Rate Contract Of Cardic Items Contract Of Cardic Items , Rate Contract Ofcardiac Items , Radial Sheathwith Puncture Needle For Adults • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two ( Thinner ) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21’’ Guide Wire Compatible • Diameter: 4, 5, 6, & 7 Fr • Lengths: 11 Cm ( 23 Cm In 6 Fr ) • With 21G Needle • Usfda / Pmda Approved , Radial Sheathwith Puncture Needle For Adults • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two ( Thinner ) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21’’ Guide Wire Compatible • Diameter: 4, 5, 6, & 7 Fr • Lengths: 11 Cm ( 23 Cm In 6 Fr ) • With 21G Needle • Ce - Approved , Radial Sheathwith Puncture Needle For Pediatric Patients • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two ( Thinner ) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21’’ Guide Wire Compatible • Diameter: 4, 5, & 6 Fr • Lengths: 7.5 Cm • Usfda / Pmda Approved , Radial Sheathwith Puncture Needle For Pediatric Patients • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two ( Thinner ) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21’’ Guide Wire Compatible • Diameter: 4, 5, & 6 Fr • Lengths: 7.5 Cm • Ce - Approved , Femoral Sheathwith Puncture Needle For Adults • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two ( Thinner ) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.38’’ Guide Wire Compatible • Diameter: 4, 5, 6, 7, 8, 9, 10 & 11 Fr • Lengths: 11 Cm • Usfda / Pmda Approved , Femoral Sheathwith Puncture Needle For Adults • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two ( Thinner ) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.38’’ Guide Wire Compatible • Diameter: 4, 5, 6, 7, 8, 9, 10 & 11 Fr • Lengths: 11 Cm • Ce Approved , Femoral Sheathwith Puncture Needle For Adults –Mid Length • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two ( Thinner ) Layers Of Polyethylene • Color Codes For Easy French Size Identification • Diameter: 6, 7, & 8 Fr • Lengths: 23 Cm • With Usable Dilator 30 Cm • Usfda / Pmda Approved , Femoral Sheathwith Puncture Needle For Adults –Mid Length • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two ( Thinner ) Layers Of Polyethylene • Color Codes For Easy French Size Identification • Diameter: 6, 7, & 8 Fr • Lengths: 23 Cm • With Usable Dilator 30 Cm • Ce- Approved , Braided Long Sheath- • Atraumatic Tip For Carotid & Distal Procedures • Haemostatic Valves ( Cross Cut Valve & Tbv- Detachable Valves For Thrombus Management ) • Gold Coil Marker - For Distal Visibility Ptfe Coating - Seamless Device Transition • Distal Hydrophilic Coated For Navigability • Nylon Outer Layer With Reinforced Stainless-Steel Coil • Available In Diameter 6, 7, 8 Fr. And Length 45Cm, 65Cm & 9Ocm. • Usfda / Pmda- Approved , Braided Long Sheath- • Atraumatic Tip For Carotid & Distal Procedures • Haemostatic Valves ( Cross Cut Valve & Tbv- Detachable Valves For Thrombus Management ) • Gold Coil Marker - For Distal Visibility Ptfe Coating - Seamless Device Transition • Distal Hydrophilic Coated For Navigability • Nylon Outer Layer With Reinforced Stainless-Steel Coil • Available In Diameter 6, 7, 8 Fr. And Length 45Cm, 65Cm & 9Ocm. • Ce- Approved , Support Catheter •Double Braided Stainless-Steel Shaft With 0.035 • Guidewire With One Embedded Two Swaged Radiopaque Markers. • Usfda / Pmda Approved , Support Catheter • Double Braided Stainless-Steel Shaft With 0.035 • Guidewire With One Embedded Two Swaged Radiopaque Markers. • Ce- Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Must Have 32 Standards Of Stainless Steel Braid • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) • Transradial Catheter Shapes-Tig, Tig Ii, Jacky, Sarah. 4Fr.-5Fr.-6Fr. Largest Inner Diameter Should Be Of 4 Fr=1.03Mm 5 Fr=1.20 Mm 6 Fr=1.30 Mm • Usfda / Pmda Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Must Have 32 Standards Of Stainless Steel Braid • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) • Transradial Catheter Shapes-Tig, Tig Ii, Jacky, Sarah. 4Fr.-5Fr.-6Fr. Largest Inner Diameter Should Be Of 4 Fr=1.03Mm 5 Fr=1.20 Mm 6 Fr=1.30 Mm • Ce -Approved , Special Guiding Catheter – • Must Have Ikari Curve For Radial Route. • High Strength Wired Braided Catheter With Inner Layer Of Ptfe •Fuoro Polymer To Facilitates Smoother Delivery, Provides Robust Backup. • Must Have Zone Technology-Five Zone Each Fabricated From A Material Of Different Stiffness, To Provide Optimum Engagement And Backup Support And Soft And Atraumatic Tip. • Must Have Larger Lumen. 6Fr Id .071 • Shape 3-5, Size- 4Fr To 8 Fr • Should Be Available With Short & Long Tip For Each Curve • Must Have Al, Ar, Jl, Jr, Extra Back Up, Internal Mammary, Multipurpose, Straight, Tiger Curve, Voda • Usfda / Pmda Approved , Special Guiding Catheter – • Must Have Ikari Curve For Radial Route. • High Strength Wired Braided Catheter With Inner Layer Of Ptfe •Fuoro Polymer To Facilitates Smoother Delivery, Provides Robust Backup. • Must Have Zone Technology-Five Zone Each Fabricated From A Material Of Different Stiffness, To Provide Optimum Engagement And Backup Support And Soft And Atraumatic Tip. • Must Have Larger Lumen. 6Fr Id .071 • Shape 3-5, Size- 4Fr To 8 Fr • Should Be Available With Short & Long Tip For Each Curve • Must Have Al, Ar, Jl, Jr, Extra Back Up, Internal Mammary, Multipurpose, Straight, Tiger Curve, Voda • Ce- Approved , Coronary Micro-Guide Catheter – Distal 70 Cm Hydrophilic Coat. • Must Have Tapered Stainless Steel Braid Mesh Construction And Inner Ptfe Layer. • Must Have 13 Cm Floppy Distal Segment. • Must Have Distal Outer Diameter 1.8 Fr Or Less And Proximal Outer Diameter 2.6Fr. • Must Have 70Cm Distal Hydrophilic Coating. • Must Be Available In Catheter Length 130Cm For Antegrade Approach And 150 Cm For Retrograde Approach. • Must Have Gold Marker For The Tip Visibility • Usfda / Pmda Approved , Coronary Micro-Guide Catheter – Distal 70 Cm Hydrophilic Coat. • Must Have Tapered Stainless Steel Braid Mesh Construction And Inner Ptfe Layer. • Must Have 13 Cm Floppy Distal Segment. • Must Have Distal Outer Diameter 1.8 Fr Or Less And Proximal Outer Diameter 2.6Fr. • Must Have 70Cm Distal Hydrophilic Coating. • Must Be Available In Catheter Length 130Cm For Antegrade Approach And 150 Cm For Retrograde Approach. • Must Have Gold Marker For The Tip Visibility • Ce Approved , Aspiration Thrombectomy Catheter • Available In Size 6F, 7F Both, Must Have Entry Profile 0.019 Inches • Must Have 1.30 Mm Square Suction Area • Braided Polyamide Elastomer Shaft, Stainless Steel Wire Braiding And Guide Wire Type Stylet, • 6.0Mm Tip Length For Making Aspiration Inlet To Come Closer To The Target Thrombus And 10Cm-Length Depth. • Must Have Distal 40 Cm Hydrophilic Coating. • Usfda / Pmda Approved , Aspiration Thrombectomy Catheter • Available In Size 6F, 7F Both, Must Have Entry Profile 0.019 Inches • Must Have 1.30 Mm Square Suction Area • Braided Polyamide Elastomer Shaft, Stainless Steel Wire Braiding And Guide Wire Type Stylet, • 6.0Mm Tip Length For Making Aspiration Inlet To Come Closer To The Target Thrombus And 10Cm-Length Depth. • Must Have Distal 40 Cm Hydrophilic Coating. • Ce Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21, 25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter – Judkin Left And Right, ( Jl3-Jl5, Jr3-Jr5 ) Amplatz Left & Right, ( Al1 & 2, Ar 1 & 2 ) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr., 7 Fr. • Usfda / Pmda Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21, 25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter – Judkin Left And Right, ( Jl3-Jl5, Jr3-Jr5 ) Amplatz Left & Right, ( Al1 & 2, Ar 1 & 2 ) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr., 7 Fr. • Ce - Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 40 Cm To 260 Cm Of Length And .018” To .038” Diameter • With Silicon Coated Tip And Bevel Indicator • Usfda / Pmda Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 40 Cm To 260 Cm Of Length And .018” To .038” Diameter • With Silicon Coated Tip And Bevel Indicator • Ce- Approved , Hydrophilic Guidewire ( Regular Length ) With Mcoat Technology Tapered Tip, Single Nitinol Core Alloy, Tungsten-Infused Polyurethane Jacket • Hydrophilic Polymer Coat. One Piece Construction & Radiopaque Polyurethane Jacket. • Must Be Available In Standard And Stiff. • Must Be Available In .035, .032, .038, .025. .018 Diameter & 150 Cm, 180 Cm Length - Straight / Angled / 1.5Mm J Shape • Usfda / Pmda Approved , Hydrophilic Guidewire ( Regular Length ) With Mcoat Technology Tapered Tip, Single Nitinol Core Alloy, Tungsten-Infused Polyurethane Jacket • Hydrophilic Polymer Coat. One Piece Construction & Radiopaque Polyurethane Jacket. • Must Be Available In Standard And Stiff. • Must Be Available In .035, .032, .038, .025. .018 Diameter & 150 Cm, 180 Cm Length - Straight / Angled / 1.5Mm J Shape • Ce Approved , Hydrophilic Guidewire ( Exchange Length ) With Mcoat Technology Tapered Tip, Single Nitinol Core Alloy, Tungsten-Infused Polyurethane Jacket • Hydrophilic Polymer Coat. One Piece Construction & Radiopaque Polyurethane Jacket. • Must Be Available In Standard And Stiff. • Must Be Available In .035, .032, .038, .025, .018 Diameter And 260 & 300 Cm Length - Straight / Angled / 1.5Mm J Shape • Usfda / Pmda Approved , Hydrophilic Guidewire ( Exchange Length ) With Mcoat Technology Tapered Tip, Single Nitinol Core Alloy, Tungsten-Infused Polyurethane Jacket • Hydrophilic Polymer Coat. One Piece Construction & Radiopaque Polyurethane Jacket. • Must Be Available In Standard And Stiff. • Must Be Available In .035, .032, .038, .025, .018 Diameter And 260 & 300 Cm Length - Straight / Angled / 1.5Mm J Shape • Ce Approved , Ptfe Guidewire ( Regular Length ) • Silicon Coated Tip With Choice Of Stainless-Steel Core Or Nitinol Core, • 150Cm, 175 Cm Of Lengths & 0.018 To 0.038 Diameter With Silicon Coated Tip. • Usfda / Pmda Approved , Ptfe Guidewire ( Regular Length ) • Silicon Coated Tip With Choice Of Stainless-Steel Core Or Nitinol Core, • 150Cm, 175 Cm Of Lengths & 0.018 To 0.038 Diameter With Silicon Coated Tip. • Ce Approved , Ptfe Guidewire – 260 Cm ( Exchange Length ) • Silicon Coated Tip With Choice Of Stainless-Steel Core Or Nitinol Core, • 150Cm, 175 Cm Of Lengths & 0.018 To 0.038 Diameter With Silicon Coated Tip. • Usfda Approved , Ptfe Guidewire – 260 Cm ( Exchange Length ) • Silicon Coated Tip With Choice Of Stainless-Steel Core Or Nitinol Core, • 150Cm, 175 Cm Of Lengths & 0.018 To 0.038 Diameter With Silicon Coated Tip. • Ce Approved , Special Angiography Wire For Radial Artery Anomalies • 1.5Mm J Tip • Diameter Of 1.9 Mm To 2.3 Mm • Elastic Nitinol Core • M Coat Hydrophilic Material Coating • 1 Piece Construction For One-To-One Torque • Radio Opaque Polyurethane Jacket • Tungsten Mix For High Visibility In X-Ray • Usfda / Pmda- Approved , Special Angiography Wire For Radial Artery Anomalies • 1.5Mm J Tip • Diameter Of 1.9 Mm To 2.3 Mm • Elastic Nitinol Core • M Coat Hydrophilic Material Coating • 1 Piece Construction For One-To-One Torque • Radio Opaque Polyurethane Jacket • Tungsten Mix For High Visibility In X-Ray • Ce- Approved , Baby J Wire With 1.5Mm J Tip – 260 Cm • Baby J Curve Must Have Radius Of 1.5 Mm. • Super Elastic Nitinol Alloy, M Coat Hydrophilic Coat, • One Piece Construction For 1:1 Torque & Radiopaque Polyurethane Jacket. • Must Have Tungsten-Infused Polyurethane Jacket. • Usfda / Pmda Approved , Baby J Wire With 1.5Mm J Tip – 260 Cm • Baby J Curve Must Have Radius Of 1.5 Mm. • Super Elastic Nitinol Alloy, M Coat Hydrophilic Coat, • One Piece Construction For 1:1 Torque & Radiopaque Polyurethane Jacket. • Must Have Tungsten-Infused Polyurethane Jacket. • Ce Approved , High Pressure Semi-Compliant Ptca Balloon. • Must Have Low Entry Tip Profile < 0.016”. • Should Have Nominal Pressure 6Atm Or Above And Rbp Above 14Atm. • Balloon Must Have P-Tech Coating & Stainless Steel Hypotube For Kink Resistant & Superior Deliverability. • Diameter1-5 Mm • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Usfda / Pmda Approved. , High Pressure Semi-Compliant Ptca Balloon. • Must Have Low Entry Tip Profile < 0.016”. • Should Have Nominal Pressure 6Atm Or Above And Rbp Above 14Atm. •Balloon Must Have P-Tech Coating & Stainless Steel Hypotube For Kink Resistant & Superior Deliverability. • Diameter1-5 Mm • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Ce- Approved. , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Usfda / Pmda Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Ce-Approved , Special Ptca Balloon ( Non-Compliant ) . • Entry Profile <0.016”, • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Usfda / Pmda Approved , Special Ptca Balloon ( Non-Compliant ) . • Entry Profile <0.016”, • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Ce Approved , Special Ptca Balloon For Cto • Starting Diameter 0.85Mm With Rbp 16 Atm Or Above. • Low Entry Tip Profile < 0.015”. • Balloon Hypotube Must Be Stainless Steel Along With Having Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. • Should Have Extended Guide Wire Lumen 30Cm For Better Pushability In The Cto Lesions. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. •Usfda / Pmda-Approved. , Special Ptca Balloon For Cto • Starting Diameter 0.85Mm With Rbp 16 Atm Or Above. • Low Entry Tip Profile < 0.015”. • Balloon Hypotube Must Be Stainless Steel Along With Having Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. • Should Have Extended Guide Wire Lumen 30Cm For Better Pushability In The Cto Lesions. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. •Ce-Approved. , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. • Must Have Diameter Starting From 1.75Mm-5.0Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Distal Tip Must Be Z-Tip For Zero Transition With Conventional Steerable Guidewires. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Usfda / Pmda Approved. , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. • Must Have Diameter Starting From 1.75Mm-5.0Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Distal Tip Must Be Z-Tip For Zero Transition With Conventional Steerable Guidewires. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Ce- Approved. , High Pressure ( Non-Compliant ) Ptca Balloon • Entry Profile <0.016”, • Made Up Of Dual Layer Of Nylon & Pebax Material For Controlled Expansion & Apposition. • Balloon Must Available In Longest Length Of 22Mm & 26Mm. • Should Have High Rbp Of 24 Atm. Available From Smallest Diameter 1.5Mm-5.0Mm. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Us Fda / Pmda Approved. , High Pressure ( Non-Compliant ) Ptca Balloon • Entry Profile <0.016”, • Made Up Of Dual Layer Of Nylon & Pebax Material For Controlled Expansion & Apposition. • Balloon Must Available In Longest Length Of 22Mm & 26Mm. • Should Have High Rbp Of 24 Atm. Available From Smallest Diameter 1.5Mm-5.0Mm. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Ce- Approved. , Wire Based Scoring Balloon Dilation Catheter On Non-Compliant Platform. • Entry Profile <0.016”, • Must Having High Rbp Of 20 Atm. • Available From Smallest Diameter 1.75Mm Onwards. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Usfda / Pmda- Approved. , Wire Based Scoring Balloon Dilation Catheter On Non-Compliant Platform. • Entry Profile <0.016”, • Must Having High Rbp Of 20 Atm. • Available From Smallest Diameter 1.75Mm Onwards. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Ce- Approved. , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Usfda / Pmda Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Ce - Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Usfda / Pmda Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Ce – Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Usfda / Pmda Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Ce - Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Usfda / Pmda Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Ce - Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Usfda / Pmda Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Ce - Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Usfda / Pmda Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Ce - Approved , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Usfda / Pmda Approve , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Ce Approved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Usfda / Pmdaapproved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Ce Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Usfda / Pmda Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Ce Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Usfda / Pmda Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Ce Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Usfda / Pmda Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Ce Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Usfda / Pmda Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Ce Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6 To30 • Diameter ( Mm ) : 2 To5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Usfda / Pmda Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6 To 30 • Diameter ( Mm ) : 2 To 5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Ce Approved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved. , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Usfda / Pmdaapproved , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Ce - Approved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Usfda / Pmdaapproved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Ce- Approved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimumvisualization •With Tfe Coating , 180 Cm To 300Cm • Usfda / Pmdaapproved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimumvisualization • With Tfe Coating , 180 Cm To 300Cm • Ce - Approved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long • Usfda / Pmdaapproved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long • Ce – Approved , Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length Ptca Wire • Must Have Platinum Coil At Distal Tip. • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Should Have M Coat Hydrophilic Coating Up To 248 Mm • Wire Should Have Ptfe Coating From 25 To 180 Cm Length. • Should Be Available In 0.6 Gf, 1Gf & 3.6Gf Tip Loads • Should Be Available In Floppy Tip, Extra Floppy Tip, Hypercoat Tip & Intermediate Tip . • Usfda / Pmda Approved , Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length Ptca Wire • Must Have Platinum Coil At Distal Tip. • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Should Have M Coat Hydrophilic Coating Up To 248 Mm • Wire Should Have Ptfe Coating From 25 To 180 Cm Length. • Should Be Available In 0.6 Gf, 1Gf & 3.6Gf Tip Loads • Should Be Available In Floppy Tip, Extra Floppy Tip, Hypercoat Tip & Intermediate Tip . • Ce Approved , Extra Floppy Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 / 300 Cm Length • Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Must Have Ptfe Coating From 25 To 180 Cm Length. & Mucus Coat Hydrophilic Coating Up To 248 Mm • Should Have 0.6-Gram Force Tip Loads • Usfda / Pmda Approved , Extra Floppy Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 / 300 Cm Length • Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Must Have Ptfe Coating From 25 To 180 Cm Length. & Mucus Coat Hydrophilic Coating Up To 248 Mm • Should Have 0.6-Gram Force Tip Loads • Ce Approved , Floppy Tip Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length. • Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Must Have M Coat Hydrophilic Coating Up To 248 Mm, & Ptfe Coating From 25 To 180 Cm Length. • Should Have 1 Gram Force Tip Loads • Usfda / Pmda Approved , Floppy Tip Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length. • Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Must Have M Coat Hydrophilic Coating Up To 248 Mm, & Ptfe Coating From 25 To 180 Cm Length. • Should Have 1 Gram Force Tip Loads • Ce Approved , Hypercoat Ptca Guide Wire With 9.7-Gram Force Rail Support– Mucus Coated Hydrophilic Distal Tip, 0.014” Diameter And 180 / 300 Cm Length • Must Have Platinum Coil At Distal Tip. 14 Mm Tip Shape Length. • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Must Have M Coat Hydrophilic Coating Up To 250 Mm & Ptfe Coating From 25 To 180 Cm Length. • Should Have 1-Gram Fore Tip Load • Usfda / Pmda Approved , Hypercoat Ptca Guide Wire With 9.7-Gram Force Rail Support– Mucus Coated Hydrophilic Distal Tip, 0.014” Diameter And 180 / 300 Cm Length • Must Have Platinum Coil At Distal Tip. 14 Mm Tip Shape Length. • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Must Have M Coat Hydrophilic Coating Up To 250 Mm & Ptfe Coating From 25 To 180 Cm Length. • Should Have 1-Gram Fore Tip Load • Ce Approved , Cto Stiff Ptca Guide Wire - 3.6-Gram Force Tip Load – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length. • Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Must Have M Coat Hydrophilic Coating Up To 248 Mm & Ptfe Coating From 25 To 180 Cm Length. • Should Have 3.6-Gram Fore Tip Load • Usfda / Pmda Approved , Cto Stiff Ptca Guide Wire - 3.6-Gram Force Tip Load – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length. • Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating • Must Have Directly Jointed Sus And Nitinol Shaft Through Duocore Technology And Silicon Coated Joint. • Must Have M Coat Hydrophilic Coating Up To 248 Mm & Ptfe Coating From 25 To 180 Cm Length. • Should Have 3.6-Gram Fore Tip Load • Ce Approved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Usfda / Pmdaapproved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Ce – Approved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Usfda / Pmdaapproved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Ce - Approved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Usfda / Pmdaapproved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Ce - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Ce - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Ce - Approved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Usfda / Pmdaapproved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Ce - Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Usfda / Pmdaapproved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Ce - Approved , Guidewire Gt-Angioplasty •0.012, 0.014 , 0.016 & 0.018 • Guidewire With Outstanding Torque Control, • Extremely Flexible Excellent Visibility • Available In Tip Angle Of 45, 90 And Double Angle 90+150. • Usfda / Pmda Approved , Guidewire Gt-Angioplasty •0.012, 0.014 , 0.016”& 0.018 • Guidewire With Outstanding Torque Control, • Extremely Flexible Excellent Visibility • Available In Tip Angle Of 45, 90 And Double Angle 90+150. • Ce- Approved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Usfda / Pmdaapproved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Ce - Approved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Usfda / Pmdaapproved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Ce- Approved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Usfda / Pmdaapproved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Ce - Approved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Usfda / Pmdaapproved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Ce - Approved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Usfda / Pmdaapproved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Ce - Approved , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Usfda / Pmdaapproved Wire Lengths-190 Cm & 300 Cm , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Ce-Approved Wire Lengths-190 Cm & 300 Cm , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Usfda / Pmdaapproved , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Ce- Approved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Usfda / Pmdaapproved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Ce- Approved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Usfda / Pmdaapproved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Ce - Approved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Usfda / Pmdaapproved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Ce- Approved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Usfda / Pmdaapproved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Ce - Approved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Usfda / Pmdaapproved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Ce - Approved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size Usfda / Pmdaapproved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size • Ce- Approved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Usfda / Pmdaapproved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Ce - Approved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Usfda / Pmdaapproved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Ce - Approved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Usfda / Pmdaapproved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Ce - Approved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Usfda / Pmdaapproved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Ce - Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Usfda / Pmdaapproved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Ce Approved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Usfda / Pmdaapproved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Ce- Approved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Usfda / Pmdaapproved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Ce - Approved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Usfda / Pmdaapproved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Ce - Approved , Asd Closure Devices Without Delivery System • Usfda / Pmdaapproved , Asd Closure Devices Without Delivery System • Ce - Approved , Asd Closure Devices Without Delivery System • Dcgi - Approved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Usfda / Pmdaapproved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Ce- Approved , Asd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Usfda / Pmdaapproved , Asd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Ce - Approved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Usfda / Pmdaapproved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Ce - Approved , Left Atrial Appendage Closure Device • Usfda / Pmdaapproved , Left Atrial Appendage Closure Device • Ce - Approved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Usfda / Pmdaapproved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Ce - Approved , Pfo Closure Devices Without Delivery System – • Usfda / Pmdaapproved , Pfo Closure Devices Without Delivery System – • Ce- Approved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Usfda / Pmdaapproved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Ce - Approved , Sizing Balloon For Device Closure – Circular Shape • Usfda / Pmdaapproved , Sizing Balloon For Device Closure – Circular Shape • Ce - Approved , Sizing Balloon For Device Closure – Oval Shaped • Usfda / Pmdaapproved , Sizing Balloon For Device Closure – Oval Shaped • Ce- Approved , Sizing Plate For Device Closure – • Usfda / Pmdaapproved , Sizing Plate For Device Closure – • Ce -Approved , Delivery Cable For Asd / Vsd / Pda Devices – • Usfda / Pmdaapproved , Delivery Cable For Asd / Vsd / Pda Devices – • Ce- Approved , Retrievers For Asd / Vsd / Pda Devices – • Usfda / Pmdaapproved , Retrievers For Asd / Vsd / Pda Devices – • Ce- Approved , Sheath For Retrival Of Devices – • Usfda / Pmdaapproved , Sheath For Retrival Of Devices – • Ce- Approved , Amplatzer Plug- • Usfda / Pmdaapproved , Amplatzer Plug- • Ce- Approved , Left Atrial Apendage Closure Device- • Usfda / Pmdaapproved , Left Atrial Apendage Closure Device- • Ce- Approved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Usfda / Pmdaapproved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Ce-Approved , Vsd Closure Devices Without Delivery System – • Usfda / Pmdaapproved , Vsd Closure Devices Without Delivery System – • Ce-Approved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Usfda / Pmdaapproved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Ce-Approved , Vsd Closure Device With Delivery System :-Elongatable Waist Soft Woven Meshlow Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Usfda / Pmdaapproved , Vsd Closure Device With Delivery System :-Elongatable Waist Soft Woven Meshlow Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Ce-Approved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Usfda / Pmdaapproved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Ce-Approved , Pda Closure Devices Without Delivery System • Usfda / Pmdaapproved , Pda Closure Devices Without Delivery System • Ce-Approved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Usfda / Pmdaapproved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Ce-Approved , Pda Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Usfda / Pmdaapproved , Pda Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Ce-Approved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Usfda / Pmdaapproved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Ce-Approved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Usfda / Pmdaapproved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Ce-Approved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Usfda / Pmdaapproved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Ceapproved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Usfda / Pmdaapproved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Ce-Approved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Usfda / Pmdaapproved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Ce-Approved , Pediatricfemoral Sheath 4 Fr. • Usfda / Pmdaapproved , Pediatricfemoral Sheath 4 Fr. • Ce-Approved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Usfda / Pmdaapproved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Ce-Approved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Usfda / Pmdaapproved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Ce-Approved , Mullin Sheath With Dilator • Usfda / Pmdaapproved , Mullin Sheath With Dilator • Ce-Approved , Trans- Septal Needle. • Usfda / Pmdaapproved , Trans- Septal Needle. • Ce-Approved , Ptmc Balloon With All Accessories ( Mullin Sheath, Coiled Wire Dilator, Stylet Trans-Septal Needle ) • *Specially Designed Balloon, Perfectly Shaped To For The Mitral Valve • *Short Inflation / Deflation Cycle • *New Small And Soft Tip • *Large Size Matrix • *Longer Guide Wire To Increase Safety In Taller Patients • Usfda / Pmda Approved , Ptmc Balloon With All Accessories ( Mullin Sheath, Coiled Wire Dilator, Stylet Trans-Septal Needle ) • *Specially Designed Balloon, Perfectly Shaped To For The Mitral Valve • *Short Inflation / Deflation Cycle • *New Small And Soft Tip • *Large Size Matrix • *Longer Guide Wire To Increase Safety In Taller Patients • Ce- Approved , Ptmc Balloon - • *Specially Designed Balloon, Perfectly Shaped To For The Mitral Valve • *Short Inflation / Deflation Cycle • *New Small And Soft Tip • *Large Size Matrix • *Longer Guide Wire To Increase Safety In Taller Patients • Usfda / Pmda Approved , Ptmc Balloon - • *Specially Designed Balloon, Perfectly Shaped To For The Mitral Valve • *Short Inflation / Deflation Cycle • *New Small And Soft Tip • *Large Size Matrix • *Longer Guide Wire To Increase Safety In Taller Patients • Ce- Approved , Brs Stent • Scaffold Mataerial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Usfda / Pmdaapproved , Brs Stent • Scaffold Material- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Ce-Approved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Usfda / Pmdaapproved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Ce Approved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Usfda / Pmdaapproved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Ce Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Usfda / Pmdaapproved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Ce Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Usfda Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Ce Approved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Usfda / Pmdaapproved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Ce Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Usfda / Pmda Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Ce Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 2-4 Mm ) • Usfda / Pmda Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 2-4 Mm ) • Ce Approved , Guide Extension Catheter- • Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Usfda / Pmda Approved , Guide Extension Catheter- •Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Ce Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Usfda / Pmda Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Ce Approved , Hydrophilic Angiography Guide Wire- • Single Nitinol Core Alloy • Tungsten Infused Polyurethane Jacket • 0.018” To .038” • Straight Tip, Angled Tipand J Tip • Regular Length And Exchange Length • Usfda / Pmda- Approved , Hydrophilic Angiography Guide Wire- • Single Nitinol Core Alloy • Tungsten Infused Polyurethane Jacket • 0.018” To .038” • Straight Tip, Angled Tipand J Tip • Regular Length And Exchange Length • Ce- Approved , Super Stiff Wire Like Amplatzer / Lunderquist • 0.018”, .035”, 0.38” • Stiff Core • Super Stiff Wire Body • Atraumatic Tip With Gradual Distal Core Taper • Ptef / Teflon Coating • Flat Coiled Outer Wire Construction • Regular Length And Exchange Length • Usfda / Pmda- Approved , Super Stiff Wire Like Amplatzer / Lunderquist • 0.018”, .035”, 0.38” • Stiff Core • Super Stiff Wire Body • Atraumatic Tip With Gradual Distal Core Taper • Ptef / Teflon Coating • Flat Coiled Outer Wire Construction • Regular Length And Exchange Length • Ce- Approved , Ptca Guide Wire • Core Material Elastinite Nitinol For Excellent Flexibility And Durability. • Shaping Ribbon For Excellent For Excellent Shape Retention. • Atraumatic Tip Load Less Than 0.65 Gm. • Regular Length, Regular Shaft Support And Floppy Tip. • Usfda / Pmda Approved , Ptca Guide Wire • Core Material Elastinite Nitinol For Excellent Flexibility And Durability. • Shaping Ribbon For Excellent For Excellent Shape Retention. • Atraumatic Tip Load Less Than 0.65 Gm. • Regular Length, Regular Shaft Support And Floppy Tip. • Ceapproved , Ptca Guide Wire • Regular Workhorse Guide Wire With Responsease, Core Grind Technology, And 3.00 Cm Palladium-Rhenium Radio Opaque Distal Tip. • Tip Load >0.8Gm. • Regular Length 190Cm And 300 Cm. • Usfda / Pmda Approved , Ptca Guide Wire • Regular Workhorse Guide Wire With Responsease, Core Grind Technology, And 3.00 Cm Palladium-Rhenium Radio Opaque Distal Tip. • Tip Load >0.8Gm. • Regular Length 190Cm And 300 Cm. • Ceapproved , Ptca Guide Wire • Workhorse Guide Wire With Triple Spring 304 V Stainless Steel With Niti Distal Core And Cold Working Rotatory Swagging Tip. • Tip Load 0.6Gm. – 0.8Gm. •Regular Length 190Cm And 300 Cm. • Usfda / Pmda Approved , Ptca Guide Wire • Workhorse Guide Wire With Triple Spring 304 V Stainless Steel With Niti Distal Core And Cold Working Rotatory Swagging Tip. • Tip Load 0.6Gm. – 0.8Gm. •Regular Length 190Cm And 300 Cm. • Ce Approved , Ptca Guide Wire For Cto • Latest Cto Indicated Guide Wire With Core Material Durasteel, Hydrophilic Coating And Uncoated Tip For Better Tactile Feedback. • Tip Load 11.0 Gm. – 14.0 Gm • Penetration Power 167, 224 Kg / In2 • Usfda / Pmda Approved , Ptca Guide Wire For Cto • Latest Cto Indicated Guide Wire With Core Material Durasteel, Hydrophilic Coating And Uncoated Tip For Better Tactile Feedback. • Tip Load 11.0 Gm. – 14.0 Gm • Penetration Power 167, 224 Kg / In2 • Ceapproved , Ptca Balloon • Semi Compliant Coronary Balloon With Slim Seal Technology On Distal Tip. • Crossing Profile < 0.021” • Lesion Entry Profile < 0.017” • Nominal Pressure 8 Atm. And Rbp 14 Atm. • Available In Diameter 1.20Mm -4.00Mm And Length 6.00Mm – 30.00Mm. • Available In Both Rx And Otw. • Usfda / Pmda Approved. , Ptca Balloon • Semi Compliant Coronary Balloon With Slim Seal Technology On Distal Tip. • Crossing Profile < 0.021” • Lesion Entry Profile < 0.017” • Nominal Pressure 8 Atm. And Rbp 14 Atm. • Available In Diameter 1.20Mm -4.00Mm And Length 6.00Mm – 30.00Mm. • Available In Both Rx And Otw. • Ceapproved. , Ptca Balloon • Non Compliant Coronary Balloon With Slim Seal Technology On Distal Tip. • Crossing Profile < 0.021” • Lesion Entry Profile < 0.017” • Nominal Pressure 8 Atm. And Rbp 14 Atm. • Available In Diameter 1.20Mm -4.00Mm And Length 6.00Mm – 30.00Mm. • Available In Both Rx And Otw. • Usfda / Pmda Approved , Ptca Balloon • Non Compliant Coronary Balloon With Slim Seal Technology On Distal Tip. • Crossing Profile < 0.021” • Lesion Entry Profile < 0.017” • Nominal Pressure 8 Atm. And Rbp 14 Atm. • Available In Diameter 1.20Mm -4.00Mm And Length 6.00Mm – 30.00Mm. • Available In Both Rx And Otw. • Ceapproved , Ptca Balloon • Non Compliant Coronary Balloon With Slim Seal Technology On Distal Tip. • Crossing Profile < 0.021” • Lesion Entry Profile < 0.018” • Nominal Pressure 8 Atm. And Rbp 14 Atm. • Available In Diameter 2.25Mm -5.00Mm And Length 6.00Mm – 30.00Mm. • Available In Both Rx And Otw. • Usfda / Pmda Approved , Ptca Balloon • Non Compliant Coronary Balloon With Slim Seal Technology On Distal Tip. • Crossing Profile < 0.021” • Lesion Entry Profile < 0.018” • Nominal Pressure 8 Atm. And Rbp 14 Atm. • Available In Diameter 2.25Mm -5.00Mm And Length 6.00Mm – 30.00Mm. • Available In Both Rx And Otw. • Ceapproved , Ptca Balloon • Semi Compliant Balloon With Tri Fold Balloon Design For Good Rewrap And Laser Bond Technology On Distal Tip. • Crossing Profile < 0.021” • Tip Entry Profile < 0.017” • Available In Diameter 1.20 Mm To 4.0 Mm And Length 6.00 Mm To 30.00 Mm. • Usfda / Pmda Approved. , Ptca Balloon • Semi Compliant Balloon With Tri Fold Balloon Design For Good Rewrap And Laser Bond Technology On Distal Tip. • Crossing Profile < 0.021” • Tip Entry Profile < 0.017” • Available In Diameter 1.20 Mm To 4.0 Mm And Length 6.00 Mm To 30.00 Mm. • Ce Approved. , Ptca Balloon • Non Compliant Balloon With Tri Fold Balloon Design For Good Rewrap And Laser Bond Technology On Distal Tip. • Crossing Profile < 0.021” • Tip Entry Profile < 0.018” • Available In Diameter 2.00 Mm To 4.50 Mm And Length 8.00 Mm To 25.00 Mm. • Usfda / Pmda Approved , Ptca Balloon • Non Compliant Balloon With Tri Fold Balloon Design For Good Rewrap And Laser Bond Technology On Distal Tip. • Crossing Profile < 0.021” • Tip Entry Profile < 0.018” • Available In Diameter 2.00 Mm To 4.50 Mm And Length 8.00 Mm To 25.00 Mm. • Ceapproved , Ffr Pressure Wire • Should Be 0.014” Guide Wire. • System Should Work Both Wired And Wireless Radio Using Frequency Hopping Spread Spectrum To Ensure Secure Radio Connection With Pressure Wire. • Should Be Compatible With Available Quantien Ffr Measurement System. • Usfda / Pmda Approved , Ffr Pressure Wire • Should Be 0.014” Guide Wire. • System Should Work Both Wired And Wireless Radio Using Frequency Hopping Spread Spectrum To Ensure Secure Radio Connection With Pressure Wire. • Should Be Compatible With Available Quantien Ffr Measurement System. • Ce Approved , Oct Catheter • The Imaging Catheter Should Be Able To Emit Near Infra Red Light To Produce High Resolution Real Time Image. • Catheter Should Be Compatible With 0.014” Guide Wire. • Should Be Compatible With Available Optis Integrated Next Oct System • Usfda / Pmda Approved , Oct Catheter • The Imaging Catheter Should Be Able To Emit Near Infra Red Light To Produce High Resolution Real Time Image. • Catheter Should Be Compatible With 0.014” Guide Wire. • Should Be Compatible With Available Optis Integrated Next Oct System • Ce Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Should Have Bleed Back Control Valve With Twin Seals. • Bleed Back Seal And Clamp Seal Permits High Pressure Injection Up To 400 Psi. • Push Pull Knob For Single Operator Use And Complete Homeostasis. • Usfda / Pmd Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Should Have Bleed Back Control Valve With Twin Seals. • Bleed Back Seal And Clamp Seal Permits High Pressure Injection Up To 400 Psi. • Push Pull Knob For Single Operator Use And Complete Homeostasis. • Ce Approved , Orbital Atherectomy- • Single 6F 1.25Mm Diamond Coated Crown 6.5Mm Away From Tip For Treating Vessels 2.5Mm To 4.0Mm. • It Should Provide Bi-Directional Sanding & Pulsatile Forces In Orbital Motion Creates Micro Fractures To Modify Deep Calcium. • The Device Should Comes With A Combo Of 1Each Of Viper Wire Made Up Nitinol Having 0.014 Inch Tip Diameter & Length 325Cm Along With 1Each Of Viper Slide Lubricant 100Ml Capacity. • Us Fda / Pmda Approved. , Orbital Atherectomy- • Single 6F 1.25Mm Diamond Coated Crown 6.5Mm Away From Tip For Treating Vessels 2.5Mm To 4.0Mm. • It Should Provide Bi-Directional Sanding & Pulsatile Forces In Orbital Motion Creates Micro Fractures To Modify Deep Calcium. • The Device Should Comes With A Combo Of 1Each Of Viper Wire Made Up Nitinol Having 0.014 Inch Tip Diameter & Length 325Cm Along With 1Each Of Viper Slide Lubricant 100Ml Capacity. • Ce- Approved. , Console For Orbital Atherectomy- • System Shouldbe Convenient Two-Speed Controls 80, 000 Rpm & 1, 20, 000 Rpm Per Minute. • System Should Be Small Electric Operated & Fix On The Side Of The Cath Lab Tabel Or Fix On The Iv Stand Available In The Cath Lab. • System Should Be Electric-Powered Handle Allows Two-Minute Set Up And Provides Efficient Torque Transfer To The Shaft And Crown. • System Should Be Glide Assist Feature For Easier Tracking And Removal And Smoother Repositioning Of The Device. • Usfda / Pmda Approved , Console For Orbital Atherectomy- • System Shouldbe Convenient Two-Speed Controls 80, 000 Rpm & 1, 20, 000 Rpm Per Minute. • System Should Be Small Electric Operated & Fix On The Side Of The Cath Lab Tabel Or Fix On The Iv Stand Available In The Cath Lab. • System Should Be Electric-Powered Handle Allows Two-Minute Set Up And Provides Efficient Torque Transfer To The Shaft And Crown. • System Should Be Glide Assist Feature For Easier Tracking And Removal And Smoother Repositioning Of The Device. • Ce- Approved , Peripheral Mechanical Thrombectomy- Pe Specifications : Catheter : Large Lumen Aspiration With Multiple Material Transitions For Advanced Tracking Technology , With Atraumatic Tip For Circumferential Aspiration. Catheter Size : Available In 8F ( 2.67Mm Od ) With Two Working Lengths – 85 Cm And 115 Cm Catheter Type : Straight Tip And Extra Torque ( For A 360 Degree Aspiration ) Separator : Proprietary Separator Technology For Easy And Quick Aspiration, With150 Cm Length And Distal Od Of 1.83 Mm. , Peripheral Mechanical Thrombectomy Ali & Dvt Specifications : Catheter : Large Lumen Aspiration With Multiple Material Transitions For Advanced Tracking Technology , With Atraumatic Tip For Circumferential Aspiration. Catheter Size : Available In 6F ( 2.0Mm Od ) With Working Length – 135 Cm Catheter Type : Straight Tip And Extra Torque ( For A 360 Degree Aspiration ) Separator : Proprietary Separator Technology For Easy And Quick Aspiration, With175 Cm Length And Distal Od Of 1.40 Mm. Peripheral Mechanical Thrombectomy- Stemi Specifications: Catheter: Stainless Steel Hypotube At The Proximal End, Designed To Enhance Deliverability To The Desired Vesselwith Optimal Visualization And Placement. Catheter Size : 6 F Catheter Type : Low Crossing Profile Of 1.75Mm With An Id Of .044”. Separator : Proprietary Separator Technology For Easy And Quick Aspiration, With 200 Cm Length And Distal Od Of .89 Mm. , Aspiration Thrombectomy Catheter • Available In Size 6F, 7F Both, Must Have Entry Profile 0.019 Inches • Must Have 1.30 Mm Square Suction Area • Braided Polyamide Elastomer Shaft, Stainless Steel Wire Braiding And Guide Wire Type Stylet, • 6.0Mm Tip Length For Making Aspiration Inlet To Come Closer To The Target Thrombus And 10Cm-Length Depth. • Must Have Distal 40 Cm Hydrophilic Coating. • Usfda / Pmda Approved , Aspiration Thrombectomy Catheter • Available In Size 6F, 7F Both, Must Have Entry Profile 0.019 Inches • Must Have 1.30 Mm Square Suction Area • Braided Polyamide Elastomer Shaft, Stainless Steel Wire Braiding And Guide Wire Type Stylet, • 6.0Mm Tip Length For Making Aspiration Inlet To Come Closer To The Target Thrombus And 10Cm-Length Depth. • Must Have Distal 40 Cm Hydrophilic Coating. • Ce Approved , Endomyocardial Biopsy Forceps – • Stainless Steel Or Fep Coated • Two Stainless Steel Symmetrical Hinged Cutting Jaws • Three-Ring Handle & Rotational Central Ring. • Straight, Pre-Curved Or Maxi-Curved Configurations - Formable And Non-Formable Options • 1.5Mm, 1.8Mm, 2.2Mm, 2.4Mm • Usfda / Pmda Approved , Endomyocardial Biopsy Forceps – • Stainless Steel Or Fep Coated • Two Stainless Steel Symmetrical Hinged Cutting Jaws • Three-Ring Handle & Rotational Central Ring. • Straight, Pre-Curved Or Maxi-Curved Configurations - Formable And Non-Formable Options • 1.5Mm, 1.8Mm, 2.2Mm, 2.4Mm • Ce Approved , • Valve-Tavi • Self-Expanding Frame, Supra-Annular Valve Design, Bovine Pericardial Valve • Proprietary Anti-Calcification Tissue Treatment • Extended Internal Sealing Skirt • Two Rows Of Radio-Opaque Markers On Valve Frame For Implantation Guidance • Varying Radial Force Frame – Optimal Forces At 3 Parts Of The Frame • Post Dilatation Limits Of Valve Frame Equal To Approved Annulus Diameter Limit • Coronary Arteries Access - Cell Size Of = 15 French In Mid-Frame • Available In Three Sizes Of 22, 26, And 30 Mm Delivery Catheter ( System ) • Non-Braided Transparent Capsule & Flexible Shaft For Ease Of Deliverability • Unique Color-Coded Indicators For Deployment Guidance • 14 Fr, & 15Fr , Balloon Expandable Transcatheter Aortic Valve Replacement System With All Standard Accessories For Implantation Should Be Available In Standard, Intermediate Sizes And Xl Sizes Should Be Quoted With All Accessories ( Delivery System, Dilatation Balloon Catheter And Introducer Sheath ) Ce- Approved , Vascular Closure Device • Device 6 Fr, 8 Fr • Device Length 205 + 10 Mm • Device Effective Length 155 + 10 • Device Degradation Period 90 Days • Anchor Material Poly ( D, L-Lactide-Co-Glycolide ) • Device Material Pdlg Anchor, Poly Glycolic Acid ( Pga ) Suture And Bovine Type-I Collagen Plug • Device Size Compatibility- 6 Fr Device Compatible With 6 Fr And 7 Fr Introducer Sheath • 8 Fr Device Device Compatible With 8 Fr And 9 Fr Introducer Sheath • Usfda / Pmda -Approved , Vascular Closure Device • Device 6 Fr, 8 Fr • Device Length 205 + 10 Mm • Device Effective Length 155 + 10 • Device Degradation Period 90 Days • Anchor Material Poly ( D, L-Lactide-Co-Glycolide ) • Device Material Pdlg Anchor, Poly Glycolic Acid ( Pga ) Suture And Bovine Type-I Collagen Plug • Device Size Compatibility- 6 Fr Device Compatible With 6 Fr And 7 Fr Introducer Sheath • 8 Fr Device Device Compatible With 8 Fr And 9 Fr Introducer Sheath • Ce-Approved , Rotablator Burr • Size 1.25 Mm To 1.75 Mm • Compatible To Existing Machine At Rnt Mc, Udaipur • Usfda / Pmda Approved , Rotablator Burr • Size 1.25 Mm To 1.75 Mm • Compatible To Existing Machine At Rnt Mc, Udaipur • Ceapproved , Rotablator ( Rota Link Plus-Burr & Advancer ) • Size 1.25 Mm To 1.75 Mm • Compatible To Existing Machine At Rnt Mc, Udaipur • Usfda / Pmda Approved , Rotablator ( Rota Link Plus-Burr & Advancer ) • Size 1.25 Mm To 1.75 Mm • Compatible To Existing Machine At Rnt Mc, Udaipur • Ce Approved , Ivus Catheters • Compatible To Existing Machine At Rnt Mc, Udaipur • Usfda / Pmda Approved , Oct Catheters • Compatible To Existing Machine At Rnt Mc, Udaipur • Usfda / Pmda Approved , Oct Catheters • Compatible To Existing Machine At Rnt Mc, Udaipur • Ce Approved , Special Ptca Balloon –Non Complaint Coronary Balloon With Multilayer • Cross Flex Balloon Technology • Round Tip With Lesion Entry Profile Of 0.018” • Diameter 1.5Mm-5Mm And •Lengths In 6Mm- 25Mm • Skive Technology On Mid Shaft Of Dilation Catheter • Usfda / Pmda Approved , Special Ptca Balloon –Non Complaint Coronary Balloon With Multilayer • Cross Flex Balloon Technology • Round Tip With Lesion Entry Profile Of 0.018” • Diameter 1.5Mm-5Mm And •Lengths In 6Mm- 25Mm • Skive Technology On Mid Shaft Of Dilation Catheter • Ce Approved

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Mar-2024 Corrigendum Technical Bid 06-03-2024
2 06-Mar-2024 date corrigendum Date 09-03-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 2000000.0 /-
Tender Value
INR 10 Crore /-

BOQ Items

Name of Work: Rate contract ofcardic items
Sl. No. Item Description
1Rate contract ofcardiac items
2Radial Sheathwith PUNCTURE NEEDLE FOR ADULTS • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • 0.21’’ Guide wire compatible • Diameter: 4,5,6, & 7 Fr • Lengths: 11 cm (23 cm in 6 Fr) • with 21G needle • USFDA/PMDA approved
3Radial Sheathwith PUNCTURE NEEDLE FOR ADULTS • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • 0.21’’ Guide wire compatible • Diameter: 4,5,6, & 7 Fr • Lengths: 11 cm (23 cm in 6 Fr) • with 21G needle • CE - approved
4Radial Sheathwith PUNCTURE NEEDLE FOR PEDIATRIC PATIENTS • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • 0.21’’ Guide wire compatible • Diameter: 4,5, & 6 Fr • Lengths: 7.5 cm • USFDA/PMDA approved
5Radial Sheathwith PUNCTURE NEEDLE FOR PEDIATRIC PATIENTS • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • 0.21’’ Guide wire compatible • Diameter: 4,5, & 6 Fr • Lengths: 7.5 cm • CE - approved
6FEMORAL Sheathwith PUNCTURE NEEDLE FOR ADULTS • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • 0.38’’ Guide wire compatible • Diameter: 4,5,6, 7,8,9,10 & 11 Fr • Lengths: 11 cm • USFDA/PMDA approved
7FEMORAL Sheathwith PUNCTURE NEEDLE FOR ADULTS • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • 0.38’’ Guide wire compatible • Diameter: 4,5,6, 7,8,9,10 & 11 Fr • Lengths: 11 cm • CE approved
8FEMORAL Sheathwith PUNCTURE NEEDLE FOR ADULTS –MID LENGTH • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • Diameter: 6, 7, & 8 Fr • Lengths: 23 cm • With usable dilator 30 cm • USFDA/PMDA approved
9FEMORAL Sheathwith PUNCTURE NEEDLE FOR ADULTS –MID LENGTH • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • Diameter: 6, 7, & 8 Fr • Lengths: 23 cm • With usable dilator 30 cm • CE- approved
10Braided Long Sheath- • Atraumatic Tip for Carotid & Distal procedures • Haemostatic Valves (Cross Cut Valve & TBV- detachable valves for thrombus management) • Gold Coil Marker - For Distal Visibility PTFE Coating - Seamless Device Transition • Distal Hydrophilic Coated for navigability • Nylon Outer Layer with reinforced stainless-steel coil • Available in Diameter 6,7,8 Fr. and length 45cm,65cm & 9ocm. • USFDA/PMDA- approved
11Braided Long Sheath- • Atraumatic Tip for Carotid & Distal procedures • Haemostatic Valves (Cross Cut Valve & TBV- detachable valves for thrombus management) • Gold Coil Marker - For Distal Visibility PTFE Coating - Seamless Device Transition • Distal Hydrophilic Coated for navigability • Nylon Outer Layer with reinforced stainless-steel coil • Available in Diameter 6,7,8 Fr. and length 45cm,65cm & 9ocm. • CE- approved
12support catheter •Double braided stainless-steel shaft with 0.035" • guidewire with one embedded two swaged radiopaque markers. • USFDA/PMDA Approved
13support catheter • Double braided stainless-steel shaft with 0.035" • guidewire with one embedded two swaged radiopaque markers. • CE- Approved
14• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Must have 32 standards of stainless steel braid • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) • Transradial catheter shapes-TIG, TIG II, JACKY, SARAH. 4Fr.-5Fr.-6Fr. Largest Inner diameter should be of 4 Fr=1.03mm 5 Fr=1.20 mm 6 Fr=1.30 mm • USFDA/PMDA approved
15• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Must have 32 standards of stainless steel braid • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) • Transradial catheter shapes-TIG, TIG II, JACKY, SARAH. 4Fr.-5Fr.-6Fr. Largest Inner diameter should be of 4 Fr=1.03mm 5 Fr=1.20 mm 6 Fr=1.30 mm • CE -approved
16Special Guiding Catheter – • Must Have Ikari curve for radial route. • High Strength Wired braided catheter with Inner Layer of PTFE •fuoro Polymer to facilitates smoother delivery, provides robust backup. • Must have Zone technology-five Zone each fabricated from a material of different stiffness, to provide optimum engagement and backup support and soft and atraumatic tip. • Must have larger lumen. 6Fr ID .071" • Shape 3-5, Size- 4Fr to 8 Fr • Should be available with short & long tip for each curve • Must have AL, AR, JL, JR, Extra Back up, Internal Mammary, Multipurpose, straight, tiger curve, Voda • USFDA/PMDA approved
17Special Guiding Catheter – • Must Have Ikari curve for radial route. • High Strength Wired braided catheter with Inner Layer of PTFE •fuoro Polymer to facilitates smoother delivery, provides robust backup. • Must have Zone technology-five Zone each fabricated from a material of different stiffness, to provide optimum engagement and backup support and soft and atraumatic tip. • Must have larger lumen. 6Fr ID .071" • Shape 3-5, Size- 4Fr to 8 Fr • Should be available with short & long tip for each curve • Must have AL, AR, JL, JR, Extra Back up, Internal Mammary, Multipurpose, straight, tiger curve,Voda • CE- approved
18Coronary micro-Guide catheter – distal 70 cm Hydrophilic coat. • Must Have tapered stainless steel braid mesh construction and Inner PTFE Layer. • Must Have 13 CM floppy distal segment. • Must Have Distal outer diameter 1.8 Fr or less and Proximal Outer diameter 2.6Fr. • Must have 70cm distal hydrophilic coating. • Must be available in Catheter Length 130cm for antegrade approach and 150 cm for retrograde approach. • Must have Gold marker for the tip visibility • USFDA/PMDA approved
19Coronary micro-Guide catheter – distal 70 cm Hydrophilic coat. • Must Have tapered stainless steel braid mesh construction and Inner PTFE Layer. • Must Have 13 CM floppy distal segment. • Must Have Distal outer diameter 1.8 Fr or less and Proximal Outer diameter 2.6Fr. • Must have 70cm distal hydrophilic coating. • Must be available in Catheter Length 130cm for antegrade approach and 150 cm for retrograde approach. • Must have Gold marker for the tip visibility • CE approved
20Aspiration Thrombectomy Catheter • Available in Size 6F, 7F Both, Must have entry profile 0.019 inches • Must Have 1.30 mm square suction area • Braided polyamide elastomer shaft, stainless steel wire braiding and Guide wire type Stylet, • 6.0mm tip length for making aspiration inlet to come closer to the target thrombus and 10cm-length depth. • Must Have Distal 40 cm Hydrophilic coating. • USFDA/PMDA Approved
21Aspiration Thrombectomy Catheter • Available in Size 6F, 7F Both, Must have entry profile 0.019 inches • Must Have 1.30 mm square suction area • Braided polyamide elastomer shaft, stainless steel wire braiding and Guide wire type Stylet, • 6.0mm tip length for making aspiration inlet to come closer to the target thrombus and 10cm-length depth. • Must Have Distal 40 cm Hydrophilic coating. • CE Approved
22• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Inner diameter of 4 Fr.= 1.03 mm, 5Fr. = 1.20 mm, 6 Fr.=1.30 mm or more with flow rates of 12, 21,25 ml per second respectively. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) Amplatz left & right, (AL1 & 2, AR 1 & 2) multipurpose, hockey stick, IMA, pigtail- 4Fr.-5Fr.-6Fr., 7 Fr. • USFDA/PMDA approved
23• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Inner diameter of 4 Fr.= 1.03 mm, 5Fr. = 1.20 mm, 6 Fr.=1.30 mm or more with flow rates of 12, 21,25 ml per second respectively. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) Amplatz left & right, (AL1 & 2, AR 1 & 2) multipurpose, hockey stick, IMA, pigtail- 4Fr.-5Fr.-6Fr., 7 Fr. • CE - approved
24PTFE Angiography Wire • Guide wire with V stick, with choice of stainless steel core or nitinol core • Must have 40 cm to 260 cm of length and .018” to .038” diameter • With silicon coated tip and bevel indicator • USFDA/PMDA approved
25PTFE Angiography Wire • Guide wire with V stick, with choice of stainless steel core or nitinol core • Must have 40 cm to 260 cm of length and .018” to .038” diameter • With silicon coated tip and bevel indicator • CE- approved
26Hydrophilic Guidewire (Regular Length) with Mcoat technology tapered tip, single Nitinol core alloy, Tungsten-infused polyurethane jacket • hydrophilic polymer coat. One piece construction & Radiopaque polyurethane jacket. • Must be available in standard and stiff. • Must be available in .035, .032, .038, .025. .018 diameter & 150 cm, 180 cm length - Straight / Angled / 1.5mm J shape • USFDA/PMDA approved
27Hydrophilic Guidewire (Regular Length) with Mcoat technology tapered tip, single Nitinol core alloy, Tungsten-infused polyurethane jacket • hydrophilic polymer coat. One piece construction & Radiopaque polyurethane jacket. • Must be available in standard and stiff. • Must be available in .035, .032, .038, .025. .018 diameter & 150 cm, 180 cm length - Straight / Angled / 1.5mm J shape • CE approved
28Hydrophilic Guidewire (Exchange Length) with Mcoat technology tapered tip, single Nitinol core alloy, Tungsten-infused polyurethane jacket • hydrophilic polymer coat. One piece construction & Radiopaque polyurethane jacket. • Must be available in standard and stiff. • Must be available in .035, .032, .038, .025, .018 diameter and 260 & 300 cm length - Straight / Angled / 1.5mm J shape • USFDA/PMDA approved
29Hydrophilic Guidewire (Exchange Length) with Mcoat technology tapered tip, single Nitinol core alloy, Tungsten-infused polyurethane jacket • hydrophilic polymer coat. One piece construction & Radiopaque polyurethane jacket. • Must be available in standard and stiff. • Must be available in .035, .032, .038, .025, .018 diameter and 260 & 300 cm length - Straight / Angled / 1.5mm J shape • CE Approved
30PTFE Guidewire (Regular Length) • Silicon Coated Tip with choice of Stainless-steel core or Nitinol core, • 150cm, 175 cm of lengths & 0.018"" to 0.038"" diameter With Silicon Coated tip. • USFDA/PMDA Approved
31PTFE Guidewire (Regular Length) • Silicon Coated Tip with choice of Stainless-steel core or Nitinol core, • 150cm, 175 cm of lengths & 0.018"" to 0.038"" diameter With Silicon Coated tip. • CE Approved
32PTFE Guidewire – 260 cm (Exchange Length) • Silicon Coated Tip with choice of Stainless-steel core or Nitinol core, • 150cm, 175 cm of lengths & 0.018"" to 0.038"" diameter With Silicon Coated tip. • USFDA Approved
33PTFE Guidewire – 260 cm (Exchange Length) • Silicon Coated Tip with choice of Stainless-steel core or Nitinol core, • 150cm, 175 cm of lengths & 0.018"" to 0.038"" diameter With Silicon Coated tip. • CE Approved
34Special Angiography wire for radial artery anomalies • 1.5mm J tip • Diameter of 1.9 mm to 2.3 mm • Elastic Nitinol core • M coat hydrophilic material coating • 1 piece construction for one-to-one torque • Radio opaque polyurethane jacket • Tungsten mix for high visibility in X-Ray • USFDA/PMDA- approved
35Special Angiography wire for radial artery anomalies • 1.5mm J tip • Diameter of 1.9 mm to 2.3 mm • Elastic Nitinol core • M coat hydrophilic material coating • 1 piece construction for one-to-one torque • Radio opaque polyurethane jacket • Tungsten mix for high visibility in X-Ray • CE- approved
36Baby J wire with 1.5mm J tip – 260 cm • Baby J Curve Must have radius of 1.5 mm. • Super elastic Nitinol alloy, M coat hydrophilic coat, • One piece construction for 1:1 torque & Radiopaque polyurethane jacket. • Must Have Tungsten-infused polyurethane jacket. • USFDA/PMDA approved
37Baby J wire with 1.5mm J tip – 260 cm • Baby J Curve Must have radius of 1.5 mm. • Super elastic Nitinol alloy, M coat hydrophilic coat, • One piece construction for 1:1 torque & Radiopaque polyurethane jacket. • Must Have Tungsten-infused polyurethane jacket. • CE approved
38High Pressure Semi-Compliant PTCA Balloon. • Must have Low Entry Tip Profile < 0.016”. • Should have Nominal Pressure 6atm or above and RBP above 14atm. • Balloon must have P-Tech Coating & Stainless Steel Hypotube for Kink Resistant & Superior Deliverability. • Diameter1-5 mm • Quote both Monorail (Rapid Exchange) or OTW balloons. • USFDA/PMDA Approved.
39High Pressure Semi-Compliant PTCA Balloon. • Must have Low Entry Tip Profile < 0.016”. • Should have Nominal Pressure 6atm or above and RBP above 14atm. •Balloon must have P-Tech Coating & Stainless Steel Hypotube for Kink Resistant & Superior Deliverability. • Diameter1-5 mm • Quote both Monorail (Rapid Exchange) or OTW balloons. • CE- Approved.
40PTCA Balloon (Non compliant) With entry profile <0.016”, Hydrophilic coating and tapered tip, available in diameter ranging from 2.00 to 4.5 mm and lengths 5 mm to 20 mm • Core wire shaft for better push ability • USFDA /PMDA approved
41PTCA Balloon (Non compliant) With entry profile <0.016”, Hydrophilic coating and tapered tip, available in diameter ranging from 2.00 to 4.5 mm and lengths 5 mm to 20 mm • Core wire shaft for better push ability • CE-approved
42Special PTCA balloon (non-compliant). • Entry Profile <0.016”, • diameter starting from 1.75 mm-5.0 mm. • Balloon material must be nylon for controlled compliance. • Quote both monorail (rapid exchange) or OTW balloons. • USFDA/PMDA approved
43Special PTCA balloon (non-compliant). • Entry Profile <0.016”, • diameter starting from 1.75 mm-5.0 mm. • Balloon material must be nylon for controlled compliance. • Quote both monorail (rapid exchange) or OTW balloons. • CE approved
44Special PTCA Balloon for CTO • starting diameter 0.85mm with RBP 16 atm or above. • Low Entry Tip Profile < 0.015”. • Balloon Hypotube must be Stainless Steel along with having Spiral-Cut design for excellent force transmission from proximal shaft to distal tip. • Should have Extended Guide wire lumen 30cm for better pushability in the CTO lesions. • Quote both Monorail (Rapid Exchange) or OTW balloons. •USFDA/PMDA-Approved.
45Special PTCA Balloon for CTO • starting diameter 0.85mm with RBP 16 atm or above. • Low Entry Tip Profile < 0.015”. • Balloon Hypotube must be Stainless Steel along with having Spiral-Cut design for excellent force transmission from proximal shaft to distal tip. • Should have Extended Guide wire lumen 30cm for better pushability in the CTO lesions. • Quote both Monorail (Rapid Exchange) or OTW balloons. •CE-Approved.
46Special PTCA Balloon (Non-Compliant) for Post Dilation. • Must have diameter starting from 1.75mm-5.0mm. • Balloon material must be Nylon for controlled compliance. • Distal Tip must be Z-Tip for Zero Transition with conventional steerable guidewires. • Quote both Monorail (Rapid Exchange) or OTW balloons. • USFDA/PMDA Approved.
47Special PTCA Balloon (Non-Compliant) for Post Dilation. • Must have diameter starting from 1.75mm-5.0mm. • Balloon material must be Nylon for controlled compliance. • Distal Tip must be Z-Tip for Zero Transition with conventional steerable guidewires. • Quote both Monorail (Rapid Exchange) or OTW balloons. • CE- Approved.
48High Pressure (Non-Compliant) PTCA Balloon • Entry Profile <0.016”, • made up of dual layer of Nylon & Pebax material for controlled Expansion & Apposition. • Balloon must available in longest length of 22mm & 26mm. • Should have High RBP of 24 atm. Available from smallest diameter 1.5mm-5.0mm. • Quote both Monorail (Rapid Exchange) or OTW balloons. • US FDA/PMDA Approved.
49High Pressure (Non-Compliant) PTCA Balloon • Entry Profile <0.016”, • made up of dual layer of Nylon & Pebax material for controlled Expansion & Apposition. • Balloon must available in longest length of 22mm & 26mm. • Should have High RBP of 24 atm. Available from smallest diameter 1.5mm-5.0mm. • Quote both Monorail (Rapid Exchange) or OTW balloons. • CE- Approved.
50Wire Based Scoring Balloon Dilation Catheter on Non-Compliant Platform. • Entry Profile <0.016”, • Must having High RBP of 20 atm. • Available from Smallest Diameter 1.75mm onwards. • Quote both Monorail (Rapid Exchange) or OTW balloons. • USFDA/PMDA- Approved.
51Wire Based Scoring Balloon Dilation Catheter on Non-Compliant Platform. • Entry Profile <0.016”, • Must having High RBP of 20 atm. • Available from Smallest Diameter 1.75mm onwards. • Quote both Monorail (Rapid Exchange) or OTW balloons. • CE- Approved.
52Special Valvuloplasty Balloon Catheter (Tyshek type) USFDA/CE approved • Diameter 4 mm to 35 mm • Length 20 to 60 mm • Nominal pressure< 4 ATM • Should have dog boning for precise position • USFDA /PMDA approved
53Special Valvuloplasty Balloon Catheter (Tyshek type) USFDA/CE approved • Diameter 4 mm to 35 mm • Length 20 to 60 mm • Nominal pressure< 4 ATM • Should have dog boning for precise position • CE - approved
54Special PTCA Balloon Catheter of Sizes 0.75 to 0.9 mm- • Should be available in variable balloon length 8-15 mm • USFDA /PMDA approved
55Special PTCA Balloon Catheter of Sizes 0.75 to 0.9 mm- • Should be available in variable balloon length 8-15 mm • CE – approved
56Special PTCA Balloon for CTO penetration • Diameter less than 1 mm • Length less than 9 mm • USFDA /PMDA approved
57Special PTCA Balloon for CTO penetration • Diameter less than 1 mm • Length less than 9 mm • CE - approved
58Special PTCA Balloon Catheter of Sizes 0.85 mm non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated • USFDA /PMDA approved
59Special PTCA Balloon Catheter of Sizes 0.85 mm non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated • CE - approved
60Zerofold PTCA Balloon • Available in all sizes and length • USFDA /PMDA approved
61Zerofold PTCA Balloon • Available in all sizes and length • CE - approved
62Special PTCA Balloon for CTO- • Diameter should be 0.75 mm or less • USFDA /PMDA approved
63Special PTCA Balloon for CTO- • Diameter should be 0.75 mm or less • CE - approved
64Ultra high pressureplaque modification device Dual layer/RBP 35 bars/ABP bars/ABP 45 bars strictly non-compliant (only10% growth)/ and for super high pressure PTCA USFDA /PMDA approve
65Ultra high pressureplaque modification device Dual layer/RBP 35 bars/ABP bars/ABP 45 bars strictly non-compliant (only10% growth)/ and for super high pressure PTCA CE approved
66Small Non-Compliant CTO balloon/diameter 0.85 m/ Lesion Entry Profile-0.016”/RBP-21 atm/ Hydrophilic coated/ Single Proximal maker USFDA /PMDAapproved
67Small Non-Compliant CTO balloon/diameter 0.85 m/ Lesion Entry Profile-0.016”/RBP-21 atm/ Hydrophilic coated/ Single Proximal maker CE approved
68Semi complaint PTCA balloon with smallest entry profile of 0.585 mm; Tapered balloon shape, unique tri-fold wrapping technology,TR2 hydrophilic coating, available in lowest profile 1 mm diameter USFDA /PMDA approved
69Semi complaint PTCA balloon with smallest entry profile of 0.585 mm; Tapered balloon shape, unique tri-fold wrapping technology,TR2 hydrophilic coating, available in lowest profile 1 mm diameter CE approved
70Non-CompliantPTCA balloon With Highest rbp UP TO 22 atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder angle to 32 deg; available in lowest profile 1.5 mm diameter USFDA /PMDA approved
71Non-CompliantPTCA balloon With Highest rbp UP TO 22 atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder angle to 32 deg; available in lowest profile 1.5 mm diameter CE approved
72Non Compliant –balloon with nominal pressure of 12 atm and RBP of 22 atm . Flexibal thin distal tip with low entryprofile of 0.43 mm. Innovative triple layer ballon technology for high pressure resistance (outer layer of elastomer, middle layer of polyamide and inner most layer of elastomer) to provide outstanding flexibility and crossing performance. USFDA /PMDA approved
73Non Compliant –balloon with nominal pressure of 12 atm and RBP of 22 atm . Flexibal thin distal tip with low entryprofile of 0.43 mm. Innovative triple layer ballon technology for high pressure resistance (outer layer of elastomer, middle layer of polyamide and inner most layer of elastomer) to provide outstanding flexibility and crossing performance. CE approved
74Ultra low entry profile of 0.016” with hydrophilic coating for superior crossability . shorter and thinner radiopaque maker for lower crossing profile (length of 0.8 mm and thickness of 25 µm), flexible tip with short balloonbonding part of 0.4 mm. Robust and improve core wire shaft for better push ability. Smallest diameter of 1.00 mm and 5 mm length. USFDA /PMDA approved
75Ultra low entry profile of 0.016” with hydrophilic coating for superior crossability . shorter and thinner radiopaque maker for lower crossing profile (length of 0.8 mm and thickness of 25 µm), flexible tip with short balloonbonding part of 0.4 mm. Robust and improve core wire shaft for better push ability. Smallest diameter of 1.00 mm and 5 mm length. CE approved
76Non Compliant PTCA Balloon Dilatation Catheter • Tip entry profile < 0.016” (0.41 mm) Ultra low tip entry profile • Shaft diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F compatible • Balloon material : Soft multi layered polyamide • Balloon fold Trifold (2-5mm) • Hydrophilic Coating : Selective Hydrophilic coating at distal shaft including balloon tip • Length : (mm) 6 to30 • Diameter (mm) : 2 to5.0 • Nominal Pressure : 12 atm • Rated Pressure Brust (RBP) – 20 atm (18 atm for 5 mm) • Diameter growth between nominal and rated brust pressure less than 6% • Two Platinum – Iridium marks • Shaft Length : > 140 mm • USFDA /PMDA approved
77Non Compliant PTCA Balloon Dilatation Catheter • Tip entry profile < 0.016” (0.41 mm) Ultra low tip entry profile • Shaft diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F compatible • Balloon material : Soft multi layered polyamide • Balloon fold Trifold (2-5mm) • Hydrophilic Coating : Selective Hydrophilic coating at distal shaft including balloon tip • Length : (mm) 6 to 30 • Diameter (mm) : 2 to 5.0 • Nominal Pressure : 12 atm • Rated Pressure Brust (RBP) – 20 atm (18 atm for 5 mm) • Diameter growth between nominal and rated brust pressure less than 6% • Two Platinum – Iridium marks • Shaft Length : > 140 mm • CE approved
78Special PTCA Balloon for CTO lesions starting diameter 0.85 mm with RBP 16 atm or above. Balloon hypotube must be spiral-cut design for excellent force transmission from proximal shaft to distal tip. Quote both monorail (rapid exchange) or OTW balloons. USFDA /PMDAapproved
79Special PTCA Balloon for CTO lesions starting diameter 0.85 mm with RBP 16 atm or above. Balloon hypotube must be spiral-cut design for excellent force transmission from proximal shaft to distal tip. Quote both monorail (rapid exchange) or OTW balloons. CE approved
80Special PTCA Balloon ( Non-compliant) for post dilation. Must have diameter starting from 1.75 mm-5.0 mm. Balloon material must be nylon for controlled compliance. Quote both monorail (rapid exchange) or OTW balloons. USFDA /PMDAapproved
81Special PTCA Balloon ( Non-compliant) for post dilation. Must have diameter starting from 1.75 mm-5.0 mm. Balloon material must be nylon for controlled compliance. Quote both monorail (rapid exchange) or OTW balloons. CE approved
82High pressure Non-compliant PTCA Balloon for controlled plaque, expansion & apposition. Balloon must available in longest length up to 26 mm. Should have high RBP above 22 atm. Quote both monorail (rapid exchange) or OTW balloons. USFDA /PMDAapproved
83High pressure Non-compliant PTCA Balloon for controlled plaque, expansion & apposition. Balloon must available in longest length up to 26 mm. Should have high RBP above 22 atm. Quote both monorail (rapid exchange) or OTW balloons. CE approved.
84• Angiographic Double Lumen Tracking Catheter-- 4F/5F/6F For various purpose. • USFDA /PMDAapproved
85• Angiographic Double Lumen Tracking Catheter-- 4F/5F/6F For various purpose. • CE - approved
86SPECIAL PTCA GUIDE WIRE WITH DUAL COATING Should have distal hydrophilic coating and proximal hydrophobic coating. Should have wires with variable tip stiffness and variable shaft support tip load <1gm • USFDA /PMDAapproved
87SPECIAL PTCA GUIDE WIRE WITH DUAL COATING Should have distal hydrophilic coating and proximal hydrophobic coating. Should have wires with variable tip stiffness and variable shaft support tip load <1gm • CE- approved
88HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- • 0.014 inches , Nitinol alloy , With angled tip -3-5 cm long • Tip with platinum/platinum alloy for optimumvisualization •With TFE coating ,180 cm to 300cm • USFDA /PMDAapproved
89HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- • 0.014 inches , Nitinol alloy , With angled tip -3-5 cm long • Tip with platinum/platinum alloy for optimumvisualization • With TFE coating ,180 cm to 300cm • CE - approved
90STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length) • PTFE/ duraglide coated , • Distal Radio-opaque tip 3 cm long • Straight and J curve, 180 cm to 300 cm long • USFDA /PMDAapproved
91STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length) • PTFE/ duraglide coated , • Distal Radio-opaque tip 3 cm long • Straight and J curve, 180 cm to 300 cm long • CE – approved
92PTCA Guide Wire – 2 mm Silicon coated distal tip, 0.014” Diameter and 180 cm length PTCA wire • Must have Platinum coil at distal tip. • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Should have M coat hydrophilic coating up to 248 mm • Wire Should have PTFE Coating from 25 to 180 cm length. • Should be Available in 0.6 gf, 1gf & 3.6gf tip loads • Should be available in Floppy tip, Extra floppy tip, Hypercoat tip & Intermediate tip . • USFDA/PMDA approved
93PTCA Guide Wire – 2 mm Silicon coated distal tip, 0.014” Diameter and 180 cm length PTCA wire • Must have Platinum coil at distal tip. • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Should have M coat hydrophilic coating up to 248 mm • Wire Should have PTFE Coating from 25 to 180 cm length. • Should be Available in 0.6 gf, 1gf & 3.6gf tip loads • Should be available in Floppy tip, Extra floppy tip, Hypercoat tip & Intermediate tip . • CE approved
94Extra Floppy PTCA Guide Wire – 2 mm Silicon coated distal tip, 0.014” Diameter and 180/300 cm length • Must have Platinum coil at distal tip. Balance of Hydrophilic and Hydrophobic coating • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Must have PTFE Coating from 25 to 180 cm length. & Mucus coat hydrophilic coating up to 248 mm • Should have 0.6-gram force tip loads • USFDA/PMDA approved
95Extra Floppy PTCA Guide Wire – 2 mm Silicon coated distal tip, 0.014” Diameter and 180/300 cm length • Must have Platinum coil at distal tip. Balance of Hydrophilic and Hydrophobic coating • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Must have PTFE Coating from 25 to 180 cm length. & Mucus coat hydrophilic coating up to 248 mm • Should have 0.6-gram force tip loads • CE approved
96Floppy Tip PTCA Guide Wire – 2 mm Silicon coated distal tip, 0.014” Diameter and 180 cm length. • Must have Platinum coil at distal tip. Balance of Hydrophilic and Hydrophobic coating • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Must have M coat hydrophilic coating up to 248 mm, & PTFE Coating from 25 to 180 cm length. • Should have 1 gram force tip loads • USFDA/PMDA Approved
97Floppy Tip PTCA Guide Wire – 2 mm Silicon coated distal tip, 0.014” Diameter and 180 cm length. • Must have Platinum coil at distal tip. Balance of Hydrophilic and Hydrophobic coating • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Must have M coat hydrophilic coating up to 248 mm, & PTFE Coating from 25 to 180 cm length. • Should have 1 gram force tip loads • CE Approved
98Hypercoat PTCA Guide Wire with 9.7-gram force Rail Support– Mucus coated hydrophilic distal tip, 0.014” Diameter and 180/300 cm length • Must have Platinum coil at distal tip. 14 MM Tip shape length. • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Must have M coat hydrophilic coating up to 250 mm & PTFE Coating from 25 to 180 cm length. • Should have 1-gram fore tip load • USFDA/PMDA Approved
99Hypercoat PTCA Guide Wire with 9.7-gram force Rail Support– Mucus coated hydrophilic distal tip, 0.014” Diameter and 180/300 cm length • Must have Platinum coil at distal tip. 14 MM Tip shape length. • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Must have M coat hydrophilic coating up to 250 mm & PTFE Coating from 25 to 180 cm length. • Should have 1-gram fore tip load • CE Approved
100CTO Stiff PTCA Guide Wire - 3.6-gram Force tip load – 2 mm Silicon coated distal tip, 0.014” Diameter and 180 cm length. • Must have Platinum coil at distal tip. Balance of Hydrophilic and Hydrophobic coating • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Must have M coat hydrophilic coating up to 248 mm & PTFE Coating from 25 to 180 cm length. • Should have 3.6-gram fore tip load • USFDA/PMDA Approved
101CTO Stiff PTCA Guide Wire - 3.6-gram Force tip load – 2 mm Silicon coated distal tip, 0.014” Diameter and 180 cm length. • Must have Platinum coil at distal tip. Balance of Hydrophilic and Hydrophobic coating • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Must have M coat hydrophilic coating up to 248 mm & PTFE Coating from 25 to 180 cm length. • Should have 3.6-gram fore tip load • CE Approved
102PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE - • USFDA /PMDAapproved
103PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE - • CE – approved
104EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES – • USFDA /PMDAapproved
105EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES – • CE - approved
106PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION – • USFDA /PMDAapproved
107PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION – • CE - approved
108Specialized PTCA Guide wire for retrograde approach & CTO – 0.014" One Piece core wire with jointless spring coil 22cm polymer sleeve lengthwith slip coat coating over the polymer sleeve, tip load1gand 0.8g, 180cm length, tip radiopacity 3cm • USFDA /PMDAapproved
109Specialized PTCA Guide wire for retrograde approach & CTO – 0.014" One Piece core wire with jointless spring coil 22cm polymer sleeve lengthwith slip coat coating over the polymer sleeve, tip load1gand 0.8g, 180cm length, tip radiopacity 3cm • CE - approved
110Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm. • USFDA /PMDAapproved
111Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm. • CE - approved
112Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm. • USFDA /PMDAapproved
113Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm. • CE - approved
114Specialized PTCA Guide wire for retrograde approach & CTO – 0.014" One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cm • USFDA /PMDAapproved
115Specialized PTCA Guide wire for retrograde approach & CTO – 0.014" One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cm • CE - approved
116Specialized PTCA Guide wire for retrograde approach & CTO – 0.014" One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cm • USFDA /PMDAapproved
117Specialized PTCA Guide wire for retrograde approach & CTO – 0.014" One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cm • CE - approved
118Specialized PTCA Guide wire for retrograde approach & CTO – Non hydrophilic coated tapered tip .009" with a tip load of 9gm and tip radiopacity of 20cm • USFDA /PMDAapproved
119Specialized PTCA Guide wire for retrograde approach & CTO – Non hydrophilic coated tapered tip .009" with a tip load of 9gm and tip radiopacity of 20cm • CE - approved
120Specialized PTCA Guidewire for retrograde approach & – Dedicated guidewire for externalization with tip load of 3g, length 330cm • USFDA /PMDAapproved
121Specialized PTCA Guidewire for retrograde approach & – Dedicated guidewire for externalization with tip load of 3g, length 330cm • CE - approved
122Specialized PTCA Guide wire for retrograde approach & CTO– One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009" l, tip load 9g ,180cm length, tip radiopacity 20cm • USFDA /PMDAapproved
123Specialized PTCA Guide wire for retrograde approach & CTO– One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009" l, tip load 9g ,180cm length, tip radiopacity 20cm • CE - approved
124Specialized PTCA Guide wire for retrograde approach & CTO– 0.014" One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cm • USFDA /PMDAapproved
125Specialized PTCA Guide wire for retrograde approach & CTO– 0.014" One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cm • CE - approved
126Specialized PTCA Guide wire for retrograde approach & CTO – 0.014" One Piece core wire with jointless spring coil tapering to 0.009"16cm polymer sleeve lengthwith slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cm • USFDA /PMDAapproved
127Specialized PTCA Guide wire for retrograde approach & CTO – 0.014" One Piece core wire with jointless spring coil tapering to 0.009"16cm polymer sleeve lengthwith slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cm • CE - approved
128Specialized PTCA Guide wire for retrograde approach & CTO – PTCA Guide Wire with SION TECH Technology -Tapered Type, Polymersleeve, TipLoad 0.6-1.0g • USFDA /PMDAapproved
129Specialized PTCA Guide wire for retrograde approach & CTO – PTCA Guide Wire with SION TECH Technology -Tapered Type, Polymersleeve, TipLoad 0.6-1.0g • CE - approved
130Specialized PTCA Guide wire for retrograde approach & CTO – 0.010" One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tipwith a tip load of1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm, • USFDA /PMDAapproved
131Specialized PTCA Guide wire for retrograde approach & CTO – 0.010" One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tipwith a tip load of1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm, • CE - approved
132PTCA Guide Wire-DuraSteel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 1.5 gm to 4.1.gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity. • USFDA /PMDAapproved
133PTCA Guide Wire-DuraSteel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 1.5 gm to 4.1.gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity. • CE - approved
134Guidewire GT-Angioplasty •0.012, 0.014 , 0.016 & 0.018 • guidewire with outstanding torque control, • extremely flexible excellent visibility • available in tip angle of 45,90 and double angle 90+150. • USFDA/PMDA Approved
135Guidewire GT-Angioplasty •0.012, 0.014 , 0.016”& 0.018 • guidewire with outstanding torque control, • extremely flexible excellent visibility • available in tip angle of 45,90 and double angle 90+150. • CE- Approved
136Workhorse Guide wire with Dura steel Core, Responses Core Grind Technology with Hydrophilic coating and 1cm uncoated distal tip for tactile feedback available in multiple variants with same tip load of 0.9gm • USFDA /PMDAapproved
137Workhorse Guide wire with Dura steel Core, Responses Core Grind Technology with Hydrophilic coating and 1cm uncoated distal tip for tactile feedback available in multiple variants with same tip load of 0.9gm • CE - approved
138PTCA Guide Wire-Dura Steel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 0.8 gm to 1.2 gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity. • USFDA /PMDAapproved
139PTCA Guide Wire-Dura Steel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 0.8 gm to 1.2 gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity. • CE- approved
140Peripheral wire 0.014- • Stainless steel core wire • Hydrophilic & hydrophobic coating • Tip load – 3 gm & 6 gm • US FDA approved • Wire length- 190 cm & 300 cm • USFDA /PMDAapproved
141Peripheral wire 0.014- • Stainless steel core wire • Hydrophilic & hydrophobic coating • Tip load – 3 gm & 6 gm • US FDA approved • Wire length- 190 cm & 300 cm • CE - approved
142Peripheral wire 0.018- • 0.018” guide wire with Stainless steel core wire • Hydrophilic & hydrophobic coating • Tip load – 7.6 gm & 6.5 gm • US FDA approved • Wire length- 150 cm, 200 & 300 cm • USFDA /PMDAapproved
143Peripheral wire 0.018- • 0.018” guide wire with Stainless steel core wire • Hydrophilic & hydrophobic coating • Tip load – 7.6 gm & 6.5 gm • US FDA approved • Wire length- 150 cm, 200 & 300 cm • CE - approved
144CTO Wire 0.014” • 0.014” weighted tip CTO guide wire with stainless steel core • Hydrophilic & Hydrophobic coating • Tip load- 12gm, 18 gm, 25 gm, 30 gm • Wire lengths-190 cm & 300 cm • USFDA /PMDAapproved
145CTO Wire 0.014” • 0.014” weighted tip CTO guide wire with stainless steel core • Hydrophilic & Hydrophobic coating • Tip load- 12gm, 18 gm, 25 gm, 30 gm • Wire lengths-190 cm & 300 cm • CE - approved
146CTO Wire 0.018” • 0.018” weighted tip CTO guide wire with stainless steel core • Hydrophilic & Hydrophobic coating • Tip load- 12gm, 18 gm, 25 gm, 30 gm • USFDA /PMDAapproved Wire lengths-190 cm & 300 cm
147CTO Wire 0.018” • 0.018” weighted tip CTO guide wire with stainless steel core • Hydrophilic & Hydrophobic coating • Tip load- 12gm, 18 gm, 25 gm, 30 gm • CE-approved Wire lengths-190 cm & 300 cm
148Peripheral GW 0.035” • Moderate rail support • length - 180-260 cm • Tip- spring coil • USFDA /PMDAapproved
149Peripheral GW 0.035” • Moderate rail support • length - 180-260 cm • Tip- spring coil • CE- approved
150Peripheral GW 0.035” • Extra support rail strength • length - 75-260 cm • Tip- spring coil • USFDA /PMDAapproved
151Peripheral GW 0.035” • Extra support rail strength • length - 75-260 cm • Tip- spring coil • CE- approved
152Backup Meier wire-0.035” • Should have extra stiff shaft to support AAA device • Should have very flexible and soft distal tip to avoid aortic perforation/vessel trauma • Should have radiopaque tip for excellent visibility, PTFE coated proximal shaft for frictionless advancement • Should have choice of“J” and“C” tip shape with 182 cmand 260/300 cm • USFDA /PMDAapproved
153Backup Meier wire-0.035” • Should have extra stiff shaft to support AAA device • Should have very flexible and soft distal tip to avoid aortic perforation/vessel trauma • Should have radiopaque tip for excellent visibility, PTFE coated proximal shaft for frictionless advancement • Should have choice of“J” and“C” tip shape with 182 cmand 260/300 cm • CE - approved
154Hydrophilic maker wire-0.035”- • Should have single piece core with radiopaque polyurethane jacket and Glidex coated hydrophilic coating. • 4 distal platinum magic markers spaced at 1 cm for improved visualization • Single piece core design to have better steer ability, push ability and torque transmission. • USFDA /PMDAapproved
155Hydrophilic maker wire-0.035”- • Should have single piece core with radiopaque polyurethane jacket and Glidex coated hydrophilic coating. • 4 distal platinum magic markers spaced at 1 cm for improved visualization • Single piece core design to have better steer ability, push ability and torque transmission. • CE- approved
156Balloons-NC workhorse(0.035” wire) • Should be non-compliant/ semi compliant. RBP of 20-24 atm (3-8 mm balloon), 14-18 atm (9-12 mm Balloon) • Should have high rated burst pressure with scratch/puncture resistant pebax material • Dual lumen shaft with balloon laser bonded and short atraumatic tapered tip • Should have lubricious medi –glide coating and balloon material • Should have good re-wrape and low tip profile • Should be 5F (3-7 mm balloon) /6F(8-10 mm balloon/7F (12 mm balloon) sheath and 0.035” wire compatible • Should have min lesion entry profile of 0.040” (1.016 mm) • Should have choice of long balloon length 20 mm to 200 mm • USFDA /PMDAapproved
157Balloons-NC workhorse(0.035” wire) • Should be non-compliant/ semi compliant. RBP of 20-24 atm (3-8 mm balloon), 14-18 atm (9-12 mm Balloon) • Should have high rated burst pressure with scratch/puncture resistant pebax material • Dual lumen shaft with balloon laser bonded and short atraumatic tapered tip • Should have lubricious medi –glide coating and balloon material • Should have good re-wrape and low tip profile • Should be 5F (3-7 mm balloon) /6F(8-10 mm balloon/7F (12 mm balloon) sheath and 0.035” wire compatible • Should have min lesion entry profile of 0.040” (1.016 mm) • Should have choice of long balloon length 20 mm to 200 mm • CE - approved
158Balloons -0.018”/0.014” wire compatible – • Should be 4F/5F sheath and 0.018”/0.014” wire compatible with choice of OTW/Monorail delivery system • Should be non-compliant/ semi compliant. • Should have high rated burst pressure with scratch/puncture resistant pebax material • Should have lowest tip entry profile of not more than 0.022” and good 5 fold re-wrap design • Should haveexcellent coulum support with balloon laser bonded and short atraumatic tapered tip • Should have full length tapered core wire for enhancd pushability and kink resistance • Should have balloon length starting from 10 mm and balloon diameter from 3 mm to 10 mm. • USFDA /PMDAapproved
159Balloons -0.018”/0.014” wire compatible – • Should be 4F/5F sheath and 0.018”/0.014” wire compatible with choice of OTW/Monorail delivery system • Should be non-compliant/ semi compliant. • Should have high rated burst pressure with scratch/puncture resistant pebax material • Should have lowest tip entry profile of not more than 0.022” and good 5 fold re-wrap design • Should haveexcellent coulum support with balloon laser bonded and short atraumatic tapered tip • Should have full length tapered core wire for enhancd pushability and kink resistance • Should have balloon length starting from 10 mm and balloon diameter from 3 mm to 10 mm. • CE - approved
160Distal embolic protection device-Carotid/SVG- • (One size for all carotids) • Eccentric filter with nitinol loop for 360 degree wall apposition • Rx.014 6F sheath compatible • 190 cm extra support wire • Uniform micro pore size of 110 micron pore size with 1 mm pore free zone • Non thrombogenic nylon membrane with hydrophilic coating • Shouls allow optimal filtration in vessels 3-5.5 mm size USFDA /PMDAapproved
161Distal embolic protection device-Carotid/SVG- • (One size for all carotids) • Eccentric filter with nitinol loop for 360 degree wall apposition • Rx.014 6F sheath compatible • 190 cm extra support wire • Uniform micro pore size of 110 micron pore size with 1 mm pore free zone • Non thrombogenic nylon membrane with hydrophilic coating • Shouls allow optimal filtration in vessels 3-5.5 mm size • CE- approved
162Balloon expandable stent-Renal (small Diameter)- • Should be low profile, 6F guide and 0.014” wire compatible, monorail system • Should have high consistent radial strength, high flexibility, enhanced radiopacity • Should have architecture which offers excellent lumen coverage and conformability • Should have increased support and radial strength and proximal end for ostial lesion • Stent should be premounted on semicompliant balloon catheter • Stent Dia 4-7 mm, length 15 & 19, catheter length 90 & 150 cm. • Should have crimping technology which ensures no stent slippage from balloon. • USFDA /PMDAapproved
163Balloon expandable stent-Renal (small Diameter)- • Should be low profile, 6F guide and 0.014” wire compatible, monorail system • Should have high consistent radial strength, high flexibility, enhanced radiopacity • Should have architecture which offers excellent lumen coverage and conformability • Should have increased support and radial strength and proximal end for ostial lesion • Stent should be premounted on semicompliant balloon catheter • Stent Dia 4-7 mm, length 15 & 19, catheter length 90 & 150 cm. • Should have crimping technology which ensures no stent slippage from balloon. • CE - approved
164Balloon Expandable Stent- Large diameter- • Should have high consistent radial strength, high flexibility, enhanced radiopacity • Should have architecture which offers excellent lumen coverage and conformability • Should have low foreshortening, low recoil. • Stent should be premounted on non compliant balloon catheter to avoid dogboning and proper scaffolding • Should have dual lumen catheter design for faster deflation • Stent Dia 5-10 mm, length 27,37,57, catheter length 135 cm. • Should have crimping technology which ensures no stent slippage from balloon. • USFDA /PMDAapproved
165Balloon Expandable Stent- Large diameter- • Should have high consistent radial strength, high flexibility, enhanced radiopacity • Should have architecture which offers excellent lumen coverage and conformability • Should have low foreshortening, low recoil. • Stent should be premounted on non compliant balloon catheter to avoid dogboning and proper scaffolding • Should have dual lumen catheter design for faster deflation • Stent Dia 5-10 mm, length 27,37,57, catheter length 135 cm. • Should have crimping technology which ensures no stent slippage from balloon. • CE - approved
166Self expandable stent for carotid artery stenting- • Self expending elgilloy stent with closed cell design/ auto tapered design. • Monorail, 0.014” wire & 6F sheath compatible • Recons trainable braided stent • Shaft length 135 cm • Dia-6-9 mm • USFDA /PMDAapproved
167Self expandable stent for carotid artery stenting- • Self expending elgilloy stent with closed cell design/ auto tapered design. • Monorail, 0.014” wire & 6F sheath compatible • Recons trainable braided stent • Shaft length 135 cm • Dia-6-9 mm • CE - approved
168Self expandable stent- • Should be laser cut self expending nitinol stent with proximal end distal makers • Should have hybrid cell design which promotes a balance of radial strength and flexibility. • Should have controlled release/deployment mechanism to ensure precise placement and low foreshortening. • Should be 6F sheath and 0.035” wire compatible across sent size matrix. • USFDA /PMDAapproved
169Self expandable stent- • Should be laser cut self expending nitinol stent with proximal end distal makers • Should have hybrid cell design which promotes a balance of radial strength and flexibility. • Should have controlled release/deployment mechanism to ensure precise placement and low foreshortening. • Should be 6F sheath and 0.035” wire compatible across sent size matrix. • CE - approved
170Peripheral self expanding drug eluting stent- • Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA • Triaxial delivery system • Hybrid cell architecture with open and close celldesisn • Easy deployment with thumbwheel & pull grip • 6F sheath compatibility • Dia-6 &10 mm • Length – 40,60,80,100,120 mm • USFDA /PMDAapproved
171Peripheral self expanding drug eluting stent- • Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA • Triaxial delivery system • Hybrid cell architecture with open and close celldesisn • Easy deployment with thumbwheel & pull grip • 6F sheath compatibility • Dia-6 &10 mm • Length – 40,60,80,100,120 mm • CE approved
172Peripheral self expanding stent SFA- • Easy development with thumbwheel & pull grip • 6F sheath compatibility • Dia- 5,6,7,8mm • Length – 40,60,80,100,120,150 mm • USFDA /PMDAapproved
173Peripheral self expanding stent SFA- • Easy development with thumbwheel & pull grip • 6F sheath compatibility • Dia- 5,6,7,8mm • Length – 40,60,80,100,120,150 mm • CE- approved
174PVA Particles- • Should be made of polyvinyalcohol • Should have uniquely shaped and consistent sized particles. • USFDA /PMDAapproved
175PVA Particles- • Should be made of polyvinyalcohol • Should have uniquely shaped and consistent sized particles. • CE - approved
176ASD CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use • Device made of biologically inert material • Self-centering, detachable device with delivery • Cable • Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40 mm) • USFDA /PMDAapproved
177ASD CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use • Device made of biologically inert material • Self-centering, detachable device with delivery • Cable • Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40 mm) • CE - approved
178ASD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM • USFDA /PMDAapproved
179ASD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM • CE - approved
180ASD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM • DCGI - approved
181DELIVERY SHEATH FOR ASD CLOSURE DEVICE – • Compatible with the device mentioned above • USFDA /PMDAapproved
182DELIVERY SHEATH FOR ASD CLOSURE DEVICE – • Compatible with the device mentioned above • CE- approved
183ASD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh sewn with PTFE membrane available in all sizes • USFDA /PMDAapproved
184ASD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh sewn with PTFE membrane available in all sizes • CE - approved
185ASD - Multi Fenestrated (Cribriform) Occluders, • self-expandable double disc made up of soft nitinol wire mesh • two flat discs and waist of 3mm. • matched disc diameters • Polyester fabric sewn into each disc • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40mm) • USFDA /PMDAapproved
186ASD - Multi Fenestrated (Cribriform) Occluders, • self-expandable double disc made up of soft nitinol wire mesh • two flat discs and waist of 3mm. • matched disc diameters • Polyester fabric sewn into each disc • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40mm) • CE - approved
187LEFT ATRIAL APPENDAGE CLOSURE DEVICE • USFDA /PMDAapproved
188LEFT ATRIAL APPENDAGE CLOSURE DEVICE • CE - approved
189PFO CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use • Device made of biologically inert material • Available in all the sizes • USFDA /PMDAapproved
190PFO CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use • Device made of biologically inert material • Available in all the sizes • CE - approved
191PFO CLOSURE DEVICES WITHOUT DELIVERY SYSTEM – • USFDA /PMDAapproved
192PFO CLOSURE DEVICES WITHOUT DELIVERY SYSTEM – • CE- approved
193DELIVERY SHEATH FOR PFO CLOSURE DEVICE – • Compatible with the device above • USFDA /PMDAapproved
194DELIVERY SHEATH FOR PFO CLOSURE DEVICE – • Compatible with the device above • CE - approved
195SIZING BALLOON FOR DEVICE CLOSURE – CIRCULAR SHAPE • USFDA /PMDAapproved
196SIZING BALLOON FOR DEVICE CLOSURE – CIRCULAR SHAPE • CE - approved
197SIZING BALLOON FOR DEVICE CLOSURE – OVAL SHAPED • USFDA /PMDAapproved
198SIZING BALLOON FOR DEVICE CLOSURE – OVAL SHAPED • CE- approved
199SIZING PLATE FOR DEVICE CLOSURE – • USFDA /PMDAapproved
200SIZING PLATE FOR DEVICE CLOSURE – • CE -approved
201DELIVERY CABLE FOR ASD/VSD/PDA DEVICES – • USFDA /PMDAapproved
202DELIVERY CABLE FOR ASD/VSD/PDA DEVICES – • CE- approved
203RETRIEVERS FOR ASD/VSD/PDA DEVICES – • USFDA /PMDAapproved
204RETRIEVERS FOR ASD/VSD/PDA DEVICES – • CE- approved
205SHEATH FOR RETRIVAL OF DEVICES – • USFDA /PMDAapproved
206SHEATH FOR RETRIVAL OF DEVICES – • CE- approved
207AMPLATZER PLUG- • USFDA /PMDAapproved
208AMPLATZER PLUG- • CE- approved
209LEFT ATRIAL APENDAGE CLOSURE DEVICE- • USFDA /PMDAapproved
210LEFT ATRIAL APENDAGE CLOSURE DEVICE- • CE- approved
211VSD CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use • Device made of biologically inert material • Self-centering, detachable device with delivery cable • Available in all the sizes (6 mm – 40 mm) • USFDA /PMDAapproved
212VSD CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use • Device made of biologically inert material • Self-centering, detachable device with delivery cable • Available in all the sizes (6 mm – 40 mm) • CE-approved
213VSD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM – • USFDA /PMDAapproved
214VSD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM – • CE-approved
215DELIVERY SHEATH FOR VSD CLOSURE DEVICE – • Compatible with the device in item above • USFDA /PMDAapproved
216DELIVERY SHEATH FOR VSD CLOSURE DEVICE – • Compatible with the device in item above • CE-approved
217VSD Closure device with delivery system :-Elongatable waist Soft Woven meshLow delivery profile as low as 4F and maximum upo to 7 FDouble sided screw for retrograde or antegrade approachAvailable in all sizes • USFDA /PMDAapproved
218VSD Closure device with delivery system :-Elongatable waist Soft Woven meshLow delivery profile as low as 4F and maximum upo to 7 FDouble sided screw for retrograde or antegrade approachAvailable in all sizes • CE-approved
219Membranous VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane • Non concentric design • The device should be delivered using a pusher catheter from venous approch • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • available in all sizes • USFDA /PMDAapproved
220Membranous VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane • Non concentric design • The device should be delivered using a pusher catheter from venous approch • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • available in all sizes • CE-approved
221Muscular VSD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membrane • Symmetric, Asymmetric and eccentric forms Waist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • available in all sizes • USFDA /PMDAapproved
222Muscular VSD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membrane • Symmetric, Asymmetric and eccentric forms Waist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • available in all sizes • CE-approved
223Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane • Symmetric, double discWaist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • available in all sizes • USFDA /PMDAapproved
224Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane • Symmetric, double discWaist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • available in all sizes • CE-approved
225Post infarction Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane • Symmetric, double disc • Waist length should be 10 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • available in all sizes • USFDA /PMDAapproved
226Post infarction Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane • Symmetric, double disc • Waist length should be 10 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • available in all sizes • CE-approved
227PDA CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use • Device made of biologically inert material (nitinol) • Self-centering, detachable device with delivery • cable • Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR conditional up to 3 Tesla • Available in all the sizes • USFDA /PMDAapproved
228PDA CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use • Device made of biologically inert material (nitinol) • Self-centering, detachable device with delivery • cable • Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR conditional up to 3 Tesla • Available in all the sizes • CE-approved
229PDA CLOSURE DEVICES WITHOUT DELIVERY SYSTEM • USFDA /PMDAapproved
230PDA CLOSURE DEVICES WITHOUT DELIVERY SYSTEM • CE-approved
231DELIVERY SHEATH FOR PDA CLOSURE DEVICE – • Compatible with the device mentioned above • USFDA /PMDAapproved
232DELIVERY SHEATH FOR PDA CLOSURE DEVICE – • Compatible with the device mentioned above • CE-approved
233PDA Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membraneAvailable in all sizes • USFDA /PMDAapproved
234PDA Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membraneAvailable in all sizes • CE-approved
235PDA occluder with double disc :- • Made up of biologicallyinert material (nitinol) • Symmetric disc design • Fabric free technology • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • USFDA /PMDAapproved
236PDA occluder with double disc :- • Made up of biologicallyinert material (nitinol) • Symmetric disc design • Fabric free technology • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • CE-approved
237PDA occluder with double disc (for neonates) :- • Made up of biologicallyinert material (nitinol) • Symmetric disc design – low profile with low profiledelivery catheter of 4 Fr. • Tightly woven single layer mesh • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • USFDA /PMDAapproved
238PDA occluder with double disc (for neonates) :- • Made up of biologicallyinert material (nitinol) • Symmetric disc design – low profile with low profiledelivery catheter of 4 Fr. • Tightly woven single layer mesh • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching. • MR. conditional up to 3 Tesla • CE-approved
239EMBOLISATION COILS (0.018 INCH) - • Sizes ranging from 2 x 2 to 15 x 15 • USFDA /PMDAapproved
240EMBOLISATION COILS (0.018 INCH) - • Sizes ranging from 2 x 2 to 15 x 15 • CEapproved
241Embolisation Coils - • Should be 0.014/0.018” compatible • Should be made of platinum with synthetic • fibres • Should be non tapering/straight • Should be MR compatible • Should be available in any or the following diameters: 2-10 mm • Should be of various lengths; the length of the coil at each diameter should be stated • USFDA /PMDAapproved
242Embolisation Coils - • Should be 0.014/0.018” compatible • Should be made of platinum with synthetic • fibres • Should be non tapering/straight • Should be MR compatible • Should be available in any or the following diameters: 2-10 mm • Should be of various lengths; the length of the coil at each diameter should be stated • CE-approved
243Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters ) With delivery system • USFDA /PMDAapproved
244Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters ) With delivery system • CE-approved
245PediatricFemoral Sheath 4 Fr. • USFDA /PMDAapproved
246PediatricFemoral Sheath 4 Fr. • CE-approved
247Catheters for paediatric intervention • 4 Fr. • JL/JR/MP/pigtail • USFDA /PMDAapproved
248Catheters for paediatric intervention • 4 Fr. • JL/JR/MP/pigtail • CE-approved
249BMV Balloon Catheter • Small tip to avoid perforation • Made of latex material • Longer length LA guide wire • 3lumensat proximal end. • USFDA /PMDAapproved
250BMV Balloon Catheter • Small tip to avoid perforation • Made of latex material • Longer length LA guide wire • 3lumensat proximal end. • CE-approved
251Mullin sheath with dilator • USFDA /PMDAapproved
252Mullin sheath with dilator • CE-approved
253Trans- septal needle. • USFDA /PMDAapproved
254Trans- septal needle. • CE-approved
255PTMC Balloon With all accessories (mullin sheath, coiled wire dilator, stylet trans-septal needle) • *Specially Designed balloon, perfectly shaped to for the mitral valve • *Short inflation/deflation cycle • *New small and soft tip • *Large size matrix • *Longer guide wire to increase safety in taller patients • USFDA/PMDA approved
256PTMC Balloon With all accessories (mullin sheath, coiled wire dilator, stylet trans-septal needle) • *Specially Designed balloon, perfectly shaped to for the mitral valve • *Short inflation/deflation cycle • *New small and soft tip • *Large size matrix • *Longer guide wire to increase safety in taller patients • CE- approved
257PTMC Balloon - • *Specially Designed balloon, perfectly shaped to for the mitral valve • *Short inflation/deflation cycle • *New small and soft tip • *Large size matrix • *Longer guide wire to increase safety in taller patients • USFDA/PMDA approved
258PTMC Balloon - • *Specially Designed balloon, perfectly shaped to for the mitral valve • *Short inflation/deflation cycle • *New small and soft tip • *Large size matrix • *Longer guide wire to increase safety in taller patients • CE- approved
259BRS Stent • Scaffold Mataerial- Bio resoreble PLLA (poly L-Lactide) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 mm • Scaffold Length- 16,19,24,29,32,40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 ug/mm2 • Polymer – Bioresorable PDLLA (Poly D, L-Lactide) Delivery System • Delivery System-Rapid exchange • Nominal Pressure (NP) – 9 atm • Rated Burst Pressure (RBP) -16 atm • Balloon Overhang - <1 mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F for linage delivery system • Radiopaque Markers – 2-platinum/Iridium • Usable Catheter Length-142 cm • Guide Catheter Compatibility-6F,)Min.1D0.070”/1.8mm) • Max. Guide wire-0.014” (0.36 mm) • USFDA /PMDAapproved
260BRS Stent • Scaffold Material- Bio resoreble PLLA (poly L-Lactide) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 mm • Scaffold Length- 16,19,24,29,32,40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 ug/mm2 • Polymer – Bioresorable PDLLA (Poly D, L-Lactide) Delivery System • Delivery System-Rapid exchange • Nominal Pressure (NP) – 9 atm • Rated Burst Pressure (RBP) -16 atm • Balloon Overhang - <1 mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F for linage delivery system • Radiopaque Markers – 2-platinum/Iridium • Usable Catheter Length-142 cm • Guide Catheter Compatibility-6F,)Min.1D0.070”/1.8mm) • Max. Guide wire-0.014” (0.36 mm) • CE-approved
261PTCA Inflation Device- • Efficient locking system to maintain high pressure • Rapid inflation and deflation • Clear barrel for easy visualization of de-bubbling • Luminescent analog pressure gauge (up to 30 atm) • Ergomatric and use friendly hand held design • Company’s name & logo has to be there on indeflator itself • USFDA /PMDAapproved
262PTCA Inflation Device- • Efficient locking system to maintain high pressure • Rapid inflation and deflation • Clear barrel for easy visualization of de-bubbling • Luminescent analog pressure gauge (up to 30 atm) • Ergomatric and use friendly hand held design • Company’s name & logo has to be there on indeflator itself • CE approved
263High Pressure PTCA inflation device analog pressure gauge upto 55 atm USFDA /PMDAapproved
264High Pressure PTCA inflation device analog pressure gauge upto 55 atm CE approved
265Haemostatic Y-Connector for PTCA-Push-pull Mechanism- • Should accommodate virtually all interventional devices • Luer connector at the guiding catheter end • Rotating adapter at the guiding catheter end • Should have bleed back safety mechanism • Stepwise control for open, semi open and closed position. • USFDA /PMDAapproved
266Haemostatic Y-Connector for PTCA-Push-pull Mechanism- • Should accommodate virtually all interventional devices • Luer connector at the guiding catheter end • Rotating adapter at the guiding catheter end • Should have bleed back safety mechanism • Stepwise control for open, semi open and closed position. • CE approved
267Haemostatic Y-Connector for PTCA-Rotational Mechanism- • Should accommodate virtually all interventional devices • Luer connector at the guiding catheter end • Rotating adapter at the guiding catheter end • Should have bleed back safety mechanism • USFDA approved
268Haemostatic Y-Connector for PTCA-Rotational Mechanism- • Should accommodate virtually all interventional devices • Luer connector at the guiding catheter end • Rotating adapter at the guiding catheter end • Should have bleed back safety mechanism • CE approved
269T.R. Band (Radial Artery Hemostasis Device)- Consists of two balloon specially designed for spot compression of the radial puncture site. USFDA /PMDAapproved
270T.R. Band (Radial Artery Hemostasis Device)- Consists of two balloon specially designed for spot compression of the radial puncture site. CE approved
271INTRAVASCULAR RETRIEVER-SNARE (‘AMPLATZ GOOSENESK’ TYPE)- Snare kit should include with all accessories like sheath etc. • A snare and its compatible sheath • Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop • Radiopaque marker at distal tip • Variable size of loop (5-35 mm) • USFDA/PMDA approved
272INTRAVASCULAR RETRIEVER-SNARE (‘AMPLATZ GOOSENESK’ TYPE)- Snare kit should include with all accessories like sheath etc. • A snare and its compatible sheath • Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop • Radiopaque marker at distal tip • Variable size of loop (5-35 mm) • CE approved
273INTRAVASCULAR RETRIEVER-Micro SNARE (‘AMPLATZ GOOSENESK’ TYPE)- Snare kit should include with all accessories like sheath etc. • A snare and its compatible sheath • Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop • Radiopaque marker at distal tip • Variable size of loop (2-4 mm) • USFDA/PMDA approved
274INTRAVASCULAR RETRIEVER-Micro SNARE (‘AMPLATZ GOOSENESK’ TYPE)- Snare kit should include with all accessories like sheath etc. • A snare and its compatible sheath • Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop • Radiopaque marker at distal tip • Variable size of loop (2-4 mm) • CE approved
275Guide extension catheter- • Stainless steel Hypotube, • polymer catheter segment 1 X 1 wire braiding hydrophilic coated with radical coller, • 0.57” inner Diameter, & 0.067” outer diameter • USFDA/PMDA approved
276Guide extension catheter- •Stainless steel Hypotube, • polymer catheter segment 1 X 1 wire braiding hydrophilic coated with radical coller, • 0.57” inner Diameter, & 0.067” outer diameter • CE approved
277Swan Ganz Catheter- • latex silicon balloon, • infusion capacity 1.5cc, • 7Fr sheath compatibility, • effective length 1100 mm • USFDA/PMDA approved
278Swan Ganz Catheter- • latex silicon balloon, • infusion capacity 1.5cc, • 7Fr sheath compatibility, • effective length 1100 mm • CE approved
279Hydrophilic angiography guide wire- • Single nitinol core alloy • Tungsten infused polyurethane jacket • 0.018” to .038” • Straight tip, angled tipand J tip • Regular length and exchange length • USFDA/PMDA- approved
280Hydrophilic angiography guide wire- • Single nitinol core alloy • Tungsten infused polyurethane jacket • 0.018” to .038” • Straight tip, angled tipand J tip • Regular length and exchange length • CE- approved
281Super stiff wire like amplatzer /Lunderquist • 0.018”, .035”,0.38” • Stiff core • Super stiff wire body • Atraumatic tip with gradual distal core taper • PTEF/Teflon coating • Flat coiled outer wire construction • Regular length and exchange length • USFDA/PMDA- approved
282Super stiff wire like amplatzer /Lunderquist • 0.018”, .035”,0.38” • Stiff core • Super stiff wire body • Atraumatic tip with gradual distal core taper • PTEF/Teflon coating • Flat coiled outer wire construction • Regular length and exchange length • CE- approved
283PTCA Guide wire • Core material Elastinite nitinol for excellent flexibility and durability. • Shaping ribbon for excellent for excellent shape retention. • Atraumatic tip load less than 0.65 gm. • Regular length, regular shaft support and floppy tip. • USFDA/PMDA approved
284PTCA Guide wire • Core material Elastinite nitinol for excellent flexibility and durability. • Shaping ribbon for excellent for excellent shape retention. • Atraumatic tip load less than 0.65 gm. • Regular length, regular shaft support and floppy tip. • CEapproved
285PTCA Guide wire • Regular workhorse guide wire with responsease, core grind technology, and 3.00 cm palladium-rhenium radio opaque distal tip. • Tip load >0.8gm. • Regular length 190cm and 300 cm. • USFDA/PMDA approved
286PTCA Guide wire • Regular workhorse guide wire with responsease, core grind technology, and 3.00 cm palladium-rhenium radio opaque distal tip. • Tip load >0.8gm. • Regular length 190cm and 300 cm. • CEapproved
287PTCA guide wire • Workhorse guide wire with triple spring 304 V stainless steel with NiTi distal core and cold working rotatory swagging tip. • Tip load 0.6gm. – 0.8gm. •Regular length 190cm and 300 cm. • USFDA/PMDA approved
288PTCA guide wire • Workhorse guide wire with triple spring 304 V stainless steel with NiTi distal core and cold working rotatory swagging tip. • Tip load 0.6gm. – 0.8gm. •Regular length 190cm and 300 cm. • CE approved
289PTCA guide wire for CTO • Latest CTO indicated guide wire with core material durasteel, hydrophilic coating and uncoated tip for better tactile feedback. • Tip load 11.0 gm. – 14.0 gm • Penetration power 167,224 kg/in2 • USFDA/PMDA approved
290PTCA guide wire for CTO • Latest CTO indicated guide wire with core material durasteel, hydrophilic coating and uncoated tip for better tactile feedback. • Tip load 11.0 gm. – 14.0 gm • Penetration power 167,224 kg/in2 • CEapproved
291PTCA Balloon • Semi compliant coronary balloon with slim seal technology on distal tip. • Crossing profile < 0.021” • Lesion entry profile < 0.017” • Nominal pressure 8 atm. And RBP 14 atm. • Available in diameter 1.20mm -4.00mm and length 6.00mm – 30.00mm. • Available in both Rx and OTW. • USFDA/PMDA approved.
292PTCA Balloon • Semi compliant coronary balloon with slim seal technology on distal tip. • Crossing profile < 0.021” • Lesion entry profile < 0.017” • Nominal pressure 8 atm. And RBP 14 atm. • Available in diameter 1.20mm -4.00mm and length 6.00mm – 30.00mm. • Available in both Rx and OTW. • CEapproved.
293PTCA Balloon • Non compliant coronary balloon with slim seal technology on distal tip. • Crossing profile < 0.021” • Lesion entry profile < 0.017” • Nominal pressure 8 atm. and RBP 14 atm. • Available in diameter 1.20mm -4.00mm and length 6.00mm – 30.00mm. • Available in both Rx and OTW. • USFDA/PMDA approved
294PTCA Balloon • Non compliant coronary balloon with slim seal technology on distal tip. • Crossing profile < 0.021” • Lesion entry profile < 0.017” • Nominal pressure 8 atm. and RBP 14 atm. • Available in diameter 1.20mm -4.00mm and length 6.00mm – 30.00mm. • Available in both Rx and OTW. • CEapproved
295PTCA Balloon • Non compliant coronary balloon with slim seal technology on distal tip. • Crossing profile < 0.021” • Lesion entry profile < 0.018” • Nominal pressure 8 atm. And RBP 14 atm. • Available in diameter 2.25mm -5.00mm and length 6.00mm – 30.00mm. • Available in both Rx and OTW. • USFDA/PMDA approved
296PTCA Balloon • Non compliant coronary balloon with slim seal technology on distal tip. • Crossing profile < 0.021” • Lesion entry profile < 0.018” • Nominal pressure 8 atm. And RBP 14 atm. • Available in diameter 2.25mm -5.00mm and length 6.00mm – 30.00mm. • Available in both Rx and OTW. • CEapproved
297PTCA Balloon • Semi compliant balloon with tri fold balloon design for good rewrap and laser bond technology on distal tip. • Crossing profile < 0.021” • Tip entry profile < 0.017” • Available in diameter 1.20 mm to 4.0 mm and length 6.00 mm to 30.00 mm. • USFDA/PMDA approved.
298PTCA Balloon • Semi compliant balloon with tri fold balloon design for good rewrap and laser bond technology on distal tip. • Crossing profile < 0.021” • Tip entry profile < 0.017” • Available in diameter 1.20 mm to 4.0 mm and length 6.00 mm to 30.00 mm. • CE Approved.
299PTCA Balloon • Non compliant balloon with tri fold balloon design for good rewrap and laser bond technology on distal tip. • Crossing profile < 0.021” • Tip entry profile < 0.018” • Available in diameter 2.00 mm to 4.50 mm and length 8.00 mm to 25.00 mm. • USFDA/PMDA approved
300PTCA Balloon • Non compliant balloon with tri fold balloon design for good rewrap and laser bond technology on distal tip. • Crossing profile < 0.021” • Tip entry profile < 0.018” • Available in diameter 2.00 mm to 4.50 mm and length 8.00 mm to 25.00 mm. • CEApproved
301FFR Pressure Wire • Should be 0.014” guide wire. • System should work both wired and wireless radio using frequency hopping spread spectrum to ensure secure radio connection with Pressure Wire. • Should be compatible with available QUANTIEN FFR Measurement System. • USFDA/PMDA approved
302FFR Pressure Wire • Should be 0.014” guide wire. • System should work both wired and wireless radio using frequency hopping spread spectrum to ensure secure radio connection with Pressure Wire. • Should be compatible with available QUANTIEN FFR Measurement System. • CE Approved
303OCT Catheter • The imaging catheter should be able to emit near infra red light to produce high resolution real time image. • Catheter should be compatible with 0.014” guide wire. • Should be compatible with available Optis Integrated Next OCT System • USFDA/PMDA Approved
304OCT Catheter • The imaging catheter should be able to emit near infra red light to produce high resolution real time image. • Catheter should be compatible with 0.014” guide wire. • Should be compatible with available Optis Integrated Next OCT System • CE Approved
305Haemostatic Y-Connector for PTCA-Push-pull Mechanism- • Should accommodate virtually all interventional devices • Should have bleed back control valve with twin seals. • Bleed back seal and clamp seal permits high pressure injection up to 400 psi. • Push pull knob for single operator use and complete homeostasis. • USFDA/PMD Approved
306Haemostatic Y-Connector for PTCA-Push-pull Mechanism- • Should accommodate virtually all interventional devices • Should have bleed back control valve with twin seals. • Bleed back seal and clamp seal permits high pressure injection up to 400 psi. • Push pull knob for single operator use and complete homeostasis. • CE approved
307ORBITAL ATHERECTOMY- • Single 6F 1.25mm Diamond Coated Crown 6.5mm away from tip for treating vessels 2.5mm to 4.0mm. • It should provide Bi-directional Sanding & Pulsatile Forces in Orbital Motion Creates Micro Fractures to modify Deep Calcium. • The device should comes with a combo of 1each of Viper Wire made up Nitinol having 0.014 inch Tip Diameter & length 325cm along with 1each of Viper Slide Lubricant 100ml capacity. • US FDA/PMDA Approved.
308ORBITAL ATHERECTOMY- • Single 6F 1.25mm Diamond Coated Crown 6.5mm away from tip for treating vessels 2.5mm to 4.0mm. • It should provide Bi-directional Sanding & Pulsatile Forces in Orbital Motion Creates Micro Fractures to modify Deep Calcium. • The device should comes with a combo of 1each of Viper Wire made up Nitinol having 0.014 inch Tip Diameter & length 325cm along with 1each of Viper Slide Lubricant 100ml capacity. • CE- Approved.
309CONSOLE for ORBITAL ATHERECTOMY- • System shouldbe convenient Two-Speed Controls 80,000 RPM & 1,20,000 RPM Per Minute. • System should be small electric operated & fix on the side of the Cath Lab Tabel or Fix on the IV stand available in the Cath Lab. • System should be electric-powered handle allows two-minute set up and provides efficient torque transfer to the shaft and crown. • System should be Glide assist feature for easier tracking and removal and smoother repositioning of the device. • USFDA/PMDA approved
310CONSOLE for ORBITAL ATHERECTOMY- • System shouldbe convenient Two-Speed Controls 80,000 RPM & 1,20,000 RPM Per Minute. • System should be small electric operated & fix on the side of the Cath Lab Tabel or Fix on the IV stand available in the Cath Lab. • System should be electric-powered handle allows two-minute set up and provides efficient torque transfer to the shaft and crown. • System should be Glide assist feature for easier tracking and removal and smoother repositioning of the device. • CE- approved
311Peripheral Mechanical Thrombectomy- PE specifications : Catheter : Large lumen aspiration with multiple material transitions for advanced tracking technology , with atraumatic tip for circumferential aspiration. Catheter size : available in 8F(2.67mm OD) with two working lengths – 85 cm and 115 cm Catheter type : straight tip and extra torque ( for a 360 degree aspiration) Separator : proprietary separator technology for easy and quick aspiration, with150 cm length and distal OD of 1.83 mm.
312Peripheral Mechanical Thrombectomy ALI & DVT specifications : Catheter : Large lumen aspiration with multiple material transitions for advanced tracking technology , with atraumatic tip for circumferential aspiration. Catheter size : available in 6F(2.0mm OD) with working length – 135 cm Catheter type : straight tip and extra torque ( for a 360 degree aspiration) Separator : proprietary separator technology for easy and quick aspiration, with175 cm length and distal OD of 1.40 mm. Peripheral Mechanical Thrombectomy- STEMI specifications: Catheter: Stainless steel hypotube at the proximal end,designed to enhance deliverability to the desired vesselwith optimal visualization and placement. Catheter size : 6 F Catheter type : Low crossing profile of 1.75mm with an ID of .044”. Separator : proprietary separator technology for easy and quick aspiration, with 200 cm length and distal OD of .89 mm.
313Aspiration Thrombectomy Catheter • Available in Size 6F, 7F Both, Must have entry profile 0.019 inches • Must Have 1.30 mm square suction area • Braided polyamide elastomer shaft, stainless steel wire braiding and Guide wire type Stylet, • 6.0mm tip length for making aspiration inlet to come closer to the target thrombus and 10cm-length depth. • Must Have Distal 40 cm Hydrophilic coating. • USFDA/PMDA Approved
314Aspiration Thrombectomy Catheter • Available in Size 6F, 7F Both, Must have entry profile 0.019 inches • Must Have 1.30 mm square suction area • Braided polyamide elastomer shaft, stainless steel wire braiding and Guide wire type Stylet, • 6.0mm tip length for making aspiration inlet to come closer to the target thrombus and 10cm-length depth. • Must Have Distal 40 cm Hydrophilic coating. • CE Approved
315Endomyocardial Biopsy Forceps – • Stainless Steel or FEP coated • Two stainless steel symmetrical hinged cutting jaws • Three-ring handle & Rotational Central ring. • Straight, Pre-Curved or Maxi-Curved configurations - Formable and Non-Formable options • 1.5mm, 1.8mm, 2.2mm, 2.4mm • USFDA/PMDA Approved
316Endomyocardial Biopsy Forceps – • Stainless Steel or FEP coated • Two stainless steel symmetrical hinged cutting jaws • Three-ring handle & Rotational Central ring. • Straight, Pre-Curved or Maxi-Curved configurations - Formable and Non-Formable options • 1.5mm, 1.8mm, 2.2mm, 2.4mm • CE Approved
317• Valve-TAVI • Self-expanding frame, Supra-annular valve design, Bovine Pericardial Valve • Proprietary Anti-calcification tissue treatment • Extended internal sealing skirt • Two rows of Radio-opaque markers on valve frame for implantation guidance • Varying radial force frame – optimal forces at 3 parts of the frame • Post dilatation limits of valve frame equal to approved annulus diameter limit • Coronary arteries access - Cell size of = 15 French in mid-frame • Available in three sizes of 22, 26, and 30 mm Delivery Catheter (system) • Non-Braided Transparent Capsule & Flexible Shaft for ease of deliverability • Unique color-coded indicators for deployment guidance • 14 Fr, & 15Fr
318Balloon expandable transcatheter aortic valve replacement system with all standard accessories for implantation should be available in standard, intermediate sizes and XL sizes should be quoted with all accessories (delivery system, dilatation balloon catheter and introducer sheath) CE- approved
319Vascular Closure Device • Device 6 Fr, 8 fr • Device Length 205 + 10 mm • Device Effective Length 155 + 10 • Device degradation period 90 days • Anchor Material Poly (D,L-lactide-co-glycolide) • Device Material PDLG anchor, poly glycolic acid (PGA) suture and bovine type-I collagen plug • Device size compatibility- 6 fr device compatible with 6 fr and 7 fr introducer sheath • 8 Fr device device compatible with 8 fr and 9 fr introducer sheath • USFDA/PMDA -approved
320Vascular Closure Device • Device 6 Fr, 8 fr • Device Length 205 + 10 mm • Device Effective Length 155 + 10 • Device degradation period 90 days • Anchor Material Poly (D,L-lactide-co-glycolide) • Device Material PDLG anchor, poly glycolic acid (PGA) suture and bovine type-I collagen plug • Device size compatibility- 6 fr device compatible with 6 fr and 7 fr introducer sheath • 8 Fr device device compatible with 8 fr and 9 fr introducer sheath • CE-approved
321Rotablator Burr • Size 1.25 mm to 1.75 mm • Compatible to existing machine at RNT MC, Udaipur • USFDA/PMDA approved
322Rotablator Burr • Size 1.25 mm to 1.75 mm • Compatible to existing machine at RNT MC, Udaipur • CEapproved
323Rotablator (Rota link plus-Burr & advancer) • Size 1.25 mm to 1.75 mm • Compatible to existing machine at RNT MC, Udaipur • USFDA/PMDA approved
324Rotablator (Rota link plus-Burr & advancer) • Size 1.25 mm to 1.75 mm • Compatible to existing machine at RNT MC, Udaipur • CE approved
325IVUS Catheters • Compatible to existing machine at RNT MC, Udaipur • USFDA/PMDA approved
326OCT Catheters • Compatible to existing machine at RNT MC, Udaipur • USFDA/PMDA approved
327OCT Catheters • Compatible to existing machine at RNT MC, Udaipur • CE approved
328Special PTCA Balloon –Non Complaint Coronary balloon with multilayer • cross flex balloon technology • round tip with lesion entry profile of 0.018” • diameter 1.5mm-5mm and •lengths in 6mm- 25mm • skive technology on mid shaft of dilation catheter • USFDA/PMDA approved
329Special PTCA Balloon –Non Complaint Coronary balloon with multilayer • cross flex balloon technology • round tip with lesion entry profile of 0.018” • diameter 1.5mm-5mm and •lengths in 6mm- 25mm • skive technology on mid shaft of dilation catheter • CE approved
Disclaimer :