm O.D. 378 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work.110 Mm O.D. 379 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm 380 Supply And Fixing Of Upvc S.W.R. Door Bend Confirming To Is- 14735 90 Mm Size 381 Supply And Fixing Of Upvc S.W.R. Door Bend Confirming To Is- 14735 110 Mm Size 382 Supply And Fixing Of Upvc S.W.R. Plain Tee Confirming To Is- 14735 90X90x90 Mm Size 383 Supply And Fixing Of Upvc S.W.R. Plain Tee Confirming To Is- 14735 110X110x110 Mm Size 384 Supply And Fixing Of Upvc S.W.R. Plain Bend Confirming To Is- 1473590 Mm Size 385 Supply And Fixing Of Upvc S.W.R. Plain Bend Confirming To Is- 14735 110 Mm Size 386 Supply And Fixing Of Upvc S.W.R. Door Y Confirming To Is- 14735 90 Mm Size 387 Supply And Fixing Of Upvc S.W.R. Door Y Confirming To Is- 14735 110 Mm Size 388 Supply And Fixing Of Upvc S.W.R. Cowel Confirming To Is- 14735 90 Mm Size 389 Supply And Fixing Of Upvc S.W.R. Cowel Confirming To Is- 14735 110 Mm Size 390 Supply And Fixin G Of Upvc S.W.R. Nahni Trap Size 100 / 75Mm, 100 / 90Mm Confirming To Is - 14735 Self Cleannig Design Fixed In Pcc 1:2:4 And Supply And Fixing Of 125Mm Dia Heavy Duty Cp Brass Jali. 391 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour Weighing Not Less Than 105 Gms. 392 Providing & Fixingptmt Towel Ring Trapezoidal Shape 215 Mm Long 200 Mm Wide With Minimum Distance Of 37 Mm From Wall Face With Concealedfittings Arrangement Of Approved Quality And Colour Weighing Not Less Than 88 Gms 393 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 394 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc.Internal Work - Exposed On Wall 25 Mm Nominal Outer Dia Pipes 395 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall25 Mm Nominal Outer Dia Pipes 396 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15 Mm Nominal Outer Dia Pipes 397 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes 398 Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. External Work40 Mm Dia, Nominal Bore 399 Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 25Mm Dia, Nominal Bore 400 Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete :25 To 40 Mm Nominal Bore 401 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions :45 Cm Length15 Mm Nominal Bore 402 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint With Two Coats Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work ( Internal Work -Exposed On Walls ) 25 Mm Nominal Outer Dia Pipes 403 Painting Gi Pipes And Fittings With Two Coats Of Anti Corrosive Bitumastic Paint Of Approved Quality 40 Mm Dia, Nominal Bore 404 Providing And Filling Sand Of Grading Zone V Or Coarser Grade, Allround The G.I. Pipes In External Work40 Mm Dia, Nominal Bore 405 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :20 Mm Nominal Bore 406 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :25 Mm Nominal Bore 407 Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Confirming To Is:893115Mm Nominal Bore 408 Providing And Fixing C.P.Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is 8931 A ) 15 Mm Nominal Bore. 409 Excavating Trenches Of Required Width For Pipes, Cables, Etc, Including Excavation For Sockets, Depth Upto 1.5 M Including Getting Out The Excavated Materials, Returning The Soil As Required In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layers By Ramming, Watering Etc. Stacking Serviceable Material For Measurements And Disposal Of Unserviceable Material As Directed, Within A Lead Of 50M : Pipes, Cables Etc. Exceeding 80 Mm Dia But Not Exceeding 300 Mm Dia. 410 Supply And Fixing Of Upvc S.W.R. Pipe Type -B Confirming To Is- 13592 Including Jointing The Pipes With Rubber Ring, Lubricant And Upvc Swr Cuplar Confirming To Is - 14735. Also Including Excavation Of Trenches Cutting Of Walls And Holes And Repairing The Walls Floors And Refilling The Trenches As Before But Excluding Supply And Cost Of Other Fittings Such As Elbow, Bead, Tee And Y-Tee Including Supply Of All Material Labour And T&P .Required For Proper Completion Of The Work. 160 Mm O.D. 411 Providing And Laying Cement Concrete 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design :150 Mm Diameter Pipe 412 Supply And Fixing Of Upvc S.W. R. Gully Trap Confirming To Is - 14735 Size 150X110 Mm Dia Of Self Cleaning Design Including Fixed Brick Masonary Chamber 250X250x250mm Size I / C Supply And Fixing Of Ci Cover With Frame Weight Not Less Then 4.50Kg. & Ci Grating 150X150mm Complete In All Respects. 413 Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With R.C.C. Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Fisnihed With A Floating Coat Of Neat Cement Complete As Per Standard Design : ( A ) Inside Size 900 X 800Mm And 500Mm Deep Including C.I. Cover Frame. 414 Extra Over Item No. 24.27 For Every Additional Depth Of 0.10 Metre Or Part There Of Main Hole. ( A ) Size 900 X 800 Mm 415 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflowpipes But Without Fittings And The Base Support For Tank. 416 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 417 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 110 Mm Diameter 418 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm 419 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Coupler110 Mm 420 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion.Bend 87.5°110 Mm Bend 421 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Shoe ( Plain ) 110 Mm Shoe 422 Providing And Fixing To The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. 423 Toilet Block ( Internal Electrification Work ) 424 Point Wiring :Wiring Point For Light With 1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable In Pvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With 1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thick , Phenolic Laminated Backalite Sheet Etc.Complete In All Respect As Directed Including Matching Colour Wash. 425 Wiring Point For Fan / Fresh Air Fan ( Light Duty Exhaust Fan ) With1.5 Sq.Mmfrlsh Pvc Insulated Multistrand Single Core Copper Conductorcable Inpvc Conduit Pipe Partly Concealed In The Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With1.5Sqmm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductorcable As Earth Continuity Wire , Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thick , Phenolic Laminated Backelite Sheet, Etc.Complete In All Respect, As Directed, Including Matching Colour Wash. 426 Wiring Point For Plug Point With 5 Amp Flush Type Switch And 3 Pin Socket And Earth Continuity Wire Of 1.5 Sq.Mm. Frlsh Pvc Insulated Multi Strand Copper Conductor Cable. ( Drawn Through Existing Concealed Heavy Guage Rigid Steel Conduit ) And Ceiling Rose / Angle / Batten Holder Fixed With 3Mm Thick Phenolic Laminated Backalite Sheet With Brass Machine Screws And Cup Washers Mounted Over Existing M.S. Switch Board Box / Junction Box With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer In Charge. 427 Add For Light / Fan Point With Moduler Type Switch In Place Of Piano Type Switch. 428 Add For Plug Point With Moduler Type Switch In Place Of Piano Type Switch. 429 Submains ( Cooper Wires ) :Supply & Wiring Of Submains With 2 Nos.1.5 Sq.Mmfrlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Diaheavy Duty ( 2 Mm Thick ) Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, With1 No. 1.5 Sqmm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire Including Matching Colour Wash Etc.Complete In All Respect. 430 Lighting Fixtures ( Lights / Fans ) :Supply & Fixing Of Batton / Angle Holderincluding Makingconnectionetc. As Required. 431 Supply And Fixing Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 1X22 Watt Suitable For Upto 1X22 Watt Led Polycarbonate Tube Light Complete Including Tube Suitable For Both Surface & Suspended Complete In All Respect.Cat. - Aaa 432 Armoured Cables ( Cable / Gland / Lug ) :Supplying And Laying Ofaluminium Conductor Pvc Insulated Armoured Served Sheathed Cable 1100 Volts Grade At The Depth Of 750 Mm Bellow Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And On Top .On Surface The Cable Run Shall Be Fixed On Ms Clamps Etc.Of Suitable Size Or As Directed Bythe Engineer-Incharge , Complete In All Respect.The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Following Size Size 6 Sq Mm X 2 Core 433 Supply And Fixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheaththed , Underground Cable Including Rubber Ring Etc. Complete In All Respect. Thearmouring Of The Cable Shall Be Properly Connected With The Earthas Per Direction Of Engineer-Incharge. For Cablesize 6 Sq Mm X2 Core 434 Supply And Fixing Ofplain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To Cable Leadsfor Pvc Insulated & Armoured Cable Insulating With Tape And Making Connection. Complete In All Respect As Per Direction Of Engineer -Incharge. For Cablesize 6 Sq Mm 435 Dbs & Mcbs :Supply And Fixing Of 6 Amp To 32 Amp. Spmcb ( 10 Ka ) C Curve. Cat A 436 Supply And Fixing Of40 Amp. Dp Isolator Cat A 437 Supply And Fixing Of Surface / Flush Mounting 4 Ways Spn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. Cat A 438 Telephone / Tv Outlet Sockets & Cables Etc. :Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 439 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.6 Module 440 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal / Gp Boxes Etc. As Required.12 Module 441 Non-Schedule Itemssupply & Fixing Of 12 Watt Led Bulb - B22 / E27 ( Colour Temp.- 6500K / Lumens - 900 Lm ) Cool Day Light, Input Volts ( Ac 90V-260V ) , 3-Star Rating Suitable For Batten / Angle Holder Including Making Connection.Complete In All Respect.

Key Value

Document Fees
INR 3540 /-
EMD
INR 168000.0 /-
Tender Value
INR 80.03 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail