}

Tender For Providing Facade Lighting Arrangement For Sector 18 Underpass, Noida, noida-Uttar Pradesh

New Okhla Industrial Development Authority-NOIDA has published Tender For Providing Facade Lighting Arrangement For Sector 18 Underpass, Noida. Submission Date for this Tender is 07-03-2024. Decoration Work Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42617518
Tender For Providing Facade Lighting Arrangement For Sector 18 Underpass, Noida
Open Tender
Indian
Uttar Pradesh
noida
07-03-2024

Tender Details

Providing Facade Lighting Arrangement For Sector 18 Underpass, Noida- 1 Sitc Of Outdoor Architectural 600Mm Led Non Integral Linear Wallwash Luminaire With System Wattage Not More Than 20W, System Efficacy =45Lpw, Cct Rgbw ( W=3000K ) With 4In1 Led Chip For Uniform Illumination Ensuring Every Led In Luminaire Reproducing Same Color At All Time, System Lumen Output Should Not Be Less Than 900Lm ( ±10% ) With All Rgbw Channels On, Fixture Should Be Compatible With Dmx512 And Able To Reproduce 16Million Colors With 256Step Dimming, Fixture Should Be Compatible With Non-Integral 24V Dc Cv Driver Placed In Ip Rated Box , Single Piece Housing Made Of Extruded Aluminium With Aluminium End Caps Ensuring Optimum Thermal Management, Heat Resistant Clear Tempered Glass With Secondary Pmma Lens With Available Precisebeam Angles10°X30° . Ingress Protection = Ip66 With Impact Resistance = Ik05.Remote Type Driver Should Be High Efficiency Isolated Constant Voltage Driver With Protection Class 1. Fixture Should Have Inbuilt 4 Channel Decoder. 2 Total Surge Protection Of 6Kv Internal &20Kv Or More Additional Spd, No-Load Protection, Over Voltage Protection, & Short Circuit Protection, Life 60, 000 B Hrs@L70, Cri>80 ( For While Led ) , Thd<10% , Pf>0.95, Voltagerange 140-270V Ac, Operating Temp 0 To +50°C, Operating Humidity 10-90%, Fixture Weight Should Not Be More Than3kg ( ±5% ) To Avoid Excessive Load On Facade Structure. Fixture Should Come With Min. 0.5Mtr. Long Loop In Loop Out Cable With =Ip66 Connector, Light Engine Pcb Should Be Metal Core Pcb Made Of High Grade Al 5052 With =70 Micron Copper Thickness &2 W / Mk Thermal Conductivity For Better Life & Thermal Maintenance For Light Engines. Manufacturer Emblem / Logo Embossed Into The Aluminium Housing / End Caps To Allow Oem Identification & Traceability Till The Life Of The Fixture. 3 Suitable For Mounting On Surface Using Inbuilt Mounting Brackets With >180° Tilt Adjustment At Site . Contractor Should Make Necessary Provisions For Proper Installation Of Luminaires At Site With Exceptional Workmanship Considering All Safety Standards. Luminaire Dimensions For Ref.L=1200Mm, W=60Mm ( ±5% ) , H=60Mm ( ±5% ) .Manufacturer Should Have Bis With R No. , Lm79 From Nabl Accredited Lab, Ttc From Nabl Accredited Lab, Lm80, Photometric & Illumination Code Diagram, Technical Data Sheet Soft Copy For Submission If Requested By Engineer In-Charge. Fixture Should Have Silver Grey / Black ( As Per Selection By Engineer In-Charge ) Nano Technology Powder Coating , Luminaire Should Comply With Performance & Safety Standards Iec 60598 / Iec60950 , Iec 60529, Is 10322-5, Is 161-03 / 05 / 06 / 07, Surge : Iec 61000-4-5, Emc : En 55015 ( Make: Color Kinetics / Lt / Unilamp / Traxon / Thorn ) 4 Sitc Of Outdoor Architectural 1200Mm Led Non Integral Linear Wallwash Luminaire With System Wattage Not More Than 30W, System Efficacy =45Lpw, Cct Rgbw ( W=3000K ) With 4In1 Led Chip For Uniform Illumination Ensuring Every Led In Luminaire Reproducing Same Color At All Time, System Lumen Output Should Not Be Less Than 1800Lm ( ±10% ) With All Rgbw Channels On, Fixture Should Be Compatible With Dmx512 And Able To Reproduce 16Million Colors With 256Step Dimming, Fixture Should Be Compatible With Non-Integral 24V Dc Cv Driver Placed In Ip Rated Box , Single Piece Housing Made Of Extruded Aluminium With Aluminium End Caps Ensuring Optimum Thermal Management, Heat Resistant Clear Tempered Glass With Secondary Pmma Lens With Available Precisebeam Angles10°X30° . Ingress Protection = Ip66 With Impact Resistance = Ik05.Remote Type Driver Should Be High Efficiency Isolated Constant Voltage Driver With Protection Class 1. Fixture Should Have Inbuilt 4 Channel Decoder. Total Surge Protection Of 6Kv Internal &20Kv Or More Additional Spd, No-Load Protection, Over Voltage Protection, & Short Circuit Protection, Life 60, 000 B Hrs@L70, Cri>80 ( For While Led ) , Thd<10% , Pf>0.95, Voltagerange 140-270V Ac, Operating Temp 0 To +50°C, Operating Humidity 10-90%, Fixture Weight Should Not Be More Than3kg ( ±5% ) To Avoid Excessive Load On Facade Structure. Fixture Should Come With Min. 0.5Mtr. Long Loop In Loop Out Cable With =Ip66 Connector, Light Engine Pcb Should Be Metal Core Pcb Made Of High Grade Al 5052 With =70 Micron Copper Thickness &2 W / Mk Thermal Conductivity For Better Life & Thermal Maintenance For Light Engines. 5 Manufacturer Emblem / Logo Embossed Into The Aluminium Housing / End Caps To Allow Oem Identification & Traceability Till The Life Of The Fixture. Suitable For Mounting On Surface Using Inbuilt Mounting Brackets With >180° Tilt Adjustment At Site . Contractor Should Make Necessary Provisions For Proper Installation Of Luminaires At Site With Exceptional Workmanship Considering All Safety Standards. Luminaire Dimensions For Ref.L=1200Mm, W=60Mm ( ±5% ) , H=60Mm ( ±5% ) .Manufacturer Should Have Bis With R No. , Lm79 From Nabl Accredited Lab, Ttc From Nabl Accredited Lab, Lm80, Photometric & Illumination Code Diagram, Technical Data Sheet Soft Copy For Submission If Requested By Engineer In-Charge. Fixture Should Have Silver Grey / Black ( As Per Selection By Engineer In-Charge ) Nano Technology Powder Coating , Luminaire Should Comply With Performance & Safety Standards Iec 60598 / Iec60950 , Iec 60529, Is 10322-5, Is 161-03 / 05 / 06 / 07, Surge : Iec 61000-4-5, Emc : En 55015 ( Make: Color Kinetics / Lt / Unilamp / Traxon / Thorn ) 6 Sitc Ofoutdoor Architectural Led Circular Projector Flood Light With System Wattage Not More Than 50W, System Efficacy>45Lpw ( ±5% ) , Cct Rgbw ( W=3000K ) With 4In1 Led Chip For Uniform Illumination Ensuring Every Led In Luminaire Reproducing Same Color At All Time. System Lumen Output Should Not Be Less Than 2160Lm ( ±10% ) With All Rgbw Channels On. Fixture Should Have Integral Driver & 4 Channel Decoder, Fixture Should Be Compatible For Dmx512and Able To Reproduce 16Million Colors With 256Step Dimming, . Housing Should Be Pdc Aluminium Alloy Ensuring Optimum Thermal Management , Fixture Should Be Available In Clear Optics Withpossible Beam Angles 15° ( As Per Approved Concept & Site Requirement ) . Secondarylens Should Be Of Pmma Material &Covered With Heat Resistance Toughened Glass Cover, Hinge Design Should Be Easily Adjustable With Precision Dial Feature For >90° Tilt Angle Adjustment, Ingress Protection Should Not Be Less Than Ip66, Impact Resistance Should Be Ik08 Or More.Fixture Height Should Be Approx. 261 Mm ( ±10% ) With Normal Horizontal Tilt Position. Dia Should Not Be200mm ( ±10% ) Fixture Should Be Surface / Wall Mounted As Per Site Requirement. Driver Should Have Integral Type Isolated Driver Supplied Along With Fixture. Total Inbuilt And Additional Surge Protection Of More Than Or Equal To 6Kv Internal + 20Kv Additional Spd Along With Other Necessary Protections No Load Protection, Over Voltage Protection, Short Circuit Protection. 7 Led Life Should Be 50, 000 B Hrs@L70 B10, Thd Should Be Less Than 10% , Pf>0.95, Operating Voltage Range 140-270V Ac, Operating Ambient Temp 0 To +50°C, Operating Humidity 10-90%. Fixture Should Have Antiglare Hood With Same Housing Color. Fixture Weight Should Not Be More Than 3.2Kg ( ±10% ) Ensuring Material & Built Quality.Light Engine Pcb Should Be Metal Core Pcb Made Of High Grade Al 5052 With =70 Micron Copper Thickness &2 W / Mk Thermal Conductivity For Better Life & Thermal Maintenance For Light Engines. Fixture Should Be Compatible For Loop In Loop Out Arrangement. Powder Coating Should Be Corrosion Resistant Nano Technology Powder Coating In Silver Grey Colour. Standard Power Cable Should Have Ip67 Connector. Technical Data Sheet, Type Test Certificatefrom In-House Nabl Accredited Lab Should Be Submitted On Request. Manufacturer / Oem Emblem / Logo Should Be Embossed Into The Aluminium Housing To Allow Identification Of Oem & Traceability Till The Life Of The Fixture. Luminaire Should Comply With Performance & Safety Standards Iec 60598 / Iec60950 , Iec 60529, Is 10322-5, Is 161-03 / 05 / 06 / 07, Surge : Iec 61000-4-5, Emc : En 55015 ( Make: Color Kinetics / Lt / Unilamp / Traxon / Thorn ) 8 Sitc Ofoutdoorledsystem Wattage Not More Than 80W, System Efficacy>100Lpw ( ±5% ) , Cct=3000Kfor Uniform Illumination Ensuring Every Led In Luminaire Reproducing Same Color At All Time.Fixture Should Have Integral Driver Fixture Should Be Compatible For Dmx512 .Housing Should Be Extruded Aluminium Alloyensuring Optimum Thermal Management , Fixture Should Be Available In Diffused Optics ( As Per Approved Concept & Site Requirement ) . Secondarylens Should Be Of Pmma Material &Covered With Heat Resistance Toughened Glass / Pc Cover, Ingress Protection Should Not Be Less Than Ip66, Impact Resistance Should Be Ik08 Or More. Total Inbuilt And Additional Surge Protection Of More Than Or Equal To 6Kv Internal + 20Kv Additional Spd Along With Other Necessary Protections No Load Protection, Over Voltage Protection, Short Circuit Protection. Led Life Should Be 50, 000 B Hrs@L70 B10, , Pf>0.95, Operating Voltage Range 140-270V Ac, Operating Ambient Temp 0 To +50°C, Operating Humidity 10-90% Powder Coating Should Be Corrosion Resistant Nano Technology Powder Coating In Silver Grey Colour. Standard Power Cable Should Have Ip67 Connector. Technical Data Sheet, Type Test Certificatefrom In-House Nabl Accredited Lab Should Be Submitted On Request. 9 Manufacturer / Oem Emblem / Logo Should Be Embossed Into The Aluminium Housing To Allow Identification Of Oem & Traceability Till The Life Of The Fixture. Luminaire Should Comply With Performance & Safety Standards Iec 60598 / Iec60950 , Iec 60529, Is 10322-5, Is 161-03 / 05 / 06 / 07, Surge : Iec 61000-4-5, Emc : En 55015 ( Make: Color Kinetics / Lt / Unilamp / Traxon / Thorn ) 10 Supply, Installation, Testing & Commissioining Ofuniverse ( 1024 Channels ) Dmx Controller With Following Features & Specifications: This Is Built On The Latest Generation Of Lighting Controllers And Combines All Recent Innovations. Designed For Din Rail Mounting, This Is The Perfect Solution For Midrange Lighting Installations. Delivered With 1024 Dmx Channels.The Lighting Levels, Color And Effects Can Be Programmed From A Pc, Mac, Android, Ipad Or Iphone Using Software From Our Website.ItS Key Features Includes • Dmx Stand Alone Controller • Up To 2 X Dmx512 Universes ( 1024 Channels ) • Rdm Compatible • Usb & Ethernet Connectivity For Programming / Control • Stand Alone Mode With 99 Scenes • Play Scenes In 5 Areas / Zones • Microsd Slot • 8+3 Dry Contact Trigger Ports • Test Scenes Rotary Switch • Windows / Mac Software To Set Dynamic Colors / Effects • 11 Iphone / Ipad / Android Remote And Programming Apps •Cloud Compatibility.Technical Data Input Power 12V Dc ( 8-15V Range ) , Output Protocol Dmx512 , Programmability Pc, Mac, Android, Ios, Connections-Usb-C Ethernet Screw Terminals Fordmx / Rdm Universes, 8+3 Contact Ports, 12V Power-In Battery Holder ( Cr2032 ) , Microsd Slot Memory Sd Card , Environment Ip20 / To 0 To +50°C, Buttons Rotary Switch , Os Requirements Mac Os X 10.8-10.14 Windows 7 / 8 / 10 Standards Ce, Etl, Low Voltage, Emc, And Rohs Compliance With 5 Year Warantycomplete In All Respect As Per Direction Of E / I. 12 Programming & Commisioning Charges Of Above All Lights With Different Scenes Complete In All Respect As Per Approved By Noida Officials. 13 Supply, Installation, Testing & Commissioining Of 3Port Dmx Splitter ( Din Rail Mountable ) With Following Features & Specifications:Dmx Signal Splitter Enables Branching In Complex Dmx Installations. The Combination Of A Large Number Of Receivers In Series Can Be Troublesome, Therefore It Was Possible To Create Branching Dmx Tracks Using A Splitter.With Splitter, It Possible To Split The Dmx Input Signal Into 6 Independent Branches. The Individual Outputs Are Galvanically Isolated From Input And Between Each Other. The Output Signals Are Appropriately Reinforces, Which Guarantees Correct Operation Of The Entire Installation. Dmx Splitter Is Manufactured In A Housing Adapted For Mounting On Standard Din 35Mm Rails. Specification - Power Supply-Dc12- 24V, Dmx Channels--512, Nos. Of Dmx Inout-1 & Output-6, Optical Isolation Of Dmx Lines, Built-In Terminatior, Breakdown Voltage Of The Isolation>1000V, Current Consumption-<500Mawith 5 Year Warantycomplete In All Respect As Per Direction Of E / I. 14 Supply, Installation, Testing & Commissioining Of 2 Port Dmx Splitter ( Din Rail Mountable ) With Following Features & Specifications: Dmx Signal Splitter Enables Branching In Complex Dmx Installations. The Combination Of A Large Number Of Receivers In Series Can Be Troublesome, Therefore It Was Possible To Create Branching Dmx Tracks Using A Splitter.With Splitter, It Possible To Split The Dmx Input Signal Into 6 Independent Branches. The Individual Outputs Are Galvanically Isolated From Input And Between Each Other. The Output Signals Are Appropriately Reinforces, Which Guarantees Correct Operation Of The Entire Installation. Dmx Splitter Is Manufactured In A Housing Adapted For Mounting On Standard Din 35Mm Rails. Specification - 15 Power Supply-Dc12- 24V, Dmx Channels--512, Nos. Of Dmx Inout-1 & Output-2, Optical Isolation Of Dmx Lines, Built-In Terminatior, Breakdown Voltage Of The Isolation>1000V, Current Consumption-<500Mawith 5 Year Warantycomplete In All Respect As Per Direction Of E / I. 16 Supply , Installation , Testing & Commissioning Of 4 Core .5 Sq Mm Dmx Cable Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Existing Surface / Recessed Pvc Conduit As Required. 17 Supply , Installation , Testing & Commissioning Of 3 Core 2.5 Sq Mm Wire Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 18 Operation And Maintenance Of Above All Lights, Controller, Splitters And Other All Equipments Installed By Working Agencies Including Replacing Of Defective Lights And Other Parts, Changing Of Design And Defect Libeality Period With Theft Liabelity Also Complete For 2Nd Year. 19 Operation And Maintenance Of Above All Lights, Controller, Splitters And Other All Equipments Installed By Working Agencies Including Replacing Of Defective Lights And Other Parts, Changing Of Design And Defect Libeality Period With Theft Liabelity Also Complete For 3Rd Year. 20 Supply And Laying Of 40 Mm Dia Heavy Duty ( 2Mm Thick ) Pvc Conduit Complete With Bends And Other Acessories As Required And 14 Swg Fish Steel Wire Etc. In Slab Alongwith Reinforcement, Before Concreting And Plastering Etc. Complete In All Respects.P.S No. 284 ( A ) . 21 Supply And Laying Of 25 Mm Dia Heavy Duty ( 2Mm Thick ) Pvc Conduit Complete With Bends And Other Acessories As Required And 14 Swg Fish Steel Wire Etc. In Slab Alongwith Reinforcement, Before Concreting And Plastering Etc. Complete In All Respects.P.S No. 282 ( A ) . 22 Supplying And Laying Of Aluminium Conductor Pvc Insulated Armoured, Served, Sheathed Cable 1100 Volts Grade At A Depth Of 750 Mm. Below Ground Level Over A Cushion Of 75 Mm. Thick Sand Alround And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respects. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. ( Grandlay, Skytone, Gloster, Kei, HavellS Make ) 23 ( 1 ) 4 Sq.Mm. X 4 Core ( Ps No. 501 ) 24 ( 2 ) 6 Sq.Mm. 4 Core ( Ps No. 501 ) 25 ( 3 ) 25 Sq.Mm. 3.5 Core ( Ps No. 501 ) 26 S / F Of Cable Lug ( Socket ) To The Cable Lead. Complete In All Respects As Per Ps No. 504 27 1- 4 Sq. Mm 28 2- 6 Sq. Mm 29 3- 16 Sq. Mm 30 4- 25 Sq.Mm. 31 S / Laying Of90 Mm Dia ( Od 90 Mm & Id 76 Mm Nominal ) Size Of ( Dwc ) Hdpe Pipes Isi Marked Along Wigh All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part-Ii Complete With Filling And Cutting, Jointing Etc. Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench Pat Excluding Sand Cushioning And Protective Covering Etc. Complete In All Respects. Rex / Duraline / Time / Cpe Make. As Per Dsr 2016 Item No. 14.16.2 Page No. 49 32 Supply And Fixing Of 40 Amp Tpncapacity Of Automatic Street Light Cubical Control Panel Painted With Anti Corrosive Alkali And Acid Proof Paint Crossing Of Time Switch Tso 100 Series With Contractors, Hrc Fuse, Isolating Swtich Metering Instrument & Instrument Box With Cts Etc. In Case Of Tpn, Complete In All Respects. As Per Ps No. 807F 33 Supply And Buring Of Safe Earthing Electrode T-19 ( Hot Dip Galvanized ) , Length Up To 2000Mm Outer Type 50Mm, Inner Pipe, 22Mm Terminal Dia 12Mm, Outer Gi Pipe Of 16 Swg And Inner Gi Pipe Of 12 Swg With Hot Dip Galvanization Up To 100 Micron Filled With Crystalline Conductive Mixture ( Ccm ) Having Anti Corrosive & Conductive Property With 50 Kgs Activated Soil ( Bfc ) Capable Of Reducing The Soil Resistivity With Good Micture Of Retaining Capicity Along With 30Cm Square C.I. Frame With Hinged Cover & Masonry Husing ( From Electrode Terminal To Switch Board, Cost Of 25X3 G.I. Strip Will Be Extra As Per Ps No. 725A 34 S / F Of 25X3 Mm. G.I. Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects As Per Direction Of E / I As P.S. No. 716

Key Value

Document Fees
INR 5310 /-
EMD
INR 390600.0 /-
Tender Value
INR 1.95 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail