Military Engineer Services-MES has published Tender For Maintenance Of Fire Fighting Equipments In The Area Of Age U Ws Ii Under Ge U Water Supply Delhi Cantt 10. Submission Date for this Tender is 28-03-2024. Fire Fighting Service Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42591360
Corrigendum : Tender For Maintenance Of Fire Fighting Equipments In The Area Of Age U Ws Ii Under Ge U Water Supply Delhi Cantt 10
Open Tender
Indian
Delhi
delhi
28-03-2024

Tender Details

Maintenance Of Fire Fighting Equipments In The Area Of Age U Ws Ii Under Ge U Water Supply Delhi Cantt 10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Mar-2024 Other Other 21-03-2024
2 21-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

Name of Work : MAINTENANCE OF FIRE FIGHTING EQUIPMENTS IN THE AREA OF AGE (U) WS-II UNDER GE(U) WATER SUPPLY,DELHI CANTT-10
Sl. No. Item Description
1Supply and fixing in replacement single headed Stainless Steel fire hydrant landing valve type "A" (single head outlet) of 80mm dia landing valve with 63mm dia female outlet complete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with couplings conforming to IS 903 including taking down the existing one complete all as specified and directed. (Note:- Old material of fire hydrant landing valve alongwith other accessiories shall be taken on charge under demolition/salvage egister in "EACH".)
2Supply and fixing in replacement of weather proof standard fire hose box made of 18 SWG gauge MS sheet 800mmx800 mmx250mm with double door with 4mm thick glasses and door frame including locking arrangement by allen key stove enamelled fire red finish with "Fire hose" marked on front and brilliant white inside yard suitable for housing of and consisting of 2 lenghts RRL hose pipe conforming to IS 636-1979 (type-II) of 63mm dia including taking down the existing onecomplete all as specified and as directed. (Note:- Old material offire hose box alongwith other accessiories shall be taken on charge under demolition/salvage egister in "EACH".)
3Supply and fixing in replacement in position 63mm nominal bore and 15mm long synthetic fibre circular woven jacketed rubberized fabric reinforced rubber lined (RRL) fire hose pipe of approved make bearing IS 636-1988 type A mark and heavy duty delivery hose coupling (conforming to IS ; 903) bound and rivetedto the hose pipe with copper rivets and copper wire complete all as specified and including taking down the existing one omplete all as specified and as directed. (Note:- Old material offire hose pipe alongwith other accessiories shall be taken on charge under demolition/salvage egister in "EACH".)
4Supply and fixing in replacement position Stainless steel 63mm dia short size branch pipes with 20mm dia nozzles with 63mm instantaneous coupling ISI marked (IS; 903) and including taking down the existing one complete all as specified directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of branch pipe in weight (EACH) shall be taken into account and attach with RAR/F Bill)
5Supply & fixing in replacement water delivery thermoplastic rubber line (first aid hose) as per IS 12585 20mm dia 30mtr length to with stand 10 Kg per sq cm working pressure fitted with gunmetal nozzle and shut off valve of any size complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of rubber line in weight (EACH) shall be taken into account and attach with RAR/F Bill)
6Supply & fixing Gun metal gate valve with iron wheel head screwed both iron iron pipe ISI Marked as per IS 778 of following sizes including taking out unserviceable gate valve complete all as specified and directed :-
725mm bore
850mm bore
9Supply, fixing, testing and commissioning of wall mounting swinging type first aid fire hose reel drum with drum size hanging bracket including thermoplastic rubber (first aid hose) as per IS 12585 20mm dia 30mtr lenght to with stand 10 Kg per sq cm working pressure fitted with gunmetal nozzle and shut off valve of any size complete all as specified the hose reel shall be conforming to IS 884-1985 including for 25mm dia MS pipe connection from riser to hose reel sockets nipples elbows valve etc Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete hook or MS stand as per site requirment, including taking down the existing one complete all as specified directed. (Note:- (i) Old material of fire hose reel drum alongwith other accessiories shall be taken on charge under demolition/salvage egister in "EACH".) (ii) Quated unit rate shall be included cost of fixing/hanging item of internal hydrant and one as either side of stage.
10Taking up and down from each floor and existing location for refilling of fire extinguisher of the following type size and capacity fixing existing/new location including PVC sleeve screw etc any requirement for fixing the extinguishers after refilling the extinguishers. (Note:- Testing report will be submited by contractor to the Engineer-in-Charge.)
11Fire extinguisher CO2type 4.5 Kg Capacity
12Fire extinguisher ABC powder type 5 Kg Capacity
13Supply, fixing, testing and commissioning of 300mm dia pipe heavy duty class "C" MS pipe ,ISI marked as per IS: 1239 with all necessary fittings and fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer including taking down the existing MS Pipe complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of MS Pipe in weight (RM) shall be taken into account and attach with RAR/F Bill)
14Supply & fixing in replacement Pad lock 40mm 7 LVR complete with 3 key complete all as specified and as directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of Pad lock in weight (EACH) shall be taken into account and attach with RAR/F Bill)
15Repair /Maintenace of Fire box such as replacement of broken hinges 2-4 Nos, making of locking arrangement including gas/ arc welding work complete and as required in site complete all as specified and as directed.
16Supply, fixing, jointing & testing cast Iron Sluice Valve ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body,Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed at site by the Engineer-in-Charge for following bore:- (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.) (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of sluice valve in weight (EACH) shall be taken into account and attach with RAR/F Bill)
1780mm bore
18150mm bore
19200mm bore
20250mm bore
21Supply, fixing, jointing and testing ofCast iron Non Return valve of size 80 mm dia without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.6 complete including taking out unserviceable NRV complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of item.) (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of NRV in weight (EACH) shall be taken into account and attach with RAR/F Bill)
22Supply, fixing, jointing & testing cast Iron Butterfly Valve of size 150mm dia ISI Marked,class (PN-1.0,) including taking out unserviceable Butterfly complete all as specified and directed at site by the Engineer-in-Charge. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.) (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of Butterfly valve in weight (EACH) shall be taken into account and attach with RAR/F Bill)
23Supply, fixing, jointing & testing in replacement of Bourdon type presure gauge with gun metal isolation cock and copper "U" Tube having calibration of 0-10 Kg/cum and 100mm dia size all as specified including taking out of unserviceable presure gauge complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of Bourdon type presure gauge in weight (EACH) shall be taken into account and attach with RAR/F Bill)
24Supply, fixing, jointing & testing in replacement of presure switches IPS 100 or approved equivalent including making connection with the control panel and the presure vessel complete in all respects the electric continuity is maintained between contacts NC and COM under normal conditions the contacts changeover to No & COM on rise of presure to preset valve all as including taking out of unserviceable presure switches complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of presure switches in weight (EACH) shall be taken into account and attach with RAR/F Bill)
25Supply, fixing, jointing & testing in replacement of gun metal Air release valve of size 25mm dia having rubber ball (of suitable range and calibrated complete screwed both ends for iron pipe including all accessary (nut bolt washers) ISI marked as per IS: 778 including taking out unserviceable bridge complete all as specified directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of Air release valve in weight (EACH) shall be taken into account and attach with RAR/F Bill)
26Supply, fixing, jointing & testing of Gun metal 3 way Fire brigade inlet to down commer line with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS: 904 with blank cap and chain existing one completeincluding all accessary (nut bolt washers) and including taking out unserviceable fire bridge complete all as specified directed. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of 3 way fire brigade in weight (EACH) shall be taken into account and attach with RAR/F Bill)
27M&L for applying one coat of synthetic enamelled paint as per approved colour code of fire fighting Riser pipe line (80mm to 150mm dia) in fire nitch ground floor to terrace pipe lines inside the the shaft and fire fighting station induction motor coupled with fire pump on terrace pump house etc complete all as specified directed
28Supply, fixing, jointing & testing in replacement of manual call point beark glass type enclosed in MS enclosures body of 3mm thickness complete with chain and hammer and Incl inscriber in case of fire break glass compete including all connected accessary and taking down the unserviceable manual call complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of manual call point beark glass in weight (EACH) shall be taken into account and attach with RAR/F Bill)
29Supply, fixing, jointing & testing in replacement of Electrically operated Electronic Hooter enclosed in MS enclosures of suitable size painted with sythetic enamaled paint red coloured complete with suitable transformer including all connected accessary and taking down the unserviceable hooter complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of Hooter in weight (EACH) shall be taken into account and attach with RAR/F Bill)
30Supply, fixing, jointing & testing and commissioning of 2x1.5sq. mm..+1x1.0sqmm earth wire 1100 voltes solid/multi stranded copper conductor PVC sheathed cable including suitable size of lugs for connection manual call point to Hooter including making good the surface of wall after replacement of conductor and taking down the unserviceable conductor complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of wire in weight (RM) shall be taken into account and attach with RAR/F Bill)
31M&L Alteration/ Modification in existing floor mounting type cylindrical pressure vessel add supporting legs size 150mm dia and 1.5 mtr high as per (IS;2062) and fixing testing and commissioning of the vessel including sockets/flanges welded for inlet outlet provision for pressure gauge, pressure switches, air release valve etc of sutiable required size. The pressure vessel shall be painted inside with anti-corrosive epoxy paint and outside with two or more coats of synthetic eneamel paint of fire red colour over a coat of ready mixed primer both of approved quality including taking down the existing vessel for alteration complete all as specified and as directed by Engr-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of pressure valve in weight (EACH) shall be taken into account and attach with RAR/F Bill)
32Supply, fixing, jointing & testing and commissioning of floor mouting type cylindrical pressure vessel with supporting legs size 150mm dia and 1.5Mtr high with dished end and knuckle radius (IS;2062) the vessel shall be made of 8mm thick MS plate welded alround with sockets/flanges welded for inlet outlet and scour pipes pressure gague, pressure switches, air release valve etc. of suitable required size the pressure vessel shall be painted inside with anti-corrosive epoxy paint and outside with two or more coats of synthetic enamel paint of fire red colour over a coat of ready mixed primer both of approved quality including taking down the unserviceable pressure vessel complete all as specified and as directed by EIC. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of vessel in weight (EACH) shall be taken into account and attach with RAR/F Bill)
33M&L for disconnection of electrical and water connection of the centrifugal puimp and motor of capacity 10 HP from base plate and transport to work shop, carfully opening and replacement of bushes, mechanical seal, ball bearing rubber gasket nut and bolt fixing the require new parts (parts such as shaft impeller, coupling, mechanical seal and bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making good all electrical and water connection and tesing complete all as specified. (Note : Rate including transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation and testing and commisioning.)
34Supply only shaft suitable for centrifugal pumps for 10 HP capacity
35Supply only GM impeller suitable for centrifugal pumps for 10 HP capacity
36Supply only MS Coupling suitable for centrifugal pumps for 10 HP capacity
37Supply only Bearing suitable for centrifugal pumps for 10 HP capacity
38Supply only Mechanical Seal for centrifugal pumps for 10 HP Capacity
39(Note for ser item No 26 to 31: Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of shaft, GM impeller, MS coupling, Bearing & mechanical seal in weight (EACH) shall be taken into account and attach with RAR/F Bill)
40Material and labour in replacement rewinding of electrical motor 10 HP super enameled copper winding wire of suitable size not less original after cutting and taking out old winding complete with all insulation material such as colton top vamish etc of centrifugal pump set motor complete all as specified and as directed. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of copper winding wire in weight (KG) shall be taken into account and attach with RAR/F Bill)
41Supplying, fixing, testing and commissioning of Main fire indicating panel with minimum ten number of Zones complete vise-versa, necessary controls LED indicators auxillary power supply test accept and reset push buttons local hooter and provision for passing on the panel battery back-up for 24 hours normal and 30 min alarm condition etc to be fixed in still floor with all connected necessary accessory including taking down the unserviceable fire panel complete all as specified and as directed. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (EACH SET) shall be taken into account and attach with RAR/F Bill)
42Supply and fixing in replacement Amp meter Digital type 0 to 100 Amp of size 96x96mm includingtaking down unserviceable amp meter complete all as specified and directed by Engr-in-Charge. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (EACH) shall be taken into account and attach with RAR/F Bill)
43Supply and fixing in replacement Voltmeter Digital type 0 to 500 Volts of size 96x96mm includingtaking down unserviceable Volt meter complete all as specified and directed by Engr-in-Charge. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (EACH) shall be taken into account and attach with RAR/F Bill)
44Supply and fixing in replacement of indicating light RYB LED type includingtaking down unserviceable RYB light complete all as specified and directed by Engr-in-Charge. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (EACH) shall be taken into account and attach with RAR/F Bill)
45Supply and fix MCCB 63 Amp 4 pole 415 volts 50 HZ 10 KA includingtaking down unserviceable MCCB complete all as specified and directed by Engr-in-Charge. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (EACH) shall be taken into account and attach with RAR/F Bill)
46Supply and fix MCCB 32 Amp Three pole 415 volts 50 HZ 10 KA includingtaking down unserviceable MCCB complete all as specified and directed by Engr-in-Charge. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (EACH) shall be taken into account and attach with RAR/F Bill)
47Supply and fix MCB 6/32 Amp Single Pole 230 volts 50 HZ 10 KA includingtaking down unserviceable MCCB complete all as specified and directed by Engineer-in-Charge. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (EACH) shall be taken into account and attach with RAR/F Bill)
48M&L for erthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with topedge of the plate not less then 1.5 meter below ground level connected to galvanised iron dtrip 25x4 mm as earthing lead with 40mm dia light grade protection pipe for GI strip by means of bolts nuts, check nuts and washer of galvanised from of steel as shown in electrical plateNo 3 connected to earthing test point including taking down unserviceable earthing set all as specified and directed. Note ; GI strip 32x4 mm beynod 7.5 mtr shall be measured and seperately necessary excavation and earth work in any type of soll and PCC 1:3:6 type c1 for earthing chember 40mm thick RCC even 1:2:4 type B1 with 6mm dia TMT bars at 140mm C/C both ways wanting pipe 20mm dia light grade GI funnel wire mesh lugs charcoal and comman sall etc complete all as specified and directed by Engr-in-Charge
49S&F of Aluminum iron strip 25x4mm as earthing lead including connecting to earth test point to the equipment to be earthed by means of nut, bolt and washers including taking down unserviceable and broken iron strip complete all as specified and directed
50Supply laying connectioin and testing LT XLPE screened insulated armoured havey duty 1100 volts grade sheeted 10 sq mm 4 cores stranded aluminium conductor including connection to panel at incoming and out going using suitable aluminium lugs and Fixing to walls and floors with necessary clamp/accessariesincluding taking down unserviceable cablecomplete all as specified and directed by Engineer-in-Charge. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of LT Cable in weight (RM) shall be taken into account and attach with RAR/F Bill)
51M&L Construction of valves pit chamber in replacement having internal dimension 120mm x 120mm x 120 mm (internal height) using PCC (1:4:8)40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thickwall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm thick MS top sheet cover with locking arrangement including 50 mmpad lock with double key angle iron includingpainting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and as directed by the Engineer-in-Charge. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of brick work and steel in weight (CUM) shall be taken into account and attach with RAR/F Bill)
52Supply and fixing &installation in replacement ofperforated MS cable tray of size 350x50x2mm including horizontal and vertical bends, prepared hanging systemand other accessories including painting of cable tray of complete all as specified and directed. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of Cable tray in weight (RM) shall be taken into account and attach with RAR/F Bill)
53M&L MS works of any sizes of angles irons/flat iron/MS sheet works for making Grills, Gates, Covers and Stair steps etc including fabrication complete all as specified and as directed. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of MS work in weight (KG) shall be taken into account and attach with RAR/F Bill)
54Supply & fixing in replacement install testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, Aluminium bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , Powder Coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron , minimum 1 feet long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc .
55Aluminium bus bar with PVC sleeve rating 100 Amps for Phase & 100 Amp for neutral- 01Set.
56Voltmeter,digital type 0- 500 volt,with selector switch - 01 set
57Ammeter Digital type 0-100Amps, with selector switch and CT -1 Set
58Phase indicating lamps LED type ( RYB) 01 Set
59Incoming MCCB 63 Amp 3 pole 10 kA with adjustable thermal and fixed magnetic release -01 No
60Outgoing MCCB32 Amp 3-Pole 10 kA with adjustable thermal & fixed magnetic release - 01 Nos
61Outgoing MCB SPN 16A, 10kA - 01 Nos
62FASD Stater MN-16 FASD-01 Nos
63Analog time switch -01 No
64Single phase preventer-01 No
65Note :- (i) LT panel drawing shall be got approved by GE. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of LT Panel in weight (KG) shall be taken into account and attach with RAR/F Bill) (iii) Contractor will be submit drawing of approved make to EIC for approval of GE).
66M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
67M&L Brick work in CM (1:4) with sub class "B" bricks above ground level and not exceeeding 1.5mtr in height from ground level including demolition of brick work complete all as specified and as directed.
68M&L Rendering 10 mm thick plaster on brick work/concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and as directed.
69Servicing of Single headed Gun Metal fire hydrant landing valve type A (single head outlet)of 80mm dia landing valve with 63mm dia female outlet complete and Lugs, GM nut,Coupling complete all as specified and as directed by the Engineer-in-Charge. (Note :-Any spare parts if required deemed to be quoted rates.)
70M&L for Writing letters or figures on FHC (Black, Roman, Italic or Indian) with paint not exc 30cm height and 10cm width complete all as specified and as directed by the Engineer-in-Charge.
71Excavation in trenches not exc 1.5 metres wide and not exc1.5 metres deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required level complete all as specified and as directed.
72Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
73Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and as directed.
74Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines includingPCC (1:2:4) type B-2(with 40 mm graded aggregate) in foundations,filling and mass concrete complete including making good the existing surface complete all as specified and as directed.
75Taking up old CI/DI/MS Pipes including all fitting of 150 mm dia complete all as specified and directed.
76All as per Item No. 56 here-in-above but of size 100 mm dia. (Note for ser item No 56 and 57 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (RM) shall be taken into account and attach with RAR/F Bill)
77Supply, layingjointing,testingDIpipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches for following dia complete all as specified and directed by Engineer-in-Charge. (Note:Tyton Joint, Excavation & earth work shall be measured & paid separetely)
78100mm bore
79150mm bore
80Note :- (a) Layout plan for laying of DI pipe shall be given by EIC in writing. (b) DI pipe whole quantity of tender shall be procured by contractor for payment in 1st RAR as material lying at site. (c) Piece meal site laying shall be given by EIC and contractor transport the DI pipe accordingly. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.
81Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y" junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore including taking out old pipe complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
82Material and labour for Rubber Gasket Joint (Tyton Joint) including jointingmaterial for DI/CI pipe of 150 mm dia complete all as specified and directed by Engr-in-Charge.
83All as per Item No. 61 here-in-above but of size 100 mm dia.
84Boring of holes under road pavement by bocky manually in any type of soil up to 250mm bore complete all as specified and as directed .
85Fixing only in replacement of MS Pipes heavy grade with all fittings such as bend, elbow,Tee, reducer etc laid in floors or fixed to walls upto 9 story Bldg and ceilings including welding, flange, fixing of pipe incl gasket, nut, bolt washer etc with necessary standard clamps structural steel support, cutting as required at site site including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer including taking down the existing one complete all as specified and directed by Engr-in-Charge.(Note : MS Pipe shall be issued from AGE E/M WS No-II Store yard. under ch "B" stores)
86200 mm
87150 mm
88100 mm
8980 mm
9025 mm
91Supply & Fixing in replacement 4 mm plain glass along with Rubber Beading etc change in FHC complete all as specified and as directed.
92Supply & fixing/ hanging , testingof wall mounting swinging type First aid firehose reel with drum, hanging bracket,for 25 mm dia MS pipe connection from riser to hose reel sockets,nipples,elbows,valve etc. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete hook or MS stand as per site requirement including taking down of existing complete all as specified and as directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of swinging type first aid fire hose reel in weight (KG) shall be taken into account and attach with RAR/F Bill)