Public Administrative Department Local Bodies Closing in 0 days TDR #42566995

Tender For Yearly Maintenance And Repair Of Street Lights In Indapur Municipal Council On Annual Contractual Basis, Erection Of New Street Lights And Other Ancillary Works As Required

Issued by Local Bodies · indapur, Maharashtra
Tender Value
21 Lakhs
Estimated cost
Bid Submission
04 Mar 2024
0 days left
EMD
21000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
indapur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Yearly Maintenance And Repair Of Street Lights In Indapur Municipal Council On Annual Contractual Basis, Erection Of New Street Lights And Other Ancillary Works As Required- 1 Supplying & Erecting Mains With 2X10 Sq.Mmf.R Copperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw 2 Supplying & Erecting Mains With 2X6 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw 3 Supplying & Erecting Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw 4 Supplying And Erecting Mains With Wp 2 X 6 Sq. Mm. 1100 V Grade Aluminiumpvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swgg.I. Binding Wire. 5 Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminiumpvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swgg.I. Binding Wire 6 Supplyinganderectingisi Mark G.I. Pipepole ‘B’ Grade80 Mm Dia 6 M Longwith Pole Cap, Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Gip 7 Supplying And Erecting Rolled Steel Joist ( Girder ) Pole 125 X 70 Mm ( 13.3 Kg / M ) With Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Rsj 8 Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm Diawith 4.5 X 3.65 X 3.25 Mm Thickness ( 5+2+2 M ) Length Respectively And Total9 M Long With Pole Cap, Base Plate In Provided Foundation ( Weight 113 Kg ) As Perspecification No 9 Providing & Erecting 7 M High ( Clear Height ) Galvanised Octagonal Pole Withfoundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Providedfoundation As Per Specification No. Oh-Pl / Opl 10 Providing & Erecting 9 M High ( Clear Height ) Galvanised Octagonal Pole Withfoundation Bolts Having Bottom Of 155 Mm A / F, Top 70 Mm A / F On Providedfoundation As Per Specification No. Oh-Pl / Opl 11 Providing And Erecting Galvanised 1000Mm Single Arm Sword Type Bracket With Frp Domeand Ball As Per Specification No. Oh-Pl / Pbkt 12 Providing And Erecting Galvanised 1000Mm Double Arm Sword Type Bracket With Frp Domeand Ball As Per Specification No. Oh-Pl / Pbkt 13 Supplying & Erecting Ms Pole Bracket For Guarding / Lt Oh Line, Fabricatedfrom Angle Iron 50X50x6mm And 1100Mm Long For Necessary Nos. Ofprovided Insulators, And Erecting On Pole With 50X6mm Clamp Complete As Perspecification No. Oh -Pl / Bkt 14 Supplying And Erecting G.I. Pipe ‘C’ Class Erw 25 Mm Dia With Necessary Fittings Complete As Per Specification No. 15 Supplying And Erecting G.I. Pipe ‘C’ Class Erw 50 Mm Dia With Necessaryfittings Complet 16 Supplyinganderectingpole Clamp Madefrom50 X 6 Mmms Flat For Pole Or Pipe, Postcompleteerected With 15 Mm Bolts And Nuts, Complete Duly Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint. 17 Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results Asper Specification No. Ea-Ep 18 Providingpipetype Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rodcomplete With All Materials As Per Specification No. Ea-Ep 19 Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm With Funnel With A Wire Mesh For Watering And Brick Masonry Block C.L. Cover Complete With All Materials, Testing & Recording The Results As Per 20 Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( Above 6 M To 9 M Poles ) 21 Making M- 20 Grade Reinforced Cement Concrete Foundation By Consideringthe Safe Soil Bearing Capacity At Site As 10 T / Sq.M At 1.5 M Depth Including Supplyof Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Oftemplate, Duly Plastered As Per Design Complete ( For 9M & 10M High Octagonal / Conical Gi Pole ) 22 Making M- 20 Cement Concrete Foundation By Considering The Safe Soilbearing Capacity At Site As 10 T / Sq. M At 2 M Depth Including Excavation And Fixingprovided Nut Bolts With The Help Of Template, Duly Plastered As Per Designcomplete ( For 12.5 M Raising Lowering High Mast ) 23 Painting Of Steel Tubular / Rail / Rsj Pole Above 6.0 M Length Along Withstreet Light Pole Brackets, Clamps Etc By Scrapping The Existing Paint Completeas Per Specification No Cw -Ptg / Ptp. 24 Supplying, Erecting & Marking Dpmcb 6A To 32A, C-Series With Rated Short -Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Perspecification No. Sw-Swr / Mcb 25 Supplying, Erecting & Marking Dpmcb 6 A To 32 A B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 26 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 63Aerected On Polished Wooden Block. 27 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 100Aerected On Polished Wooden Block. 28 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 200Aerected On Polished Wooden Block 29 Supplying, Erecting & Marking Tpmcb 40A To 63A, With Rated Short - Circuitbreaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specificationno. Sw-Swr / Mcb 30 Supplying, Erecting & Marking Fpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 31 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 32 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 33 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductorcomplete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 34 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 35 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 35 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 70 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 36 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3 Core 4 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Cu 37 Supplying & Erecting D.O.L Starter Suitable For 415 V, 3 Phase 50 Cycles With Novolt Coil And Overload Element With Necessary Materials And Connected To Supplyup To 7.5 H.P. 38 Supplying & Erecting Fully Automatic Star / Delta Starter Suitable For 12.5 H.P To 15 H.P. For 3 Phase Squirrel Cage Motor Totally Enclosed With Overload And No Volt Relay Complete Erected On Provided Angle Iron Frame 39 Supplying & Erecting Frp Box Of Size 300Mm X 200Mm X 125 Mm, 2.7 Mmthick Complete On Pole / Wall As Per Specification No. Cb-Sb 40 Supplying & Erecting Frp Box Of Size 250Mm X 200Mm X 100 Mm, 2.7 Mm Thick Complete On Pole / Wall As Per Specification No. Cb-Sb 41 Supplying Andlaying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 90 Mmoutside Dia. Double Wall Corrugatedpipes ( Dwc ) Ofhdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. 42 Supplying & Erecting Crimping Type Copper Lugs For Cable 25 Sq. Mm. Complete As Per Specification No. Cb-Cl / Cu 43 Supplying & Erecting Crimping Type Copper Lugs For Cable120 Sq. Mm. Completeas Per Specification No. Cb-Cl / Cu 44 Supplying And Erecting Metal Work In Crca Sheet Including Iron Work For Supports With Fabrication Of Boxes, Panel Boards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment And Duly Powder Coated Or Painted With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete. ( Meter Pannel Box ) 45 Point Wiring For Light / Bell Hybrid Type ( Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls ) In Min 20 Mm Pvc Conduit / Casing N Capping With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wgpw / Hw 46 Point Wiring For Ceiling Fan ( Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls ) In Min 20 Mm Pvc Conduit / Casing Ncapping With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories 47 Supplying And Erecting Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Anyother Places. As Per Specification No: Wg-Ma / Bw 48 Supplying And Erecting Modular Type ( Two Module ) Electronic Step Regulator For Fan, Duly Erected On Provided Plate And Box With Wiring Connections Complete. 49 Supplying And Erecting Regular / Standard Model Ceiling Fan Of 1400Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 50 Supplying And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 Rpm. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Speed Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 51 Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E’ Class Insulation. 52 Supplying And Erecting Integrated Led Street Light Fitting 23 To 25W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 2300 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3Years Warranty As Per Specification No Fg-Odf / Fls2. 53 Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 54 Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08class Having Single Piece Pressure Die-Cast Aluminium Housing, Having Systemlumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuiltsurge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Drivercomplete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 55 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 56 Supplying And Erecting Integrated Led Flood Light Fitting Max. 120W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min.14500 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 57 Erecting Departmentally Supplied Led Street Light / Flood Light Fitting Above80 To 150W . 58 Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B’ Classg.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Diaduly Welded With Provided Leads As Per Specification No. Fg-Bkt / Bpc 59 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W-75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 60 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 151W-200W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 61 Supplying And Erecting T8 Fluorescent Tube Day Light 600Mm, 18 W 62 Supplying & Erecting Ready To Use Retrofit T8 Led 18 / 20 Tube Light With Polycarbonate Body, Heat Sink, Integrated Hf Electronic Driver Complete &Compatible To T8 / T12 Led Luminaire By Disconnecting Starter & Ballast If Necessary. 63 Supplying And Erecting Flush Type Shockproof Plug Socket 6A & 16A ( 6 Pin ) With 16A Switch Combined With Indicator Lamp And Fuse With Gang Box Onwooden Board 64 Supplying And Erecting Modular Type 32A, Dp Key Tag Switch With Key Tag, Duly Erected On Provided Plate And Box With Wiring Connections Complete 65 Supplying & Erecting 18W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base 66 Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 700Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs. Based Oninsulated Gate Bipolar Transistor ( Igbt ) Technology Complete As Perspecification No. Ap-Inv 67 Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 1400 To 1600Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs.Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Complete As Perspecification No. Ap-Inv 68 Supplying, Erecting, Testing And Commissioning Of Single Phase Input & 1 Phaseoutput 1 Kva Capacity Online Pure Sine Wave Ups, With Backup Time Of .......Hrs. Pwm & Igbt Based, With 0.8 To Unity Output Pf Complete With Allprotections As Per Specification No. Ap-Ups 69 Supplying And Erecting 12V / 200Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete 70 Supplying And Erecting 12V / 150Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete. 71 Providing Servicing Of 1 / 1.5 / 2 / 3 Tr Capacity Split / Window Airconditioning Unit With All Necessary Material. Job Includes Checking Ofperformance Of Unit, Cleaning Of Filters Of Indoor Unit, Cleaning Of Outdoor Unitwith Blower, Checking Of Electrical Connection Of Indoor As Well As Outdoor Unitcomplete And Submitting Report To Engineer Incharge. 72 Providing Annual Comprehensive Maintenance Contract For 1.5Trsplit / Window Air Conditioning Unit Complete As Per Terms And Conditions. Jobincludes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheetmetal Work And Plastic Material 73 Providing Brazing Pipes And Checking Leakages In The Split / Window Unitduly With Dry Nitrogen Pressure, Complete. 74 Providing Replacement Of Unserviceable Pcb For Ac Unit Upto 3Tr Capacity 75 Supplying And Erecting Quartz Electronic Time Switch Having 24 Hour Dial Towork On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteriesto Run The Time Switch On Failure Of Supply Having Switch Contact Rating Up To 16Ato Use Independently Or In Conjunction With Contactor 76 Supplying And Erecting Four Pole Power Contactor 430 V, 40 A For Time Switchcomplete Erected On Provided Wooden Block / Box, With Necessary Materials 77 Supplying And Erecting Programmable Digital Almanac Timer Microcontrollerbased With Real Time Clock To Operate On Derived Switching “On” And Switching“Off” Street Light As Per Daily Sunset And Sunrise Respectively Automaticallyhaving 4 Digit Led Continuous Time Display, Relay Output 230 V / 10A With 10Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Differentcapacity Contactors Timer Erected In Provided M.S. Box 78 Supplying And Erecting Static Energy Meter With 240V 50 Hz. Ac Supply 10To 60 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, ( Measuring Anddisplay Kwh, Kvah, V, I, Pf, Frequency, Kw, Kva, Six Months History Ofenergy & Md In Kw & Kva ) With Transparent Hinge Type Box Completeerected On Polished Teak Wood Board Duly Wired With Required Size Ofweather Proof Pvc Wires Duly Tested By Electric Supply Company 79 Supplying & Erecting Crimping Type Aluminium Lugs For Cable 240 Sq Mmcomplete As Per Specification No. Cb-Cl / Al 80 Supplying And Erecting All Aluminium Stranded Conductors 7 / 2.21 Mm.Complete. ( Gnat ) ( 73.77Kg / Km ) As Per Specification No. Oh-Con / Aac 81 Supplying And Erecting 3 Phase 4 Core 35 Sq.Mm. ( 3X35+1X25 ) Aerial Bunchedaluminium Cable Along With Necessary Accessories For Lt Distribution Onprovided Lt Pole As Per Specification No. Oh-Cbl / Abc 82 Supplying And Erecting G.I. Stay Set For Poles, Including Loop Insulators Atinaccessible Height With Anchor Plate 300X300x6mm., Straining Screws, G.L. Staywire 7 / 10 Swg, G.L. Stay Rod 20Mmx1.8M Length And Pole Clamps Duly Erected Inprovided Cement Concrete Foundation Complete 83 Dismantling The Existing Pole Above 6 M Height With Brackets, Clamps, Insulators, Stay From The C.C. Foundation And Making The Site Clear By Refilling Thepits With Excavated Materials And Bringing It To The Ground Level. 84 Supplying And Erecting Crca Powder Coated Corridor / Passage Light Ledfitting ( 4 Feet ) Max. 50W With High Transitivity Diffuser With System Lumensoutput Of Min. 6000 Lumens , Min. Efficacy Of 120 Lumen / W, Cri>80, Cctupto 6500K, Beam Angle Of 120 Deg., Ripple<5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs.At L70b50, Including Driver, With End Caps On Provided Pvc Block / Woodenboard With 3 Years Warranty. 85 Supplying And Erecting Electronic Type Cordless Call Bell Erected On T.W.Board Having Portable Bell Push Working On 9V D.C. Battery And ( Effectiverange Upto 45 Meter ) Bell On 250 V A.C. Supply. 86 Supplying And Erecting Electronic Type Driver For Indoor Led Upto 24W Fixturessuitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 87 Erecting The Departmentally Supplied Wp Led Street Light / Flood Light Fittingupto 80W. 88 Erecting Departmentally Supplied Led Street Light / Flood Light Fitting Above80 To 150W . 89 Dismantling The Existing W.T. Fluorescent Fitting / S.V. / M.V. / M.H. Lamp / Led Fitting From Pole With Brackets Complete. 90 Erection Of Departmentally Supplied 4Ft / 2Ft Led Fitting On Pvc Blockconnected With Necessary Leads Complete 91 Supplying And Erecting Integrated Led Street Light Fitting 18 To 22W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 1800 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fgodf / Fls2. 92 Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 93 Supplying And Erecting Integrated Led Street Light Fitting 60W Ip65 & Ik08class Having Single Piece Pressure Die-Cast Aluminium Housing, Having Systemlumens Output Of Min. 6600 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuiltsurge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Drivercomplete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 94 Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08class Having Single Piece Pressure Die-Cast Aluminium Housing, Having Systemlumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuiltsurge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Drivercomplete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 95 Supplying And Erecting Integrated Led Street Light Fitting 100-110W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 11000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 96 Supplying And Erecting Integrated Led Flood Light Fitting Max. 100W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min. 12000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 97 Supplying And Erecting Gate / Garden Light Fitting With 200Mm Dia. Glass Bowlsuitable For Upto 12W Led Lamp On Provided Pipe As Per Specification No. Fgodf / Glt 98 Supplying And Erecting Street Light Bracket For Erection Of Single Fitting Madefrom 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fg-Bkt / Bpc 99 Supplying And Erecting Street Light Bracket For Erection Of Double Fittingmade From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Capof 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fgbkt / Bpc 100 Supplying And Erecting Street Light Bracket For Erection Of Single Fitting Ontubular Welded Pole With 40 Mm. Dia 1.0 M. Length “B” Class G.I .Pipe Alongwith Pole Cap Of 125Mm Dia 600 Mm Long Duly Welded As Per Specification No.Fg-Bkt / Bpc 101 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto25w Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 102 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 26W-45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 103 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W-75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 104 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 105 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 76W-100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 106 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 101W-150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 107 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 108 Supplying And Erecting Programmable Digital Almanac Timer Microcontrollerbased With Real Time Clock To Operate On Derived Switching “On” And Switching“Off” Street Light As Per Daily Sunset And Sunrise Respectively Automaticallyhaving 4 Digit Led Continuous Time Display, Relay Output 230 V / 10A With 10Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Differentcapacity Contactors Timer Erected In Provided M.S. Box 109 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 76W-100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 110 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 101W-150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 111 Supplying & Erecting 18W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base 112 Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 1400 To 1600Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs.Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Complete As Perspecification No. Ap-Inv 113 Providing & Erecting 3 Pole Mccb, 415 V, 100A, Rated Short-Circuit Breakingcapacity 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Fixedmagnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Tripalarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstandcapacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specificationno. Sw-Swr / Mccb 114 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 32Aerected On Polished Wooden Block 115 Supplying & Erecting Hrc Fuse Cartridge 415V, 400A 116 Supplying And Erecting 3 Phase 4 Core 35 Sq.Mm. ( 3X35+1X25 ) Aerial Bunchedaluminium Cable Along With Necessary Accessories For Lt Distribution Onprovided Lt Pole As Per Specification No. Oh-Cbl / Abc 117 Supplying And Erecting G.I. Stay Set For Poles, Including Loop Insulators Atinaccessible Height With Anchor Plate 300X300x6mm., Straining Screws, G.L. Staywire 7 / 10 Swg, G.L. Stay Rod 20Mmx1.8M Length And Pole Clamps Duly Erected Inprovided Cement Concrete Foundation Complete. 118 Dismantling The Existing Pole Above 6 M Height With Brackets, Clamps, Insulators, Stay From The C.C. Foundation And Making The Site Clear By Refilling Thepits With Excavated Materials And Bringing It To The Ground Level. 119 Supplying And Erecting Of Isi Mark Insulation Tape 120 Supplying And Erecting Of Isi Mark Nutbolts 121 Supplying And Erecting Of Isi Mark Tester 122 Supplying And Erecting Of Isi Mark Led Zero Bulb 123 Supplying And Erecting Of Isi Mark Led Zero Bulb Holder 124 Supplying And Erecting Fault Clearing On Street Light Conductor 125 Supplying And Erecting Of Ac Servicing 126 Supplying And Erecting Of Filter Servicing 127 Supplying And Erecting Of Batery Servicing With Water Change 128 Supplying And Erecting Of Ro Membrane For Filter 129 Supplying And Erecting Isi Mark Extension Box

BOQ

Name of Work:??????? ????????????? ???????? ??????????? ?????? ? ???????? ??????? ???????? ???????? ???? ???? ???????????? ???? ?????? ?????? ? ??? ???????? ???? ????.(?? 2024-25)(As per CSR 2022-23)
Sl. No. Item Description
1Supplying & erecting mains with 2x10 sq.mmF.R copperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
2Supplying & erecting mains with 2x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
3Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
4Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V grade aluminiumPVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWGcomplete erected with required size of porcelain reel insulators and 16 SWGG.I. binding wire.
5Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminiumPVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWGcomplete erected with required size of porcelain reel insulators and 16 SWGG.I. binding wire
6SupplyinganderectingISI mark G.I. pipepole ‘B’ grade80 mm dia 6 m longwith pole cap, base plate in provided foundation as per specification no. OH-PL/GIP
7Supplying and erecting rolled steel joist (girder) pole 125 x 70 mm (13.3 kg/m)with base plate in provided foundation as per specification no. OH-PL/RSJ
8Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm diawith 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total9 m long with pole cap, base plate in provided foundation (weight 113 kg) as perspecification no
9Providing & erecting 7 m high (clear height) galvanised octagonal pole withfoundation bolts having bottom of 130 mm A/F, top 70 mm A/F on providedfoundation as per specification no. OH-PL/OPL
10Providing & erecting 9 m high (clear height) galvanised octagonal pole withfoundation bolts having bottom of 155 mm A/F, top 70 mm A/F on providedfoundation as per specification no. OH-PL/OPL
11Providing and erecting galvanised 1000mm single arm sword type bracket with FRP domeand ball as per specification no. OH-PL/PBKT
12Providing and erecting galvanised 1000mm double arm sword type bracket with FRP domeand ball as per specification no. OH-PL/PBKT
13Supplying & erecting MS pole bracket for guarding/LT OH line, fabricatedfrom angle iron 50x50x6mm and 1100mm long for necessary nos. ofprovided insulators, and erecting on pole with 50x6mm clamp complete as perspecification no. OH -PL/BKT
14Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no.
15Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessaryfittings complet
16Supplyinganderectingpole clamp madefrom50 x 6 mmMS flat for pole or pipe, postcompleteerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint.
17Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
18Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP
19Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per
20Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
21Making M- 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supplyof steel, concrete, excavation and fixing provided nut bolts with the help oftemplate, duly plastered as per design complete (for 9m & 10m high octagonal/conical GI pole)
22Making M- 20 cement concrete foundation by considering the safe soilbearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixingprovided nut bolts with the help of template, duly plastered as per designcomplete (for 12.5 m raising lowering high mast)
23Painting of steel tubular / rail / RSJ pole above 6.0 m length along withstreet light pole brackets, clamps etc by scrapping the existing paint completeas per specification no CW -PTG/PTP.
24Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB
25Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
26Supplying and erecting porcelain base iron clad cut out HC type 415V, 63Aerected on polished wooden block.
27Supplying and erecting porcelain base iron clad cut out HC type 415V, 100Aerected on polished wooden block.
28Supplying and erecting porcelain base iron clad cut out HC type 415V, 200Aerected on polished wooden block
29Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB
30Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
31Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
32Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
33Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
34Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
35Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
36Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
37Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with novolt coil and overload element with necessary materials and connected to supplyup to 7.5 H.P.
38Supplying & erecting Fully Automatic Star/delta starter suitable for 12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame
39Supplying & erecting FRP box of size 300mm x 200mm x 125 mm, 2.7 mmthick complete on pole/wall as per specification No. CB-SB
40Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
41Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 90 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.
42Supplying & erecting crimping type copper lugs for cable 25 sq. mm. complete as per specification no. CB-CL/CU
43Supplying & erecting crimping type copper lugs for cable120 sq. mm. completeas per specification no. CB-CL/CU
44Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.(Meter pannel box)
45Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
46Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing ncapping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch,earthing and required accessories
47Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places. as per specification No: WG-MA/BW
48Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
49Supplying and erecting regular/ standard model ceiling fan of 1400mm. Sweep complete erected in position as per specification no. FG-FN/CF
50Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation
51Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
52Supplying and erecting integrated LED street light fitting 23 to 25W IP65 &IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W,CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, includingdriver complete with 3Years warranty as per specification No FG-ODF/FLS2.
53Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W,CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, includingdriver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
54Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including drivercomplete with 3 Years warranty as per specification No FG-ODF/FLS2.
55Supplying and erecting integrated LED flood light fitting Max. 70W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
56Supplying and erecting integrated LED flood light fitting Max. 120W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2
57Erecting departmentally supplied LED street light/ flood light fitting above80 to 150W .
58Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ classG.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm diaduly welded with provided leads as per specification no. FG-BKT/BPC
59Supplying and erecting electronic type Driver for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
60Supplying and erecting electronic type Driver for Outdoor LED Fittings 151W-200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
61Supplying and erecting T8 Fluorescent tube day light 600mm, 18 W
62Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete &compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary.
63Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin)with 16A switch combined with indicator lamp and fuse with gang box onwooden board
64Supplying and erecting modular type 32A, DP key tag switch with key tag,duly erected on provided plate and box with wiring connections complete
65Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 / E-27 base
66Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz,700VA digital pure sine wave inverter with backup time of ........ hrs. based onInsulated Gate Bipolar Transistor (IGBT) technology complete as perspecification no. AP-INV
67Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz,1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs.based on Insulated Gate Bipolar Transistor (IGBT) technology complete as perspecification no. AP-INV
68Supplying, erecting, testing and commissioning of single phase input & 1 phaseoutput 1 kVA capacity online pure sine wave UPS, with backup time of .......hrs. PWM & IGBT based, with 0.8 to unity output pf complete with allprotections as per specification no. AP-UPS
69Supplying and erecting 12V/200Ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete
70Supplying and erecting 12V/150Ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete.
71Providing servicing of 1/1.5/2/3 TR capacity split/window airconditioning unit with all necessary material. job includes checking ofperformance of unit, cleaning of filters of indoor unit, cleaning of outdoor unitwith blower, checking of electrical connection of indoor as well as outdoor unitcomplete and submitting report to Engineer incharge.
72Providing annual comprehensive maintenance contract for 1.5TRsplit/window air conditioning unit complete as per terms and conditions. Jobincludes 1) quarterly servicing 2) on call repair 3) replacement of all spares within24 hours 4) sending standby manpower for VIP movement. The job exclude sheetmetal work and plastic material
73Providing brazing pipes and checking leakages in the split/window unitduly with dry nitrogen pressure, complete.
74Providing replacement of unserviceable PCB for AC unit upto 3TR capacity
75Supplying and erecting quartz electronic time switch having 24 hour dial towork on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteriesto run the time switch on failure of supply having switch contact rating up to 16Ato use independently or in conjunction with contactor
76Supplying and erecting four pole power contactor 430 V, 40 A for time switchcomplete erected on provided wooden block/ box, with necessary materials
77Supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “ON” and switching“OFF” street light as per daily sunset and sunrise respectively automaticallyhaving 4 digit LED continuous time display, relay output 230 V / 10A with 10hrs. battery backup and manual over drive facility capable to drive differentcapacity contactors timer erected in provided M.S. box
78Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring anddisplay kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history ofEnergy & MD in kW & kVA ) with transparent hinge type box completeerected on polished teak wood board duly wired with required size ofweather proof PVC wires duly tested by electric supply company
79Supplying & erecting crimping type aluminium lugs for cable 240 sq mmcomplete as per specification No. CB-CL/AL
80Supplying and erecting all aluminium stranded conductors 7/2.21 mm.complete. (Gnat) (73.77kg/km) as per specification No. OH-CON/AAC
81Supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) Aerial bunchedaluminium cable along with necessary accessories for LT distribution onprovided LT pole as per specification no. OH-CBL/ABC
82Supplying and erecting G.I. stay set for poles, including loop insulators atinaccessible height with anchor plate 300x300x6mm., straining screws, G.l. staywire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected inprovided cement concrete foundation complete
83Dismantling the existing pole above 6 m height with brackets, clamps,insulators, stay from the c.c. foundation and making the site clear by refilling thepits with excavated materials and bringing it to the ground level.
84Supplying and erecting CRCA powder coated corridor / passage light LEDfitting (4 feet) Max. 50W with high transitivity diffuser with system lumensoutput of Min. 6000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCTupto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs.at L70B50, including driver, with end caps on provided PVC Block / woodenboard with 3 years warranty.
85Supplying and erecting Electronic type cordless call bell erected on T.W.board having portable bell push working on 9V D.C. battery and (effectiverange upto 45 meter) bell on 250 V A.C. supply.
86Supplying and erecting electronic type driver for indoor LED upto 24W fixturessuitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%
87Erecting the departmentally supplied WP LED street light / flood light fittingupto 80W.
88Erecting departmentally supplied LED street light/ flood light fitting above80 to 150W .
89Dismantling the existing W.T. fluorescent fitting/ S.V./ M.V. / M.H. lamp/LED fitting from pole with brackets complete.
90Erection of departmentally supplied 4ft / 2ft LED fitting on PVC blockconnected with necessary leads complete
91Supplying and erecting integrated LED street light fitting 18 to 22W IP65 &IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W,CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification No FGODF/FLS2.
92Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W,CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, includingdriver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
93Supplying and erecting integrated LED street light fitting 60W IP65 & IK08class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including drivercomplete with 3 Years warranty as per specification No FG-ODF/FLS2
94Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including drivercomplete with 3 Years warranty as per specification No FG-ODF/FLS2.
95Supplying and erecting integrated LED street light fitting 100-110W IP65 &IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W,CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, includingdriver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
96Supplying and erecting integrated LED flood light fitting Max. 100W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2
97Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowlsuitable for upto 12W LED Lamp on provided pipe as per specification No. FGODF/GLT
98Supplying and erecting Street light bracket for erection of Single fitting madefrom 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC
99Supplying and erecting Street light bracket for erection of Double fittingmade from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole capof 300 mm length 100 mm dia duly welded as per specification no. FGBKT/BPC
100Supplying and erecting Street light bracket for erection of Single fitting ontubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe alongwith pole cap of 125mm dia 600 mm long duly welded as per specification no.FG-BKT/BPC
101Supplying and erecting electronic type Driver for Outdoor LED Fittings upto25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
102Supplying and erecting electronic type Driver for Outdoor LED Fittings 26W-45W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%
103Supplying and erecting electronic type Driver for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%
104Supplying and erecting integrated LED flood light fitting Max. 70W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2
105Supplying and erecting electronic type Driver for Outdoor LED Fittings 76W-100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%
106Supplying and erecting electronic type Driver for Outdoor LED Fittings 101W-150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
107Supplying and erecting integrated LED flood light fitting Max. 70W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
108Supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “ON” and switching“OFF” street light as per daily sunset and sunrise respectively automaticallyhaving 4 digit LED continuous time display, relay output 230 V / 10A with 10hrs. battery backup and manual over drive facility capable to drive differentcapacity contactors timer erected in provided M.S. box
109Supplying and erecting electronic type Driver for Outdoor LED Fittings 76W-100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%
110Supplying and erecting electronic type Driver for Outdoor LED Fittings 101W-150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%
111Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 / E-27 base
112Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz,1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs.based on Insulated Gate Bipolar Transistor (IGBT) technology complete as perspecification no. AP-INV
113Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixedmagnetic setting with provided leads, provision for installation of shunt/UV/tripalarm contact. MCCB with phase barriers on both sides, insulation withstandcapacity 800V, no line-load bias in provided enclosure/panel as per specificationno. SW-SWR/MCCB
114Supplying and erecting porcelain base iron clad cut out HC type 415V, 32Aerected on polished wooden block
115Supplying & erecting HRC fuse cartridge 415V, 400A
116Supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) Aerial bunchedaluminium cable along with necessary accessories for LT distribution onprovided LT pole as per specification no. OH-CBL/ABC
117Supplying and erecting G.I. stay set for poles, including loop insulators atinaccessible height with anchor plate 300x300x6mm., straining screws, G.l. staywire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected inprovided cement concrete foundation complete.
118Dismantling the existing pole above 6 m height with brackets, clamps,insulators, stay from the c.c. foundation and making the site clear by refilling thepits with excavated materials and bringing it to the ground level.
119Supplying and erecting of isi mark insulation tape
120Supplying and erecting of isi mark nutbolts
121Supplying and erecting of isi mark tester
122Supplying and erecting of isi mark led zero bulb
123Supplying and erecting of isi mark led zero bulb holder
124Supplying and erecting fault clearing on street light conductor
125Supplying and erecting of AC servicing
126Supplying and erecting of filter servicing
127Supplying and erecting of batery servicing with water change
128Supplying and erecting of RO membrane for filter
129Supplying and erecting isi mark extension box

AI Tender Summary

OUR REF NO 42566995
AUTHORITY Local Bodies
TENDER VALUE 21 Lakhs
LAST DATE 04-03-2024
Authority
Authority Name Directorate Of Municipal Administration
Work Description Tender For Yearly Maintenance And Repair Of Street Lights In Indapur Municipal Council On Annual Contractual Basis, Erection Of New Street Lights And Other Ancillary Works As Required- 1 Supplying & Erecting Mains With 2X10 Sq.Mmf.R Copperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw 2 Supplying & Erecting Mains With 2X6 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw 3 Supplying & Erecting Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw 4 Supplying And Erecting Mains With Wp 2 X 6 Sq. Mm. 1100 V Grade Aluminiumpvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swgg.I. Binding Wire. 5 Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminiumpvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swgg.I. Binding Wire 6 Supplyinganderectingisi Mark G.I. Pipepole ‘B’ Grade80 Mm Dia 6 M Longwith Pole Cap, Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Gip 7 Supplying And Erecting Rolled Steel Joist ( Girder ) Pole 125 X 70 Mm ( 13.3 Kg / M ) With Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Rsj 8 Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm Diawith 4.5 X 3.65 X 3.25 Mm Thickness ( 5+2+2 M ) Length Respectively And Total9 M Long With Pole Cap, Base Plate In Provided Foundation ( Weight 113 Kg ) As Perspecification No 9 Providing & Erecting 7 M High ( Clear Height ) Galvanised Octagonal Pole Withfoundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Providedfoundation As Per Specification No. Oh-Pl / Opl 10 Providing & Erecting 9 M High ( Clear Height ) Galvanised Octagonal Pole Withfoundation Bolts Having Bottom Of 155 Mm A / F, Top 70 Mm A / F On Providedfoundation As Per Specification No. Oh-Pl / Opl 11 Providing And Erecting Galvanised 1000Mm Single Arm Sword Type Bracket With Frp Domeand Ball As Per Specification No. Oh-Pl / Pbkt 12 Providing And Erecting Galvanised 1000Mm Double Arm Sword Type Bracket With Frp Domeand Ball As Per Specification No. Oh-Pl / Pbkt 13 Supplying & Erecting Ms Pole Bracket For Guarding / Lt Oh Line, Fabricatedfrom Angle Iron 50X50x6mm And 1100Mm Long For Necessary Nos. Ofprovided Insulators, And Erecting On Pole With 50X6mm Clamp Complete As Perspecification No. Oh -Pl / Bkt 14 Supplying And Erecting G.I. Pipe ‘C’ Class Erw 25 Mm Dia With Necessary Fittings Complete As Per Specification No. 15 Supplying And Erecting G.I. Pipe ‘C’ Class Erw 50 Mm Dia With Necessaryfittings Complet 16 Supplyinganderectingpole Clamp Madefrom50 X 6 Mmms Flat For Pole Or Pipe, Postcompleteerected With 15 Mm Bolts And Nuts, Complete Duly Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint. 17 Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results Asper Specification No. Ea-Ep 18 Providingpipetype Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rodcomplete With All Materials As Per Specification No. Ea-Ep 19 Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm With Funnel With A Wire Mesh For Watering And Brick Masonry Block C.L. Cover Complete With All Materials, Testing & Recording The Results As Per 20 Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( Above 6 M To 9 M Poles ) 21 Making M- 20 Grade Reinforced Cement Concrete Foundation By Consideringthe Safe Soil Bearing Capacity At Site As 10 T / Sq.M At 1.5 M Depth Including Supplyof Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Oftemplate, Duly Plastered As Per Design Complete ( For 9M & 10M High Octagonal / Conical Gi Pole ) 22 Making M- 20 Cement Concrete Foundation By Considering The Safe Soilbearing Capacity At Site As 10 T / Sq. M At 2 M Depth Including Excavation And Fixingprovided Nut Bolts With The Help Of Template, Duly Plastered As Per Designcomplete ( For 12.5 M Raising Lowering High Mast ) 23 Painting Of Steel Tubular / Rail / Rsj Pole Above 6.0 M Length Along Withstreet Light Pole Brackets, Clamps Etc By Scrapping The Existing Paint Completeas Per Specification No Cw -Ptg / Ptp. 24 Supplying, Erecting & Marking Dpmcb 6A To 32A, C-Series With Rated Short -Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Perspecification No. Sw-Swr / Mcb 25 Supplying, Erecting & Marking Dpmcb 6 A To 32 A B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 26 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 63Aerected On Polished Wooden Block. 27 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 100Aerected On Polished Wooden Block. 28 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 200Aerected On Polished Wooden Block 29 Supplying, Erecting & Marking Tpmcb 40A To 63A, With Rated Short - Circuitbreaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specificationno. Sw-Swr / Mcb 30 Supplying, Erecting & Marking Fpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 31 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 32 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 33 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductorcomplete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 34 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 35 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 35 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 70 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 36 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3 Core 4 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Cu 37 Supplying & Erecting D.O.L Starter Suitable For 415 V, 3 Phase 50 Cycles With Novolt Coil And Overload Element With Necessary Materials And Connected To Supplyup To 7.5 H.P. 38 Supplying & Erecting Fully Automatic Star / Delta Starter Suitable For 12.5 H.P To 15 H.P. For 3 Phase Squirrel Cage Motor Totally Enclosed With Overload And No Volt Relay Complete Erected On Provided Angle Iron Frame 39 Supplying & Erecting Frp Box Of Size 300Mm X 200Mm X 125 Mm, 2.7 Mmthick Complete On Pole / Wall As Per Specification No. Cb-Sb 40 Supplying & Erecting Frp Box Of Size 250Mm X 200Mm X 100 Mm, 2.7 Mm Thick Complete On Pole / Wall As Per Specification No. Cb-Sb 41 Supplying Andlaying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 90 Mmoutside Dia. Double Wall Corrugatedpipes ( Dwc ) Ofhdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. 42 Supplying & Erecting Crimping Type Copper Lugs For Cable 25 Sq. Mm. Complete As Per Specification No. Cb-Cl / Cu 43 Supplying & Erecting Crimping Type Copper Lugs For Cable120 Sq. Mm. Completeas Per Specification No. Cb-Cl / Cu 44 Supplying And Erecting Metal Work In Crca Sheet Including Iron Work For Supports With Fabrication Of Boxes, Panel Boards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment And Duly Powder Coated Or Painted With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete. ( Meter Pannel Box ) 45 Point Wiring For Light / Bell Hybrid Type ( Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls ) In Min 20 Mm Pvc Conduit / Casing N Capping With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wgpw / Hw 46 Point Wiring For Ceiling Fan ( Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls ) In Min 20 Mm Pvc Conduit / Casing Ncapping With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories 47 Supplying And Erecting Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Anyother Places. As Per Specification No: Wg-Ma / Bw 48 Supplying And Erecting Modular Type ( Two Module ) Electronic Step Regulator For Fan, Duly Erected On Provided Plate And Box With Wiring Connections Complete. 49 Supplying And Erecting Regular / Standard Model Ceiling Fan Of 1400Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 50 Supplying And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 Rpm. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Speed Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 51 Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E’ Class Insulation. 52 Supplying And Erecting Integrated Led Street Light Fitting 23 To 25W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 2300 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3Years Warranty As Per Specification No Fg-Odf / Fls2. 53 Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 54 Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08class Having Single Piece Pressure Die-Cast Aluminium Housing, Having Systemlumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuiltsurge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Drivercomplete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 55 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 56 Supplying And Erecting Integrated Led Flood Light Fitting Max. 120W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min.14500 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 57 Erecting Departmentally Supplied Led Street Light / Flood Light Fitting Above80 To 150W . 58 Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B’ Classg.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Diaduly Welded With Provided Leads As Per Specification No. Fg-Bkt / Bpc 59 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W-75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 60 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 151W-200W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 61 Supplying And Erecting T8 Fluorescent Tube Day Light 600Mm, 18 W 62 Supplying & Erecting Ready To Use Retrofit T8 Led 18 / 20 Tube Light With Polycarbonate Body, Heat Sink, Integrated Hf Electronic Driver Complete &Compatible To T8 / T12 Led Luminaire By Disconnecting Starter & Ballast If Necessary. 63 Supplying And Erecting Flush Type Shockproof Plug Socket 6A & 16A ( 6 Pin ) With 16A Switch Combined With Indicator Lamp And Fuse With Gang Box Onwooden Board 64 Supplying And Erecting Modular Type 32A, Dp Key Tag Switch With Key Tag, Duly Erected On Provided Plate And Box With Wiring Connections Complete 65 Supplying & Erecting 18W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base 66 Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 700Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs. Based Oninsulated Gate Bipolar Transistor ( Igbt ) Technology Complete As Perspecification No. Ap-Inv 67 Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 1400 To 1600Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs.Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Complete As Perspecification No. Ap-Inv 68 Supplying, Erecting, Testing And Commissioning Of Single Phase Input & 1 Phaseoutput 1 Kva Capacity Online Pure Sine Wave Ups, With Backup Time Of .......Hrs. Pwm & Igbt Based, With 0.8 To Unity Output Pf Complete With Allprotections As Per Specification No. Ap-Ups 69 Supplying And Erecting 12V / 200Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete 70 Supplying And Erecting 12V / 150Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete. 71 Providing Servicing Of 1 / 1.5 / 2 / 3 Tr Capacity Split / Window Airconditioning Unit With All Necessary Material. Job Includes Checking Ofperformance Of Unit, Cleaning Of Filters Of Indoor Unit, Cleaning Of Outdoor Unitwith Blower, Checking Of Electrical Connection Of Indoor As Well As Outdoor Unitcomplete And Submitting Report To Engineer Incharge. 72 Providing Annual Comprehensive Maintenance Contract For 1.5Trsplit / Window Air Conditioning Unit Complete As Per Terms And Conditions. Jobincludes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheetmetal Work And Plastic Material 73 Providing Brazing Pipes And Checking Leakages In The Split / Window Unitduly With Dry Nitrogen Pressure, Complete. 74 Providing Replacement Of Unserviceable Pcb For Ac Unit Upto 3Tr Capacity 75 Supplying And Erecting Quartz Electronic Time Switch Having 24 Hour Dial Towork On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteriesto Run The Time Switch On Failure Of Supply Having Switch Contact Rating Up To 16Ato Use Independently Or In Conjunction With Contactor 76 Supplying And Erecting Four Pole Power Contactor 430 V, 40 A For Time Switchcomplete Erected On Provided Wooden Block / Box, With Necessary Materials 77 Supplying And Erecting Programmable Digital Almanac Timer Microcontrollerbased With Real Time Clock To Operate On Derived Switching “On” And Switching“Off” Street Light As Per Daily Sunset And Sunrise Respectively Automaticallyhaving 4 Digit Led Continuous Time Display, Relay Output 230 V / 10A With 10Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Differentcapacity Contactors Timer Erected In Provided M.S. Box 78 Supplying And Erecting Static Energy Meter With 240V 50 Hz. Ac Supply 10To 60 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, ( Measuring Anddisplay Kwh, Kvah, V, I, Pf, Frequency, Kw, Kva, Six Months History Ofenergy & Md In Kw & Kva ) With Transparent Hinge Type Box Completeerected On Polished Teak Wood Board Duly Wired With Required Size Ofweather Proof Pvc Wires Duly Tested By Electric Supply Company 79 Supplying & Erecting Crimping Type Aluminium Lugs For Cable 240 Sq Mmcomplete As Per Specification No. Cb-Cl / Al 80 Supplying And Erecting All Aluminium Stranded Conductors 7 / 2.21 Mm.Complete. ( Gnat ) ( 73.77Kg / Km ) As Per Specification No. Oh-Con / Aac 81 Supplying And Erecting 3 Phase 4 Core 35 Sq.Mm. ( 3X35+1X25 ) Aerial Bunchedaluminium Cable Along With Necessary Accessories For Lt Distribution Onprovided Lt Pole As Per Specification No. Oh-Cbl / Abc 82 Supplying And Erecting G.I. Stay Set For Poles, Including Loop Insulators Atinaccessible Height With Anchor Plate 300X300x6mm., Straining Screws, G.L. Staywire 7 / 10 Swg, G.L. Stay Rod 20Mmx1.8M Length And Pole Clamps Duly Erected Inprovided Cement Concrete Foundation Complete 83 Dismantling The Existing Pole Above 6 M Height With Brackets, Clamps, Insulators, Stay From The C.C. Foundation And Making The Site Clear By Refilling Thepits With Excavated Materials And Bringing It To The Ground Level. 84 Supplying And Erecting Crca Powder Coated Corridor / Passage Light Ledfitting ( 4 Feet ) Max. 50W With High Transitivity Diffuser With System Lumensoutput Of Min. 6000 Lumens , Min. Efficacy Of 120 Lumen / W, Cri>80, Cctupto 6500K, Beam Angle Of 120 Deg., Ripple<5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs.At L70b50, Including Driver, With End Caps On Provided Pvc Block / Woodenboard With 3 Years Warranty. 85 Supplying And Erecting Electronic Type Cordless Call Bell Erected On T.W.Board Having Portable Bell Push Working On 9V D.C. Battery And ( Effectiverange Upto 45 Meter ) Bell On 250 V A.C. Supply. 86 Supplying And Erecting Electronic Type Driver For Indoor Led Upto 24W Fixturessuitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 87 Erecting The Departmentally Supplied Wp Led Street Light / Flood Light Fittingupto 80W. 88 Erecting Departmentally Supplied Led Street Light / Flood Light Fitting Above80 To 150W . 89 Dismantling The Existing W.T. Fluorescent Fitting / S.V. / M.V. / M.H. Lamp / Led Fitting From Pole With Brackets Complete. 90 Erection Of Departmentally Supplied 4Ft / 2Ft Led Fitting On Pvc Blockconnected With Necessary Leads Complete 91 Supplying And Erecting Integrated Led Street Light Fitting 18 To 22W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 1800 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fgodf / Fls2. 92 Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 93 Supplying And Erecting Integrated Led Street Light Fitting 60W Ip65 & Ik08class Having Single Piece Pressure Die-Cast Aluminium Housing, Having Systemlumens Output Of Min. 6600 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuiltsurge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Drivercomplete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 94 Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08class Having Single Piece Pressure Die-Cast Aluminium Housing, Having Systemlumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuiltsurge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Drivercomplete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 95 Supplying And Erecting Integrated Led Street Light Fitting 100-110W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 11000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 96 Supplying And Erecting Integrated Led Flood Light Fitting Max. 100W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min. 12000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 97 Supplying And Erecting Gate / Garden Light Fitting With 200Mm Dia. Glass Bowlsuitable For Upto 12W Led Lamp On Provided Pipe As Per Specification No. Fgodf / Glt 98 Supplying And Erecting Street Light Bracket For Erection Of Single Fitting Madefrom 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fg-Bkt / Bpc 99 Supplying And Erecting Street Light Bracket For Erection Of Double Fittingmade From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Capof 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fgbkt / Bpc 100 Supplying And Erecting Street Light Bracket For Erection Of Single Fitting Ontubular Welded Pole With 40 Mm. Dia 1.0 M. Length “B” Class G.I .Pipe Alongwith Pole Cap Of 125Mm Dia 600 Mm Long Duly Welded As Per Specification No.Fg-Bkt / Bpc 101 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto25w Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 102 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 26W-45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 103 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W-75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 104 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 105 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 76W-100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 106 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 101W-150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 107 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 &Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumensoutput Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cctupto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surgeprotection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 108 Supplying And Erecting Programmable Digital Almanac Timer Microcontrollerbased With Real Time Clock To Operate On Derived Switching “On” And Switching“Off” Street Light As Per Daily Sunset And Sunrise Respectively Automaticallyhaving 4 Digit Led Continuous Time Display, Relay Output 230 V / 10A With 10Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Differentcapacity Contactors Timer Erected In Provided M.S. Box 109 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 76W-100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 110 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 101W-150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 111 Supplying & Erecting 18W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base 112 Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 1400 To 1600Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs.Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Complete As Perspecification No. Ap-Inv 113 Providing & Erecting 3 Pole Mccb, 415 V, 100A, Rated Short-Circuit Breakingcapacity 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Fixedmagnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Tripalarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstandcapacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specificationno. Sw-Swr / Mccb 114 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 32Aerected On Polished Wooden Block 115 Supplying & Erecting Hrc Fuse Cartridge 415V, 400A 116 Supplying And Erecting 3 Phase 4 Core 35 Sq.Mm. ( 3X35+1X25 ) Aerial Bunchedaluminium Cable Along With Necessary Accessories For Lt Distribution Onprovided Lt Pole As Per Specification No. Oh-Cbl / Abc 117 Supplying And Erecting G.I. Stay Set For Poles, Including Loop Insulators Atinaccessible Height With Anchor Plate 300X300x6mm., Straining Screws, G.L. Staywire 7 / 10 Swg, G.L. Stay Rod 20Mmx1.8M Length And Pole Clamps Duly Erected Inprovided Cement Concrete Foundation Complete. 118 Dismantling The Existing Pole Above 6 M Height With Brackets, Clamps, Insulators, Stay From The C.C. Foundation And Making The Site Clear By Refilling Thepits With Excavated Materials And Bringing It To The Ground Level. 119 Supplying And Erecting Of Isi Mark Insulation Tape 120 Supplying And Erecting Of Isi Mark Nutbolts 121 Supplying And Erecting Of Isi Mark Tester 122 Supplying And Erecting Of Isi Mark Led Zero Bulb 123 Supplying And Erecting Of Isi Mark Led Zero Bulb Holder 124 Supplying And Erecting Fault Clearing On Street Light Conductor 125 Supplying And Erecting Of Ac Servicing 126 Supplying And Erecting Of Filter Servicing 127 Supplying And Erecting Of Batery Servicing With Water Change 128 Supplying And Erecting Of Ro Membrane For Filter 129 Supplying And Erecting Isi Mark Extension Box
Basic Detail
Tender No IMC/Light/01/2024-25
Bidding Type Tender
Location
City indapur
State Maharashtra
Key Dates
Publish Date 27 Feb 2024
Submission Date 04 Mar 2024
Open Date 05 Mar 2024
Finance
Tender Value 21 Lakhs
Tender Fee 5000
EMD 21000
Exemption Not Available
Document List
3b94653f-e44a-46ec-b6cf-c55b4512f0a2.html
Affidavit.pdf
b1.pdf
BOQ_1781378.xls
tc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 27, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 04, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 05, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3b94653f-e44a-46ec-b6cf-c55b4512f0a2.html

pdf

Affidavit.pdf

pdf

b1.pdf

xls

BOQ_1781378.xls

pdf

tc.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders