Tender For Pipe Line Crossing Across Bharatmala Road At Takli Medium Irrigation Project Ramganjmandi Distt,- Kota
Tender Overview
Project Description
Tender For Pipe Line Crossing Across Bharatmala Road At Takli Medium Irrigation Project Ramganjmandi Distt, - Kota
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Mar-2024 | Date Extend | Date | 22-Apr-2024 |
| 2 | 19-Apr-2024 | 001-Date Corrigendum | Date | 13-May-2024 |
| 3 | 13-May-2024 | Date Corrigendum00 | Date | 05-Jun-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | Manufacturing, supplying, lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates I coils, confirming to IS 3589-200 I or its latest revision / amendmendment, for following thickness and inside diameter including all taxes, transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-Charge; (excluding earthwork, internal lining and outer coating).Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Outerdia of pipe 355.6 mm and thickness 5mm |
| 2 | Manufacturing, supplying, lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates I coils, confirming to IS 3589-200 I or its latest revision / amendmendment, for following thickness and inside diameter including all taxes, transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-Charge; (excluding earthwork, internal lining and outer coating).Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Outerdia of pipe 457.00 mm and thickness 7.1mm |
| 3 | Manufacturing, supplying, lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates I coils, confirming to IS 3589-200 I or its latest revision / amendmendment, for following thickness and inside diameter including all taxes, transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-Charge; (excluding earthwork, internal lining and outer coating).Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Outerdia of pipe 610.00 mm and thickness 8.8 mm |
| 4 | Manufacturing, supplying, lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates I coils, confirming to IS 3589-200 I or its latest revision / amendmendment, for following thickness and inside diameter including all taxes, transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-Charge; (excluding earthwork, internal lining and outer coating).Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Outerdia of pipe 711 mm and thickness 10mm |
| 5 | Supply laying and Pushing of MS casing pipe of specified thickness approved by concerned departmental authority by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth for crossing CD works / embankments in all respect, including excavationof driven pit and exit pit ( depth up to 3 meter) with proper protection. Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing, requirement, approved by authority, specification and the direction of the Engineer. Apply corrosion resistant, protection on inside and outside of casing pipe as per technical specification. Note:- This item is to be used for Railway / NH / Express way crossings only In all type of soils 700 mm dia 10 mm thick casing pipe |
| 6 | Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum |
| 7 | Natural Sand (Un-screened) including all lead and lift. |
| 8 | Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excludingthe cost of centering, shuttering and reinforcement. Well graded crusherbroken stone aggregate of maximum size upto;20mm |
| 9 | Brick masonry (using well burnt clay bricks of size 230x 110x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 |
| 10 | Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materialsof thickness: 20 mm |
| 11 | Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excludingthe cost of centering, shuttering and reinforcement. Well graded crusherbroken stone aggregate of maximum size upto;20mm |
| 12 | Side shuttering including propping etc. complete (to achieve finish F 2 for : Block joints of foundation stilling basins buckets, aprons etc.(non -suspended horizontallylaid mass concrete) |
| 13 | Supplying of M.S. reinforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts using.Tor or ribbed bars (IS :1786) |
| 14 | Providing and fixing of Reinforced Ferro-Cement Drain cover designed of class \"A\" & \"AA\" loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti-corrosive bitumen painted M.S. plate, Rim and on M.S. lifting hooks, admixture like plasticizer bond-improving compound, shrinkage resistance compound, abrasion resistant complete as per approved design etc.Span 1201 mm to 1500 mm Standard Size 2100x 500 mm |
| 15 | Providing and making inner cement mortar lining to M.S. Pipes with mechanical devices in cement mortar 1:1 proportion , including cost of all materials, labour, special sand required, machinery, power generation, all equipments, including carrying out \"C\" value performance test of pipeline, including field joints at site complete as per technical specification and direction of Engineer in In charge. 9 mm thick for pipes up to 700 mm dia |
| 16 | Providing and applying DFBE ( Dual Layer Fusion Bonded Epoxy) Coating to the external surface of M.S. Pipes conforming to Canadian Standard CSA Z 245.20-10, consisting of 1st layer of (FBE) Fusion Bonded Epoxy powder and 2nd layer also of FBE powder as Abrasion Resistant Overcoat (ARO) including preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501- 1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2 including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Minimum thickness of coating shall be 600 micron |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender